Team Products Portable Generator PMP1200 User Manual

TEAM PRODUCTS INTERNATIONAL INC. Limited Warranty  
WhAT IS COvERED: Any defect in materials and workmanship.  
FOR hOW LONg: 2 years from date of purchase.  
WhAT WE WILL DO: If your product is defective and returned within 30 days  
after the date it was purchased, we will replace it at no charge to you. If  
returned after 30 days but within 2 years of the date of purchase we will  
repair it or, at our option, replace it at no charge to you.  
If we repair your product, we may use new or reconditioned replacement  
parts. If we choose to replace your product, we may replace it with a  
new or reconditioned one of the same or similar design. The repair or  
replacement will be warranted under our standard 2 year warranty.  
LIMITATIONS: IMPLIED WARRANTIES, INCLUDINg ThOSE OF FITNESS FOR A  
PARTICULAR PURPOSE AND MERChANTAbILITy (AN UNWRITTEN WARRANTy  
ThAT ThE PRODUCT IS FIT FOR ORDINARy USE), ARE LIMITED TO 2 yEARS  
FROM DATE OF PURChASE. WE WILL NOT PAy FOR LOSS OF TIME, INCONvE-  
NIENCE, LOSS OF USE OF yOUR PRODUCT OR PROPERTy DAMAgE CAUSED  
by yOUR PRODUCT OR ITS FAILURE TO WORk, OR ANy OThER INCIDENTAL  
OR CONSEqUENTIAL DAMAgES INCLUDINg PERSONAL INjURy.  
1200 WATT  
Power Inverter  
Some states do not allow limitations on how long an implied warranty  
lasts or the exclusion or limitation of incidental or consequential damages,  
so the above exclusions or limitations may not apply to you.  
WhAT WE ASk yOU TO DO: To get warranty service for your product,  
you must provide proof of the date of purchase. Within 30 days of the  
date it was purchased, return your product to your place of purchase for  
immediate replacement. After 30 days, but before the end of the 2 year  
warranty period, you may return the product to the following address:  
TEAM PRODUCTS INTERNATIONAL INC.  
Attn: Customer Service Returns  
35 A Continental Drive  
Wayne, Nj 07470  
We suggest that you retain your original packing material in the event  
you need to ship your product. When sending your product include your  
name, address, phone number, proof of date of purchase, and a  
description of the operating problem. After repairing or replacing your  
product, we will ship it to your home or office within four weeks.  
Owner’s Manual  
PMP1200 Models  
WhAT ThIS WARRANTy DOES NOT COvER: Among oTher ThIngS ThIS  
WArrAnTy doeS noT cover defecTS reSulTIng from AccIdenTS,  
dAmAge WhIle In TrAnSIT To our ServIce locATIon, AlTerATIonS,  
unAuThorIzed repAIr, fAIlure To folloW InSTrucTIonS, mISuSe, fIre,  
flood, And AcTS of god. If your producT IS noT covered by our  
WArrAnTy, cAll our cuSTomer ServIce number AT (888) 231-4022 To  
deTermIne WheTher We WIll repAIr your producT And oTher repAIr  
InformATIon, IncludIng chArgeS. We, AT our opTIon, mAy replAce  
rATher ThAn repAIr your producT WITh A neW or recondITIoned  
one of The SAme or SImIlAr deSIgn. The repAIr or replAcemenT WIll  
be WArrAnTed for 2 yeArS.  
ThIS lImITed WArrAnTy IS The only one We gIve on your producT,  
And IT SeTS forTh All our reSponSIbIlITIeS regArdIng your producT.  
There Are no WArrAnTIeS WhIch exTend beyond The deScrIpTIon SeT  
forTh Above.  
©2006 The Coleman Company, Inc. All rights reserved.  
STATE LAW RIghTS: This warranty gives you specific legal rights and you  
may also have other rights which may vary from state to state.  
COLEMAN® and  
are registered trademarks of The Coleman Company, Inc., used under license. Designed in the USA and  
custom-manufactured in China for Team Products International Inc. Distributed byTeam Products International Inc., Mountain Lakes, NJ 07046.  
PMP1200033106-82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Manual  
PMP1200 Models  
Notes  
Connecting the Inverter  
• Loose connections can result in a severe decrease in voltage, which may cause  
damage to the component or the product you wish to operate.  
When connecting the inverter to the power source, it is recommended to use  
the thickest wire available in the shortest length possible. If the inverter and the  
battery are positioned within 4 feet of each other, a minimum of #2 gauge wire  
should be used to make the connections. When the distance between them is  
4 to 6 feet, a minimum of #0 gauge wire is required. When separated by more  
than six feet, always use #00 gauge wire.  
• Failure to make a proper connection between the inverter and the power  
source may result in reverse polarity. Reverse polarity will blow the internal  
fuses in the inverter and may cause permanent damage to the inverter.  
Damage caused by reverse polarity is not covered under the warranty.  
Use of #0 gauge wire to make the connections to the inverter may require a “0  
to 4 Gauge Adaptor. This adaptor is available through most electrical supply  
stores.  
The audible alarm may make a momentary “chirp” when the inverter is turned  
ON(I) or OFF(O). This same alarm may also sound when the inverter is being  
connected to or disconnected from the 12-volt power source. This is normal.  
1. Make sure the ON/OFF power switch located on the front panel of the inverter  
is in the OFF(O) position.  
• If the LED Indicator Light blinks when you first turn the inverter ON(I), this may  
indicate an interruption of the power supply. Simply turn the inverter OFF(O)  
and try removing and reconnecting the clamps. If this does not fix the  
problem, try using a different 12-volt power source.  
2. Using a Phillips screwdriver, loosen the set screws in the red (+) and black (-)  
power input terminals  
• If using more than one appliance, do not exceed a combined total of  
1200 watts.  
3.The cables should be stripped approximately 5/8.  
4. Connect the cable wires to the power input terminals making sure to match  
the color coded cables to the color coded terminals on the inverter (RED=  
Positive, BLACK = Negative). Tighten the set screws to secure the cables. Be  
sure not to over tighten these screws. Note: A secure connection is essential  
to proper operation of the inverter.  
Source of Power  
Most automobile and marine batteries will provide an ample power supply to  
the inverter for 30 to 60 minutes even when the engine is turned off. Actual  
time may vary depending on the age and condition of the battery and the power  
demand being placed on it by the equipment being operated.  
5. Connect the cable from the Positive (+) terminal (RED) on the inverter to the  
Positive terminal on the power source. Double check that the connection is  
secure.  
If you decide to use the inverter while the engine is off, we recommend that  
you start the engine every 30 to 60 minutes and let it run for approximately  
10 minutes to recharge the battery. It is also recommended that the device  
plugged into the inverter be turned OFF before starting the vehicle engine.  
6. Locate the Ground LugTerminal at the rear of the inverter. Run a wire from  
this terminal to a proper grounding point using the shortest practical length.  
It is recommended to use a minimum of 12 AWG wire.You can connect  
this wire to the chassis of your vehicle or to the grounding system in your  
boat. As an alternative, when in remote locations the ground wire can be  
connected to the earth (one way to accomplish this is to attach the wire to a  
metal rod driven into the ground). Before connecting to the ground, make  
certain that the inverter is turned off. Operation the inverter without correctly  
grounding the unit may result in electrical shock.  
Although it is not necessary to disconnect the inverter when starting the vehicle  
engine, it may momentarily cease to operate as the battery voltage decreases.  
When the inverter is not supplying power, it draws very low amperage from the  
battery. It is recommend that the inverter always be disconnected when not in  
use.  
7.Turn the inverter power switch to the ON(I) position. The LED Indicator Light  
should illuminate GREEN to confirm that power is running to the inverter.  
Note: Always disconnect the power inverter from the 12-volt power source and  
8.Turn the inverter power switch to the OFF(O) position. (The LED Indicator  
Light may “blink” briefly and/or the internal audible alarm may make a  
momentary “chirp. This is normal).  
make sure the inverter is turned OFF before replacing the fuse.  
Safety and Usage Precautions  
• For best operating results, place the inverter on a flat surface  
• Keep inverter dry. Do not expose inverter to rain or moisture.  
9. Make sure that the device you intend to operate is turned OFF. Plug the cord  
from the equipment you wish to operate into one of the AC outlets located on  
the front panel of the inverter.  
• DO NOT operate the inverter if you, the inverter, the device being operated, or  
any surface that may come into contact with the inverter are wet. Water and  
other liquids can conduct electricity, which may lead to serious injury  
or death.  
10.Turn the inverter power switch to the ON(I) position. Then turn the  
equipment on.  
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Manual  
PMP1200 Models  
• Avoid placing the inverter on or near heating vents, radiators or other  
sources of heat. Do not place or use the inverter in direct sunlight. Ideal air  
temperatures should be between 50° and 80° F.  
Television and Audio Suggestions  
Although all COLEMAN® inverters are shielded and filtered to minimize  
signal interference, some interference with your television picture may be  
unavoidable, especially with weak signals. However, here are some  
suggestions that may improve reception:  
• In order to properly disperse the heat generated from the inverter while it is  
operating, keep the inverter well ventilated. Keep the area surrounding the  
inverter clear while in use.  
• Make sure the television antenna produces a clear signal under normal  
operating conditions (at home plugged into a standard 120 volt AC outlet).  
Also, ensure that the antenna cable is properly shielded and/or good quality.  
• Do not use the inverter near flammable materials. Do not place the inverter in  
areas such as battery compartments where fumes or gases may  
accumulate.  
• Change the positions of the inverter, antenna cables and the television power  
cord.  
Inverter Protection Features  
• Isolate the television, its power cord and antenna cables from the 12-volt  
power source by running an extension cord from the inverter to the  
television set.  
Short Circuit Protection. The inverter will automatically shut down until  
short is removed.  
Low Voltage Alarm. An alarm will sound when the voltage from the battery  
discharges to 10.5 +/- 0.5 volts DC. This is an indication that the battery needs  
to be recharged.  
• Coil the television power cord and the input cables running from the 12-volt  
power source to the inverter.  
• Attach an AC interference filter or similar product between the inverter and the  
television power cord. These filters are available at most electronic supply  
stores, including Radio Shack.  
Over Voltage Protection. The RED LED Indicator Light will illuminate and  
the inverter will automatically turn itself off when the input exceeds 16.5 +/- 1  
volt DC.  
Under Voltage Protection. The RED LED Indicator Light will illuminate and  
the inverter will automatically turn itself off when the input is less than 10.0  
+/- 0.5 volts DC.  
Note: Inexpensive sound systems may emit a “buzzing” sound when  
operated with an inverter. This is due to the inadequate filters in the sound  
system. There is no solution to this problem other than purchasing a sound  
system with a higher quality power supply.  
Overload Protection. The RED LED Indicator Light will illuminate and the  
inverter will automatically turn itself off when the continuous draw of the  
equipment being operated exceeds 1200 watts or the surge draw of the  
equipment exceeds 2400 watts.  
Thermal Protection. The RED LED Indicator Light will illuminate and the  
inverter will automatically turn itself off when the circuit temperature  
exceeds 150° F.  
Notes  
The inverter is equipped with a cooling fan, which is designed to turn on when  
the unit gets hot. Automatic shut down of the unit caused by high circuit  
temperatures will occur when the cooling fan is unable to maintain a cool  
enough temperature for safe operation.  
• In the event of automatic shut down or a continuous audible alarm, turn the  
inverter power switch to the OFF(O) position until the source of the problem  
has been determined and resolved.  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Manual  
PMP1200 Models  
Troubleshooting  
Troubleshooting  
PROBLEM: Low or No Output Voltage  
Reason  
PROBLEM:TV Interference  
Reason  
Solution  
Solution  
Electrical interference from  
the inverter.  
Add an AC interference filter on  
to theTV power cord. Refer  
toTV and audio section of  
this manual.  
Poor contact with  
battery terminals.  
Clean terminals  
thoroughly. Reattach  
battery clips.  
Using incorrect type of  
voltmeter to test  
output voltage.  
Use true RMS reading meter.  
PROBLEM: Low Battery Alarm On AllTheTime  
Reason  
Solution  
Input voltage below 10.5 0.5 volts.  
Keepinputvoltageabove10.5 0.5  
volts to maintain regulation.  
PROBLEM: Red LED On  
Reason  
Solution  
Poor or weak  
Recharge or  
Battery voltage below  
10.0 0.5 volts.  
Recharge or replace battery.  
battery condition.  
replace battery.  
Inadequate power being  
delivered to the inverter  
or excessive voltage drop.  
Make sure connection is secure.  
Use lower gauge wire. Keep  
wire length as short as possible.  
Equipment being operated  
draws too much power.  
Use a higher capacity inverter  
or do not use this equipment.  
PROBLEM:TV Does Not Work  
Inverter is too hot (thermal  
shutdown mode).  
Allow inverter to cool.  
Check for adequate ventilation.  
Reduce the load on the  
inverter to rated continuous  
power output  
Reason  
Solution  
TV does not turn on.  
Try turning the inverter  
ON/OFF/ON.  
ContactTV manufacturer for  
start up surge and power  
consumption.  
Unit may be defective.  
See Warranty and call  
Customer service at  
1-888-231-4022.  
A larger inverter may  
be required.  
8
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Manual  
PMP1200 Models  
In Review  
Specifications:  
Maximum Continuous Power  
Surge Capacity (Peak Power)  
Max Power Efficiency  
Waveform  
• Never attempt to operate the inverter from any other power source other than  
a 12-volt battery.  
1200 Watts  
2400 Watts  
• When connecting and using the inverter, make sure that the inverter is  
positioned far away from any potential source of flammable fumes or gases.  
>85%  
Modified Sine Wave  
<0.8A  
• Make certain that the power consumption of the equipment you wish to  
operate is compatible with the capacity of the inverter. Do not exceed  
1200 watts in total power, or 2400 watts for each individual AC outlet.  
No Load Current Draw  
Input Voltage Range  
AC Receptacles  
11-15VDC  
• When attempting to operate battery chargers, monitor the temperature of the  
battery charger for approximately 10 minutes. If the battery charger  
becomes abnormally warm, disconnect it from the inverter immediately.  
120V AC, Grounded  
6 x 25 amp (spade type)  
6.2 lbs.  
Fuse  
• Use only 25 amp spade type fuses for the inverter.  
Weight  
• When operating the inverter with an automobile or marine battery, start the  
engine every 30 to 60 minutes and let it run for approximately 10 minutes to  
recharge the battery.  
Dimensions  
10.7” (L) x 8.4”(W) x 3.1” (H)  
271.78mm(L) x 213.36mm(W) x 78.74mm(H)  
• In the event of a continuous audible alarm or an automatic shut down of the  
unit, turn the inverter OFF immediately. Do not turn the inverter ON again  
until the source of the problem has been identified and corrected.  
Questions?  
To avoid battery drain, always disconnect the inverter when not in use.  
• Do not expose the inverter to rain or moisture.  
If you have any questions about this product, please contact our Customer  
Service Department at (888) 231-4022, Monday through Friday, 9 AM to 5 PM  
• Avoid placing the inverter near sources of heat or in direct sunlight.  
• While in use, make sure that the inverter is properly ventilated.  
• For best operating results, make sure the unit is placed on a flat surface.  
9
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson Network Router 536v6 User Manual
Technicolor Thomson Stereo System MS4200 User Manual
Teledyne Tablet Accessory T803 User Manual
TP Link Network Router TR 966D User Manual
Transition Networks Switch SUBTF10XX 1XX MX User Manual
TRENDnet Headphones TVP SP1BK User Manual
Tripp Lite Computer Monitor SUPDU001 User Manual
Troy Bilt Trimmer TB22 EC User Manual
Turbosound Portable Speaker TCS SERIES USER User Manual
Tyco Network Card S610s User Manual