Sun Microsystems Computer Drive VSM GUI User Manual

Sun StorageTek™  
VSM GUI  
Getting Started Guide  
312651601  
Rev A  
Version 6.2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sun StorageTek™ VSM GUI  
Getting Started Guide  
Version 6.2.0  
Sun Microsystems, Inc.  
Part No. 312651601  
July 2007, Revision A  
Submit comments about this document at: http://www.sun.com/hwdocs/feedback  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright © 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.  
U.S. Government Rights - Commercial software. Government users are subject to the Sun Microsystems, Inc. standard license  
agreement and applicable provisions of the FAR and its supplements.  
Use is subject to license terms.  
This distribution may include materials developed by third parties.  
Sun, Sun Microsystems, the Sun logo, Sun StorageTek and StorageTek are trademarks or registered trademarks of Sun Microsystems,  
Inc. in the U.S. and other countries.  
This product uses the mozXPath JavaScript code created by [email protected]. The mozXPath is available under the Creative  
Commons Attribution-ShareAlike License.  
This product uses the tigra menu JavaScript code created by Soft Complex. The tigra menu is available under the Soft Complex license  
and royalty terms and conditions.  
This product uses the IFRAME scroller DHTML scripts code created by Dynamic Drive. The IFRAME scroller is available under the  
Dynamic Drive DHTML scripts- Terms of Use.  
This product is covered and controlled by U.S. Export Control laws and may be subject to the export or import laws in other countries.  
Nuclear, missile, chemical biological weapons or nuclear maritime end uses or end users, whether direct or indirect, are strictly  
prohibited. Export or reexport to countries subject to U.S. embargo or to entities identified on U.S. export exclusion lists, including, but  
not limited to, the denied persons and specially designated nationals lists is strictly prohibited.  
Copyright © 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.  
L'utilisation est soumise aux termes de la Licence.  
Cette distribution peut comprendre des composants développés par des tierces parties.  
Sun, Sun Microsystems, le logo Sun, Sun StorageTek et StorageTek sont des marques de fabrique ou des marques déposées de Sun  
Microsystems, Inc. aux Etats-Unis et dans d'autres pays.  
Ce produit emploie le code de mozXPath JavaScript cree par [email protected] et est disponible sous le Creative Commons  
Attribution-ShareAlike License.  
Ce produit emploie le code de tigra menu JavaScript cree par Soft Complex et est disponible sous le Soft Complex license and royalty  
terms and conditions.  
Ce produit emploie le code de IFRAME scroller DHTML scripts cree par Dynamic Drive et est disponible sous le Dynamic Drive  
DHTML scripts- Terms of Use.  
Ce produit est soumis à la législation américaine en matière de contrôle des exportations et peut être soumis à la règlementation en  
vigueur dans d'autres pays dans le domaine des exportations et importations. Les utilisations, ou utilisateurs finaux, pour des armes  
nucléaires,des missiles, des armes biologiques et chimiques ou du nucléaire maritime, directement ou indirectement, sont strictement  
interdites. Les exportations ou réexportations vers les pays sous embargo américain, ou vers des entités figurant sur les listes  
d'exclusion d'exportation américaines, y compris, mais de manière non exhaustive, la liste de personnes qui font objet d'un ordre de ne  
pas participer, d'une façon directe ou indirecte, aux exportations des produits ou des services qui sont régis par la législation  
américaine en matière de contrôle des exportations et la liste de ressortissants spécifiquement désignés, sont rigoureusement  
interdites.  
We welcome your feedback. Please contact the Sun Learning Services Feedback System at:  
or  
Sun Learning Services  
Sun Microsystems, Inc.  
One StorageTek Drive  
Louisville, CO 80028-3256  
USA  
Please include the publication name, part number, and edition number in your correspondence if they are  
available. This will expedite our response.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision History  
Short  
Name  
EC  
Part Number  
Rev  
Date  
Comments  
VSM GUI 132812 312651601  
Rev A July 2007  
VSM GUI 6.2.0 Getting Started Guide  
312651601 • Rev A  
Revision History iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
VSM GUI Home Page  
2
JCL to Unload the VSM GUI 6.2.0 SMP/E JCL 12  
JCL to Unload the VSM GUI Service Tape SMP/E JCL 31  
312651601 • Rev A  
List of Figures vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
VSM GUI Installation Summary and Checklist  
3
VSM GUI PC Hardware Requirements  
VSM GUI Software Requirements  
VSM GUI 6.2.0 Product Installation Tape Contents  
4
4
5
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
SMP/E Target Library Contents 15  
6
SMP/E Distribution Library Contents 17  
VSM GUI Authorization Levels and Commands 21  
File Names for VSM GUI Service Tapes 30  
312651601 • Rev A  
List of Tables ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
x
VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
The Virtual Storage Manager Graphical User Interface (VSM GUI) is a Web-based GUI  
which communicates with the Sun StorageTek MVS HTTP server to provide a point-  
and-click alternative interface to the mainframe VTCS commands and utilities.  
Audience  
This guide is for Sun StorageTek or customer personnel who are responsible for  
installing and configuring the VSM GUI.  
Prerequisites  
To perform the tasks described in this guide, you should already understand the  
following:  
MVS or OS/390 operating system  
JES2 or JES3  
System Modification Program Extended (SMP/E)  
Nearline Control Solution (NCS)  
Virtual Tape Control System (VTCS)  
PC hardware, operating systems, and Internet browsers.  
What’s New in this Release  
VSM GUI 6.2.0 is graphical interface that supports all VTCS 6.0, 6.1, and 6.2 commands  
and functions. No other VTCS releases are supported. Refer to the VTCS 6.0, 6.1, and  
6.2 documentation for details about “what’s new” for a specific release of VTCS.  
312651601 • Rev A  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
How this Guide is Organized  
This guide contains the following sections:  
Additional Information  
Sun Microsystems, Inc. (Sun) offers several methods for you to obtain additional  
information.  
Sun’s External Web Site  
Sun’s external Web site provides marketing, product, event, corporate, and service  
information. The external Web site is accessible to anyone with a Web browser and  
an Internet connection.  
The URL for the Sun external Web site is: http://www.sun.com  
The URL for Sun StorageTek brand-specific information is:  
Customer Resource Center  
The Sun StorageTek product Customer Resource Center (CRC) is a Web site that  
enables members to resolve technical issues by searching code fixes and technical  
documentation for StorageTek brand products. CRC membership entitles you to  
other proactive services, such as HIPER subscriptions, technical tips, answers to  
frequently asked questions, addenda to product documentation books, and online  
product support contact information.  
xii VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Customers who have a current warranty or a current maintenance service agreement  
may apply for membership by clicking on the Request Password button on the CRC  
home page. Sun employees may enter the CRC through the SunWeb PowerPort.  
Partners Site  
The StorageTek Partners site is a Web site for partners with a StorageTek Partner  
Agreement. This site provides information about products, services, customer support,  
upcoming events, training programs, and sales tools to support StorageTek Partners.  
Access to this site, beyond the Partners Login page, is restricted. On the Partners Login  
page, Sun employees and current partners who do not have access can request a login  
ID and password and prospective partners can apply to become StorageTek resellers.  
The URL for the StorageTek Partners site is: http://members.storagetek.com  
The URL for partners with a Sun Partner Agreement is:  
Third-Party Web Sites  
Sun is not responsible for the availability of third-party web sites mentioned in this  
document. Sun does not endorse and is not responsible or liable for any content,  
advertising, products, or other materials that are available on or through such sites or  
resources. Sun will not be responsible or liable for any actual or alleged damage or loss  
caused by or in connection with the use of or reliance on any such content, goods, or  
services that are available on or through such sites or resources.  
Hardcopy Publications  
Contact a Sun sales or marketing representative to order additional paper copies of this  
publication or to order other StorageTek brand product customer publications in paper  
format.  
Customer Support  
Customer support is available 24 hours a day, seven days a week, to customers with  
Sun or StorageTek maintenance contracts and to Sun employees. You can find  
additional information about customer support on the Customer Resource Center  
312651601 • Rev A  
Preface xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Customer-initiated Maintenance  
Customer-initiated maintenance begins with a telephone call from you to Sun  
Microsystems StorageTek Support. You receive immediate attention from qualified  
personnel, who record problem information and respond with the appropriate level of  
support.  
To contact Sun Microsystems StorageTek Support about a  
problem:  
1. Use the telephone and call:  
800.872.4786 (1.800.USA.4Sun)  
800.722.4786 (Canada)  
For international locations, go to  
for the appropriate telephone number  
2. Describe the problem to the call taker. The call taker will ask several questions and  
will either route your call to or dispatch a support representative.  
If you have the following information when you place a service call, the process will be  
much easier:  
Account name  
Site location number  
Contact name  
Telephone number  
Equipment model number  
Device address  
Device serial number (if known)  
Urgency of problem  
Fault Symptom Code (FSC)  
Problem description  
Sun’s Worldwide Offices  
You may contact any of Sun’s worldwide offices to discuss complete storage, service,  
and support solutions for your organization. You can find address and telephone  
number information on Sun’s external Web site at:  
xiv VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Related Publications  
The following publications provide additional information about VSM and Sun  
StorageTek Automated Cartridge System software and hardware.  
NCS/VTCS  
Introducing VSM  
NCS/VTCS XML Guide  
NCS Installation Guide  
VTCS and VSM  
The VTCS and VSM documentation set consists of the following:  
Installing and Configuring VTCS  
Managing VTCS  
Beyond the Basics: VTCS Leading Edge Techniques  
VTCS Command and Utility Reference  
VTCS Messages and Codes  
VTCS Quick Reference  
The VTCS Information CD-ROM, containing PDF file formats of the preceding  
publications  
VTSS  
Virtual Storage Manager Planning, Implementation, and Usage Guide  
Virtual Storage Manager Physical Planning Guide  
VTSS Installation Guide  
HSC  
Configuration Guide  
Operators Guide  
System Programmers Guide  
Messages and Codes  
System Programmers Reference Summary  
Operators Reference Summary  
312651601 • Rev A  
Preface xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
xvi VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
CHAPTER  
What is the VSM GUI?  
The VSM GUI is a Web-based tool that lets you “point and click” instead of entering  
VTCS commands or running VTCS utilities. The VSM GUI consists of a World Wide  
Web (WWW) application and a web server to provide network connectivity for WWW  
browsers. The server component is a multitasking MVS HTTP content server that runs  
as an MVS started task.  
The VSM GUI 6.2.0 supports all VTCS 6.0.0, 6.1.0 and 6.2.0 commands and utilities,  
including the CONFIG utility. It does not support the standalone RTV utility or the  
HSC commands and utilities.  
The VSM GUI also lets you drive VTCS functions from the output of a command or  
utility. For example, you can run an MVC or VTV report, sort it by any column, then  
run VTCS operations against a selected MVC or VTV.  
Similarly, you can run Query RTD, then right click on any of the RTDs listed on the  
response to bring up a menu that displays the Audit, Config, Decom, Query Config,  
Query RTD, and Vary RTD commands. You can then select a command and a web  
page for that command appears with the RTD field filled in with information for the  
RTD you selected.  
FIGURE 1-1 shows the VSM GUI home page.  
312651601 • Rev A  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
FIGURE 1-1 VSM GUI Home Page  
2
VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
CHAPTER  
Installing and Configuring the VSM  
GUI  
To plan and verify completion of the installation, use the checklist below.  
VSM GUI Installation Summary and  
Checklist  
Use the checklist in TABLE 2-1 to help plan and complete your VSM GUI installation and  
configuration tasks.  
TABLE 2-1  
Task  
VSM GUI Installation Summary and Checklist  
Mark when Completed  
312651601 • Rev A  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Verify VSM GUI Hardware Prerequisites  
Verify the VSM GUI PC hardware requirements in TABLE 2-2.  
TABLE 2-2  
VSM GUI PC Hardware Requirements  
Hardware Description Minimum Requirement  
Recommended System  
System unit  
Pentium III, 512MB of memory, 256 colors, mouse Pentium IV, 1024MB of memory,  
64K colors, mouse  
CD-ROM drive  
Monitor  
present  
present  
1024 x 768 pixels with 256 colors  
present  
1280 x 1024 pixels with 64K colors  
present  
network card  
Verify VSM GUI Software Prerequisites  
Verify the VSM GUI PC software requirements in TABLE 2-3.  
TABLE 2-3  
Software  
VSM GUI Software Requirements  
Description  
PC Windowing System  
Microsoft Windows XP or newer  
PC TCP/IP for communications between the VSM GUI The 32-bit WINSOCK TCP/IP supplied with the  
PC component and the MVS HTTP server  
Windows versions listed above is required to enable the  
GUI to transfer configuration data between the  
workstation and the mainframe. Customers can also  
transfer configuration data using other facilities  
(external to the GUI) if desired.  
Web Browser  
VTCS  
Microsoft Internet Explorer V6.x or later or  
Mozilla/FireFox 1.4 or higher  
VTCS 6.0.0, 6.1.0 or 6.2.0 and prerequisites  
Verify Installation Materials  
VSM GUI is delivered on a product installation tape or on a CD-ROM. Before  
attempting to install VSM GUI, make sure you have the VSM GUI 6.2.0 product  
installation tape or CD-ROM.  
4
VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                           
Load VSM GUI from Tape or CD-ROM  
Media  
The installation process is the same for each media except for the actual loading of the  
software from the product installation tape or CD-ROM:  
Tape: Follow the instructions below to load and SMP/E install VSM GUI.  
CD-ROM: Insert the CD-ROM and open the file named “Start here.html” for  
procedures that load the VSM GUI files from the CD-ROM and then refer you back  
to this chapter to continue the SMP/E installation.  
Product Installation Tape Contents  
TABLE 2-4 lists the files included on the VSM GUI 6.2.0 product installation tape.  
TABLE 2-4  
VSM GUI 6.2.0 Product Installation Tape Contents  
File  
1
Data Set Name  
SMPMCS  
Description  
VSM GUI SMP/E control statements  
HTTPD server JCLIN  
HTTPD load modules  
HTTPD STKSAMP  
2
SSKY500.F1  
SSKY500.F2  
SSKY500.F3  
SSKY500.F4  
ASAR700.F1  
ASAR700.F2  
ASAR700.F3  
ASAR700.F4  
ASAR700.F5  
SSKU620.F1  
SSKU620.F2  
SSKU620.F3  
SSKU620.F4  
SSKU620.F5  
SSKU620.F6  
SSKU620.F7  
SSKU620.F8  
SSKU620.F9  
3
4
5
HTTPD icons  
6
SAS/C component JCLIN  
SAS/C linked LMODs  
SAS/C linked LMODs  
SAS/C linked LMODS  
SAS/C transient LMODs  
VSM GUI www JCLIN  
VSM GUI LMODs  
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
TABLE 2-4  
File  
20  
VSM GUI 6.2.0 Product Installation Tape Contents  
Data Set Name  
SSKU620.F10  
SSKU620.F11  
SSKU620.F12  
SSKU620.F13  
SSKU620.F14  
SSKU620.F15  
SSKU620.F16  
SSKU620.F17  
SSKU620.F18  
SSKU620.F19  
SSKU620.F20  
SSKU620.F21  
PTF.F1  
Description  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI www modules  
VSM GUI translations  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
VSM GUI STK samples  
PTFs for HTTPD and SAS/C (required)  
HTTPD installation JCL (optional)  
32  
33  
SMPE.JCL  
Note – The VSM GUI installation automatically installs the VSM GUI sample jobs in  
the VSM GUI STKSAMP.  
Product Installation CD-ROM Contents  
TABLE 2-5 lists the files included on the VSM GUI 6.2.0 product installation CD-ROM.  
TABLE 2-5  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
Directory  
File Name  
Description  
/cdrom  
Start Here.html  
VGUI62.pax  
VGUI62logo.png  
fromlocal.html  
fromnts.html  
loadsamp.html  
notices.html  
troubles.html  
chgit.html  
CD-ROM installation Web file  
MPNTS binary file  
/cdrom  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
6
VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
TABLE 2-5  
Directory  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
File Name  
Description  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Documents  
/cdrom/Samples  
fromnetwork.html  
index.html  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
CD-ROM installation Web file  
logoab8.gif  
pax.html  
@@NOTES.samp  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
/cdrom/Samples  
@SKUEDIT.samp  
C1CSIBLD.samp  
C3DDDEFS.samp  
I2ALLOC.samp  
I4RCV.samp  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
I6APPLY.samp  
I8ACCEPT.samp  
LOADSAMP.samp  
NTSVGUI.samp  
U1RCV.samp  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
U3ACCEPT.samp  
V2APPLY.samp  
@@TOC.samp  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
@SKURUN.samp  
C2ZONES.samp  
I1DDDEFS.samp  
I3ALLOC.samp  
I5RCV.samp  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
UNIX text file representation of  
sample JCL member  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 2-5  
Directory  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
File Name  
Description  
/cdrom/Samples  
I7APPLY.samp  
I9ACCEPT.samp  
NETVGUI.samp  
S1COPY.samp  
U2APPLY.samp  
V1RCV.samp  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples  
V3ACCEPT.samp  
@@NOTES.samp  
@SKUEDIT.samp  
C1CSIBLD.samp  
C3DDDEFS.samp  
I2ALLOC.samp  
I4RCV.samp  
UNIX text file representation of  
sample JCL member  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
I6APPLY.samp  
I8ACCEPT.samp  
NETVGUI.samp  
S1COPY.samp  
U2APPLY.samp  
V1RCV.samp  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
V3ACCEPT.samp  
@@TOC.samp  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
@SKURUN.samp  
DOS text file representation of  
sample JCL member  
8
VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 2-5  
Directory  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
File Name  
Description  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
/cdrom/Samples.win  
C2ZONES.samp  
I1DDDEFS.samp  
I3ALLOC.samp  
I5RCV.samp  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
I7APPLY.samp  
I9ACCEPT.samp  
NTSVGUI.samp  
U1RCV.samp  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
U3ACCEPT.samp  
V2APPLY.samp  
DOS text file representation of  
sample JCL member  
DOS text file representation of  
sample JCL member  
/cdrom/VGUI62.gimzip  
GIMPAF.XML  
SMPNTS control file  
/cdrom/VGUI62.gimzip  
GIMPAF.XSL  
SMPNTS control file  
/cdrom/VGUI62.gimzip  
SMPHOLD  
SMPNTS control file  
/cdrom/VGUI62.gimzip  
SMPPTFIN  
SMPNTS control file  
/cdrom/VGUI62.gimzip  
SMPRELF  
SMPNTS control file  
Storage.Tek0001.EMPTY.F80.pax.Z  
Storage.Tek0002.ASAR700.SMPPTFIN.pax.Z  
/cdrom/VGUI62.gimzip/SMPHOLD  
/cdrom/VGUI62.gimzip/SMPPTFIN  
SMPNTS binary file of SMPHOLD  
SMPNTS binary file of SAS/C  
control statements  
Storage.Tek0035.L1K0001.SMPPTFIN.pax.Z  
Storage.Tek0038.L1K0004.SMPPTFIN.pax.Z  
Storage.Tek0041.L1S0001.SMPPTFIN.pax.Z  
Storage.Tek0008.SSKU620.SMPPTFIN.pax.Z  
Storage.Tek0036.L1K0002.SMPPTFIN.pax.Z  
Storage.Tek0039.L1K0005.SMPPTFIN.pax.Z  
Storage.Tek0030.SSKY500.SMPPTFIN.pax.Z  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
SMPNTS binary file of HTTPD  
PTF control statements  
SMPNTS binary file of HTTPD  
PTF control statements  
SMPNTS binary file of SAS/C PTF  
control statements  
SMPNTS binary file of VSM GUI  
control statements  
SMPNTS binary file of HTTPD  
PTF control statements  
SMPNTS binary file of HTTPD  
PTF control statements  
SMPNTS binary file of HTTPD  
control statements  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 2-5  
Directory  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
File Name  
Description  
Storage.Tek0037.L1K0003.SMPPTFIN.pax.Z  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPPTFIN  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
SMPNTS binary file of HTTPD  
PTF control statements  
Storage.Tek0040.L1K0006.SMPPTFIN.pax.Z  
Storage.Tek.SSKY500.F1.pax.Z  
Storage.Tek.SSKY500.F2.pax.Z  
Storage.Tek.SSKY500.F3.pax.Z  
Storage.Tek.SSKY500.F4.pax.Z  
Storage.Tek.ASAR700.F1.pax.Z  
Storage.Tek.ASAR700.F2.pax.Z  
Storage.Tek.ASAR700.F3.pax.Z  
Storage.Tek.ASAR700.F4.pax.Z  
Storage.Tek.ASAR700.F5.pax.Z  
Storage.Tek.SSKU620.F1.pax.Z  
Storage.Tek.SSKU620.F2.pax.Z  
Storage.Tek.SSKU620.F3.pax.Z  
Storage.Tek.SSKU620.F4.pax.Z  
Storage.Tek.SSKU620.F5.pax.Z  
Storage.Tek.SSKU620.F6.pax.Z  
Storage.Tek.SSKU620.F7.pax.Z  
Storage.Tek.SSKU620.F8.pax.Z  
Storage.Tek.SSKU620.F9.pax.Z  
Storage.Tek.SSKU620.F10.pax.Z  
Storage.Tek.SSKU620.F11.pax.Z  
SMPNTS binary file of HTTPD  
PTF control statements  
SMPNTS binary file of HTTPD  
server JCLIN  
SMPNTS binary file of HTTPD  
load modules  
SMPNTS binary file of HTTPD  
STKSAMP  
SMPNTS binary file of HTTPD  
icons  
SMPNTS binary file of SAS/C  
component JCLIN  
SMPNTS binary file of SAS/C  
linked LMODs  
SMPNTS binary file of SAS/C  
linked LMODs  
SMPNTS binary file of SAS/C  
linked LMODs  
SMPNTS binary file of SAS/C  
transient LMODs  
SMPNTS binary file of VSM GUI  
www JCLIN  
SMPNTS binary file of VSM GUI  
load modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
10 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 2-5  
Directory  
VSM GUI 6.2.0 Product Installation CD-ROM Contents  
File Name  
Description  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
/cdrom/VGUI62.gimzip/SMPRELF  
Storage.Tek.SSKU620.F12.pax.Z  
Storage.Tek.SSKU620.F13.pax.Z  
Storage.Tek.SSKU620.F14.pax.Z  
Storage.Tek.SSKU620.F15.pax.Z  
Storage.Tek.SSKU620.F16.pax.Z  
Storage.Tek.SSKU620.F17.pax.Z  
Storage.Tek.SSKU620.F18.pax.Z  
Storage.Tek.SSKU620.F19.pax.Z  
Storage.Tek.SSKU620.F20.pax.Z  
Storage.Tek.SSKU620.F21.pax.Z  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
SMPNTS binary file of VSM GUI  
www modules  
Note – The VSM GUI installation automatically installs the VSM GUI sample jobs in  
the VSM GUI STKSAMP.  
VSM GUI FMIDs  
The VSM GUI software and selected components of the SAS/C runtime library are  
packaged in standard SMP/E format. The VSM GUI 6.2.0 product installation media  
includes the following FMIDs:  
SSKY500 - HTTPD server base function  
SSKU620 - VSM GUI base function  
ASAR700 - SAS/C selected components base function  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Unload the VSM GUI SMP/E JCL Data Set  
Unloading VSM GUI SMP/E JCL Data Set from  
Tape  
The VSM GUI SMP/E JCL Data Set contains sample JCL members for the VSM GUI; see  
TABLE 2-4 for more information. Use the JCL in FIGURE 2-1 to create a copy of the SMP/E  
JCL from file 33 of the product installation tape to help install the VSM GUI.  
jobcard JOB 'accounting information'  
//*  
//*  
//*  
//*  
//LOAD  
LOAD PDS FROM UNLOADED DATASET  
EXEC PGM=IEBCOPY  
//SYSUT3 DD UNIT=VIO,SPACE=(CYL,(20,3))  
//IN1  
//  
DD DSN=SMPE.JCL,DISP=(OLD,KEEP),  
UNIT=3480,  
//  
//OUT1  
//  
LABEL=(33,SL,EXPDT=98000),VOL=SER=SKUnnn  
DD DSN=hlq.SMPEJCL,DISP=(,CATLG),  
UNIT=SYSDA,  
//  
SPACE=(TRK,(10,2,10)),  
//  
DCB=(RECFM=FB,LRECL=80,BLKSIZE=23440)  
//SYSPRINT DD SYSOUT=*  
//SYSIN DD *  
COPY OUTDD=OUT1,INDD=IN1  
//  
FIGURE 2-1 JCL to Unload the VSM GUI 6.2.0 SMP/E JCL  
Unloading VSM GUI SMP/E JCL Data Set from  
CD-ROM  
The VSM GUI SMP/E JCL Data Set contains sample JCL members for the VSM GUI.  
Follow the instructions in the file named “Start here.html” on the CD-ROM to  
transfer the VGUI JCL Samples file using one of the following three methods:  
CD-ROM on FTP server and ICSF available  
Receive FROMNETWORK  
Note: This also works without ICSF if SMP/E is at v3r4.0 or better and the Java  
SHA-1 support is available.  
12 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
ICSF available; CD-ROM not on FTP server  
Receive from Local Host  
ICSF not available  
Receive from NTS  
Set Up the SMP/E Environment and  
Install the Software  
Caution – Do not install the VSM GUI and its supporting SAS/C functions in an  
SMP/E CSI containing other Sun StorageTek products with SAS/C functions you want  
to preserve. Otherwise, unpredictable results may occur.  
However, if you already have ExPR installed: The VSM GUI should be installed in the  
same SMP/E CSI so as to share the HTTPD server (the HTTPD server and SAS/C  
runtime library files are the same on both tapes). SMP/E will determine what needs to  
be installed.  
Caution – VSM GUI version 6.2 cannot coexist with previous VSM GUI versions in the  
same SMP/E CSI because of data set conflicts.  
Caution – Co-existing with ExPR GUI for the same SMP/E environment will require  
the relevant ExPR GUI maintenance patches (PTF) for the HTTPD server base function  
and SAS/C function.  
Caution – The High Level Qualifiers you will use for the SMP/E data set is restricted  
to no more than 23 characters. This is to ensure that all the data sets received for the  
product will comply with the 44 character maximum length data set name, imposed by  
the operating system.  
The SMP/E JCL Data Set contains jobs to create the SMP/E environment (allocating  
data sets, setting SMP/E options, and so forth) in addition to the SMP/E RECEIVE,  
APPLY and ACCEPT jobs.  
For more information, see the following members:  
@@NOTES - General notes on installation process  
@@TOC - Table of contents for the members  
Each job also contains usage notes that describe what needs to be changed.  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
To set up the SMP/E environment and install the software:  
1. Customize the installation jobs.  
You can do this manually with an editor, but it is recommended that you use the  
provided ISPF edit macro @SKUEDIT and @SKURUN REXX exec for automated updates of  
an individual member or all members.  
Before use, first copy these two members to a library in your SYSPROC concatenation,  
then change the job settings in @SKUEDIT to the appropriate settings for the site. Then  
to update a member just invoke @SKUEDITwithin the member or to change all members,  
from TSO or ISPF Option 6, enter:  
@SKURUN smpejcl_dataset_name @SKUEDIT  
@SKUEDIT contains information describing its use.  
2. Build the SMP/E database.  
Run the following customized members:  
C1CSIBLD - Allocate and initialize the SMP/E data sets.  
C2ZONES - Define and update each zone.  
C3DDDEFS - Define the required DDDEFs for each zone.  
This job may end with return code 4.  
SMP/E warning code of GIM27701W is normal and expected for new SMP/E  
environments where there is no definition yet defined. The SMP/E Replace command  
will be changed to an Add command automatically.  
3. Define DDDEFs and allocate the target and distribution data sets.  
Run the following customized members:  
I1DDDEFS - Define the DDDEFs.  
This job may end with return code 4.  
SMP/E warning code of GIM27701W is normal and expected for new SMP/E  
environments where there is no definition yet defined. The SMP/E Replace  
command will be changed to an Add command automatically.  
I2ALLOC - Allocate the HTTPD target and distribution data sets.  
Do not run this job if you already have the HTTPD server installed (e.g., as part of  
the ExPR GUI).  
I3ALLOC - Allocate VSM GUI Web content target and distribution data sets.  
4. Run the following as required for your installation media:  
TAPE ONLY: Run customized member I4RCV to RECEIVE the HTTPD, SAS/C and  
VSM GUI FMIDs.  
Modify this job to exclude the SSKY500 and ASAR700 FMIDs if you already have the  
HTTPD server and SAS/C run time received in your SMP/E environment.  
CD-ROM ONLY: Run customized member NETVGUI to RECIEVE from a network-  
mounted CD-ROM the HTTPD, SAS/C, required PTFs for HTTPD and SAS/C and  
VSM GUI FMIDs.  
Modify this job to exclude the SSKY500 and ASAR700 FMIDs if you already have the  
HTTPD server and SAS/C run time received in your SMP/E environment.  
Modify this job to exclude the PTFs already applied in your SMP/E environment.  
14 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CD-ROM ONLY: Run customized member NTSVGUI to RECIEVE from an SMPNTS  
hierarchy the HTTPD, SAS/C, required PTFs for HTTPD and SAS/C and VSM GUI  
FMIDs.  
Modify this job to exclude the SSKY500 and ASAR700 FMIDs if you already have the  
HTTPD server and SAS/C run time received in your SMP/E environment.  
Modify this job to exclude the PTFs already applied in your SMP/E environment.  
5. TAPE ONLY: Run customized member I5RCV to RECEIVE the PTFs required for  
HTTPD and SAS/C FMIDs.  
Do not run this job if you already have the required PTFs already applied in your  
SMP/E environment.  
6. Run customized member I6APPLY to APPLY the HTTPD server and SAS/C FMIDs  
and required PTFs.  
Modify this job if you already have the HTTPD server and SAS/C run time applied in  
your SMP/E environment but do not have the required PTFs.  
Do not run this job if you already have the required PTFs already applied in your  
SMP/E environment.  
Notes:  
By default this job will fail with return code 12, due to STOP instructions in the PTFs  
due to DELETE statements in the SMP/E commands. You will need to modify the  
job to allow the PTF DELETE commands to be processed with a BYPASS statement.  
This job will end with return code 4.  
SMP/E warning code of GIM24701W is normal and expected due to the LINK-EDIT  
parameters not obtained and using defaults.  
SMP/E warning code of GIM42001W is normal and expected due to BYPASS  
instruction in the SMP/E statement.  
7. Run customized member I7APPLY to APPLY the VSM GUI FMID.  
This job will end with return code 4.  
SMP/E warning code of GIM23904W and GIM23903W is normal and expected due to  
the LINK-EDIT reporting incomplete load modules. These modules will get resolved by  
the HTTPD at run time.  
When the APPLY is successful, the SMP/E target libraries contain the following data  
sets:  
TABLE 2-6  
SMP/E Target Library Contents  
Data Set Name  
Contents  
HTTPDCMN.ICONS  
SSAROMOD  
SSARRTNS  
server icons  
SAS/C LMODs  
run time libraries  
FCD LMODs  
SSKRRTNS  
SSKYRTNS  
FCD LMODs  
STKLOAD  
load modules  
HTTPD sample material  
STKSAMP  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
TABLE 2-6  
SMP/E Target Library Contents  
Data Set Name  
ENSAMP  
TRANS  
Contents  
VSM GUI sample material  
web content file translations  
web content  
VSM.EN.ABOUT  
VSM.COMMS  
web content  
VSM.COMMS.W3C  
VSM.EN.CONFIG  
web content  
web content  
VSM.EN.CONFIG.W3C  
VSM.EN.DOCS  
web content  
web content  
VSM.EN.DOCS.WHDATA  
VSM.EN.DOCS.WHGDATA  
VSM.EN.DOCS.WHXDATA  
VSM.EN.HOME  
web content  
web content  
web content  
web content  
VSM.EN.IMAGES  
web content  
VSM.EN.REPORTS  
VSM.EN.REPORTS.W3C  
VSM.EN.SCRIPTS  
web content  
web content  
web content  
VSM.EN.TEMPLAT  
VSM.EN.UTILS  
web content  
web content  
VSM.EN.UTILS.W3C  
web content  
8. Run customized member I8ACCEPT to ACCEPT the HTTPD server and SAS/C  
FMIDs and required PTFs.  
Notes:  
By default this job will fail with return code 12, due to STOP instructions in the PTFs  
due to DELETE statements in the SMP/E commands. You will need to modify the  
job to allow the PTF DELETE commands to be processed with a BYPASS statement.  
This job will end with return code 4.  
SMP/E warning code of GIM24701W is normal and expected due to the LINK-EDIT  
parameters not obtained and using defaults.  
SMP/E warning code of GIM42001W is normal and expected due to BYPASS  
instruction in the SMP/E statement.  
SMP/E warning code of GIM61903W is normal and expected due to the previous  
APPLY statements having removed load modules from the DLIB.  
16 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Run customized member I9ACCEPT to ACCEPT the VSM GUI FMID.  
When the ACCEPT is successful, the SMP/E distribution libraries contain the following  
data sets:  
TABLE 2-7  
SMP/E Distribution Library Contents  
Data Set Name  
AENABT  
Contents  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
web content  
VSM GUI sample material  
LMODs  
AENCFG  
AENCFGW  
AENCMS  
AENCMSW  
AENDOC  
AENDOW  
AENDOG  
AENDOX  
AENHME  
AENIMG  
AENRPT  
AENRPTW  
AENSCP  
AENTPL  
AENUTL  
AENUTLW  
ASAMP  
ASAROBM  
ASAROMM  
ASAROSM  
ASARRTNS  
ASKURTNS  
ASKYICNS  
ASKYRTNS  
ASKYSAMP  
ATRANS  
LMODs  
LMOD  
load modules  
LMODs  
server icons  
LMODs  
HTTPD sample material  
web content file translations  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
10. Run the customized member S1COPY to copy the customizable members to a non-  
SMP/E controlled data set.  
Important: You must modify the S1COPY JCL line that contains step "//IN1" for the  
DSN parameter. Change the default sample data set STKSAMP to the VSM GUI sample  
data set ENSAMP.  
When the copy has successfully completed, there will be a new data set, STKPARM, to  
which you can apply your site customization. Refer to the data set members SKUPROC  
and SKUPRM00 for sample templates to use.  
APF Authorize the VSM GUI Libraries  
In addition to the NCS libraries, APF authorize the VSM GUI load library STKLOADand  
the SSARRTNS library by any of the following methods:  
Dynamically authorize the load library by using the MVS SETPROG APF,ADD,DSNAME  
operator command.  
Dynamically authorize the load library by:  
Adding the load library to the MVS parameter library PROGxx member. For  
example:  
SYS1.PARMLIB(PROG00)  
Issuing the MVS SET PROG=xx operator command.  
(Recommended) Permanently authorize the load library by:  
Adding the VSM GUI load libraries to the MVS parameter library members  
IEAAPFxx or PROGxx. For example:  
SYS1.PARMLIB(IEAAPF00)  
OR  
SYS1.PARMLIB(PROG00)  
IPLing the system.  
Customize the VSM GUI Startup Proc  
To create the VSM GUI startup procedure, modify STKPARM member SKUPROC as  
described in the JCL comments and add the procedure to the production PROCLIB.  
Caution – The VSM GUI startup procedure must specify the active HSC CDS,  
otherwise the active CDS can be updated with incorrect values from the secondary or  
standby CDS.  
18 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Customize the VSM GUI Parameter File  
The VSM GUI sample startup proc SKUPROC calls the sample parameter file SKUPRM00  
from the STKPARMdata set. See the following sections for more information and modify  
the values in SKUPRM00 for your site’s needs from the STKPARM data set.  
The HTTP server parameter file is formatted with one parameter setting per line,  
continuation onto following lines is not supported. Comment lines start with a hash  
character (#).  
VSM GUI Server Configuration Parameters  
gmtoffset offset  
The system clock offset from GMT. Required if the system clock not set to GMT. You  
can specify the offset in hours, minutes, and seconds. For example, 10 hours 30  
minutes specifies ten and a half hours ahead of GMT.  
loglevel level  
The logging message level. Valid values are error, warning, info, and the default is  
warning. For example, if you specify info, you log only information messages. If  
you specify error, you log error, warning, and information messages.  
serverbase hlq  
The high level qualifier of the server data sets in the form hlq. This should be the  
same as the hlq used during the SMP/E install. This parameter is required.  
VSM_AUDIT state  
Determine if VTCS commands issued using the GUI will be displayed in the HTTP  
server log file for audit purposes. Valid values are YES for auditing or any other  
string for no auditing. Default is no auditing.  
Audit lines in the log will begin with the string: VSMGUI AUDIT.  
VARY_TIME seconds  
Determine the period of time to wait after a VARY RTD or VARY CLINK command  
has been issued before displaying the status of the varied device. Default value is 60  
seconds.  
Network Parameters  
servername name  
The server name reported in responses. The default is the network host name.  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
serverdomain domain  
The server domain name reported in responses; for example, yourcompany.com.  
The default is all blanks.  
port pppp  
The IP network port the server listens on for connections. The default is port 80, the  
standard HTTP port.  
The effective IP network port must be accessible for use by the server and it must not  
be reserved for use by another jobname (that is, by the TCP/IP PORT or  
PORTRANGE configuration statements).  
Also under OS/390 or z/OS, the server started task requires SAF authority to  
interface with TCP/IP or initialization errors will occur For example, use the  
following procedure for RACF:  
1. Create a RACF group with an OMVS segment and GID for the server started task:  
RDEFINE STARTED http.* STDATA(USER(userid) GROUP(groupname)) ADDGROUP  
groupname OMVS(GID(groupid))  
where:  
http is the name of the server started task procedure/  
userid is the RACF userid to be associated with the started task.  
groupname is the RACF group associated  
2. Create a RACF userid with an OMVS segment and UID for the server started task.  
ADDUSER userid DFLTGRP(groupname) OMVS(UID(uid))  
Security Parameters  
Security is enabled by the security parameter described below.  
Note – If you want to use the GUI to run EXPORT, you must give the server address  
space sufficient authority to write to the data set name you are using for the manifest  
file. If you want to use the GUI to run IMPORT, you must give the server address space  
sufficient authority to read from the data set name you are using for the manifest file.  
authname title  
The authentication realm title, which appears on the browser userid/password  
prompt. The default is StorageTek Virtual Storage Manager.  
authuserfile file  
Specifies the text data set containing the user information data set. The file reference  
can be of the following formats:  
DSN:dsname - data set name  
DDN:ddname - DDNAME in startup proc  
20 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
The target data set can be a sequential data set or a PDS/PDSE member. The default  
is DDN:SKYPSWD which, in the sample startup proc SKYPROC, references the  
sample userlist in STKPARM.  
security {file | saf}  
Specifies the userid verification method:  
file  
Userid information is verified against the entries in the specified text file. The file  
entries take the format:  
userid userid_name password [access_level]  
access_level is read, update, control or alter. The default access level is read.  
See STKSAMP member USERLIST for a sample entry.  
Caution – If you change access levels for a user, the user has to log out and log back in  
again for the change to take effect.  
saf  
The specified system security package, which verifies userid and password  
information, and that valid users have access to the profile STKHTTPD in class  
FACILITY. The level of access in that profile is the user’s access level for server  
functions. The access level permits the GUI operations as shown in TABLE 2-8.  
TABLE 2-8  
VSM GUI Authorization Levels and Commands  
Commands  
All Queries  
All Reports  
Authorization Level  
Read  
Read  
Archive (for VTCS 6.2 and above)  
Control  
Update  
Update  
Update  
Update  
Control  
Control  
Control  
Control  
Control  
Control  
Control  
Control  
Control  
Control  
Alter  
Cancel  
Vary RTD  
Vary VTSS  
Vary Cluster Link  
Reconcile (for VTCS 6.2 and above)  
Migrate  
MVC Drain  
Recall  
Reclaim  
MVC Maintenance  
VTV Maintenance  
Consolidate  
Export  
Import  
Audit  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
TABLE 2-8  
VSM GUI Authorization Levels and Commands  
Commands  
Config  
Authorization Level  
Alter  
Decom  
Alter  
Set Migration Options  
Alter  
Content Parameters  
updated date  
The date and time (gmt) when the web content was last updated in an installation or  
PTF update. This parameter is required. For example: fri, 06 dec 2002 3:54:00 gmt  
translationfile file  
Specifies the data set containing the GUI data set name translations. The file  
reference can be of the following formats:  
DSN:dsname - for a data set  
DDN:ddname - for a DD in the startup proc  
The target data set can be a sequential data set or a PDS/PDSE member. The default  
is DDN:SKYTRSN which in the sample startup proc SKYPROC references the SMPE  
installed translation file. It may be specified more than once for multiple GUI  
applications.  
Miscellaneous Parameters  
allow xxx.xxx.xxx.xxx / mm  
Specifies the ip address range allowed to connect to the server. xxx.xxx.xxx.xxx is the  
base ip address in dotted decimal notation and mm are the significant bits. For  
example, 10.117.186.0 / 24specifies that connections are allowed from  
addresses 10.117.186.*  
authenicateexpiry period  
The period entries will remain in the authentication cache. Period can be specified in  
any combination of hours, minutes or seconds and if no unit is given seconds are  
assumed. The default period is one hour.  
bufferpool number  
Sets the minimum number of request buffers. Allowed range is 0 to 400. Default is  
200 buffers.  
22 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
cgionly yes|no  
Only allow CGI processing, default is no. Caution that this parameter MUST NOT be  
set to yes if using any GUI application as it will disable the GUI.  
closetimeout period  
Sets the request timeout (in seconds) on a client connection. The allowed range is 5  
to 60 seconds, default is 30 seconds.  
Cookieexpires time  
Specifies the period after which browser cookies expire.  
dirlists yes|no  
Enables generation of virtual directory listings, default is yes.  
deny xxx.xxx.xxx.xxx / mm  
Specifies the ip address range forbidden to connect to the server. Syntax as for  
allow.  
execcgi yes|no  
Specifies if CGI functions can run and should be left as yes. Defaults to yes.  
expiry period  
Specifies the default static content expiry period in seconds. Default is 21600 (six  
hours).  
home “url-string”  
Specifies the default home page for the server and is relative to the document root.  
For example:  
home /vsm/en/home/index.html”  
interface address  
For multihomed hosts, specifies the IP address of the network interface on which the  
server is to listen.  
Keepalive yes|no  
Enable persistent connections. Default is yes.  
keepalivetimeout period  
Sets the inactivity timeout (in seconds) on a persistent client connection. The allowed  
range is 15 to 300 seconds. Default is 300 seconds.  
linger period  
Sets the socket timeout (in seconds) on close before it is available for reuse. It can  
tuned to improve socket availability at high transaction rates but setting too low can  
cause connections to be disconnected before all data is delivered to the client. The  
default is the installation TCP/IP default.  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
loadmodule module  
Preloads the specified CGI module. The default is to dynamically load and unload  
such modules as required.  
maxclients number  
Specifies the maximum number of worker tasks that can run.  
maxrequestsperchild number  
Sets the maximum number of requests to be serviced by a worker task before it is  
restarted. The default is no limit.  
maxpasswordlength number  
Sets the maximum allowed length of a password. Defaults to 8 characters.  
maxuseridlength number  
Sets the maximum allowed length of a password. Defaults to 8 characters.  
messageprefix prefix  
Specifies the three-character prefix for server messages. Default is “SKY”.  
order check-order  
Specifies the order in which a connection source ip address is checked against any  
allow and/or deny parameters.  
Allowable sequences:  
allow-deny - Allow directives are checked before deny directives. Unmatched  
requests are denied.  
deny-allow - Deny directives are checked before allow directives. Unmatched  
requests are allowed.  
mutual-exclusion - Only requests that are allowed by an allow directive and are not  
forbidden by a deny directive are allowed.  
For example: order allow-deny  
The default order is deny-allow. Note that disallowed connections are silently  
dropped for security reasons and no error messages are returned to such  
connections.  
receivebuffersize value  
Changes the TCP receive buffer size if authorized. Valid range is 4096 to 65536.  
Default is the TCP/IP stack default.  
sockimplementation type  
Specifies the socket implementation to be used by the server.  
Socktimeout period  
Specifies the socket timeout in seconds.  
24 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Startservers number  
Specifies the default number of running worker tasks.  
Serveradmin admin  
Identifies the server administrator e-mail address on directory listings.  
secure level  
Specifies the directory levels under which security verification is required. It can be  
specified for each application but for efficiency it is recommended to have as few as  
possible. Default is /.  
sendbuffersize value  
Changes the TCP send buffer size if authorized. Valid range is 4096 to 65536. Default  
is the TCP/IP stack default.  
setenv name text  
Sets an environment variable accessible to cgi modules.  
serversignature yes | no  
Specifies whether the server identification line should be included at the bottom of  
server generated pages such as directory listings or error pages. Default yes.  
tcpipprefix high_level_qualifier  
Sets the system TCPIP high level qualifier. Default is TCPIP. Suggest also allocating  
the <tcpipprefix>.TCPIP.DATA data set in the started task JCL with DD SYSTCPD.  
tcpipdata reference  
Sets the reference to the TCPIP data set in the form DSN:data set or DDN:ddname.  
Defaults to DDN:SYSTCPD  
Start the VSM GUI Server  
To start the VSM GUI server, enter the following operator command.  
START SKUPROC  
The server is up and running when the following message appears:  
SKY003I HTTPD ready to accept requests  
312651601 • Rev A  
Chapter 2 Installing and Configuring the VSM GUI 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connect to the VSM GUI Server  
Specify the URL of the server in the browser window. For example, to connect to the  
web server running on the MVS system lstcrmvs in the production domain on port  
8888 the URL is:  
To connect to this server using default port 80:  
Control the VSM GUI Server  
By default, when the VSM GUI server is started, it uses the SKYPRM00 member in  
STKPARM. You can stop the server by entering one of the following MVS commands:  
P SKUPROC  
F SKUPROC,SHUTDOWN  
To display the status of the server, enter the following MVS command:  
F SKUPROC,D S  
The following shows a display status response:  
SKY016I HTTPD Server 6.2.0 started at Fri Jan 24 06:51:35 2003  
requests received 85  
tasks default: 20 active: 20 limit:40  
SKY053I Current active worker tasks: 0  
This response shows an idle system with the default number of worker tasks, which  
handle client connections, idle waiting for work. At times of peak demand, the server  
can dynamically start additional tasks up to the limit.  
To display the server connections, enter the following MVS command:  
F SKUPROC,D C  
The following shows a display connections response:  
SKY031I Connections total: 114 max: 63/min  
SKY032I Connection rates: 0/min 0/hour  
SKY026I Task: 5 Requests: 1 Client: 199.117.186.54 : 36292  
This response shows one client active whose IP address is 199.117.186.54 and using port  
36292.  
26 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3
CHAPTER  
Installing PTFs for VSM GUI  
This chapter describes how to install the corrective service PTFs for VSM GUI, which  
you can download from the Sun StorageTek Customer Resource Center at:  
Note – Before you install PTFs, you must install VSM GUI as described in “Installing  
For information on accessing the CRC, see “Customer Resource Center” on page xii.  
Installing the PTFs  
After you have downloaded the desired PTFs from the StorageTek CRC, install them  
using the following procedure:  
1. Ensure that you have customized the installation jobs as described in “Set Up the  
2. If necessary, modify member V1RCV.  
Change the SMPPTFINand SMPHOLD DDs to point to the downloaded data set names. If  
there was no HOLDDATA downloaded, then remove the SMPHOLD DD and only receive  
SYSMODS.  
3. Run member V1RCV to RECEIVE the VSM GUI PTFs.  
4. If necessary, modify member V2APPLY.  
Before running the apply job, review the output from the receive job for HOLDDATA, and  
follow the instructions given for each held PTF. When the requirements are met, bypass  
the hold condition for that held PTF in the apply job with the BYPASSparameter. Do not  
bypass HOLDERROR conditions.  
5. Run member V2APPLY to APPLY the VSM GUI PTFs.  
312651601 • Rev A  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Note – Expect a return code of 04 with SMP/E message GIM23903W for link-edit  
processing of VSM GUI modules into the SKYRTNS and SKURTNS libraries. The Binder  
message IEW2454W is generated for each routine linked into these libraries. The link-  
edit processing of modules into the STKLOADlibrary should complete with a return code  
0.  
6. Run member V3ACCEPT to ACCEPT the VSM GUI FMIDs.  
Use the same BYPASS parameters that were used in the APPLY job. Use the ACCEPT  
CHECK option, as often as necessary, to identify SMP/E processing problems before the  
actual ACCEPT process.  
Note – Expect a return code of 04 with SMP/E message GIM24701W. This message is  
normal when SMP/E accepts new elements into the distribution libraries for the first  
time.  
After the ACCEPT succeeds, you have installed the VSM GUI PTFs.  
28 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
CHAPTER  
Installing Service Tapes for VSM GUI  
This chapter describes tells how to install service tapes for VSM GUI.  
Note that you can also receive service via PTFs downloaded from the Storage CRC as  
Before you install a service tape, VSM GUI must be installed as described in “Installing  
and Configuring the VSM GUI” on page 3. Contact StorageTek Software Support for a  
current service tape containing those PTFs that have become available since the base  
tape was created. For more information, see “Customer Support” on page xiii and  
The VSM GUI service tape contains both the current PUT level PTFs and a file  
containing all cumulative PTFs available for the product up to that PUT level. Each PTF  
on the file is assigned a source identifier of PUTyynn, where yy is the year and nn is the  
sequence number. This value will be the same as the PUT level (for example, PUT9901).  
This allows previous PUTs to be identified and allows installation by source identifier  
if desired. Additional source identifiers may be included on the SMP/E RECEIVE job.  
See “Service Tape Contents” on page 30 for information about the files on the service  
tape.  
312651601 • Rev A  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Service Tape Contents  
Table 4-1 lists the file names contained in a service tape.  
TABLE 4-1  
File Number  
1
File Names for VSM GUI Service Tapes  
Data Set Name  
Description  
SMPPTFIN  
Corrective Service PTFs.  
For a PUT, these are the PTFs for the current PUT level.  
2
3
4
5
6
7
PTFLIST  
SMPEJCL  
SMPHOLD  
JCLIN  
List of Corrective Service PTFs contained on file 1  
Service Tape Installation JCL (Optional)  
SMP/E external hold statements  
SMP/E JCLIN  
UCLIN  
SMP/E UCLIN  
PUTCUM  
Cumulative Service PTFs.  
For a PUT, these are all of the PTFs for all the PUTs that have been  
released. This includes those PTFs in file 1.  
Unload the SMP/E JCL Data Set from the  
Service Tape  
The service tape SMP/E JCL Data Set contains sample JCL members for the installation  
process; see “Service Tape Contents” on page 30 for more information. Use the JCL in  
FIGURE 4-1 to create a copy of the SMP/E JCL from file 3 of the distribution tape to help  
install the service tape contents. Obtain the actual volume serial “VTyynn” of the tape  
from the tape cartridge external label and make other modifications as necessary.  
30 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
//jobcard JOB ‘accounting information’  
//*  
//  
EXEC PGM=IEBCOPY  
//SYSPRINT DD SYSOUT=*  
//SYSIN  
//*  
DD DUMMY  
//SYSUT1 DD DSN=SMPEJCL,DISP=(OLD,KEEP),  
//  
UNIT=3480,  
//  
LABEL=(3,SL,EXPDT=98000),VOL=SER=VTyynn  
//*  
//SYSUT2 DD DSN=hlq.SMPE.JCL,DISP=(,CATLG),  
//  
UNIT=SYSALLDA,SPACE=(TRK,(10,2,10)),  
//  
DCB=(RECFM=FB,LRECL=80,BLKSIZE=23440)  
//*  
FIGURE 4-1 JCL to Unload the VSM GUI Service Tape SMP/E JCL  
Installing a Service Tape  
Install the contents of a service tape using the following procedure.  
1. Ensure that you have customized the installation jobs as described in “Set Up the  
2. If necessary, modify member U1RCU.  
If the cumulative service was downloaded from the StorageTek CRC, change the  
SMPPTFIN and SMPHOLD DDs to point to the downloaded data set names. If it is a  
physical tape, obtain the actual volume serial number “VTyynn” from the tape cartridge  
external label. If there was no HOLDDATAdownloaded, then remove the SMPHOLDDD and  
only receive SYSMODS.  
3. Run member U1RCV to RECEIVE the VSM GUI service.  
4. If necessary, modify member U2APPLY.  
Before running the apply job, review the output from the receive job for HOLDDATA, and  
follow the instructions given for each held PTF. When the requirements are met, bypass  
the hold condition for that held PTF in the apply job with the BYPASSparameter. Do not  
bypass HOLDERROR conditions.  
5. Run member U2APPLY to APPLY the VSM GUI service.  
312651601 • Rev A  
Chapter 4 Installing Service Tapes for VSM GUI 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Note – Expect a return code of 04 with SMP/E message GIM23903W for link-edit  
processing of VSM GUI modules into the SKYRTNS and SKURTNS libraries. The Binder  
message IEW2454W is generated for each routine linked into these libraries. The link-  
edit processing of modules into the STKLOADlibrary should complete with a return code  
0.  
6. Run member U3ACCEPT to ACCEPT the SYSMODs.  
Use the same BYPASS parameters that were used in the APPLY job. Use the ACCEPT  
CHECK option, as often as necessary, to identify SMP/E processing problems before the  
actual ACCEPT process.  
Note – Expect a return code of 04 with SMP/E message GIM24701W. This message is  
normal when SMP/E accepts new elements into the distribution libraries for the first  
time.  
After the ACCEPT succeeds, you have installed the VSM GUI service tape contents.  
32 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
APPENDIX  
VSM GUI Messages and Codes  
VSM GUI Messages  
SKY001I  
name Server version starting on system running MVS level  
httpd server startup message  
SKY002E  
Error binding server socket ss, errno=nnn: mmm - terminating  
The server cannot bind to the specified network port ss due to the error indicated by  
the errno code nnn and error message mmm. The server shuts down.  
SKY003I  
name ready to accept requests  
The server name is ready for normal operation.  
SKY004E  
Error opening server socket errno=nnn: mmm - terminating  
The server cannot open a socket connection to its configured port due to the error  
indicated by the errno code nnn and error message mmm. The server shuts down.  
SKY005E  
Server select failed rc=ret err=msg  
An error occurred whilst listening for a client connection  
312651601 • Rev A  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
SKY006I  
TCP/IP connection terminated  
The client connection was terminated.  
SKY007E  
Accept error - shutting down  
There was an error in network connection accept processing. The server shuts down.  
SKY008E  
Error reading request  
There was a network error whilst reading a client request.  
SKY013I  
Shutdown command from operator acknowledged  
The server has received a console command to shutdown.  
SKY016I  
name Server ver started at tttt  
“requests received: nnn  
“tasks default: dd active: aa limit: ll  
Response to an operator display status command and indicates the server name,  
version, start date and the total number of requests received. It also details the worker  
task settings, the default number of idle tasks, the maximum limit of dynamically  
started tasks and the current number of active tasks.  
SKY018I  
Request n task completed rc=ret  
The worker task t has completed with return code ret.  
SKY023E  
Unknown server command: cmd  
The command cmd is not a valid console command.  
SKY025E  
Invalid command option: oooo  
The option oooo is not a valid option for the operator command.  
34 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY026I  
Task: t Requests: n Client: xxx.xxx.xxx.xxx : pppp  
Response to a console display client console command. Task t has serviced n requests  
from the client at IP address xxx.xxx.xxx.xxx port pppp.  
SKY027I  
No active client connections  
The response to a display client command when there are no client connections.  
SKY030E  
Missing to/from translation string  
The data set file name translation is incorrect.  
SKY031I  
Connections total: nn max: mm/min  
Response to a console display client command, there have been a total of nn  
connections at a maximum rate of mm per minute.  
SKY032I  
Connections rates: nn/min mm/hour  
Response to a console display client command, the connection rates are nn per minute  
and mm per hour.  
SKY031W  
Not APF authorized, some facilities not available  
The httpd server has found it is not APF authorized.  
SKY040I  
Option nnnn ssss  
The parameter option nnnn set to ssss  
SKY043E  
Terminating execution due to parameter error(s)  
There was an error is one or more parameters. The server shuts down.  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY045E  
SAF authentication requested but not APF authorized  
SAF authentication requires caller to be APF authorized but server is not APF  
authorized. The server will shut down.  
SKY046E  
Supplied parm is too long  
The length of the parameter string parm exceeds the allowed length.  
SKY047E  
Unable to open dsname  
The httpd server was unable to open the data set dsname in response to a client  
request.  
SKY048E  
abend_message_line  
Message number for abend reporting messages.  
SKY049E  
Not APF authorized, cannot continue  
The server is not APF authorized but APF authorization is required. The server will  
shut down.  
SKY050E  
Task shutdown time expired, terminating tasks  
During httpd server shutdown, some tasks have not stopped before the shutdown  
timeout was exceeded. These task will be forcibly terminated.  
SKY051E  
Cannot find server module name  
When the httpd server did its startup checks, it could not find its module: name.  
SKY052E  
Cannot find all server modules, shutting down  
The httpd server could not find all of its modules when it did its startup checks, the  
server shuts down.  
36 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY053I  
Current active worker tasks: t  
The current number of worker tasks for servicing requests.  
SKY053E  
Fatal error in main task, commencing forced shutdown  
The server has suffered a fatal error in tis main task and was not able to do an orderly  
shutdown.  
SKY054E  
Fatal error in main task, attempting orderly shutdown  
The server has suffered a fatal error in its main task and is attempting to do an orderly  
shutdown  
SKY055I  
Forcibly terminating task t  
The task t will be forcibly terminated.  
SKY056I  
Disable abend handling option specified, handling disabled  
The httpd server abend handlers will not be enabled so any abends can cause dumps  
and may also crash the server.  
SKY059E  
Error initializing translation tables  
There was an error initializing the server file name translation table.  
SKY060E  
SERVERBASE not set, shutting down  
The required parameter SERVERBASE was not set in the parameter file. The server  
shuts down since it cannot locate its data files.  
SKY061I  
Authentication request received from client at xxx.xxx.xxx.xxx : pppp  
A request to authenticate was received from the client at network address  
xxx.xxx.xxx.xxx and port pppp.  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY062E  
Invalid update date: ssss  
The string ssss is in not a valid date format.  
SKY064W  
Dynamicallocationfordataset:ddderrorrc=nnreason=rrrinfo=iii  
Details the dynamic allocation error codes for a file allocation failure of dataset ddd.  
SKY065W  
Unable to open dataset ddd: rrr  
Shows the reason code rrr why the data set ddd could not be opened.  
SKY067I  
Buffer pool limit: nn current: mm  
Shows request buffer pool utilization, pool limit and current values.  
SKY068E  
CGI api call error for <function>: <reason>  
There was an error calling the CGI function <function> for reason <reason>.  
SKY069E  
task <nnn> clientConnect: taksocket error: <err> <reason>  
The worker task <nnn> encountered an error obtaining the connection socket with  
error code <err> and error message <reason>.  
SKY070E  
Passrequest: givesocket error: <err> <reason>  
The main task encountered an error passing a connection socket to a worker task, error  
code <err> and error message <reason>.  
SKY071W  
Cannot utilize socket implementation <type> errno <err> <msg>  
The server cannot use the specified socket implementation <type> because of error  
code <err> and message <msg>. Server processing continues with the default socket  
implementation.  
38 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY072I  
Loaded module <module>  
M o d u l e < m o d u l e > w a s l o a d e d a s r e q u e s t e d b y a L O A D M O D U L E p a r a m e t e r .  
SKY073E  
Connection socket <nn> out of range  
The connection socket exceeds the supported range of sockets. The connection will be  
dropped and server operation continues.  
SKY074W  
Unable to allocate <dsn> Reason: <rr> rc=<nn> code=<cc>  
The dataset <dsn> could not be allocated due to reason <rr>, dynamic allocation return  
code <nn> and code <rr>.  
SKY075I  
Socket <nnn> settings: linger=<spec> sndBuf=<sss> rcvBuf=<rrr>  
Server connection listener socket <nnn> has the following attributes: - linger=<spec>  
is the socket time-out on close, either default or (1,<time-in-seconds>) the socket is  
unavailable for reuse.  
SKY076E  
Cannot allocate <dsn>, dynamic allocation error rc=<rc> error=<err>  
info=<inf>  
A dataset cannot be dynamically allocated, dairfail return and information codes.  
SKY100W  
Unable to set socket option to value  
The named socket option could not be set. Processing continues.  
SKY101W  
Unable to set socket option  
A socket option could not be set.  
SKY102E  
Socket option error: explanation  
Indicates why a socket option could not be set.  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY103E  
Cannot open parameter file dsname, terminating  
The httpd server was unable to open the parameter file dsname. The server shuts  
down.  
SKY104E  
Parameter ppp invalid  
The parameter ppp is not known.  
SKY105E  
Unexpected character c encountered, skipping line  
When parsing the parameter file an unexpected character was encountered. The  
parameter is skipped by moving onto the next line.  
SKY106E  
Expected number but non numeric: ssss  
When parsing the parameter file a non numeric item was found when a number was  
expected.  
SKY107I  
parm set to vvvv  
The parameter parm is set to value vvvv  
SKY108E  
Expected string: sss , skipping  
When parsing the parameter file the string ssss was expected but not found. Parsing  
skips on the next parameter.  
SKY109I  
pppp set to vvv  
When reading the parameter file the parameter pppp was set to the value vvv  
SKY110E  
Unknown token type: tttt  
The parameter token is unknown.  
40 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY112E  
Cannot create tbl, terminating  
During initialization the memory table tbl cannot be allocated and the server stops.  
SKY113E  
Cannot start task tttt, terminating  
During initialization, the task tttt could not be started and the server stops.  
SKY114I  
Task tttt completed, rc = nn  
The task tttt completed with return code nn.  
SKY115I  
Commencing server shutdown  
The server has started shutting down.  
SKY116E  
Task tttt unable to get client id  
An error occurred when passing a socket connection to the work task tttt.  
SKY117E  
Spurious wakeup, work to do ECB not posted.  
This is an internal error and should not occur.  
SKY118I  
Task t waiting for work  
The worker task t is now idle after finishing a request.  
SKY119I  
Task t shutting down  
Task t has commenced shutting down.  
SKY120E  
Task t unable to allocate dir list buffer  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The worker task t was unable to allocate a memory buffer needed for a directory listing  
SKY121E  
Task t unable to open directory readme  
The worker task t encountered an error when attempting to open a directory readme  
file whilst listing a directory.  
SKY122E  
Task ttconnection error with xxx.xxx.xxx.xxx errno error_text  
The worker task t had a connection error (error number errno, text error_text) with the  
client at ip address xxx.xxx.xxx.xxx  
SKY123E  
Task t, connection eof from xxx.xxx.xxx.xxx  
For worker task t, the connection to client at IP address xxx.xxx.xxx.xxx ended  
SKY124I  
Task t connection terminated by peer adr  
The network connection to worker task t was terminated by the client with ip address  
adr  
SKY125E  
Task t cmp, abend aaa caught  
The abend handler for task t in component cmp, intercepted a type aaa abend. Task t  
will be shutdown and a replacement task created.  
SKY126E  
Task t cmp, illegal instruction abend caught. Code aaa  
The abend handler for task t in component cmp, intercepted an illegal instruction abend  
of type aaa. Task t will be shutdown and a replacement task created.  
SKY127E  
Task t cmp memory access abend caught. Code aaa  
The abend handler for task t in component cmp, intercepted an memory abend of type  
aaa. Task t will be shutdown and a replacement task created.  
42 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY128E  
Task t request error nnn msg: description  
For worker task t, there was an http protocol error for the client request. Code nnn,  
message msg and description dddd  
SKY129E  
ppp out of valid range min ñ max  
The numeric parameter ppp is outside the allowed range.  
SKY130I  
hhh handler ready  
The handler hhh task has finished initializing and is ready for work.  
SKY131I  
hhh handler shutting down  
The handler hhh task has started shutting down.  
SKY132E  
hhh handler startup timeout, terminating  
The startup timeout for the handler task hhh has been exceeded. The handler will be  
terminated.  
SKY133E  
Unable to start hhh handler, terminating  
The httpd server was unable to start it handler task hhh. The server shuts down.  
SKY134E  
Unable to allocate mmm memory, terminating  
During initialization, memory could not be allocated for mmm memory. The server  
stops.  
SKY135E  
Unable to open log, reason: rrr  
The log handler task was unable to open the log file for reason rrr.  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SKY136W  
Out of memory for stack space, requested nnnn bytes  
A httpd server task was unable to allocate stack memory.  
SKY138W  
No free worker tasks, at maximum limit  
A request has been received but there are no idle worker tasks and the number of tasks  
is at the maximum limit. A server busy request is returned to the client. If this condition  
occurs frequently consider increasing the maximum limit of worker tasks to a value  
where this is a rare occurrence.  
SKY139E  
Request token nnn Text=ttttt  
Debugging message issued for each token in an invalid request.  
SKY140E  
Request has nnnn tokens  
Debugging message issued when an invalid request is received.  
44 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VTCS PGMI Return Codes  
TABLE A-1 VTCS PGMI Return Codes  
Return Code  
Reason Code  
Description  
16  
16  
32  
32  
32  
32  
32  
32  
32  
32  
32  
36  
48  
0
Non-zero POST code from SWSPGMIS - probable abend  
Attach for SWSPGMIS task failed  
PGMI interface area not present or not valid  
Request area not present or length not between 0 and 32000.  
Required user exits not available  
Unknown command  
4
8
12  
16  
24  
28  
32  
40  
No matching categories  
Not authorized  
HSC at the wrong level  
Advanced Management Feature required and not enabled  
Error detected in the XML structure  
312651601 • Rev A  
Appendix A: VSM GUI Messages and Codes 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
46 VSM GUI Getting Started Guide • July 2007  
Rev A • 312651601  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
N
P
C
S
Set Up the SMP/E Environment and Install the  
Software, 13  
D
F
H
U
Unload the SMP/E JCL Data Set from the Service  
Tape, 30  
I
installation  
Unloading VSM GUI SMP/E JCL Data Set from CD-  
ROM, 12  
Unloading VSM GUI SMP/E JCL Data Set from  
Tape, 12  
V
VSM  
installation  
M
312651601 • Rev A  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com  
ARGENTINA: 5411-4317-5636 • AUSTRALIA: 1-800-550-786 • AUSTRIA: 43-1-601-26-0 • BALKANS: 301-6188-111 • BELGIUM: 32 2-704 89 83 • BRAZIL: 55-11-51872100 • BRUNEI: 65-216-8333 • CANADA: 1-800-422-8020 (GENERAL); 416-964-2001 (LEARNING MANAGEMENT SYSTEM SALES,TORONTO) • CHILE: 562-372-4500 • COLOMBIA: 571-629-2323  
CZECH REPUBLIC: 420 2 33009311 • DENMARK: 45 4556 5040 • EGYPT: 00 202 570 9442 • FINLAND: 358-9-525-561 • FRANCE: 33-1-41-33-17-17 • GERMANY: 49-89-460-08-2788 • GREECE: 30-01-6188101 • HONG KONG: 852-2877-7077 • HUNGARY: 361-202-4415 • INDIA: 91-80-229-8989 • INDONESIA: 65-216-8333 • IRELAND: 353-1-668-4377  
ISRAEL: 972-9-9710500 • ITALY: 39-02-9259511 • JAPAN: 81-3-5779-1820 • KOREA: 82-2-3453-6602 • MALAYSIA: 603-2116-1887 • MIDDLE EAST: 00 9714 3366333 • MEXICO: 525-261-0344 • NETHERLANDS: 31-33-4515200 • NEW ZEALAND: 0800-786-338 • NORTH WEST AFRICA: 00 9714 3366333 • NORWAY: FROM NORWAY: 47-22023950, TO NORWAY:  
47-23369650 • PAKISTAN: 00-9714-3366333 • PEOPLE'S REPUBLIC OF CHINA: 8610-6803-5588 • PHILIPPINES: 632-885-7867 • POLAND: 48-22-8747848 • PORTUGAL: 351-21-413-4000 • RUSSIA: 7-095-935-8411 • SAUDI ARABIA: 00 9714 3366333 • SINGAPORE: 65-216-8300 • SOUTH AFRICA: 27-11-256-6300 • SPAIN: 34-902-210-412 • SRI LANKA:  
65-2168333 • SWEDEN: 46-8-631 22 00 • SWITZERLAND: 41-1-908-90-50 (GERMAN) 41-22-999-0444 (FRENCH) • TAIWAN: 886-2-25185735 • THAILAND: 662-344-6855 • TURKEY: 90 212 335 22 00 • UNITED KINGDOM: 44-1276-416-520 • UNITED STATES: 1-800-422-8020 • VENEZUELA: 582-905-3800 • VIETNAM: 65-216-8333 • WORLDWIDE  
HEADQUARTERS: 1-650-960-1300  
THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo are trademarks or registered trademarks of Sun Microsystems, Inc. in the  
United States and other countries.  
SUN™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Silicon Power Computer comm Computer Accessories FLSG620DA User Manual
Silvercrest Hair Dryer SHTR 2200 A1 User Manual
Snapper Utility Vehicle 7 4510 User Manual
Sony Camera Accessories CCU TX7P User Manual
Sony DVD Recorder MZ NH700 User Manual
Sony Speaker SAW2500 User Manual
SOYO Car Video System M17GS User Manual
Speco Technologies Security Camera HT5100BPVFG User Manual
Symbol Technologies Barcode Reader PDT 1100 User Manual
Tanita Fitness Electronics PD642 User Manual