Raypak XFYRE 850 User Manual

up to 99%  
Efficiency!  
Can be vented with PVC  
MBTU Models  
300 400 500 700 850  
CSA Verified lead Content  
Ultra Low Emissions  
Less Than .25% Pb  
Model 850  
Model 300  
1. Water Inlet  
5. Air Fuel Ratio Gas Valve  
12. Direct Spark Ignition  
As low as 50°F entering. All copper and brass factory  
installed vertical plumbing connections. Vertical  
plumbing allows boilers to be installed side by side or  
in tight places if need be. Male NPT connections.  
XFyre uses a German, precision manufactured, main  
gas valve considered by most to be second to none.  
This high tech gas valve works in perfect unison with  
the combustion air blower. The result is smooth and  
quiet light-offs while delivering a 5:1 turn down.  
With this much flexibility, XFyre is the right boiler for  
almost any size job.  
XFyre's state-of-the-art combustion control system  
utilizes the finest dual electrode igniter to start the  
combustion cycle. After ignition, the spark rod also  
acts as a second flame sensor.  
2. Water Outlet  
All copper and brass factory installed vertical plumb-  
ing connections. Male NPT connections.  
12a. Flame Sense Electrode  
After a call for heat, a seperate flame electrode moni-  
tors flame rectification. This helps to ensure proper  
carry over while also constantly monitoring the flame  
over 50 times every second.  
6. Intake Air Filter  
Every XFyre comes standard with a front access,  
3. Low Voltage Wiring Board  
Allows easy front access to thermostat connections,  
Outdoor sensor, DHW sensor, Alarm contacts and BMS  
input signal (0-10VDC). Built-in cascade control using  
CAT 3 or CAT 5 computer network cables to connect  
with the communication bus between boilers. Every  
unit comes factory equipped with Cascade control.  
Simply remove the front door for quick access and  
daisy chain the boilers together.  
removable Merv 8 media, combustion air filter.  
13. Internal Tru-SealT Connection  
7. Manual Reset High Limit  
Allows the XFyre to be direct vented up to 200 com-  
bined equivalent feet (vent and air intake) in a hori-  
zontal or vertical vent system.  
8. Condensate Trap  
The XFyre has a built-in condensate trap located at  
the rear of the unit. The trap and the overfill conden-  
sate sensor are accessible through their own access  
panel.  
14. Smart Blower Technology  
Utilizing a whisper quiet, all metal, technologically  
advanced combustion blower. Air and fuel are mixed  
precisely by the computer control center.  
4. Control Cover  
Helps prevent sun damage to the LCD display and  
9. Vent Switch  
protects the control panel from dust, dirt and water.  
Senses possible obstructions in the flue vent pipe.  
15. Mounting Feet  
Built-in mounting feet located right under the center  
of gravity allows for quick and easy Tapcont anchor-  
ing.  
4a. Control Interface  
10. Flow Switch  
Easy to use microprocessor control with a 2x20 LCD  
scrolling display. Monitor flame strength(mA), fan  
speed (RPM), BMS input signal (0-10V), sensor temps and  
setpoints. Built-in outdoor reset feature saves energy-  
requires optional outdoor air sensor. Control also pro-  
vides indirect priority function. Full diagnostic control  
constantly monitoring 18 events. Fault code history  
records the last 10 fault events and can be recalled to  
help with troubleshooting. Well thought out  
ergonomic control pad gives tactile feedback to the  
user. No need to second guess your actions, wonder-  
ing if you have engaged the buttons or not. The user  
is reassured with a tactile pop every time a button is  
successfully toggled. Everything you need from set-up  
to service is at your fingertips, and all in one location.  
The XFyre keeps its flow switch safe and dry inside  
the cabinet, which protects it during shipping and in  
the boiler room.  
16. Weather-Proof Jacket  
Heavy gauge galvanized steel with a UV-resistant  
Polytuf powder coat finish is impervious to weather  
and corrosion. Raypak has one of the finest, top-of -  
the-line powder coat systems on the west coast  
regardless of industry. We laugh at a 1000 hour salt  
spray test. Independent test documentation available  
upon request.  
11. “Duo” Style Heat Exchanger  
The XFyre uses a combined 316L stainless steel pri-  
mary and secondary heat exchanger. Weld-sealed  
technology eliminates gaskets and o-rings. Special  
glycol is not required for hydronic applications. ASME  
Section IV constructed and stamped. National Board  
registered.  
Think Raypak  
Think Green  
3
Xtreme Access  
The XFyre is purpose built for the  
contractor and service professional.  
7
4
8
Completely serviceable from the front, top and both sides!  
1. Flue Outlet  
Category IV- PVC, CPVC and Stainless steel certified.  
The XFyre ships PVC ready, no extras to purchase!  
5. Direct Vent Capability  
8. Inlet and Outlet Connections and Flow Switch  
The vertical inlet and outlet connections are all copper  
and brass fitted with male pipe thread connections.  
The flow switch is fully contained within the cabinet,  
protecting it from the elements and boiler room  
mishaps. Servicing of the Flow switch can be done  
from the top or left side.  
Every XFyre is direct vent capable. By installing an  
optional combustion air pipe adapter, your XFyre is  
ready for direct vent. For factory installation, order  
(option D-21) TruSealT at time of order.  
2. High Voltage Wiring Box  
120VAC main incoming power connections. Boiler  
pump wiring and DHW pump wiring. Alarm power  
out.  
6. Rating Plate Location  
9. Removable Air Filter  
7. Gas Valve and Boiler Control  
3. Gas Inlet  
Simple front access; just remove the front door. The fil-  
ter just slides right out for quick and easy inspection  
and replacement. The high capacity filter is rated  
MERV 8.  
Raypak uses German-made, high quality Dungs gas  
valves, considered the finest modulating gas valves  
produced today. To the right of the gas valve is the  
boiler computer control center, which always keeps the  
blower, gas valve, direct spark ignition and flame  
supervision in perfect harmony.  
The XFyre will operate at 100% full rate with gas pres-  
sures as low as 4.0”w.c.  
4. Condensate Drain and Trap  
3/4”-NPT PVC connection for condensate removal.  
Inset photo shows condensate trap, overfill sensor and  
pressure switch for the flue. Raypak offers optional  
condensate neutralizer kits (option Z-12) that can be  
plumbed between the heater and the drain.  
1
9
Remove Front Door  
Loosen wing-nuts  
FRONT ACCESS INTAKE AIR FILTER  
Pullout filter media  
4
Xtremely Small Footprint  
Dimensions (in.)  
Foot-  
Print  
Ship  
Weight  
(lbs.)  
Model  
Amps*  
F
A
E
G
H
T
V
K
Flue Ø  
2
(ft )  
Mounting  
Length  
NPT  
NPT  
C/A Ø  
300  
400  
500  
700  
850  
28 - 1/4  
30 - 3/4  
37 - 1/4  
47 - 3/4  
54 - 1/4  
16 - 1/2  
16 - 1/2  
16 - 1/2  
28  
27 - 9/16  
29 - 3/4  
36 - 1/4  
47 - 1/16  
53 - 9/16  
3/4  
1
1
1 - 1/4  
1 - 1/4  
1 - 1/2  
4
4
4
6
6
4
4
4
6
6
3
3
3
410  
465  
505  
550  
580  
4.3  
4.7  
5.7  
7.3  
8.3  
3
4
4
5
5
2
2
2
2
19 - 3/8  
19 - 3/8  
28  
Ratings shown are for elevations up to 10,000 feet. For installations at elevations above  
2,000 feet, derate may apply, please consult the factory for additional instructions.  
*Current Draw is for heater only.  
(Supply breaker must have delayed trip.)  
Boiler  
Efficiency  
Water Heaters  
MBTUH  
Input  
MBTUH  
Input  
Minimum  
Model  
Input  
Output  
Output  
Efficiency  
300  
400  
500  
700  
850  
300  
399  
500  
700  
850  
282  
375  
470  
658  
799  
94%  
94%  
94%  
94%  
94%  
300  
399  
500  
700  
850  
285  
379  
475  
665  
808  
95%  
95%  
95%  
95%  
95%  
60  
80  
100  
140  
170  
Heater  
Side  
Certified  
Service  
Water Heater Pump Sizes  
Medium  
XFyre  
Minimum  
Minimum  
Soft  
Amps  
Hard  
HP Amps  
Model  
Front  
Rear  
Right  
Left  
Top  
Floor  
Vent  
24”  
24”  
0”  
0”  
12”  
0”  
24”  
24”  
0”  
0”  
24”  
---  
HP  
HP  
Amps  
300  
400  
500  
700  
850  
1/8  
1/8  
1/4  
1/2  
1/2  
1.3  
1.3  
5.7  
6.9  
6.9  
1/4  
1/2  
1/2  
1
5.7  
6.9  
6.9  
14.0  
14.0  
Do not use when  
hardness exceeds  
15 grains per gallon  
1
1”  
---  
Note: Current draw (Amps) is for pump only  
Water hardness grains per gallon  
*Do not install on carpeting  
Note: Local codes may require increased clearances  
Soft = 0-4 • Medium = 5-15 • Hard = 16-25  
Water above 15gpg requires water softener.  
5
Xtremely Easy to Wire  
120VAC Wiring Center  
The XFyre’s 120VAC wiring center is located on the rear  
of the boiler. All incoming line voltage and pump wiring  
are contained away from the 24v control wiring. Wiring  
the boiler is simple and straight forward.  
Low Voltage Wiring Center  
Just like its big brother the XTherm, the XFyre has a  
separate front mounted wiring center for all of the  
low voltage connections. This makes thermostat, water  
sensor, 0-10VDC BMS, and alarm contacts a breeze to  
set up. No more guessing where the contact points  
are buried in the boiler. Built-in cascade control using  
CAT 3 or CAT 5 computer network patch cables to  
connect with the communication bus between boilers.  
Simply remove the front door for quick access.  
120VAC Wiring Center  
(rear of boiler)  
Low Voltage  
Wiring Center  
Hydronic Boiler  
Rates Of Flow And Pressure Drops  
XFyre  
20°F  
30°F  
40°F  
Minimum Flow*  
Maximum Flow  
Model  
DP  
DP  
DP  
DP  
DT  
DP  
DT  
GPM  
GPM  
GPM  
GPM  
GPM  
300  
400  
500  
700  
850  
28  
38  
47  
66  
80  
17  
18  
16  
30  
40  
19  
25  
31  
44  
53  
8
7
7
13  
17  
14  
19  
24  
33  
40  
5
4
4
7
9
14  
19  
24  
33  
40  
5
4
4
7
9
40  
40  
40  
40  
40  
36  
47  
56  
70  
80  
28  
29  
23  
34  
40  
16  
16  
17  
19  
20  
*Closed systems only  
Water Heater  
Water Hardness  
XFyre  
Soft  
(0-4 Grains Per Gallon)  
(5-15 Grains Per Gallon)  
(16-25 Grains Per Gallon)  
Hard  
Medium  
Model  
DT  
DP  
MTS SHL  
DT  
DP  
DT  
DP  
MTS SHL  
GPM  
GPM  
MTS SHL  
GPM  
300  
400  
500  
700  
850  
30 19  
30 25  
30 31  
30 44  
32 51  
8
7
7
13  
16  
1.5  
2
2
2
2
10  
8
8
17  
20  
24  
20  
20  
20  
24  
24  
38  
47  
66  
67  
17  
18  
16  
30  
28  
1.5  
2
2
2
2
19  
21  
20  
38  
36  
Do not use when hardness  
exceeds 15 grains per gallon  
MTS = Minimum Tube Size, inch.  
SHL = System Head Loss, ft (based on heater and tank placed no more than 5 ft apart).  
DT = Temperature rise,  
°F  
DP = Pressure drop through heat exchanger, ft  
Recovery Rates  
XFyre  
Model  
Temperature Rise (°F)  
20  
30  
40  
50  
60  
70  
80  
90  
100  
300  
400  
500  
700  
850  
1711  
2275  
2851  
3992  
4847  
1140  
1517  
1901  
2661  
3231  
855  
684  
910  
1140  
1597  
1939  
570  
758  
950  
1331  
1616  
489  
650  
815  
1140  
1385  
428  
569  
713  
998  
1212  
380  
506  
634  
887  
1077  
342  
455  
570  
798  
969  
1138  
1426  
1996  
2423  
6
Xtreme Control  
Boiler Control and  
On-Board Diagnostic Center  
Raypak’s XFyre comes equipped with a microprocessor control  
center that displays its information on a 2x20 character LCD  
display in plain English. All set-up and programming is done at  
this interface. Control monitors boiler system status including  
safeties, ignition faults and also stores up to 10 reported faults.  
The diagnostic center even monitors and reports the flame  
strength signal in microamps. Monitor blower speed, BMS  
input and all water and air sensors. A normally-open and nor-  
mally-closed dry contact alarm relay is provided.  
Outdoor Proven  
Raypak is no stranger to the outdoor environment. Our touchpad is 100% waterproof and has been proven and perfected on our  
pool products. No guesswork here, just one tough boiler ready to take on jobs that others have to walk away from.  
Diagnostic Information  
Safety Faults  
Low Water Flow  
Temper Blocking  
High Temperature  
Flue/Gas Pressure  
Supply Thermistor  
Return Thermistor  
Supply High  
Ignition Control Faults  
No Flame  
Flame Failure  
Flame When Off  
Fan Speed Error  
Condensate Full  
Outdoor Sensor  
Line Voltage  
Blocked Vent  
Low Water Level  
24 Volt Low  
Example Diagnostic Fault Report  
Xtreme Firing Rates  
Cascade up to 8 Boilers  
Deliver up to 6.8 Million BTU at a 40:1 turndown rate!  
The XFyre comes standard with a built-in Cascading Boiler Control. No other controls to buy, just daisy chain the units together  
with CAT 3 or CAT 5 computer network cables (not supplied) that plug into the front mounted communication bus on each unit  
(see low voltage wiring box opposite page). Designate a Cascade Master Boiler and set all the other boilers as Followers. It’s that sim-  
ple! The XFyre has built-in Lead-Lag control. This allows rotation of the starting boiler so all boilers in the system remain active  
and the run times remain equal on each unit. Rotation can even be programmed based on time, ensuring equal run times per  
unit.  
7
Water  
Heaters  
(Type WH)  
Boilers  
(Type H)  
ASME Section IV, National Board Registered, 160 PSI • H Stamp  
v
v
v
v
v
v
Heat Exchanger Tubes  
Stainless Steel  
• 316L Stainless Steel  
• CSA Verified AB-1953 CA low lead compliant  
Pressure Relief Valve  
(loose)  
• 60 PSI  
V
v
V
v
V
V
• 125 PSI  
• 30, 45, 75, 150 PSI  
Temperature & Pressure Gauge (Loose)  
Pump  
v
V
v
V
• 120V, Single-Phase  
Indoor/Outdoor Certified  
Vent Terminal  
v
V
V
v
V
V
• Outdoor  
• Through-the-Wall  
Fully-Enclosed Controls  
Combustible Floor Rated  
v
v
v
v
120V Power Supply  
On/Off Switch  
Programmable Pump Time Delay, Single-Phase • Included in Controller  
v
v
v
v
v
v
Terminal Block Connections  
(Front mounted)  
• Enable / Disable  
• 0-10 VDC Setpoint/Direct Drive Input  
v
v
v
v
LCD diagnostic display with 10-Event History (2x20 character display, reads in plain English)  
v
v
N/A  
v
v
V
Temperature Controller with 3 Water Sensors  
• (up to 5:1 Turndown)  
• Outdoor Reset Sensor  
Multiple Boiler Controller  
• TempTracker Mod+ Hybrid, up to 16 boilers/groups  
V
V
Direct Spark Ignition System  
• 1-try  
• 4-try  
V
v
V
v
High/Low Gas Pressure Switches  
Blocked Vent Switch  
High Limit Switch  
V
v
v
V
V
v
v
V
• Manual Reset, Fixed  
• Automatic Reset, Fixed  
Low Water Cut-Off, 24V  
Flow Switch  
• With Manual Reset and Test Buttons  
V
v
V
v
Modulating Combination Gas Valve  
Combustion Air Blower  
Additional Safety Valve  
v
v
V
V
v
v
V
V
• Motorized (externally mounted)  
• Solenoid (externally mounted)  
CSA-Certified Efficiency  
• 94% at Full Fire  
• 95% at Full Fire  
N/A  
v
v
N/A  
• 99% at Part Load  
v
v
V
v
V
v
v
V
v
v
V
v
V
v
v
V
Air Filter  
TruSeal Direct-Vent  
Alarm Contacts  
CSD-1 / GE GAP Control System  
Low NOx  
• Meets all current requirements  
Condensate Drain and Trap  
Condensate Neutralizer  
v v = Standard  
V V = Optional  
© 2009-2010 Raypak, Inc.  
Cat. No. 1000.22B Effective: 07-15-10 Replaces: 02-15-10  

Pyramid Car Audio PB310SX User Manual
Planar Systems Car Video System pl191m User Manual
Panasonic HDC SX5P User Manual
Panasonic GP MS112 User Manual
Milwaukee 9565 User Manual
Life is good Blu Ray Disc Player BP330 User Manual
Kodak IMAGE SENSOR KAF 10500 User Manual
Kenwood RC D10 User Manual
Kaidan KiWi+ User Manual
JVC KD R310 User Manual