York Air Conditioner 035 09319 User Manual

515.00-O1Y (591)  
035-09319  
®
USER’S  
INFORMATION  
MANUAL  
SPLIT SYSTEM HEAT PUMP  
TROUBLESHOOTING GUIDE  
FAULT  
CODE  
PROBLEM  
CHECK:  
ACTION TO TAKE  
1. Thermostat for proper setting.  
Set thermostat to proper setting.  
Reset circuit breakers - Replace blown fuses.  
Clean coil, see “Coil Care” section.  
Remove snow.  
-
2. Circuit breakers and fuses.  
-
3. Check Outdoor unit for dirty coil. (Cooling)  
4. Outdoor unit for snow accumulation. (Heating)  
5. Indoor unit for dirty filter. (Heating)  
6. Emergency Heat Light Status on thermostat.  
E*FB - Light on = Malfunction  
2
5
2
NO HEAT  
OR  
COOLING  
Clean or Replace, see “Filter Care” section.  
Check 1 thru 5, call qualified service man.  
-
Check 1 thru 5, call qualified service man.  
with Fault Code.  
E*FH - Light flashing = Malfunction  
3,4,7,8,9  
After completing the checks and actions above, turn thermostat to “OFF” for 10 seconds and  
attempt restart. Wait 5 minutes. If system does not start, call qualified serviceman.  
On E*FH models, obtain the fault code number of times the Emergency Heat light on the  
thermostat flashes between pauses.  
sized more closely to the heating needs  
of your home. Heat is supplied at a lower  
temperature over a longer period of time  
to provide a more constant heat, and it  
may give you the impression that your  
system “never stops running".  
CLEARANCES  
SERVICE CALLS  
The minimum clearances shown below  
must be maintained should any patio or  
yard improvements be done around the  
outdoor unit.  
There are a few instances where you  
can avoid unnecessary service calls.  
(See Troubleshooting Guide above).  
For E*FB systems use the guide but  
disregard the Fault Code column. The  
flashing light on the system thermostat  
of E*FH units is capable of providing you  
with time and money saving information.  
The Fault code numbers listed can be  
handled by taking the corrective action  
indicated. Call qualified serviceman if  
displaying fault code numbers not  
listed.  
TOP 48"  
REAR 12"  
SIDES 12"  
FRONT * 24"  
WATER RUN-OFF  
* Service Access Panel  
During the heating cycle, in mild weather  
you may notice water running off the  
outdoor coil. Moisture from the air is  
condensed on the outside surface of the  
coil where it gathers and runs off.  
POWER INTERRUPTION  
When ice, snow, wind storms, etc. dis-  
rupt electrical power supply to your  
house, proceed as follows:  
No need for alarm, your unit has not  
sprung a leak!  
HEATING SEASON  
PARTS INFORMATION  
1. Switch thermostat to Emergency  
Heat. Note: There will be no heat avail-  
able until power is reestablished.  
OUTDOOR COIL  
DEFROSTING  
Replacement parts are available from  
local YORK contractor/dealers or the  
nearest YORK distribution center.  
2. Leave on Emergency Heat for at  
least 8 hours after electrical power is  
reestablished if the power was off more  
than 8 hours.  
At certain outdoor conditions (low tem-  
perature, high humidity), frost may build  
up on the coil of the outdoor unit.  
CHARACTERISTICS  
OF HEAT PUMPS  
3. Switch thermostat back to Heating or  
Auto.  
In order to maintain heating efficiency,  
the system will automatically defrost it-  
self. Steam rising from the outdoor unit  
is normal and is an indication of proper  
operation. The vapor cloud will only last  
for a few minutes. When the defrost  
cycle is completed, the system will auto-  
matically switch back to heating. Electric  
heat is automatically energized to main-  
tain comfort during defrost.  
A CONSTANT HEAT  
COOLING SEASON  
Heat pumps have a noticeably cooler  
supply air temperature than furnaces.  
The common practice of over-sizing fur-  
naces contributes to an “off-and-on-  
again” operation with short blasts of hot  
supply air. The heat pump system is  
1. Switch thermostat to Off position.  
2. Do not switch to Cooling or Auto until  
electrical power has been reestablished  
for 8 hours if the power was off more  
than 8 hours.  
Unitary Products Group  
P.O. Box 1592, York, Pennsylvania USA 17405-1592  
Subject to change without notice. Printed in U.S.A.  
Copyright by York International Corporation 1995. All Rights Reserved.  
515.00-O1Y  
Supersedes: Nothing  
Code: SBY  

York Tcgf24 Thru 60 User Manual
York Stellar Plus E Fh060 User Manual
Sharp Mx B401 User Manual
Samsung Aw0700 User Manual
NEC MULTISYNC EA294WMI User Manual
Lexmark Prestige Pro803 User Manual
EMERSON LIEBERT GXT4 8000RT208 User Manual
DELL XPS 8920 User Manual
ACER E230 User Manual
ACER AW216 User Manual