SUMMIT
PLATINUM D4 , D6
BUILT-IN LP GAS GRILL INSTALLATION GUIDE
THIS GAS APPLIANCE IS DESIGNED
FOR OUTDOOR USE ONLY.
42369
LOCATING YOUR GRILL
When determining a suitable location for your Summit® gas grill installation, give attention to concerns such as exposure to wind, proximity to traffic paths, and
keeping any gas supply lines as short as possible. Never locate the Summit® gas grill in a garage, breezeway, shed, under an unprotected overhang, or other
enclosed area. Locate the grill and structure so there is enough room to safely evacuate the area in case of a fire.
CLEARANCE FROM SURFACES OR STRUCTURES
24 inches (61 cm) Any Surface
ƽWARNING: Clearance from any surface or structure is
24 inches (609.6 mm) from the back and sides of the grill.
Refer to “Typical Gas Supply Installation” before starting
installation.
27 inches (685.8 mm) min. for
ƽWARNING: The structure, “island”, countertops, and
adjacent work areas for the built-in grill installation must be
lid clearance
built from noncombustible materials only.
Grill Frame
NOTE: If you have questions on what materials are considered noncombustible,
contact your local building materials supplier or fire department.
Note: For a countertop treatment: Recommended 3/4 inch
(19.1 cm) overhang. Notch front edge for frame to fully
slide in.
ƽ WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
ALL DIMENSIONS ARE TO FINISHED SURFACES.
Built-In Cutout Dimensions
3
D4
D6
Tolerances
1
1
2
3
30 1
34 1
/
˝
˝
38 1
34 1
/
˝
˝
+
+
+
/
/
/
4” - 1
4” - 1
4” - 1
/
/
/
˝
4
˝
4
˝
4
4
4
2
1
1
/
/
4
4
21˝
21˝
1
42369 US 11/22/05
LP
Download from Www.Somanuals.com. All Manuals Search And Download.
3
PARTS LIST
D4
Left Door - 1
Lid - 1
Cookbox - 1
Right Door - 1
Warming Rack - 1
OR
™
Warm-Up Rack - 1
D6
Lid - 1
Right Enclosure Panel - 1
Cookbox - 1
Front Frame Rail - 1
Rear Frame Rail - 1
Left Enclosure Panel - 1
Front Vent Panel - 1
Rear Panel
Assembly - 1
Rear Vent - 1
Bottom Shelf - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
4
PARTS LIST
®
Flavorizer Bars - 2 Sets
Wrench - 1
x10 Sheet Metal Screws - 3
Stainless Steel
Cooking Grates
Plastic Anchors - 3
1/2 inch Bolts
(1/4 x 20 x 1/2 inch Bolt) - 8
- 2
- 3
4B
6B
#10-32 x 1/4 inch Steel Screws - 5
Nylon Washer - 8
Bottom Tray - 1
Catch-Pan Holder - 1
Handle - 2
Handle Hardware - 4
Rotisserie - 1
Catch-Pan - 1
Disposable Drip Pans - 2
Rotisserie Motor - 1
Rotisserie Bracket - 1
Hinge Pin- 2
Hair Pin Cotter- 2
Corrugated gas line - 1
Keps Nuts (1/4 x 20 Blk Zinc) - 2
Rotisserie Bracket Hardware- 2
Right Front Vent Clip - 1
Left Front Vent Clip - 1
Smoker - 1
7/16 inch Wrench - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
5
EXPLODED VIEW - PLATINUM D4
®
7740501 - Summit Platinum D4 LP Built-In 092005
1
2
3
38
39
4
40
5
6
7
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
57
58
59
60
26
27
61
62
63
64
65
66
67
28
29
30
68
31
32
69
70
33
34
35
71
72
73
74
36
37
75
76
Download from Www.Somanuals.com. All Manuals Search And Download.
6
EXPLODED VIEW - PLATINUM D6
®
7790501 - Summit Platinum D6 LP Built-In 092005
1
2
3
42
43
4
5
6
7
44
45
46
47
48
49
50
51
52
8
9
10
11
12
13
53
54
55
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
56
57
58
59
60
61
62
63
30
64
65
66
67
68
31
69
70
32
33
71
34
35
36
72
73
74
37
38
75
76
39
40
41
77
78
Download from Www.Somanuals.com. All Manuals Search And Download.
7
EXPLODED VIEW LIST - PLATINUM D4
1.
2.
3.
4.
5.
6.
7.
8.
Hinge Pin
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
Control Panel
Front Panel
Vent Cover Assembly
Front Frame Rail
Left Rear Panel
Left Panel
Handle Assembly
Bottom Shelf
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
Rotisserie Fork Screw
Rotisserie Fork
Rotisserie Shaft
Cookbox Assembly
Electrode Assembly (16 1/4 inch wire)
Right Burner Tube
Heat Shield
Battery Shield Assembly
Main Gas Line
Thermometer Hardware
Thermometer Bezel
™
Warm-Up Basket
Smoker Assembly
Flavorizer Bar Assembly w/ Smoker
Smoker Box Chip Grate
Rotisserie Motor
Motor Bracket
Motor Bracket Screw
1/4 - 20 inch Keps Nut
Smoker Electrode Assembly
(10 1/2 inch wire)
Electrode Assembly (8 3/4 inch wire)
Crossover Tube
Smoker Burner Tube
Left Burner Tube
10 - 24 x 1/2 inch Black Screw
Manifold
Negative Ignition Switch Wire
Positive Ignition Switch Wire
Four Output Ignition Module Assembly
Ignition Switch Button Assembly
10 - 24 x 1/2 inch Black Screw
Small Control Knob
®
9.
Toe Kick Vent
10.
11.
12.
Left Vent Bracket
Left Door Assembly
Right Door Assembly
Hair Pin Cotter
Bottom Tray
Summit Catch Pan Holder
Summit Catch Pan
Summit Drip Pan
Rear Frame Rail
Rear Vent Hardware
Rear Panel Hardware
Right Rear Panel
Right Panel
10 -16 x 3/4 Screw w/ Washer
Plastic Plug
Door Stop
Door Bushing
Door Plug
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
Lid Assembly
®
1/4 - 20 x 1 1/4 inch Bolt
IR Rain Cover Hardware
12 inch Cook Grate
IR Rain Cover
10 - 24 x 1/2 inch Stainless Steel Screw
Right Flavorizer® Bar Assembly
IR Burner
IR Cover Box
Warming Rack
Thermocouple
IR Gas Line
1/4 - 20 x 1/2 inch Black Bolt
Right Vent Bracket
Control Knob
IR Electrode Wire
EXPLODED VIEW LIST - PLATINUM D6
1.
2.
3.
4.
5.
6.
7.
8.
Hinge Pin
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
Small Control Knob
Control Knob
Control Panel
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
Thermocouple
IR Gas Line
Rotisserie Shaft
IR Electrode Wire
Cookbox Assembly
Electrode Assembly (16 1/4 inch wire)
Electrode Assembly (25 1/2 inch wire)
Heat Shield
Main Gas Line
Battery Shield Assembly
Bottom Tray
Summit Catch Pan Holder
Summit Catch Pan
Summit Drip Pan
Thermometer Hardware
Thermometer Bezel
™
Warm-Up Basket
Front Panel
8 inch Cooking Grate
Smoker Assembly
Smoker Box Chip Grate
Flavorizer Bar Assembly w/ Smoker
Rotisserie Fork
Rotisserie Motor
Motor Bracket
Motor Bracket Screw
1/4 - 20 inch Keps Nut
Smoker Electrode Assembly
(10 1/2 inch wire)
Electrode Assembly (8 3/4 inch wire)
Crossover Tube
Smoker Burner Tube
Left Burner Tube
Right Burner Tube
10 - 24 x 1/2 inch Black Screw
Manifold
Negative Ignition Switch Wire
Positive Ignition Switch Wire
Six Output Ignition Module Assembly
Ignition Switch Button Assembly
10 - 24 x 1/2 inch Black Screw
Vent Cover Assembly
Front Frame Rail
Left Rear Panel
Left Panel
Door Stop
Handle Assembly
Bottom Shelf
Left Vent Bracket
Toe Kick Vent
Left Door Assembly
Right Door Assembly
Hair Pin Cotter
®
9.
10.
11.
12.
13.
14.
Rear Frame Rail
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
Rear Vent Hardware
Rear Panel Hardware
Right Rear Panel
Right Panel
10 -16 x 3/4 Screw w/ Washer
Plastic Plug
Door Bushing
Door Plug
1/4 - 20 x 1/2 inch Black Bolt
Right Vent Bracket
®
Lid Assembly
1/4 - 20 x 1 1/4 inch Bolt
12 inch Cook Grate
IR Rain Cover Hardware
®
Right Flavorizer Bar Assembly
IR Rain Cover
10 - 24 x 1/2 inch Stainless Steel Screw
Warming Rack
Rotisserie Fork Screw
IR Burner
IR Cover Box
Download from Www.Somanuals.com. All Manuals Search And Download.
8
ASSEMBLY
2
1
1
2
1
Arrow stickers on
Frame Rail (1) and
Left Side Panel (2)
should point toward
each other (shown
above). Door Stop
Bracket (3) should
be positioned as
shown (left).
3
2
ƽ ATTENTION!
Do not fully tighten screws.
Clips should slide freely when
installed.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
ASSEMBLY
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
10
ASSEMBLY
5
Download from Www.Somanuals.com. All Manuals Search And Download.
11
ASSEMBLY
®
ƽ CAUTION: Use two people to lift and install the Summit Built-In frame assembly.
a.) Lift the frame assembly into the “island” structure opening. Make sure the frame is resting level on the finished surface of the
structure.
b.) Adjust the Front Vent to rest squarely on ground.
c.) Apply a bead of silicone sealant (1) around the perimeter and front edges of the grill that are in contact with the “island”
structure. This will prevent moisture seepage. The sealant you use must have a temperature rating above 120°F (48.8° C).
6
Any Surface
24 inches (610mm)
Note: For a countertop treatment
Recommended 3/4 inch (19.1 mm)
overhang. Notch front edge for
frame to fully slide in.
a.
Frame
c.
Any Surface
(1)
24 inches (610mm)
Frame
b.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
ASSEMBLY
7
D4
D6
(3)
(1)
(2)
Download from Www.Somanuals.com. All Manuals Search And Download.
13
ASSEMBLY
8
D6
D4
(1)
(2)
Download from Www.Somanuals.com. All Manuals Search And Download.
14
ASSEMBLY
D6
D4
9
a
b
c
Match Holder
Download from Www.Somanuals.com. All Manuals Search And Download.
15
ASSEMBLY
10
1/4" Drill Bit
11
Download from Www.Somanuals.com. All Manuals Search And Download.
16
ASSEMBLY
12
13
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
17
GAS SUPPLY
BUILT-IN GAS LINE LOCATIONS
TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION
Note: Leave an access in the “island” structure for gas supply and regulator
We recommend that this installation be done by a LICENSED professional.
General Specifications for Piping
®
service that is not inside the grill structure. Weber has a gas line and
regulator access door (part # 36311) available from your dealer or call
Customer Service at 1-800-446-1071.
Note - Contact your local municipality for building codes regulating outdoor
gas grill installations. In absence of Local Codes, you must conform to the
Note: Area should be kept clear of sharp, jagged, or extremely abrasive
surfaces to avoid possible damage to gas supply lines. Exercise caution when
pulling gas lines through built-in structure.
latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.
•
This grill is designed to operate at 10.5 inches of water column pressure.
An LP in line regulator may be necessary for this pressure.
ƽ Caution: If young children are in the area, a
locking valve should be considered.
•
•
Pipe compound should be used which is resistant to the action of liquid
propane gas when gas connections are made.
The gas connections must be firmly attached to rigid, permanent
construction.
Plan View Left Side
Note: The information provided in this manual is general for typical
installations. We cannot cover all possible installation ideas. We recommend,
prior to installation, that you contact your municipality for local building codes
and your local fire department for installation verification.
3
3
/ "
3
4
A (3 / ")
4
Gas Inlet
1
6
/ "
4
1
B (6 / ")
4
C
Gas Inlet
If you have any questions, contact Customer Service at 1-800-446-1071.
Side view
Built-In Gas Line Dimensions
D4
D6
Tolerances
1
A
B
C
3 3
6 1
2 1
/
/
/
"
"
"
3 3/4""
+
+
+
/
/
/
8" - 1
8" - 1
8" - 1
/
/
/
"
8
"
8
"
8
4
4
2
1
1
6 1
2 1
/
"
"
4
2
/
Table
10-1
Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch
Water Column. (Based on a 0.60 Specific Gravity Gas)
Nominal
Iron Pipe
Size
Internal
Diameter
(Inches)
Length of Pipe (Feet)
10
20
30
40
50
60
70
80
90
100
125
150
175
200
(Inches)
1/4
3/8
1/2
3/4
1
.364
.493
32
22
49
18
40
15
34
14
30
12
27
11
25
11
23
10
22
9
8
8
7
6
72
21
18
17
15
14
.622
132
92
73
63
56
50
46
43
40
38
34
31
28
26
.824
278
190
350
730
1100
2100
3300
5900
152
285
590
890
1650
2700
4700
9700
130
245
500
760
1450
2300
4100
8300
115
215
440
670
1270
2000
3600
7400
105
195
400
610
1150
1850
3250
6800
96
90
84
79
72
64
59
55
1.049
1.380
1.160
2.067
2.469
3.068
4.026
520
180
370
560
1050
1700
3000
6200
170
350
530
990
1600
2800
5800
160
320
490
930
1500
2600
5400
150
305
460
870
1400
2500
5100
130
275
410
780
1250
2200
4500
120
250
380
710
1130
2000
4100
110
225
350
650
1050
1850
3800
100
210
320
610
980
1700
3500
1 1/4
1/12
2
1050
1600
3050
4800
8500
2 1/2
3
4
17500 12000
© 1997 National Fire Protection Association, Inc,. and International Approval Services - U.S., Inc. All Rights Reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
GAS SUPPLY
GAS LINE PIPING
TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION
•
•
Refer to the piping chart at the bottom of previous page.
The corrugated gas line from the manifold is 58 inches long. Do not
extend the gas line.
We have provided the means to make an SAE 45° flare connection. Do
not use pipe sealant on this connection.
If the length of line required does not exceed 50 feet, use a 5/8” O.D.
tube. One size larger should be used for lengths greater than 50 feet.
Refer to piping chart.
®
We strongly recommend that you use the Summit Built-In
Tank Cabinet (#21280) for installations using a 20 lb LP cylinder, mounted
remotely in an “island” structure.
The Summit Built-In Tank Cabinet is a CSA listed accessory for installing a
remote mounted 20 lb LP cylinder, in an “island” structure. Summit Built-In
Tank Cabinet has a hose and regulator assembly and gas connections, for
•
•
®
®
®
connecting a remote mounted LP cylinder to the Summit Built-In gas grill. The
hose and regulator is listed as a required part of the CSA listed Summit Built-
®
•
•
Gas piping may be copper tubing, type K or L; polyethylene plastic tube,
with a minimum wall thickness of .062 inch; or standard weight (schedule
40) steel or wrought iron pipe.
Copper tubing must be tin-lined if the gas contains more than 0.3 grams
of hydrogen sulfide per 100 cubic feet of gas.
Plastic tubing is suitable only for outdoor, underground use.
Gas piping in contact with earth, or any other material which may corrode
the piping, must be protected against corrosion in an approved manner.
Underground piping must have a minimum of 18” cover.
In gas grill.
®
The Summit Built-In Tank Cabinet also meets the requirements for venting,
tank retention and separation of the LP cylinder from a heat source as outlined
in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6
for LP enclosures.
The Summit Built-In Tank Cabinet has its own installation guide.
If you do not use the Summit Built-In Tank Cabinet, you need to hire
a licensed contractor or licensed plumber and they need to follow the
requirements described in the ANSI Standard for Outdoor Cooking Gas
Appliances, Z21.58/CSA 1.6 for LP enclosures.
•
•
®
®
•
The requirements described in the Standard for Outdoor Cooking Gas
Appliances, Z21.58/CSA 1.6. are as follows;
A remote enclosure for an LP gas cylinder shall be ventilated by openings at
both the upper and lower levels of the cylinder. This shall be accomplished by
one of the following:
TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance
with local codes and all listed procedures in the latest edition of the National
Fuel Gas Code ANSI Z223.1/NFPA 54.
a). One side of the remote LP cylinder enclosure shall be completely open;
or
ƽ DANGER
b). If the remote LP cylinder enclosure is designed to have four sides, a top
and a bottom, ventilation is required for the remote LP cylinder enclosure;
Do not use an open flame to check for gas leaks. Be
sure there are no sparks or open flames in the area
while you check for gas leaks. This will result in a fire
or explosion which can cause serious bodily injury or
death, and damage to property.
1). There should be at least two ventilation openings, (a hole or group
of holes, for the purpose of ventilation) in the sidewalls of the island
structure. The openings should be located within 5 inches (127mm) of
the top of the enclosure. The ventilation openings should be equally
sized and spaced at a minimum of 90 degrees, and be unobstructed.
The openings shall have a total free open area of not less than 20
square inches. (This relates to 1 square inch of ventilation area, per
pound of stored fuel capacity).
2). Ventilation openings (a hole or group of holes, for the purpose of
ventilation) should be provided at floor level. The ventilation openings
should have a total free area of not less than 10 square inches. (This
relates to 1/2 square inch of ventilation area, per pound of stored
fuel capacity). There should be at least two ventilation openings
if the ventilation openings at floor level are in the sidewall. The
ventilation openings should be within 5 inches (127mm) of the floor.
The ventilation openings should be of equal size and be spaced at a
minimum of 90 degrees, and should be unobstructed.
3). The minimum size of the ventilation hole (s) should not be less than
1/4 inch.
4). The ventilation openings in the sidewalls should not allow venting into
the empty or “hollow” area of the “island”. If a gas leak should occur
or the LP cylinder should vent in the LP cylinder enclosure, the gas
should not be allowed to vent or migrate into the empty or “hollow”
area of the “island”. Ventilation openings in the sidewalls of the
enclosure should only communicate with the outside of the “island”
structure, so that the gas can dissipate outside of the “island” structure.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
GAS SUPPLY
c). If the remote LP cylinder enclosure has four sides, a top and a bottom,
ƽDANGER
and is intended for installation in a built-in “island” enclosure;
1). At least one ventilation opening (a hole or group of holes, for the
purpose of ventilation) needs to be on one side of the enclosure
that communicates with the outside of the “island” structure. If a gas
leak should occur or the LP cylinder should vent in the LP cylinder
enclosure, the gas should not be allowed to vent or migrate into the
empty or “hollow” area of the “island”. Ventilation openings should
only communicate with the outside of the “island” structure, so that
the gas can dissipate outside of the “island” structure. The ventilation
opening should be located within 5 inches (127mm) of the top of the
enclosure, and should have a total free area of 20 square inches. (This
relates to 1 square inch of ventilation area, per pound of stored fuel).
2). At least one ventilation opening (a hole or group of holes, for the
purpose of ventilation) needs to be on one side of the enclosure that
communicates with the outside of the “island” structure, at the bottom.
If a gas leak should occur or the LP cylinder should vent in the LP
cylinder enclosure, the gas should not be allowed to vent or migrate
into the empty or “hollow” area of the “island”. Ventilation openings
should only communicate with the outside of the “island” structure,
so that the gas can dissipate outside of the “island” structure. The
ventilation opening should be located within 5 inches (127mm) of
the bottom of the enclosure, and should have a total free area of 10
square inches. (This relates to 1/4 square inch of ventilation area, per
pound of stored fuel).
Use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply
®
to the Summit Built-In gas grill, and could result in a
fire or an explosion causing serious bodily injury or
death, and damage to property.
ƽDANGER
®
Failure to use the Summit Built-In Tank Cabinet for a
20 lb cylinder or failure to build a LP cylinder enclosure
for a 20 lb cylinder following the requirements for
ventilation, cylinder retention and separation of the LP
cylinder from a heat source, listed in the ANSI Standard
for Outdoor Cooking Gas Appliances, ANSI Z21.58 CSA
1.6, could be dangerous, and could result in a fire or an
explosion causing serious bodily injury or death and
damage to property.
If you do not follow the DANGER statements exactly, the Warranty on the
Summit Built-In gas grill will be voided.
3). The minimum size of the ventilation hole (s) should not be less than
1/4 inch.
®
d). The remote LP cylinder enclosure should be constructed with non-
combustible materials. The remote LP cylinder enclosure should isolate
the LP cylinder from the burner compartment, so that it provides shielding
from radiation, be a flame barrier and provide protection from foreign
material such as hot drippings.
e). There should be a minimum of 2 inches (50.8mm) between the ground
and the floor of the remote LP cylinder enclosure.
f). The LP cylinder valve should be readily accessible for hand operation.
A door on the remote LP cylinder enclosure to gain access to the LP
cylinder valve is acceptable, provided it is non-locking and can be
opened without the use of tools.
If your licensed contractor or licensed plumber builds an LP cylinder enclosure
following the guidelines in the ANSI Standard for Outdoor Cooking Gas
Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287), which will contain the
hose and regulator assembly, mounting bracket for the regulator, connection
fittings and LP tank bracket for retaining the LP cylinder that must be used
®
with the Summit Built-In gas grill. The hose and regulator in the kit (#21287) is
®
listed as part of the CSA listed Summit Built-In gas grill.
ƽ ATTENTION: This product has been safety tested and
is only certified for use in a specific country. Refer to
country designation located on outer carton.
These parts may be gas carrying or gas burning components. Please
contact Weber-Stephen Products Co., Customer Service Department for
genuine Weber-Stephen Products Co. replacement part(s) information.
ƽ WARNING: Do not attempt to make any repair to
gas carrying or gas burning components without
contacting Weber-Stephen Products Co., Customer
Service Department. Your actions, if you fail to follow
this product Warning, may cause a fire or an explosion
resulting in serious personal injury or death and
damage to property.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
GAS SUPPLY
VENTILATION
CONNECT GAS SUPPLY
A 58 inch corrugated gas line is supplied with the grill. This line needs to
pass through the gas inlet opening to the main gas supply.
ƽWARNING: Air holes must be provided in the structure
at the top and bottom to provide ventilation in the event of
a gas leak.
1) Connect the corrugated gas line to the manifold located on the right
hand side of grill under the control panel. Use the 1/2” flared gasket (1)
to ensure proper seal.
Air holes can be located in a low visibility area and should be protected by
screening material to prevent rodents and insects from entering the structure.
Air holes will also help dry moisture.
®
Note: 1/2” flared gaskets are included in the Summit Built-In tank
cabinet (#21280) or the hose and regulator connection from kit # 21287.
®
Summit Built-In cabinet vents are available from your dealer or call Customer
Service at 1-800-446-1071.
Note: Leave an access in the “island” structure for gas supply and regulator
service not inside the grill structure. Weber has a gas line and regulator
access door (part # 36311) available from your dealer or call Customer
Service at 1-800-446-1071.
®
Note: These drawings are only a reference.
•
Cross ventilation must be incorporated in the supporting structure. We
recommend a minimum of 100 square inches of venting per side.
Vents should be on two sides of the structure.
•
OR
Right Side
Left Side
(1)
top view
The corrugated line passes through the “Island Structure” cavity to the
®
regulator connection inside the Summit Built-In tank cabinet (#21280) or the
Front View
hose and regulator connection from kit # 21287. (Shown below)
•
•
•
The above drawings are for reference only.
Location of the vents should be from the center, outward.
Locate the vents at both the bottom of the structure and at the top of the
structure.
•
The bottom vents should be as close to ground level as possible. Make
sure the vent area is not blocked by interior supports of the structure.
We recommend vents with screens.
Access doors to the structure are not considered vents.
Clean the vents periodically.
•
•
•
ƽ DANGER: Failure to follow recommended minimum
venting instructions can cause gas to collect in the
structure in the event of a gas leak. This may result in a
fire or an explosion which can cause serious bodily injury
or death, and damage to property.
Typical tank cabinet
or tank enclosure location
WEBER-STEPHEN PRODUCTS CO.
®
©2006 The following trademarks are registered in the name of Weber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067 U.S.A.
®
®
®
Australia; Smokey Joe, Weber, Kettle Silhouette , Genesis, Austria; Kettle Silhouette , Smokey Joe, Weber, Benelux; Kettle Silhouette , Smokey Joe, Weber, Compact Grill Configura-
®
®
®
tion, Botswana; Weber, Canada; Smokey Joe, Genesis, China; Kettle Silhouette , Denmark; Kettle Silhouette , Smokey Joe, Weber, Finland; Smokey Joe, France; Kettle Silhouette ,
®
Smokey Joe, Weber, One-Touch, Germany; Smokey Joe, Weber, One-Touch, Greece; Smokey Joe, Ireland; Kettle Silhouette , Smokey Joe, Italy; Smokey Joe, Weber, Japan; Smokey
Joe, Weber, Korea; Smokey Joe, Weber, New Zealand; Weber, Smokey Joe, Nigeria; Weber, Norway; Smokey Joe, Weber, Portugal; Weber, South Africa: Smokey Joe, Weber, Kettle
®
®
Configuration, Spain; Smokey Joe, Weber, Sweden; Kettle Silhouette , Smokey Joe, Switzerland; Kettle Silhouette , Smokey Joe, Weber, United Kingdom; Smokey Joe, Weber, Weber
®
One-Touch, U.S.A..; Kettle Configuration, Kettle Silhouette , Smokey Joe, Weber, One-Touch, Firespice, Go-Anywhere, U.S.A.;Kettle Configuration, Kettle Silhouette, Genesis, Fla-
vorizer, Crossover, Flamgo, Performer, Rapidfire, Tuck ‘N Carry, Jumbo Joe, Bar-B-Kettle, Master-Touch, Spirit, Grill Out, Summit, Platinum, 1-800-Grill-Out, Ranch, Matchless Flame,
®
Zimbabwe; Weber, Kettle Configuration, Kettle Silhouette .
Download from Www.Somanuals.com. All Manuals Search And Download.
|