Tripp Lite Portable Generator 200502023 User Manual

Owner’s Manual  
®
PowerVerter  
RV Series  
(v. 3.0)  
DC-to-AC Inverter/Chargers  
1111 W. 35th Street, Chicago, IL 60609 USA  
Customer Support: (773) 869-1234  
Input  
Output  
Invert:  
12 VDC  
120V, 60 Hz. AC  
12 VDC  
Charge:  
120V, 60 Hz. AC  
Quiet Mobile Power  
Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed for recreational applications. Tripp Lite RV  
Inverter/Chargers are the quiet alternative to generators-with no fumes, fuel or noise to deal with! You get AC electricity anywhere and anytime  
you need it: away from shore power, rolling down the highway, dry camping in majestic back country or overnighting at a non-electric site. Your  
Tripp Lite Inverter/Charger provides your appliances, equipment and electronics with utility- or generator-supplied AC electricity (filtered  
®
through premium ISOBAR surge protection) whenever available. In addition, it automatically powers your craft's 12V system and recharges  
your connected battery bank-doing what traditional converter/chargers do. Whenever power blackouts, brownouts or high voltages occur, your  
Inverter/Charger immediately and automatically switches over to inverting battery output to power connected AC equipment.  
Better for Your Equipment  
Premium Protection Levels  
®
• Built-In ISOBAR Surge Protection  
• Automatic Overload Protection  
Ideal Output for All Loads (including computers)  
• Frequency-Controlled Output  
• Fast Load Switching  
• Balanced Load Sharing*  
Better for Your Batteries  
Better for You  
Faster Battery Recharge  
• High-Amp, 3-Stage Battery Charger (adjustable)  
Critical Battery Protection  
• Battery Charge Conserver (Load Sense)*  
• Battery Temperature Sensing*  
• High-Efficiency DC-to-AC Inversion  
Quiet, Simple, Maintenance-Free Operation  
• Multi-Function Lights & Switches  
• Automatic Generator Starting*  
• Moisture-Resistant Construction†  
Contents  
Specifications/Warranty/Warranty Registration  
2
Mounting  
10  
11  
12  
13  
13  
14  
Safety  
3
Battery Connection  
AC Input/Output Connection  
Service/Maintenance  
Troubleshooting  
Français  
Feature Identification  
Operation  
4
5-6  
6-8  
9
Configuration  
Battery Selection  
* Available on all models except 612 models. Inverter/Chargers are moisture-resistant, not waterproof.  
Copyright © 2005. PowerVerter® is a registered trademark of Tripp Lite. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
SAVE THESE INSTRUCTIONS!  
This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite  
Inverter/Chargers.  
Note: For Marine installations, please replace this page with the page titled "For Marine Applications Only" found in the Owner's Manual Addendum.  
Location Warnings  
• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit  
and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might  
accumulate. Mounting should be in the driest location available.  
• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger  
shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate  
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.  
• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.  
• Do not install near flammable materials, fuel or chemicals.  
Battery Connection Warnings  
• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.  
• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.  
• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be  
installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some  
ventilation to outside air.  
• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.  
• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury  
or property damage could result.  
Equipment Connection Warnings  
Do not use a Tripp Lite RV Inverter/Charger in life support or healthcare applications where a malfunction or failure of a  
Tripp Lite RV Inverter/Charger could cause failure of, or significantly alter the performance of, a life support device or  
medical equipment.  
You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of  
the Inverter/Charger.  
• Corded Models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use  
power adapters that will eliminate the plug’s ground connection.  
Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this  
will damage the device and void your warranty.  
Operation Warnings  
Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.  
• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any  
service work, the battery supply and AC input connection (if any) should therefore be disconnected.  
• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode  
Switch should be in the OFF position. Dangerous arcing may result.  
3R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Feature Identification  
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.  
1
8
Configuration DIP Switches: optimize Inverter/Charger  
operation depending on your application. See Configuration  
section for setting instructions.  
Hardwire AC Input/Output Terminals (not on corded  
models): securely connect the Inverter/Charger to vehicle or  
facility electrical system input and recommended GFI receptacle  
output. See AC Input/Output Connection section for instructions.  
2
Operating Mode Switch: controls Inverter/Charger operation.  
The “AUTO/REMOTE” setting ensures your equipment  
receives constant, uninterrupted AC power. It also enables the  
Inverter/Charger to be remotely monitored and controlled with  
an optional remote module (Tripp Lite model APSRM4, sold  
separately or included with select models). The “CHARGE  
ONLY” setting allows your batteries to return to full charge faster  
by turning the inverter off which halts battery discharging. See  
Operation section for setting instructions.  
9
Resettable Circuit Breaker: protect your Inverter/Charger against  
damage due to overload. See Operation section for resetting  
instructions.  
10 Remote Control Module Connector: allows remote monitoring  
and control with an optional module (Tripp Lite model  
APSRM4, sold separately or included with select models). See  
remote module owner’s manual for connection instructions.  
Battery Charge Conserver (Load Sense) Dial (not on 612  
models): conserves battery power by setting the low-load level  
at which the Inverter/Charger’s inverter automatically shuts off.  
See Configuration section for setting instructions.  
11  
3
“LINE”, “INVERT”, “LOAD” LEDs: intuitive “traffic light”  
signals show whether the Inverter/Charger is operating from AC  
line power or DC battery power. It also warns you if the  
connected equipment load is too high. See Operation section for  
instructions on reading the indicator lights.  
Main Ground Lug: properly grounds the Inverter/Charger to  
vehicle grounding system or to earth ground. See Configuration  
section for instructions.  
12  
13  
4
“BATT VOLT/CHRG CURR” LEDs: these three lights will turn  
ON in several sequences to show two separate operational condi-  
tions depending on the position of the Operating Mode Switch. See  
Operation section for instructions on reading indicator lights.  
Multi-Speed Cooling Fan: quiet, efficient fan prolongs equipment  
service life.  
Hardwire AC Input/Output Cover Plate  
14  
15  
5
6
DC Power Terminals: connect to your battery terminals. See  
Battery Temperature Sensing Connector (not on 612 models):  
prolongs battery life by adjusting charge based on battery tem-  
perature. Use with cable (included on select models). See  
Configuration section for details.  
Battery Connection section for instructions.  
Ground Fault Interrupter (GFI) AC Receptacles (not on  
hardwire models): allow you to connect equipment that would  
normally be plugged into a utility outlet. They feature ground  
fault interrupter switches that trip if there is excessive current  
on the ground safety wire.  
16 Automatic Generator Start Connector (not on 612 models):  
automatically cycles generator based on battery voltage. Use  
with user-supplied cable. See Configuration section for details.  
7
AC Input Cord (not on hardwire models): connects the  
Inverter/Charger to any source of utility- or generator-supplied  
AC power. See AC Input/Output Connection section for instructions.  
10  
13  
4
3
2
1
11  
15  
16  
13  
1*  
4
10  
3
2
11  
15  
16  
Side Mounted,  
Not Shown  
Side Mounted,  
Not Shown  
Side Mounted,  
Not Shown  
Side Mounted,  
Not Shown  
“FOR USE WITH COPPER WIRE ONLY”  
HOT IN  
9
9
6
NEUTRAL IN  
GROUND IN  
GROUND OUT  
HOT OUT  
NEUTRAL OUT  
5
8
14  
5
12**  
7
Front View (Corded Models)  
Front View (Single Input/Output Hardwire Models)  
* 612 models have only one set of DIP Switches. ** Select models include front-mounted ground lug. † Available on all models except 612 models.  
10  
4
3
13  
1
2
11  
15  
16  
9
12  
8
5
12  
Rear View (Single Input/Output Hardwire Models and Select Corded Models)  
Front View (Dual Input/Output Hardwire Models)  
4R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
light will be off when AC power is supplying the load. This light  
will BLINK to alert you if the load is less than the Battery Charge  
Conserver (Load Sense) setting.  
Switch Modes  
After configuring, mounting and connecting your Inverter/Charger,  
you are able to operate it by switching between the following oper-  
ating modes as appropriate to your situation:  
“LOAD” Red LED: This red light will ILLUMI-  
NATE CONTINUOUSLY whenever the inverter is  
functioning and the power demanded by connected  
appliances and equipment exceeds 100% of load  
capacity. The light will BLINK to alert you when the  
inverter shuts down due to a severe overload or overheating. If this  
happens, turn the operating mode switch “OFF”; remove the over-  
load and let the unit cool. You may then turn the operating mode  
switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it  
has adequately cooled. This light will be off when AC power is sup-  
plying the load.  
AUTO/REMOTE: Switch to this mode when you  
need constant, uninterrupted AC power for connected  
appliances and equipment. The Inverter/Charger will  
continue to supply AC power to connected equipment  
and to charge your connected batteries while utility-  
or generator-supplied AC power is present. Since the  
inverter is ON (but in Standby) in this mode, it will automatically  
switch to your battery system to supply AC power to connected  
equipment in the absence of a utility/generator source or in  
over/under voltage situations. “AUTO/REMOTE” also enables an  
optional remote control module (Tripp Lite model APSRM4, sold  
separately or included with select models) to function when con-  
nected to the unit.  
“BATT VOLT/CHRG CURR” LEDs: these three lights will turn  
ON in several sequences to show two separate operational condi-  
tions depending on the position of the Operating Mode Switch.  
CHARGE ONLY: Switch to this mode when you  
If the switch is in the "AUTO/REMOTE" position, the LEDs indi-  
cate the approximate charge level and voltage of your connected  
battery bank and alert you to several fault conditions. See Chart for  
charge and voltage levels.  
are not using connected appliances and equipment in  
order to conserve battery power by disabling the  
inverter. The Inverter/Charger will continue to sup-  
ply AC power to connected equipment and charge  
connected batteries while utility- or generator-supplied AC power is  
present. However, since the inverter is OFF in this mode, it WILL  
NOT supply AC power to connected equipment in the absence of a  
utility/generator source or in over/under voltage situations.  
If the switch is in the "CHARGE ONLY" position, the LEDs indi-  
cate the approximate charge rate of the Inverter/Charger. See Chart  
for charge rates. Note: the charge rates in the chart are expressed as  
percentages of the Inverter/Charger's rated charging amps, which  
vary by model. Refer to the Specifications to determine the charging  
amps of your specific model.  
OFF: Switch to this mode to shut down the  
Inverter/Charger completely, preventing the inverter  
from drawing power from the batteries, and prevent-  
ing utility AC from passing through to connected  
LED Function with Switch in "AUTO/REMOTE" Position  
Approximate Battery Charge Level*  
equipment or charging the batteries. Use this switch  
to automatically reset the unit if it shuts down due to overload or  
overheating. First remove the excessive load or allow the unit to suf-  
ficiently cool (applicable to your situation). Switch to “OFF”, then  
back to “AUTO/REMOTE” or “CHARGE ONLY” as desired. If  
unit fails to reset, remove more load or allow unit to cool further and  
retry. Use an optional remote control module (Tripp Lite model  
APSRM4, sold separately or included with select models) to reset  
unit due to overload and overtemperature.  
LEDs  
Battery Capacity  
(Charging/Discharging)  
91%–Full  
Illuminated  
Green  
1
2
3
4
5
6
7
1
2
3
Green & Yellow  
Yellow  
81%–90%  
61%–80%  
41%–60%  
21%–40%  
1%–20%  
Yellow & Red  
Red  
4
6
5
Indicator Lights  
All three lights off  
Flashing red  
Your Inverter/Charger (as well as an optional Tripp Lite Remote  
Control Module, sold separately or included with select models) is  
equipped with a simple, intuitive, user-friendly set of indicator  
lights. These easily-remembered “traffic light” signals will allow  
you, shortly after first use, to tell at a glance a wide variety of oper-  
ating details.  
0% (Inverter  
shutdown)**  
7
* Charge levels listed are approximate. Actual conditions vary  
depending on battery condition and load. ** Inverter shutdown protects battery against damage  
due to excessive discharge.  
“LINE Green LED”: If the operating mode switch is  
set to “AUTO/REMOTE”, this light will ILLUMI-  
NATE CONTINUOUSLY when your connected  
equipment is receiving continuous AC power sup-  
plied from a utility/generator source.  
Fault Condition  
LEDs  
Fault  
Illuminated  
Condition  
1
2
All three lights  
flash slowly*  
Excessive discharge  
(Inverter shutdown)  
2
1
If the operating mode switch is set to “CHARGE  
All three lights  
flash quickly**  
Overcharge (Charger  
shutdown)  
ONLY”, this light will BLINK to alert you that the unit’s inverter is  
OFF and will NOT supply AC power in the absence of a utility/gen-  
erator source or in over/under voltage situations.  
*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown  
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼  
second off. Charger shutdown protects battery against damage due to overcharge. May also  
indicate a battery charger fault exists. See Troubleshooting section.  
“INV” (Inverting) Yellow LED: This light will  
ILLUMINATE CONTINUOUSLY whenever con-  
nected equipment is receiving battery-supplied,  
inverted AC power (in the absence of a utility/gener-  
ator source or in over/under voltage situations). This  
5R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(continued)  
Operation  
LED Function with Switch in "CHARGE ONLY" Position  
Resetting Your Inverter/Charger to  
Restore AC Power  
Your Inverter/Charger may cease supplying AC power or DC charg-  
ing power in order to protect itself from overload or to protect your  
electrical system. To restore normal functioning:  
Approximate Charge Rate Indication  
LEDs  
Illuminated  
Charge Rate  
Overcharge  
error*  
1
All three lights on  
1
2
3
Overload Reset: Switch operating mode switch to “OFF” and  
remove some of the connected electrical load (ie: turn off some of  
the AC devices drawing power which may have caused the overload  
of the unit). Wait one minute, then switch operating mode switch  
back to either “AUTO/REMOTE” or “CHARGE ONLY.”  
2
3
4
5
6
Red  
75% - 100%  
50% - 75%  
25% - 50%  
0% - 25%  
0%  
Red & Yellow  
Yellow  
4
6
5
Green  
Output Circuit Breaker Reset: Alternatively, check output circuit  
breaker(s) on the unit's front panel. If tripped, remove some of the elec-  
trical load, then wait one minute to allow components to cool before  
resetting the circuit breaker. See Troubleshooting for other possible  
reasons AC output may be absent.  
All three lights off  
* If all three lights remain on, an internal fault may exist. Turn off and disconnect the unit.  
Then, call Tripp Lite at (773) 869-1234 for assistance.  
Configuration  
Set Configuration DIP Switches  
Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation  
depending on your application. RV612UL and RV612ULH models include one set of four DIP Switches. All other models include an additional set  
of four DIP switches to configure additional operational functions. Refer to the appropriate section to review the instructions for your spe-  
cific model.  
B4  
B3 B2  
B1  
A4  
A3 A2  
A1  
INPUT C/B 10A  
Group B Dip Switches (Not on 612 Models)  
Group A Dip Switches (All Models)  
Group A DIP Switches (All Models)  
Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see  
diagram) as follows:  
Select Battery Type—REQUIRED  
Select High AC Input Voltage Point  
for Switching to Battery—OPTIONAL*  
(All Models)  
A2  
A1  
A4 A3 A2 A1  
A4 A3 A2 A1  
(All models)  
CAUTION: The Battery Type DIP Switch setting must  
match the type of batteries you connect, or your batteries  
may be degraded or damaged over an extended period of  
time. See “Battery Selection,” p. 10 for more information.  
Battery Type  
Switch Position  
Up  
Down (factory setting)  
Voltage  
145V  
Switch Position  
Up  
Down (factory setting)  
Gel Cell (Sealed) Battery  
Wet Cell (Vented) Battery  
135V  
* Most of your connected appliances and equipment will perform adequately when your Inverter/Chargers High AC Input Voltage Point (DIP Switch #2 of Group A) is set to 135V and its Low AC Voltage Input Point (DIP Switches #3 and #4 of Group A or DIP Switch #3 for  
612 models) are set to 95V. However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that would have little effect on equipment operation, you may wish to adjust these settings. By increasing the High AC Voltage Point and/or  
decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings.  
6R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(continued)  
Configuration  
All Models Except 612 Models  
612 Models Only  
A4  
A3  
A3  
Settings  
&
A4 A3 A2 A1  
A4 A3 A2 A1  
A4 A3 A2 A1  
A4 A3  
Select Low AC Input Voltage  
Point for Switching to Battery—  
OPTIONAL*  
A4 A3 A2 A1  
Select Low AC Input Point for Switching to  
Battery—OPTIONAL  
Voltage  
105V  
95V  
Switch Position  
Up  
Switch  
Voltage  
Position  
Down (factory setting)  
Set Battery Charging Amps Type—OPTIONAL  
A4  
105V  
95V  
85V  
75V  
#A4 Up & #A3 Up  
High Charge Amp  
Low Charge Amp  
Check specifications on for your unit’s high- and low-charging  
amp options. By setting on high charging, your batteries will  
charge at maximum speed and your RV 12V DC system loads  
will be well-supplied. When setting on low charging, you  
lengthen the life of your batteries (especially smaller ones).  
A4 A3 A2 A1  
#A4 Up & #A3 Down  
#A4 Down & #A3 Up  
#A4 Down & #A3 Down  
(factory setting)  
Battery Charger  
High Charge Amp  
Low Charge Amp  
Switch Position  
Up (factory setting)*  
Down  
A4 A3 A2 A1  
* RV612ULH models have the “A4” DIP Switch set in the up position (high charge  
amps). RV612UL models have the “A4” DIP Switch set in the down position (low  
charge amps).  
* Most of your connected appliances and equipment will perform adequately when your Inverter/Chargers High AC Input Voltage Point (DIP Switch #2 of Group A) is set to 135V and its Low AC Voltage Input Point (DIP Switches #3 and #4 of Group A or DIP Switch #3 for  
612 models) are set to 95V. However, if the unit frequently switches to battery power due to momentary high/low line voltage swings that would have little effect on equipment operation, you may wish to adjust these settings. By increasing the High AC Voltage Point and/or  
decreasing the Low AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings.  
Group B DIP Switches (Not on 612 Models)  
B1 B2  
Select Load Sharing—OPTIONAL (Not on 612 Models)  
Your Inverter/Charger features a high-output battery charger that can draw a significant amount of AC power from your utility source or  
generator when charging at its maximum rate. If your unit is supplying its full AC power rating to its connected heavy electrical loads at the  
same time as this high charging occurs, the AC input circuit breaker could trip, resulting in the complete shut off of pass-through utility power.  
To reduce the chance of tripping this breaker, all RV Inverter/Chargers (except models RV612UL and RV612ULH) may be set to automatically limit  
the charger output. This keeps the sum of the unit’s AC load and charge power within the circuit breaker rating. This charger-limiting func-  
tion has four settings, allowing you to reduce the charger’s draw lower and lower, as needed, if the AC input circuit breaker keeps tripping  
under the normal AC loads of devices you have connected downline from the unit. The figures show how to set your DIP Switches to deter-  
mine how heavy the connected load can be on your Inverter/Charger before charger-limiting begins.  
All Models, except RV612UL & RV612ULH*  
Select Battery Charger-Limiting Points—OPTIONAL  
All Models, except RV612UL, RV612ULH & RV1012UL*  
“Least Limiting” (#B2 Down & #B1 Up,  
B4 B3 B2 B1  
(Not on 612 Models)  
factory setting for all models except  
RV1012UL): Charger-limiting begins  
when the Inverter/Charger’s load reaches  
66% of the Inverter/Charger’s load rating.  
Charger output falls gradually from full output at 66% of the  
Inverter/Charger’s load rating to about 40% of full output at full  
load.  
“Most Limiting” (#B2 & #B1 Up):  
B4 B3 B2 B1  
Charger-limiting takes effect the moment  
any 120V AC load is applied; charger out-  
put falls gradually from full output at no  
120V load passing through to no output at  
full load.  
“No Limiting” (#B2 & #B1 Down): No  
B4 B3 B2 B1  
“Less Limiting” (#B2 Up & #B1 Down,  
factory setting for RV1012UL models):  
Charger-limiting begins when the  
Inverter/Charger’s load reaches 33% of the  
Inverter/Charger’s load rating. Charger  
B4 B3 B2 B1  
charger-limiting occurs at any load size.  
output falls gradually from full output at 33% of the  
Inverter/Charger’s load rating to about 40% of full output at full load.  
* NOTE! RV612UL & RV612ULH models do not include these DIP Switches. There are only two limiting points available for RV1012UL models—"Most Limiting" and "Less Limiting"—which  
are determined solely by the position of the B1 DIP Switch (either up or down). The B2 DIP Switch on these models has no effect.  
7R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(continued)  
Configuration  
Select Equalize Battery Charge—OPTIONAL  
Setting Procedure  
B3  
(Not on 612 Models)  
• Move to “Equalize” (DOWN) position for three seconds.  
This DIP Switch is momentarily engaged  
to begin the process of equalizing the  
charge state of your battery’s cells by time-  
limited overcharge of all cells. This can  
extend the useful life of certain types of  
B4 B3 B2 B1 Reset  
• Move to “Reset” (UP) position and leave it there. This is the  
factory default setting.  
CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery  
charge equalization should only be performed in strict accordance with the battery manufacturers  
instructions and specifications.  
Equalize  
batteries; consult with your battery’s manufacturer to determine if  
your batteries could benefit from this process. The charge equaliza-  
tion process is automatic; once started, it can only be stopped by  
removing the input power.  
Battery Charge  
Reset  
Switch Position  
Up (factory setting)  
Down—momentarily  
Equalize  
Set Battery Charging Amps—OPTIONAL (function included  
Battery Charger  
Low Charge Amps  
High Charge Amps  
Switch Position  
Up  
B4  
on  
switch on 612 models)  
A4  
Down (factory setting)  
Check specifications for your unit’s high- and  
low-charging amp options. By setting on  
high charging, your batteries will charge at  
maximum speed and your RV 12V DC  
system loads will be well-supplied. When  
B4 B3 B2 B1  
CAUTION: When switching to the High Charge Amp setting, the user must ensure that the  
amp hour capacity of their battery system exceeds the amperage of the High Charge Amp  
setting or the batteries may be damaged or degraded.  
setting on low charging, you lengthen the life of your batteries  
(especially smaller ones).  
Set Battery Charge Conserver (Load Sense) Dial—OPTIONAL (Not on 612 models)  
In order to save battery power, the unit’s inverter automatically shuts off in the absence of any power demand from connected  
equipment or appliances (the electrical load). When the unit detects a load, it automatically turns its inverter function on.  
Users may choose the minimum load the Inverter/Charger will detect by adjusting the Battery Charge Conserver Dial (see  
diagram). Using a small tool, turn the dial clockwise to lower the minimum load that will be detected, causing the inverter to  
turn on for smaller loads. When the dial is turned fully clockwise, the inverter will operate even when there is no load. Turn the  
dial counterclockwise to increase the minimum load that will be detected, causing the inverter to stay off until the new minimum load is reached.  
Note: the factory setting for the dial is fully clockwise. However, based on the threshold load to which you’d like the inverter to respond, you should adjust the dial counterclockwise to reduce its sensi-  
tivity until the inverter is active only when connected equipment or appliances are actually in use.  
Connect Remote Control—OPTIONAL (All models)  
All models feature an 8-conductor telephone style receptacle on the front panel for use with an optional remote control module (Tripp Lite model  
APSRM, sold separately or included with select models). The remote module allows the Inverter/Charger to be mounted in a compartment or cabinet out  
of sight, while operated conveniently from within the living area or control panel of your RV. See instructions packed with the remote control module.  
Connect Battery Temperature Sensing Cable—OPTIONAL (not on 612 models)  
The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature. Connect  
the sensor cable (the cable, included with select models, has an RJ style connector on one end and a black sensor on the other) to the RJ  
style jack located on the side of the Inverter/Charger labeled “Remote Temp. Sense.” With user-supplied electrical or duct tape, affix the sensor  
to the side of the battery below the electrolyte level. Make sure that nothing, not even tape, comes between the sensor and the side of the battery.  
To guard against false readings due to ambient temperature, place the sensor between batteries, if possible, or away from sources of extreme  
heat or cold. If the sensor cable is not used, the Inverter/Charger will charge according to its default 25º C values.  
Utilize Automatic Generator Starter Capability—OPTIONAL (not on 612 models)  
Pin Configuration  
1
2 - Common  
All models except 612 models include an RJ type modular jack on the side panel labeled “Generator Start”. Attach to vehicle  
generator ON/OFF switching mechanism with user-supplied cable (see Pin Configuration Diagram). Once  
attached, the interface will allow the Inverter/Charger to automatically switch a vehicle generator on when connected bat-  
tery voltage levels are low (11.6 VDC) and switch it off when battery voltage levels are high (14.1 VDC).  
2
4
6
3 - N.C.  
3
5
(Normally Closed)  
4 - N.O.  
(Normally Open)  
8R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Selection  
Select Auxiliary Battery Type (if any)  
Select “Deep Cycle” batteries to receive optimum performance from your Inverter/Charger. Do not use ordinary car or starting batteries or batteries rated in  
Cold Cranking Amps (CCA). If the batteries you connect to the Inverter/Charger are not true Deep Cycle batteries, their operational lifetimes may be significantly  
shortened. If you are using the same battery bank to power the Inverter/Charger as well as DC loads, your battery bank will need to be appropriately  
sized (larger loads will require a battery bank with a larger amp-hour capacity) or the operational lifetimes of the batteries may be significantly shortened.  
Batteries of either Wet-Cell (vented) or Gel-Cell /Absorbed Glass Mat (sealed) construction are ideal. 6-volt “golf cart”, Marine Deep-Cycle or  
8D Deep-Cycle batteries are also acceptable. You must set the Inverter/Charger’s Battery Type DIP Switch (see Configuration section for more  
information) to match the type of batteries you connect or your batteries may be degraded or damaged over an extended period of time. In  
many cases, the vehicle battery may be the only one installed. Auxiliary batteries must be identical to the vehicle batteries if they are con-  
nected to each other.  
Match Battery Amp-Hour Capacity to Your Application  
Select a battery or system of batteries that will provide your Inverter/Charger with proper DC voltage and an adequate amp-hour capacity  
to power your application. Even though Tripp Lite Inverter/Chargers are highly-efficient at DC-to-AC inversion, their rated output capacities  
are limited by the total amp-hour capacity of connected batteries and the support of your vehicle’s alternator if the engine is kept running.  
Example  
Tools  
• STEP 1: Determine Total Wattage Required  
¼" Drill  
Orbital Sander  
Cordless Tool Charger  
Add the wattage ratings of all equipment you will connect to your Inverter/Charger.  
Wattage ratings are usually listed in equipment manuals or on nameplates. If your  
equipment is rated in amps, multiply that number timesAC utility voltage to determine  
watts. (Example: a ¼ in. drill requires 2½ amps. 2½ amps × 120 volts = 300 watts .)  
Note: Your Inverter/Charger will operate at higher efficiencies at about 75% - 80% of nameplate rating.  
300W  
+
220W  
+
20W  
=
540W  
Appliances  
Blender  
Color TV  
Laptop Computer  
300W  
+
140W  
+
100W  
=
540W  
• STEP 2: Determine DC Battery Amps Required  
Divide the total wattage required (from step 1, above) by the battery voltage (12)  
to determine the DC amps required.  
540 watts ÷ 12V = 45 DC Amps  
• STEP 3: Estimate Battery Amp-Hours Required (for operation unsupported  
by the alternator)  
Multiply the DC amps required (from step 2, above) by the number of hours you  
estimate you will operate your equipment exclusively from battery power  
before you have to recharge your batteries with utility- or generator-supplied  
AC power. Compensate for inefficiency by multiplying this number by 1.2.  
This will give you a rough estimate of how many amp-hours of battery power  
(from one or several batteries) you should connect to your Inverter/Charger.  
45 DC Amps × 5 Hrs. Runtime  
× 1.2 Inefficiency Rating = 270 Amp-Hours  
NOTE! Battery amp-hour ratings are usually given for a 20-hour discharge rate. Actual amp-hour capacities are less  
when batteries are discharged at faster rates. For example, batteries discharged in 55 minutes provide only 50% of  
their listed amp-hour ratings, while batteries discharged in 9 minutes provide as little as 30% of their amp-hour ratings.  
• STEP 4: Estimate Battery Recharge Required, Given Your Application  
You must allow your batteries to recharge long enough to replace the charge  
lost during inverter operation or else you will eventually run down your batteries.  
To estimate the minimum amount of time you need to recharge your batteries  
given your application, divide your required battery amp-hours (from step 3,  
above) by your Inverter/Charger’s rated charging amps (see Specifications section).  
270 Amp-Hours ÷ 55 Amps  
Inverter/Charger Rating = 5 Hours Recharge  
NOTE! For Tripp Lite Inverter/Chargers providing 1000 watts or less of continuous AC power, a full-size battery  
will normally allow sufficient power for many applications before recharging is necessary. For mobile applications,  
if a single battery is continuously fed by an alternator at high idle or faster, then recharging from utility or generator  
power may not be necessary. For Tripp Lite Inverter/Chargers over 1000 watts used in mobile applications, Tripp Lite  
recommends you use at least two batteries, if possible fed by a heavy-duty alternator anytime the vehicle is running.  
Tripp Lite Inverter/Chargers will provide adequate power for ordinary usage within limited times without the  
assistance of utility or generator power. However, when operating extremely heavy electrical loads at their peak  
in the absence of utility power, you may wish to “assist your batteries” by running an auxiliary generator or vehicle  
engine, and doing so at faster than normal idling.  
9R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting  
WARNING! Mount your Inverter/Charger BEFORE DC battery and AC power  
connection. Failure to follow these instructions may lead to personal injury  
and/or damage to the Inverter/Charger and connected systems.  
Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of different mounting options for use in vehicular or non-vehicular  
applications. Tripp Lite recommends permanent mounting of your Inverter/Charger in any of the configurations illustrated below. User must  
supply mounting hardware and is responsible for determining if the hardware and mounting surface are suitable to support the weight of the  
Inverter/Charger. Contact Tripp Lite if you require further assistance in mounting your Inverter/Charger.  
612 Models Only  
All Models Except 612 Models  
Whether mounted horizontally or vertically, the  
Inverter must be located in an enclosed compartment,  
shielded from outside weather conditions.  
Note: When operating RV1012UL and RV2012UL  
models in a marine application, refer to the  
accompanying marine owners' manual addendum.  
A
Using the measurements from the diagram, install two user-sup-  
Whether mounted horizontally or vertically, the  
Inverter must be located in an enclosed compartment,  
shielded from outside weather conditions.  
plied ¼" (6 mm) fasteners into a rigid horizontal surface, leaving  
B
the heads slightly raised. Slide the Inverter/Charger back over  
the fasteners to engage the mounting slots molded on the bottom of  
A
Using the measurements from the diagram, install two user-sup-  
plied ¼" (6 mm) fasteners into a rigid horizontal surface, leaving  
the heads slightly raised. Slide the Inverter/Charger forward  
C
the Inverter/Charger cabinet. Install and tighten two user-sup-  
plied ¼" (6 mm) fasteners into the mounting feet molded on the  
front of the Inverter/Charger cabinet.  
B
over the fasteners to engage the mounting feet molded on the  
front of the Inverter/Charger cabinet. Install and tighten  
additional user-supplied ¼" (6 mm) fasteners into the mounting  
feet molded on the rear and sides of the Inverter/Charger  
cabinet*. The rear feet extend beyond the unit’s cabinet to  
provide for adequate ventilation space behind the cooling fan(s);  
they should not be removed.  
The polycarbonate cabinet and mounting feet of your  
Inverter/Charger are durable enough to allow for vertical mount-  
ing as well, if your vehicle compartment requires this configura-  
tion. For vertical mounting, the control panel of the  
Inverter/Charger should face up.  
The polycarbonate cabinet and mounting feet of your  
Inverter/Charger are durable enough to allow for vertical mount-  
ing as well, if your vehicle compartment requires this configura-  
tion. For vertical mounting, the control panel of the  
Inverter/Charger should face up.  
C
A
4.5 in.  
(11.4 cm)  
B
6.75 in.  
(17.1 cm)  
5.57 in.  
(14.16 cm.)  
9.59 in.  
6.75 in.  
(24.35 cm.)  
(17.1 cm)  
7.87 in.  
B
(20 cm)  
5.87 in.  
9.59 in.  
(14.91 cm.)  
(24.35 cm.)  
5.57 in.  
5.87 in.  
(14.16 cm.)  
(14.91 cm.)  
A
1.64 in.  
(4.15 cm.)  
Note: RV model cabinets may have different front panel features, but all mount as per the figure above, or via the Lateral  
Mounting Bracket, illustrated at left.  
* All models include front and rear mounting feet. Select  
models include side mounting feet.  
10R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Connection  
Connect your Inverter/Charger to your batteries using the following procedures:  
• Connect DC Wiring: Though your capable of delivering peak wattage at up to See the Feature Identification section to locate  
Inverter/Charger is a  
high-efficiency con-  
verter of electricity,  
its rated output  
capacity is limited by  
the length and gauge  
of the cabling run-  
ning from the bat-  
tery to the unit. Use  
the shortest length  
and largest diameter  
cabling (maximum  
2/0 gauge) to fit  
200% of its rated continuous wattage output the Main Ground Lug on your specific  
for brief periods of time. See Specifications Inverter/Charger model. All installations  
page for details. Heavier gauge cabling must comply with national and local codes  
should be used when continuously operating and ordinances.  
heavy draw equipment under these conditions.  
• Connect Fuse: NEC (National Electrical  
Tighten your Inverter/Charger and battery  
Code) article 551 requires that you connect  
terminals to approximately 3.5 Newton-  
all of your Inverter/Charger’s positive DC  
meters of torque to create an efficient con-  
Terminals directly to a UL-listed fuse(s) and  
nection and to prevent excessive heating at  
fuse block(s) within 18 inches of the battery.  
this connection. Insufficient tightening of  
The fuse’s rating must equal or exceed the  
the terminals could void your warranty. See  
Minimum DC Fuse Rating listed in your  
Specifications page for Minimum  
Inverter/Charger’s specifications. See  
Recommended Cable Sizing Chart.  
DC Connectors  
Dual DC Connectors (See  
note at bottom of the page)  
Specifications for fuse and fuse block rec-  
your Inverter/Charger’s DC Input terminals.  
Shorter and heavier gauge cabling reduces  
DC voltage drop and allows for maximum  
transfer of current. Your Inverter/Charger is  
ommendations. See diagrams below for  
• Connect Ground: Using a #8 AWG wire  
proper fuse placement.  
or larger directly connect the Main Ground  
Lug to the vehicle’s chassis or earth ground.  
WARNING! • Failure to properly ground your Inverter/Charger to a vehicle’s chassis or earth  
ground may result in a lethal electrical shock hazard.  
• Never attempt to operate your Inverter/Charger by connecting it directly to output from an  
alternator rather than a battery or battery bank.  
• Observe proper polarity with all DC connections.  
Vehicular  
Your Inverter/Charger’s Nominal DC Input Voltage must match the voltage of your battery or batteries—12 Volts in most vehicular applications.  
It is possible to connect your Inverter/Charger to the main battery within your vehicle’s electrical system. In most vehicles, the Inverter/Charger will be  
connected to one or more dedicated auxiliary (house) batteries which are isolated from the drive system to prevent possible draining of the main battery.  
3
7
2
8
1
12 Volts  
12 Volt Inverter/Charger  
12 Volts  
5
12 Volt Main Battery Connection  
4
7
8
6
2
12 Volts  
1
12 Volt Inverter/Charger  
12 Volts  
5
3
2
12 Volts  
12 Volt Main and Auxiliary (House) Battery Connection (Isolated Parallel)  
1
2
3
4
5
12 Volt Alternator  
Vehicle Battery Ground  
6
12 Volt Main Battery  
12 Volt Auxiliary (House) Battery  
UL-Listed Fuse & Fuse Block (mounted  
7
8
within 18 inches of the battery)  
Battery Isolator  
Large Diameter Cabling, Maximum 2/0 Gauge to Fit Terminals  
8 AWG (minimum) Ground Wire  
NOTE: Select models include two positive and two negative DC terminals. Using the same connection architecture illustrated in the diagrams, run two 2/0 gauge cables from the Inverter/Chargers  
two negative terminals to the batterys single negative terminal; run two 2/0 gauge cables from the Inverter/Chargers two positive terminals, through two UL-listed fuses and fuse blocks, or equivalent,  
(one on each cable), to the batterys single positive terminal. Use the equivalent of two 2/0 cables in all other connections within the battery system. Connection to Two DC Terminals: It is acceptable  
to use two cables to connect your battery to only one positive and one negative DC terminal, however, your Inverter/Charger will provide reduced output power. It doesnt make a difference which  
positive and negative terminal you choose for the connection because both positive terminals are internally bonded and both negative terminals are also internally bonded. In this connection you  
must run one positive cable through one user-supplied UL-listed fuse and fuse block.  
11R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AC Input/Output Connection  
To avoid overloading your Inverter/Charger, match the power requirements of the equipment you plan to run at any one time (add their total  
watts) with the output wattage capacity of your Inverter/Charger model (see Specifications). Do not confuse “continuous” wattage with  
“peak” wattage ratings. Most electric motors require extra power at start-up (“peak wattage”) than required to run continuously after start-  
up, sometimes over 100% more. Some motors, such as in refrigerators and pumps, start and stop intermittently according to demand, requir-  
ing “peak wattage” at multiple, unpredictable times during operation. DoubleBoostFeature: Tripp Lite Inverter/Chargers deliver up to twice  
their nameplate rated wattage for up to 10 seconds,* providing the extra power needed to cold start heavy-duty tools and equipment.  
OverPowerFeature: Tripp Lite Inverter/Chargers deliver up to 150% of their name-plate rated wattage for up to 1 hour,* providing plenty  
of reserve power to reliably support tools and equipment longer.  
* Actual duration depends on model, battery age, battery charge level and ambient temperature.  
Connection for Models with Cords and Receptacles  
Plug the Inverter/Charger’s AC input cord into an outlet providing 120V AC, 60Hz. power. Make sure that the circuit you connect your  
Inverter/Charger to has adequate overload protection, such as a circuit breaker or a fuse. Plug your equipment into the Inverter/Charger’s AC  
receptacles. Any equipment you connect to it will benefit from your Inverter/Charger’s built-in ISOBAR® surge protection!  
Warning! Consult a qualified electrician and follow all applicable electrical codes and requirements  
for hardwire connection. Disconnect both DC input and AC utility supply before attempting hardwiring.  
Use wire type THHN or equivalent with minimum temperature rating of 90°C.  
Connection for Models with Hardwire Terminals  
Output Connection Requirement: UL requires that the output terminals of all hard-  
wire Inverter/Charger models must be connected to UL-listed GFCI receptacles  
“FOR USE WITH COPPER WIRE ONLY”  
(required receptacle manufacturer/model series: Hubbell GF8300HGW or  
HOT IN  
NEUTRAL IN  
Leviton 6598).  
2
3
1
4
5
GROUND IN  
GROUND OUT  
HOT OUT  
Single Input/Output Models  
Input: Connect incoming wires to the hot (brown) , neutral (blue)  
2
3
NEUTRAL OUT  
1
and ground* (green) terminals  
.
4
5
Note: Ground Bond Connection, Supplied  
Output: Connect outgoing wires to the hot (black)  
and ground* (green) terminals 1 .  
, neutral (white)  
Replace cover plate and tighten screws.* If the incoming conduit only contains two wires (hot and neutral), the incoming conduit must be bonded to the main ground lug on the unit. In any case,  
the incoming conduit must be bonded to earth or vehicle ground, and the incoming conduit must be bonded to the outgoing conduit.  
Dual Input/Output Models  
Select models provide higher bypass power capacity by enabling connection of two separate  
AC input sources. These two sources can be either two 120V legs split from a single 240V  
service (with opposite phase on each 120V leg) or two different 120V sources. The  
Inverter/Charger will only supply 120V output power and WILL NOT provide 240V output  
even if it is connected to inputs from a split 240V service when in inverter mode. When the  
Inverter/Charger is receiving AC power, it can supply connected loads with up to 20 amps  
of power on each circuit**. When the Inverter/Charger is not receiving AC power, and has  
AC IN 1  
switched to inverting DC battery power, it can supply connected loads with various amper-  
age levels (see “Maximum Output AC Current” in Specifications section) on BOTH circuits.  
Dual input/output models provide for either: a) dual-source inputs and outputs; b) single-  
source input and output; or c) single-source input and dual-source outputs (with AC OUT  
2 power only available in invert mode). Connect user-supplied wire and conduit to the con-  
nections as follows:  
AC IN 2  
AC OUT 2  
AC OUT 1  
Input: Connect incoming wires to hot (black for AC IN 1, black for AC IN 2), neutral  
(white for AC IN 1, white for AC IN 2) and ground (green/yellow) wires.  
Output: Connect outgoing wires to hot (black for AC OUT 1, black for AC OUT 2), neutral  
(white for AC OUT 1, white for AC OUT 2) and ground (green/yellow) wires.  
Dual-Source Input/Output*  
Single-Source Input/Output*  
• AC IN 1 will only provide line power to AC OUT 1.  
• AC IN 2 will only provide line power to AC OUT 2.  
• Inverted battery power is supplied to both AC OUT 1 and AC OUT 2.  
• If you only have a single 120V AC input source, you must  
connect it to AC IN 1.  
• If you only have a single output circuit, you must connect it to  
AC OUT 1  
* Single-Source or Dual-Source Input/Output Connection: As well as supplying power to connected loads, AC IN 1 also provides power to the battery charger. If you connect a large load to AC OUT 1,  
you should select a more limiting battery charger setting (see “Select Battery Charger-Limiting Points”) or you may experience continual nuisance tripping of the electrical service (source) circuit  
breaker which supplies AC IN 1. The Inverter/Charger will only measure the current at AC OUT 1 to automatically limit the charger rate. AC IN 2 input current is passed through to AC OUT 2 with-  
out measurement. Single-Source Input/Dual-Source Output Connection: You may connect AC IN 1 and AC IN 2 to a single source to provide power to AC OUT 1 and AC OUT 2. However, the loads connected to  
AC OUT 2 will not be measured for the purpose of automatic charger limitation. This could result in occasional tripping of the electrical service (source) circuit breaker. If this occurs, reduce the load on AC OUT  
2 until nuisance tripping stops.  
** Load circuit breaker limited.  
12R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service  
Before returning your Inverter/Charger for service, follow these steps: 1.) Review the installation and operation instructions to ensure that  
the service problem does not originate from a misreading of the instructions. Also, check that the circuit breaker(s) are not tripped.* 2.) If  
the problem continues, do not contact or return the Inverter/Charger to the dealer. Instead, call Tripp Lite at (773) 869-1233. A service tech-  
nician will ask for the Inverter/Charger’s model number, serial number and purchase date and will attempt to correct the problem over the  
phone. 3.) If the problem requires service, the technician will issue you a Returned Material Authorization (RMA) number, which is  
required for service. Securely pack the Inverter/Charger to avoid damage during shipping. Do not use Styrofoam beads for packaging.**  
Any damages (direct, indirect, special, incidental or consequential) to the Inverter/Charger incurred during shipment to Tripp Lite or an  
authorized Tripp Lite service center is not covered under warranty. Inverter/Chargers shipped to Tripp Lite or an authorized Tripp Lite serv-  
ice center must have transportation charges prepaid. Mark the RMA number on the outside of the package. If the Inverter/Charger is with-  
in the warranty period, enclose a copy of your sales receipt. Return the Inverter/Charger for service using an insured carrier to the address  
given to you by the Tripp Lite service technician.  
* This is a common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual. ** If you require packaging, the technician can arrange to send you proper packaging.  
Maintenance  
Your Inverter/Charger requires no maintenance and contains no user-serviceable or replaceable parts, but should be kept dry at all times.  
Periodically check, clean and tighten all cable connections, as necessary, both at the unit and at the battery.  
Troubleshooting  
Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234  
before returning your unit for service.  
SYMPTOM  
PROBLEMS  
CORRECTIONS  
No AC Output  
Unit is not properly connected to utility power  
Connect unit to utility power.  
(All Indicator Lights are OFF)  
Operating Mode Switch is set to “OFF” and AC input  
is present.  
Set Operating Mode Switch to “AUTO/REMOTE” or “CHARGE ONLY”.  
This is normal when the Operating Mode Switch is set to  
“CHARGE ONLY” and AC input is absent.  
No correction is required. AC output will return when AC input  
returns. Set Operating Mode Switch to “AUTO/REMOTE” if you  
require AC output.  
Circuit breaker is tripped.  
Reset circuit breaker.  
Unit has shut down due to battery overcharge (preventing  
battery damage). The problem may be with connected  
auxiliary chargers, if any, or with the unit’s charger.  
Disconnect any auxiliary chargers. Reset by moving Operating Mode  
Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE” or  
“CHARGE ONLY.” If unit remains in shutdown mode after several  
attempts to reset, contact Tripp Lite Customer Service for assistance.  
Unit has shut down due to excessive battery discharge.  
Unit has shut down due to overload.  
Use an auxiliary charger* to raise battery voltage. Check external  
battery connections and fuse. Unit automatically resets when  
condition is cleared.  
Reduce load. Reset by moving Operating Mode Switch to “OFF”.  
Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.  
Battery Not Recharging  
(AC Input Present)  
Connected batteries are dead.  
Battery fuse* is blown.  
Check and replace old batteries.  
Check and replace fuse.*  
Battery cabling* is loose.  
Check and tighten or replace cabling.*  
Unit has shut down due to battery overcharge (preventing  
battery damage). The problem may be with connected  
auxiliary chargers, if any, or with the unit’s charger.  
Disconnect any auxiliary chargers. Reset by moving Operating Mode  
Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE” or  
or “CHARGE ONLY.” If unit remains in shutdown mode after several  
attempts to reset, contact Tripp Lite Customer Service for assistance.  
Input circuit breaker is tripped.  
Reset circuit breaker.  
All Three “BATT VOLT/CHRG CURR”  
LEDs are slowly flashing (½ second  
flashes) with Operating Mode Switch in  
the “AUTO/REMOTE” position.  
Battery is excessively discharged. Unit will shut down to  
prevent battery damage.  
Use an auxiliary charger* to raise battery voltage. Check external  
battery connections and fuse. Unit automatically resets when  
condition is cleared.  
All Three “BATT VOLT/CHRG CURR”  
LEDs are rapidly flashing (¼ second  
flashes) with Operating Mode Switch in  
the “AUTO/REMOTE” position.  
Battery is overcharged. Unit will shut down to prevent  
battery damage. The problem may be with connected auxiliary Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE.”  
chargers, if any, or with the unit’s charger.  
Disconnect any auxiliary chargers. Reset by moving Operating Mode  
If unit remains in shutdown mode after several attempts to reset,  
contact Tripp Lite Customer Service for assistance.  
Red “LOW” Battery Indicator Light is  
flashing with Operating Mode Switch in the to protect battery from damage.  
”AUTO/REMOTE” position.  
Battery voltage is low. Unit has shut down  
If AC power (utility- or generator-supplied) is present, the unit will  
automatically reset itself and start recharging connected batteries.  
However, if an external charger is used to recharge the batteries,  
you will need to manually reset the unit by moving the Operating  
Mode Switch to “OFF” for two seconds then returning it to  
“AUTO/REMOTE”.  
False reading due to undersized or  
insufficiently connected DC cabling.  
Use sufficient size DC cable sufficiently connected to  
Inverter/Charger.  
Red “LOAD” Operation  
Indicator Light flashing  
Inverter is overloaded. Unit will automatically shut down  
after 5 seconds.  
Reduce load. Reset by moving Operating Mode Switch to “OFF”.  
Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.  
* User-supplied.  
13R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1111 W. 35th Street, Chicago, IL 60609 USA  
773.869.1234 (USA) • 773.869.1212 (International)  
200502023 93-2254_ES  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TERK Technologies TV Video Accessories Advantage User Manual
Toshiba Computer Drive MK3019GAX User Manual
TP Link Network Router TL R480T+ User Manual
Tricity Bendix Oven TBD913 User Manual
Uniden Cordless Telephone DCT5280 User Manual
Uniden Cordless Telephone DSS 2475 User Manual
Victor Technology Calculator 1200 4 User Manual
Vinotemp Refrigerator V5LR 2009 User Manual
Vivotek Digital Camera PT3112 3122 User Manual
Vizio Flat Panel Television E390IA1 User Manual