Contact your local SANYO distributor
for brochures on all other ranges of air
conditioning and heating solutions
GAS DRIVEN VRF
ROOM AIR CONDITIONERS
CO2 ECO HEATING SYSTEM
ELECTRIC VRF
ISO 9001: 2001
Certificate Number: JQ116B
ISO 14001: 2001
Certificate Number: ECOOJ0303-33
Indicates conformation
with EC Directives
ELECTRIC VRF
GAS DRIVEN VRF
Electric VRF
SANYO reserves the right to make any variation in specification to the equipment described or to withdraw or replace products
without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication
are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full
installation details, please contact your SANYO distributor.
COMMERCIAL SPLIT SYSTEMS
ROOM AIR CONDITIONERS
HEATING SOLUTIONS
Rating Conditions
The cooling and heating capacities are based on the following conditions:
Cooling: Indoor temperature 27˚C DB/19˚C WB, Outdoor temperature 35˚C DB/24˚ C WB.
Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB 6˚C WB.
Printed using paper produced from 50% recycled material and 50% from sustainable forestry.
SANYO Air Conditioners. The natural choice.
SANYO Air Conditioners. The natural choice.
ECOi_VRF_V1_2009
Unique SANYO benefits
New PAC2 System Design Software
Designing a system for VRF (ECOi and GHP) and PACi
Commercial Split Systems has never been easier
SANYO-Installation cost saving design
SANYO has identified the importance of ever-increasing
demands for fast and accurate responses to customer requests
in our industry. More and more emphasis is being placed upon
energy-efficiency in our marketplace. The ability to calculate
cooling/heating loads and produce information of actual design
conditions is a major advantage to any architect, consultant,
contractor or end user.
Solenoid Valve Box
Industry’s Smallest – 147mm High
• Brazed connections
• Requires only 1 Fixing for mounting
• No transmission wiring at SVK
• No mains power wiring at SVK
• Comes inclusive with lead connection to indoor unit
SANYO understands the ever-changing and demanding
industry we are in and we are pleased to announce the
launch of the next generation of our system design software
program. The new advanced PAC2 system design software has
been customised to make any selection and design process as
quick and easy as possible. The software features a version of
AC Calc Lite. This allows small building loadings to be accurately
Saves the cost of local isolators and additional electrical
wiring
The new PAC2 system software can be used for all SANYO
ECOi, GHP and PACi systems.
calculated and directly imported into the PAC2 software.
SANYO-Intelligent on site learning
Compressor Road Map Control
The design package utilises system wizards and import tools
to enable both simple and complex systems to be created. In
addition, the system will allow outdoor and indoor units to be
dragged and dropped on an interactive desktop. This allows
users to create everything from realistic floor plans with detailed
piping and wiring schematics to send out with quotations,
through to installation guidance drawings.
Features include:
• AC Calc Lite (included in the package)
• Easy to use system wizards
• Auto piping and wiring features
• Converted duties for conditions and pipework
• Auto CAD (DXF) export
• Measures the average saturated suction temperature from the
fan coil units
• Measures the suction pressure and temperature entering the
outdoor unit
• Detailed wiring and pipework diagram
• Calculates the best combination of compressors to run
• Targets inverter compressor at 30 – 80% (most efficient)
Reduces the running cost of the system
The new PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.
SANYO-Comfort control
Air Discharge Temperature Control
• Available on U indoor ducted units
• Discharge air at below 10°C is uncomfortable and can cause
draughts due to cold air dumping
• Air off temperature can be controlled between 70C - 220C
SANYO Solution
No Control
Guaranteed user comfort
LED 1
Blinking
LED 2
Refrigerant Volume “self check”procedure
Judgment mode
Blinking
ON
ECOi 2 & 3WAY systems have an inbuilt self judgement mode to
indicate the present system refrigerant volume.
Normal
Insufficient gas
Overcharge
ON
Blinking
OFF
OFF
Blinking
From the outdoor unit you can start the self judgement mode,
after completion (approx 30mins) the LED display’s the results.
Judgment not possible
Blinking alternately
It ensures unit efficiency, avoids refrigerant wastage and
assists with F-Gas complince.
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
4
3
ECOi Mini 4-6HP 2 Way Inverter Heat Pump VRF Systems
ECOi 2 Way - features at a glance
SANYO’s policy of product development continues
with the expansion of the ECOi Mini, the 2 pipe
heat pump small VRF system specifically designed
for the European market.
ECOi
2
Way is
a
high-performance heat
pump system with excellent energy-saving
features, designed for creating a comfortable
environment when either heating or cooling
is required.
Offering between 11kW and 16kW cooling capacity in 3 sizes
and up to 9 indoor units connected, the ECOi Mini sets new
standards of performance and flexibility.
• Heat pump systems offer heating or cooling
• Single footprint size for all unit capacities
Utilising R410A and DC inverter technology, SANYO offers
VRF to a new and growing market.
• DC inverter technology combined with R410A for excellent
efficiency
Forming a new key part of the SANYO VRF line up, the ECOi
Mini is compatible with the same indoor units and controls
of the electric and gas powered VRF range.
• System configuration from 8HP to 48HP
• Diversity ratio 50-130%
Features at a glance
• Industry low outdoor unit sound levels: from 54.5dB(A)
• Quiet mode offers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs up to 4.10
• Single phase or three phase power supply
• One AMP start current
Highest COPs - lowest running costs
• DC inverter technology combined with R410A for excellent
efficiency
HP
4
5
6
• Heating capacity to -20°C
EER Cooling
COP Heating
4.06
4.34
3.66
4.10
3.39
3.84
• COP of up to 4.34
• Connectability of 40 indoor units from 24HP upwards
• Units available from 8-16HP as single units
• Diversity ratio 50-130%
Wide operating range
• 150m pipe runs
The operating range for heating operation is to -20°C, the
cooling range is to -10°C. The remote controller temperature
setting offers a range from 16°C to 30°C.
• Cooling operation to -10°C
• Full range of indoor units and control options
• Compact outdoor unit 1230x940x340mm
Extended compressor life
Longer piping means greater installation area
The compressor running time is monitored and optimised
by a microcomputer to ensure that there is no imbalance
in the operation times of compressors on the same
refrigerant circuit.
Reducing the refrigerant volume by reducing piping size has
extended the piping actual length to 150m (175m equivalent
piping length).
Save on piping cost
R410A with low pressure loss enables smaller pipe sizes.
This means reduced piping space, improved workability at
the site and reduced piping material costs.
HP
4
5
6
Model name
Power supply
Cooling capacity
Heating capacity
EER Cooling
SPW-CR365GXH56B/SPW-CR365GXH8B SPW-CR485GXH56B/SPW-CR485GXH8B SPW-CR605GXH56B/SPW-CR605GXH8B
230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz
System difference of
elevation: 50m *1
kW
kW
11.20
12.50
4.06
14.00
16.00
3.66
15.50
17.60
3.39
Extended operating range - better output at lower
temperatures
2
*
COP Heating
4.34
4.10
3.84
Actual length: 150m
The operating range for heating has been extended to
-15°C. The remote controller temperature setting for heating
operation has also been extended from 16°C to 30°C.
Running
amperes
Power input kW
Running
amperes
Power input kW
(Equivalent length: 175m)
A
14.1/4.34
2.76
19.6/6.02
3.83
23.4/7.18
4.57
Cooling
Heating
Electric rating
Difference in elevation
between indoor units: 15m
A
14.7/4.52
2.88
19.9/6.13
3.90
23.4/7.19
4.58
Recommended fuse size (motor
rated)
1ph 3ph
25/16
32/16
Dimensions (H/W/D)
Net weight
Air circulation
mm
kg
m3/min
kg
1,230x940x340
104
100
3.5
*1: 40m if the outdoor unit is below the indoor unit.
*2: Total length of pipe: no more than 300m
Refrigerant amount at shipment
Inches
(mm)
Inches
(mm)
Gas
5/8 (15.88)
3/4 (19.05)
Piping connection
Liquid
3/8 (9.52)
Operating sound normal mode
Operating sound quiet mode
51.0
48.0
52.0
49.0
dB(A)
Higher COPs - lower running costs
Cooling
Heating
-10°C DB +43°C DB
-20°C DB +15°C DB
8
Ambient temperature operating
range
HP
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
Maximum number of indoor units
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
6
9
EER Cooling
COP Heating
3.74
4.10
3.54
4.10
3.50
3.91
3.45
3.91
3.38
3.79
3.63
4.06
3.54
4.06
3.51
3.97
3.49
3.96
3.44
3.88
3.43
3.84
3.41
3.85
3.38
3.79
3.50
4.00
3.47
3.94
3.47
3.89
3.45
3.91
3.42
3.86
3.43
3.83
3.40
3.83
3.38
3.79
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
6
5
ECOi 2 Way Heat Pump VRF Inverter Systems
HP
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
C0705DXHN8 C0905DXHN8 C1155DXHN8 C1305DXHN8 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8
8 C0705DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8
16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8
380/400/415V - 3 phase/50,60Hz
Model
Power supply
Cooling capacity
Heating capacity
EER Cooling
kW
kW
kW
kW
22.40
25.00
3.74
28.00
31.50
3.54
33.50
37.50
3.50
40.00
45.00
3.45
45.00
50.00
3.38
50.40
56.50
3.63
56.00
63.00
3.54
61.50
69.00
3.51
68.00
76.50
3.49
73.00
81.50
3.44
78.50
87.50
3.43
85.00
95.00
3.41
90.00
100.00
3.38
96.00
108.00
3.50
101.00
113.00
3.47
107.00
119.00
3.47
113.00
127.00
3.45
118.00
132.00
3.42
124.00
138.00
3.43
130.00
145.00
3.40
135.00
150.00
3.38
COP Heating
4.05
4.06
3.91
3.91
3.79
4.06
4.06
3.97
3.96
3.88
3.84
3.85
3.79
4.00
3.94
3.89
3.91
3.86
3.83
3.83
3.79
Running
amperes
Power
input
Running
amperes
Power
input
A
10.1/9.6/9.3 13.3/12.7/12.2 16.2/15.4/14.8 20.0/19.0/18.3 23.0/21.8/21.0 23.4/22.3/21.5 26.6/25.4/24.4 29.5/28.1/27 33.3/31.7/30.5
5.99 7.90 9.58 11.60 13.30 13.90 15.80 17.50 19.50
10.4/9.9/9.5 13.1/12.4/12.0 16.2/15.4/14.8 19.9/18.9/18.2 22.8/21.6/20.9 23.5/22.3/21.5 26.2/24.8/24.0 29.3/27.8/26.8 33.0/31.3/30.2
36.3/34.5/33.2 39.2/37.2/35.8 43.0/40.8/39.3 46.0/43.6/42.0 46.6/44.4/42.7 49.6/47.2/45.4 52.5/49.9/48.0 56.3/53.5/51.5 59.3/56.3/54.2 62.2/59.0/56.8 66.0/62.6/60.3 69.0/65.4/63.0
21.20 22.90 24.90 26.60 27.40 29.10 30.80 32.80 34.50 36.20 38.20 39.90
35.9/34.0/32.9 39.0/37.0/35.7 42.7/40.5/39.1 45.6/43.2/41.8 46.1/43.7/42.2 49.0/46.4/44.9 52.1/49.4/47.7 55.8/52.9/51.1 58.7/55.6/53.8 61.8/58.6/56.6 65.5/62.1/60.0 68.4/64.8/62.7
Cooling
kW
A
Electric
rating
Heating
kW
6.17
7.75
32
9.60
11.50
13.20
13.90
15.50
32x2
17.70
20.70
22.60
23.10
26.10
28.00
29.30
31.20
30.60
34.70
34.20
37.10
37.90
42.00
1x40
1x32
1x40
1x32
2x32
1x40
1x32
2x40
Recommended fuse sizes (motor rated)
40
2x40
3x40
1035
Dimensions
Net weight
(H/W/D) mm
kg
1887×890×890 (+60)
295
180
1887×1880×890 (+60)
590
1887×1880×890 (+60)
220+180
1887×2870×890 (+60)
985
245
150
345
540
160+150
640
200+160
640
690
220+220
929
Air circulation
m3/min
160
200
220
160+160
180+160
220+160
200+160+160 220+160+160 220+180+160 220+200+160 220+220+160 220+220+180 220+220+200 220+220+220
Gas
Liquid
Balance
3/4 (19.05)
7/8 (22.22)
1 1/8 (28.58)
1 3/8 (34.92)
1 5/8 (41.27)
Piping
connection
3/8 (9.52)
1/2 (12.7)
5/8 (15.88)
3/4 (19.05)
Inches (mm)
dB(A)
1/4 (6.35)
Operating sound normal
mode
54.5
51.5
55.0
52.0
56.0
53.0
60.0
57.0
61.0
58.0
58.0
55.0
58.5
55.5
61.5
58.5
62.0
59.0
62.5
59.5
63.5
64.0
61.0
62.5
59.5
63.0
60.0
64.5
61.5
65.0
62.0
65.5
62.5
66.0
63.0
Operating sound
quiet mode
60.5
Cooling
Heating
-10°C DB +43°C DB
-20°C DB +15°C DB
Ambient temperature
operating range
Maximum number of indoor units
13
16
19
23
26
29
33
36
40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
System example for ECOi 2 Way
Dimensions of unit combinations (ECOi 2 Way and 3 Way)
Outdoor unit
1880
100
18 to 32 HP
8 to 16 HP
890 (Top plate dimension)
890 (Top plate dimension)
890 (Top plate dimension)
Since all piping is concentrated into one
pipe shaft, you can minimise piping space
and construction labour.
Concentration
SANYO make it possible to link outdoor
units together for a large capacity (48HP)
Connection
790 (Installation hole pitch)
790 (Installation hole pitch)
790 (Installation hole pitch)
200
1780 (Installation hole pitch)
Indoor unit
Indoor unit
If indoor/outdoor units need servicing, a ball valve
(optional) cuts off non-operational units to let other
units stay running.
2870
890 (Top plate dimension)
34 to 48 HP
100
100
890 (Top plate dimension)
890 (Top plate dimension)
System limitations
Maximum number of combined outdoor units
Maximum HP of combined outdoor units
Maximum number of connectable indoor units
Indoor/outdoor unit capacity ratio
3
48HP
40
Addition
50-130%
150m
50(40)m
300m
If your indoor capacity load changes in the future, it’s easy to add
on both indoor and outdoor units using the same piping.
Maximum actual piping length
Maximum level difference (when outdoor unit is lower)
Maximum total piping length in one direction
790 (Installation hole pitch)
200 790 (Installation hole pitch)
200 790 (Installation hole pitch)
(2 Way version illustrated)
2770 (Installation hole pitch)
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
8
7
ECOi 3 Way - features at a glance
Solenoid Valve Kit
ECOi 3 Way is one of the most advanced VRF heat
recovery systems available. Not only offering
high-efficiency and performance for simultaneous
heating and cooling, its sophisticated design makes
installation and maintenance much easier.
Fully-automatic simultaneous Cooling/Heating operation and heat recovery
System Example
•
Any design and layout can be used in
a
single system
• Cooling operation is possible down to an outdoor
temperature of -10°C
• Simultaneous heating and cooling for total control
• Single footprint size for all unit capacities (8-16HP)
Solenoid Valve Kit
ATK-RZP56BG
ATK-RZP160BG
• DC inverter technology combined with R410A for
excellent efficiency
Uptomax.40indoorunits
Way ECOi Multi enables
simultaneous heating and
cooling operation by each
solenoid valve kit.
• System configuration from 8HP to 48HP
• Diversity ratio 50-130%
3
• Sound levels: from 54.5dB(A)
• Quiet mode offers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs to 4.1
[Cooling]
[Heating]
[Heating]
[Stop]
[Cooling]
[Cooling]
Same operation
Liquid pipe
medium-temperature,
medium-pressure liquid pipe
Discharge pipe
high-temperature,
high-pressure gas pipe
Suction pipe
low-temperature,
low-pressure gas pipe
• Provides cooling down to -10°C ambient
• Connectability of 40 indoor units from 24HP upwards
Extended operating range - better output at lower
temperatures
The operating range for heating has been extended to
-20°C. The remote controller temperature setting for heating
operation has also been extended from 16°C to 30°C.
Cooling: -10˚C DB ~ 43˚C DB
Heating: -20˚C WB ~ 15˚C WB
8HP ~ 48HP
Solenoid Valve Kit
Up to 5 indoor units with individual remote control
can be connected off 1 SVK box.
Box dimensions: L 166mm X 147mm X 217mm
There is improved performance at lower ambient conditions
due to SANYO’s unique wrap-around outdoor unit coil design
and active defrost management.
Higher COPs - lower running costs
HP
8
10
12
14
16
18
20
22
24
26
28
3.4
3.8
30
32
34
36
38
40
42
3.4
44
46
48
Timer remote controller
3.78
4.09
3.45
3.95
3.41
3.81
3.45
3.91
3.38
3.79
3.57
4.01
3.46
3.96
3.44
3.88
3.45
3.92
3.41
3.84
3.41
3.85
3.38
3.79
3.45
3.93
3.41
3.88
3.42
3.84
3.42
3.88
3.41
3.81
3.40
3.83
3.38
3.79
EER Cooling
COP Heating
3.84
RCS-TM80BG
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
10
9
ECOi 3 Way Heat Recovery VRF Inverter Systems
HP (Combined systems)
Model
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
C0705DZH8 C0905DZH8 C1155DZH8 C1305DZH8 C1405DZH8 8 C0705DZH8 10 C0905DZH8 10 C0905DZH8
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
Power supply
Cooling capacity
Heating capacity
EER Cooling
380/400/415V - 3phase/50Hz
kW
kW
kW
kW
22.40
25.00
3.78
28.00
31.50
3.45
33.50
37.50
3.41
40.00
45.00
3.45
45.00
50.00
3.38
50.40
56.50
3.57
56.00
63.00
3.46
61.50
69.00
3.44
68.00
76.50
3.45
73.00
81.50
3.41
78.50
87.50
3.40
85.00
95.00
3.41
90.00
100.00
3.38
96.00
108.00
3.45
101.00
113.00
3.41
107.00
119.00
3.42
113.00
127.00
3.42
118.00
132.00
3.40
124.00
138.00
3.41
130.00
145.00
3.40
135.00
150.00
3.38
COP Heating
4.09
3.95
3.81
3.91
3.79
4.01
3.96
3.88
3.92
3.84
3.80
3.85
3.79
3.93
3.88
3.84
3.88
3.84
3.81
3.83
3.79
Running amperes A
10.0/9.5/9.2 13.7/13.0/12.6 16.6/15.7/15.2 20.0/19.0/18.3 23.0/21.8/21.0 23.8/22.6/21.8 27.3/26.0/25.0 30.2/28.7/27.7
5.93 8.12 9.82 11.59 13.31 14.10 16.20 17.90
10.3/9.8/9.4 13.5/12.8/12.3 16.6/15.8/15.2 19.9/18.9/18.2 22.8/21.6/20.9 23.9/22.6/21.8 26.8/25.5/24.6 30.0/28.5/27.5
33.6/31.9/30.8 36.5/34.7/33.5 39.4/37.5/36.1 43.0/40.8/39.4 45.9/43.6/42.1 47.5/45.1/43.5 50.5/48.0/46.3 53.0/51.0/49.0 57.0/54.0/52.0 60.0/57.0/55.0 63.0/60.0/58.0 66.0/63.0/60.0 69.0/65.0/63.0
19.70 21.40 23.10 24.90 26.60 27.80 29.60 31.30 33.00 34.70 36.40 38.20 39.90
33.3/31.6/30.5 36.2/34.4/33.1 39.3/37.3/36.0 42.6/40.5/39.0 45.6/43.3/41.7 46.9/44.6/43.0 49.7/47.2/45.5 53.0/50.0/48.0 56.0/54.0/52.0 59.0/56.0/54.0 63.0/59.0/57.0 65.0/62.0/60.0 68.0/65.0/63.0
Cooling
Heating
Power input kW
Running amperes A
Power input kW
Electric ratings
6.11
7.97
9.84
11.51
13.19
14.10
15.90
17.80
19.50
21.20
23.30
24.70
26.40
27.50
29.10
31.00
32.70
34.40
36.20
37.90
39.60
1x40
1x32
2x32
1x40
1x32
2x40
Recommended fuse sizes (motor rated)
32
40
32x2
2x40
680
3x40
1020
Dimensions
Net weight
Airflow
(H/W/D) mm
kg
1,887x890x890 (+60)
180
1,887x1,880x890 (+60)
1,887x1,880x890 (+60)
180+220
1887x2870x890 (+60)
970
290
160
340
580
160+160
630
160+220
920
m3/min
150
200
220
150+160
160+180
160+200
200+220
220+220
160+160+200 160+160+220 160+180+220 160+200+220 160+220+220 180+220+220 200+220+220 220+220+220
Gas
Discharge
3/4 (19.05)
5/8 (15.88)
7/8 (22.22)
1 1/8 (28.58)
1 3/8 (34.92)
1 5/8 (41.27)
3/4 (19.05)
7/8 (22.22)
1 1/8 (28.58)
1 3/8 (34.92)
Piping connection
Inches (mm)
Liquid
3/8 (9.52)
1/2 (12.7)
5/8 (15.88)
3/4 (19.05)
Balance
3/8 (9.52)
Operating sound normal mode
Operating sound quiet mode
54.5
51.5
55.0
52.0
56.0
53.0
60.0
57.0
61.0
58.0
57.8
54.8
58.0
55.0
58.5
55.5
57.8
54.8
60.1
57.1
60.4
57.4
61.0
58.0
61.5
58.5
60.8
57.8
61.3
58.3
61.5
58.5
62.0
59.0
62.4
59.4
62.6
59.6
63.0
60.0
63.3
60.3
dB(A)
Cooling
Heating
-10°C DB +43°C DB
-20°C DB +15°C DB
Ambient temperature
operating range
Maximum number of indoor units
13
16
19
23
26
29
33
36
40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
ATK-RZP56BG and ATK-RZP160BG
Industry’s smallest changeover boxes - fewer locating
problems
Dimensions ECOi 2 Way and 3 Way (8-16 HP)
The SANYO solenoid valve kit is only 147mm high (without the
removable bracket) and takes its power from the indoor unit,
saving the cost of an additional supply.
• No additional power supply required
• Single mounting fix point
• 2 sizes avaliable (up to 5.6kW and 7.5 to 16kW)
Solenoid Valve Kit
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
12
11
VRF Indoor Unit Range for ECOi and GHP
Self-diagnosing function
Mild dry
Wider operation
Automatic fan operation
Air Sweep
Comfortable auto-flap control
Built-in drain pump
Automatic restart function for power failure
Model size
Capacity
7
9
12
16
18
22
25
36
48
60
76
96
Wireless remote control
Cooling
Heating
Cooling
Heating
2.2
2.5
7,500
8,500
SPW-X075XH
2.8
3.2
9,600
11,000
SPW-X095XH
3.6
4.2
12,000
14,000
SPW-X125XH
4.5
5.0
15,000
17,000
SPW-X165XH
5.6
6.3
19,000
21,000
SPW-X185XH
6.4
7.0
22,000
24,000
7.3
8.0
25,000
27,000
SPW-X255XH
10.6
11.4
36,000
39,000
SPW-X365XH
14.0
16.0
47,800
54,600
SPW-X485XH
16.0
18.0
54,600
61,500
SPW-X605XH
22.4
25.0
76,400
85,300
28.0
31.5
95,500
107,500
kW
Built-in infra red
sensorl
Separately installed
infra red sensor
Functions
Capacity BTU/h
SPW-XDR74GXH56B SPW-XDR94GXH56B SPW-XDR124GXH56B SPW-XDR164GXH56B SPW-XDR184GXH56B
SPW-XDR254GXH56B
Panel
PNR-XD484GHAB
SPW-XDR364GXH56B SPW-XDR484GXH56B SPW-XDR604GXH56B
X Type
•
•
Panel
Panel
Panel
Panel
Panel
Panel
Panel
Panel
Semi-Concealed
Cassette
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
PNR-XD484GHAB
SPW-XM075XH
Panel
PNR-XM185
SPW-XM095XH
Panel
PNR-XM185
SPW-XM125XH
Panel
PNR-XM185
SPW-XM165XH
Panel
PNR-XM185
SPW-XM185XH
Panel
PNR-XM185
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
XM Type
Semi-Concealed
SPW-US075XH
SPW-US095XH
SPW-US125XH
SPW-US165XH
SPW-US185XH
US Type
Concealed Duct
SPW-U075XH
SPW-UR74GXH56B
SPW-U095XH
SPW-U125XH
SPW-U165XH
SPW-U185XH
SPW-U255XH
SPW-U365XH
SPW-U485XH
SPW-U605XH
SPW-UR94GXH56B SPW-UR124GXH56B SPW-UR164GXH56B SPW-UR184GXH56B
SPW-UR254GXH56B
SPW-UR364GXH56B SPW-UR484GXH56B SPW-UR604GXH56B
U Type
Concealed Duct
25,48 type
SPW-DR364GX-
SPW-DR484GX-
DR Type
Concealed
Duct
SPW-DR254GXH56B
SPW-DR764GXH56B SPW-DR964GXH56B
H56B
H56B
76,96 type
SPW-K075XH
SPW-K095XH
SPW-K125XH
SPW-T125XH
•
•
•
•
K Type
Wall Mounted Unit
SPW-KR164GXH56B SPW-KR184GXH56B
SPW-KR254GXH56B
KR Type
Wall Mounted Unit
SPW-T165XH
SPW-T185XH
SPW-T225XH
SPW-TDR254GXH56B
SPW-T365XH
SPW-TDR364GXH56B SPW-TDR484GXH56B
SPW-T485XH
SPW-TDR124GXH56B SPW-TDR164GXH56B SPW-TDR184GXH56B
T Type Ceiling-
Mounted Unit
FTR Type
Floor/Ceiling
Mounted Units
SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B
SPW-FUR74EXH56B SPW-FUR94EXH56B SPW-FUR124EXH56B SPW-FUR164EXH56B SPW-FUR184EXH56B SPW-FUR224EXH56B
FUR Type
Floor/Ceiling
Slim Concealed Duct
SPW-FR74GXH56B
SPW-FR94GXH56B
SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B
SPW-FR254GXH56B
SPW-FMR254GXH56B
FR Type Floor
Standing Unit
FMR Type
Concealed Floor
Standing Unit
SPW-FMR74GXH56B SPW-FMR94GXH56B SPW-FMR124GXH56B SPW-FMR164GXH56B SPW-FMR184GXH56B
SPW-ADR74GXH56B SPW-ADR94GXH56B SPW-ADR124GXH56B
Panel
PNR-AD124GHB
ADR Type
Semi-Concealed
Cassette 1-Way
Air Discharge
Panel
PNR-AD124GHB
Panel
PNR-AD124GHB
•
•
•
SR Type
SPW-SR74GXH56B
Panel
PNR-S124GHB
SR94GXH56B
Panel
PNR-S124GHB
SR124GXH56B
Panel
PNR-S124GHB
SR164GXH56B,
Panel
PNR-S124GHB
SR184GXH56B
Panel
PNR-S124GHB
SPW-SR254GXH56B
Panel
PNR-S253GHANB
Semi-Concealed
Cassette 2-Way
Air Discharge
SPW-LDR94GXH56B SPW-LDR124GXH56B SPW-LDR164GXH56B SPW-LDR184GXH56B
Panel
PNR-LD254GHAB
SPW-LDR254GXH56B
Panel
PNR-LD254GHAB
LDR Type
Semi-Concealed
Slim Cassette
Panel
PNR-LD254GHAB
Panel
PNR-LD254GHAB
Panel
PNR-LD254GHAB
GU Type
Total Heat
Exchanger
SPW-GU055XH
SPW-GU075XH
SPW-GU105XH
13
14
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Room Control Systems Overview
Centralised Control Systems Overview
A wide variety of control options to meet the requirements of different customers.
Operation system
Individual control systems
Timer operation
Centralised control systems
Simplified charge ratio for each tenant
Operation with various
Only ON/OFF operation from
function from central
central station
Normal
Operation from
each seat
Daily and
Requirements
Simple operation
operation
weekly programme
Personal computer
Touch screen panel
station
(field supply)
External appearance
External appearance
Web
application
Wireless remote
controller
RCS-SH80BG.WLB
RCS-TH80BG.WLB
RCS-BH80AG.WLB
RCS-TRP80BG.WLB
RCS-SH1BGB
Simplified remote
controller
Timer wired
Schedule timer
SHA-TM64AGB
remote controller
System controller
SHA-KC64AGB
ON/OFF controller
SHA-KC16KAGB
Intelligent controller
SHA-KT256EG
Communication adaptor
SHA-KA128AGB
Type, model name
Type, model name
RCS-TM80BG
RCS-KR1EG
Number of indoor units which
can be controlled
64 groups,
1 group, 8 units
1 group, 8 units
1 group, 8 units
Number of indoor units which can be
controlled
64 groups,
16 groups,
64 units x 4 systems,
max. 256 units
2 systems,
max. 64 units
max. 64 units
max. 64 units
max. 128 units
Power supply from the system
controller.
Up to 10 units can be
connected to one system.
Up to 8 units (4 main units + 4
sub units) can be connected
to one system.
Use without remote controller
is impossible.
A communication adaptor
(SHA-KA128AGB) must be
installed for three or more
systems.
When there is no system
controller, connection is
possible to the T10 terminal
of an
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Main unit/sub unit (1 main
unit + 1 sub unit) connection
is possible.
Use without remote controller
is possible.
Maximum 500 indoor units
(128 per communication
adaptor)
Use limitations
Use limitations
indoor unit.
Connectable
indoor unit
4 series indoor unit
4 series indoor unit
4 series indoor unit
4 series indoor unit
Connectable
indoor unit
4 series indoor unit
4 series indoor unit
4 series indoor unit
4 series indoor unit
Function
Function
ON/OFF
-
-
-
-
-
-
•
•
•
•
•
•
•
•
•
ON/OFF
•
•
•
•
•
•
•
•
•
•
Mode setting
Fan speed setting
Mode setting
Fan speed setting
-
-
-
-
*1
*1
*1
Temperature setting
Air flow direction
•
•
•
Temperature setting
Air flow direction
•
•
•
*1
•
*1
•
*1
•
•
•
•
Permit/Prohibit switching
Weekly programme
-
-
-
Permit/Prohibit switching
Weekly programme
•
•
•
•
•
•
•
-
-
•
•
-
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)
15
16
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
GU Type Heat Exchanger
CFR Units
SANYO’s new heat recovery ventilation system allows
total control via a system network whilst modulating the
temperature and humidity of incoming air supply.
The CFR-PHE unit structure is constructed from Aluzink
frame work and galvanised steel with 20 mm thick fire
resistant acoustic insulation, reducing both weight and
sound levels to a minimum. The system is supplied with
ducted spigots which can be positioned either at the front
or side of the unit to ease installation.
• Integration of heat recovery ventilation and DX coil
technology for optimum air temperature control
• The DX coil can be connected to all ECO & GHP
outdoor units
• High efficiency heat exchanger
• Easy to clean filters
• Easy to clean filter
The high efficiency low pressure loss total heat exchanger is
made of specially treated paper to enable the unit to be as
efficient as 76% during normal operation. This allows system to
recover both latent and sensible heat.
• Compact design
• Filter option
• 3 Way: Solenoid valve kit is required for each unit
• 2 Way: RAP kit is required for each unit
Controller Options
Timer remote controller
Installation example
Humidification DX coil
(optional)
Heat exchanger
Wireless remote controller
Simplified remote controller
Exhaust air
Fresh air
Supply air
Return air
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
Indoor unit specifications
Model Name
Indoor unit specifications
Model CFR/ CFR-PHE
SPW-GU055XH
SPW-GU075XH
SPW-GU105XH
33
55
110
175
220
Air circulation (H) m3/h
Power source
500
750
220/230/240V, 1 phase - 50 Hz
8.2 (2.6)*1
1,000
Nominal air flow *
External Static Pressure
Sound Pressure **
Fans
Power in
Absorbed power
Fan speeds
m3/hr
pa
dB(A)
300
45
43
620
55
51
920
65
50
1580
70
53
1850
77
52
UK Cooling
kW
kW
5.3 (1.7)*1
6.5 (2.3)*1
10.7 (3.4)*1
12.6 (4.6)*1
Fresh air load
treatment capacity
UK Heating
UK Cooling
UK Heating
9.8 (3.5)*1
%
%
59
Enthalpy exchange
efficiency
Watts
A
no
184
0.75
340
1.8
294
2.2
700
4.4
3
700
4.8
67
75
5.6
19,000
0.737
0.737
3.2
Temp exchange efficiency
1
kW
BTU/h
kW
kW
Amps
Amps
3.6
12,000
0.532
0.532
2.4
7.3
25,000
0.798
0.798
3.5
Equivalent cooling capacity
Insulation Class
F
Electrical supply
Bioxigen Elements (PHE only)
Number of elements
Electrical supply
Power in
v/ph/htz
230/1/50
Cooling
Power input
Heating
2 X C
2 X F
Cooling
Running current
Heating
v/ph/htz
Watts
230/1/50
8
EU3
2.4
3.2
3.5
8
8
8
8
Type
Sirocco fan
221 (188)
264 (218)
Filter
External static pressure-return air
External static pressure-supply air
Output
Pa
Pa
kW
db(A)
mm
183 (170)
205 (182)
0.28 (4P)x2
135 (88)
176 (137)
Fan motor
Paper Heat Exchanger
Temperature Efficiency heating ***
Temperature Efficiency cooling ****
CFR-PHE
76%
62%
74%
60%
72%
58%
68%
54%
73%
59%
0.35 (4P)x2
Sound pressure level (C/H)
Height
Width
46 (Cooling), 47 (Heating)
47 (Cooling), 48 (Heating)
48 (Cooling), 49 (Heating)
1220
425
1785
1000
450
1903
* Nominal air flow
Dimensions
mm
mm
mm (inches)
mm (inches)
** Sound pressure 1.5 mts from the unit in free field
*** Data referred to -50C 80% RH OAT room condition 200C 50% RH
**** Data referred to 320C 50% RH OAT room condition 260C 50% RH
Depth
Liquid (flare)
Piping connections Gas (flare)
Drain piping
1120
6.35 (1/4)
12.7 (1/2)
VP-25
Connection duct diameter
Net weight
mm
kg
250
300
168
134
153
The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.
17
18
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
|
Mitsubishi Electronics Split Type Heat Pump Air Conditioners Pmfy P06nbmu E User Manual
Oricom 200 User Manual
Panasonic Kx Tm80 W User Manual
Philips Se455c User Manual
Samsung Aw128aa User Manual
Sony 4442237111 User Manual
Stellar Industries Air Conditioner 50 Hz H Da018 076 User Manual
Tekkeon Tekcharge Mp1550 User Manual
Xantrex Technology Freedom Sw 3000 User Manual
York Air Conditioner 66441 Yum D 1011 User Manual