York Air Conditioner R 410a User Manual

528194-YTG-F-1210  
®
Description  
TECHNICAL GUIDE  
R-410A  
ASHRAE 90.1 COMPLIANT  
®
®
YORK Predator units are convertible single packages with a  
common footprint cabinet and common roof curb for all 6-1/2  
through 12-1/2 ton models. All units have two compressors with  
independent refrigeration circuits to provide 2 stages of cooling.  
The units were designed for light commercial applications and  
can be easily installed on a roof curb, slab, or frame.  
ZF SERIES  
6-1/2 - 12-1/2 TON  
60 Hertz  
®
All Predator units are self-contained and assembled on rigid  
full perimeter base rails allowing for 3-way forklift access and  
overhead rigging. Every unit is completely charged, wired,  
piped, and tested at the factory to provide a quick and easy field  
installation.  
All units are convertible between side and down airflow.  
Independent economizer designs are used on side and down  
discharge applications, as well as all tonnage sizes.  
®
Predator units are available in the following configurations:  
cooling only, cooling with electric heat, and cooling with gas  
heat. Electric heaters are available as factory-installed options  
or field-installed accessories.  
All units provide constant supply air volume. A variable air  
volume (VAV) option, featuring a variable frequency drive, is  
available on 6-1/2 through 12-1/2 ton models.  
ZF 6-1/2 THROUGH 10 TON  
Tested in accordance with:  
ZF12-1/2 TON  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
 
528194-YTG-F-1210  
Nomenclature  
®
6.5-12.5 Ton York Model Number Nomenclature  
Z F 090 N10 A 2 A AA 5 0 1 2 4 A  
Product Style  
Product Category  
Z = A/C, Single Pkg., R-410A  
A = Style A  
B = Style B  
C = Style C  
Configuration Options (not required for all units)  
These four digits will not be assigned until a quote is requested, or an order placed.  
Product Identifier  
F = 11.2 + EER A/C  
SS Drain Pan  
CPC Controller, DFS, APS  
Johnson Controller UNT 1126 (N2 protocol), DFS, APS  
Honeywell Controller, DFS, APS  
Novar Controller, DFS, APS  
Nominal Cooling Capacity  
Simplicity IntelliComfort Controller  
078 = 6.5 Ton  
090 = 7.5 Ton  
102 = 8.5 Ton  
120 = 10.0 Ton  
150 = 12.5 Ton  
Simplicity IntelliComfort Controller w/Simplicity®LINC  
York Commercial Comfort System (YCCS) Rtu Controller  
Hot Gas Bypass (Standard on VAV, Optional on CV)  
Variable Air Volume, VFD (not available with factory installed BAS options)  
Variable Air Volume, VFD with Simplicity®LINC (not available with factory installed BAS options)  
Variable Air Volume, VFD and Manual Bypass  
(not available with factory installed BAS options)  
Heat Type and Nominal Heat Capacity  
C00 = Cooling Only. No heat installed  
Variable Air Volume, VFD and Manual Bypass with Simplicity®LINC  
(not available with factory installed BAS options)  
Variable Air Volume, VFD (BAS ready)  
Gas Heat Options  
Variable Air Volume, VFD and Manual Bypass (BAS ready)  
Variable Air Volume, VFD Ready (for customer-provided, field-installed drive)  
N10 = 100 MBH Output Aluminized Steel  
N15 = 150 MBH Output Aluminized Steel  
N20 = 200 MBH Output Aluminized Steel  
S10 = 100 MBH Output Stainless Steel  
S15 = 150 MBH Output Stainless Steel  
S20 = 200 MBH Output Stainless Steel  
Variable Air Volume, VFD Ready with Simplicity®LINC  
(for customer-provided, field-installed drive)  
2" Pleated filters  
4" Pleated filters  
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)  
Shipping Bag  
Electric Heat Options  
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned  
E09 = 9 KW  
E18 = 18 KW  
E24 = 24 KW  
E36 = 36 KW  
E54 = 54 KW  
Product Generation  
5 = Fifth Generation  
Additional Options  
AG = Coil Guard & Dirty Filter Switch  
Airflow  
AA = None  
AH = Phase Monitor, Coil Guard & Dirty Filter Switch  
RC = Coil Guard, Shipping Bag & American Flag  
TA = Technicoat Condenser Coil  
TJ = Technicoat Evaporator Coil  
TS = Technicoat Evaporator & Condenser Coils  
AB = Phase Monitor  
A = Std. Motor  
AC = Coil Guard  
AD = Dirty Filter Switch  
AE = Phase Monitor & Coil Guard  
AF = Phase Monitor & Dirty Filter Switch  
B = Std. Motor/Econo./Barometric Relief (Downflow  
Only)  
C = Std. Motor/Econo./Power Exhaust (Downflow Only)  
D = Std. Motor/Motorized Damper (Downflow Only)  
E = Std. Motor/Horizontal Economizer (No Baro.)  
F = Std. Motor/Slab Econo./Power Exhaust  
(Downflow Only)  
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be  
located in digits 15-18.  
G = Std. Motor/Slab Econo./Barometric Relief  
(Downflow Only)  
N = Hi Static  
Installation Options  
P = Hi Static/Econo./Barometric Relief  
(Downflow Only)  
Q = Hi Static/Econo./Power Exhaust  
(Downflow Only)  
R = Hi Static/Motorized Damper (Downflow Only)  
S = Hi Static/Horizontal Economizer (No Baro.)  
T = Hi Static/Slab Econo./Power Exhaust  
(Downflow Only)  
U = Hi Static/Slab Econo./Barometric Relief  
(Downflow only)  
A = No Options Installed  
B = Option 1  
C = Option 2  
D = Options 1 & 2  
E = Option 3  
F = Option 4  
G = Options 1 & 3  
H = Options 1 & 4  
J = Options 1, 2 & 3  
K = Options 1, 2, & 4  
L = Options 1,3 & 4  
M = Options 1, 2, 3, & 4  
N = Options 2 & 3  
P = Options 2 & 4  
Q = Options 2, 3, & 4  
R = Options 3 & 4  
S = Option 5  
Voltage  
2 = 208/230-3-60  
4 = 460-3-60  
5 = 575-3-60  
T = Options 1 & 5  
U = Options 1, 3, & 5  
V = Options 1, 4, & 5  
W = Options 1, 3, 4, & 5  
X = Options 3 & 5  
Y = Options 4 & 5  
Z = Options 3, 4 & 5  
Options  
1 = Disconnect  
2 = Non-Pwr'd Conv. Outlet  
3 = Smoke Detector S.A.  
4 = Smoke Detector R.A.  
5 = Pwr'd Conv. Outlet  
Johnson Controls Unitary Products  
3
 
528194-YTG-F-1210  
System Protection - Suction line freezestats are supplied  
on all units to protect against loss of charge and coil frosting  
when the economizer operates at low outdoor air  
Features and Benefits  
Standard Features  
temperatures while the compressors are running. Every unit  
has solid-core liquid line filter-driers and high and low-  
pressure switches. Internal compressor protection is  
standard on all compressors. Crankcase heaters are  
standard on reciprocating compressors. Scroll compressors  
do not require crankcase heaters. Phase Monitors are  
standard on units with scroll compressors. This accessory  
monitors the incoming power to the unit and protects the  
unit from phase loss and reversed phase rotation.  
High Efficiency – High efficiency units reach as high as  
11.2 EER. Gas/electric units have electronic spark ignition  
and power vented combustion with steady state efficiencies  
of 80%. These efficiencies exceed all legislated minimum  
levels and provide low operating costs.  
®
Service Friendly – The Predator incorporates a number  
of enhancements which improve serviceability.  
The motor and blower slide out of the unit as a common  
assembly. This facilitates greater access to all the indoor  
airflow components, thus simplifying maintenance and  
adjustment.  
Advanced Controls - Simplicity® control boards have  
standardized a number of features previously available  
only as options or by utilizing additional controls.  
Service time is reduced through the use of hinged,  
toolless panels. Such panels provide access to frequently  
inspected components and areas, including the control  
box, compressors, filters, indoor motor & blower, and the  
heating section. The panels are screwed in place at the  
factory to prevent access by children or other  
Low Ambient - An integrated low-ambient control  
allows all units to operate in the cooling mode down to  
0F outdoor ambient without additional assistance.  
Optionally, the control board can be programmed to  
lockout the compressors when the outdoor air temper-  
ature is low or when free cooling is available.  
unauthorized persons. It is recommended that the panels  
be secured with screws once service is complete.  
Service windows have been placed in both condenser  
section walls. Rotation of the cover allows easy access to  
the condenser coils for cleaning or inspection.  
The Simplicity® control board used in this product  
will effectively operate the cooling system down to  
0°F when this product is applied in a comfort cooling  
application for people. An economizer is typically  
included in this type of application. When applying  
this product for process cooling applications (com-  
puter rooms, switchgear, etc.), please reference  
applications bulletin AE-011-07 or call the applica-  
tions department for Unitary Products @ 1-877-  
UPG-SERV for guidance. Additional accessories  
may be needed for stable operation at temperatures  
below 30° F.  
Both the unit control board and ignition control board utilize  
flash codes to aid in diagnosis of unit malfunctions. Unique  
alarm codes quickly identify the source of the unit alarm.  
All units use the same standard filter size. This  
standardization removes any confusion on which filter  
sizes are needed for replacement.  
The non-corrosive drain pan slides out of the unit to permit  
easy cleaning. The drain pan is accessed by removing the  
drain pan cover plate on the rear of the unit. Once the plate is  
removed, the drain pan slides out through the rear of the unit.  
®
All Predator units have a second model nameplate  
located inside the control access door. This is to prevent  
deterioration of the nameplate through weathering.  
Anti-Short Cycle Protection - To aid compressor life,  
an anti-short cycle delay is incorporated into the stan-  
dard controls. Compressor reliability is further ensured  
by programmable minimum run times. For testing, the  
anti-short cycle delay can be temporarily overridden  
with the push of a button.  
• Coil Technology – ZF condensers utilize Micro-Channel  
“all aluminum” condensers which provide improved heat  
transfer capabilities and reduced charge volumes.  
Environmentally Aware – For improved Indoor Air  
Quality, a combination of foil faced and elastometric  
rubber insulation is used exclusively throughout the units.  
Fan Delays - Fan on and fan off delays are fully pro-  
grammable. Furthermore, the heating and cooling fan  
delay times are independent of one another. All units  
are programmed with default values based upon their  
configuration of cooling and heat.  
®
Balanced Heating – The Predator offers “Ultimate  
st  
nd  
Heating Comfort” with a balance between 1 and 2 stage  
®
gas heating. The first stage of a gas heat Predator unit  
provides 60% of the heating capacity. Balanced heating  
allows the unit to better maintain desired temperatures.  
Safety Monitoring - The control board monitors the  
high and low-pressure switches, the freezestats, the  
gas valve, if applicable, and the temperature limit  
switch on gas and electric heat units. The unit control  
board will alarm on ignition failures, compressor lock-  
outs and repeated limit switch trips.  
Convertible Airflow Design – The side duct openings  
are covered when they leave the factory. If a side supply/  
return is desired, the installer simply removes the two side  
duct covers from the outside of the unit and installs them  
over the down shot openings. No panel cutting is required.  
Convertible airflow design allows maximum field flexibility  
and minimum inventory.  
Nuisance Trip Protection and Strikes - To prevent  
nuisance trouble calls, the control board uses a “three  
times, you’re out” philosophy. The high and low-pres-  
4
Johnson Controls Unitary Products  
 
528194-YTG-F-1210  
sure switches and the freezestats must trip three times  
within two hours before the unit control board will lock  
out the associated compressor.  
Warranty - All models include a 1-year limited warranty  
on the complete unit. Compressors and electric heater  
elements each carry a 5-year warranty. Aluminized steel  
and stainless steel tubular heat exchangers carry a 10-  
year warranty.  
On Board Diagnostics - Each alarm will energize a  
trouble light on the thermostat, if so equipped, and  
flash an alarm code on the control board LED. Each  
high and low-pressure switch alarm as well as each  
freezestat alarm has its own flash code. The control  
board saves the five most recent alarms in memory,  
and these alarms can be reviewed at any time.  
Alarms and programmed values are retained through  
the loss of power.  
Factory Installed Options  
®
YORK offers several equipment options factory installed, for  
®
the Predator line.  
Optional Factory Installed Economizers - Predator units  
offer a variety of optional factory installed economizers  
with low leak dampers. The outdoor air enthalpy sensor  
enables economizer operation if the outdoor enthalpy is  
less than the setpoint of the economizer logic module. See  
economizer options section to determine the correct  
economizer for your application.  
Reliable – From the beginning – All units undergo  
computer automated testing before they leave the factory.  
Units are tested for refrigerant charge and pressure, unit  
amperage, and 100% functionality. For the long term – All  
Downflow Economizer - (With barometric relief) -  
The economizer is provided with a single enthalpy input.  
The economizer is 2% low leakage type, and is shipped  
installed and wired. The installer needs only to  
®
Predator units are painted with a long lasting, powder  
paint that stands up over the life of the unit. The paint  
used has been proven by a 1000 hour salt spray test.  
Flexible Placement – All models and configurations  
share the same cabinet/footprint and thus the same roof  
curb. You have the flexibility to set one curb and choose  
the correct tonnage size and heating option after the  
internal loads have been determined.  
assemble and mount the outdoor air hood (Provided).  
The economizer has spring return, fully modulating  
damper actuators and is capable of introducing up to  
100% outdoor air. As the outdoor air intake dampers  
open, the return air dampers close. The changeover  
from mechanical refrigeration to economizer operation is  
regulated by the standard single enthalpy input. There is  
an optional input dual dry bulb available. To meet  
regulated air standards, the economizer control accepts  
®
To further simplify planning and installation, Predator ZF  
cabinets are designed to fit your roof. With the optional  
roof curb, the unit ductwork is designed to fit around 24”  
on-center joists or between 48” on-center joists.  
an optional CO input for demand ventilation. With  
The drain pan can be rotated to drain to either the front or  
the rear of the unit. Additionally, the drain pan can be  
fitted to drain through the roof curb. As it is sometimes  
difficult to have a level installation, the drain pan features  
a generous slope to ensure proper drainage.  
2
single enthalpy input, the economizer control monitors  
outdoor air. The dual enthalpy kit provides a second  
input used to monitor the return air. With a dual input kit  
installed, the economizer control compares the values of  
the two enthalpy or temperature inputs and positions the  
dampers to provide the maximum efficiency possible.  
Full Perimeter Base Rails – The permanently attached  
base rails provide a solid foundation for the entire unit and  
protect the unit during shipment. The rails offer forklift  
access from 3 sides, and rigging holes are available so that  
an overhead crane can be used to place the units on a roof.  
Horizontal Economizer - (Without barometric relief) -  
All features of the downflow economizer exist except you  
must order the duct mount barometric relief separately.  
You must order a 1EH0408 if you are installing a  
power exhaust. You can order a 1RD0411 Barometric  
Relief for horizontal flow economizers only.  
Easy Installation – Gas and electric utility knockouts are  
supplied in the unit underside as well as the side of the unit.  
A clearly identified location is provided to mount a field  
supplied electrical disconnect switch. Utility connections can  
be made quickly and with a minimum amount of field labor.  
BAS Ready Economizer -(With barometric relief) -  
The economizer is provided with an actuator that  
requires a 2-10V DC input from an external source (i.e.,  
field installed building automation system controller).  
Power exhaust options are available. The economizer is  
2% low leakage type with spring return and fully  
modulating dampers capable of introducing up to 100%  
outside air. Also include 2” pleated filters. BAS Ready  
actuators have an adjustable auxiliary end-switch for  
optional power exhaust control.  
All units are shipped with 2” throw-away filters installed.  
Wide Range of Indoor Airflows – All indoor fan motors  
are belt-drive type providing maximum flexibility to handle  
most airflow requirements. For high static applications,  
factory installed alternate indoor fan motors are available.  
With the optional indoor fan motor, all units can supply  
nominal airflow at a minimum of 1.5” ESP.  
A variable air volume (VAV) option using a variable  
frequency drive is available on 6-1/2 through 12-1/2 ton,  
ZF models for applications requiring a constant supply  
duct pressure. A differential pressure transducer is used  
to monitor supply duct static pressure while a VAV control  
board provides a speed reference signal to the VFD to  
control the output of the indoor blower motor.  
For units with optional VAV or Simplicity® Intelli-  
Comfort™ control, a factory-installed, dry bulb sensor  
determines if outdoor air temperature is low enough to  
provide free-cooling operation. (Field-installed humidity  
sensors for either outdoor air or outdoor & return air  
streams are available for single enthalpy and differential  
enthalpy configurations respectively).  
Johnson Controls Unitary Products  
5
528194-YTG-F-1210  
Slab Economizer for Energy Recovery Ventilators-  
If the drive will not fit in the allotted space, then it will have  
to be mounted elsewhere; either within the building on a  
perpendicular wall which is not subjected to excessive  
temperature, vibration, humidity, dust, corrosive gas,  
explosive gas, etc., or within an appropriate enclosure  
rated for outside installation to safeguard against  
moisture, dust and excessive heat. A terminal block  
located in the control box is provided for field connection  
of the VFD controls.  
(With barometric relief and Fresh Air Hood) - The  
economizer is provided with a single enthalpy input. The  
economizer is 2% low leakage type, and is shipped  
installed and wired. The economizer has spring return,  
fully modulating damper actuators and is capable of  
introducing up to 100% outdoor air. As the outdoor air  
intake dampers open, the return air dampers close. The  
changeover from mechanical refrigeration to economizer  
operation is regulated by the standard single enthalpy  
input. There is an optional input dual dry bulb available.  
To meet regulated air standards, the economizer control  
Aluminized Steel Gas Heat Exchanger - For  
applications in non-corrosive environments.  
Stainless Steel Gas Heat Exchanger - For applications  
in corrosive environments, this option provides a full  
stainless steel heat exchanger assembly.  
accepts an optional CO input for demand  
2
ventilation.With single enthalpy input, the economizer  
control monitors outdoor air. The dual enthalpy kit  
provides a second input used to monitor the return air.  
With a dual input kit installed, the economizer control  
compares the values of the two enthalpy or temperature  
inputs and positions the dampers to provide the  
maximum efficiency possible.  
Stainless Steel Drain Pan - An optional rust-proof  
stainless steel drain pan is available to provide years of  
trouble-free operation in corrosive environments.  
Electric Heaters - The electric heaters range from 9kW to  
54kW and are available in all the voltage options of the  
base units. All heaters are dual staged. All heaters are  
intended for single point power supply.  
Power Exhaust (Downflow only) - This accessory  
installs in the unit with a down flow economizer.  
Disconnect Switch - For gas heat units and cooling units  
with electric heat, a HACR breaker sized to the unit is  
provided. For cooling only units, a switch sized to the  
largest electric heat available for the particular unit is  
provided. Factory installed option only.  
Motorized Outdoor Air Damper - The motorized outdoor  
air damper includes a slide-in/plug-in damper assembly  
with an outdoor air hood and filters. The outdoor air  
dampers open to the preset position when the indoor fan  
motor is energized. The damper has a range of 0% to  
100% outdoor air entry. Factory installed option or field  
installed accessory.  
Convenience Outlet - (Non-Powered/Powered) - This  
option locates a 120V single-phase GFCI outlet with cover,  
on the corner of the unit housing adjacent to the  
compressors. The “Non-powered” option requires the  
installer to provide the 120V single-phase power source and  
wiring. The “Powered” option is powered by a stepdown  
transformer in the unit. Factory installed option only.  
Alternate Indoor Blower Motor - For applications with  
high static restrictions, units are offered with optional  
indoor motors that provide higher static output and/or  
higher airflow, depending upon the installer’s needs.  
Variable Air Volume (VAV); 6-1/2 through 12-1/2 ton -  
A factory-installed variable frequency drive (VFD),  
mounted in the Blower Access compartment, is used to  
control the speed of the indoor blower motor in order to  
maintain a constant static pressure in the supply duct. A  
pressure transducer and VAV control board are mounted  
inside the control box. The drive comes completely wired  
and preprogrammed from the factory.  
Smoke Detectors - The smoke detectors stop operation  
of the unit by interrupting power to the control board if  
smoke is detected within the air compartment. Available  
for both the supply and/or return air configurations.  
Filters – 2” Pleated MERV 7 or 4” Pleated MERV 13 are  
available to meet LEED requirements. A 2” Throwaway is  
shipped as standard.  
An optional, factory-installed manual bypass switch  
available with factory-installed VFD can be found in the  
Blower Motor Access compartment. The switch can be  
used to either route power to the VFD for modulating  
control of the blower motor, to bypass the drive and  
operate the motor at full speed, or to power the drive (and  
not the motor) for diagnostic purposes.  
Factory-installed smoke detectors may be subjected to  
extreme temperatures during "off" times due to outside air  
infiltration. These smoke detectors have an operational  
range of -4 °F to 158°F. Smoke detectors installed in areas  
that could be outside this range will have to be relocated to  
prevent false alarms.  
Due to space limitations, VAV is not available with any of  
the factory-installed BAS options, but is available with  
‘BAS-ready’ models. Terminal blocks are provided in the  
control box for field wiring of the customer-installed BAS  
Phase Monitors - Designed to prevent unit damage. The  
phase monitor will shut the unit down in an out-of phase  
condition. (Standard on units with Scroll Compressors.)  
A ‘VFD-ready’ option provides the provisions for a  
customer-installed drive. The unit comes with a mounting  
bracket installed in the Blower Access compartment which  
may accommodate other vendor’s drives depending on  
their size. In order to utilize the unit’s mounting bracket,  
the maximum recommended drive dimensions are limited  
to approximately 9” H x 5” W x 7.5” D.  
Coil Guard - Customers can purchase a coil guard kit to  
protect the condenser coil from damage. Additionally, this  
kit stops animals and foreign objects from entering the  
space between the inner condenser coil and the main  
cabinet. This is not a hail guard kit.  
6
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Dirty Filter Switch - This kit includes a differential  
pressure switch that energizes the fault light on the unit  
thermostat, indicating that there is an abnormally high  
pressure drop across the filters. Factory installed option or  
field installed accessory.  
factory installed. Includes supply air sensor, return air  
sensor, dirty filter indicator switch, and air proving switch.  
CPC BAS Control - The Computer Process Controls  
Model 810-3060 ARTC Advanced Rooftop building  
automation system controller is factory installed. Includes  
supply air sensor, return air sensor, dirty filter indicator  
switch and air proving switch.  
Technicoat Condenser Coils - The condenser coils are  
coated with a phenolic coating for protection against  
corrosion due to harsh environments.  
Honeywell BAS Control - The Honeywell W7750C  
building automation system controller is factory installed.  
Includes air supply sensor, return air sensor, dirty filter  
indicator switch, and air proving switch.  
Technicoat Evaporator Coil - The evaporator coils are  
coated with a phenolic coating for protection against  
corrosion due to harsh environments.  
Hot Gas Bypass - Allows operation during low load  
conditions while avoiding coil frosting and damage to  
compressor. When suction pressure falls below valve  
setpoint, the valve modulates hot gas to the inlet of the  
evaporator.  
York Commercial Comfort System (YCCS) - Provides  
rooftop system integration for YCCS single zone and  
change-over bypass systems (Not offered on ZR units.).  
Field Installed Accessories  
®
YORK offers several equipment accessories for field  
HGBP is standard on all units with VAV, and optional with  
constant-volume units.  
®
installation, for the Predator line.  
Downflow Economizer - (With barometric relief) - The  
economizer is provided with a single enthalpy input. The  
economizer is 2% low leakage type. The economizer has  
spring return, fully modulating damper actuators and is  
capable of introducing up to 100% outdoor air. As the  
outdoor air intake dampers open, the return air dampers  
close. The changeover from mechanical refrigeration to  
economizer operation is regulated by the standard single  
enthalpy input. There is an optional input dual dry bulb  
available. To meet regulated air standards, the economizer  
Control Options  
®
BAS - Building Automation System Controls Simplicity  
INTELLI-Comfort™ Control - The York Simplicity  
®
®
INTELLI-Comfort™ control is factory installed. It includes a  
supply air sensor, a return air sensor, and an outside air  
sensor. There are provisions for a field installed dirty filter  
indicator switch, an air-proving switch, an Outside Air  
Humidity sensor, a Return Air Humidity sensor, an Inside  
IAQ sensor, and an Outside Air IAQ sensor. Construction  
mode operation, 365-day real time clock with 7 day  
programming plus holiday scheduling is built-in. Two  
different modes of demand ventilation are achieved through  
control accepts an optional CO input for demand  
2
ventilation. With single enthalpy input, the economizer  
control monitors outdoor air. The dual enthalpy kit provides a  
second input used to monitor the return air. With a dual input  
kit installed, the economizer control compares the values of  
the two enthalpy or temperature inputs and positions the  
dampers to provide the maximum efficiency possible.  
the INTELLI-Comfort™ using CO sensors. It uses an  
2
inside CO sensor to perform Demand Ventilation. It can  
2
also use an Outside CO sensor to perform Differential  
Demand Ventilation. It uses a Patented Comfort Ventilation  
algorithm to provide comfortable ventilation air  
2
Horizontal Economizer - (Without barometric relief) -  
All features of the downflow economizer exist except you  
must order the duct mount barometric relief separately.  
You must order a 1EH0408 if you are installing a  
power exhaust. You can order a 1RD0411 Barometric  
Relief for horizontal flow economizer.  
temperature. The patented economizer-loading algorithm  
will protect the equipment when harsh operating conditions  
exist. Humidity in the occupied space or return duct can be  
monitored and controlled via humidity sensors and the on-  
board connection for hot gas re-heat system. It uses the  
INTELLI-Start™ algorithm to maximize energy savings by  
recovering the building from the Unoccupied Setpoints to  
the Occupied Setpoints just in time for the Occupied Time  
Slab Economizer for Energy Recovery Ventilator-  
(Without barometric relief or Fresh Air Hood) - The  
economizer is provided with a single enthalpy input. The  
economizer is 2% low leakage type. The economizer has  
spring return, fully modulating damper actuators and is  
capable of introducing up to 100% outdoor air. As the  
outdoor air intake dampers open, the return air dampers  
close. The changeover from mechanical refrigeration to  
economizer operation is regulated by the standard single  
enthalpy input. There is an optional input dual dry bulb  
available. To meet regulated air standards, the economizer  
®
Period to begin. The Simplicity INTELLI-Comfort™  
balances space temperature, ventilation air temperature,  
CO and humidity for ultimate comfort.  
2
®
Simplicity INTELLI-Comfort™ with Simplicity®LINC  
®
Control - The York® Simplicity INTELLI-Comfort™ with  
Simplicity®LINC control is factory installed. It includes all  
the features of the INTELLI-Comfort™ control with an  
additional control to translate communications from  
MODBUS to the BACnet MSTP protocol.  
control accepts an optional CO input for demand  
2
Novar® BAS Control - The Novar® building automation  
system controller is factory installed. Incudes supply air  
sensor, return air sensor, dirty filter indicator switch, and  
air proving switch.  
ventilation.With single enthalpy input, the economizer control  
monitors outdoor air. The dual enthalpy kit provides a  
second input used to monitor the return air. With a dual input  
kit installed, the economizer control compares the values of  
the two enthalpy or temperature inputs and positions the  
dampers to provide the maximum efficiency possible.  
Johnson Controls BAS Control - The Johnson Control  
YK-UNT-1126 building automation system controller is  
Johnson Controls Unitary Products  
7
528194-YTG-F-1210  
You can order 1EH0409 Barometric Relief/FA Hood for  
field installations without an ERV.  
valve and controls will continue to function properly at  
extremely low temperatures.  
Dual Enthalpy Control, Accessory - This kit contains  
the required components to convert a single enthalpy  
economizer to dual enthalpy.  
Gas Heat High Altitude Kit - This kit converts a gas heat  
unit to operate at high altitudes, 2,000 to 6,000 feet.  
Conversion kits are available for natural gas and propane.  
Barometric Relief Damper - Zero to 100% capacity  
barometric relief dampers for use with horizontal flow, or  
field installed slab economizers.  
Gas Heat Propane Conversion Kit - This kit converts a  
gas-fired heater from natural gas to propane. It contains the  
main burner orifices and gas valve replacement springs.  
Power Exhaust - This accessory installs in the unit with a  
down flow economizer. Power exhaust plugs into the  
connector in the unit bulkhead. You must purchase  
1EH0408 barometric relief when applying to a  
horizontal flow application.  
Gas Piping Kit - Contains pipe nipples, fittings and gas cock  
required for gas supply connection with external shut off.  
Electric Heaters - The electric heaters range from 9 kW  
to 54kW and are available in all the voltage options of the  
base units. The 54kW/208-240 volt, Field-installed heater  
kit is not available with VAV units due to a lack of space to  
accommodate the heater’s fuse block accessory.  
Manual Outdoor Air Damper - Like the motorized outdoor  
air damper, each manual outdoor air damper includes a  
slide-in damper assembly with an outdoor air hood and  
filters. Customers have a choice of dampers with ranges of  
0% to 100% or 0% to 35% outdoor air entry.  
All heaters are dual staged. Cooling units include an  
adapter panel for easy installation of the electric heaters.  
Necessary hardware and connectors are included with the  
heaters. All heaters are intended for single point power  
supply.  
Motorized Outdoor Air Damper - The motorized outdoor  
air damper includes a slide-in/plug-in damper assembly with  
an outdoor air hood and filters. The outdoor air dampers  
open to the preset position when the indoor fan motor is  
energized. The damper has a range of 0% to 100% outdoor  
air entry. Factory installed option or field installed accessory.  
• Low Limit / Compressor Lockout Kit  
Compressor Lockout (CLO): To prevent mechanical  
(compressorized) operation of the unit during cold  
outdoor conditions where there is a risk of returning  
liquid refrigerant back to the compressors.  
Smoke Detectors - The smoke detectors stop operation  
of the unit by interrupting power to the control board if  
smoke is detected within the air compartment.  
Low Limit Control (LLC): To prevent the supply air  
from dropping below a specified setpoint by utilizing the  
units first stage heating means when there is a demand  
for cooling during cold outside conditions.  
CO Sensor - Senses CO levels and automatically  
2
2
overrides the economizer when levels rise above the  
preset limits.  
Metal Frame Filter Kit - Metal frame with polyester filter  
Dirty Filter Switch - This kit includes a differential  
pressure switch that energizes the fault light on the unit  
thermostat, indicating that there is an abnormally high  
pressure drop across the filters.  
medium.  
Permanent Filters - Permanent filters are available.  
Roof Curbs - The roof curbs have insulated decks and are  
shipped disassembled The roof curbs are available in 8” and  
14” heights. For applications with security concerns, burglar  
bars are available for the duct openings of the roof curbs.  
Coil Guard - Field installed decorative wire coil guard.  
Hail Guard - This kit includes a sloped hood which installs  
over the outside condenser coil and prevents damage to  
the coil fins from hail strikes. Field installed accessory only.  
Roof Curb Transition - Single Piece Adapter (10” High) -  
Roof curbs for transitioning from Sunline™ units to  
Predator units. Fits 7.5 to 12.5 Sunline™ roof curbs only.  
Flue Exhaust Extension Kit - In locations with wind or  
weather conditions which may interfere with proper  
exhausting of furnace combustion products, this kit can be  
installed to prevent the flue exhaust from entering nearby  
fresh air intakes.  
®
Burglar Bars - Mount in the supply and return openings  
to prevent entry into the duct work.  
Thermostat - The units are designed to operate with 24-  
volt electronic and electro-mechanical thermostats. All  
units (with or without an economizer) operate with two-  
stage heat/two-stage cool or two-stage cooling only  
thermostats, depending upon unit configuration.  
-60°F Gas Heat Kit - For installations which require gas  
heat units to perform in low ambient temperatures, a gas  
section heating kit is available. This kit provides electric  
heat in the gas heat controls section to ensure the gas  
8
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Accessories  
Field Installed Acessories - Non-Electrical  
MODEL  
VOLTAGE DESCRIPTION  
WHERE USED  
1BD0408  
All  
All  
All  
All  
All  
Burglar Bars, Downflow  
All Cabinets  
1CG0419  
1CG0420  
1CG0427  
1CG0428  
Coil Guard  
Coil Guard  
Coil Guard  
Coil Guard  
(Electric / Electric Models), 50” Tall Standard Cabinets  
(Gas / Electric Models), 50" Tall Standard Cabinets  
(Electric / Electric Models), 42” Tall Cabinets  
(Gas / Electric Models), 42" Tall Cabinets  
All Tall (50") Standard Cabinets, (Excludes 12.5T "V"  
cabinets)  
All Short (42") Standard Cabinets  
All Cabinets  
All Tall 50" Cabinets  
All Tall 42" Cabinets  
All Tall 50" Cabinets  
All Tall 42" Cabinets  
All Cabinets  
1HG0411  
1HG0415  
1FE0411  
1FF0414  
1FF0415  
1FL0402  
1FL0423  
1GP0405  
1HA0442  
1HA0443  
1NP0442  
1RC0470  
1RC0471  
All  
All  
All  
All  
All  
All  
All  
All  
All  
All  
All  
All  
All  
Hail Guard Kit  
Hail Guard Kit  
Flue Exhaust Extension Kit  
2" only Metal Filter Frame Kit  
2" only Metal Filter Frame Kit  
Permanent 2" only Filter Kit Includes (4) Four Filters)  
Permanent 2" only Filter Kit (Includes (4) four Filters)  
Gas Piping Kit  
High Altitude Kit for Natural Gas  
High Altitude Kit for Propane  
Propane Conversion Kit  
All 6 - 12T Cabinets  
All 6 - 12T Cabinets  
All 6 - 12T Cabinets  
All Cabinets  
Roof Curb, 8" Height  
Roof Curb, 14" Height  
All Cabinets  
Roof Curb, Transition (7.5 T thru 12.5T Sunline to  
Predator 3- 12T)  
Wooden Crate for extra protection during shipping and  
handling  
1RC0472  
1WC0412  
All  
All  
All Cabinets  
Standard Cabinets Only (not applicable to units 119" in  
length)  
Field Installed Acessories - Electric Heat  
MODEL  
VOLTAGE DESCRIPTION  
WHERE USED  
2TP04520925  
2TP04520946  
2TP04520958  
2TP04531825  
2TP04531846  
2TP04521858  
2TP04532425  
2TP04532446  
2TP04522458  
2TP04533625  
2TP04533646  
2TP04523658  
2TP04525425  
2TP04525446  
2TP04525458  
2TP04540925  
2TP04540946  
2TP04540958  
2TP04541825  
2TP04541846  
2TP04541858  
2TP04542425  
2TP04542446  
2TP04542458  
2TP04543625  
2TP04543646  
2TP04543658  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
230  
460  
575  
9kW Electric Heat  
18kW Electric Heat  
24kW Electric Heat  
36kW Electric Heat  
54kW Electric Heat  
9kW Electric Heat  
18kW Electric Heat  
24kW Electric Heat  
36kW Electric Heat  
All 50" Cabinet 6.5 and 8.5 Ton Models  
All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models  
All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models  
All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models  
All 50" 10 and 12.5 Ton Models  
All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models  
All 42" 6.5, 7.5 and 8.5 Ton Models  
All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models  
All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models  
Johnson Controls Unitary Products  
9
528194-YTG-F-1210  
Accessories (Continued)  
Field Installed Acessories - Fresh Air  
MODEL  
VOLTAGE DESCRIPTION  
WHERE USED  
All Cabinets  
All Cabinets  
Barometric Relief Kit for Power Exhaust, Downflow  
All  
All  
1EH0407  
Application (Includes Hood)  
Barometric Relief Kit for Power Exhaust, Horizontal  
Application  
1EH0408  
Barometric Relief/Hood Kit - Required for field installed  
slab economizer without ERV  
Manual Outside Air Damper 0-35%, Downflow  
Manual Outside Air Damper 0-100%, Downflow  
Barometric Relief Kit for Horizontal Applications  
Dual Enthalpy Control  
1EH0409  
1FA0413  
1FA0414  
1RD0411  
2EC04700924  
All  
All  
All  
All  
All  
All Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
Downflow Economizer, Slab type for ERV, (no  
Barometric Relief or FA hood)  
2EE04705724  
All  
All 50" Cabinets  
Downflow Economizer, Slab type for ERV, (no  
Barometric Relief or FA hood)  
Downflow Economizer with Barometric Relief  
Horizontal Economizer without Barometric Relief  
Motorized Damper, Downflow without Barometric Relief All Cabinets  
Motorized Damper, Horizontal  
Power Exhaust 230V Downflow or Horizontal  
Power Exhaust 460V Downflow or Horizontal  
Power Exhaust 575V Downflow or Horizontal  
2EE04705824  
2EE04705924  
2EE04706024  
2MD04703224  
2MD04703724  
2PE04703225*  
2PE04703246*  
2PE04703258*  
All  
All  
All  
All  
All  
230  
460  
575  
All 42" Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
All Cabinets  
* Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required.  
Field Installed Acessories - Controls  
MODEL  
2AP0401  
2AQ04700324  
2AQ04700424  
2DF0402  
VOLTAGE DESCRIPTION  
WHERE USED  
All Units  
All Units  
All Units  
All Units  
All Units  
All  
All  
All  
All  
All  
Air Proving Switch  
CO2 Space Accessory  
CO2 Unit Accessory  
Dirty Air Switch  
2DH04700024  
Humidistat  
All Gen 4 or older units with 2" Filter only capable  
Cabinets  
All Gen 5 units with 2" & 4" Filters  
All Gen 5 units with 2" & 4" Filters  
All Gen 5 units with 2" & 4" Filters  
2SD04700624  
2SD04700824  
2SD04700924  
2SD04701024  
All  
All  
All  
All  
Smoke Detector for Supply or Return  
Smoke Detector for Supply  
Smoke Detector for Return  
Smoke Detector for Supply and Return  
Field Installed Acessories - Electrical  
MODEL  
VOLTAGE DESCRIPTION  
WHERE USED  
2BC04700106  
2BC04700151  
2BC04700154  
2LA04704632  
230  
460  
575  
All  
Gas heat kit, -60ºF  
Gas heat kit, -60ºF  
Gas heat kit, -60ºF  
Low Ambient Kit  
All Units  
All Units  
All Units  
All 3 - 10T units (excludes 12.5T "V" cabinets)  
®
sizes. Predator units are available in the following  
Guide Specifications  
configurations: cooling only, cooling with electric heat, cooling  
with gas heat, heat pump, and heat pump with electric heat.  
Electric heaters are available as factory-installed options or  
field-installed accessories.  
GENERAL  
Units shall be manufactured by York International Unitary  
Products in an ISO 9001 certified facility. YORK® Predator  
®
units are convertible single packages with a common footprint  
cabinet and common roof curb for all 6-1/2 through 12-1/2 ton  
models. All units have two compressors with independent R-  
410A refrigeration circuits to provide 2 stages of cooling. The  
units were designed for light commercial applications and can  
DESCRIPTION  
Units shall be factory assembled, single package, (Elec/Elec, Gas/  
Elec), designed for outdoor installation. They shall have built in  
field convertible duct connections for down discharge supply/return  
or horizontal discharge supply/return and be available with factory  
installed options or field installed accessories. The units shall be  
factory wired, piped and charged with R-410A refrigerant and  
factory tested prior to shipment. All unit wiring shall be both  
numbered and color coded. The cooling performance shall be  
rated in accordance with DOE and ARI test procedures. Units shall  
be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236-  
M90 standards.  
®
be easily installed on a roof curb, slab, or frame. All Predator  
units are self-contained and assembled on rigid full perimeter  
base rails allowing for 3-way forklift access and overhead  
rigging. Every unit is completely charged with R-410A, wired,  
piped, and tested at the factory to provide a quick and easy  
field installation. All units are convertible between side and  
down airflow. Independent economizer designs are used on  
side and down discharge applications, as well as all tonnage  
10  
Johnson Controls Unitary Products  
 
528194-YTG-F-1210  
UNIT CABINET  
a. Evaporator coils shall have aluminum plate fins  
mechanically bonded to seamless internally enhanced  
copper tubes with all joints brazed. Special Phenolic  
coating shall be available as a factory option.  
Unit cabinet shall be constructed of galvanized steel with  
exterior surfaces coated with a non-chalking, powder paint  
finish, certified at 1000 hour salt spray test per ASTM-B117  
standards. Indoor blower sections shall be insulated with up to  
1” thick insulation coated on the airside. Either aluminum foil  
faced or elastometric rubber insulation shall be used in the  
unit’s compartments and be fastened to prevent insulation from  
entering the air stream. Cabinet doors shall be hinged with  
toolless access for easy servicing and maintenance. Full  
perimeter base rails shall be provided to assure reliable transit  
of equipment, overhead rigging, fork truck access and proper  
sealing on roof curb applications. Disposable 2” filters shall be  
furnished as standard and be accessible through hinged access  
door. Fan performance measuring ports shall be provided on  
the outside of the cabinet to allow accurate air measurements  
of evaporator fan performance without removing panels or  
creating bypass of the coils. Condensate pan shall be slide out  
design, constructed of a non corrosive material, internally  
sloped and conforming to ASHRAE 62-B9 standards.  
Condensate connection shall be a minimum of ¾” I.D. female  
and be rigid mount connection.  
b. Evaporator coils shall be of the direct expansion, draw-  
thru design.  
c. Condenser coils shall have Mirco-Channel aluminum  
tube, aluminum fins.  
d. Condenser coils shall be of the direct expansion, draw-  
thru design.  
Refrigerant Circuit and Refrigerant Safety Components shall  
include:  
a. Independent fixed-orifice or thermally operated  
expansion devices.  
b. Solid core filter drier/strainer to eliminate any moisture or  
foreign matter.  
c. Accessible service gage connections on both suction  
and discharge lines to charge, evacuate, and measure  
refrigerant pressure during any necessary servicing or  
troubleshooting, without losing charge.  
INDOOR (EVAPORATOR) FAN ASSEMBLY  
d. The unit shall have two independent refrigerant circuits,  
equally split in 50% capacity increments.  
Fan shall be a belt drive assembly and include an adjustable  
pitch motor pulley. Job site selected brake horsepower shall not  
exceed the motors nameplate horsepower rating plus the ser-  
vice factor. Units shall be designed to operate within the service  
factor. Fan wheel shall be double inlet type with forward curve  
blades, dynamically balanced to operate smoothly throughout  
the entire range of operation. Airflow design shall be constant  
volume. Bearings shall be sealed and permanently lubricated  
for longer life and no maintenance. Entire blower assembly and  
motor shall be slide out design.  
Unit Controls:  
a. Unit shall be complete with self-contained low-voltage  
control circuit protected by a resettable circuit breaker on  
the 24-volt transformer side.  
b. Unit shall incorporate a lockout circuit which provides  
reset capability at the space thermostat or base unit  
should any of the following standard safety devices trip  
and shut off compressor:  
c. Loss-of-charge/Low-pressure switch.  
• High-pressure switch.  
OUTDOOR (CONDENSER) FAN ASSEMBLY  
The outdoor fans shall be of the direct drive type, discharge air  
vertically, have aluminum blades riveted to corrosion resistant  
steel spider brackets and shall be dynamically balanced for  
smooth operation. The outdoor fan motors shall have permanently  
lubricated bearings internally protected against overload  
conditions and staged independently. A cleaning window shall be  
provided on two sides of the units for coil cleaning.  
• Freeze-protection thermostat, evaporator coil. If any of  
the above safety devices trip, an LED (light-emitting  
diode) indicator shall flash a diagnostic code that  
indicates which safety switch has tripped.  
d. Unit shall incorporate “AUTO RESET” compressor over  
temperature, over current protection.  
e. Unit shall operate with conventional thermostat designs  
and have a low voltage terminal strip for easy hook-up.  
REFRIGERANT COMPONENTS  
Compressors:  
f. Unit control board shall have on-board diagnostics and  
fault code display.  
a. Shall be fully hermetic type, direct drive, internally  
protected with internal high-pressure relief and over  
temperature protection. The hermetic motor shall be  
suction gas cooled and have a voltage range of + or –  
10% of the unit nameplate voltage.  
g. Standard controls shall include anti-short cycle and low  
voltage protection, and permit cooling operation down to  
0 ºF.  
h. Control board shall monitor each refrigerant safety switch  
independently.  
b. Shall have internal spring isolation and sound muffling to  
minimize vibration and noise, and be externally isolated  
on a dedicated, independent mounting.  
i. Control board shall retain last 5 fault codes in non-  
volatile memory, which will not be lost in the event of a  
power loss.  
Coils:  
Johnson Controls Unitary Products  
11  
528194-YTG-F-1210  
GAS HEATING SECTION (IF EQUIPPED)  
intake dampers shall not exceed 2% when dampers are  
fully closed and operating against a pressure differential  
of 0.5 IWG. A unit-mounted potentiometer shall be  
provided to adjust the outdoor and return air damper  
assembly to take in outdoor air to meet the minimum  
ventilation requirement of the conditioned space during  
normal operation. During economizer operation, a mixed-  
air temperature control shall modulate the outdoor and  
return air damper assembly to prevent the supply air  
temperature from dropping below 55 ºF. Changeover from  
compressor to economizer operation shall be provided by  
an integral electronic enthalpy control that feeds input into  
the basic module. The outdoor intake opening shall be  
covered with a rain hood that matches the exterior of the  
unit. Water eliminator/filters shall be provided.  
Heat exchanger and exhaust system shall be constructed of  
aluminized steel and shall be designed with induced draft com-  
bustion with post purge logic, energy saving direct spark igni-  
tion, and redundant main gas valve. The heat exchanger shall  
be of the tubular type, constructed of T1-40 aluminized steel for  
corrosion resistance and allowing minimum mixed air entering  
temperature of 40 ºF. Burners shall be of the in-shot type, con-  
structed of aluminum-coated steel. All gas piping shall enter the  
unit cabinet at a single location, through either the side or bot-  
tom, without any field modifications. An integrated control board  
shall provide timed control of evaporator fan functioning and  
burner ignition. Heating section shall be provided with the fol-  
lowing minimum protection:  
Simultaneous economizer/compressor operation is also  
possible. Dampers shall fully close on power loss.  
Available with barometric relief or power exhaust.  
a. Primary and auxiliary high-temperature limit switches.  
b. Induced draft pressure sensor.  
c. Flame roll out switch (manual reset).  
d. Flame proving controls.  
MOTORIZED OUTDOOR AIR DAMPERS – Outdoor and  
return air dampers that are interlocked and positioned by  
a 2-position, spring-return damper actuator. The  
e. All two stage units shall have two independent stages of  
maximum leakage rate for the outdoor air intake dampers  
shall not exceed 2% when dampers are fully closed and  
operating against a pressure differential of 0.5 IWG. A  
unit-mounted potentiometer shall be provided to adjust  
the outdoor and return air damper assembly to take in the  
design CFM of outdoor air to meet the ventilation  
requirements of the conditioned space during normal  
operation. Whenever the indoor fan motor is energized,  
the dampers open up to one of two pre-selected positions  
– regardless of the outdoor air enthalpy. Dampers return  
to the fully closed position when the indoor fan motor is  
de-energized. Dampers shall fully close on power loss.  
st  
nd  
capacity (60% 1 stage, 100% 2 stage).  
ELECTRIC HEATING SECTION (IF EQUIPPED)  
An electric heating section, with nickel chromium elements,  
shall be provided in a range of 9 thru 54 KW, offering two states  
of capacity all sizes. The heating section shall have a primary  
limit control(s) (automatic reset) to prevent the heating element  
system from operating at an excessive temperature. The Heat-  
ing Section assembly shall slide out of the unit for easy mainte-  
nance and service. Units with Electric Heating Sections shall be  
wired for a single point power supply with branch circuit fusing  
(where required).  
ADDITIONAL FACTORY INSTALLED OPTIONS  
UNIT OPERATING CHARACTERISTICS  
ALTERNATE INDOOR BLOWER MOTOR – For  
applications with high restrictions, units are available with  
optional indoor blower motors that provide higher static  
output and/or higher airflow.  
Unit shall be capable of starting and running at 125 ºF outdoor  
temperature, exceeding maximum load criteria of ARI Standard  
340/360. The compressor, with standard controls, shall be  
capable of operation down to 0 ºF outdoor temperature. Unit  
shall be provided with fan time delay to prevent cold air delivery  
before heat exchanger warms up. (Gas heat only)  
Variable Air Volume (VAV) – The VAV option using a  
varible frequency drive (VFD) shall be available on 6-1/2  
through 12-1/2 ton, models for applications requiring a  
constant supply-duct static pressure. Unts equipped for  
VAV shall be controlled by a duct pressure transducer  
with a 0 - 5” WC pressure range. The pressure transducer  
shall provide a 0 - 5 VDC output signal to a VAV control  
board which, in turn shall provide a 2 - 10 VDC speed  
reference signal to the VFD. The VAV control board shall  
operate using factory-installed Supply Air, Return Air and  
Outside Air Temperature Sensors with a nominal  
ELECTRICAL REQUIREMENTS - All unit power wiring shall  
enter unit cabinet at a single factory provided location and be  
capable of side or bottom entry to minimize roof penetrations  
and avoid unit field modifications. Separate side and bottom  
openings shall be provided for the control wiring.  
STANDARD LIMITED WARRANTIES - Compressor – 5 Years,  
Heat Exchanger – 10 Years, Elect. Heat Elem. – 5 Years,  
Parts – 1 Year  
resistance of 10,000 Ohms. Units equipped with VFD’s  
shall have factory-installed manual bypass as an option.  
FACTORY INSTALLED OPTIONAL OUTDOOR AIR (Shall be  
made available by either/or):  
CONVENIENCE OUTLET (POWERED/NON-POWERED)–  
Unit can be provided with an optional 120VAC GFCI outlet  
with cover on the corner of the unit housing the compressors.  
ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER  
– Outdoor and return air dampers that are interlocked and  
positioned by a fully-modulating, spring-return damper  
actuator. The maximum leakage rate for the outdoor air  
ELECTRIC HEAT - Electric Heaters range from 9 kW to  
54 kW and are available in all the voltage options of the  
base unit.  
12  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
PHASE MONITOR - Designed to prevent damage in out-  
OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE  
of-phase condition.  
ROOF CURB - 14” and 8” high, full perimeter knockdown  
curb, with hinged design for quick assembly.  
COIL GUARD - Designed to prevent condenser coil  
damage.  
BAROMETRIC RELIEF DAMPER – (Unit mounted –  
Downflow, Duct Mounted – Horizontal) – Contains a rain  
hood, air inlet screen, exhaust damper and mounting  
hardware. Used to relieve internal air pressure through  
the unit during economizer operation.  
BAS CONTROLS - Include supply air sensor, return air  
sensor, dirty filter indicator and air proving switch.  
DIRTY FILTER SWITCH – This kit includes a differential  
pressure switch that energizes the fault light on the unit  
thermostat, indicating that there is an abnormally high-  
pressure drop across the filters.  
PROPANE CONVERSION KIT – Contains new orifices  
and gas valve springs to convert from natural to L.P. gas.  
BREAKER – An HACR breaker can be factory installed  
on gas heat units or cooling units with electric heat.  
60ºF GAS HEAT KIT – Provides an electric heat kit for the  
gas compartment for use in extreme low ambient  
conditions.  
DISCONNECT SWITCH - A disconnect can be factory  
installed on a cooling only units sized for the largest  
electric heat available.  
ECONOMIZER (Downflow and Horizontal flow)  
POWER EXHAUST – (Unit mount – Downflow, Duct  
mount – Horizontal flow)  
STAINLESS STEEL HEAT EXCHANGER – For  
applications in a corrosive environment, this option  
provides a full stainless steel heat exchanger assembly.  
DUAL ENTHALPY KIT - Provides a second input to  
economizer to monitor return air.  
SMOKE DETECTOR – A smoke detector can be factory  
mounted and wired in the supply and/or return air  
compartments.  
Johnson Controls Unitary Products  
13  
528194-YTG-F-1210  
Physical Data  
ZF078-150 Physical Data  
Component  
Models  
ZF102  
8.5  
ZF078  
6.5  
ZF090  
7.5  
ZF120  
10  
ZF150  
12.5  
Nominal Tonnage  
ARI COOLING PERFORMANCE  
Gross Capacity @ ARI A point (Mbh)  
ARI net capacity (Mbh)  
EER  
81000  
78000  
11.2  
90000  
88000  
11.2  
104000  
101000  
11.2  
126000  
120000  
11.2  
156000  
150000  
11.2  
IEER  
13  
12.1  
12.5  
12.5  
12.7  
IPLV  
12.9  
12.1  
12.5  
12.6  
13.06  
4100  
Nominal CFM  
2600  
6.95  
2500  
7.87  
3000  
4000  
System power (KW)  
Refrigerant type  
Refrigerant charge (lb-oz)  
System 1  
8.60  
10.70  
R-410A  
13.40  
R-410A  
R-410A  
R-410A  
R-410A  
4-12  
4-10  
4-12  
4-10  
4-14  
5-0  
6-8  
6-8  
7-8  
7-8  
System 2  
ARI HEATING PERFORMANCE  
Heating model  
10  
15  
180  
144  
-
10  
15  
180  
144  
-
10  
15  
180  
144  
-
15  
20  
240  
192  
-
15  
20  
240  
192  
-
Heat input (K Btu)  
Heat output (K Btu)  
AFUE %  
120  
96  
120  
96  
120  
96  
180  
144  
-
180  
144  
-
-
-
-
Steady state efficiency (%)  
No. burners  
80  
80  
80  
80  
80  
80  
80  
80  
80  
80  
4
6
4
6
4
6
6
8
6
8
No. stages  
21  
21  
21  
21  
21  
21  
21  
21  
21  
21  
Temperature Rise Range (ºF)  
Gas Limit Setting (ºF)  
Gas piping connection (in.)  
DIMENSIONS (inches)  
Length  
20-50  
165  
3/4  
35-65  
165  
3/4  
15-45  
165  
3/4  
30-60  
165  
3/4  
10-40  
215  
3/4  
25-55  
195  
3/4  
20-50  
195  
3/4  
35-65  
160  
3/4  
10-40  
195  
3/4  
25-55  
160  
3/4  
89  
59  
89  
59  
89  
59  
89  
59  
119-1/2  
Width  
59  
Height  
42  
42  
50-3/4  
1020  
50-3/4  
1060  
50-3/4  
1253  
OPERATING WT. (lbs.)  
COMPRESSORS  
Type  
860  
880  
Recip  
2
Recip  
2
Recip  
2
Recip  
2
Scroll  
2
Quantity  
Unit Capacity Steps (%)  
CONDENSER COIL DATA  
Face area (Sq. Ft.)  
Rows  
50 / 100  
50 / 100  
50 / 100  
50 / 100  
50 / 100  
18.5  
1
18.5  
1
18.5  
1
29.0  
1
29.0  
1
Fins per inch  
23  
23  
23  
23  
23  
Tube diameter (in.)/mm  
.71/18  
.71/18  
.71/18  
.71/18  
1/25  
2-pass  
2-pass  
2-pass  
2-pass  
2-pass  
Circuitry Type  
Microchannel  
Microchannel  
Microchannel  
Microchannel  
Microchannel  
EVAPORATOR COIL DATA  
Face area (Sq. Ft.)  
Rows  
10.6  
3
10.6  
3
13.2  
3
13.2  
4
13.2  
3
Fins per inch  
15  
15  
15  
15  
15  
Tube diameter  
Circuitry Type  
0.375  
Intertwined  
TXV  
0.375  
Intertwined  
TXV  
0.375  
Intertwined  
TXV  
0.375  
Intertwined  
TXV  
0.375  
Intertwined  
TXV  
Refrigerant control  
14  
Johnson Controls Unitary Products  
 
528194-YTG-F-1210  
ZF078-150 Physical Data (Continued)  
Component  
Models  
ZF102  
8.5  
ZF078  
6.5  
ZF090  
7.5  
ZF120  
10  
ZF150  
12.5  
Nominal Tonnage  
CONDENSER FAN DATA  
Quantity of Fans  
Fan diameter (Inch)  
Type  
2
24  
2
24  
2
24  
2
24  
4
24  
Prop  
Direct  
2
Prop  
Direct  
2
Prop  
Direct  
2
Prop  
Direct  
2
Prop  
Direct  
4
Drive type  
Quantity of motors  
Motor HP each  
No. speeds  
1/3  
3/4  
3/4  
3/4  
3/4  
1
1
1
1
1
RPM  
850  
6200  
1110  
7600  
1110  
8300  
1110  
9500  
1110  
13900  
Nominal total CFM  
BELT DRIVE EVAP FAN DATA  
Quantity  
1
1
1
1
1
Fan Size (Inch)  
Type  
12 x 12  
Centrifugal  
12 x 12  
15 x 15  
Centrifugal  
15 x 15  
Centrifugal  
15 x 15  
Centrifugal  
Centrifugal  
Motor Sheave  
Blower Sheave  
Belt  
1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56  
AK74  
A49  
AK64  
A49  
2
AK74  
A49  
AK61  
A49  
3
AK89  
A56  
2
AK74  
A54  
3
AK84  
A56  
2
AK74  
A54  
3
AK74  
A54  
3
BK77  
BX55  
5
Motor HP each  
RPM  
1-1/2  
1725  
56  
1-1/2  
1725  
56  
1725  
56  
1725  
56  
1725  
56  
1725  
56  
1725  
56  
1725  
56  
1725  
56  
1725  
184T  
Frame size  
FILTERS  
Quantity - Size  
4 - (24 x 16 x 2)2, 3 4 - (24 x 16 x 2)2, 3 4 - (24 x 20 x 2)2, 3 4 - (24 x 20 x 2)2, 3 4 - (24 x 20 x 2)2, 3  
4 - (24 x 16 x 4)4 4 - (24 x 16 x 4)4 4 - (24 x 20 x 4)4 4 - (24 x 20 x 4)4 4 - (24 x 20 x 4)4  
ST  
nd  
1.  
1
Stage 60% of 2 Stage  
2. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3  
3. 2 In. Pleated, Optional, MERV 7  
4. 4 In. Pleated, Optional, MERV 13  
Johnson Controls Unitary Products  
15  
528194-YTG-F-1210  
ZF078-150 Unit Limitations  
Unit Limitations  
Applied Voltage  
Size  
(Tons)  
Model  
ZF  
Unit Voltage  
Outdoor DB Temp  
Min  
187  
432  
540  
187  
432  
540  
187  
432  
540  
187  
432  
540  
187  
432  
540  
Max  
252  
504  
630  
252  
504  
630  
252  
504  
630  
252  
504  
630  
252  
504  
630  
Max (°F)  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
125  
208/230-3-60  
460-3-60  
078  
(6.5)  
575-3-60  
208/230-3-60  
460-3-60  
090  
(7.5)  
ZF  
575-3-60  
208/230-3-60  
460-3-60  
102  
(8.5)  
ZF  
575-3-60  
208/230-3-60  
460-3-60  
120  
(10)  
ZF  
575-3-60  
208/230-3-60  
460-3-60  
150  
(12.5)  
ZF  
575-3-60  
16  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Capacity Performance  
ZF078-150 Cooling Capacities  
ZF078 (6.5 Ton)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
WB  
(°F)  
CFM  
2
90  
85  
75°F  
34.0  
46.4  
58.7  
72.4  
38.0  
51.5  
65.1  
77.5  
79.2  
41.9  
56.7  
71.4  
82.5  
81.9  
45.9  
61.9  
77.8  
87.6  
84.6  
65.9  
82.9  
89.5  
86.5  
70.0  
80  
75  
70  
65  
90  
85  
85°F  
32.5  
44.2  
55.8  
69.4  
36.2  
49.1  
61.9  
73.1  
74.4  
40.0  
54.0  
68.1  
76.8  
76.9  
43.7  
58.9  
74.2  
80.4  
79.4  
63.1  
79.3  
82.0  
81.0  
67.3  
84.5  
83.6  
82.5  
105°F  
28.5  
39.3  
50.0  
61.3  
31.9  
43.8  
55.7  
63.3  
61.4  
35.3  
48.4  
61.4  
65.3  
63.3  
38.7  
52.9  
67.1  
67.3  
65.3  
57.1  
70.9  
68.5  
66.4  
61.3  
74.8  
69.7  
67.6  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
102.9  
94.8  
86.7  
79.2  
106.6  
98.2  
89.8  
82.0  
79.2  
110.2  
101.6  
92.9  
84.8  
81.9  
113.9  
104.9  
95.9  
87.6  
84.6  
107.2  
98.0  
89.5  
86.5  
109.4  
100.1  
91.4  
88.3  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
4.9  
5.0  
5.0  
5.0  
5.0  
4.9  
5.0  
5.0  
5.0  
5.0  
4.9  
5.0  
5.0  
5.0  
4.9  
5.0  
5.0  
5.0  
4.9  
41.5  
53.8  
66.1  
79.2  
46.7  
60.3  
73.8  
82.0  
79.2  
52.0  
66.7  
81.5  
84.8  
81.9  
57.2  
73.2  
89.2  
87.6  
84.6  
78.2  
94.6  
89.5  
86.5  
83.1  
26.6  
38.9  
51.3  
61.4  
29.3  
42.8  
56.3  
67.5  
71.1  
31.9  
46.7  
61.4  
73.6  
77.5  
34.5  
50.5  
66.5  
79.7  
83.9  
53.6  
70.6  
85.5  
86.1  
56.8  
74.7  
91.4  
88.3  
-
-
-
96.2  
88.3  
80.3  
72.8  
99.6  
91.4  
83.1  
75.4  
74.4  
103.0  
94.4  
85.9  
77.9  
76.9  
106.3  
97.5  
88.7  
80.4  
79.4  
99.5  
90.5  
82.0  
81.0  
101.4  
92.3  
83.6  
82.5  
5.6  
5.5  
5.5  
5.4  
5.6  
5.5  
5.5  
5.4  
5.4  
5.6  
5.5  
5.5  
5.4  
5.4  
5.6  
5.5  
5.5  
5.5  
5.4  
5.6  
5.5  
5.5  
5.4  
5.6  
5.5  
5.5  
5.4  
39.9  
51.6  
63.3  
72.8  
44.9  
57.8  
70.6  
75.4  
74.4  
49.9  
63.9  
78.0  
77.9  
76.9  
54.9  
70.1  
85.3  
80.4  
79.4  
75.3  
88.8  
82.0  
81.0  
80.4  
92.3  
83.6  
82.5  
25.0  
36.7  
48.4  
58.6  
27.6  
40.4  
53.3  
64.4  
66.4  
30.1  
44.1  
58.1  
70.3  
72.5  
32.6  
47.8  
63.0  
76.2  
78.5  
51.0  
67.2  
79.9  
80.5  
54.2  
71.4  
83.6  
82.5  
-
-
-
31.5  
43.8  
54.0  
-
-
-
29.3  
41.0  
51.1  
-
-
-
1625  
36.4  
46.6  
-
-
33.6  
43.7  
-
-
39.1  
36.3  
-
-
34.1  
47.6  
58.8  
62.4  
-
-
-
31.7  
44.6  
55.8  
57.7  
-
-
-
1950  
2275  
2600  
38.9  
50.0  
53.6  
-
-
35.9  
47.1  
49.1  
-
-
41.3  
38.4  
44.9  
40.4  
-
-
36.6  
51.4  
63.6  
67.5  
-
-
-
34.2  
48.2  
60.4  
62.5  
-
-
-
41.3  
53.5  
57.4  
-
-
38.3  
50.5  
52.6  
-
-
43.5  
40.6  
47.4  
42.7  
-
-
39.2  
55.2  
68.3  
72.6  
41.4  
58.4  
73.3  
73.8  
43.6  
61.6  
78.2  
75.1  
-
-
-
36.6  
51.8  
65.0  
67.3  
38.8  
55.0  
67.8  
68.4  
41.0  
58.3  
70.5  
69.4  
-
-
-
43.8  
57.0  
61.2  
-
40.7  
53.8  
56.2  
-
45.7  
49.9  
-
42.7  
45.0  
-
46.1  
61.0  
61.6  
-
-
42.9  
55.6  
56.2  
-
-
2925  
3250  
48.7  
49.3  
-
43.5  
44.1  
-
100.1 87.9  
48.4  
65.0  
61.9  
-
45.1  
57.4  
56.3  
-
91.4  
88.3  
91.4  
88.3  
95°F  
30.9  
41.9  
53.0  
66.5  
34.4  
46.6  
58.8  
68.7  
69.5  
38.0  
51.3  
64.7  
71.0  
71.8  
41.6  
56.0  
70.5  
73.3  
74.1  
60.3  
75.8  
74.6  
75.5  
64.6  
81.1  
75.9  
76.8  
51.8  
48.7  
44.2  
43.1  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
89.6  
81.7  
73.9  
66.5  
92.6  
84.5  
76.5  
68.7  
69.5  
95.7  
87.3  
79.0  
71.0  
71.8  
98.7  
90.1  
81.5  
73.3  
74.1  
91.7  
83.0  
74.6  
75.5  
93.4  
84.4  
75.9  
76.8  
6.1  
6.1  
6.0  
5.9  
6.1  
6.1  
6.0  
5.9  
5.9  
6.2  
6.1  
6.0  
5.9  
6.0  
6.2  
6.1  
6.0  
6.0  
6.0  
6.1  
6.0  
6.0  
6.0  
6.1  
6.0  
6.0  
6.0  
38.3  
49.3  
60.4  
66.5  
43.0  
55.2  
67.4  
68.7  
69.5  
47.8  
61.1  
74.4  
71.0  
71.8  
52.6  
67.0  
81.5  
73.3  
74.1  
72.4  
83.0  
74.6  
75.5  
77.7  
84.4  
75.9  
76.8  
23.5  
34.5  
45.6  
55.7  
25.8  
38.0  
50.2  
61.4  
61.7  
28.2  
41.5  
54.9  
67.0  
67.4  
30.6  
45.1  
59.5  
72.7  
73.1  
48.3  
63.8  
74.3  
74.9  
51.5  
68.1  
75.9  
76.8  
-
-
-
82.4  
74.8  
67.2  
61.3  
85.1  
77.3  
69.4  
63.3  
61.4  
87.8  
79.7  
71.7  
65.3  
63.3  
90.5  
82.2  
73.9  
67.3  
65.3  
83.6  
75.2  
68.5  
66.4  
85.1  
76.4  
69.7  
67.6  
6.7  
6.6  
6.5  
6.4  
6.7  
6.6  
6.5  
6.4  
6.4  
6.8  
6.7  
6.5  
6.4  
6.4  
6.8  
6.7  
6.6  
6.5  
6.4  
6.7  
6.6  
6.5  
6.4  
6.7  
6.6  
6.5  
6.4  
33.7  
46.6  
59.4  
61.3  
40.4  
52.3  
64.2  
63.3  
61.4  
47.1  
58.1  
69.0  
65.3  
63.3  
53.7  
63.8  
73.9  
67.3  
65.3  
69.1  
75.1  
68.5  
66.4  
74.3  
76.4  
69.7  
67.6  
21.2  
31.9  
42.7  
51.7  
23.4  
35.3  
47.2  
57.2  
53.9  
25.6  
38.7  
51.7  
62.6  
59.0  
27.8  
42.0  
56.2  
68.0  
64.1  
45.1  
60.4  
68.9  
65.9  
48.3  
64.6  
69.7  
67.6  
-
-
-
27.1  
38.2  
48.3  
-
-
-
24.6  
35.4  
44.4  
-
-
-
1625  
1950  
30.8  
40.9  
-
-
28.1  
37.1  
-
-
33.5  
29.8  
-
-
29.4  
41.6  
52.8  
53.1  
-
-
-
26.8  
38.7  
48.6  
45.4  
-
-
-
33.0  
44.2  
44.5  
-
-
30.2  
40.1  
36.9  
-
-
35.6  
31.6  
35.9  
28.4  
-
-
31.8  
45.1  
57.2  
57.6  
-
-
-
29.0  
42.0  
52.9  
49.3  
-
-
-
2275  
2600  
35.3  
47.4  
47.8  
-
-
32.3  
43.2  
39.6  
-
-
37.6  
33.5  
38.0  
29.9  
-
-
34.1  
48.5  
61.7  
62.1  
36.3  
51.7  
62.2  
62.9  
38.4  
55.0  
62.8  
63.7  
-
-
-
31.1  
45.3  
57.2  
53.2  
33.2  
48.4  
56.9  
53.9  
35.2  
51.5  
56.6  
54.5  
-
-
-
37.5  
50.7  
51.1  
-
34.4  
46.3  
42.4  
-
39.7  
40.1  
-
35.4  
31.5  
-
39.7  
50.2  
50.9  
-
-
36.5  
44.9  
41.9  
-
-
2925  
3250  
38.2  
38.8  
-
33.0  
30.0  
-
41.9  
49.7  
50.6  
-
38.5  
43.6  
41.5  
-
36.6  
37.5  
30.5  
28.5  
Johnson Controls Unitary Products  
17  
 
528194-YTG-F-1210  
ZF078 (6.5 Ton) (Continued)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
1
WB  
(°F)  
CFM  
1625  
2
2
90  
85  
115°F  
26.1  
36.6  
47.1  
56.1  
29.4  
41.0  
52.6  
57.8  
53.2  
32.6  
45.4  
58.2  
59.6  
54.8  
35.9  
49.8  
63.7  
61.4  
56.5  
53.9  
66.1  
62.4  
57.4  
58.0  
68.4  
63.4  
58.4  
80  
75  
70  
65  
90  
85  
125°F  
22.9  
33.9  
44.1  
50.9  
26.8  
38.1  
49.5  
52.4  
45.1  
30.8  
42.4  
54.9  
53.9  
46.4  
34.7  
46.7  
58.6  
55.5  
47.7  
50.7  
59.5  
56.3  
48.4  
54.7  
60.5  
57.2  
49.1  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
75.2  
67.9  
60.5  
56.1  
77.6  
70.0  
62.4  
57.8  
53.2  
80.0  
72.2  
64.3  
59.6  
54.8  
82.3  
74.3  
66.2  
61.4  
56.5  
75.5  
67.3  
62.4  
57.4  
76.8  
68.4  
63.4  
58.4  
7.3  
7.1  
7.0  
6.8  
7.3  
7.2  
7.0  
6.9  
6.8  
7.4  
7.2  
7.0  
6.9  
6.8  
7.4  
7.2  
7.1  
7.0  
6.9  
7.3  
7.1  
7.0  
6.9  
7.3  
7.1  
7.0  
6.9  
29.2  
43.8  
58.4  
56.1  
37.8  
49.4  
61.0  
57.8  
53.2  
46.3  
55.0  
63.6  
59.6  
54.8  
54.9  
60.6  
66.2  
61.4  
56.5  
65.8  
67.3  
62.4  
57.4  
71.0  
68.4  
63.4  
58.4  
18.9  
29.3  
39.8  
47.7  
20.9  
32.6  
44.2  
52.9  
46.1  
23.0  
35.8  
48.6  
58.2  
50.6  
25.1  
39.0  
52.9  
63.4  
55.2  
42.0  
57.0  
63.4  
56.8  
45.0  
61.1  
63.4  
58.4  
-
-
-
68.0  
60.9  
53.8  
50.9  
70.1  
62.7  
55.4  
52.4  
45.1  
72.1  
64.6  
57.0  
53.9  
46.4  
74.2  
66.4  
58.6  
55.5  
47.7  
67.4  
59.5  
56.3  
48.4  
68.5  
60.5  
57.2  
49.1  
7.9  
7.7  
7.5  
7.3  
7.9  
7.7  
7.5  
7.4  
7.2  
8.0  
7.8  
7.6  
7.4  
7.2  
8.0  
7.8  
7.6  
7.5  
7.3  
7.8  
7.6  
7.5  
7.3  
7.9  
7.7  
7.5  
7.4  
28.3  
41.0  
53.8  
50.9  
37.5  
46.5  
55.4  
52.4  
45.1  
46.8  
51.9  
57.0  
53.9  
46.4  
56.0  
57.3  
58.6  
55.5  
47.7  
62.5  
59.5  
56.3  
48.4  
67.6  
60.5  
57.2  
49.1  
16.6  
26.8  
36.9  
43.7  
18.5  
29.8  
41.2  
48.7  
38.3  
20.4  
32.9  
45.4  
53.8  
42.2  
22.3  
36.0  
49.7  
55.5  
46.2  
38.9  
53.6  
56.3  
47.7  
41.7  
57.6  
57.2  
49.1  
-
-
-
22.1  
32.6  
40.5  
-
-
-
19.6  
29.8  
36.6  
-
-
-
25.4  
33.3  
-
-
22.7  
29.4  
-
-
26.0  
22.3  
-
-
24.2  
35.8  
44.5  
37.7  
-
-
-
21.5  
32.9  
40.4  
29.9  
-
-
-
1950  
2275  
2600  
27.4  
36.1  
29.2  
-
-
24.5  
32.1  
21.6  
-
-
27.7  
23.8  
20.8  
13.3  
-
-
26.2  
39.0  
48.6  
41.0  
-
-
-
23.4  
35.9  
44.3  
32.7  
-
-
-
29.4  
39.0  
31.4  
-
-
26.4  
34.8  
23.2  
-
-
29.4  
25.3  
21.8  
13.7  
-
-
28.2  
42.1  
52.6  
44.4  
30.1  
45.1  
51.5  
44.9  
32.0  
48.1  
50.4  
45.4  
-
-
-
25.3  
39.0  
48.1  
35.6  
27.0  
41.8  
46.2  
35.9  
28.8  
44.6  
44.3  
36.2  
-
-
-
31.4  
41.9  
33.6  
-
28.3  
37.4  
24.9  
-
31.1  
22.8  
-
26.8  
14.2  
-
33.2  
39.7  
33.0  
-
-
30.0  
34.4  
24.1  
-
-
2925  
3250  
27.8  
21.1  
-
22.6  
12.3  
-
35.1  
37.5  
32.4  
-
31.7  
31.3  
23.3  
-
24.5  
19.4  
18.4  
10.3  
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower  
Performance Table for the kW of the supply air blower motor.  
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.  
18  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
ZF090 (7.5 Ton)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
WB  
CFM  
2
(°F)  
90  
85  
75°F  
41.4  
55.1  
68.8  
82.1  
45.0  
59.7  
74.5  
87.4  
95.1  
48.5  
64.3  
80.1  
92.8  
97.4  
52.1  
69.0  
85.8  
98.2  
99.8  
73.6  
80  
75  
70  
65  
90  
85  
85°F  
39.2  
52.3  
65.3  
79.2  
42.7  
56.8  
70.8  
83.1  
88.3  
46.2  
61.3  
76.4  
87.1  
90.5  
49.7  
65.8  
81.9  
91.0  
92.7  
70.6  
87.8  
93.5  
95.3  
75.5  
80  
75  
70  
65  
77  
119.9  
110.5  
101.1  
91.2  
6.0  
6.0  
6.0  
6.1  
6.0  
6.0  
6.1  
6.1  
6.0  
6.1  
6.1  
6.1  
6.1  
6.0  
6.1  
6.1  
6.1  
6.1  
6.1  
6.1  
6.1  
6.1  
6.0  
6.1  
6.1  
6.1  
6.0  
49.5  
63.2  
76.9  
91.2  
54.1  
68.8  
83.6  
93.6  
95.1  
58.7  
74.5  
90.3  
95.9  
97.4  
63.2  
80.1  
97.0  
98.2  
99.8  
85.8  
33.3  
47.0  
60.7  
72.7  
35.8  
50.6  
65.3  
78.3  
85.3  
38.4  
54.2  
70.0  
83.9  
91.4  
41.0  
57.8  
74.7  
89.5  
97.5  
61.4  
79.4  
-
-
-
112.2  
103.0  
93.7  
6.6  
6.6  
6.6  
6.6  
6.7  
6.7  
6.6  
6.6  
6.5  
6.7  
6.7  
6.7  
6.6  
6.6  
6.8  
6.7  
6.7  
6.7  
6.6  
6.7  
6.7  
6.7  
6.6  
6.7  
6.7  
6.7  
6.6  
47.2  
60.2  
73.2  
84.5  
51.8  
65.8  
79.8  
86.7  
88.3  
56.3  
71.4  
86.4  
88.8  
90.5  
60.9  
76.9  
93.0  
91.0  
92.7  
82.8  
99.8  
93.5  
95.3  
88.7  
31.3  
44.3  
57.3  
68.8  
33.7  
47.8  
61.8  
74.1  
79.5  
36.2  
51.2  
66.3  
79.5  
85.2  
38.6  
54.7  
70.7  
84.8  
91.0  
58.4  
75.6  
90.5  
94.4  
62.2  
80.5  
96.1  
97.9  
-
-
-
72  
38.8  
52.5  
64.6  
-
-
-
36.4  
49.4  
60.8  
-
-
-
1875  
67  
44.4  
56.4  
-
-
41.4  
52.9  
-
-
62  
77  
72  
48.3  
84.5  
44.9  
123.0  
113.3  
103.6  
93.6  
-
115.1  
105.6  
96.1  
-
41.4  
56.2  
69.2  
76.1  
-
-
-
38.8  
52.8  
65.1  
70.5  
-
-
-
2250  
2625  
3000  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
47.1  
60.0  
67.0  
-
-
43.8  
56.1  
61.5  
-
-
50.9  
86.7  
47.1  
95.1  
57.9  
88.3  
52.5  
126.0  
116.1  
106.2  
95.9  
-
118.0  
108.2  
98.5  
-
44.1  
59.9  
73.8  
81.2  
-
-
-
41.2  
56.2  
69.4  
75.2  
-
-
-
49.7  
63.7  
71.1  
-
-
46.1  
59.3  
65.1  
-
-
53.5  
88.8  
49.3  
97.4  
61.0  
90.5  
55.0  
129.1  
118.9  
108.8  
98.2  
-
120.8  
110.9  
100.9  
91.0  
-
46.7  
63.6  
78.4  
86.3  
49.3  
67.2  
84.6  
-
-
-
43.5  
59.6  
73.7  
79.9  
46.2  
63.4  
78.3  
82.2  
48.9  
67.2  
82.8  
84.6  
-
-
-
52.4  
67.3  
75.2  
-
48.5  
62.6  
68.7  
-
56.1  
64.1  
-
51.4  
57.6  
-
99.8  
92.7  
122.5  
112.0  
101.1  
102.8  
126.1  
115.3  
104.1  
105.8  
114.0  
103.7  
93.5  
106.1 91.5  
101.1 101.1 96.8  
55.0  
72.5  
77.3  
-
-
51.2  
66.1  
70.0  
-
-
3375  
3750  
60.3  
65.1  
-
53.9  
57.9  
-
102.8 102.8 101.6 89.4  
95.3  
91.5  
78.3  
65.1  
84.1  
51.9  
70.9  
117.1  
106.5  
96.1  
115.3 97.3  
57.6  
77.7  
79.4  
-
106.5 93.7  
53.9  
69.6  
71.4  
-
104.1 104.1 104.1 90.9  
105.8 105.8 105.8 92.6  
95°F  
64.5  
66.1  
96.1  
97.9  
96.1  
97.9  
105°F  
33.5  
46.1  
58.6  
70.3  
36.7  
50.2  
63.8  
72.3  
75.0  
39.8  
54.4  
69.0  
74.3  
76.9  
42.9  
58.5  
74.1  
76.4  
78.7  
63.0  
79.4  
78.2  
80.5  
67.5  
84.6  
79.9  
82.4  
56.3  
58.1  
97.9  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
104.6  
95.4  
86.3  
77.8  
107.2  
97.9  
88.6  
79.8  
81.6  
109.9  
100.4  
90.8  
81.8  
83.6  
112.6  
102.8  
93.0  
83.8  
85.7  
105.4  
95.4  
86.0  
87.9  
108.1  
97.8  
88.1  
90.1  
7.3  
7.2  
7.1  
7.0  
7.3  
7.3  
7.2  
7.1  
7.1  
7.4  
7.3  
7.2  
7.1  
7.1  
7.4  
7.4  
7.3  
7.2  
7.1  
7.4  
7.3  
7.2  
7.2  
7.4  
7.3  
7.2  
7.2  
44.9  
57.2  
69.6  
77.8  
49.4  
62.8  
76.1  
79.8  
81.6  
54.0  
68.3  
82.6  
81.8  
83.6  
58.5  
73.8  
89.1  
83.8  
85.7  
79.9  
93.4  
86.0  
87.9  
86.0  
97.8  
88.1  
90.1  
37.1  
49.5  
61.8  
76.3  
40.5  
53.9  
67.2  
78.8  
81.6  
44.0  
58.3  
72.6  
81.3  
83.6  
47.4  
62.7  
77.9  
83.8  
85.7  
67.6  
84.1  
86.0  
87.9  
72.6  
90.2  
88.1  
90.1  
29.3  
41.7  
54.0  
64.8  
31.6  
45.0  
58.3  
69.9  
73.7  
34.0  
48.2  
62.5  
75.0  
79.1  
36.3  
51.5  
66.8  
80.2  
84.5  
55.4  
71.8  
84.1  
87.3  
59.3  
76.9  
88.1  
90.1  
-
-
-
95.9  
87.2  
78.5  
71.0  
98.3  
89.4  
80.5  
72.8  
75.0  
100.8  
91.6  
82.5  
74.6  
76.9  
103.2  
93.9  
84.5  
76.4  
78.7  
96.0  
86.5  
78.2  
80.5  
98.2  
88.4  
79.9  
82.4  
7.9  
7.8  
7.6  
7.5  
8.0  
7.8  
7.7  
7.6  
7.6  
8.0  
7.9  
7.8  
7.6  
7.6  
8.1  
7.9  
7.8  
7.7  
7.7  
8.0  
7.8  
7.7  
7.7  
8.0  
7.9  
7.7  
7.7  
40.1  
53.9  
67.7  
71.0  
45.5  
59.1  
72.7  
72.8  
75.0  
50.9  
64.3  
77.6  
74.6  
76.9  
56.3  
69.4  
82.5  
76.4  
78.7  
75.0  
85.5  
78.2  
80.5  
80.6  
88.4  
79.9  
82.4  
25.7  
38.2  
50.8  
60.2  
27.8  
41.4  
54.9  
65.1  
67.2  
29.9  
44.5  
59.1  
70.0  
72.3  
32.0  
47.6  
63.2  
74.9  
77.3  
51.0  
67.8  
77.4  
79.9  
54.5  
72.4  
79.9  
82.4  
-
-
-
33.9  
46.3  
57.1  
-
-
-
30.4  
43.0  
52.3  
-
-
-
1875  
2250  
38.5  
49.3  
-
-
35.1  
44.5  
-
-
41.5  
36.7  
-
-
36.1  
49.4  
61.0  
64.8  
-
-
-
32.5  
46.1  
56.2  
58.3  
-
-
-
40.5  
52.2  
56.0  
-
-
37.2  
47.3  
49.5  
-
-
43.3  
38.5  
47.1  
40.6  
-
-
38.2  
52.5  
65.0  
69.1  
-
-
-
34.6  
49.2  
60.1  
62.4  
-
-
-
2625  
3000  
42.5  
55.0  
59.1  
-
-
39.3  
50.2  
52.5  
-
-
45.0  
40.3  
49.1  
42.6  
-
-
40.4  
55.7  
69.0  
73.4  
43.2  
59.6  
71.9  
75.0  
46.0  
63.5  
74.8  
76.7  
-
-
-
36.7  
52.3  
64.0  
66.4  
39.1  
55.8  
65.4  
67.9  
41.5  
59.4  
66.9  
69.4  
-
-
-
44.5  
57.9  
62.2  
-
41.4  
53.0  
55.5  
-
46.8  
51.1  
-
42.1  
44.6  
-
47.4  
59.7  
62.8  
-
-
43.9  
53.5  
55.9  
-
-
3375  
3750  
47.4  
50.6  
-
41.5  
43.9  
-
50.2  
61.4  
63.4  
-
46.3  
53.9  
56.3  
-
48.1  
50.1  
40.9  
43.3  
Johnson Controls Unitary Products  
19  
528194-YTG-F-1210  
ZF090 (7.5 Ton) (Continued)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
1
WB  
(°F)  
CFM  
1875  
2
2
90  
85  
115°F  
30.0  
42.7  
55.4  
64.2  
32.8  
46.6  
60.4  
65.8  
68.5  
35.6  
50.5  
65.4  
67.4  
70.1  
38.4  
54.4  
70.3  
68.9  
71.8  
58.4  
74.7  
70.3  
73.2  
62.4  
79.1  
71.7  
74.7  
80  
75  
70  
65  
90  
85  
125°F  
26.4  
39.3  
52.3  
57.4  
28.9  
43.0  
57.0  
58.7  
61.9  
31.4  
46.6  
61.8  
60.1  
63.4  
33.9  
50.2  
66.5  
61.5  
64.8  
53.8  
68.6  
62.5  
65.9  
57.3  
69.8  
63.6  
67.0  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
87.3  
79.0  
70.7  
64.2  
89.5  
81.0  
72.5  
65.8  
68.5  
91.6  
82.9  
74.3  
67.4  
70.1  
93.8  
84.9  
76.0  
68.9  
71.8  
86.6  
77.6  
70.3  
73.2  
88.3  
79.1  
71.7  
74.7  
8.6  
8.4  
8.1  
8.0  
8.6  
8.4  
8.2  
8.1  
8.0  
8.7  
8.5  
8.3  
8.1  
8.1  
8.7  
8.5  
8.3  
8.2  
8.2  
8.6  
8.4  
8.2  
8.2  
8.6  
8.4  
8.2  
8.2  
35.4  
50.6  
65.8  
64.2  
41.6  
55.4  
69.2  
65.8  
68.5  
47.9  
60.2  
72.6  
67.4  
70.1  
54.1  
65.1  
76.0  
68.9  
71.8  
70.1  
77.6  
70.3  
73.2  
75.2  
79.1  
71.7  
74.7  
22.1  
34.8  
47.5  
55.5  
24.0  
37.8  
51.6  
60.2  
60.7  
25.8  
40.7  
55.6  
64.9  
65.4  
27.7  
43.7  
59.6  
69.6  
70.2  
46.7  
63.8  
70.7  
72.4  
49.7  
67.9  
71.7  
74.7  
-
-
-
78.6  
70.8  
62.9  
57.4  
80.6  
72.5  
64.5  
58.7  
61.9  
82.5  
74.2  
66.0  
60.1  
63.4  
84.4  
75.9  
67.5  
61.5  
64.8  
77.2  
68.6  
62.5  
65.9  
78.5  
69.8  
63.6  
67.0  
9.2  
8.9  
8.6  
8.5  
9.3  
9.0  
8.7  
8.5  
8.5  
9.3  
9.1  
8.8  
8.6  
8.6  
9.4  
9.1  
8.9  
8.7  
8.7  
9.2  
8.9  
8.7  
8.7  
9.2  
8.9  
8.8  
8.8  
31.6  
47.3  
62.9  
57.4  
39.1  
51.8  
64.5  
58.7  
61.9  
46.5  
56.2  
66.0  
60.1  
63.4  
53.9  
60.7  
67.5  
61.5  
64.8  
65.2  
68.6  
62.5  
65.9  
69.8  
69.8  
63.6  
67.0  
18.5  
31.4  
44.3  
50.8  
20.1  
34.2  
48.2  
55.3  
54.2  
21.8  
36.9  
52.1  
59.8  
58.6  
23.4  
39.7  
56.0  
61.5  
63.0  
42.3  
59.7  
62.5  
65.0  
44.9  
63.4  
63.6  
67.0  
-
-
-
26.9  
39.6  
47.6  
-
-
-
23.4  
36.3  
42.9  
-
-
-
31.7  
39.7  
-
-
28.4  
34.9  
-
-
31.8  
27.0  
-
-
28.9  
42.7  
51.4  
51.9  
-
-
-
25.4  
39.4  
46.5  
45.4  
-
-
-
2250  
2625  
3000  
33.9  
42.5  
43.0  
-
-
30.6  
37.7  
36.6  
-
-
33.7  
28.9  
34.2  
27.7  
-
-
30.9  
45.8  
55.1  
55.7  
-
-
-
27.3  
42.5  
50.2  
48.9  
-
-
-
36.0  
45.4  
45.9  
-
-
32.8  
40.5  
39.3  
-
-
35.6  
30.9  
36.1  
29.6  
-
-
32.9  
48.9  
58.9  
59.5  
35.0  
52.0  
59.0  
60.7  
37.0  
55.2  
59.0  
62.0  
-
-
-
29.2  
45.5  
53.8  
52.5  
30.9  
48.3  
52.5  
53.5  
32.5  
51.0  
51.2  
54.6  
-
-
-
38.2  
48.2  
48.7  
-
35.0  
43.3  
42.0  
-
37.5  
38.0  
-
32.8  
31.5  
-
40.3  
47.2  
49.0  
-
-
36.8  
41.0  
42.1  
-
-
3375  
3750  
35.5  
37.3  
-
29.6  
30.6  
-
42.4  
46.3  
49.3  
-
38.6  
38.7  
42.2  
-
33.6  
36.5  
26.3  
29.8  
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower  
Performance Table for the kW of the supply air blower motor.  
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.  
20  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
ZF102 (8.5 Ton)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
WB  
CFM  
2
(°F)  
90  
85  
75°F  
45.9  
61.3  
76.7  
80  
75  
70  
65  
90  
85  
85°F  
43.2  
57.8  
72.5  
88.9  
48.3  
64.6  
80.8  
94.8  
98.0  
53.5  
71.3  
80  
75  
70  
65  
77  
137.6  
125.2  
112.8  
103.0  
142.9  
130.1  
117.2  
107.0  
106.1  
148.3  
134.9  
121.6  
111.0  
110.1  
153.7  
139.8  
126.0  
115.0  
114.1  
144.9  
130.5  
119.2  
118.2  
149.9  
135.1  
123.4  
122.4  
6.9  
6.9  
6.8  
6.7  
7.0  
6.9  
6.9  
6.8  
6.7  
7.1  
7.0  
6.9  
6.8  
6.8  
7.1  
7.1  
7.0  
6.9  
6.8  
7.1  
7.0  
6.9  
6.8  
7.1  
7.0  
6.9  
6.8  
55.6  
71.0  
86.3  
36.2  
51.6  
67.0  
79.1  
39.9  
56.8  
73.8  
87.1  
-
-
-
126.6  
115.4  
104.3  
95.3  
7.7  
7.5  
7.4  
7.3  
7.7  
7.6  
7.5  
7.3  
7.3  
7.8  
7.7  
7.6  
7.4  
7.4  
7.9  
7.8  
7.6  
7.5  
7.5  
7.8  
7.7  
7.5  
7.5  
7.8  
7.7  
7.5  
7.5  
52.6  
67.3  
81.9  
95.3  
59.3  
75.5  
91.7  
99.1  
99.1  
66.0  
83.8  
33.7  
48.4  
63.1  
75.7  
37.4  
53.6  
69.8  
83.9  
87.1  
41.0  
58.8  
76.6  
-
-
-
72  
41.9  
57.3  
69.4  
-
-
-
39.0  
53.6  
66.3  
-
-
-
2125  
67  
47.6  
59.7  
-
-
44.2  
56.9  
-
-
62  
77  
72  
103.0 90.1  
50.0  
47.5  
62.1  
79.1  
96.0  
51.0  
67.9  
84.9  
-
131.6  
120.0  
108.4  
99.1  
-
45.7  
62.7  
76.0  
82.6  
-
-
-
42.6  
58.9  
72.9  
76.1  
-
-
-
2550  
2975  
3400  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
51.6  
64.9  
71.5  
-
-
47.9  
61.9  
65.1  
-
-
107.0 98.4  
53.8  
51.0  
106.1 104.8 93.7  
60.4  
99.1  
54.2  
68.6  
87.1  
56.1  
74.6  
43.6  
62.1  
80.6  
-
136.7  
124.6  
112.6  
102.9  
102.9  
141.7  
129.2  
116.7  
106.7  
106.7  
131.5  
118.8  
108.6  
108.6  
133.8  
120.8  
110.5  
110.4  
-
49.6  
68.0  
82.5  
-
-
46.3  
64.1  
79.5  
83.0  
-
-
-
105.6 93.1  
55.5  
70.0  
77.3  
-
-
101.6 89.1  
51.6  
67.0  
70.5  
-
-
111.0 106.7 95.1  
57.5  
102.9 100.8 92.0  
102.9 102.3 95.5  
54.5  
110.1 109.4 102.4 89.8  
64.8  
58.0  
75.1  
95.2  
61.2  
81.3  
47.3  
67.3  
-
-
72.6  
92.0  
58.6  
78.0  
44.6  
64.0  
83.4  
-
53.4  
73.4  
-
-
-
50.0  
69.3  
-
-
-
115.3 101.3 87.4  
59.5  
75.2  
83.1  
-
111.4 97.4  
55.3  
72.1  
75.9  
-
115.0 115.0 103.1 89.1  
114.1 114.1 111.0 97.1  
61.2  
69.2  
-
106.7 106.7 100.1 86.1  
106.7 106.7 103.9 89.9  
58.1  
61.9  
-
101.8 86.7  
71.5  
56.4  
77.7  
98.5  
83.2  
68.0  
52.7  
73.3  
125.2 108.0 92.9  
62.6  
83.0  
-
116.1 103.8 88.6  
58.1  
74.8  
76.7  
-
-
3825  
4250  
119.2 119.2 113.2 98.1  
67.9  
71.4  
-
108.6 108.6 105.3 90.1  
108.6 108.6 107.2 91.9  
59.6  
61.5  
-
118.2 118.2 116.7 101.6 86.5  
108.3 92.0  
75.8  
59.5  
82.1  
-
104.9 88.5  
72.0  
55.5  
77.3  
135.1 114.6 98.3  
65.8  
-
120.8 110.3 93.8  
60.9  
77.6  
77.5  
-
123.4 123.4 123.4 107.1 90.8  
122.4 122.4 122.4 106.2 89.9  
95°F  
74.6  
73.6  
110.5 110.5 110.5 94.0  
110.4 110.4 110.4 94.0  
105°F  
61.1  
61.1  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
115.6  
105.6  
95.7  
8.4  
8.2  
8.1  
7.9  
8.4  
8.3  
8.1  
7.9  
8.0  
8.5  
8.4  
8.2  
8.0  
8.0  
8.6  
8.4  
8.3  
8.1  
8.1  
8.5  
8.3  
8.1  
8.1  
8.5  
8.3  
8.1  
8.2  
49.6  
63.6  
77.5  
87.6  
56.4  
72.0  
87.5  
91.2  
92.0  
63.3  
80.4  
97.5  
94.8  
95.7  
70.1  
88.8  
40.4  
54.4  
68.3  
87.6  
45.6  
61.2  
76.7  
91.2  
91.2  
50.8  
67.9  
85.1  
94.8  
95.2  
56.0  
74.7  
31.2  
45.2  
59.1  
72.4  
34.8  
50.3  
65.9  
80.7  
80.4  
38.4  
55.5  
72.6  
88.9  
88.6  
41.9  
60.6  
79.4  
97.2  
96.8  
64.4  
84.3  
97.4  
97.6  
68.2  
-
-
-
106.8  
97.2  
87.5  
81.4  
110.8  
100.8  
90.7  
84.4  
85.1  
114.8  
104.4  
94.0  
87.4  
88.2  
118.8  
108.0  
97.2  
90.5  
91.2  
106.7  
96.1  
89.4  
90.1  
105.4  
94.9  
88.3  
89.0  
9.1  
8.8  
8.6  
8.4  
9.2  
8.9  
8.7  
8.5  
8.5  
9.3  
9.0  
8.8  
8.6  
8.6  
9.3  
9.1  
8.9  
8.7  
8.7  
9.2  
8.9  
8.7  
8.8  
9.2  
9.0  
8.8  
8.8  
44.1  
60.7  
77.2  
81.4  
53.5  
68.7  
83.9  
84.4  
85.1  
62.9  
76.7  
90.6  
87.4  
88.2  
72.3  
84.8  
97.2  
90.5  
91.2  
91.0  
96.1  
89.4  
90.1  
97.1  
94.9  
88.3  
89.0  
37.9  
51.5  
65.2  
81.4  
42.8  
58.0  
73.1  
84.4  
84.7  
47.6  
64.4  
81.1  
87.4  
88.0  
52.5  
70.8  
89.1  
90.5  
91.2  
75.7  
91.8  
89.4  
90.1  
80.6  
94.6  
88.3  
89.0  
28.7  
42.4  
56.0  
67.5  
32.0  
47.2  
62.4  
75.2  
74.1  
35.3  
52.0  
68.8  
82.9  
81.6  
38.6  
56.9  
75.2  
90.6  
89.2  
60.5  
79.9  
89.4  
89.1  
64.1  
84.7  
88.3  
89.0  
-
-
-
36.0  
50.0  
63.2  
-
-
-
33.2  
46.8  
58.3  
-
-
-
2125  
2550  
40.8  
54.1  
-
-
37.7  
49.1  
-
-
87.6  
44.9  
40.0  
120.3  
110.0  
99.7  
-
-
39.5  
55.1  
69.8  
69.6  
-
-
-
36.4  
51.6  
64.4  
63.3  
-
-
-
44.3  
59.0  
58.8  
-
-
40.9  
53.6  
52.5  
-
-
91.2  
48.2  
42.9  
92.0  
47.9  
41.8  
125.0  
114.3  
103.6  
94.8  
-
-
43.0  
60.2  
76.5  
76.2  
-
-
-
39.7  
56.4  
70.5  
69.3  
-
-
-
2975  
3400  
47.7  
64.0  
63.7  
-
-
44.1  
58.2  
56.9  
-
-
51.6  
45.8  
95.7  
51.3  
44.6  
129.8  
118.6  
107.5  
98.4  
-
-
46.5  
65.3  
83.1  
82.7  
49.0  
68.9  
82.0  
82.3  
51.5  
72.6  
80.9  
81.8  
-
-
-
42.9  
61.2  
76.6  
75.3  
45.2  
64.7  
74.2  
73.9  
47.5  
68.2  
71.7  
72.5  
-
-
-
107.5 93.4  
51.2  
69.0  
68.6  
-
47.3  
62.7  
61.3  
-
98.4  
99.3  
95.2  
98.4  
99.3  
79.8  
54.9  
54.6  
-
48.7  
47.4  
-
99.3  
118.1  
107.1  
98.0  
107.1 99.7  
53.6  
66.6  
66.9  
-
-
49.5  
58.9  
58.6  
-
-
3825  
4250  
98.0  
98.9  
98.0  
98.9  
51.3  
51.5  
-
43.7  
43.4  
-
98.9  
117.7  
106.6  
97.6  
101.5 84.9  
106.6 105.9 89.2  
55.9  
64.3  
65.1  
-
51.6  
55.2  
56.0  
-
97.6  
98.5  
97.6  
98.5  
97.6  
98.5  
47.6  
48.5  
38.7  
39.4  
98.5  
Johnson Controls Unitary Products  
21  
528194-YTG-F-1210  
ZF102 (8.5 Ton) (Continued)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
1
WB  
(°F)  
CFM  
2125  
2
2
90  
85  
115°F  
35.3  
48.7  
62.0  
75.1  
39.9  
54.7  
69.6  
77.6  
78.2  
44.5  
60.8  
77.2  
80.0  
80.7  
49.0  
66.9  
84.8  
82.5  
83.2  
71.6  
84.0  
80.7  
81.4  
76.3  
83.2  
78.9  
79.6  
80  
75  
70  
65  
90  
85  
125°F  
30.9  
45.8  
58.8  
68.8  
37.0  
51.5  
66.1  
70.7  
71.3  
43.2  
57.3  
73.3  
72.6  
73.3  
49.3  
63.0  
76.7  
74.5  
75.2  
67.6  
74.1  
72.1  
72.7  
72.1  
71.5  
69.6  
70.2  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
98.1  
88.7  
79.2  
75.1  
101.4  
91.6  
81.8  
77.6  
78.2  
104.6  
94.5  
84.4  
80.0  
80.7  
107.8  
97.4  
87.0  
82.5  
83.2  
95.3  
85.1  
80.7  
81.4  
93.2  
83.2  
78.9  
79.6  
9.8  
9.5  
9.2  
9.0  
9.9  
9.6  
9.3  
9.1  
9.1  
10.0  
9.7  
9.4  
9.2  
9.2  
10.1  
9.8  
9.5  
9.3  
9.3  
9.8  
9.5  
9.3  
9.4  
9.9  
9.6  
9.4  
9.4  
38.6  
57.8  
77.0  
75.1  
50.6  
65.5  
80.3  
77.6  
78.2  
62.6  
73.1  
83.6  
80.0  
80.7  
74.5  
80.8  
87.0  
82.5  
83.2  
86.8  
85.1  
80.7  
81.4  
92.7  
83.2  
78.9  
79.6  
26.2  
39.5  
52.8  
62.5  
29.2  
44.0  
58.9  
69.7  
67.7  
32.2  
48.6  
64.9  
76.8  
74.7  
35.2  
53.1  
71.0  
84.0  
81.6  
56.5  
75.6  
81.5  
80.6  
59.9  
80.2  
78.9  
79.6  
-
-
-
89.4  
80.2  
70.9  
68.8  
91.9  
82.4  
72.9  
70.7  
71.3  
94.4  
84.6  
74.8  
72.6  
73.3  
96.8  
86.8  
76.7  
74.5  
75.2  
83.9  
74.1  
72.1  
72.7  
81.0  
71.5  
69.6  
70.2  
10.5  
10.1  
9.7  
38.9  
54.9  
70.9  
68.8  
51.5  
62.2  
72.9  
70.7  
71.3  
64.1  
69.5  
74.8  
72.6  
73.3  
76.7  
76.7  
76.7  
74.5  
75.2  
82.5  
74.1  
72.1  
72.7  
81.0  
71.5  
69.6  
70.2  
23.7  
36.7  
49.7  
57.6  
26.4  
40.9  
55.4  
64.2  
61.4  
29.1  
45.1  
61.1  
70.8  
67.7  
31.8  
49.3  
66.8  
74.5  
74.1  
52.6  
71.2  
72.1  
72.1  
55.8  
71.5  
69.6  
70.2  
-
-
-
30.4  
43.7  
53.4  
-
-
-
27.6  
40.6  
48.4  
-
-
-
34.6  
44.2  
-
-
31.4  
39.3  
-
-
35.1  
9.6  
30.2  
-
10.6  
10.2  
9.8  
-
33.3  
48.2  
59.0  
57.0  
-
-
-
30.2  
44.8  
53.5  
50.7  
-
-
-
2550  
2975  
3400  
37.5  
48.3  
46.3  
-
-
34.1  
42.9  
40.1  
-
-
37.6  
9.7  
32.2  
35.6  
9.7  
29.4  
-
10.7  
10.3  
9.9  
-
36.3  
52.7  
64.6  
62.4  
-
-
-
32.9  
48.9  
58.6  
55.6  
-
-
-
40.4  
52.3  
50.2  
-
-
36.8  
46.4  
43.4  
-
-
40.0  
9.8  
34.3  
37.9  
9.8  
31.2  
-
10.8  
10.4  
10.1  
9.9  
-
39.3  
57.2  
70.2  
67.8  
41.4  
60.5  
66.3  
65.5  
43.5  
63.8  
62.5  
63.2  
-
-
-
35.6  
53.1  
63.7  
60.4  
37.6  
56.2  
58.5  
57.1  
39.6  
59.3  
53.3  
53.9  
-
-
-
43.3  
56.3  
54.0  
-
39.4  
50.0  
46.7  
-
42.5  
40.2  
-
36.3  
33.0  
-
9.9  
10.5  
10.1  
10.0  
10.0  
10.6  
10.2  
10.0  
10.1  
45.3  
51.2  
50.4  
-
-
41.2  
43.5  
42.1  
-
-
3825  
4250  
36.1  
35.3  
-
28.5  
27.2  
-
47.4  
46.1  
46.8  
-
43.1  
37.0  
37.6  
-
29.7  
30.4  
20.8  
21.4  
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower  
Performance Table for the kW of the supply air blower motor.  
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.  
22  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
ZF120 (10 Ton)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
WB  
CFM  
2
(°F)  
90  
85  
75°F  
56.3  
72.9  
80  
75  
70  
65  
90  
85  
85°F  
51.8  
68.3  
84.8  
80  
75  
70  
65  
77  
165.2  
149.2  
133.2  
121.8  
170.9  
154.3  
137.7  
125.9  
120.2  
176.6  
159.4  
142.3  
130.1  
124.2  
182.2  
164.5  
146.8  
134.3  
128.2  
168.0  
149.9  
137.1  
130.9  
171.4  
153.0  
139.9  
133.5  
7.4  
7.5  
7.5  
7.5  
7.4  
7.4  
7.4  
7.5  
7.4  
7.4  
7.4  
7.4  
7.5  
7.4  
7.3  
7.4  
7.4  
7.4  
7.4  
7.4  
7.4  
7.4  
7.4  
7.4  
7.4  
7.5  
7.4  
67.4  
84.0  
45.3  
61.8  
78.4  
-
-
-
153.8  
138.9  
124.0  
112.8  
159.0  
143.5  
128.1  
116.5  
112.6  
164.1  
148.2  
132.3  
120.3  
116.3  
169.2  
152.8  
136.4  
124.1  
119.9  
155.6  
138.9  
126.3  
122.1  
158.4  
141.4  
128.6  
124.3  
8.3  
8.3  
8.2  
8.2  
8.3  
8.3  
8.2  
8.2  
8.2  
8.3  
8.3  
8.2  
8.2  
8.2  
8.3  
8.3  
8.2  
8.2  
8.2  
8.3  
8.3  
8.2  
8.2  
8.3  
8.3  
8.2  
8.2  
62.7  
79.2  
95.7  
40.9  
57.4  
73.9  
-
-
-
72  
50.8  
67.3  
82.0  
-
-
-
46.5  
63.0  
77.1  
-
-
-
2500  
67  
100.5 89.4  
56.3  
70.9  
-
-
52.1  
66.2  
-
-
62  
77  
72  
121.8 105.9 93.0  
59.8  
112.8 103.2 88.0  
55.3  
76.4  
94.5  
63.0  
81.2  
49.7  
67.8  
86.0  
-
71.2  
89.4  
58.2  
76.4  
45.2  
63.4  
81.6  
-
54.5  
72.7  
-
-
50.4  
68.5  
84.1  
-
-
3000  
3500  
4000  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
112.6 99.3  
59.3  
75.4  
83.0  
-
-
107.6 94.6  
55.5  
71.1  
75.8  
-
-
125.9 115.4 102.0 88.7  
120.2 120.2 109.7 96.3  
62.1  
116.5 110.1 97.1  
58.0  
69.7  
112.6 112.6 101.9 88.9  
62.8  
85.3  
69.7  
54.1  
73.9  
-
-
79.7  
99.6  
64.6  
84.5  
49.4  
69.3  
-
-
105.0 89.5  
58.3  
78.0  
-
-
54.2  
74.1  
-
-
124.8 109.2 93.6  
62.4  
79.9  
-
119.5 104.3 89.2  
58.9  
75.9  
81.1  
-
-
130.1 124.8 111.1 95.5  
64.3  
120.3 117.1 106.2 91.1  
116.3 116.3 111.4 96.3  
60.8  
124.2 124.2 119.4 103.8 88.2  
72.6  
66.0  
94.3  
76.4  
58.6  
79.9  
-
-
-
-
88.2  
70.9  
53.7  
75.3  
-
-
115.6 97.7  
62.0  
-
-
109.8 92.5  
58.0  
79.6  
-
-
-
136.9 119.1 101.2 83.3  
65.5  
131.4 114.1 96.9  
62.3  
80.8  
134.3 134.3 120.1 102.2 84.4  
128.2 128.2 129.1 111.3 93.4  
66.5  
75.5  
-
124.1 124.1 115.3 98.0  
63.5  
69.2  
-
119.9 119.9 121.0 103.7 86.4  
124.0 104.8 85.6  
66.4  
-
117.7 99.1  
80.5  
61.8  
-
144.9 127.7 108.5 89.2  
70.0  
-
136.4 122.2 103.5 84.9  
66.3  
-
4500  
5000  
137.1 137.1 130.0 110.8 91.5  
130.9 130.9 131.3 112.1 92.9  
72.3  
73.7  
-
126.3 126.3 122.0 103.3 84.7  
122.1 122.1 122.6 104.0 85.4  
66.0  
66.7  
-
132.5 111.9 91.3  
70.7  
-
125.7 105.7 85.7  
65.6  
-
153.0 136.3 115.7 95.1  
74.5  
-
141.4 130.2 110.2 90.2  
70.2  
-
139.9 139.9 139.9 119.3 98.7  
133.5 133.5 133.5 113.0 92.4  
95°F  
78.1  
71.8  
128.6 128.6 128.6 108.6 88.6  
124.3 124.3 124.3 104.3 84.3  
105°F  
68.6  
64.2  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
142.4  
128.6  
114.8  
103.8  
147.0  
132.8  
118.6  
107.1  
105.0  
151.6  
137.0  
122.3  
110.5  
108.3  
156.2  
141.1  
126.0  
113.9  
111.6  
143.3  
127.9  
115.6  
113.3  
145.5  
129.9  
117.4  
115.1  
9.2  
9.1  
9.0  
8.8  
9.2  
9.1  
9.0  
8.9  
8.9  
9.3  
9.2  
9.1  
8.9  
8.9  
9.3  
9.2  
9.1  
8.9  
8.9  
9.2  
9.1  
9.0  
9.0  
9.2  
9.1  
9.0  
9.0  
58.1  
74.5  
90.9  
47.3  
63.7  
80.2  
36.6  
53.0  
69.4  
-
-
-
129.8  
117.4  
104.9  
94.6  
10.2  
9.9  
56.2  
74.6  
93.0  
94.6  
65.1  
82.5  
45.6  
63.8  
82.1  
92.9  
50.3  
69.8  
34.9  
53.1  
71.4  
82.3  
37.6  
57.1  
76.7  
89.9  
91.0  
40.3  
61.2  
82.0  
97.4  
-
-
-
42.3  
58.7  
72.3  
-
-
-
42.4  
60.6  
71.6  
-
-
-
2500  
3000  
48.0  
61.5  
-
-
9.7  
49.9  
60.8  
-
-
103.8 100.4 83.0  
50.8  
9.5  
50.1  
66.1  
84.3  
53.4  
71.6  
40.7  
58.9  
77.1  
-
133.5  
120.8  
108.0  
97.3  
10.2  
10.0  
9.8  
-
46.2  
64.4  
79.5  
81.4  
-
-
-
44.5  
64.0  
77.2  
78.3  
-
-
-
102.5 89.8  
51.7  
66.7  
68.7  
-
-
100.0 89.4  
51.3  
64.5  
65.6  
-
-
107.1 104.9 92.2  
105.0 105.0 94.1  
54.0  
9.5  
97.3  
97.9  
74.0  
90.5  
96.2  
97.9  
54.9  
75.8  
51.8  
56.0  
97.9  
9.6  
52.9  
74.1  
94.2  
59.4  
79.5  
44.7  
64.8  
84.8  
-
137.3  
124.1  
111.0  
100.1  
100.6  
141.0  
127.5  
114.0  
102.8  
103.4  
129.6  
115.9  
104.5  
105.1  
131.7  
117.7  
106.2  
106.8  
10.3  
10.1  
9.8  
-
50.1  
70.1  
-
-
46.5  
67.4  
82.8  
82.7  
-
-
-
3500  
4000  
114.2 99.5  
55.4  
72.0  
74.1  
-
-
106.9 96.7  
100.1 99.5  
52.7  
68.1  
68.1  
-
-
110.5 109.4 101.4 86.7  
108.3 108.3 103.5 88.8  
57.3  
9.6  
53.5  
59.4  
9.7  
100.6 100.6 97.4  
53.4  
82.1  
65.4  
48.8  
70.6  
-
-
10.4  
10.1  
9.9  
82.9  
98.4  
59.6  
81.8  
43.0  
65.2  
-
104.0 87.3  
54.0  
75.8  
-
-
-
48.6  
70.8  
-
-
-
125.9 109.2 92.5  
59.1  
77.2  
79.5  
-
113.9 104.0 87.4  
54.2  
71.8  
70.6  
-
113.9 113.9 110.5 93.9  
111.6 111.6 112.9 96.2  
60.5  
62.8  
-
9.7  
102.8 102.8 105.0 88.4  
103.4 103.4 103.8 87.2  
55.2  
54.0  
-
9.7  
111.4 93.4  
75.3  
57.2  
80.6  
10.2  
9.9  
105.3 87.4  
69.5  
51.5  
75.2  
127.9 116.7 98.6  
62.5  
77.8  
77.8  
-
-
115.8 109.5 93.1  
57.2  
69.7  
69.4  
-
-
4500  
5000  
115.6 115.6 114.0 95.9  
113.3 113.3 114.0 95.9  
59.7  
59.7  
-
9.7  
104.5 104.5 105.6 87.6  
105.1 105.1 105.3 87.4  
51.8  
51.5  
-
9.7  
118.9 99.4  
80.0  
60.5  
10.2  
9.9  
112.2 93.0  
73.7  
54.5  
79.5  
129.9 124.2 104.8 85.3  
117.4 117.4 117.4 97.9  
115.1 115.1 115.1 95.6  
65.8  
78.4  
76.1  
-
117.7 114.9 98.8  
60.3  
67.6  
68.3  
-
59.0  
56.7  
9.7  
106.2 106.2 106.2 86.9  
106.8 106.8 106.8 87.5  
48.4  
49.0  
9.8  
Johnson Controls Unitary Products  
23  
528194-YTG-F-1210  
ZF120 (10 Ton) (Continued)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
1
WB  
(°F)  
CFM  
2500  
2
2
90  
85  
115°F  
43.9  
63.9  
84.0  
85.5  
47.2  
68.1  
88.9  
87.5  
90.8  
50.5  
72.2  
93.9  
89.6  
93.0  
53.8  
76.3  
80  
75  
70  
65  
90  
85  
125°F  
42.9  
64.0  
85.2  
76.3  
45.8  
66.3  
86.8  
77.7  
83.7  
48.7  
68.6  
88.4  
79.2  
85.3  
51.6  
70.8  
90.0  
80.6  
86.9  
75.4  
91.7  
82.2  
88.5  
80.0  
93.5  
83.7  
90.2  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
117.2  
106.1  
95.0  
11.2  
10.8  
10.4  
10.1  
11.2  
10.9  
10.5  
10.2  
10.3  
11.3  
10.9  
10.6  
10.3  
10.4  
11.4  
11.0  
10.6  
10.4  
10.5  
11.1  
10.7  
10.4  
10.5  
11.1  
10.7  
10.5  
10.6  
54.3  
74.7  
95.0  
85.5  
64.1  
80.7  
97.4  
87.5  
90.8  
73.9  
86.8  
99.7  
89.6  
93.0  
83.7  
92.9  
33.2  
53.2  
73.3  
81.6  
34.5  
55.4  
76.3  
87.5  
87.8  
35.9  
57.6  
79.3  
93.5  
91.3  
37.2  
59.8  
82.3  
99.5  
94.7  
63.6  
-
-
-
104.6  
94.9  
85.2  
76.3  
106.6  
96.7  
86.8  
77.7  
83.7  
108.6  
98.5  
88.4  
79.2  
85.3  
110.6  
100.3  
90.0  
80.6  
86.9  
102.2  
91.7  
82.2  
88.5  
104.2  
93.5  
83.7  
90.2  
12.1  
11.6  
11.1  
10.8  
12.3  
11.7  
11.2  
10.9  
11.0  
12.4  
11.8  
11.3  
11.0  
11.1  
12.5  
11.9  
11.4  
11.1  
11.2  
12.0  
11.5  
11.1  
11.3  
12.1  
11.5  
11.2  
11.3  
64.4  
74.8  
85.2  
76.3  
71.1  
78.9  
86.8  
77.7  
83.7  
77.9  
83.1  
88.4  
79.2  
85.3  
84.6  
87.3  
90.0  
80.6  
86.9  
93.1  
91.7  
82.2  
88.5  
98.9  
93.5  
83.7  
90.2  
31.5  
53.3  
75.2  
76.3  
31.5  
53.7  
75.9  
77.7  
83.7  
31.5  
54.0  
76.5  
79.2  
85.2  
31.5  
54.3  
77.2  
80.6  
85.7  
57.7  
82.0  
82.2  
87.9  
61.2  
86.9  
83.7  
90.2  
-
-
-
42.5  
62.6  
70.9  
-
-
-
42.6  
64.5  
70.2  
-
-
-
51.8  
60.1  
-
-
53.8  
59.4  
-
-
85.5  
49.4  
48.7  
120.1  
108.7  
97.4  
-
-
42.7  
63.6  
74.9  
75.2  
-
-
-
41.0  
63.2  
72.6  
72.1  
-
-
-
3000  
3500  
4000  
51.0  
62.2  
62.5  
-
-
50.6  
60.0  
59.4  
-
-
87.5  
49.6  
47.3  
90.8  
49.8  
46.8  
122.9  
111.3  
99.7  
-
-
43.0  
64.7  
78.9  
76.7  
-
-
-
39.4  
62.0  
75.0  
70.6  
-
-
-
50.1  
64.3  
62.1  
-
-
47.4  
60.5  
56.1  
-
-
89.6  
49.7  
45.9  
93.0  
47.5  
41.5  
125.8  
113.9  
102.0  
91.7  
-
-
43.2  
65.7  
82.9  
78.2  
45.8  
69.8  
79.4  
78.8  
48.4  
73.8  
75.9  
79.4  
-
-
-
37.8  
60.7  
77.4  
69.2  
40.1  
64.4  
71.2  
70.3  
42.3  
68.0  
64.9  
71.4  
-
-
-
102.0 98.8  
49.2  
66.4  
61.6  
-
44.2  
61.0  
52.7  
-
91.7  
95.1  
99.2  
91.7  
95.1  
81.4  
49.8  
45.1  
-
44.5  
36.2  
-
95.1  
115.9  
103.8  
93.3  
103.8 102.2 87.6  
52.0  
61.6  
61.0  
-
-
46.7  
53.5  
52.6  
-
-
4500  
5000  
93.3  
96.8  
93.3  
96.8  
97.2  
96.6  
67.4  
43.8  
43.2  
-
35.8  
34.9  
-
96.8  
117.9  
105.6  
95.0  
105.5 86.5  
105.6 105.6 92.8  
54.7  
56.8  
60.4  
-
49.2  
46.0  
52.5  
-
95.0  
98.5  
95.0  
98.5  
95.0  
98.5  
37.8  
41.3  
27.2  
33.7  
98.5  
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower  
Performance Table for the kW of the supply air blower motor.  
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.  
24  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
ZF150 (12.5 Ton)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
WB  
(°F)  
CFM  
3125  
2
90  
85  
75°F  
62.8  
86.4  
80  
75  
70  
65  
90  
85  
85°F  
60.7  
83.5  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
192.8  
179.7  
166.6  
150.6  
200.7  
187.1  
173.4  
156.8  
152.3  
208.7  
194.5  
180.2  
163.0  
158.3  
216.6  
201.8  
187.1  
169.2  
164.3  
203.6  
188.7  
170.7  
165.7  
205.4  
190.4  
172.2  
167.2  
10.1  
9.8  
9.6  
9.5  
10.1  
9.9  
9.6  
9.5  
9.5  
10.1  
9.9  
9.7  
9.6  
9.5  
10.1  
9.9  
9.7  
9.6  
9.6  
9.9  
9.7  
9.6  
9.6  
10.0  
9.8  
9.7  
9.7  
75.6  
99.3  
49.9  
73.5  
-
-
-
-
185.3  
171.3  
157.2  
142.2  
192.2  
177.6  
163.0  
147.5  
144.4  
199.1  
184.0  
168.9  
152.8  
149.5  
206.0  
190.3  
174.7  
158.1  
154.7  
193.2  
177.3  
160.4  
157.0  
196.0  
179.9  
162.8  
159.3  
11.1  
10.9  
10.7  
10.6  
11.1  
10.9  
10.8  
10.6  
10.6  
11.2  
11.0  
10.8  
10.7  
10.6  
11.2  
11.0  
10.8  
10.7  
10.7  
11.1  
10.9  
10.8  
10.7  
11.1  
10.9  
10.8  
10.8  
73.4  
96.2  
48.0  
70.8  
-
-
-
-
60.6  
84.3  
-
58.1  
80.9  
-
122.9 110.0 97.1  
71.4  
-
119.1 106.4 93.6  
68.2  
-
150.6 133.0 119.1 106.2 93.3  
80.4  
142.2 132.0 115.5 102.8 90.1  
77.4  
83.8  
69.2  
54.6  
80.5  
-
-
-
-
-
-
81.3  
66.8  
52.4  
77.4  
-
-
-
-
109.7 95.1  
66.0  
106.2 91.8  
63.0  
-
-
3750  
4375  
5000  
135.6 121.0 106.5 91.9  
77.3  
131.2 116.8 102.4 88.0  
73.5  
156.8 145.1 130.5 115.9 101.3 86.7  
152.3 152.3 138.3 123.7 109.1 94.5  
147.5 140.7 126.3 111.9 97.4  
83.0  
144.4 144.4 132.5 118.1 103.7 89.3  
92.0  
75.7  
59.4  
-
-
-
-
-
-
89.2  
73.0  
56.9  
-
-
-
-
-
-
120.2 103.9 87.6  
71.3  
116.3 100.1 84.0  
67.9  
148.3 132.1 115.8 99.5  
83.2  
143.4 127.2 111.1 95.0  
78.8  
163.0 157.1 141.9 125.6 109.3 93.0  
158.3 158.3 150.4 134.1 117.8 101.5  
152.8 149.4 137.0 120.9 104.8 88.6  
149.5 149.5 143.9 127.7 111.6 95.4  
100.2 82.2  
64.2  
-
-
-
-
-
-
97.1  
79.2  
61.4  
-
-
-
-
-
-
130.6 112.6 94.6  
76.7  
126.3 108.5 90.6  
72.8  
161.1 143.1 125.1 107.1 89.1  
155.5 137.7 119.8 102.0 84.1  
169.2 169.2 153.3 135.3 117.3 99.3  
164.3 164.3 162.5 144.5 126.5 108.5  
158.1 158.1 147.8 130.0 112.1 94.3  
154.7 154.7 155.2 137.3 119.5 101.6  
138.4 119.4 100.5 81.5  
-
-
-
134.4 115.4 96.4  
77.5  
-
-
-
171.4 151.7 132.8 113.8 94.8  
165.5 146.5 127.6 108.6 89.6  
5625  
6250  
170.7 170.7 162.7 143.8 124.8 105.8  
165.7 165.7 164.8 145.8 126.9 107.9  
160.4 160.4 155.3 136.3 117.3 98.3  
157.0 157.0 157.2 138.2 119.2 100.3  
146.2 126.2 106.3 86.3  
-
-
-
142.5 122.4 102.3 82.1  
-
-
-
181.6 160.4 140.4 120.5 100.5  
175.5 155.4 135.3 115.1 95.0  
172.2 172.2 172.2 152.2 132.2 112.3  
167.2 167.2 167.2 147.2 127.2 107.3  
95°F  
162.8 162.8 162.8 142.7 122.5 102.4  
159.3 159.3 159.3 139.2 119.0 98.9  
105°F  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
177.9  
162.8  
147.8  
133.8  
183.7  
168.2  
152.6  
138.2  
136.4  
189.6  
173.5  
157.5  
142.6  
140.7  
195.4  
178.9  
162.3  
147.0  
145.1  
182.7  
165.9  
150.2  
148.2  
186.6  
169.4  
153.4  
151.4  
12.1  
12.0  
11.8  
11.7  
12.2  
12.0  
11.9  
11.7  
11.7  
12.2  
12.1  
11.9  
11.8  
11.8  
12.3  
12.1  
12.0  
11.8  
11.8  
12.2  
12.0  
11.9  
11.8  
12.2  
12.0  
11.9  
11.9  
71.1  
93.2  
58.6  
80.6  
46.0  
68.1  
-
-
-
165.4  
151.1  
136.8  
125.4  
170.9  
156.1  
141.4  
129.6  
127.8  
176.4  
161.2  
145.9  
133.8  
131.9  
181.9  
166.2  
150.5  
138.0  
136.0  
169.5  
153.5  
140.7  
138.7  
172.8  
156.5  
143.4  
141.4  
13.5  
13.4  
13.3  
13.1  
13.5  
13.4  
13.3  
13.1  
13.1  
13.6  
13.5  
13.3  
13.2  
13.2  
13.6  
13.5  
13.4  
13.2  
13.2  
13.5  
13.4  
13.2  
13.2  
13.5  
13.4  
13.2  
13.2  
65.9  
88.4  
53.7  
75.9  
41.2  
63.4  
85.7  
-
-
-
55.6  
77.6  
-
-
51.0  
73.2  
-
-
3125  
3750  
115.2 102.7 90.1  
65.1  
86.9  
-
-
111.0 98.2  
60.7  
81.1  
-
-
133.8 131.0 111.9 99.4  
74.3  
125.4 124.0 106.1 93.6  
68.6  
78.7  
64.5  
50.2  
74.3  
-
-
73.4  
97.7  
59.2  
83.6  
45.1  
69.4  
-
-
102.8 88.5  
60.0  
84.0  
-
-
55.3  
79.6  
-
-
126.8 112.6 98.3  
69.8  
-
122.1 107.9 93.8  
65.5  
-
138.2 136.3 122.1 107.8 93.5  
136.4 136.4 126.8 112.5 98.3  
79.3  
129.6 128.7 116.1 102.0 87.8  
127.8 127.8 118.7 104.6 90.4  
73.7  
84.0  
76.3  
86.3  
70.3  
54.4  
80.4  
-
-
-
-
-
-
80.9  
64.8  
49.0  
75.4  
-
-
-
-
112.4 96.4  
64.4  
107.0 91.2  
59.6  
-
4375  
5000  
138.4 122.4 106.5 90.5  
74.5  
133.2 117.7 101.9 86.1  
70.3  
-
142.6 141.7 132.2 116.2 100.2 84.2  
140.7 140.7 137.3 121.3 105.4 89.4  
133.8 133.3 126.2 110.4 94.6  
131.9 131.9 129.0 113.2 97.4  
78.8  
81.6  
93.9  
76.2  
58.5  
-
-
-
-
-
-
88.4  
70.3  
52.9  
81.4  
-
-
-
-
-
-
122.0 104.3 86.6  
68.9  
116.3 98.9  
64.0  
150.0 132.3 114.6 96.9  
79.2  
144.3 127.5 110.0 92.5  
75.1  
147.0 147.0 142.3 124.6 106.9 89.2  
145.1 145.1 147.8 130.1 112.4 94.7  
138.0 138.0 136.2 118.7 101.3 83.8  
136.0 136.0 139.2 121.8 104.3 86.9  
130.4 111.4 92.4  
73.4  
-
-
-
124.3 105.6 86.9  
68.2  
-
-
-
159.7 141.3 122.3 103.4 84.4  
150.4 136.1 117.4 98.7  
80.0  
5625  
6250  
150.2 150.2 147.9 128.9 109.9 90.9  
148.2 148.2 149.6 130.6 111.6 92.6  
140.7 140.7 139.8 121.1 102.4 83.7  
138.7 138.7 140.3 121.6 102.9 84.2  
138.8 118.5 98.3  
78.0  
-
-
-
132.3 112.4 92.4  
72.5  
-
-
-
169.4 150.4 130.1 109.8 89.5  
156.5 144.8 124.8 104.9 84.9  
153.4 153.4 153.4 133.1 112.8 92.5  
151.4 151.4 151.4 131.1 110.8 90.5  
143.4 143.4 143.4 123.5 103.5 83.6  
141.4 141.4 141.4 121.4 101.5 81.5  
Johnson Controls Unitary Products  
25  
528194-YTG-F-1210  
ZF150 (12.5 Ton) (Continued)  
Temperature of Air on Condenser Coil  
Air on  
Evaporator Coil  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Sensible Capacity (MBh)  
Return Dry Bulb (°F)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
Total  
Capacity  
(MBh)  
Total  
Input  
(kW)  
1
1
WB  
(°F)  
CFM  
3125  
2
2
90  
85  
115°F  
48.8  
80  
75  
70  
65  
90  
85  
125°F  
44.0  
80  
75  
70  
65  
77  
72  
67  
62  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
77  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
152.8  
139.4  
125.9  
117.0  
158.0  
144.1  
130.1  
121.0  
119.1  
163.2  
148.8  
134.4  
125.0  
123.0  
168.3  
153.5  
138.7  
128.9  
126.9  
156.2  
141.1  
131.2  
129.2  
158.9  
143.6  
133.5  
131.4  
14.9  
14.8  
14.7  
14.5  
14.9  
14.8  
14.7  
14.5  
14.6  
14.9  
14.8  
14.7  
14.6  
14.6  
15.0  
14.9  
14.8  
14.6  
14.6  
14.9  
14.8  
14.6  
14.6  
14.9  
14.8  
14.6  
14.6  
60.7  
83.7  
36.4  
58.8  
81.2  
-
-
-
-
140.3  
127.6  
114.9  
108.6  
145.1  
132.0  
118.9  
112.4  
110.5  
150.0  
136.4  
122.9  
116.1  
114.2  
154.8  
140.8  
126.8  
119.9  
117.9  
143.0  
128.7  
121.7  
119.6  
145.1  
130.6  
123.5  
121.4  
16.2  
16.2  
16.1  
15.9  
16.3  
16.2  
16.1  
15.9  
16.0  
16.3  
16.2  
16.1  
15.9  
16.0  
16.3  
16.3  
16.2  
16.0  
16.0  
16.2  
16.2  
16.0  
16.0  
16.2  
16.2  
16.0  
16.0  
52.4  
79.0  
31.5  
54.2  
76.8  
-
-
-
-
71.3  
46.3  
68.8  
-
66.6  
41.7  
64.4  
82.0  
-
-
106.7 93.7  
56.3  
75.4  
-
-
102.4 89.2  
51.9  
69.6  
-
-
117.0 117.0 100.3 87.8  
62.9  
108.6 108.6 94.4  
57.2  
68.1  
92.7  
54.0  
78.7  
40.0  
64.6  
-
-
62.7  
87.7  
48.8  
73.8  
34.9  
59.8  
84.8  
-
50.6  
75.2  
-
-
45.9  
70.8  
-
-
3750  
4375  
5000  
117.4 103.3 89.3  
61.2  
82.1  
82.6  
-
-
112.6 98.7  
56.9  
76.4  
74.7  
-
-
121.0 121.0 110.2 96.2  
119.1 119.1 110.7 96.6  
68.1  
112.4 112.4 104.3 90.3  
110.5 110.5 102.6 88.6  
62.5  
68.5  
60.8  
75.4  
59.2  
43.6  
70.5  
-
-
73.0  
96.4  
53.7  
80.9  
38.2  
65.5  
-
-
101.7 86.1  
54.8  
81.7  
-
-
50.0  
77.3  
-
-
128.0 113.0 97.3  
66.1  
-
122.8 108.2 92.8  
61.9  
83.2  
81.4  
-
-
125.0 125.0 120.1 104.5 88.9  
123.0 123.0 120.6 105.0 89.4  
73.3  
116.1 116.1 114.1 98.7  
114.2 114.2 112.3 96.8  
67.8  
73.8  
66.0  
82.8  
64.4  
47.2  
76.3  
-
-
-
-
83.3  
58.5  
41.5  
71.2  
-
-
110.7 93.5  
59.1  
-
-
105.1 88.1  
54.2  
-
-
-
138.7 122.6 105.4 88.2  
71.0  
126.8 117.7 100.8 83.8  
66.8  
128.9 128.9 130.1 112.9 95.7  
126.9 126.9 130.6 113.4 96.2  
78.4  
79.0  
-
119.9 119.9 119.9 107.0 90.0  
117.9 117.9 117.9 105.0 88.1  
73.1  
71.1  
-
118.3 99.9  
81.4  
63.0  
-
112.2 94.1  
75.9  
57.8  
-
141.1 130.9 112.5 94.1  
75.6  
-
128.7 125.7 107.6 89.4  
71.3  
-
5625  
6250  
131.2 131.2 131.8 113.3 94.9  
129.2 129.2 131.0 112.6 94.2  
76.5  
75.7  
-
121.7 121.7 121.7 105.6 87.5  
119.6 119.6 119.6 103.6 85.4  
69.3  
67.3  
-
125.8 106.2 86.6  
66.9  
-
119.4 100.0 80.7  
61.4  
-
143.6 139.2 119.6 99.9  
80.3  
-
130.6 130.6 114.3 95.0  
75.7  
-
133.5 133.5 133.5 113.8 94.2  
131.4 131.4 131.4 111.8 92.1  
74.6  
72.5  
123.5 123.5 123.5 104.2 84.9  
121.4 121.4 121.4 102.1 82.8  
65.6  
63.5  
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower  
Performance Table for the kW of the supply air blower motor.  
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.  
26  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
Airflow Performance  
ZF078-150 Side Duct Application  
ZF078 (6.5 Ton) Side Duct  
Air Flow  
Available External Static Pressure - IWG1  
0.8 1.0 1.2 1.4  
0.2  
0.4  
0.6  
1.6  
1.8  
2.0  
(CFM)  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 1.5 HP & Drive  
Hi Static 2 HP & Drive  
1800  
2000  
2200  
2400  
2600  
2800  
3000  
3200  
3400  
751  
776  
804  
835  
869  
906  
945  
987  
0.22  
0.35  
0.50  
0.66  
0.84  
1.03  
813  
838  
866  
897  
931  
968  
0.43  
0.56  
0.71  
0.87  
1.05  
872  
897  
925  
956  
990  
0.62  
0.75  
0.90  
929  
954  
982  
0.78  
985 0.93 1040 1.07 1095 1.20 1150 1.33 1206 1.46 1265 1.59  
0.92 1010 1.07 1064 1.20 1119 1.33 1175 1.46 1231 1.59 1289 1.72  
1.06 1038 1.21 1092 1.35 1147 1.48 1203 1.61 1259 1.73 1317 1.87  
1.06 1013 1.22 1069 1.37 1124 1.51 1178 1.64 1234 1.77 1290 1.90 1348 2.03  
1.24 1047 1.40 1103 1.55 1158 1.69 1212 1.82 1268 1.95 1324 2.07 1382 2.21  
1.25 1027 1.43 1084 1.60 1139 1.75 1194 1.89 1249 2.02 1304 2.14 1361 2.27  
-
-
-
-
-
-
-
-
1.25 1007 1.46 1066 1.65 1123 1.81 1179 1.96 1234 2.10 1288 2.23  
-
-
-
-
-
-
-
-
-
-
-
-
1.48 1048 1.69 1107 1.88 1165 2.04 1220 2.19  
-
-
-
-
-
-
-
-
1030 1.73 1092 1.94 1151 2.12 1208 2.29  
-
-
2 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF090 (7.5 Ton) Side Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 1.5 HP & Drive  
Hi Static 3 HP & Drive  
2000  
2200  
2400  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
776  
804  
835  
869  
906  
945  
987  
0.35  
0.50  
0.66  
0.84  
1.03  
838  
866  
897  
931  
968  
0.56  
0.71  
0.87  
1.05  
897  
925  
956  
990  
0.75  
0.90  
954  
982  
0.92 1010 1.07 1064 1.20 1119 1.33 1175 1.46 1231 1.59 1289 1.72  
1.06 1038 1.21 1092 1.35 1147 1.48 1203 1.61 1259 1.73 1317 1.87  
1.06 1013 1.22 1069 1.37 1124 1.51 1178 1.64 1234 1.77 1290 1.90 1348 2.03  
1.24 1047 1.40 1103 1.55 1158 1.69 1212 1.82 1268 1.95 1324 2.07 1382 2.21  
1.25 1027 1.43 1084 1.60 1139 1.75 1194 1.89 1249 2.02 1304 2.14 1361 2.27 1419 2.40  
1.25 1007 1.46 1066 1.65 1123 1.81 1179 1.96 1234 2.10 1288 2.23 1344 2.36 1400 2.48 1458 2.62  
1.48 1048 1.69 1107 1.88 1165 2.04 1220 2.19 1275 2.33 1330 2.46 1385 2.59 1442 2.71 1500 2.85  
1030 1.73 1092 1.94 1151 2.12 1208 2.29 1264 2.44 1319 2.58 1374 2.71 1429 2.84 1485 2.96 1544 3.10  
1076 1.99 1138 2.20 1197 2.39 1254 2.56 1310 2.71 1364 2.84 1419 2.97 1475 3.10 1531 3.23 1589 3.36  
1124 2.27 1185 2.48 1245 2.67 1302 2.84 1357 2.99 1412 3.12 1467 3.25 1522 3.38  
-
-
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF102 (8.5 Ton) Side Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 2 HP & Drive  
Hi Static 3 HP & Drive  
980 1.80 1025 2.05 1068 2.35  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
4000  
4200  
628  
648  
666  
684  
702  
721  
742  
765  
789  
0.56  
0.67  
0.80  
0.95  
1.11  
1.28  
1.47  
1.67  
1.87  
678  
698  
717  
735  
753  
772  
793  
815  
840  
0.76  
0.87  
1.00  
1.15  
1.31  
1.48  
1.67  
1.86  
2.07  
730  
750  
768  
786  
804  
824  
844  
867  
891  
0.93  
1.04  
1.17  
1.32  
1.48  
1.65  
1.84  
2.04  
2.24  
781  
801  
820  
838  
856  
875  
896  
918  
943  
1.09  
1.20  
1.33  
1.48  
1.64  
1.81  
2.00  
2.19  
2.40  
833  
853  
871  
889  
907  
927  
947  
970  
995  
1.25  
1.36  
1.49  
1.63  
1.79  
1.97  
2.15  
883  
903  
922  
940  
958  
977  
998  
1.41  
1.52  
1.65  
1.80  
933  
953  
971  
989  
1.59  
1.70 1000 1.91 1046 2.16 1088 2.46  
1.83 1019 2.04 1064 2.29 1106 2.59  
1.98 1037 2.19 1082 2.44 1124 2.74  
1.96 1007 2.14 1055 2.35 1100 2.60 1142 2.90  
2.13 1027 2.31 1074 2.52 1119 2.77  
2.32 1047 2.50 1095 2.71 1140 2.96  
-
-
-
-
-
-
-
-
2.35 1020 2.51 1070 2.70 1117 2.91  
2.56 1045 2.72 1094 2.90  
-
-
-
-
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
Johnson Controls Unitary Products  
27  
 
528194-YTG-F-1210  
ZF120 (10 Ton) Side Duct  
Air Flow  
Available External Static Pressure - IWG1  
0.8 1.0 1.2 1.4  
0.2  
0.4  
0.6  
1.6  
1.8  
2.0  
(CFM)  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 2 HP & Drive  
Hi Static 3 HP & Drive  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
4000  
4200  
4400  
4600  
4800  
5000  
675  
686  
699  
713  
728  
745  
763  
783  
805  
828  
852  
879  
906  
0.53  
0.63  
0.75  
0.88  
1.02  
1.18  
1.36  
1.55  
1.77  
2.00  
2.25  
2.52  
2.81  
726  
738  
750  
764  
779  
796  
815  
835  
856  
879  
904  
930  
958  
0.74  
0.84  
0.96  
1.09  
1.23  
1.39  
1.57  
1.76  
1.98  
2.21  
2.46  
2.73  
776  
787  
800  
814  
829  
846  
864  
884  
906  
929  
953  
980  
0.94  
1.04  
1.16  
1.28  
1.43  
1.59  
1.76  
1.96  
2.17  
2.41  
824  
835  
847  
861  
877  
893  
912  
932  
953  
976  
1.12  
1.23  
1.34  
1.47  
1.61  
1.77  
1.95  
2.15  
2.36  
870  
881  
893  
907  
923  
939  
958  
978  
999  
1.30  
1.41  
1.52  
1.65  
1.79  
1.95  
914  
925  
938  
952  
967  
984  
1.48  
1.58  
1.70  
1.83  
957  
969  
981  
995  
1.65 1000 1.82 1041 1.99 1082 2.17  
1.76 1011 1.93 1052 2.10 1093 2.27  
1.87 1024 2.04 1065 2.21 1106 2.39  
2.00 1037 2.17 1079 2.34 1119 2.52  
1.97 1010 2.14 1053 2.31 1094 2.48 1135 2.66  
2.13 1027 2.30 1069 2.47 1111 2.64 1152 2.82  
2.13 1002 2.31 1046 2.48 1088 2.65 1129 2.82 1170 3.00  
2.33 1022 2.50 1066 2.67 1108 2.84 1149 3.02 1190 3.19  
2.54 1044 2.72 1087 2.89 1129 3.06 1171 3.23 1211 3.41  
2.59 1022 2.77 1067 2.95 1110 3.12 1152 3.29  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2.66 1001 2.85 1047 3.03 1092 3.20 1135 3.37  
-
-
-
-
-
-
2.93 1027 3.12 1073 3.30  
-
-
-
-
-
-
-
-
3.02 1007 3.22 1055 3.41  
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF150 (12.5 Ton) Side Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
3 HP & Field Supplied Drive  
Standard 3 HP & Drive  
3200  
3400  
3600  
3800  
4000  
4200  
4400  
4600  
4800  
5000  
5200  
5400  
5600  
5800  
6000  
6200  
684  
709  
734  
761  
789  
818  
847  
877  
907  
937  
967  
997  
1.00  
1.15  
1.30  
1.48  
1.66  
1.87  
2.09  
2.33  
2.59  
2.86  
741  
765  
791  
818  
846  
875  
904  
934  
963  
993  
1.16  
1.30  
1.46  
1.63  
1.82  
2.03  
2.25  
2.49  
794  
818  
844  
871  
899  
928  
957  
986  
1.32  
1.46  
1.62  
1.79  
1.98  
2.19  
844  
868  
894  
921  
949  
978  
1.48  
1.62  
1.78  
1.95  
2.14  
892  
916  
942  
969  
997  
1.65  
1.79  
1.94  
940  
964  
990  
1.81  
988  
1.97 1036 2.12 1087 2.27 1141 2.42  
1.95 1012 2.11 1061 2.26 1112 2.42 1166 2.56  
2.10 1038 2.26 1087 2.42 1137 2.57 1191 2.72  
2.12 1017 2.28 1065 2.44 1114 2.59 1164 2.75 1218 2.89  
2.31 1045 2.47 1093 2.63 1142 2.78 1192 2.93 1246 3.08  
2.35 1026 2.51 1074 2.67 1121 2.83 1170 2.99 1221 3.14 1275 3.29  
2.41 1007 2.57 1055 2.73 1103 2.90 1151 3.06 1199 3.21 1250 3.36 1304 3.51  
2.65 1036 2.81 1085 2.97 1132 3.14 1180 3.29 1229 3.45 1280 3.60 1334 3.75  
2.75 1016 2.91 1066 3.07 1115 3.23 1162 3.39 1210 3.55 1259 3.71 1310 3.86 1364 4.01  
3.02 1046 3.18 1096 3.34 1145 3.50 1192 3.66 1240 3.82 1289 3.98 1340 4.13 1394 4.28  
3.15 1023 3.31 1076 3.47 1126 3.63 1175 3.79 1222 3.95 1270 4.11 1319 4.27 1370 4.42 1424 4.57  
3.45 1053 3.61 1106 3.77 1156 3.93 1205 4.09 1252 4.26 1300 4.41 1349 4.57 1400 4.72 1454 4.87  
1027 3.77 1083 3.93 1136 4.09 1186 4.25 1235 4.41 1282 4.57 1330 4.73 1379 4.89 1430 5.04 1484 5.19  
1057 4.11 1113 4.26 1166 4.42 1216 4.59 1264 4.75 1312 4.91 1360 5.07 1409 5.22  
-
-
-
-
-
-
-
-
-
-
-
-
1086 4.46 1143 4.61 1196 4.77 1246 4.93 1294 5.10 1342 5.26  
-
-
-
-
-
-
-
-
1116 4.82 1172 4.98 1225 5.14 1275 5.30  
Hi Static 5 HP & Drive  
-
-
-
-
5 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
28  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Bottom Duct Application  
ZF078 (6.5 Ton) Bottom Duct  
Air Flow  
Available External Static Pressure - IWG1  
0.8 1.0 1.2 1.4  
0.2  
0.4  
0.6  
1.6  
1.8  
2.0  
(CFM)  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 1.5 HP & Drive  
Hi Static 2 HP & Drive  
1800  
2000  
2200  
2400  
2600  
2800  
3000  
3200  
3400  
775  
803  
838  
878  
923  
971  
0.31  
0.45  
0.60  
0.78  
0.98  
850  
878  
913  
953  
997  
0.53  
0.67  
0.82  
924  
952  
986  
0.72 998 0.89 1072 1.05 1147 1.20 1224 1.35 1303 1.51 1384 1.69 1469 1.89  
0.86 1026 1.03 1100 1.19 1175 1.34 1252 1.49 1331 1.65 1412 1.83 1497 2.03  
1.01 1060 1.19 1134 1.34 1210 1.49 1286 1.65 1365 1.81 1447 1.98 1532 2.18  
1.00 1027 1.19 1100 1.36 1174 1.52 1250 1.67 1327 1.82 1405 1.98 1487 2.16  
-
-
-
-
-
-
-
-
-
-
-
-
1.20 1071 1.39 1145 1.56 1219 1.72 1294 1.87 1371 2.02 1450 2.18  
-
-
-
-
-
-
-
-
-
-
1.20 1046 1.42 1119 1.61 1193 1.78 1267 1.94 1343 2.09 1419 2.24  
-
-
-
-
-
-
-
-
1023 1.44 1097 1.66 1171 1.85 1245 2.03 1319 2.18  
-
-
-
-
-
-
-
-
-
-
-
-
1077 1.71 1151 1.93 1225 2.12 1299 2.29  
1133 1.99 1208 2.21  
-
-
-
-
-
-
-
-
2 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF090 (7.5 Ton) Bottom Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 1.5 HP & Drive  
Hi Static 3 HP & Drive  
2000  
2200  
2400  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
803  
838  
878  
923  
971  
0.45  
0.60  
0.78  
0.98  
878  
913  
953  
997  
0.67  
0.82  
952  
986  
0.86 1026 1.03 1100 1.19 1175 1.34 1252 1.49 1331 1.65 1412 1.83 1497 2.03  
1.01 1060 1.19 1134 1.34 1210 1.49 1286 1.65 1365 1.81 1447 1.98 1532 2.18  
1.00 1027 1.19 1100 1.36 1174 1.52 1250 1.67 1327 1.82 1405 1.98 1487 2.16 1572 2.36  
1.20 1071 1.39 1145 1.56 1219 1.72 1294 1.87 1371 2.02 1450 2.18 1532 2.36 1617 2.56  
1.20 1046 1.42 1119 1.61 1193 1.78 1267 1.94 1343 2.09 1419 2.24 1498 2.40 1580 2.58 1665 2.78  
1023 1.44 1097 1.66 1171 1.85 1245 2.03 1319 2.18 1394 2.33 1471 2.49 1550 2.65 1632 2.82 1717 3.02  
1077 1.71 1151 1.93 1225 2.12 1299 2.29 1373 2.45 1448 2.60 1525 2.75 1604 2.91 1686 3.09 1771 3.29  
1133 1.99 1208 2.21 1282 2.41 1356 2.58 1430 2.73 1505 2.88 1582 3.04 1661 3.20 1742 3.37  
-
-
-
-
-
-
1192 2.30 1267 2.52 1341 2.71 1414 2.88 1489 3.04 1564 3.19 1641 3.34  
1253 2.63 1327 2.85 1401 3.04 1475 3.21 1549 3.37  
-
-
-
-
-
-
-
-
-
-
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF102 (8.5 Ton) Bottom Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
4
FS  
674  
Standard 2 HP & Drive  
Hi Static 3 HP & Drive  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
4000  
4200  
0.71  
0.86  
1.01  
1.17  
1.34  
1.53  
1.74  
1.97  
2.21  
731  
746  
764  
785  
808  
833  
861  
892  
924  
0.88  
1.02  
1.17  
1.33  
1.51  
1.70  
1.90  
2.13  
2.37  
786  
801  
819  
840  
863  
888  
916  
947  
979  
1.05  
1.20  
1.35  
1.51  
1.68  
1.87  
2.08  
2.31  
838  
854  
872  
892  
915  
941  
969  
999  
1.24  
1.38  
1.53  
1.69  
1.87  
2.06  
887  
903  
921  
941  
964  
990  
1.42  
1.56  
1.71  
1.87  
933  
948  
966  
987  
1.59  
1.73  
974  
989  
1.74 1010 1.87 1040 1.97 1064 2.03  
1.88 1025 2.01 1056 2.11 1080 2.17  
689  
707  
728  
751  
776  
804  
835  
867  
1.88 1007 2.03 1043 2.16 1074 2.26 1098 2.32  
2.04 1028 2.20 1064 2.33 1094 2.42 1118 2.48  
2.05 1010 2.22 1051 2.37 1087 2.50 1117 2.60 1141 2.66  
2.24 1035 2.41 1076 2.56 1112 2.69 1142 2.79 1167 2.85  
2.26 1018 2.44 1063 2.61 1104 2.77 1140 2.90 1170 2.99 1194  
-
-
-
2.49 1048 2.67 1094 2.84 1135 2.99  
-
-
-
-
-
-
-
-
-
-
2.55 1032 2.73 1081 2.91 1127 3.08  
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932  
4. Field Supplied Drive.  
Johnson Controls Unitary Products  
29  
528194-YTG-F-1210  
ZF120 (10 Ton) Bottom Duct  
Air Flow  
Available External Static Pressure - IWG1  
0.8 1.0 1.2 1.4  
0.2  
0.4  
0.6  
1.6  
1.8  
2.0  
(CFM)  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
Field Supplied Drive  
Standard 2 HP & Drive  
Hi Static 3 HP & Drive  
2600  
2800  
3000  
3200  
3400  
3600  
3800  
4000  
4200  
4400  
4600  
722  
744  
769  
797  
828  
861  
897  
935  
976  
0.83  
0.97  
1.13  
1.32  
1.52  
1.75  
2.00  
2.27  
776  
798  
823  
851  
882  
915  
951  
989  
0.97  
1.12  
1.28  
1.46  
1.67  
1.90  
828  
850  
875  
903  
934  
967  
1.11  
1.26  
1.42  
1.60  
1.81  
878  
900  
925  
953  
983  
1.25  
1.39  
1.55  
926  
949  
974  
1.37  
1.52  
973  
995  
1.50 1018 1.62 1063 1.74 1106 1.86 1149 1.99  
1.64 1041 1.76 1085 1.88 1128 2.00 1171 2.13  
1.68 1020 1.80 1066 1.92 1110 2.05 1153 2.17 1196 2.29  
1.74 1001 1.86 1048 1.99 1093 2.11 1138 2.23 1181 2.35 1224 2.48  
1.94 1032 2.07 1078 2.19 1124 2.32 1168 2.44 1212 2.56 1254 2.68  
2.04 1017 2.17 1065 2.30 1112 2.42 1157 2.54 1201 2.67 1245 2.79 1287 2.91  
2.15 1002 2.29 1052 2.42 1101 2.55 1147 2.67 1193 2.80 1237 2.92 1280 3.04 1323 3.16  
2.42 1041 2.56 1091 2.69 1139 2.82 1186 2.95 1231 3.07 1275 3.19 1319 3.31 1362 3.43  
2.57 1030 2.72 1082 2.86 1132 2.99 1180 3.12 1227 3.24 1272 3.36  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1019 2.88 1073 3.03 1125 3.17 1175 3.30 1223 3.43  
1065 3.22 1119 3.36  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
ZF150 (12.5 Ton) Bottom Duct  
Available External Static Pressure - IWG1  
Air Flow  
(CFM)  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
3 HP & Field Supplied Drive  
Standard 3 HP & Drive  
Hi Static 5 HP & Drive  
3200  
3400  
3600  
3800  
4000  
4200  
4400  
4600  
4800  
5000  
5200  
5400  
5600  
5800  
823  
860  
898  
936  
975  
1.28  
1.48  
1.71  
1.97  
861  
898  
935  
974  
1.47  
1.67  
1.90  
906  
942  
980  
1.64  
1.84  
955  
992  
1.80 1007 1.95 1059 2.12 1109 2.29 1155 2.50 1194 2.73 1225 3.01  
2.00 1044 2.16 1095 2.32 1145 2.50 1191 2.70 1231 2.94 1262 3.22  
2.07 1030 2.23 1081 2.39 1133 2.55 1183 2.73 1229 2.94 1269 3.17 1300 3.45  
2.16 1019 2.33 1068 2.49 1120 2.64 1172 2.81 1222 2.98 1267 3.19 1307 3.42 1338 3.70  
2.24 1013 2.43 1057 2.60 1107 2.76 1158 2.92 1210 3.08 1260 3.26 1306 3.46 1346 3.70 1377 3.97  
1014 2.54 1052 2.73 1096 2.90 1146 3.05 1197 3.21 1249 3.38 1299 3.55 1345 3.76 1385 3.99 1416 4.27  
1053 2.85 1091 3.04 1135 3.21 1185 3.37 1236 3.53 1288 3.69 1338 3.87 1384 4.07 1424 4.31 1455 4.58  
1091 3.19 1129 3.38 1174 3.55 1223 3.71 1275 3.86 1327 4.03 1377 4.20 1423 4.41 1462 4.64 1494 4.92  
1130 3.54 1168 3.73 1213 3.90 1262 4.06 1314 4.22 1365 4.38 1415 4.56 1461 4.76 1501 5.00 1532 5.27  
1168 3.92 1206 4.11 1251 4.28 1300 4.44 1352 4.59 1404 4.76 1454 4.94 1500 5.14 1539 5.37  
-
-
-
-
-
-
-
-
-
-
1206 4.31 1244 4.50 1288 4.67 1338 4.83 1389 4.99 1441 5.15 1491 5.33 1537 5.53  
-
-
-
-
-
-
-
-
1243 4.72 1281 4.91 1326 5.08 1375 5.24 1427 5.40 1479 5.56  
-
-
-
-
-
-
-
-
-
-
-
-
1280 5.15 1318 5.34 1362 5.51  
1316 5.60  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5 HP & Field Supplied Drive  
1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.  
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.  
3. kW = BHP x 0.932.  
30  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
RPM Selection  
Size  
Max  
BHP  
1.73  
2.30  
1.73  
3.45  
2.30  
3.45  
2.30  
3.45  
3.45  
5.75  
Motor  
Sheave  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VP56  
Blower  
Sheave  
AK74  
AK64  
AK74  
AK61  
AK94  
AK74  
AK84  
AK74  
AK74  
BK77  
6 Turns 5 Turns 4 Turns 3 Turns 2 Turns  
1 Turn  
Open  
1084  
1256  
1084  
1312  
843  
Fully  
Closed  
1134  
1308  
1134  
1365  
882  
Model  
HP  
(Tons)  
Open  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
1052  
Open  
Open  
Open  
Open  
1035  
1207  
1035  
1265  
805  
1.5  
2
887  
936  
986  
078  
(6.5)  
ZF  
ZF  
ZF  
ZF  
ZF  
1039  
887  
1094  
936  
1150  
986  
1.5  
3
090  
(7.5)  
1088  
690  
1147  
728  
1205  
767  
2
102  
(8.5)  
3
887  
936  
986  
1035  
906  
1084  
949  
1134  
992  
2
776  
819  
863  
120  
(10)  
3
887  
936  
986  
1035  
1035  
1216  
1084  
1084  
1272  
1134  
1134  
N/A  
3
887  
936  
986  
150  
(12.5)  
5
1095  
1136  
1175  
Additional Static Resistance  
Size  
Electric Heat kW2  
24  
,
Model  
CFM  
Cooling Only1  
Economizer2 3  
4” Filter2  
(Tons)  
9
18  
36  
54  
1900  
2100  
2300  
2500  
2700  
2900  
3100  
3300  
3500  
3700  
3900  
4100  
4300  
4500  
1900  
2100  
2300  
2500  
2700  
2900  
3100  
3300  
3500  
3700  
3900  
4100  
4300  
4500  
4700  
4900  
5100  
5300  
5500  
5700  
5900  
6100  
6300  
0.00  
-0.01  
-0.01  
-0.02  
-0.03  
-0.04  
-0.05  
-0.06  
-0.07  
-0.08  
-0.09  
-0.09  
-0.10  
-0.11  
0.06  
0.07  
0.08  
0.09  
0.11  
0.12  
0.14  
0.16  
0.18  
0.20  
0.23  
0.25  
0.28  
0.30  
0.33  
0.36  
0.39  
0.42  
0.45  
0.48  
0.52  
0.56  
0.60  
0.07  
0.09  
0.11  
0.13  
0.16  
0.18  
0.20  
0.22  
0.24  
0.27  
0.29  
0.31  
0.30  
0.35  
0.02  
0.02  
0.02  
0.02  
0.03  
0.03  
0.03  
0.03  
0.04  
0.04  
0.04  
0.04  
0.05  
0.05  
0.05  
0.05  
0.06  
0.06  
0.06  
0.06  
0.07  
0.07  
0.07  
0.10  
0.11  
0.12  
0.14  
0.15  
0.16  
0.18  
0.19  
0.20  
0.21  
0.23  
0.24  
0.25  
0.26  
0.12  
0.13  
0.14  
0.16  
0.17  
0.19  
0.20  
0.22  
0.26  
0.27  
0.29  
0.32  
0.35  
0.38  
0.41  
0.44  
0.47  
0.51  
0.55  
0.58  
0.62  
0.67  
0.71  
0.05  
0.06  
0.07  
0.08  
0.09  
0.10  
0.12  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
0.25  
0.05  
0.06  
0.07  
0.08  
0.09  
0.10  
0.12  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
0.25  
0.28  
0.30  
0.33  
0.35  
0.38  
0.41  
0.44  
0.47  
0.50  
0.06  
0.07  
0.08  
0.09  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.06  
0.07  
0.08  
0.09  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.29  
0.31  
0.34  
0.37  
0.40  
0.43  
0.46  
0.49  
0.53  
0.07  
0.08  
0.09  
0.10  
0.12  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
0.25  
0.28  
0.30  
0.07  
0.08  
0.09  
0.10  
0.12  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
0.25  
0.28  
0.30  
0.33  
0.35  
0.38  
0.41  
0.44  
0.47  
0.50  
0.53  
0.56  
0.08  
0.09  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.29  
0.31  
0.08  
0.09  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.29  
0.31  
0.34  
0.37  
0.40  
0.43  
0.46  
0.49  
0.53  
0.56  
0.59  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.28  
0.31  
0.34  
0.37  
0.10  
0.11  
0.13  
0.14  
0.16  
0.18  
0.20  
0.22  
0.24  
0.26  
0.28  
0.31  
0.34  
0.37  
0.40  
0.43  
0.46  
0.49  
0.53  
0.56  
0.59  
0.62  
0.65  
078 (6.5)  
090 (7.5)  
ZF  
102 (8.5)  
120 (10)  
150 (12.5)  
ZF  
1. Add these values to the available static resistance in the respective Blower Performance Tables.  
2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables.  
3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is  
less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.  
Johnson Controls Unitary Products  
31  
 
528194-YTG-F-1210  
Drive Selection  
1. Determine side or bottom supply duct Application.  
2. Determine desired airflow.  
3. Calculate or measure the amount of external static pressure.  
4. Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance  
table. (Linear interpolation may be necessary.)  
5. Noting the RPM and BHP from step 4, locate the appropriate motor and, or drive on the RPM selection table.  
6. Review the BHP compared to the motor options available. Select the appropriate motor and, or drive.  
7. Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the  
chosen motor.  
8. Determine turns open to obtain the desired operation point.  
Example  
1. 2600 CFM  
2. 1.6 iwg  
3. Using the supply air blower performance table below, the following data point was located: 1268 RPM & 1.95 BHP.  
4. Using the RPM selection table below, Size X and Model Y is found.  
5. 1.95 BHP exceeds the maximum continuous BHP rating of the 1.5 HP motor. The 2 HP motor is required.  
6. 1268 RPM is within the range of the 2 HP drives.  
7. Using the 2 HP motor and drive, .5 turns open will achieve 1268 RPM.  
Airflow Performance  
Example Supply Air Blower Performance  
Available External Static Pressure - IWG  
Air Flow  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
2.0  
(CFM)  
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP  
1.5 HP & Field Supplied Drive  
Standard 1.5 HP & Drive  
Alternate 2 HP & Drive  
2200  
2400  
2600  
2800  
804  
835  
869  
906  
0.50  
0.66  
0.84  
1.03  
866  
897  
931  
968  
0.71  
0.87  
1.05  
925  
956  
990  
0.90  
982  
1.06 1038 1.21 1092 1.35 1147 1.48 1203 1.61 1259 1.73 1317 1.87  
1.06 1013 1.22 1069 1.37 1124 1.51 1178 1.64 1234 1.77 1290 1.90 1348 2.03  
1.24 1047 1.40 1103 1.55 1158 1.69 1212 1.82 1268 1.95 1324 2.07 1382 2.21  
1.25 1027 1.43 1084 1.60 1139 1.75 1194 1.89 1249 2.02 1304 2.14 1361 2.27  
-
-
Table X: RPM Selection  
Size  
(Tons)  
Max  
BHP  
1.73  
2.30  
Motor  
Sheave  
1VM50  
1VM50  
Blower  
Sheave  
AK74  
6 Turns 5 Turns 4 Turns 3 Turns 2 Turns  
1 Turn  
Open  
1079  
Fully  
Closed  
1126  
Model  
HP  
Open  
Open  
Open  
Open  
Open  
1035  
1207  
1.5  
2
N/A  
897  
945  
991  
X
Y
AK64  
N/A  
1039  
1094  
1150  
1256  
1308  
32  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Altitude/Temperature Correction Factors  
Air  
Altitude (Ft.)  
5000  
Temp.  
40  
0
1000  
1.022  
1.002  
0.982  
0.964  
0.947  
0.929  
0.912  
2000  
0.986  
0.966  
0.948  
0.930  
0.913  
0.897  
0.880  
3000  
0.950  
0.931  
0.913  
0.896  
0.880  
0.864  
0.848  
4000  
0.916  
0.898  
0.880  
0.864  
0.848  
0.833  
0.817  
6000  
0.849  
0.832  
0.816  
0.801  
0.787  
0.772  
0.758  
7000  
0.818  
0.802  
0.787  
0.772  
0.758  
0.744  
0.730  
8000  
0.788  
0.772  
0.757  
0.743  
0.730  
0.716  
0.703  
9000  
0.758  
0.743  
0.729  
0.715  
0.702  
0.689  
0.676  
10000  
0.729  
0.715  
0.701  
0.688  
0.676  
0.663  
0.651  
1.060  
1.039  
1.019  
1.000  
0.982  
0.964  
0.946  
0.882  
0.864  
0.848  
0.832  
0.817  
0.802  
0.787  
50  
60  
70  
80  
90  
100  
1.100  
1.050  
1.000  
0.950  
0.900  
0.850  
0.800  
0.750  
0.700  
0.650  
0.600  
Sea Level  
1000 ft  
2000 ft  
3000 ft  
4000 ft  
5000 ft  
6000 ft  
7000 ft  
8000 ft  
9000 ft  
10000 ft  
40  
50  
60  
70  
80  
90  
100  
Air Temperature (ºF)  
Johnson Controls Unitary Products  
33  
528194-YTG-F-1210  
Gas Heat Minimum Supply Air  
Supply Air (CFM)  
Size  
Model  
(Tons)  
Heat Size  
Cooling  
Heating  
Min  
Max  
3250  
3250  
3750  
3750  
4250  
4250  
5000  
5000  
6250  
6250  
Min  
Max  
3250  
3250  
3750  
3750  
4250  
4250  
5000  
5000  
6250  
6250  
10  
15  
10  
15  
10  
15  
15  
20  
15  
20  
1950  
1950  
2250  
2250  
2550  
2550  
3000  
3000  
3750  
3750  
1950  
1950  
2250  
2250  
2550  
2550  
3000  
3000  
3750  
3750  
078  
(6.5)  
ZF  
ZF  
ZF  
ZF  
ZF  
090  
(7.5)  
102  
(8.5)  
120  
(10)  
150  
(12.5)  
Electric Heat Minimum Supply Air  
Minimum Supply Air (CFM)  
Heater kW  
Size  
Model  
(Tons)  
Voltage  
9
1950  
1950  
1950  
2250  
2250  
2250  
2550  
2550  
2550  
-
18  
24  
36  
54  
-
-
-
-
-
-
-
208/230-3-60  
460-3-60  
600-3-60  
208/230-3-60  
460-3-60  
600-3-60  
208/230-3-60  
460-3-60  
600-3-60  
208/230-3-60  
460-3-60  
600-3-60  
1950  
1950  
1950  
2250  
2250  
2250  
2550  
2550  
2550  
3000  
3000  
3000  
3750  
3750  
3750  
1950  
1950  
1950  
2250  
2250  
2250  
2550  
2550  
2550  
3000  
3000  
3000  
3750  
3750  
3750  
1950  
1950  
1950  
2250  
2250  
2250  
2550  
2550  
2550  
3000  
3000  
3000  
3750  
3750  
3750  
078  
(6.5)  
ZF  
090  
(7.5)  
ZF  
102  
(8.5)  
ZF  
-
-
3500  
3000  
3500  
4000  
3750  
3750  
120  
(10)  
ZF  
-
-
-
-
208/230-3-60  
460-3-60  
600-3-60  
150  
(12.5)  
ZF  
-
Indoor Blower Specifications  
Motor  
RPM Eff.  
Motor Sheave  
Blower Sheave  
Size  
(Tons)  
Model  
Belt  
Datum Dia.  
(in.)  
Datum Dia.  
(in.)  
7.0  
HP  
SF  
Frame  
Bore (in.) Model  
Bore (in.)  
Model  
1-1/2 1725  
1725  
1-1/2 1725  
0.8  
0.8  
0.8  
0.8  
0.8  
0.8  
0.8  
0.8  
0.8  
1.15  
1.15  
1.15  
1.15  
1.15  
1.15  
1.15  
1.15  
1.15  
56  
56  
56  
56  
56  
56  
56  
56  
56  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
3.4 - 4.4  
4.3 - 5.3  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
1-1/8  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VM50  
1VP56  
1
1
1
1
1
1
1
1
1
1
AK74  
AK64  
AK74  
AK61  
AK94  
AK74  
AK84  
AK74  
AK74  
BK77  
A49  
A49  
A49  
A49  
A56  
A54  
A56  
A54  
A54  
BX55  
078  
(6.5)  
090  
ZF  
ZF  
ZF  
ZF  
ZF  
2
6.0  
7.0  
5.7  
9.0  
7.0  
8.0  
7.0  
7.0  
(7.5)  
3
2
3
2
3
3
5
1725  
1725  
1725  
1725  
1725  
1725  
102  
(8.5)  
120  
(10)  
150  
(12.5)  
1725 0.87 1.15  
184T  
6.7  
Power Exhaust Specifications  
Motor  
RPM1  
Motor  
CFM @  
0.1 ESP  
Model  
Voltage  
Fuse Size  
HP  
3/4  
3/4  
3/4  
QTY  
LRA  
7.8  
FLA  
5
MCA  
6.3  
2PE04703225  
2PE04703246  
2PE04703258  
208/230-1-60  
460-1-60  
1075  
1075  
1050  
1
1
1
10  
5
3800  
3.4  
2.2  
1.5  
2.8  
3800  
575-1-60  
2.9  
1.9  
4
3800  
1. Motors are multi-tapped and factory wired for high speed.  
34  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Electric Heat Multipliers  
Voltage  
kW Capacity Multipliers1  
Nominal  
Applied  
208  
0.75  
0.92  
0.92  
0.92  
240  
230  
480  
600  
460  
575  
1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat  
capacity for heaters applied at lower voltages.  
Sound Performance  
Indoor Sound Power Levels  
Sound Power, dB (10-12) Watts  
Octave Band Centerline Frequency (Hz)  
Blower  
Size  
(Tons)  
ESP  
(IWG)  
Sound Rating1  
dB (A)  
Model  
CFM  
RPM  
BHP  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
078  
(6.5)  
ZF  
ZF  
ZF  
ZF  
ZF  
2600  
3000  
3400  
4000  
5000  
0.6  
0.6  
0.6  
0.6  
0.6  
812  
854  
872  
959  
1132  
1.14  
74  
77  
80  
83  
87  
71  
73  
73  
71  
69  
65  
65  
60  
090  
(7.5)  
1.47  
1.65  
2.29  
3.74  
74  
77  
80  
84  
76  
79  
82  
86  
76  
79  
82  
86  
74  
77  
80  
84  
72  
75  
78  
82  
68  
71  
74  
78  
68  
71  
74  
78  
63  
66  
69  
73  
102  
(8.5)  
120  
(10)  
150  
(12.5)  
1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values  
provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way  
of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data  
in any other form than sound power level ratings.  
Outdoor Sound Power Levels  
ZF078-150  
Octave Band Centerline Frequency (Hz)  
Size  
(Tons)  
Sound Rating1  
dB (A)  
Model  
ZF  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
078  
(6.5)  
84  
89  
91  
92  
88  
86.0  
87.5  
86.0  
82.5  
79.0  
73.5  
68.5  
62.0  
090  
(7.5)  
ZF  
89.5  
91.5  
99.5  
91.0  
92.0  
93.5  
94.5  
92.5  
89.0  
92.5  
92.0  
90.0  
87.5  
89.0  
90.0  
85.0  
84.0  
85.5  
87.0  
81.5  
78.5  
80.5  
81.0  
77.0  
73.5  
76.0  
76.0  
73.0  
66.5  
71.0  
70.0  
66.5  
102  
(8.5)  
ZF  
120  
(10)  
ZF  
150  
(12.5)  
ZF  
1. Rated in accordance with ARI 270 standard.  
Johnson Controls Unitary Products  
35  
 
528194-YTG-F-1210  
Electrical Data  
ZF078-150 Standard Motor - Without Powered Convenience Outlet  
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/  
Pwr Exh  
(Amps)  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW  
Stages  
Amps  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
-
6.8  
13.5  
18  
25.5  
-
-
-
29.9  
31.1  
54.3  
70  
35.4  
38  
35  
35  
60  
70  
100  
35  
35  
70  
80  
110  
20  
20  
35  
40  
60  
15  
15  
25  
35  
45  
50  
50  
60  
70  
100  
50  
50  
70  
80  
110  
20  
20  
35  
40  
60  
20  
20  
25  
35  
45  
50  
50  
60  
80  
100  
50  
50  
70  
90  
125  
25  
25  
35  
45  
60  
20  
20  
25  
35  
45  
40  
40  
70  
80  
110  
40  
45  
70  
90  
125  
20  
20  
35  
45  
60  
15  
20  
30  
35  
50  
50  
50  
70  
80  
110  
50  
50  
70  
90  
125  
25  
25  
35  
45  
60  
20  
20  
30  
35  
50  
50  
50  
70  
80  
110  
50  
50  
70  
90  
125  
25  
25  
35  
45  
60  
20  
20  
30  
35  
50  
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
10.8  
21.7  
28.9  
40.9  
-
208 9.3  
230 9.3  
460 4.9  
575 3.8  
208 11.9  
230 11.9  
460 5.2  
575 4.8  
208 12.2  
230 12.2  
460 5.8  
575 4.4  
68  
68  
34  
28  
88  
88  
44  
36  
88  
88  
44  
36  
14.5  
14.5  
7.7  
6
1.5  
6.0  
5.5  
0
61.2  
76.8  
102.9  
35.4  
41.4  
68.5  
86.5  
116.6  
17.8  
20  
96  
29.9  
34.6  
61.6  
79.7  
109.7  
15.6  
17.3  
30.8  
39.8  
54.9  
12.2  
13.8  
24.7  
31.9  
43.9  
39.8  
39.8  
54.3  
70  
9
1.5  
0.8  
0.6  
3.5  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.0  
3.0  
2.4  
6.0  
6.0  
3.0  
2.4  
6.8  
6.8  
3.4  
2.7  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
0
0
0
0
0
0
0
0
0
0
0
18  
24  
34  
-
078  
(6.5)  
9
18  
24  
34  
-
33.6  
42.6  
57.6  
14  
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
8.7  
16.1  
26.9  
34.1  
46.1  
45.3  
45.3  
61.2  
76.8  
102.9  
45.3  
45.3  
68.5  
86.5  
116.6  
20.1  
20.1  
33.6  
42.6  
57.6  
17.6  
17.6  
26.9  
34.1  
46.1  
46.8  
46.8  
62.2  
77.8  
103.9  
46.8  
46.8  
69.5  
87.5  
117.6  
21.9  
21.9  
34.1  
43.1  
58.1  
17  
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
18.5  
18.5  
8.1  
7.5  
19  
96  
39.8  
39.8  
61.6  
79.7  
109.7  
17.9  
17.9  
30.8  
39.8  
54.9  
15.8  
15.8  
24.7  
31.9  
43.9  
41.3  
41.3  
55.3  
71  
9
18  
24  
34  
-
090  
(7.5)  
9
1
2
2
2
-
10.8  
21.7  
28.9  
40.9  
-
18  
24  
34  
-
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
8.7  
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
97  
41.3  
41.3  
62.6  
80.7  
110.7  
19.7  
19.7  
31.3  
40.3  
55.4  
15.2  
15.2  
25  
9
19  
18  
24  
34  
-
102  
(8.5)  
9
1
2
2
2
-
1
2
2
2
10.8  
21.7  
28.9  
40.9  
-
9
18  
24  
34  
-
9
8.7  
17  
5.5  
18  
24  
34  
17.3  
23.1  
32.7  
27.3  
34.5  
46.5  
32.2  
44.3  
36  
Johnson Controls Unitary Products  
 
528194-YTG-F-1210  
ZF078-150 Standard Motor - Without Powered Convenience Outlet (Continued)  
2
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
1
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
3
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/  
Pwr Exh  
(Amps)  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW  
Stages  
Amps  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
-
13.5  
18  
25.5  
40.6  
-
18  
24  
34  
54  
-
-
-
45.1  
55.3  
71  
50.6  
62.2  
77.8  
103.9  
156.2  
50.6  
69.5  
87.5  
117.6  
145.3  
25.5  
34.1  
43.1  
58.1  
72  
19.7  
27.3  
34.5  
46.5  
57.6  
81.1  
81.1  
81.3  
107.4  
159.7  
81.1  
81.1  
91.0  
121.1  
148.8  
40.9  
40.9  
44.8  
59.9  
73.7  
30.5  
30.5  
36.0  
48.0  
59.1  
50  
60  
60  
70  
2
2
2
2
-
2
2
2
2
-
37.5  
50.0  
70.8  
112.7  
-
43.3  
57.7  
81.8  
129.9  
-
208 13.9 110 21.7  
3.5  
6.8  
5.5  
0
80  
80  
97  
100  
150  
50  
70  
90  
110  
175  
60  
70  
90  
149.4  
45.1  
62.6  
80.7  
110.7  
138.4  
23.3  
31.3  
40.3  
55.4  
69.2  
17.9  
25  
230 13.9 110 21.7  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.8  
3.4  
2.7  
9.6  
9.6  
4.8  
3.9  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
0
0
0
0
0
0
0
125  
150  
30  
125  
175  
30  
120  
(10)  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
13.5  
18  
25.5  
40.6  
-
2
2
2
2
-
2
2
2
2
-
2
2
2
2
-
21.7  
28.9  
40.9  
65.0  
-
17.3  
23.1  
32.7  
52.0  
-
37.5  
50.0  
70.8  
112.7  
-
35  
45  
60  
35  
45  
60  
460 7.4  
55  
43  
11.5  
8.7  
36  
80  
20  
25  
80  
25  
30  
575 5.6  
32.2  
44.3  
55.3  
75.6  
75.6  
75.6  
100.5  
152.9  
75.6  
75.6  
84.2  
114.2  
141.9  
38.7  
38.7  
42.1  
57.1  
71.0  
28.7  
28.7  
33.7  
45.8  
56.8  
35  
45  
60  
35  
50  
60  
90  
90  
90  
100  
100  
100  
110  
175  
100  
100  
100  
125  
175  
50  
208 23.1 160  
110  
175  
90  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
2
2
2
2
-
2
2
2
2
-
43.3  
57.7  
81.8  
129.9  
-
21.7  
28.9  
40.9  
65.0  
-
90  
90  
125  
175  
50  
230 23.1 160  
36  
150  
(12.5)  
50  
50  
460 12.2  
87  
62  
19  
50  
60  
80  
50  
60  
80  
35  
35  
35  
35  
35  
40  
18  
24  
34  
54  
2
2
2
2
17.3  
23.1  
32.7  
52.0  
575 8.7  
13.5  
50  
70  
50  
70  
1. Minimum Circuit Ampacity.  
2. Dual Element, Time Delay Type.  
3. HACR type per NEC.  
Johnson Controls Unitary Products  
37  
   
528194-YTG-F-1210  
ZF078-150 Hi Static Motor - Without Powered Convenience Outlet  
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
-
6.8  
13.5  
18  
25.5  
-
-
-
30.7  
32.1  
55.3  
71  
36.2  
39  
40  
40  
60  
80  
100  
40  
40  
70  
90  
125  
20  
20  
35  
45  
60  
15  
15  
25  
35  
45  
50  
50  
60  
80  
110  
50  
50  
70  
90  
125  
20  
20  
35  
45  
60  
20  
20  
30  
35  
50  
50  
50  
60  
80  
110  
50  
50  
70  
90  
125  
25  
25  
35  
45  
60  
20  
20  
30  
35  
50  
45  
45  
70  
80  
110  
45  
45  
70  
90  
125  
20  
25  
35  
45  
60  
15  
20  
30  
35  
50  
60  
60  
70  
90  
110  
60  
60  
80  
100  
125  
25  
25  
40  
45  
60  
20  
20  
30  
40  
50  
60  
60  
70  
90  
110  
60  
60  
80  
100  
125  
25  
25  
40  
45  
60  
20  
20  
30  
40  
50  
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
10.8  
21.7  
28.9  
40.9  
-
208 9.3  
230 9.3  
460 4.9  
575 3.8  
208 11.9  
230 11.9  
460 5.2  
575 4.8  
208 12.2  
230 12.2  
460 5.8  
575 4.4  
68  
68  
34  
28  
88  
88  
44  
36  
88  
88  
44  
36  
14.5  
14.5  
7.7  
6
1.5  
6.8  
5.5  
0
62.2  
77.8  
103.9  
36.2  
42.4  
69.5  
87.5  
117.6  
18.2  
20.5  
34.1  
43.1  
58.1  
14.3  
16.5  
27.3  
34.5  
46.5  
48.9  
48.9  
65.7  
81.3  
107.4  
48.9  
48.9  
73  
97  
30.7  
35.6  
62.6  
80.7  
110.7  
16  
17.8  
31.3  
40.3  
55.4  
12.5  
14.2  
25  
9
1.5  
0.8  
0.6  
3.5  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.8  
3.4  
2.7  
9.6  
9.6  
4.8  
3.9  
9.6  
9.6  
4.8  
3.9  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
0
0
0
0
0
0
0
0
0
0
0
18  
24  
34  
-
078  
(6.5)  
9
18  
24  
34  
-
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
8.7  
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
32.2  
44.3  
43.4  
43.4  
58.8  
74.5  
100.5  
43.4  
43.4  
66.1  
84.2  
114.2  
19.7  
19.7  
33.1  
42.1  
57.1  
17.3  
17.3  
26.5  
33.7  
45.8  
44.1  
44.1  
58.8  
74.5  
100.5  
44.1  
44.1  
66.1  
84.2  
114.2  
21.1  
21.1  
33.1  
42.1  
57.1  
16.4  
16.4  
26.5  
33.7  
45.8  
18.5  
18.5  
8.1  
7.5  
19  
9
18  
24  
34  
-
91  
121.1  
21.9  
22.3  
35.8  
44.8  
59.9  
19.1  
19.1  
28.8  
36  
090  
(7.5)  
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
10.8  
21.7  
28.9  
40.9  
-
18  
24  
34  
-
9
8.7  
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
48  
49.6  
49.6  
65.7  
81.3  
107.4  
49.6  
49.6  
73  
9
19  
18  
24  
34  
-
91  
121.1  
23.3  
23.3  
35.8  
44.8  
59.9  
18.2  
18.2  
28.8  
36  
102  
(8.5)  
9
1
2
2
2
-
1
2
2
2
10.8  
21.7  
28.9  
40.9  
-
9
18  
24  
34  
-
9
8.7  
5.5  
18  
24  
34  
17.3  
23.1  
32.7  
48  
38  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued)  
2
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
1
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
3
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
-
13.5  
18  
25.5  
40.6  
-
18  
24  
34  
54  
-
-
-
47.9  
58.8  
74.5  
100.5  
152.9  
47.9  
66.1  
84.2  
114.2  
141.9  
24.7  
33.1  
42.1  
57.1  
71  
19.1  
26.5  
33.7  
45.8  
56.8  
81.2  
81.2  
81.5  
107.5  
159.9  
81.2  
81.2  
91.2  
121.2  
148.9  
41.5  
41.5  
45.6  
60.6  
74.5  
30.9  
30.9  
36.5  
48.5  
59.6  
53.4  
65.7  
81.3  
107.4  
159.7  
53.4  
73  
60  
60  
60  
70  
2
2
2
2
-
2
2
2
2
-
37.5  
50.0  
70.8  
112.7  
-
43.3  
57.7  
81.8  
129.9  
-
208 13.9 110 21.7  
3.5  
9.6  
5.5  
0
80  
90  
110  
175  
60  
70  
90  
110  
175  
60  
80  
230 13.9 110 21.7  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
9.6  
4.8  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
0
0
0
0
0
0
0
91  
100  
125  
175  
30  
121.1  
148.8  
26.9  
35.8  
44.8  
59.9  
73.7  
20.9  
28.8  
36  
125  
175  
30  
120  
(10)  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
13.5  
18  
25.5  
40.6  
-
2
2
2
2
-
2
2
2
2
-
2
2
2
2
-
21.7  
28.9  
40.9  
65.0  
-
17.3  
23.1  
32.7  
52.0  
-
37.5  
50.0  
70.8  
112.7  
-
35  
45  
60  
40  
45  
60  
460 7.4  
55  
43  
11.5  
8.7  
36  
80  
20  
30  
80  
25  
30  
575 5.6  
3.9  
35  
50  
70  
40  
50  
70  
48  
59.1  
86.7  
86.7  
88.3  
114.4  
166.7  
86.7  
86.7  
98.0  
128.1  
155.8  
43.7  
43.7  
48.3  
63.4  
77.2  
32.7  
32.7  
38.7  
50.8  
61.8  
100  
100  
100  
110  
175  
100  
100  
100  
125  
175  
50  
100  
100  
100  
125  
175  
100  
100  
100  
150  
175  
50  
208 23.1 160  
15.2  
15.2  
7.6  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
2
2
2
2
-
2
2
2
2
-
43.3  
57.7  
81.8  
129.9  
-
21.7  
28.9  
40.9  
65.0  
-
230 23.1 160  
36  
150  
(12.5)  
50  
50  
460 12.2  
87  
62  
19  
50  
70  
90  
50  
70  
90  
35  
35  
40  
40  
40  
40  
18  
24  
34  
54  
2
2
2
2
17.3  
23.1  
32.7  
52.0  
575 8.7  
13.5  
6.1  
50  
70  
60  
70  
1. Minimum Circuit Ampacity.  
2. Dual Element, Time Delay Type.  
3. HACR type per NEC.  
Johnson Controls Unitary Products  
39  
     
528194-YTG-F-1210  
ZF078-150 Standard Motor - With Powered Convenience Outlet  
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
-
6.8  
13.5  
18  
25.5  
-
-
-
40.1  
43.6  
66.8  
82.5  
108.5  
40.1  
47.1  
74.1  
92.2  
122.2  
20.7  
23.5  
37.1  
46.1  
61.1  
16.2  
18.8  
29.7  
36.9  
48.9  
49.8  
49.8  
66.8  
82.5  
108.5  
49.8  
49.8  
74.1  
92.2  
122.2  
22.9  
23.5  
37.1  
46.1  
61.1  
19.8  
19.8  
29.7  
36.9  
48.9  
51.3  
51.3  
67.8  
83.5  
109.5  
51.3  
51.3  
75.1  
93.2  
123.2  
24.7  
24.7  
37.6  
46.6  
61.6  
19.2  
19.2  
30  
45.6  
50.5  
73.7  
89.3  
115.4  
45.6  
53.9  
81  
50  
50  
70  
90  
110  
50  
50  
80  
100  
125  
25  
25  
40  
50  
70  
20  
20  
30  
40  
50  
60  
60  
70  
90  
110  
60  
60  
80  
100  
125  
25  
25  
40  
50  
70  
20  
20  
30  
40  
50  
60  
60  
70  
90  
110  
60  
60  
80  
100  
125  
30  
30  
40  
50  
70  
20  
20  
30  
40  
50  
50  
60  
80  
90  
125  
50  
60  
90  
100  
150  
25  
30  
40  
50  
70  
20  
25  
35  
40  
60  
60  
60  
80  
90  
125  
60  
60  
90  
100  
150  
30  
30  
40  
50  
70  
25  
25  
35  
40  
60  
60  
60  
80  
100  
125  
60  
60  
90  
100  
150  
30  
30  
45  
50  
70  
25  
25  
35  
40  
60  
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
10.8  
21.7  
28.9  
40.9  
-
208 9.3  
230 9.3  
460 4.9  
575 3.8  
208 11.9  
230 11.9  
460 5.2  
575 4.8  
208 12.2  
230 12.2  
460 5.8  
575 4.4  
68  
68  
34  
28  
88  
88  
44  
36  
88  
88  
44  
36  
14.5  
14.5  
7.7  
6
1.5  
6.0  
5.5  
10  
9
1.5  
0.8  
0.6  
3.5  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.0  
3.0  
2.4  
6.0  
6.0  
3.0  
2.4  
6.8  
6.8  
3.4  
2.7  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
10  
5
18  
24  
34  
-
99  
129.1  
22.9  
26.3  
39.8  
48.8  
63.9  
18  
078  
(6.5)  
9
18  
24  
34  
-
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
8.7  
21.1  
31.9  
39.1  
51.1  
55.3  
55.3  
73.7  
89.3  
115.4  
55.3  
55.3  
81  
4
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
18.5  
18.5  
8.1  
7.5  
19  
10  
10  
5
9
18  
24  
34  
-
99  
129.1  
25.1  
26.3  
39.8  
48.8  
63.9  
21.6  
21.6  
31.9  
39.1  
51.1  
56.8  
56.8  
74.7  
90.3  
116.4  
56.8  
56.8  
82  
090  
(7.5)  
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
10.8  
21.7  
28.9  
40.9  
-
18  
24  
34  
-
9
8.7  
4
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
10  
10  
5
9
19  
18  
24  
34  
-
100  
130.1  
26.9  
26.9  
40.3  
49.3  
64.4  
21  
21.5  
32.3  
39.5  
51.5  
102  
(8.5)  
9
1
2
2
2
-
1
2
2
2
10.8  
21.7  
28.9  
40.9  
-
9
18  
24  
34  
-
9
8.7  
5.5  
4
18  
24  
34  
17.3  
23.1  
32.7  
37.2  
49.3  
40  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Standard Motor - With Powered Convenience Outlet (Continued)  
2
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
1
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
3
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
-
13.5  
18  
25.5  
40.6  
-
18  
24  
34  
54  
-
-
-
55.1  
67.8  
83.5  
109.5  
161.9  
55.1  
75.1  
93.2  
123.2  
150.9  
28.3  
37.6  
46.6  
61.6  
75.5  
21.9  
30  
60.6  
74.7  
90.3  
116.4  
168.7  
60.6  
82  
60  
70  
70  
80  
2
2
2
2
-
2
2
2
2
-
37.5  
50.0  
70.8  
112.7  
-
43.3  
57.7  
81.8  
129.9  
-
208 13.9 110 21.7  
3.5  
6.8  
5.5  
10  
90  
100  
125  
175  
70  
110  
175  
60  
80  
90  
230 13.9 110 21.7  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.8  
3.4  
2.7  
9.6  
9.6  
4.8  
3.9  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
10  
5
100  
100  
125  
175  
35  
100  
150  
175  
35  
130.1  
157.8  
30.5  
40.3  
49.3  
64.4  
78.2  
23.7  
32.3  
39.5  
51.5  
62.6  
91.1  
91.1  
93.8  
119.9  
172.2  
91.1  
91.1  
103.5  
133.6  
161.3  
45.9  
45.9  
51.1  
66.1  
80.0  
34.5  
34.5  
41.0  
53.0  
64.1  
120  
(10)  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
13.5  
18  
25.5  
40.6  
-
2
2
2
2
-
2
2
2
2
-
2
2
2
2
-
21.7  
28.9  
40.9  
65.0  
-
17.3  
23.1  
32.7  
52.0  
-
37.5  
50.0  
70.8  
112.7  
-
40  
50  
70  
45  
50  
70  
460 7.4  
55  
43  
11.5  
8.7  
36  
80  
25  
30  
90  
25  
35  
575 5.6  
4
37.2  
49.3  
60.3  
85.6  
85.6  
87.0  
113.0  
165.4  
85.6  
85.6  
96.7  
126.7  
154.4  
43.7  
43.7  
48.3  
63.4  
77.2  
32.7  
32.7  
38.7  
50.8  
61.8  
40  
50  
70  
40  
60  
70  
100  
100  
100  
125  
175  
100  
100  
100  
150  
175  
50  
110  
110  
110  
125  
175  
110  
110  
110  
150  
175  
50  
208 23.1 160  
10  
10  
5
18  
24  
34  
54  
-
18  
24  
34  
54  
-
2
2
2
2
-
2
2
2
2
-
43.3  
57.7  
81.8  
129.9  
-
21.7  
28.9  
40.9  
65.0  
-
230 23.1 160  
36  
150  
(12.5)  
50  
50  
460 12.2  
87  
62  
19  
50  
70  
90  
60  
70  
90  
40  
40  
40  
40  
40  
45  
18  
24  
34  
54  
2
2
2
2
17.3  
23.1  
32.7  
52.0  
575 8.7  
13.5  
4
60  
70  
60  
70  
1. Minimum Circuit Ampacity.  
2. Dual Element, Time Delay Type.  
3. HACR type per NEC.  
Johnson Controls Unitary Products  
41  
     
528194-YTG-F-1210  
ZF078-150 Hi Static Motor - With Powered Convenience Outlet  
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
None  
E09  
E18  
E24  
E36  
-
6.8  
13.5  
18  
25.5  
-
-
-
40.9  
44.6  
67.8  
83.5  
109.5  
40.9  
48.1  
75.1  
93.2  
123.2  
21.1  
24  
37.6  
46.6  
61.6  
16.5  
19.2  
30  
46.4  
51.5  
74.7  
90.3  
116.4  
46.4  
54.9  
82  
50  
50  
70  
90  
110  
50  
50  
80  
100  
125  
25  
25  
40  
50  
70  
20  
20  
30  
40  
50  
60  
60  
80  
90  
125  
60  
60  
80  
100  
150  
25  
30  
40  
50  
70  
25  
25  
35  
40  
60  
60  
60  
80  
90  
125  
60  
60  
80  
100  
150  
30  
30  
40  
50  
70  
25  
25  
35  
40  
60  
50  
60  
80  
100  
125  
50  
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
10.8  
21.7  
28.9  
40.9  
-
208 9.3  
230 9.3  
460 4.9  
575 3.8  
208 11.9  
230 11.9  
460 5.2  
575 4.8  
208 12.2  
230 12.2  
460 5.8  
575 4.4  
68  
68  
34  
28  
88  
88  
44  
36  
88  
88  
44  
36  
14.5  
14.5  
7.7  
6
1.5  
6.8  
5.5  
10  
9
60  
1.5  
0.8  
0.6  
3.5  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
6.8  
3.4  
2.7  
9.6  
9.6  
4.8  
3.9  
9.6  
9.6  
4.8  
3.9  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
10  
5
18  
24  
34  
-
90  
100  
100  
150  
25  
30  
45  
130.1  
23.3  
26.8  
40.3  
49.3  
64.4  
18.3  
21.5  
32.3  
39.5  
51.5  
58.9  
58.9  
78.2  
93.8  
119.9  
58.9  
58.9  
85.5  
103.5  
133.6  
26.9  
28.5  
42.1  
51.1  
66.1  
23.1  
23.1  
33.8  
41  
078  
(6.5)  
9
18  
24  
34  
-
50  
70  
20  
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
8.7  
25  
35  
40  
4
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
37.2  
49.3  
53.4  
53.4  
71.3  
87  
60  
70  
70  
18.5  
18.5  
8.1  
7.5  
19  
10  
10  
5
80  
100  
125  
70  
70  
90  
113  
53.4  
53.4  
78.6  
96.7  
126.7  
24.7  
25.8  
39.3  
48.3  
63.4  
21.3  
21.3  
31.5  
38.7  
50.8  
54.1  
54.1  
71.3  
87  
9
18  
24  
34  
-
110  
150  
30  
090  
(7.5)  
9
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
1
2
2
2
-
10.8  
21.7  
28.9  
40.9  
-
30  
45  
60  
18  
24  
34  
-
70  
25  
25  
9
8.7  
4
18  
24  
34  
-
6.8  
13.5  
18  
25.5  
-
17.3  
23.1  
32.7  
-
18.9  
37.5  
50.0  
70.8  
-
21.7  
43.3  
57.7  
81.8  
-
35  
45  
53  
60  
70  
70  
59.6  
59.6  
78.2  
93.8  
119.9  
59.6  
59.6  
85.5  
103.5  
133.6  
28.3  
28.5  
42.1  
51.1  
66.1  
22.2  
23  
10  
10  
5
80  
100  
125  
70  
70  
90  
113  
54.1  
54.1  
78.6  
96.7  
126.7  
26.1  
26.1  
39.3  
48.3  
63.4  
20.4  
20.7  
31.5  
38.7  
50.8  
9
19  
18  
24  
34  
-
110  
150  
30  
102  
(8.5)  
9
1
2
2
2
-
1
2
2
2
10.8  
21.7  
28.9  
40.9  
-
30  
45  
60  
9
18  
24  
34  
-
70  
25  
25  
9
8.7  
5.5  
4
18  
24  
34  
17.3  
23.1  
32.7  
33.8  
41  
53  
35  
45  
60  
42  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Hi Static Motor - With Powered Convenience Outlet (Continued)  
2
OD Fan Supply  
Pwr  
Exh  
Motor Outlet  
Pwr  
Conv  
Max Fuse /  
Breaker  
1
2
Compressors  
(each)  
MCA  
Max Fuse /  
Breaker  
Size  
(Amps)  
3
Motors  
(each)  
Blower  
Motor  
Electric Heat Option  
1
3
Size  
(Tons)  
MCA  
w/Pwr  
Exh  
(Amps)  
Volt  
Size w/ Pwr  
Exh  
(Amps)  
RLA LRA MCC  
FLA  
FLA  
FLA  
FLA  
Model  
kW Stages Amps  
(Amps)  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
None  
E18  
E24  
E36  
E54  
-
13.5  
18  
25.5  
40.6  
-
18  
24  
34  
54  
-
-
-
57.9  
71.3  
87  
63.4  
78.2  
93.8  
119.9  
172.2  
63.4  
85.5  
103.5  
133.6  
161.3  
31.9  
42.1  
51.1  
66.1  
80  
70  
80  
70  
80  
2
2
2
2
-
2
2
2
2
-
37.5  
50.0  
70.8  
112.7  
-
43.3  
57.7  
81.8  
129.9  
-
208 13.9 110 21.7  
3.5  
9.6  
5.5  
10  
90  
100  
125  
175  
70  
113  
125  
175  
70  
165.4  
57.9  
78.6  
96.7  
126.7  
154.4  
29.7  
39.3  
48.3  
63.4  
77.2  
23.1  
31.5  
38.7  
50.8  
61.8  
91.2  
91.2  
94.0  
120.0  
172.4  
91.2  
91.2  
103.7  
133.7  
161.4  
46.5  
46.5  
51.8  
66.9  
80.7  
34.9  
34.9  
41.5  
53.5  
64.6  
80  
90  
230 13.9 110 21.7  
3.5  
1.6  
1.3  
3.5  
3.5  
1.6  
1.3  
9.6  
4.8  
5.5  
2.2  
1.8  
5.5  
5.5  
2.2  
1.8  
10  
5
100  
150  
175  
35  
110  
150  
175  
35  
120  
(10)  
18  
24  
34  
54  
-
18  
24  
34  
54  
-
13.5  
18  
25.5  
40.6  
-
2
2
2
2
-
2
2
2
2
-
2
2
2
2
-
21.7  
28.9  
40.9  
65.0  
-
17.3  
23.1  
32.7  
52.0  
-
37.5  
50.0  
70.8  
112.7  
-
40  
50  
70  
45  
60  
70  
460 7.4  
55  
43  
11.5  
8.7  
36  
90  
25  
35  
90  
30  
35  
24.9  
33.8  
41  
575 5.6  
3.9  
4
40  
60  
70  
45  
60  
70  
53  
64.1  
96.7  
96.7  
100.8  
126.9  
179.2  
96.7  
96.7  
110.5  
140.6  
168.3  
48.7  
48.7  
54.6  
69.6  
83.5  
36.7  
36.7  
43.7  
55.8  
66.8  
110  
110  
110  
125  
175  
110  
110  
110  
150  
175  
50  
110  
110  
110  
150  
200  
110  
110  
125  
150  
175  
60  
208 23.1 160  
15.2  
15.2  
7.6  
10  
10  
5
18  
24  
34  
54  
-
18  
24  
34  
54  
-
2
2
2
2
-
2
2
2
2
-
43.3  
57.7  
81.8  
129.9  
-
21.7  
28.9  
40.9  
65.0  
-
230 23.1 160  
36  
150  
(12.5)  
50  
60  
460 12.2  
87  
62  
19  
60  
70  
90  
60  
70  
90  
40  
40  
45  
45  
45  
45  
18  
24  
34  
54  
2
2
2
2
17.3  
23.1  
32.7  
52.0  
575 8.7  
13.5  
6.1  
4
60  
70  
60  
70  
1. Minimum Circuit Ampacity.  
2. Dual Element, Time Delay Type.  
3. HACR type per NEC.  
Johnson Controls Unitary Products  
43  
     
528194-YTG-F-1210  
Typical Wiring Diagrams  
ZF078-150 Typical Wiring Diagrams  
Typical ZF078-120 Cooling Unit with Gas Heat 230 Volt Wiring Diagram  
44  
Johnson Controls Unitary Products  
 
528194-YTG-F-1210  
Typical ZF078-120 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram  
Johnson Controls Unitary Products  
45  
528194-YTG-F-1210  
Typical ZF078-120 Cooling Unit with/without Electric Heat Wiring  
46  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Typical ZF150 Cooling Unit with Gas Heat 230 Volt Wiring Diagram  
Johnson Controls Unitary Products  
47  
528194-YTG-F-1210  
Typical ZF150 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram  
48  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Typical ZF150 Cooling Unit with/without Electric Heat Wiring Diagram  
Johnson Controls Unitary Products  
49  
528194-YTG-F-1210  
Typical ZF078-150 Factory Installed VFD (Option)  
50  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Typical ZF078-150 Factory Installed VFD with Manual Bypass (Option)  
Johnson Controls Unitary Products  
51  
528194-YTG-F-1210  
Typical ZF078-150 Factory Installed VFD with CCS Control (Option)  
52  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Typical ZF078-150 Factory Installed VFD and Manual Bypass with CCS Control (Option)  
Johnson Controls Unitary Products  
53  
528194-YTG-F-1210  
Typical ZF078-150 BAS Ready Unit with Factory Installed VFD (Option)  
54  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Typical ZF078-150 BAS Ready Unit with Factory Installed VFD and Manual Bypass (Option)  
Johnson Controls Unitary Products  
55  
528194-YTG-F-1210  
Typical ZF078-150 VFD Ready Unit (Option)  
56  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
Weights and Dimensions  
ZF078-150 Unit Weights  
Unit 4 Point Load Weight  
Unit 6 Point Load Weight  
FRONT  
D
FRONT  
LEFT  
LEFT  
C
B
C
B
A
A
E
F
D
Y
X
FRONT  
LEFT  
Size  
(Tons)  
078  
(6.5)  
090  
(7.5)  
102  
(8.5)  
120  
Weight (lbs.)  
Shipping Operating  
Center of Gravity  
4 Point Load Location (lbs.)  
6 Point Load Location (lbs.)  
Model  
ZF  
X
Y
A
B
C
D
A
B
C
D
E
F
865  
885  
860  
860  
38  
24  
200  
149  
218  
292  
140  
114  
95  
138  
167  
205  
ZF  
38  
38  
38  
47  
24  
24  
24  
25  
205  
238  
247  
251  
153  
177  
184  
280  
223  
258  
268  
381  
299  
347  
360  
341  
144  
167  
173  
164  
117  
136  
141  
176  
97  
142  
164  
171  
259  
171  
198  
206  
240  
210  
243  
253  
223  
ZF  
1025  
1065  
1258  
1020  
1060  
1253  
113  
117  
190  
ZF  
(10)  
150  
(12.5)  
ZF  
Johnson Controls Unitary Products  
57  
 
528194-YTG-F-1210  
ZF078-150 Unit Accessory Weights  
Unit Accessory  
Weight (lbs.)  
Shipping  
Operating  
Economizer  
Power Exhaust  
90  
40  
49  
110  
30  
85  
35  
49  
110  
30  
Electric Heat1  
Gas Heat2  
Variable Frequency Drive3  
1. Weight given is for the maximum heater size available  
(54KW).  
2. Weight given is for the maximum number of tube heat  
exchangers available (8 tube).  
3. Weight includes mounting hardware, controls and manual  
bypass option (ZF Only).  
ZF078-150 Unit Dimensions  
ZF078 - 120  
29.69  
15.25  
15.38  
59.00  
15.38  
Ø 24.47 TYP. 2 PL.  
B
See detail A for gas inlet  
A
C
D
E
11 3/8  
F
See detail B for drain location  
LEFT  
59  
4 3/16  
FRONT  
89  
21 3/16  
27 5/16  
58  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF150  
29.95  
30.11  
45.64  
14.92  
14.92  
58.09  
14.92  
Ø 24.47 TYP. 4 PL.  
B
See detail A for gas inlet  
A
C
D
E
11 3/8  
F
See detail B for drain location  
LEFT  
4 3/16  
21 3/16  
FRONT  
59  
27 5/16  
89  
ZF078-150 Unit Physical Dimensions  
Unit Model Number  
Dimension (in.)  
C
A
B
D
E
F
078  
090  
102  
120  
150  
42  
42  
50 3/4  
50 3/4  
50 3/4  
89  
89  
89  
89  
119 1/2  
22 1/8  
22 1/8  
30 3/16  
30 3/16  
30 3/16  
18 3/16  
18 3/16  
24 3/16  
24 3/16  
24 3/16  
15 3/16  
15 3/16  
17 3/16  
17 3/16  
17 3/16  
6 3/16  
6 3/16  
6 3/16  
6 3/16  
6 3/16  
Johnson Controls Unitary Products  
59  
528194-YTG-F-1210  
Detail A  
3.184  
3.184  
Gas Pipe Inlet  
Gas Pipe Inlet  
Ø 2.000  
Ø 2.000  
Gas Exhaust Vent  
Gas Exhaust Vent  
Ø 3.126  
Ø 3.126  
17.541  
14.594  
7.715  
7.705  
4.737  
4.727  
42” CABINET  
50 3/4” CABINET  
Detail B  
5-3/8  
3/4” FPT  
ZF078-150 Unit Clearances  
Direction  
Top1  
Distance (in.)  
Direction  
Distance (in.)  
72  
36  
36  
Right  
Left  
Bottom2  
12  
36  
0
Front  
Rear  
1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet.  
2. Units may be installed on combustable floors made from wood or class A, B or C roof covering materials.  
60  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Unit Bottom Duct Openin  
89  
32 11/16  
6 13/16  
6 13/16  
SUPPLY  
AIR  
RETURN  
AIR  
24  
27 1/2  
18  
LEFT  
21  
RIGHT  
20 1/8  
19 1/8  
17 1/8  
12 5/16  
Bottom condensate drain  
14 1/2  
25 9/16  
Bottom gas  
supply entry  
16 3/8  
18 1/16  
FRONT  
TOP VIEW  
Bottom power, control  
and convenience outlet  
wiring entry  
3X Ø 0.875  
Ø 2.469  
Johnson Controls Unitary Products  
61  
528194-YTG-F-1210  
ZF078-150 Unit Electrical Entry  
Disconnect Swith Cover  
Power Entry Ø 2-1/2  
Control Entry Ø 7/8  
Power Entry Ø 2-1/2  
Convenience Outlet Cover  
Convenience Outlet  
Power Entry Ø 7/8  
FRONT  
ZF078-120 Unit Side Duct Openings  
18-1/4  
Dot Plugs  
A
Return  
Air  
Supply Air  
D
B
2-31/32  
5-5/32  
C
31-11/16  
62  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF150 Unit Side Duct Openings  
Dot Plugs  
18-1/4  
A
B
D
5-5/32  
2-7/8  
C
31-5/8  
ZF Side Duct Dimensions  
Dimension (in.)  
Unit Model Number  
A
B
C
D
078  
090  
102  
120  
150  
27 3/4  
27 3/4  
28 1/4  
28 1/4  
28 1/4  
12 1/16  
12 1/16  
18 1/16  
18 1/16  
18 1/16  
27 1/2  
27 1/2  
28 1/4  
28 1/4  
28 1/4  
16  
16  
18 1/4  
18 1/4  
18 1/4  
ZF078-150 Unit Left Duct Opening  
30-3/8  
4-5/16  
Johnson Controls Unitary Products  
63  
528194-YTG-F-1210  
ZF078-150 Unit Accessory Dimensions  
ZF078-150 Roof Curb  
RIGHT  
80-5/8  
20  
INSULATED DECK UNDER  
CONDENSER SECTION  
SUPPLY  
20  
6
RETURN  
2 TYP.  
30  
INSULATED DECK UNDER  
COMPRESSOR SECTION  
50-1/2  
FRONT  
8 or 14  
ZF078-150 Transition Roof Curb  
2 TYP  
4
23  
30-1/2  
50-1/2  
80-5/8  
26  
RETURN  
SUPPLY  
10  
76-5/8  
94  
59-1/4  
64-1/4  
FRONT  
RIGHT  
64  
Johnson Controls Unitary Products  
528194-YTG-F-1210  
ZF078-150 Economizer Assembly  
58 1/4  
88 1/4  
39 1/2  
or  
47 1/2  
Outside Air  
Intake Hood  
35 3/4  
Relief Hood for  
Power Exhaust or  
Barometric Relief  
26  
25 3/4  
26  
30 1/4  
Johnson Controls Unitary Products  
65  
528194-YTG-F-1210  
Economizer Options  
Economizer Usage  
Application  
Bottom Return  
Side Return  
Cabinet Height  
Description  
Model  
All  
All  
Downflow economizer with barometric relief  
Horizontal economizer without barometric relief  
Slab Economizer, 42” tall cabinet  
2EE04705924  
2EE047060241  
2EE047058242  
2EE047057242  
42"  
50"  
ERV or End Return  
Slab Economizer, 50” tall cabinet  
1. Barometric relief must be ordered seperately and installed in duct work.  
2. Barometric relief or fresh air hood not included. Must be ordered seperately.  
Factory Installed Downflow Economizer  
2EE04705924  
2EE04705924  
2EE04705924  
2EE04705924  
Barometric Relief Damper  
2EE04705924  
Barometric Relief Hood  
Fresh Air Hood Fresh Air Damper Return Air Damper  
Field Installed Downflow Economizer W/Power Exhaust  
2EE04705924  
Fresh Air Hood  
2EE04705924  
2EE04705924  
2PE047032XX  
Power Exhaust  
2EE04705924  
Fresh Air Damper Return Air Damper  
2EE04705924  
Barometric Relief Hood  
Barometric Relief Damper  
66  
Johnson Controls Unitary Products  
   
528194-YTG-F-1210  
Field Installed Horizontal Economizer W/Power Exhaust  
2EE04706024  
Return Air Damper  
Field Installed  
Duct Work  
2EE04706024  
Fresh Air Damper  
2PE047032XX  
Power Exhaust  
1EH0408  
Barometric  
Relief Damper  
1EH0408  
Barometric  
Relief Hood  
2EE04706024  
Fresh Air Hood  
Slab Economizer Downflow W/Power Exhaust  
1EH0409  
Fresh Air Hood  
2EE04705X24  
Slab Economizer  
2PE047032XX  
Power Exhaust  
1EH0409 Barometric  
Relief Damper  
1EH0409 Barometric  
Relief Hood  
Johnson Controls Unitary Products  
67  
Slab Economizer End Return W/Power Exhaust  
1EH0409  
Fresh Air Hood  
Field Installed  
Duct Work  
2EE04705X24  
Slab Economizer  
1EH0409  
Barometric Relief Hood  
2PE047032XX  
Power Exhaust  
1EH0409  
Barometric Relief Damper  
Subject to change without notice. Printed in U.S.A.  
Copyright © 2011 by Johnson Controls, Inc. All rights reserved.  
528194-YTG-F-1210  
Supersedes: 528194-YTG-E-0810  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  

Trendnet Automobile Parts Trendnet User Manual
Stinger Power Series 1050 Amp Battery Spv70 User Manual
Sonic Alert Blink Receiver Bl300 User Manual
Soleus Air Ky 36 User Manual
Manual Pex Crimp Tool User Manual
MAKITA HKU01 User Manual
FURRION FACR14SA BL User Manual
FUJITSU GENERAL AUU36RCLX User Manual
CRAFTSMAN 917.377641 User Manual
BLACK DECKER HSVJ520JMBF User Manual