Tripp Lite Battery Charger APSX1250 User Manual

Òåõíè÷åñêèå õàðàêòåðèñòèêè  
Specifications  
ÍÎÌÅÐ ÌÎÄÅËÈ  
APSX750  
APSX1250  
APSX2012  
Ìîíòàæíîå ñîåäèíåíèå  
APSX2424  
Ìîíòàæíîå ñîåäèíåíèå  
MODEL NUMBER:  
APSX750  
Detachable IEC-320 Input Cord  
APSX1250  
Detachable IEC-320 Input Cord  
APSX2012  
Hardwire  
APSX2424  
Hardwire  
Âõîäíîå ñîåäèíåíèå ïåðåìåííîãî òîêà: Îòñîåäèíÿåìûé âõîäíîé êàáåëü IEC-320  
Îòñîåäèíÿåìûé âõîäíîé êàáåëü IEC-320  
AC Input Connection:  
ÈÍÂÅÐÒÎÐ  
INVERTER  
Common Specifications for All Models • Output Volts (Nominal): 230 VAC, 5% • Output Frequency (Nominal): 50 Hz, 0.5% • Efficiency: 85% to 94%, depending on load and temperature  
Îáùèå òåõíè÷åñêèå õàðàêòåðèñòèêè äëÿ âñåõ ìîäåëåé • Âûõîäíîå íàïðÿæåíèå (Íîìèíàëüíîå): 230  ïåðåìåííîãî òîêà, 5% • Âûõîäíàÿ ÷àñòîòà (Íîìèíàëüíàÿ): 50 Ãö, 0,5% • Êîýôôèöèåíò ïîëåçíîãî äåéñòâèÿ:  
îò 85% äî 94%, â çàâèñèìîñòè îò íàãðóçêè è òåìïåðàòóðû  
Îòäåëüíûå Èíâåðòîðû/Çàðÿäíûå óñòðîéñòâà Tripp Lite âêëþ÷àþò ñðåäñòâî óïðàâëåíèÿ ñèñòåìîé ñáåðåæåíèÿ çàðÿäà áàòàðåè  
(Îáíàðóæåíèå íàãðóçêè), êîòîðàÿ ýêîíîìèò ýíåðãèþ áàòàðåè, ïîçâîëÿÿ ïîëüçîâàòåëÿì óñòàíîâèòü ìèíèìàëüíûé óðîâåíü íàãðóçêè,  
ïðè êîòîðîì âêëþ÷àåòñÿ èíâåðòîð áëîêà. Ñ ïîìîùüþ ýòîãî ñðåäñòâà óïðàâëåíèÿ ïîëüçîâàòåëè ìîãóò ñóùåñòâåííî óìåíüøèòü ñèëó  
âõîäíîãî ïîñòîÿííîãî òîêà, ñîîòâåòñòâóþùóþ îòñóòñòâèþ íàãðóçêè, äî î÷åíü íèçêèõ óðîâíåé.  
Select Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allow-  
ing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input  
Current to a very low amp level with the use of this control.  
Continuous Power (@ 20°C):  
OverPower™ Peak Surge Power:*  
Double Boost™ Peak Surge Power:*  
DC Input Volts (Nominal):  
750  
1125  
1250  
1875  
2000  
3000  
2400  
3600  
Íåïðåðûâíàÿ ìîùíîñòü (ïðè òåìïåðàòóðå 20°C):  
Ïèêîâàÿ ìîùíîñòü OverPowerTM:*  
Ïèêîâàÿ ìîùíîñòü DoubleBoostTM:*  
750  
1125  
1500  
1250  
1875  
2500  
2000  
3000  
4000  
2400  
3600  
4800  
1500  
2500  
4000  
4800  
12 VDC  
10-15 VDC  
150 A  
12 VDC  
10-15 VDC  
225 A  
12 VDC  
10-15 VDC  
400 A  
24 VDC  
20-30 VDC  
225 A  
Âõîäíîå íàïðÿæåíèå ïîñòîÿííîãî òîêà  
DC Input Voltage Range:  
(Íîìèíàëüíîå):  
12 Â ïîñòîÿííîãî òîêà  
10-15 Â ïîñòîÿííîãî òîêà  
150 A  
12 Â ïîñòîÿííîãî òîêà  
10-15 Â ïîñòîÿííîãî òîêà  
225 A  
12 Â ïîñòîÿííîãî òîêà  
10-15 Â ïîñòîÿííîãî òîêà  
400 A  
24 Â ïîñòîÿííîãî òîêà  
20-30 Â ïîñòîÿííîãî òîêà  
225 A  
Minimum DC Fuse Rating:  
Äèàïàçîí âõîäíîãî íàïðÿæåíèÿ  
ïîñòîÿííîãî òîêà:  
DC Input Current @ Nominal V DC  
Full Load:  
72 A  
125 A  
192 A  
112 A  
Ìèíèìàëüíûé íîìèíàëüíûé òîê  
ïðåäîõðàíèòåëÿ ïîñòîÿííîãî òîêà:  
BATTERY CHARGER  
Âõîäíîé òîê ïîñòîÿííîãî òîêà ïðè íîìèíàëüíîì  
íàïðÿæåíèè ïîñòîÿííîãî òîêà è ïîëíîé íàãðóçêå 72 A  
Common Specifications for All Models • Input Volts (Nominal): 230 VAC  
125 A  
192 A  
112 A  
Charging Capacity DC:  
20 A**/5 A  
30 A/7.5 A**  
14.4 V/14.2 V  
60 A/15 A**  
30 A/7.5 A**  
28.8 V/28.4 V  
ÓÑÒÐÎÉÑÒÂÎ ÇÀÐßÄÊÈ ÁÀÒÀÐÅÈ  
Acceptance Volts VDC:  
Selectable (Wet**/Gel)  
14.4 V/14.2 V  
14.4 V/14.2 V  
Îáùèå òåõíè÷åñêèå õàðàêòåðèñòèêè äëÿ âñåõ ìîäåëåé • Âõîäíîå íàïðÿæåíèå (Íîìèíàëüíîå): 230  ïåðåìåííîãî òîêà  
Float Volts VDC (Wet/Gel):  
13.3 V (13.6 V)  
2 A  
13.3 V (13.6 V)  
3 A  
13.3 V (13.6 V)  
7 A  
26.6 V (27.2 V)  
7 A  
Ïîñòîÿííûé òîê çàðÿäêè:  
20 A**/5 A  
30 A/7.5 A**  
60 A/15 A**  
30 A/7.5 A**  
Input Current AC (Maximum):  
Äîïóñòèìîå íàïðÿæåíèå ïîñòîÿííîãî òîêà:  
Âûáîð òèïà áàòàðåè (Æèäêîñòíàÿ**/Ãåëåâàÿ)  
14.4 Â/14.2 Â  
14.4 Â/14.2 Â  
14.4 Â/14.2 Â  
28.8 Â/28.4 Â  
LINE VAC OPERATION  
Íàïðÿæåíèå ïîñòîÿííîãî òîêà áåç íàãðóçêè  
(Æèäêîñòíàÿ/Ãåëåâàÿ):  
Common Specifications for All Models • Minimum Input Volts (Transfer to Battery): Selectable 144,** 163, 182, 201 VAC • Maximum Input Volts (Transfer to Battery): Selectable 259** or 278 VAC on  
APSX2424 only • Input Frequency (Nominal): 50 Hz, 10%  
13.3 Â (13.6 Â)  
13.3 Â (13.6 Â)  
3 A  
13.3 Â (13.6 Â)  
7 A  
26.6 Â (27.2 Â)  
7 A  
Ñèëà âõîäíîãî ïåðåìåííîãî òîêà (Ìàêñèìàëüíàÿ):  
2 A  
Total Input AC Current  
(Continuous, Charger at Maximum):  
ÝÊÑÏËÓÀÒÀÖÈß ËÈÍÅÉÍÎÃÎ ÍÀÏÐßÆÅÍÈß ÏÅÐÅÌÅÍÍÎÃÎ ÒÎÊÀ  
6 A  
4 A  
9 A  
6 A  
17 A  
10 A  
19 A  
12 A  
Maximum Bypass AC  
Current (Continuous):  
Îáùèå òåõíè÷åñêèå õàðàêòåðèñòèêè äëÿ âñåõ ìîäåëåé • Ìèíèìàëüíîå âõîäíîå íàïðÿæåíèå (Ïåðåäàâàåìîå íà áàòàðåþ): Âûáèðàåòñÿ 144, ** 163, 182, 201  ïåðåìåííîãî òîêà • Ìàêñèìàëüíîå âõîäíîå  
íàïðÿæåíèå (Ïåðåäàâàåìîå íà áàòàðåþ): Âûáèðàåòñÿ 259 ** èëè 278 Â ïåðåìåííîãî òîêà òîëüêî äëÿ ìîäåëè APSX2424 • Âõîäíàÿ ÷àñòîòà (Íîìèíàëüíàÿ): 50 Ãö, 10%  
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature.  
** Factory setting. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. This product designed and engineered in the USA.  
Îáùàÿ ñèëà âõîäíîãî ïåðåìåííîãî òîêà (Íåïðåðûâíûé,  
óñòðîéñòâî çàðÿäêè â ìàêñèìàëüíîì ðåæèìå):  
6 A  
9 A  
6 A  
17 A  
10 A  
19 A  
12 A  
Ìàêñèìàëüíàÿ ñèëà îáõîäíîãî ïåðåìåííîãî òîêà  
(Íåïðåðûâíîãî):  
4 A  
* Ïðîäîëæèòåëüíîñòü ðåæèìà OverPower (äî 1 ÷àñà). Ïðîäîëæèòåëüíîñòü ðåæèìà DoubleBoost (äî 10 ñåêóíä). Ðåàëüíàÿ ïðîäîëæèòåëüíîñòü çàâèñèò îò âîçðàñòà áàòàðåè, óðîâíÿ çàðÿäà áàòàðåè è îêðóæàþùåé òåìïåðàòóðû.  
** Çàâîäñêàÿ íàñòðîéêà. Êîìïàíèÿ Tripp Lite ïðèäåðæèâàåòñÿ ïîëèòèêè íåïðåðûâíîãî óëó÷øåíèÿ. Òåõíè÷åñêèå õàðàêòåðèñòèêè ïîäëåæàò èçìåíåíèþ áåç óâåäîìëåíèÿ. Ýòî èçäåëèå ñêîíñòðóèðîâàíî è ñïðîåêòèðîâàíî â ÑØÀ.  
Minimum Recommended Cable Sizing Charts†  
Use in conjunction with DC wiring connection instructions in the Battery Connection section.  
Òàáëèöû ìèíèìàëüíîãî ðåêîìåíäóåìîãî ðàçìåðà êàáåëÿ†  
Èñïîëüçóéòå âìåñòå ñ èíñòðóêöèÿìè ïî ïðîâîäíûì ñîåäèíåíèÿì ïîñòîÿííîãî òîêà, ïðèâåäåííûì â ðàçäåëå "Ïîäêëþ÷åíèå áàòàðåè".  
Inverter/Charger DC Volt: 12  
Wire Gauge  
Inverter/Charger DC Volt: 24  
Wire Gauge  
Èíâåðòîð/Çàðÿäíîå óñòðîéñòâî ñ íàïðÿæåíèåì  
ïîñòîÿííîãî òîêà 12 Â  
Èíâåðòîð/Çàðÿäíîå óñòðîéñòâî ñ íàïðÿæåíèåì  
ïîñòîÿííîãî òîêà 24 Â  
Watts  
500  
6
4
2
0
00 (2/0)  
79 ft  
Watts  
500  
8
6
4
2
0
15 ft  
11 ft  
N/R  
N/R  
25 ft  
18 ft  
12 ft  
N/R  
39 ft  
28 ft  
20 ft  
N/R  
62 ft  
44 ft  
31 ft  
16 ft  
39 ft  
28 ft  
19 ft  
10 ft  
8 ft  
62 ft  
44 ft  
31 ft  
15 ft  
13 ft  
99 ft  
70 ft  
49 ft  
25 ft  
21 ft  
157 ft  
112 ft  
78 ft  
39 ft  
33 ft  
249 ft  
178 ft  
125 ft  
62 ft  
Êàëèáð ïðîâîäà  
Êàëèáð ïðîâîäà  
700  
56 ft  
700  
1000  
2000  
39 ft  
1000  
2000  
2400  
Ìîùíîñòü  
500  
6
4
2
0
00 (2/0)  
Ìîùíîñòü  
500  
8
6
4
2
0
20 ft  
15 ôóòîâ 25 ôóòîâ 39 ôóòîâ 62 ôóòà 79 ôóòîâ  
11 ôóòîâ 18 ôóòîâ 28 ôóòîâ 44 ôóòà 56 ôóòîâ  
39 ôóòîâ 62 ôóòà 99 ôóòîâ 157 ôóòîâ 249 ôóòîâ  
28 ôóòîâ 44 ôóòà 70 ôóòîâ 112 ôóòîâ 178 ôóòîâ  
19 ôóòîâ 31 ôóò 49 ôóòîâ 78 ôóòîâ 125 ôóòîâ  
10 ôóòîâ 15 ôóòîâ 25 ôóòîâ 39 ôóòîâ 62 ôóòà  
N/R = Not Recommended.  
52 ft  
700  
700  
Note on Labeling  
Two symbols are used on the APS labels.  
1000  
Í/Ð  
Í/Ð  
12 ôóòîâ 20 ôóòîâ 31 ôóò 39 ôóòîâ  
Í/Ð Í/Р16 ôóòîâ 20 ôóòîâ  
1000  
V~: AC Voltage  
: DC Voltage  
2000  
2000  
† NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance). Cable length is the sum of the positive cable length and the negative cable length.  
Ïðèìå÷àíèå îá ýòèêåòêàõ  
Íà ýòèêåòêàõ APS èñïîëüçóþòñÿ äâà ñèìâîëà:  
V~: Íàïðÿæåíèå ïåðåìåííîãî òîêà  
: Íàïðÿæåíèå ïîñòîÿííîãî òîêà  
Í/Ð = Íå ðåêîìåíäóåòñÿ  
2400  
8 ôóòîâ 13 ôóòîâ 21 ôóò 33 ôóòà  
52 ôóòà  
Regulatory Compliance Identification Numbers  
ÏÐÈÌÅ×ÀÍÈÅ: Äîïóñòèìàÿ ìîùíîñòü íåïîñðåäñòâåííî ñâÿçàíà ñ äëèíîé êàáåëÿ (òî åñòü, ÷åì êîðî÷å êàáåëü, òåì ëó÷øå õàðàêòåðèñòèêè). Äëèíà êàáåëÿ ÿâëÿåòñÿ ñóììîé äëèíû ïîëîæèòåëüíîãî êàáåëÿ è  
äëèíû îòðèöàòåëüíîãî êàáåëÿ.  
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings  
and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.  
Èäåíòèôèêàöèîííûå íîìåðà ñîîòâåòñòâèÿ íîðìàòèâíûì äîêóìåíòàì  
Ñ öåëüþ óäîñòîâåðåíèÿ è îáîçíà÷åíèÿ ñîîòâåòñòâèÿ íîðìàòèâíûì äîêóìåíòàì, Âàøåìó èçäåëèþ Tripp Lite íàçíà÷åí óíèêàëüíûé ñåðèéíûé íîìåð. Ýòîò ñåðèéíûé íîìåð ìîæíî íàéòè íà ýòèêåòêå çàâîäñêîé òàáëè÷êè èçäåëèÿ âìåñòå ñî âñåìè  
íåîáõîäèìûìè îòìåòêàìè è èíôîðìàöèåé î ñîãëàñîâàíèè. Ïðè çàïðîñå èíôîðìàöèè î ñîãëàñîâàíèè äëÿ ýòîãî èçäåëèÿ âñåãäà ññûëàéòåñü íà ñåðèéíûé íîìåð. Íå ñëåäóåò ïóòàòü ñåðèéíûé íîìåð ñ ìàðêèðîâî÷íûì íàçâàíèåì èëè íîìåðîì ìîäåëè  
èçäåëèÿ.  
1111 W. 35th Street, Chicago, IL 60609 U.S.A.  
1111 W. 35th Street, Chicago, IL 60609 U.S.A.  
Download from20W050w11w68.9S3-o24m08 anuals.com. All Manuals Search And Download.  

Targus Network Card Notebook Expansion USB home dock with audio pass through USER Manual User Manual
Tascam CD Player CD A550 User Manual
Texas Instruments Calculator BA 2 PLUS User Manual
Toshiba Computer Drive 3006GAL User Manual
Toshiba DVD Player HD A3KC User Manual
TP Link Marine Battery TL SM311 User Manual
Tyco Security Camera VA 3 User Manual
Uniden Security Camera UDW 10003 User Manual
Viking Gas Grill VGBQ410 3RE1 User Manual
Vulcan Hart Range V60 1 User Manual