Marey Tankless Water Heater Installation User Manual

GAS TANKLESS WATER HEATERS  
INSTRUCTIONS MANUAL  
WINTER  
SUMMER  
INVIERNO  
VERANO  
GAS  
WINTER  
SUMMER  
INVIERNO  
VERANO  
GAS  
WINTER  
INVIERNO  
SUMMER  
VERANO  
GAS  
GAS  
WATER/AGUA  
GAS  
WATER/AGUA  
GAS  
WATER/AGUA  
POWER GAS MODEL  
1. Water-controlled automatic ignition:  
Flue duct type  
The water-controlled automatic ignition is provided through a double-ignition high-  
rating device. The flame is sensed by ions. This sensitivity control makes it easy  
and convenient to operate.  
2. Auto cut-off protection:  
The auto-cut-off protection will shut off the gas supply immediately if a flameout  
accidentally occurs, therefore preventing a gas leak.  
Back plate  
3. Energy savings:  
The advanced combustion system comes with a Winter/Summer switch. In winter,  
it strengthens the flame. In summer, it reduces the flame. This provides more  
comfort and energy savings.  
Gas -collecting roof  
Heat exchanger  
4. Low water pressure start-up function:  
When the water pressure is lower than 0.025 Mpa, the unit can still start. This is  
suitable for customers living in high floors or with low water pressure.  
Temperature controller  
5. Anti-freezing protection:  
When the temperature is very low, remove the water discharge valve to discharge  
accumulated water inside the water pipe. This feature prevents damage caused  
by freezing water.  
Main combustor  
Ignition pin I  
Ignition pin II  
Sensor pin  
6. Anti-dry combustion protection:  
Once dry combustion occurs, the protection device will automatically shut off the  
gas supply.  
Gas adjusting valve  
Water-gas interlock  
7. Over-pressure protection:  
When water pressure is over 1.0Mpa, the unit will automatically relieve the  
pressure to avoid damage.  
Water adjusting valve  
Solenoid valve  
Pulse generator  
Microactive switch  
Battery Box  
Sighting Window  
Specification  
Winter/Summer knob  
Instruction  
Gas controlling knob  
Water controlling knob  
Hot water outlet pipe  
Gas inlet pipe  
Water discharge valve  
Water inlet pipe  
Water heater type C/D  
(Drawing 1)  
Sighting Window  
Winter/Summer knob  
Specification  
Instruction  
Gas controlling knob  
Water controlling knob  
(Drawing 1)  
(Drawing 2)  
04  
05  
Forced exhausted type  
Technical parameters:  
Model  
LPG  
NG  
0.4 PSI  
5L/min  
1.3Gal/min  
POWER GAS 5L  
34,614 BTU/h  
79,228 BTU/h  
0.3 PSI  
0.4 PSI  
0.3 PSI  
0.4 PSI  
0.3 PSI  
0.4 PSI  
0.3 PSI  
LPG  
NG  
10L/min  
2.7Gal/min  
POWER GAS 10L  
POWER GAS 16L  
POWER GAS 10L FE  
LPG  
NG  
111,903  
BTU/h  
16L/min  
4.2Gal/min  
Smog-collecting hood  
Wind-pressure valve  
Power wire  
LPG  
NG  
10L/min  
2.7Gal/min  
79,228 BTU/h  
Exhaust Fan  
Heat exchanger  
Ignition pin II  
Electric controller  
1. The water heater must be installed in a well-ventilated area and an exhaust  
pipe must be installed to discharge the exhaust gas. During operation, the water  
heater consumes a lot of oxygen, so the air inlet hole should be made of at least  
0.06 square meters and the exhaust pipe must be installed.  
Main combustion  
Microactive switch  
Sensor pin  
·Poor air circulation and a lack of an exhaust pipe will cause lack of oxygen.  
Carbon monoxide poisoning, death and serious accidents can occur due to  
incomplete combustion.  
Ignition pin II  
Water temperature  
adjusting valve  
Gas adjusting valve  
2. Don´t expose the water heater to strong wind or rain.  
3. Only use the type of gas that is specified on the nameplate.  
4. Gas connections should be done by a professional.  
Solenoid valve  
Water outlet pressure  
Water discharge valve  
Pulse Generator  
5. Don´t use rubber pipes that are aging or cracked.  
Water inlet pipe  
6. The water heater must not be installed near flammable or volatile substances.  
7. The water pressure should not be lower than 0.025Mpa.  
Gas inlet pipe  
8. The water heater shouldn´t be installed above cooking appliances, such as  
ovens or stoves.  
(Drawing 3)  
9. The water heater shouldn´t be installed near stairs nor safety exits (except  
beyond 5m).  
06  
07  
1. Heater Installation  
A) Drill 8mm holes according to the dimensions shown on Drawing 7, and put in  
6mm expansion screws (If the dimensions are different, please use those  
instead).  
B) Hang the water heater and secure it with the expansion screw at the hole in  
the lower bracket. See Drawing 8.  
Exhaust fan  
There must be an air  
inlet and an exhaust outlet  
Washer  
Nut  
Expansion screw  
Heater Case  
Air inlet  
(Drawing 4)  
(Drawing 7)  
2. Pipe Installation  
(Drawing 8)  
A) Connect the cold water inlet pipe.  
Ÿ The cold water inlet joint is G1/2” threaded pipe.  
The water heater must not be  
exposed to strong wind.  
The water heater must not be  
installed outside.  
Ÿ The water inlet pipe should be connected by using flexible metal tube or rigid  
pipe.  
(Drawing 5)  
(Drawing 6)  
Ÿ The inner diameter of the inlet pipe (including the valve) should not be less  
than 8mm.  
Ÿ The cold water valve must be installed with the water inlet pipe.  
Ÿ Please make sure that the filter in the cold water inlet is installed correctly.  
There are always many impurities in the new pipe. Flush them out with water  
before connecting it. After making sure there is no residue in the pipe, install  
the rubber gasket and tighten the water inlet join  
08  
09  
Wind cap  
B) Connecting the hot water outlet pipe.  
Fix bracket  
ŸThe hot water outlet joint is G1/2” threaded pipe.  
Straight pipe  
ŸThe hot water outlet should be connected by flexible metal tube or by rigid pipe.  
Decoration board  
Bend connection  
ŸThe inner diameter of the water outlet pipe (including the valve) shouldn´t be  
less than 8mm.  
C) After installation, fully open the cold water valve to test the flow of water and  
check whether there are any water leaks. Adjust or fix as needed.  
Pipe for connection  
D) Installing the gas supply pipe.  
Water discharge siphon  
Wall  
The gas inlet joint is G1/2” threaded pipe. The gas inlet pipe joint and rubber  
gasket are already attached together. The special soft rubber tube may be used if  
it meets technical specifications.  
Water heater  
NOTE: The gasket must be installed, otherwise, the water heater will burn out.  
Secure it tightly with the pipe clip while connecting it.  
(Drawing 9)  
After the gas inlet is connected, open the gas supply valve and check for gas  
leaks at the joints by using soap water. Adjust or fix as needed.  
C) Make an air inlet door not less than 0.06 square meters at the bottom part of  
the wall.  
Liquefied petroleum gas users should use the high-quality, low pressure adjusting  
valve of with the flux above 0.6m/h.  
D) If the wall is made of flammable material, a clapboard needs to be installed  
between the flue pipe and the wall.  
E) If the flue pipe is connected to a public chimney, the flue pipe section should be  
as short as possible and the joint with the public chimney must not leak at all.  
3. Installing the exhaust pipe.  
A) Following the outline dimensions of the flue pipe as a guide, make a hole with  
the diameter a little larger than the flue pipe at the suitable position to install the  
flue pipe horizontally.  
B) The installation of the flue is shown in Drawing 10. The total height of the  
exhaust pipe should be more than 2.3 meters and the horizontal length should not  
exceed 3 meters. There should be a vertical ascending flue pipe and the hole  
should not be less than 250mm above the exhaust pipe cover. The gap between  
the flue pipe and the hole should not be filled with cement; otherwise any repairs  
would be difficult.  
10  
11  
1. Operations  
F) During operation, please pay attention to the combustion. If there is abnormal  
combustion, close the gas valve right away and contact the service center or gas  
company for maintenance.  
A) Open the cell box and put in correctly two D cell batteries.  
B) Open both the hot water and cold water valves. Close the water inlet valve  
after you make sure the cold water is flowing out through the water outlet and the  
ignition pins discharge.  
G) When the outdoor temperature is below zero and pipe freezing may occur, the  
remaining water should be discharged after using the heater. Water should be  
discharged in the following manner:  
C) Start the gas supply.  
·Turn off the gas supply valve, turn off the tap water supply valve, turn the water  
temperature adjusting the switch to the low temperature position, turn on the hot  
water supply valve, remove the water discharge valve to discharge the remaining  
water, re-install the water discharge valve.  
D) Open the water inlet valve or outlet valve again and the combustor will ignite  
right away. Hot water should flow out immediately. Sometimes, if there is air in the  
pipe, the combustor may not ignite the first time. So, try two or three times.  
H) The body of the water heater can become very hot during operation, so please  
don´t touch any part of the water heater except for the switches.  
E) All water heaters have a seasonal Summer/Winter switch to meet your water  
temperature needs.  
I) While using the water heater, please pay attention to the initial water flow  
F) If you close the water inlet or the water outlet valve, the water heater will stop  
working. If needed, just re-open the water inlet or outlet valve. Please note that  
the temperature of the hot water flowing out is very high at that moment. Please,  
wait for the temperature to adjust.  
temperature to prevent getting scalded.  
J) Check the gas pipes and hoses regularly. If you find joints that are not tightly  
secured or if there are cracks, you should stop using the heater and perform the  
necessary maintenance.  
G) If you close the water inlet valve or the water outlet valve, the water heater will  
shut off immediately. Then, shut off the main gas supply.  
K) We recommend you use copper pipe to install the heater gas entrance.  
2. Warnings  
A) Don't use the water heater in a sealed room or in a room with poor air  
circulation.  
B) The exhaust pipe must be installed to discharge exhaust gas outside.  
C) During operation, if you find out there is a gas leak, close the gas valve  
immediately. The cause of that should be checked out and the service center or  
gas company should be contacted for repair.  
D) Before going to sleep or leaving the house, shut off the gas supply.  
E) Do not block the exhaust pipe or the air inlet. This can cause incomplete  
combustion and lead to gas poisoning.  
12  
13  
1. Check the gas supply pipe (rubber house) regularly to see if it is in good  
condition. If its aging, cracked, leaking or bent.  
Troubleshooting  
2. Check regularly to see if there are water or gas leaks.  
3. Regularly clean the surface of the water heater to remove dirt or dust with a wet  
cloth, and then use a dry cloth to wipe off moisture. For hard to remove dirt,  
please use a neutral detergent to clean it.  
4. For the plastic parts, printing surfaces and sprayed surfaces, it is not suitable to  
use strong detergent, benzene or gasoline to clean them.  
5. Use a dry cloth to clean on the ignition electrode so as to ensure the ignition  
quality.  
6. Regularly remove and wash the stainless steel filter in the cold water inlet.  
7. During operation, please pay attention to the flame to see if it is normal  
condition. Check the heat exchanger and combustor whether there is dust or dirt  
every half a year. Cleaning should be done by a professional.  
8. Avoid accidents. Don´t modify the water heater by yourself.  
Packing list  
The whole of package of the water heater includes:  
1.Installation kit  
2.Shower Heat  
3.Intructions Manual  
1 set  
1 piece  
1 pieces  
14  
15  
Please visit our website to get to know more about other Marey products.  
Marey Heater offers an excellent Customer Service. If you have any question  
about our product, need information about how to install a unit, about our  
Warranty Services, or if you want to share a suggestion, contact us!  
GAS PORTABLE  
POWER PAK  
SANTON  
AQUAMATIC  
POWER GAS  
MINI MAREY  
1-877-727-0277  
A Toll Free number for all your needs!  
16  
17  

Savin 9027 User Manual
Sanyo N 250aaa User Manual
Samsung Msys 830 User Manual
Samsung Aq24s6gb User Manual
Multiquip Ls600 User Manual
Mitsubishi Electronics Skm28zd S User Manual
MIELE DG 163 User Manual
MAKITA LC1230 03 User Manual
LG GN X312SXGB User Manual
KENWOOD KR V6070 User Manual