Trion Air Boss Dc 128 User Manual

From a Leader in Clean Air Technology  
Trion, a leading global manufacturer and marketer of  
indoor air quality products, designed the worlds first  
air cleaner for the U.S. Navy nuclear submarine fleet  
in 1947. Since then, Trion has continued to provide  
advanced and specialized air cleaning systems for a  
wide range of applications in the commercial and  
industrial markets.  
Air Boss Systems Can Help You:  
Protect employee health  
Boost employee morale  
Comply with government regulations  
Increase product quality  
Enhance company image  
Improve productivity  
Reduce maintenance costs  
Cartridge Air Cleaning  
Dirty Air  
Dirty Air  
Contaminated air is drawn through high-efficiency  
cartridge filters, where the particulate is collected on  
the outside of the media. Filtered air is pulled through  
the system and exhausted. Standard units feature  
Venturi reverse pulse cleaning systems to enhance  
filter life.  
Clean Air  
Applications By Process  
Grinding  
Sanding  
Foundry  
Welding  
Blasting  
Pharmaceutical  
Deburring  
Laser  
Soldering  
Plasma Cutting  
Mixing  
Powder Coating  
Metallizing  
Polishing  
Material Handling  
Milling  
3
TM  
Air Boss Advantages  
High-Performance Cartridges. With a 99% efficiency  
rating for submicron (.5) particulate, extra-large  
circular filters are vertically oriented for uniform dust  
loading and efficient cleaning.  
Efficiency. Many competitors’ products operate  
with a high level of re-entrainment, which means  
that energy and filter life are wasted by repeatedly  
collecting the same dust. Air Boss patented  
downflow/vertical design ensures consistent filtration  
and efficient dust handling from capture to disposal.  
Size Availability. Air Boss is designed with a full  
range of capacities for a vast array of applications.  
From the DC-2 with (2) cartridges to DC-128 with  
(128) cartridges, every Air Boss has the media  
capacity and optimal filtering velocity for every  
type of contaminant and process.  
Powerful Cleaning. The patented venturi-assisted  
design optimizes reverse jet pulse cleaning and  
increases filter life. With four available methods to  
initiate the cleaning cycle, every Air Boss collector  
is equipped with the control system that best fits  
the application.  
Space Economy. The downflow/ vertical design  
has a smaller footprint than comparable units with  
horizontal filters.  
Improved Fan Operation. Venturi and innovative  
cylindrical fan housing increases performance,  
reduces noise, simplifies maintenance and eliminates  
the need for a discharge damper.  
Rock-Solid Construction. Air Boss is built for  
durability and reliability with 11-gauge steel fabrication  
and welded seams/ joints. Air Boss units are designed  
and tested for Seismic Zone 4.  
Easy Maintenance. Outstanding design features  
combine to promote long filter life. Easy access  
allows each filter to be changed in several minutes.  
Dust Collection Efficiency:  
Problem. The #1 challenge to dust collection efficiency is re-entrainment – dust collected is stirred up and has  
to be filtered all over again. The goal is to dislodge the dust and allow it to settle in a hopper below and not  
be redeposited on the filters.  
4
How Downflow/Vertical Systems Operate  
Downflow Inlet  
Cartridge Filters  
Dust Settling Area  
Venturi  
Contaminated air enters the collector above the filter  
cartridges. Specially designed components in the  
cabinet uniformly distribute the contaminated air  
across the top of the filters. The contaminated air  
flows downward without the detrimental velocity  
spikes that are common with competitive designs.  
Dust is conveyed to the settling area below the filters  
by both air movement and gravity. The extremely small  
particulate is collected on the filter media, allowing  
clean air to return to the workplace. Once particulate  
collection is sufficient to reduce airflow, the patented  
reverse jet pulse cleaning system is initiated to  
propel the collected dust off the filters and into the  
settling area.  
Pulse Jets  
Cylindrical Fan Housing  
Downflow  
Venturi  
Air Boss’ downflow/ vertical design has zero velocity  
at the base of each filter stack, allowing dust to  
settle uninhibited below the cartridges, thereby  
eliminating re-entrainment.  
Venturi Reverse Pulse Cleaning is the quick release of  
pressure through a blowtube into a venturi enductor  
tube into a cartridge filter. A higher volume of air is  
induced via this principle. The resulting burst of com-  
pressed air is more equally dispersed across the filter  
resulting in greater cleaning effectiveness compared to  
standard reverse pulse cleaning.  
Cartridge Filters  
The standard 100% cellulose cartridge media is  
high in resin content for mechanical resilience and  
has pleat-lock construction. Standard cartridges are  
rated for temperatures up to 160° F – high temperature  
cartiridges are available.  
Pulse Jets  
Pulse jet performance and economy are maximized by  
optimizing the orifice size and position. There are four  
methods of initiating jet pulse cleaning to best fit the  
end users needs.  
Dust Settling  
The Air Boss design allows larger dust contaminants  
to have a clear path to the settling area and finer dust  
to be collected by the filters.  
Cylindrical Fan Housing  
The motor, fan and full-length venturi are packaged  
into a tubular centrifugal fan arrangement for  
greater performance, quieter operation and  
simplified maintenance.  
Solution. With Air Boss’ patented downflow/ vertical airflow technology, re-entrainment and its effects have been  
minimized for maximum efficiency and filter life. Carefully managed inlet velocity ensures that the air only flows  
downward, never up or sideways. This prevents air movement below the cartridges, where the dust has settled,  
and facilitates effective cleaning, both when the collector is operating and when it is shut down.  
5
FEATURES  
BENEFITS  
Cartridges arranged in vertical  
orientation  
Structural integrity of filter is maintained  
Ensures consistent air-to-cloth ratio for each filter  
Patented downflow/ vertical airflow  
Ensures uniform loading of filters while  
minimizing abrasion  
Process air assists cleaning action during  
online pulsing  
No-flow area below filters acts as settling  
chamber for dusts  
Eliminates 90° filter rotation and 22% to 25% filter  
area loss inherent with horizontal filters  
Small, solid-welded tube sheet below  
vertical cartridge  
Gasket seals enhanced as filters load and cartridge  
becomes heavier  
Eliminates potential for metal distortion and  
possible leakage  
Reduces potential for leakage  
Solid welded construction separating  
clean air and dirty air plenums  
Venturi-assisted to optimize cleaning effectiveness  
Reverse jet pulse design  
Pulse valve silencers  
Reduces overall system dBA  
Standard vs. competitors option  
Programmable Smart Boss  
pulse control with digital pressure  
differential sensor  
Allows for on and offline initiation of cleaning cycle  
15 digital display functions  
Saves compressed air and increases filter life  
OPTIONS  
BENEFITS  
Side Inlet  
Acts as dropout box for sparks  
Reduces overhead ductwork clearance  
Latches designed to release, eliminating replace-  
ment of expensive membrane panels  
Explosion Vent Door/ Latches  
Centrifugal Partial Width Fan  
Fan Silencer  
Eliminates need for volume outlet damper  
Reduces sound levels to comply  
with OSHA and EPA standards  
6
Standard  
Depth  
Standard  
Height  
Standard  
Width  
Unit  
Weight lbs.  
Sq. Ft.  
Media  
Hoppers  
Trion Model  
Filters  
DC-2  
2
4
32”  
63 3/4”  
32”  
508  
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
3
3
4
4
1,025  
1,598  
1,160  
2,205  
1,888  
1,790  
2,465  
3,395  
4,050  
5,025  
4,880  
5,575  
6,245  
6,980  
7,657  
8,450  
9,495  
10,236  
12,490  
13,960  
44 3/4”  
33”  
130 1/8”  
130 1/8”  
155 1/8”  
160 5/16”  
171 1/4”  
158 1/8”  
171 1/4”  
171 1/4”  
191”  
DC-4M  
DC-4  
1,016  
4
1,016  
44 3/4”  
38 1/4”  
24”  
DC-6M  
DC-6  
6
83 3/4”  
80”  
1,524  
6
1,524  
DC-8  
8
63 3/4”  
83 3/4”  
88 3/4”  
105 25/32”  
105 25/32”  
80 1/4”  
106 1/4”  
122 1/4”  
138 1/4”  
154 1/4”  
170 1/4”  
186 1/4”  
202 1/4”  
244 1/2”  
276 1/2”  
2,032  
33”  
DC-12  
DC-18  
DC-24  
DC-32  
DC-40  
DC-48  
DC-56  
DC-64  
DC-72  
DC-80  
DC-88  
DC-96  
DC-112  
DC-128  
12  
18  
24  
32  
40  
48  
56  
64  
72  
80  
88  
96  
112  
128  
3,048  
33 1/4”  
48 1/4”  
48 1/4”  
64 1/4”  
90 1/4”  
74 1/4”  
74 1/4”  
74 1/4”  
74 1/4”  
74 1/4”  
74 1/4”  
74 1/4”  
80 1/4”  
80 1/4”  
4,572  
6,096  
8,128  
189 1/4”  
203 1/8”  
187 1/2”  
187 1/2”  
192 1/2”  
199 5/16”  
206 1/4”  
199 5/16”  
199 5/16”  
187 1/2”  
192 1/2”  
10,160  
12,192  
14,224  
16,256  
18,288  
20,320  
22,352  
24,384  
28,448  
32,512  
Notes: 1) Models DC-2 thru DC-32 dimensions & weights include standard top mount blowers & top inlets.  
2) Models DC-40 thru DC-128 dimensions & weights do not include ground mount/ remote blowers.  
3) All dimensions & weights include hopper/ leg sets for a 55-gallon drum base.  
7
Headquartered in Sanford, North Carolina  
Leading Technology for Cleaner Exhaust Air Since 1947  
Air Purification Systems  

Samsung Fx1600 User Manual
Samsung Uq09s8ge User Manual
Sanyo Uf652436f User Manual
Sharp Fu Y30eu User Manual
Soleus Air Gm Pac 12e1hp User Manual
Soleus Air Kfthp 18 User Manual
Toshiba E Studio 755 User Manual
Weber Barcode Reader Burner Tube Replacement Instructions User Manual
Xerox Workcentre M118 User Manual
Zenoah G38 User Manual