		 Lossnay   
					Models:   
					LGH-15RX4-E,   
					LGH-50RX4-E,   
					LGH-100RX4-E,   
					LGH-25RX4-E,   
					LGH-65RX4-E,   
					LGH-150RX4-E,   
					LGH-35RX4-E   
					LGH-80RX4-E   
					LGH-200RX4-E   
					Operating Instructions   
					(For the user)   
					Please read through these instructions in order to familiarize yourself with the proper and safe procedures for operat-   
					ing the Lossnay.   
					After reading this manual, keep it in an easily accessible and safe place for future reference.   
					Safety precautions   
					The following signs indicate that death or serious injury may be caused by a failure to heed the precautions described below and the resultant   
					mishandling of the product.   
					WARNING   
					G This product must not be disassembled under any circumstances. Only authorized repair technicians are qualified to conduct   
					disassembly and repairs.   
					No   
					disassembly   
					(Failure to heed this warning may result in fire, electrical shock or injury.)   
					If your product needs to be repaired, consult your dealer.   
					G Do not splash water over this product.   
					(Failure to heed this warning may result in fire and/or electrical shock.)   
					Prohibited   
					G If flammable gases should leak, do not turn the Lossnay’s switch on or off.   
					(Failure to heed this warning may cause the electrical contacts to generate sparks which may result in an explosion.)   
					Open windows to ventilate.   
					G Do not poke your fingers or sticks into the air intake and outlet while the product is operating.   
					(Failure to heed this warning may result in injury.)   
					Do not touch   
					G Gloves should be worn when doing the installation and maintenance work.   
					(Failure to heed this warning may result in injury.)   
					G Be sure that the power board circuit breaker is in the OFF position and is securely locked by lock and key before proceeding with   
					Instructions   
					must be   
					followed   
					maintenance work.   
					(Failure to heed this warning may result in electrical shock or injury.)   
					G In the event of trouble (smell of burning, etc.), shut down operation, set the power board circuit breaker to its OFF position and   
					consult your dealer.   
					(Continued operation without remedying the trouble may result in electrical shock, fire, etc.)   
					Names of the parts   
					Models LGH-15 to 100 RX4   
					Models LGH-150 and 200 RX4   
					1 
					Maintenance cover   
					3 
					Lossnay core holder   
					Air supply fan   
					1 
					Maintenance cover   
					3 
					Lossnay core holder   
					2 
					Control box   
					4 
					2 
					Control box   
					4 Air supply fan   
					5 
					Lossnay core   
					5 
					Lossnay core   
					7 
					Air filter   
					7 
					Air filter   
					6 
					Air exhaust fan   
					6 
					Air exhaust fan   
					8 Damper plate   
					8 
					Damper plate   
					1 
				Operation (Continued)   
					1. Reduces cooling load   
					3. Office equipment room cooling   
					If the air outside is cooler than the air inside the building during   
					the cooling season (such as early morning or at night), “By-pass”   
					ventilation will draw in the cooler outside air and reduce the cool-   
					ing load on the system.   
					During cold season, outdoor air can be drawn in and used as is   
					to cool rooms where the temperature has risen due to the use of   
					office equipment.   
					(Only when interlocked with City Multi and Mr. Slim indoor unit)   
					2. Night purge   
					“By-pass” ventilation can be used to release hot air from inside   
					the building that has accumulated in buildings a business district   
					during the hot summer season.   
					Maintenance   
					Velcro   
					Remove all dust and dirt on air filters and Lossnay core(s) at regular   
					intervals in order to prevent a deterioration in the Lossnay functions.   
					Lossnay core   
					Guideline:   
					Clean the air filters once a year.   
					Clean the Lossnay core(s) once two year.   
					Removing the parts   
					1) Maintenance cover   
					Locate and remove the cover fixing screw. Pull back the hinged clip.   
					Open the door and lift off of the hinge brackets.   
					Maintenance covers   
					Maintenance cover   
					Hinge bracket   
					Air filters   
					Cleaning the parts   
					1) Air filters   
					Hinge   
					Hinge   
					Use a vacuum cleaner to remove light dust. To remove stubborn dirt   
					wash in a mild solution of detergent and lukewarm water. (under 40°C)   
					Vacuum cleaner   
					Air filter   
					Hinge bracket   
					Models LGH-150 and 200 RX4   
					Models LGH-15 to 100 RX4   
					2) Lossnay core(s)   
					Take hold of the handle and draw the Lossnay cores out from the   
					main unit.   
					CAUTION   
					• 
					• 
					Never wash the filters in very hot water and never wash   
					them by rubbing them.   
					Model LGH-15 RX4: .................................................. 1 core   
					Models LGH-25 to 100 RX4: ..................................... 2 cores   
					Models LGH-150 and 200 RX4: ................................ 4 cores   
					Do not dry the filters by exposing them to a flame.   
					Lossnay core   
					Handle   
					2) Lossnay core   
					Handle   
					Use a vacuum cleaner to suck up the dust and dirt on the exposed   
					surfaces of the Lossnay cores. Use a soft brush only to clean ex-   
					posed surface areas.   
					Lossnay   
					core   
					Do NOT wash in water.   
					Main unit   
					Lossnay core   
					Models LGH-15 to 100 RX4   
					Models LGH-150 and 200 RX4   
					3) Air filters   
					After pulling out the Lossnay core(s), pull the air filters, located at   
					the bottom left and right of the Lossnay core(s), off the velcro that   
					holds them in place.   
					Corner   
					Vacuum cleaner   
					(with brush attachment)   
					CAUTION   
					• 
					• 
					Do not use the hard nozzle of the vacuum cleaner. It may   
					damage the exposed surfaces of the Lossnay core(s).   
					Models LGH-15 RX4: ................................................ 2 filters   
					Models LGH-25 to 100 RX4: ..................................... 4 filters   
					Models LGH-150 and 200 RX4: ................................ 8 filters   
					Under no circumstances should the Lossnay core(s) be   
					washed in water.   
					3 
				Maintenance (Continued)   
					2. Press the filter button on the remote controller (PZ-41SLB-E) two   
					times in succession.   
					Assembly after maintenance   
					(This clears the Lossnay’s operating time cumulative data.)   
					1. Bearing in mind the following points, assemble the parts following the   
					sequence for their removal in reverse.   
					Relevant button   
					Relevant display items   
					• 
					• 
					Attach the air filters to the magic tape on the Lossnay core(s).   
					Arrange the Lossnay core with the air filter side downward.   
					FILTER   
					FILTER   
					(Press twice)   
					Specifications   
					* 
					The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic   
					chamber.   
					* 
					* 
					* 
					The noise at the air outlets is the values at a 45° angle, 1.5 meters in front of the unit.   
					The above values apply during Lossnay ventilation when the fan speed is set to high speed.   
					The values for 150 and 200 type main unit outlet noise show in the case of 1 supply air duct.   
					After-sales servicing   
					Consult with your dealer about the after-sales services provided for this   
					Lossnay product.   
					If you hear strange sounds, if no air is blown out or if some other   
					trouble occurs, switch off the power and contact your dealer.   
					Consult with your dealer concerning the cost of inspection or   
					repair work.   
					4 
				 |