OWNERS MANUAL For
Platino® Whirlpool Pedicure Spa
Important Information
Serial Number:
Work Order Number:
Installed by:
Installation Date:
The serial number and work order number are located under the seat bottom cushion on the seat
track plate.
Note: Vietnamese and Korean translations available upon request.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 4 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
European Touch - Limited Warranty.........................................................................2
Certificate of Compliance ..........................................................................................3
Important Information ................................................................................................4
Introduction................................................................................................................6
Important Requirements............................................................................................6
Precautions...............................................................................................................6
Health Risk Warning..................................................................................................6
Installation Specifications Summary.........................................................................7
Location and Support................................................................................................7
Important Installation and Utility Information...........................................................8
Dimensional Drawings...............................................................................................9
Pedicure Spa Specifications....................................................................................11
Installing and Removing the Side Panels...............................................................13
Installing the Floor Mounting Brackets...................................................................13
Remote Control Configurations...............................................................................14
Component Reference.............................................................................................15
Pedicure Product Guidelines...................................................................................15
Crystal Clean™ Pipe-Free® Spa - Operating Instructions.......................................16
Crystal Clean™ Pipe-Free® Spa - Cleaning and Disinfecting Procedures..............17
Removing / Replacing Drain Handle........................................................................18
Removing / Replacing Impeller................................................................................18
History and Notes.....................................................................................................19
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 5 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Thank you for selecting EUROPEAN TOUCH, the leading designer, manufacturer, and marketer of pedicure
spas in North America. The Platino® Whirlpool Pedicure Spa (herein referred to as pedicure spa) is an
innovative w hirlpool pedicure spa that has been designed to serve you dependably for many years. Please
take time to thoroughly read this entire manual before installation and use. If you have any problems or have
questions regarding your pedicure spa, please contact EUROPEAN TOUCH’s Technical Support Department
at 1-800-626-6912, Monday through Friday 8 AM to 5 PM CST. After hours calls are recorded and attended to
the next business day.
Important Requirements
(See limited warranty regarding incidental or consequential exclusions – page 2).
Precautions
• Do not stand in the basin of the pedicure spa!
• Excessive water temperature is dangerous and should be checked before use. Maximum
operating water temperature should not exceed 105° F (41° C) and the maximum supply water
temperature should not exceed 150° F (65° C). (Massachusetts State Code: the maximum supply
water temperature should not exceed 130° F (54° C))
• The appliance has a heated surface. Persons insensitive to heat must be careful when using
the appliance.
• Always enter and exit the pedicure spa slowly and carefully.
• Never bring or operate any electrical devices into or near the pedicure spa.
• This pedicure spa has a weight capacity of 250 pounds.
**Note: Always verify maximum temperatures with you local & state codes.
Health Risk Warning
Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use the
pedicure spa at any time. Nail technicians should advise clients to consult their physician before
using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or persistent pain. In
some cases diabetics may experience improved circulation in their feet, but should first consult their
physician prior to receiving a pedicure.
If the client experiences any pain or discomfort discontinue the use of the pedicure spa
immediately.
Your client’s massage and pedicure spa experience should be pleasant and comfortable.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 6 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Specifications Summary
Note: Failure to comply with federal, state or local codes and ordinances will result in warranty being null and
void.
As stated, the pedicure spa installation must comply w ith all plumbing and electrical codes. A licensed
plumber and licensed electrician must complete the applicable connections of the pedicure spa.
Location and Support
Select a level location. The floor structure beneath the pedicure spa must be capable of supporting the
occupied pedicure spa.
For the seat back to fully recline, the pedicure spa base must be mounted 16 inches from the w all as show n
below :
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 7 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Installation and Utility Information
Electrical Service:
110V: 110V, 60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply pow er to the
pedicure spa. (220V if ordered in 220V configuration)
220V: 220V, 50/60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply pow er to the
pedicure spa.
Water Supply:
All plumbing connections must conform to local codes.
Normal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
Maximum operating w ater temperature should not exceed 105° F (41° C) and the maximum supply water
temperature should not exceed 150° F (65° C). (In Massachusetts, the maximum supply water temperature
should not exceed 130° F (54° C)). Adjust your hot water heater accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below .
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
The pedicure spa drain must meet local plumbing codes. Check valve for drain are not provided and
must be installed by a licensed plumber, if required by Local or State codes.
**Note: See local and state codes as to what type of drain connection is required to be made.
Plumbing Connections
Hot
&
Cold supply
fittings contain Neoperl
DW15GF check valves.
See figure 1 for proper
flow direction.
(does not hav e c heck v alve)
Back of Pedicure Spa
Figure 1
Note: Not using the supplied bulkhead fittings will result in NO backflow protection.
Check your Local & State plumbing codes for additional backflow requirements.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with ANSI/ASME
A112.18.3M, A112.18.1M, CSA B125, and NSF 61
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air gap.
Included in the possible range of applications are fittings with hose connected outlets, fittings w ith pullout
spout, hand held show ers, shampoo fittings and deck-mounted fittings. ASME A112.18.3M is now
referenced in ASMEA112.18.1M (Plumbing Fixture Fittings) and CSA B125. Check valves are listed to both
standards w ith the Canadian Standards Association, IAPMO and UL.
AN SI - American National Standards Institute
ASME - American Society of Mechanical Engineers
CSA- Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underwriters Laboratory
TÜV - Technischer Überwachungs-Verein “Technical Watch-Over Association”
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 8 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional Drawings
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 9 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 10 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Pedicure Spa Specifications
*Hot and cold water supply lines required (hot and cold shut offs may be installed under pedicure spa base)
*Drain installation:
References noted on page 9, standard unit comes w ith drain pump.
Overall dimensions without accessories, seat upright: 60"L (152cm) x 44"W (112cm) x 60"H (152cm)*
Overall dimensions, seat upright, both armrests open w\ cup holders exposed:
60”L (152cm) x 44”W (112cm) x 60”H (152cm)
Without accessories, seat collapsed, both arms closed:
(Shipping position): 60”L (152cm) x 32”W (81cm) x 37”H (94cm)*
Maximum area required for full chair and armrest movement:
77”L (196cm) x 44”w (112cm) x 60”H (152cm)*
Shipping dimensions:
Empty weight:
65”L (165cm) x 33”W (84cm) x 65”H (165cm)*
179 lbs. (81kg)*
Shipping weight:
245 lbs. (102kg)*
Capacity of basin:
Whirlpool pump motor:
Will hold up to 6.0 U.S. Gallons; w ater level markings at 5.5 U.S. gallons
110V:
220V:
1/6 HP, 110V, 60Hz (alternate voltages available)
1/6 HP, 220V, 50/60Hz
Seat and back motors:
24V DC Linear Actuators. Spa requires 16” (41 cm) of space betw een pedicure
spa and w allw ith standard actuator
Massage motor:
Power source:
12V AC, Adapter included (alternate voltages available)
110V:
220V:
110V AC, 2.75 Amp, 60 Hz (GFCI Protected)
220V AC, 2.75 Amp, 50/60 Hz (GFCI Protected)
Caution: Pedicure spa must be installed by a licensed electrician and a licensed plumber,
conforming to all local and national electrical codes.
Construction:
Metal Frame w ith Acrylic Fiberglass Shells, self-contained, pre-plumbed
Crystal Clean™ Pipe-Free® water massage system (Pipe-Free pedicure spas): Six 'underfoot' footplate
water massage grooves, no closed loop circulating pipes, 100% fully drained,
and cleanable
Electrical switches:
On/Off sw itch for w hirlpool pump. A single hand-held, low voltage remote control
for massage motors, heat and seat/back position. Hot and Cold w ater supply
lines required.
Compliances:
Complies w ith ASME/ANSI Whirlpool Bathtub Specs ASME/ANSI A112.19 7M-
1995 and A112.19.8M-1995. Backflow Protection Devices for Faucets with Side
Spray: Check valves comply w ith ANSI/ASME A112.18.3M, A112.18.1M, CSA
B125, and TÜV certified.
Electrostatic Limits:
This unit may loose one ore more functions when electrostatic contact discharge
in excess of 4KV gets into accessible conductive part of the unit and can be
restored by resetting the unit.
This unit may loose one ore more functions when power surge in excess of 2KV
is applied to the AC input pow er port and can be restored by resetting the unit.
This unit may loose one ore more functions w hen subjected to fast transient
voltages in excess of 0.5KV at 5 KHz repetition frequency and can not be
restored.
Limited warranty:
One (1) year from date of shipment.
Due to our policy of continuous improvements, all specifications are subject to change without notice.
*Note: All dimensions and weights are approximate
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 11 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Attaching the Seat Back and Seat Bottom Cushion
Your pedicure spa shipped with the seat back already attached to the spa and with the seat bottom
cushion in the spa shipping box. Follow these instructions to connect the seat back and the seat
bottom to the pedicure spa:
Seat Back Attachment
Seat Bottom Attachment
Step 1: The seat bottom cushion will be
located in the spa on top of the spa basin.
Remove the seat bottom cushion from the
spa basin.
Step 1: Remove the hitch and clevis pins
located on the seat back mounting bracket
on the back of the chair.
Step 2: Slide the seat bracket into the black Step 2: With the Chair fully reclined, attach
end on the linear actuator, and line up the
holes.
the seat bottom cushion to the spa,
aligning the seat bottom cushion with the
provided Velcro strips. Ensure that the
rear of the seat bottom cushion is tight
against the seat back.
Step 3: Slide the clevis pin through the holes
and secure by inserting the hitch pin
through the small hole on the clevis pin.
Please make sure that all parts are removed from the box before discarding the box. If any parts are
missing, you must contact EUROPEAN TOUCH within 30 days of the delivery date for replacement at
800-626-6912.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 12 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing and Removing the Side Panels
To install the side panels on your spa follow the instructions below:
Step 1: Slightly lift side panel into
place on spa frame.
Step 3:Make certain that the side
panels lay above the frame at
the top of the basin, as shown
above.
Step 5: Align the thumbscrew
holes located under cushion
skirt, and screw in the
thumbscrew.
Step 2: Align the magnets on the
frame legs with matching
brackets found on the inside of
the side panel. There is one set
on each leg.
Step 4:The side panel should fit
under the lip of the basin, as
shown above.
Step 6: Install the front plate by
aligning the magnets to the
matching brackets and pressing
into place.
To remove side panels: Reverse steps one through six.
Installing the Floor Mounting Brackets
All Platino Spas installed with gravity drain and / or hard piped to hot and cold supply lines
MUST be anchored to the floor.
To install the floor mounting brackets on your spa follow the instructions below:
Step 1: Adjust the leveling feet until you have at least
Step 2: Place the floor mounting brackets on to
leveling feet diagonally from each other. (2
brackets provided)
a ¼” gap.
Step 3:Mark spots to be drilled. Bracket has ½” hole. If mounting to floor, use (2) 3/8” floor lag bolts with
washer – not provided.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 13 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Control Configurations
Roller Massage function
LEDs indicate Roller feature is
activated and amount of time
activated
Recline Seat Back : Tilt backward
or forward
LED indicates Heat is On
Turns Heat On/Off
LEDs indicate Vibration feature is
activated
Move Seat Bottom: Forward or
Backward.
Turns Vibration feature On/Off
LEDs indicate amount of time
Vibration feature activated
Adjusts intensities up or down
Activates wave or pulse
Increase or Decrease Speed
Note: Pressing with finger
nails, rather than the
pads of fingers, can
damage the remote and
will not be covered under
the warranty.
Note: Remote configurations may vary.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 14 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Component Reference
Pipe-Free
Pipe-Free
Inside Basin View
Front View
Pedicure Product Guidelines
Because there are so many different products on the market, it is difficult to list all of the pedicure products that
are safe to use in our pedicure spas. How ever, the follow ing guidelines can be used:
•
It is your responsibility to understand and follow your state’s regulations regarding product cleaning and
disinfecting requirements.
•
•
Do not use any products containing a foaming agent; this w ill cause excessive foam.
It has been determined that products containing non-dissolving abrasives (such as sand and sea salts)
will not harm the internal component structure of your pedicure spa as long as the entire EUROPEAN
TOUCH cleaning requirements are follow ed without deviation.
•
•
Oil based products may be used in your pedicure spa as long as the cleaning requirements are met.
Please use pedicure products and cleaning solutions in accordance with each manufacturer's
directions.
EUROPEAN TOUCH w hirlpool pedicure spas w ill give you many years of service as long as proper
precautions and precise cleaning and operating instructions are follow ed. It is the responsibility of the pedicure
spa user to properly clean the pedicure spa.
If you are experiencing problems cleaning your pedicure spa, please contact the manufacturer of your pedicure
products or EUROPEAN TOUCH Technical Support at 800-626-6912.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 15 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Crystal Clean™ Pipe-Free® Spa - Operating Instructions
Preparing the Pedicure Spa for Operation:
After the pedicure spa is installed and the plumbing and electrical connections are made, clean and disinfect
the basin before initial use. Rinse the basin by using the attached w ater sprayer. Wipe the basin dry with a
clean tow el.
To Operate the Pedicure Spa, Follow These Easy Steps:
Adding Water to the Pedicure Spa Basin:
1. Close the drain by turning the chrome drain handle counter-clockw ise until it stops.
2. Add w ater to the basin by lifting upw ard on the w ater faucet fill handle. Turn the handle in a counter-
clockw ise direction for cold w ater or clockw ise for warm w ater as indicated by the red (hot) and blue
(cold) markings around the handle (CAUTION: hot w ater can burn skin). Continue to add w ater until the
top of the fill line is reached. The fill line is indicated by the w avy (~~~~) line in the basin.
3. Turn the w ater off by pushing the handle dow nward and center.
Operating the Crystal Clean™ Pipe-Free® System:
The Crystal Clean™ Pipe-Free® System eliminates pipes and traditional style jets that can harbor harmful
bacteria w hile at the same time delivering a soothing, quality foot massage. This unique system is driven by
an impeller that pulls w ater through the inlet cover and then forces the water outward through key massage
zones in the footplate. The end result is a soothing massage delivered to all areas of the foot: front, back
and bottom.
To start or stop the w hirlpool, depress the On\Off button w ith finger (not fingernail) (NOTE: An indicator
light on the “Jets” button flashes when the footplate is improperly installed, or the basin contains no
water. As a result, the whirlpool will not function. To fix, simply check that the footplate is securely
fastened or add water to the basin).
Removing Water from the Pedicure Spa Basin:
First, make certain the w hirlpool jets are turned off by pressing the On/Off switch. The impeller motor w ill quit
running w hen in the “Off” position.
Open the drain by turning the drain handle in a clockw ise direction until it stops, the drain plunger w ill open
and drain pump w ill start to operate. The w ater levelw ill low er as water is pumped out of the basin. Turn the
pump off by turning the drain handle in a counter-clockw ise direction once the basin is fully drained (NOTE:
the PDP will automatically shut off after 2-1/2 minutes. We recommend turning off the pump
manually if all water has drained before automatic shut-off).
Warning:
It is extremely important to follow the cleaning instructions located on the following page. Failure to
clean the pedicure spa adequately can result in serious health issues for your clients as well as the
nail technician. Failing to clean your pedicure spa may also cause the pedicure spa to not work
properly. Please consult your local and state codes concerning pedicure chair cleaning for further
requirements. Failure to followlocal and state codes may result in monetary fines.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 16 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Crystal Clean™ Pipe-Free® Spa - Cleaning and Disinfecting Procedures
Please check with your state board for required cleaning and disinfecting procedures.
It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of the
day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good working
condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection. To clean the
pedicure spa, follow these easy steps.
After Each Pedicure:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Loosen the footplate by turning the footplate tee knobs in a counter-clockwise direction. Remove the footplate
from the basin by lifting upward on the inlet cover. (NOTE: Gently press down on the footplate center when
loosening the footplate tee knobs, as this will relieve pressure and help loosen the tee knobs.)
3. Remove all debris from the basin.
4. Clean all the surfaces of the basin and all components, as well as the top and bottom of the footplate and both tee
knobs. Use low-sudsing soap or detergent and a non-abrasive brush. Remove all visible residue from the inside
of the basin and all other components. Clean off sensor on bottom of basin.
5. Rinse the basin with clean water using the sprayer.
6. Disinfect all components, surfaces, basin, top and bottom of footplate, and footplate tee knobs with an EPA-
registered disinfectant, in accordance with your State Board requirements. *EPA disinfectants require ten-
minute contact.
7. Rinse the basin again with clean water using the sprayer.
8. Thoroughly dry the basin and all other components with a clean towel.
9. Replace the footplate and secure by simultaneously turning both footplate tee knobs in a clockwise direction.
(NOTE: When replacing the footplate, carefully align the mounting studs with the mounting holes.
Tighten each knob until snug. Be careful not to over-tighten, as this can damage the tee knobs.)
After Last Pedicure of the Day:
1. Drain water from the pedicure spa by turning the drain handle to the “Open” position.
2. Remove the drain cover as shown on page 18. Remove the impeller as shown on page 18. Remove all debris.
Wash with a low-sudsing soap or detergent using a soft brush. Disinfect the impeller and drain cover as well as
the area behind the drain cover. Replace drain cover and impeller.
3. Next repeat steps two through seven above as in “After Each Pedicure.”
4. After all components are put back into place, fill basin with clean warm water to the fill line.
5. Pour three teaspoons of low-foaming dishwasher crystals, (not gel) and 1 ounce of household bleach for up to
six gallons of water.
Follow your state board requirements as they may differ from the above step.
6. Turn on the whirlpool and let run for ten minutes.
7. Turn the whirlpool off and drain water from the basin.
8. Using the sprayer, rinse off all components, surfaces, and basin.
9. Refill the basin with clean water and turn the whirlpool on. Run for one minute to rinse.
10. Drain water from the basin and turn off the whirlpool.
11. Wipe dry with clean towel.
12. Make a record of the date and time of this cleaning and disinfecting.
Once a Week Overnight Cleaning:
In addition to the daily cleaning, the following cleaning procedures must be done every week:
1. Follow steps one through five above, as in “After the Last Pedicure of the Day.”
2. Turn on the whirlpool and let run for ten minutes.
3. Turn the whirlpool off and let the water sit overnight in the basin (six to ten hours).
4. In the morning, run the whirlpool for five minutes and drain the basin.
5. Rinse the basin with clean water using the sprayer and dry with a clean towel.
6. Make a record of the date and time of this cleaning and disinfecting.
CAUTION: Cleaning products that contain abrasives can damage the pedicure spa. Use ONLY
non-abrasive products to clean the pedicure spa.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 17 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing / Replacing Drain Handle
Tools needed:
Phillips head screwdriv er
Check y our state and local regulations for cleaning procedures. Links to y our state boards can be f ound on our web site, at
www.europeantouch.com. Ref er to the cleaning procedure page headed “Crystal Clean™ Pipe-Free® Spa - Cleaning and Disinf ecting
Procedures,” page 17.
Follow the steps below for cleaning and replacing parts.
Step 1: To remove the chrome Step 2: Picture, with the drain Picture, of drain plunger removed,
drain handle, loosen the set
screw in the slot on the
drain handle and slip off
chrome handle from chrome
handle post.
handle removed, shown for
cleaning reference.
shown
reference.
for
cleaning
Removing / Replacing Impeller
Check your state and local regulations for cleaning procedures. Links to your state boards can be found on our web site,
at www.europeantouch.com. Refer to the cleaning procedure page headed “Crystal Clean™ Pipe-Free® Spa - Cleaning
and Disinfecting Procedures,” page 17, for cleaning recommendations.
Follow the steps below for cleaning and replacing parts.
Step 1: Remove the tee knobs (2) by Step 3: Remove the impeller knob by Step 5: Once parts are clean,
turning counter clockwise.
turning counter clockwise.
complete steps one through four in
reverse order to replace the parts.
Step 2: Lift the footplate to remove.
Step 4: Lift the impeller.
Step 6: Press firmly down on footplate
to
help
seal
while
simultaneously tightening tee
knobs.
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 18 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
History and Notes
Document ID:15080000
Rev: E
Technical Support: 800-626-6912
Page 19 of 20
Download from Www.Somanuals.com. All Manuals Search And Download.
EUROPEAN TOUCH
8301 W. Parkland Court
Milwaukee, WI 53223
Phone Number: 414-357-7016
Toll Free:
Fax:
800-626-6912
414-357-6360
Email: