LG BEKO LG BKE 7630 NS M User Manual

Air Conditioner  
OWNER'S MANUAL  
MODELS:  
LG-BKE 7630 NS G  
LG-BKE 7630 NS M  
LG-BKE 7630 NS A  
Prior to installation, this air-  
conditioning unit must be  
submitted for approval by the  
utility service which provides  
electricity (EN 61000-2,  
EN 61000-3 Norm).  
IMPORTANT  
• Please read this owner's manual carefully and thoroughly  
before installing and operating your room air conditioner.  
• Please retain this owner's manual for future reference after  
reading it thoroughly.  
Safety Precautions  
Safety Precautions  
To prevent the injury of the user or other people and property damage, the following instructions must be  
followed.  
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified  
by the following indications.  
This symbol indicates the possibility of death or serious injury.  
This symbol indicates the possibility of injury or damage to properties only.  
The meanings of the symbols used in this manual are as shown below.  
Be sure not to do.  
Be sure to follow the instruction.  
Installation  
Always perform grounding.  
Don’t use a power cord, a plug or a loose  
socket which is damaged.  
• Otherwise, it may cause electrical shock.  
• Otherwise, it may cause a fire or electrical shock.  
For installation of the product, always  
contact the service center or a professional  
installation agency.  
Securely attach the electrical part cover to  
the indoor unit and the service panel to the  
outdoor unit.  
• Otherwise, it may cause a fire, electrical shock,  
explosion or injury.  
• If the electrical part cover of the indoor unit and  
the service panel of the outdoor unit are not  
attached securely, it could result in a fire or  
electric shock due to dust, water, etc.  
Owner's Manual  
3
Safety Precautions  
Always install an air leakage  
breaker and a dedicated  
switching board.  
Do not keep or use  
flammable gases or  
combustibles near the air  
conditioner.  
Ensure that an installation  
frame of the outdoor unit is  
not damaged due to use for  
a long time.  
• No installation may cause a fire  
and electrical shock.  
• Otherwise, it may cause a fire  
or the failure of product.  
• It may cause injury or an  
accident.  
x
Thinner  
Wa  
Do not disassemble or  
repair the product  
randomly.  
Do not install the product at  
a place that ther is concern  
of falling down.  
Use caution when  
unpacking and installing.  
• It will cause a fire or electrical  
shock.  
• Otherwise, it may result in  
personal injury.  
• Sharp edges may cause injury.  
Operation  
Do not share the outlet with  
other appliances.  
Do not use the damaged  
power cord.  
Do not modify or extend the  
power cord randomly.  
• It will cause an electric shock or • Otherwise, it may cause a fire  
• Otherwise, it may cause a fire  
or electrical shock.  
a fire due to heat generation.  
or electrical shock.  
Take care so that the power  
cord may not be pulled  
during operation.  
Unplug the unit if strange  
sounds, smell, or smoke  
comes from it.  
Keep the flames away.  
• Otherwise, it may cause a fire  
or electrical shock.  
• Otherwise, it may cause  
electrical shock or a fire.  
• Otherwise, it may cause a fire.  
4
Room Air Conditioner  
Safety Precautions  
Take the power plug out if  
necessary, holding the head  
of the plug and do not touch  
it with wet hands.  
Do not use the power cord  
near the heating tools.  
Do not open the suction  
inlet of the indoor/outdoor  
unit during operation.  
• Otherwise, it may cause a fire  
or electrical shock.  
• Otherwise, it may cause a fire  
and electrical shock.  
• Otherwise, it may electrical  
shock and failure.  
Do not allow water to run  
into electrical parts.  
Hold the plug by the head  
when taking it out.  
Never touch the metal parts  
of the unit when removing  
the filter.  
• Otherwise, it may cause the  
failure of machine or electrical  
shock.  
• It may cause electric shock and  
damage.  
• They are sharp and may cause  
injury.  
Ventilate the room well  
when using this appliance  
together with a stove, etc.  
When cleaning the unit, first  
make sure the power and  
breaker are turned off.  
Turn off the main power  
switch when not using the  
product for a long time.  
• An oxygen shortage may occur. • Otherwise, it may cause  
electrical shock.  
• Otherwise, it may cause the  
failure of product or a fire.  
Do not step on the indoor/outdoor unit and  
do not put anything on it.  
Do not place a heavy object on the power  
cord.  
• It may cause an injury through dropping of the unit • Otherwise, it may cause a fire or electrical shock.  
or falling down.  
Owner's Manual  
5
Safety Precautions  
When the product is submerged into water,  
always contact the service center.  
Take care so that children may not step on  
the outdoor unit.  
• Otherwise, it may cause a fire or electrical shock.  
• Otherwise, children may be seriously injured due  
to falling down.  
Installation  
Install the drain hose to ensure that drain  
can be securely done.  
Install the product so that the noise or hot  
wind from the outdoor unit may not cause  
any damage to the neighbors.  
• Otherwise, it may cause water leakage.  
• Otherwise, it may cause dispute with the  
neighbors.  
Always inspect gas leakage after the  
installation and repair of product.  
Keep level parallel in installing the product.  
• Otherwise, it may cause the failure of product.  
• Otherwise, it may cause vibration or water  
leakage.  
6
Room Air Conditioner  
Safety Precautions  
Operation  
Avoid excessive cooling  
and perform ventilation  
sometimes.  
Use a soft cloth to clean. Do  
not use wax, thinner, or a  
strong detergent.  
When gas leaks, open the  
window for ventilation  
before operating the unit.  
• Otherwise, it may do harm to  
your health.  
• The appearance of the air  
conditioner may deteriorate,  
change color, or develop  
surface flaws.  
• Otherwise, it may cause  
explosion, and a fire.  
x
Thinner  
Wa  
Do not use an appliance for  
special purposes such as  
preserving animals  
Do not place obstacles  
around the flow inlet or  
outlet.  
Always insert the filter  
securely. Clean it every two  
weeks.  
vegetables, precision  
machine, or art articles.  
• Otherwise, it may damage your  
properties.  
• Otherwise, it may cause the  
failure of appliance or an  
accident.  
• Operation without the filter will  
cause failure.  
Do not insert the hands or bars through the  
air inlet or outlet during operation.  
Do not drink water coming out of the air  
conditioner.  
• Otherwise, it may cause personal injury.  
• Otherwise, it may cause stomachache.  
Owner's Manual  
7
Prior to Operation  
Prior to Operation  
Preparing for Operation  
1. Contact an installation specialist for installation.  
2. Plug in the power plug properly.  
3. Use a dedicated circuit.  
4. Do not use an extension cord.  
5. Do not start/stop operation by plugging/unplugging the power cord.  
6. If the cord/plug is damaged, replace it with only an authorized replacement part.  
Usage  
1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose  
occupants, pets, or plants to direct airflow for a long time.  
2. Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with  
stoves or other heating devices.  
3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices,  
food, pets, plants, or art objects). Such use may damage your properties.  
Cleaning and Maintenance  
1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.  
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,  
leading to electric shock.  
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a  
very high speed during operation. There is a possibility of injury if the unit’s power is triggered while  
cleaning inner parts of the unit.  
Service  
For repair and maintenance, contact your authorized service dealer.  
8
Room Air Conditioner  
Introduction  
Introduction  
Symbols used in this Manual  
This symbol alerts you to the risk of electric shock.  
This symbol alerts you to hazards that may cause harm to the  
air conditioner.  
This symbol indicates special notes.  
NOTICE  
Features  
WARNING: This appliance should be installed in accordance with national wiring  
regulations. This guide acts as a guide to help to explain product features.  
Indoor  
NANO Plasma Filter  
Signal Receptor  
Front Panel  
Air Filter  
Power Cord  
Air Discharge  
Outdoor  
Air Intake Vents  
Connecting  
Wires  
Piping  
Drain Hose  
Air Outlet Vents  
Base Plate  
Owner's Manual  
9
Electrical Safety  
Electrical Safety  
WARNING: This appliance must be properly grounded.  
To minimize the risk of electric shock, you must alway plug into a grounded oulet.  
Preferred method  
Ensure proper ground  
exists before use  
WARNING: Do not cut or remove the grounding prong from the  
power plug.  
WARNING: Attaching the adapter ground terminal to the wall  
receptacle cover screw does not ground the appliance unless the  
cover screw is metal and not insulated, and the wall receptacle is  
grounded through the house wiring.  
WARNING: If you have any doubt whether the air conditioner is  
properly grounded, have the wall receptacle and circuit checked by  
a qualified electrician.  
10 Room Air Conditioner  
Electrical Safety  
Temporary Use of an Adapter  
We strongly discourage the use of an adapter due to potential safety hazards. For temporary  
connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the  
large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.  
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground  
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal  
damage.  
Temporary method  
Adapter Plug  
Metal Screw  
Receptacle Cover  
WARNING: Never use the appliance with a broken adapter.  
Temporary Use of an Extension Cord  
We strongly discourage the use of an extension cord due to potential safety hazards. For temporary  
situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.  
Owner's Manual 11  
Operating Instructions  
Operating Instructions  
How to insert the Batteries  
1. Remove the battery cover by pulling it according to the arrow  
direction.  
2. Insert new batteries making sure that the (+) and (-) of battery are  
installed correctly.  
3. Reattach the cover by sliding it back into position.  
Use 2 AAA(1.5volt) batteries.  
NOTICE  
Do not use rechargeable batteries.  
Storage and Tips for using the Remote Controller  
The remote controller may be stored by mounting  
it on a wall.  
To operate the room air conditioner, aim the  
remote controller at the signal receptor.  
Signal receptor  
Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.)  
Operation indicating lamps  
On/Off  
: Lights up during the system operation.  
: Lights up during Sleep Mode Auto operation.  
: Lights up during Timer operation.  
Sleep Mode  
Timer  
Defrost Mode  
: Lights up during Defrost Mode or Hot  
Start operation (Heat pump model only)  
: Lights up during outdoor unit operation.  
(Cooling model only)  
Outdoor Unit  
Operation  
Operation indicating  
lamps  
Nano Plasma  
: The function illustrates its dynamic mode by using a multiple lighting system.  
12 Room Air Conditioner  
Operating Instructions  
Remote Control Operations  
The controls will look like the following.  
Controls  
1. START/STOP BUTTON  
Operation starts when this button is pressed  
and stops when the button is pressed again.  
Signal transmitter  
2. OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
3. ROOM TEMPERATURE SETTING  
BUTTONS  
Used to select the room temperature.  
4. INDOOR FAN SPEED SELECTOR  
Used to select fan speed in four steps  
low, medium, high and CHAOS.  
5. JET COOL/HEATING(OPTIONAL)  
Used to start or stop the speed  
5
6
1
3
cooling/heaing.(speed cooling/heating operates  
super high fan speed in cooling/heatig mode.)  
6. CHAOS SWING BUTTON  
Used to stop or start louver movement and  
set the desired up/down airflow direction.  
4
7. ON/OFF TIMER BUTTONS  
Used to set the time of starting and stopping  
operation. (See page 23)  
10  
2
7
CANCEL  
9
ON  
OFF  
SET  
8. TIME SETTING BUTTONS  
Used to adjust the time. (See page 23)  
AUTO CLEAN  
12  
11  
8
17  
14  
9. TIMER SET/CANCEL BUTTON  
Used to set the timer when the desired time  
is obtained and to cancel the Timer  
operation. (See page 23)  
13  
15  
16  
10. SLEEP MODE AUTO BUTTON  
Used to set Sleep Mode Auto operation.  
(See page 23)  
11. AIR CIRCULATION BUTTON  
Used to circulate the room air without  
cooling or heating. (See page 24)  
Flip-up door  
(opened)  
12. ROOM TEMPERATURE CHECKING  
BUTTON  
Used to check the room temperature.  
Operation Mode  
13. NANO PLASMA(OPTIONAL)  
Used to start or stop the  
Cooling Operation  
plasma-purification function. (See page 21)  
14. HORIZONTAL AIRFLOW DIRECTION  
CONTROL BUTTON (OPTIONAL)  
Used to set the desired vertical airflow  
direction.  
Auto Operation or Auto Changeover  
Healthy Dehumidification Operation  
15. RESET BUTTON  
Used prior to resetting time.  
Heating Operation  
16. 2nd F Button  
Used prior to using modes printed in blue  
at the bottom of buttons. (See page 22)  
Cooling Model( ), Heat Pump Model(  
)
17. AUTO CLEAN (OPTIONAL)  
Used to set Auto Clean mode.  
Owner's Manual 13  
Operating Instructions  
Cooling operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door of the remote controller. To select Cooling  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
Cooling  
Auto  
Healthy  
Dehumidification  
Heating  
(Heat pump model only)  
Close the door of the remote controller. Set the temperature  
lower than the room temperature. The temperature can be  
set within a range of 18°C~30°C at intervals of 1°C.  
3
4
ON  
To raise the temperature  
To lower the temperature  
Set the fan speed again with the door  
of the remote controller still closed.  
You can select the fan speed in four  
steps-low, medium, high and CHAOS.  
Each time the button is pressed, the  
fan speed mode is shifted.  
Natural wind by the CHAOS logic  
For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind  
blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.  
14 Room Air Conditioner  
Operating Instructions  
Auto operation (Cooling model only)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door of the remote controller. To select Auto  
Operation, press the operation mode selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
Cooling  
Auto  
Healthy  
Dehumidification  
Heating  
(Heat pump model only)  
The temperature and fan speed are automatically set by the  
electronic controls based on the actual room temperature. If  
you want to change the set temperature, press the Room  
Temperature Setting buttons. The cooler or warmer you feel,  
the more times (up to two times) you should press the button.  
The set temperature will be changed automatically.  
ON  
3
To raise the temperature  
To lower the temperature  
During Auto Operation  
You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.  
If the system is not operating as desired, manually switch to another mode. The system will not  
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling  
mode, it must be done by manually resetting.  
During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and  
down automatically. If you want to stop auto-swing, press the chaos swing button again.  
Owner's Manual 15  
Operating Instructions  
Auto changeover operation(Heat pump model only)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door of the remote controller. To select Auto Changeover  
2
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is shifted in the  
direction of the arrow.  
Auto  
changeover  
Cooling  
Healthy  
Dehumidification  
Heating  
(Heat pump model only)  
Close the door of the remote controller. Set the temperature  
lower than the room temperature. The temperature can be  
set within a range of 18°C~30°C at intervals of 1°C.  
3
4
To raise the temperature  
To lower the temperature  
ON  
Set the fan speed again with the door  
of the remote controller still closed.  
You can select the fan speed in four  
steps-low, medium, high and CHAOS.  
Each time the button is pressed, the  
fan speed mode is shifted.  
During Auto changeover Operation  
The air conditioner changes the operation mode automatically to keep indoor temperature. When room  
temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room  
temperature within ±2°C with respect to setting temperature by auto changeover mode.  
16 Room Air Conditioner  
Operating Instructions  
Healthy dehumidification operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door of the remote controller. To select Healthy  
Dehumidification Operation, press the Operation Mode  
Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
Cooling  
Auto  
Healthy  
Heating  
Dehumidification (Heat pump model only)  
Set the fan speed again with the door  
of the remote controller still closed.  
You can select the fan speed in four  
steps-low, medium, high, or CHAOS.  
Each time the button is pressed, the  
fan speed mode is shifted.  
3
ON  
Natural wind by the CHAOS logic  
For fresher feeling, press the Indoor Fan Speed Selector and set  
to CHAOS mode. In this mode, the wind blows like a natural  
breeze by automatically changing fan speed according to the  
CHAOS logic.  
During Healthy Dehumidification Operation  
If you select the dehumidification mode on the operation selection button, the A/C starts to run the  
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition  
for dehumidification, based on the sensed current room temp.  
In this case, however, the setting temp. is not displayed on the remote controller and you are not able to  
control the room temp. either.  
During the healthy dehumidification function, the airflow volume is automatically set according to the  
optimization algorithm responding to the current room temp. status, so that the room condition is kept  
healthy and comfortable even in the very humid season.  
Owner's Manual 17  
Operating Instructions  
Heating operation (Heat pump model only)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door of the remote controller. To select Heating  
Operation, press the Operation Mode Selection button.  
Each time the button is pressed, the operation mode is  
shifted in the direction of the arrow.  
Heating  
(Heat pump model only)  
Cooling  
Auto  
Healthy  
Dehumidification  
Close the door of the remote controller.  
3
4
Set the temperature higher than the room temperature.  
The temperature can be set within a range of 16°C~30°C at  
intervals of 1°C.  
ON  
To raise the temperature  
To lower the temperature  
Set the fan speed again with the door of the  
remote controller still closed. You can  
select the fan speed in four stepslow,  
medium, high and CHAOS. Each time the  
button is pressed, the fan speed mode is  
shifted.  
Natural wind by the CHAOS logic  
For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the  
wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.  
18 Room Air Conditioner  
Operating Instructions  
Jet cool operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
3
Press the Jet Cool button to operate  
the speed cooling mode and the unit  
will operate at super high fan speed  
on cooling mode for 30 minutes.  
To cancel the Jet Cool mode, press the Jet Cool button, the  
fan speed button or the room temperature setting button  
again and the unit will operate at high fan speed on cooling  
mode.  
or  
or  
NOTICE  
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely  
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to  
cool the room temp. quickly in a hot summer.  
In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL  
function is not available.  
In order to return to the normal cooling mode from the JET COOL mode, just press the operation  
mode selection button, airflow volume selection, temp. setting button or the JET COOL button  
again.  
Owner's Manual 19  
Operating Instructions  
Jet heat operation (Optional)  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
Open the door of the remote controller.  
To select Heating Operation.  
2
3
Cooling  
Auto  
changeover  
Healthy  
Dehumidification  
Heating  
(Heat pump model only)  
Press the Jet Heat button to operate the  
speed heating mode and the unit will  
operate at super high fan speed on heating  
mode for 60 minutes.  
ON  
To cancel the Jet Heat mode, press the Jet Heat button,  
the fan speed button or the room temperature setting  
button again and the unit will operate at high fan speed on  
heating mode.  
4
or  
or  
NOTICE  
During the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely high speed for  
60 minutes setting the room temp. automatically to 30°C. It is especially used to heat the room temp. quickly  
in a cool winter.  
On cooling, healthy dehumidification mode or auto changeover mode, however, the JET HEAT function is not  
available.  
In order to return to the normal heating mode from the JET HEAT mode, just press the operation mode  
selection button, airflow volume selection, temp. setting button or the JET HEAT button again.  
20 Room Air Conditioner  
Operating Instructions  
NANO PLASMA purification operation(Optional)  
Press the Start/Stop button.  
The unit will respond with a  
beep.  
1
Open the door of the remote  
controller. Press the NANO PLASMA  
button.  
2
Operation will start when the button  
is pressed and stop when the button  
is pressed again.  
Set the fan speed again with the door of the remote  
controller closed. You can select the fan speed in four  
steps-low, medium, high or CHAOS.  
Each time the button is pressed, the fan  
speed mode is shifted.  
3
Air purifying operation (NANO PLASMA) can be  
with cooling, Heating or any other operations.  
NANO PLASMA Air Purifying Operation only  
If you press the only NANO PLASMA button,  
only NANO PLASMA purification function  
operates.  
Then, fan speed is low. You can select the fan  
speed in four steps-low, medium, high or  
CHAOS.  
Each time the button (  
speed mode is shifted.  
) is pressed, the fan  
Owner's Manual 21  
Operating Instructions  
2nd F operation  
Press the Start/Stop button.  
The unit will respond with  
a beep.  
1
2
Open the door of the remote control and press the 2nd  
Function button to operate functions printed in blue unter  
buttons.  
(Check the indication of 2nd function on the display of the  
remote controller.)  
These buttons can set the timer as follows:  
SET  
ON  
OFF  
CANCEL  
ON  
OFF  
SET  
AUTO CLEAN  
2nd function disappears in a short time automatically or when  
the button is pressed again.  
3
For more details, refer to functions next pages.  
22 Room Air Conditioner  
Operating Instructions  
Additional Features  
Sleep mode  
1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.  
2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The  
sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode  
Button while aiming at air conditioner.  
3. Make sure the Sleep Mode Auto LED lights up.  
To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star  
(
) disappears from the operation display.  
The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump  
only) for a comfortable sleep.  
NOTICE  
In cooling mode or healthydehumidification mode:  
The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable  
sleep.  
Setting the time  
1. Time can be set only when you press the Reset button. Having replacing the batteries,  
you should press the reset buttons to reset the time. Press the Start/Stop button.  
2. Press 2nd F button and check if 2nd F icon is on.  
3. Press the Time Setting buttons until the desired time is set.  
CANCEL  
4. Press the Timer SET button.  
SET  
Check the indicator for A.M. and P.M.  
NOTICE  
Delay start/Pre-set stop  
1. Make sure the time is set correctly on the display of the remote controller.  
2. Press 2nd F button.  
ON  
OFF  
3. Press the ON/OFF Timer buttons to turn Timer on or off.  
4. Press the Time Setting buttons until the desired time is set.  
CANCEL  
SET  
5. To set the selected time, press the Timer setting button aiming the remote controller at the  
signal receptor.  
To cancel the timer setting  
Check if 2nd F icon is off.  
Press the Timer Cancel button aiming the remote controller at the signal receptor.  
(The timer lamp on the air conditioner and the display will go out.)  
CANCEL  
SET  
Select one of the following four types of operation.  
NOTICE  
with the unit running  
Delay OFF Timer  
Delay ON Timer  
Delay OFF and ON Timer Delay ON and OFF Timer  
Owner's Manual 23  
Operating Instructions  
Airflow direction control  
The up/down and right/left airflow can be adjusted by  
using the remote control.  
Press Chaos Swing button and the louvers will swing.  
Press the button again and the louvers will stop. After  
30 minutes, the louvers return to the maximum airflow  
position automatically.  
Press the Start/Stop button to start the unit.  
Air circulation mode  
Circulates the room air without cooling or heating.  
1. Press the Start/Stop button. the unit will respond with a beep.  
2. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control.  
Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS  
and back to low again.  
CHAOS Air  
Fan speed is on low. Fan speed is on medium. Fan speed is on high.  
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is  
automatically changed from high to low or vice versa, depending on the ambient temperature.  
NOTICE  
Auto clean  
1. Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.  
2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer to  
the below points.  
AUTO CLEAN  
3. When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and  
indoor Fan is started after 20 seconds.  
4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean  
function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more  
Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat  
pump model, for 16 minutes.  
5. If you press the auto clean button again during the product operation , Auto Clean function will be  
cancelled.  
NOTICE  
During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy  
Dehumidification Operation can be removed.  
During Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available.  
24 Room Air Conditioner  
Operating Instructions  
Forced operation  
Operation procedures when the remote control can't be used.  
The operation will be started if the power button is pressed.  
If you want to stop operation, re-press the button.  
Power button  
Heat pump Model  
Cooling Model  
Room Temp. 24°C  
Cooling  
21°C Room Temp. < 24°C  
Healthy Dehumidification  
Room Temp. < 21°C  
Heating  
Operating mode  
Indoor FAN Speed  
Setting Temperature  
Cooling  
High  
High  
High  
High  
22°C  
22°C  
23°C  
24°C  
Test operation  
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room  
temperature and resets in 18 minutes.  
During test operation, if remote controller signal is received, the unit operates as remote controller sets.  
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for  
about 3 seconds.  
If you want to stop the operation, re-press the button.  
Auto restart  
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate  
procedures automatically to the previous operating conditions.  
So there is no need of activating this function by pressing any key or button.  
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.  
As the compressor starts, the fan speed also resumes its previous setting mode.  
Helpful information  
Fan speed and cooling capacity.  
The cooling capacity indicated in the specification is the value  
when the fan speed is set to high, and the capacity will be lower  
at low or medium fan speed.  
High fan speed is recommended when you wish to cool the room  
quickly.  
Owner's Manual 25  
Maintenance and Service  
Maintenance and Service  
Indoor Unit  
WARNING: Turn the system off before cleaning. To clean, wipe with a soft, dry cloth.  
Do not use bleach or abrasives.  
Supply power must be disconnected before cleaning the indoor unit.  
NOTICE  
Air filter  
The air filters behind the front grill should be checked and cleaned once  
every 2 weeks or more often if neccessary.  
1. Lift the front panel. After lifting up the filter tab a bit, take the filter  
out slowly  
Filter  
NOTICE  
Clean the filter after stopping the product.  
2. Clean the filter with a vacuum or warm, soapy water.  
If dirt is conspicuous, wash with a solution of detergent in lukewarm water.  
If hot water (40°C or more) is used, it may be deformed.  
3. After washing with water, dry well in the shade.  
4. Re-install the air filter.  
Filter  
Never use any of the followings:  
Water hotter than 40°C.  
Could cause deformation and/or discoloration.  
Volatile substances  
Could damage the surfaces of the air conditioner.  
Outdoor Unit  
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.  
If clogged with dirt or soot, the heat exchanger  
and panel vents may be professionally steam cleaned.  
Dirty or clogged coils will reduce the  
operating efficiency of the system and cause  
higher operating costs.  
NOTICE  
(Rear)  
(Side)  
Air intake  
vents  
Piping  
Drain Hose  
Air outlet  
vents  
26 Room Air Conditioner  
Maintenance and Service  
Cleaning Filter  
Recomended use period : About 3 months  
1. Lift the front panel, hold it up and pull the Air filter.  
Front Panel  
Air Filter  
2. Remove the Plasma Filter.  
WARNING: Don't touch the PLASMA Filter  
within 10 seconds after opening the inlet  
grille, it may cause electric shock.  
Plasma Purifier  
Filter  
3. Put the Plasma Filter into the neutral detergent for 1~2  
hours and then raise it.  
4. Insert the Plasma Filter after perfectly drying it in shade.  
Now insert Air Filter and close the front panel completely  
by matching the hook.  
Front Panel Hook  
Air Filter  
Hook-Hanger  
Air Filter  
Owner's Manual 27  
Maintenance and Service  
Common Problems and Solutions  
Before calling for service  
If you have problems with your air conditioner, read the following information and try to solve  
the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.  
Air conditioner does not operate  
1. Ensure that the air conditioner is plugged into a proper outlet.  
2. Check the fuse or circuit breaker.  
3. Check whether the voltage is unusually high or low.  
Air does not feel cold enough on the cooling setting  
1. Ensure that the temperature settings are correct.  
2. Check to see if the air filter is clogged with dust. If so, replace the filter.  
3. Ensure that the air flow from the outside is not obstructed and that there is a clearance of  
over 20" between the back of the air conditioner and the wall or fence behind it.  
4. Close all doors and windows and check for any source of heat in the room.  
Before calling for service, please review the following list of common problems and  
solutions.  
The air conditioner is operating normally when:  
You hear a pinging noise. This is caused by water being picked up by the fan on rainy days  
or in highly humid conditions. This feature is designed to help remove moisture in the air  
and improve cooling efficiency.  
You hear the thermostat click. This is caused by the compressor cycle starting and  
stopping.  
You see water dripping from the rear of the unit. Water may be collected in the base pan in  
highly humid conditions or on rainy days. This water overflows and drips from the rear of  
the unit.  
You hear the fan running while the compressor is silent. This is a normal operational  
feature.  
28 Room Air Conditioner  
Maintenance and Service  
Troubleshooting  
The air conditioner may be operating abnormally when:  
Problem  
Possible Causes  
What To Do  
The air conditioner is  
Make sure the air conditioner plug is  
unplugged.  
pushed completely into the outlet.  
The fuse is blown/circuit  
breaker is tripped.  
Check the house fuse/circuit breaker  
box and replace the fuse or reset the  
breaker.  
Air  
conditioner  
does not start  
Power failure.  
If power failure occurs, turn the mode  
control to Off.  
When power is restored, wait 3  
minutes to restart the air conditioner  
to prevent tripping of the compressor  
overload.  
Airflow is restricted.  
Make sure there are no curtains,  
blinds, or furniture blocking the front of  
the air conditioner.  
The thermostat may not be  
set high enough.  
Turn the knob to a higher number.  
The highest setting provides  
maximum cooling.  
The air filter is dirty.  
Clean the filter at least every 2 weeks.  
See the care and Maintenance  
section.  
Air  
The room may have been  
hot.  
When the air conditioner is first turned  
on, you need to allow time for the  
room to cool down.  
conditioner  
does not cool  
as it should  
Cold air is escaping.  
Check for open furnace floor registers  
and cold air returns.  
Cooling coils have iced up.  
See Air Conditioner Freezing Up  
below.  
Air  
Ice blocks the air flow and  
stops the air conditioner from  
cooling the room.  
Set the mode control at High Fan or  
High Cool with thermostat at 1 or 2.  
conditioner  
freezing up  
Owner's Manual 29  

Sharp All In One Printer Ar Cf2 User Manual
Samsung Us18a9 0 Rcfd User Manual
Samsung Kh C Eam User Manual
Samsung Ad24a1 B1 E12 User Manual
Philips Sc479 Dect User Manual
Milwaukee 48 11 1815 User Manual
MAYTAG MVWC450X User Manual
Master Lock B70cea User Manual
CRAFTSMAN 917.258914 User Manual
ACER ASPIRE 3 A315 51 User Manual