Plasmacluster is a trademarks of SHARP
Corporation.
プラズマクラスターイオン発生機
取扱説明書
IG-A10EK
Plasmacluster Ion Generator
OPERATION MANUAL
この取扱説明書をよくお読みのうえ、
正しくお使いください。
Please read this manual and keep it
somewhere safe.
Download from Www.Somanuals.com. All Manuals Search And Download.
日本語
もくじ
安全上のご注意
......................................................
J-2
J-2
....................................................................
....................................................................
• 警 告
J-2
• 注 意
........................................................
J-2
• ご使用前
の準備
..........................................................
...................................................................................
J-3
J-3
各部のなまえ
• 表示部
.......................................................................................
J-3
• 背面
...............................................................................
J-4
設置場所
.......................................................................
J-4
運転のしかた
...............................................................................
J-5
お手入れ
• 本体
.......................................................................................
J-5
J-5
J-6
............................................................................
......
• フィルター
プラズマクラスターイオン発生ユニットの交換
...............................................................................
J-7
交換方法
....................................................................................
J-8
仕 様
..........................................
J-8
故障かな? ( こんなときは )
当商
品
には浮遊ウイルスなどを、分解・除去する機能はありますが、
これによって無菌状態がつくられるものではなく、感染予防を保証
するものではありません。
•
•
•
この商
品
は安定して高濃度プラズマクラスターイオンを放出するた
めに、定期的※にプラズマクラスターイオン発生ユニットを交換し
ていただく必要
※ 1 日 24 時間運転した場合、約 2 年間 ( 約 17,500 時間 ) です。
約 2 年 2 カ月 ( 約 19,000 時間 ) 経過すると、運転が停止します。
があります。
お買いあげいただき、まことにありがとうございました。
この取扱説明書をよくお読みのうえ、正しくお使いください。
ご使用の前に、「安全上のご注意」 を必ずお読みください。
この取扱説明書は、いつでも見ることができる所に必ず保存してください。
J-1
Download from Www.Somanuals.com. All Manuals Search And Download.
安全上のご注意
必ずお守りください。
お使いになる人や他の人への危害、財産への損害を防止するため、お守りいた
だくことを説明しています。
■表示を無視して、誤った取り扱いをすることによって生じる内容
を次のように
区分しています。
「死亡または重 傷を負うおそ
「けがや財産に損害
を受けるお
禁 止
警 告
れがある」 内容 それがある」 内容です。
です。
してはいけない 「禁止」 内容
必ずしなければいけない 「強制」 内容です。
です。
:
警 告 火災や感電、けがを防ぐ
• ご使用前にお読みください。
• 交流 220-240V 以外では使わない。
• 電源
きは使用しない。
• 電源コードを傷付けたり、無理に曲げたり、引っ張ったり、束ねたり、
い物を乗せたり、加工したりしない。
コード・差込プラグが傷んだり、コンセントの差し込みがゆるいと
重
• 濡れた手で抜き差ししない。
• 改造はしない。修理技術者以外の人は、ユニット交換以外の分解や修理
をしない。
• お手入れ時に塩素系・酸素系の洗剤
を使用しない。
• 次の場所では使用しない。
・ほこりや湿気の多い場所。
・理・美容院、クリーニング店などスプレーや化学薬品を使う場所。
:
注 意 漏電やけがを防ぎ、家財を守る
• プラズマクラスターイオン発生機の近くでは、シリコーンを配合した化
粧品
などは使わない。
• 乳幼児の手の届く範囲では使用しない。
• 差込ブラグのほこりなどは、定期的に取り除く。
• 差込ブラグは、コンセントの奥までしっかり差し込む。
ご使用前の準備
●テレビ・ラジオ・電波時計などから 2m 以上離してください。
J-2
Download from Www.Somanuals.com. All Manuals Search And Download.
各部のなまえ
ルーバー
表示部
(J-4 ページ )
トップカバー
キャップ
ユニット交換ランプ
(J-6 ページ )
( 赤 )
風量 「強」
ランプ
ねじ
( 青
)
吹出口
トップカバー
プラズマクラスター
イオン発生ユニット
( 青
風量 「弱」
ランプ
(J-6,7 ページ )
)
運転切換ボタン
フィルター ( 吸込口 )
フィルター ( 吸込口
)
(J-5 ページ )
背面
プラズマクラスターイオン発
生ユニット交換時
に使用します。
それ以外のときは押
さないでください。
電源コード
前
差込プラグ
J-3
Download from Www.Somanuals.com. All Manuals Search And Download.
設置場所
本体をお部屋の水平な場所に置く。
プラズマクラスターイオン発
生機の近くでは、
必ず安定した平らな台の上に置いてください。
シリコーンを配合した化粧品などは使わない。
シリコーン配合商品には、次のようなものが
ご使用前の準備
あります。
差込プラグをコンセントに差し込む。
殺虫剤
スプレー
ワックス
上方 1m 以上
後方 15cm 以上
左右 20cm 以上
静電気防止剤
ガラスクリーナー、化学ぞうきんなど
、防水スプレー、つや出し剤
運転のしかた
運転切換ボタンを押して電源を入れ、お好みの風量を選んでください。
静かに運転したいとき
風量 「弱」 で運転音を抑えて高濃
度プラズマクラスターイオンを放
出します。
風量 「弱」
強めの風量で運転したいとき
風量 「強」 でプラズマクラスターイオ
ンの濃度をさらに増やし、プラズマク
ラスターイオンの効果を高めます。
風量 「強」
「切 ( 消灯 )
」
運転 「切」
ルーバー
ルーバーの 「△ 」 印の方向へ風が吹き出します。
• お部屋全体にプラズマクラスターイオンを放出したいときは、
左右のルーバーの△の方向を逆向きに取り付けてください。
• 衣類に付着 したニオイを除去したいときなど、1 カ所に集中し
てプラズマクラスターイオンを放出したいときは、左右のルー
バーの△の向きをそろえて取り付けてください。
J-4
Download from Www.Somanuals.com. All Manuals Search And Download.
お手入れ
警 告
お手入れのときは必ず差込プラグをコンセントから抜いてください。
( 感電やけがの原
因 )
Every month or more often if necessary
本 体
.
1 カ月に 1 回程度
柔らかい布で拭き取る。t>
<
>
汚れが落ちにくいとき
台所用合成洗剤を薄めた液に浸した布を固
くしぼって、拭いてください。その後、洗
が残らないように、よく拭き取ってくだ
さい。
剤
フィルター
1 週間に 1 回程度
本体側
面
(2 カ所 ) の吸込口の
<
>
汚れがひどいとき
台所用合成洗剤を薄めた液に浸して破れな
いように軽くもみ洗いしてください。
ほこりを掃除機で吸い取る。
フィルター
フィルター
※フィルターは使い捨てではありません。
ときどき、清掃してください。
J-5
Download from Www.Somanuals.com. All Manuals Search And Download.
プラズマクラスターイオン発生ユニットの交換
この商品は安定して高濃度プラズマクラスターイオンを放出するために、
定期的にプラズマクラスターユニットを交換していただく必要があります。
交換時期をユニット交換ランプでお知らせしますので、交換してください。
表示部
処置
経過時間
点灯
( 青
使い始め
)
ユニット交換時
期が近づいてい
ます。
約 2 年
約 17,500 時間
点滅 ( 赤 )
点灯
( 青
)
•
•
運転が停止します。
プラズマクラス
ターイオン発生
ユニットを交換
してください。
約 2 年 2 カ月
約 19,000 時間
早い点滅
( 赤 )
プラズマクラスター
すべて点滅
イオンが発生しない
※ご使用環境によっては交換時期が終了前に運転が停止することがあります。
そのようなときは、もう一度運転し直してください。それでも、繰り返しエ
ラー表示されるときは、交換用プラズマクラスターイオン発生ユニット ( 別
売 ) に交換してください。
プラズマクラスターイオン発生ユニット
<
>
廃棄
プラズマクラスターイオン発
生ユニット
使用済みのプラズマクラスターイオン発生ユ
ニットは、地域の規制に従って廃棄してくだ
さい。
形名
IZ-CA10E
<
•
•
>
物質
:
ケース ポリスチレン
:
ユニット ポリスチレンテレフタレート、
電子部品
J-6
Download from Www.Somanuals.com. All Manuals Search And Download.
交換方法
※プラズマクラスターイオン発生ユニットの交換時、差込プラグをコンセント
から抜いてください。その際、濡れた手で触らないでください。
ルーバーをはずす
1
トップカバー
キャップをはずす
2
2 つのネジをはずす
3
ネジ
トップカバーを
はずす
4
プラズマクラスター
5
イオン発生機を交換
する
※交換用プラズマクラスターイオン発
生ユニットの取扱説明書をお読み
ください。
J-7
Download from Www.Somanuals.com. All Manuals Search And Download.
仕 様
形 名
IG-A10EK
電 源
220-240V, 50/60Hz
6.5
( 弱 )
( 弱 )
14.0
102
消費電力 (W)
( 強 )
( 強 )
定格風量 (m3/hour)
72
適用床面 10
電源コードの長さ (m)
積 (m2)※
1.8
外形寸法 (mm)
製品重 量 (kg)
140 160 345 (W
2.5
D
H)
※この商
品
を壁際の台の上に置いて、風量「強」運転時に部屋中央付近 ( 床上から高さ 1.2m) の地点で、
空中に吹き出されるイオン個 数が約 25,000 個 /cm3
測定できる部屋の広さの目安です。
故障かな? ( こんなときは )
次のような場合は故障でないことがありますので、修理を依頼される前
にもう一度お調べください。
こんなとき
お調べください
差込プラグがコンセントからはずれていませんか。
運転しない
プラズマクラスターイオン発生ユニットの交換時
期から約 2 カ月 ( 約 1500 時間
) すぎています。
プラズマクラスターイオン発生ユニットを交換し
てください。
点滅 ( 赤 )
点滅 ( 赤 )
プラズマクラスターイオンが発生していません。もう一度
運転切換ボタンを押
して運転しなおしてください。
すべてのランプが点滅し続けているときには、新しいプ
ラズマクラスター発生ユニットと交換してください。
点滅 ( 青
)
•
フィルターにほこりが詰まっていませんか。
フィルターをお手入れしてください。
点滅 ( 青
)
本体の故障です。
差込プラグをコンセントから抜いて、お買いあげ
の販売
店にご連絡ください。
プラズマクラスターイオン発生ユニットで発生
するオゾンのにおいがすることがありますが、
においが出る
健康上、問
題ありません。
プラズマクラスターイオンが発生するときの音
で、異
常ではありません。使用環境や、運転モー
「ジー」 と音がする
ドにより、音が大きく感じたり、聞 こえにくく
感じたりすることがありますが、プラズマクラ
スターイオンの効果は変わりません。
J-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
...............
E-2
...............................................................
• WARNING
E-2
E-2
E-2
......................
• CAUTIONS CONCERNING OPERATION
......................................
• INSTALLATION GUIDELINES
........................................................
.................................................................................
E-3
PARTS NAME
• FRONT
E-3
E-3
...................................................................................
• BACK
...........................................
E-4
E-4
E-5
INSTALLATION POSITION
......................................................................
OPERATION
.............................
CLEANING AND MAINTENANCE
...........................................................................
• MAIN UNIT
E-5
E-5
.................................................................................
• FILTER
....
E-6
E-7
E-8
E-8
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
....
............................................................
....................................................
SPECIFICATIONS
TROUBLESHOOTING
• While IG-A10EK can inactivate and eliminate suspended viruses
and other contaminants, it cannot create a completely sterile envi-
ronment. SHARP does not guarantee its ability to prevent micro-
bial infection.
• To enable stable emission of high-density Plasmacluster ions,
the Plasmacluster Ion Generating Unit mounted in IG-A10EK will
.
need to be replaced periodically*
*Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A10EK will stop operating after about 26 months (19,000 hours) if
the Plasmacluster ion generating unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please
read this manual carefully before using Plasmacluster Ion Generator.
After reading, keep the manual in a convenient location for future reference.
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, fire, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet
is loosened.
• Periodically remove dust from the plug.
• DO NOT insert fingers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or fire from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or fireplaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Center or qualified person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit.
•
DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, in-
cense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may
get wet, such as a bathroom.
• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come
into contact with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or
cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to
avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature
changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may
crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator causes interference to radio or television reception,
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS NAME
FRONT
DISPLAY
Louvers
(See E-4)
Unit Replacing
Top Cover Cap
Screws
(See E-6)
(red)
Light
(blue)
High
Air outlet
Top Cover
Operation
Button
(blue)
Low
Plasmacluster Ion
Generating Unit
(See E-6,7)
Fan Speed
Indicator
Filter (Air Intake)
(See E-5)
Filter (Air Intake)
BACK
Use a pointed object, e.g a pen tip, to press
this button after replacing Plasmacluster Ion
Generating Unit.
Do not press it for any other purpose.
(This is to reset the Unit Replacing Light.)
Power Cord
Plug
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION POSITION
Place the main unit on a smooth,
DO NOT USE the below items near the unit.
stable surface in a room and
insert the plug into an outlet.
silicone-containing products*
DO NOT hold the louvers when carrying the unit.
PESTICIDE
SPRAY
WAX
Installation Guidance.
Leave at least 15cm of clearance behind the Unit.
UPSIDE More than 1m
* Hair care products, cosmetic products,
water proof sprays, polish glass cleaner,
wipe and wax.
BACKSIDE
More than 15cm
LEFT/RIGHT SIDE
More than 20cm
OPERATION
Press the operation button to directly turn on the power and
select the preferred mode.
Release high-density
Plasmacluster ions quietly.
LOW
Release high-density
Plasmacluster ions at high fan
HIGH
speed.
OFF
Power 'OFF'.
Louvers
The air comes from direction, which is stamped on the
louvers.
•When releasing ions to the entire room, put each louver in
an opposite direction.
•When releasing ions to the point to deodorize the adhering
.
odor on clothes, put both louvers in the same direction
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING AND MAINTENANCE
WARNING:
When cleaning the unit, be sure to unplug the power cord first,
and never handle the plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
Main Unit
Every month or more often if necessary
Wipe with a dry soft cloth.
<For Stubborn Dirt>
Use water and a mild detergent. And
rt>
then, wipe with a wet cloth.
Make sure to dry out the main unit.
Filter
Every 2 weeks or more often if necessary
Gently remove dust from the
filters by using a vacuum
cleaner.
<For Stubborn Dirt>
Detach the filter and remove dust with
using a vacuum cleaner.
Filter
Filter
*
The filter is not a disposable item, clean the filter often.
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
To ensure the efficacy of the Plasmacluster Ion Generator it is
necessary to periodically replace the Ion Generating unit.
The unit light will turn on to indicate when replacement is required.
Display
Message
Elapsed Time
From start of use
lighting
(blue)
approx. 2 years
(approx. 17,500hours)
flashing(red)
Suggest replacing
• Stop working
• Replace the
Plasmacluster
Ion Generating
Unit.
lighting
(blue)
approx. 2 years and
2 months
(approx.19,000hours)
flashing faster
(red)
Plasmacluster Ions
are not released.
All light are
flashing
Error*
*Usage environment affects the lifetime of the Plasmacluster Ion Generator.
The Plasmacluster Ion Generator may stop working before estimated lifetime.
In this case, press Operation button again and restart.
If this does not help, replace with a new Plasmacluster Ion Generating Unit.
Plasmacluster Ion Generating Unit for replacement
<For Disposal>
Plasmacluster Ion Generating Unit
Model Number
Please dispose of the used Plasmacluster
Ion Generating Unit according to any local
laws and regulations.
IZ-CA10E
-materials-
• Case : Polystyrene
•
Unit : Polystyrene Terephthalate, Electric
parts
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO REPLACE THE PLASMACLUSTER
ION GENERATING UNIT
*When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the
main unit, unplug the power cord, and never handle the plug with wet hands.
Remove the
LOUVERS.
1
Remove the TOP
COVER CAP.
2
Turn the 2 SCREWS
3
SCREWS
Lift up the TOP
COVER.
4
Replace the
Plasmacluster Ion
Generating Unit.
5
*See the manual of Plasmacluster
Ion Generating Unit for replacement
instructions.
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Model
IG-A10EK
Power supply
220-240V, 50/60Hz
(Low)
(Low)
(Low)
6.5
34
72
14.0
44
Power consumption (W)
Operating noise level (dBA)
Airflow volume(m3/hour)
Applicable floor surface area (m2)*
Power cord (m)
(High)
(High)
(High)
102
10
1.8
Outer dimensions (mm)
Weight (kg)
140 160 345 (W
2.5
D
H)
*The target floor surface area, for which an emitted airborne ion density is of about 25,000 ions/cm3,
can be measured at a point near the center of the room (at a height of about 1.2 m from the floor),
during operation at the HIGH mode when the main unit is placed near a wall.
• The number of ions will vary according to the room conditions and the the main unit operation mode.
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below, since the problem
may not be a Plasmacluster Ion Generator malfunction.
Problem
WHAT TO DO
Make sure the unit is plugged in.
The Plasmacluster Ion Generator
does not work.
Approx. 2 years and 2 months (approx. 19,000
hours) has been passed.
Replace with a new Plasmacluster Ion
Generating Unit. See page E-6,7.
flashing faster
(red)
Plasmacluster Ions are not released.
Press the Operation button and restart.
If all lights keep flashing, replace with new
Plasmacluster Ion Generating Unit. See page E-6,7.
flashing (red)
flashing (blue)
•
Dust may block the filter, clean the filter.
flashing (blue)
Failure
Unplug and contact the store you purchased or
Sharp Service Center.
flashing (blue)
The discharged air has odor.
The Plasmacluster Ion Generator releases a
small trace of ozone which may produce odor.
This is not harmful to health.
A clicking or ticking sound comes
from the unit while operating the
Plasmacluster Ion Generator.
Loudness can be changed depending on a room
humidity, but the effectiveness is the same.
Relocate the Plasmacluster Ion Generator if
necessary.
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION MANUAL
This operation manual contains important information which you should read
carefully before using this product.
If you require any advice or assistance regarding your
Sharp product, please visit our website:
www.sharp.co.uk/customersupport
Customers without Internet access may telephone:
08705 274277 (9am - 5pm)
(01) 676 0648 (from Ireland)
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust
bin!
Used electrical and electronic equipment must be treated separately and in
accordance with legislation that requires proper treatment, recovery and recycling of
used electrical and electronic equipment.
Attention: Your product is
marked with this symbol. It
means that used electrical
and electronic products
should not be mixed with
general household waste.
There is a separate
Following the implementation by member states, private households within the EU
states may return their used electrical and electronic equipment to designated
collection facilities free of charge*. In some countries* your local retailer may also
take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
collection system for these
products.
If your used electrical or electronic equipment has batteries or accumulators, please
dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes
the necessary treatment, recovery and recycling and thus prevent potential negative
effects on the environment and human health which could otherwise arise due to
inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the
correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of
charge to the dealer, even if you don’t purchase a new product. Further collection
B. Information on Disposal for Business Users.
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the
product. You might be charged for the costs arising from take-back and recycling.
Small products (and small amounts) might be taken back by your local collection
facilities.
For Spain: Please contact the established collection system or your local authority for
take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for
the correct method of disposal.
EN
Download from Www.Somanuals.com. All Manuals Search And Download.
GUARANTEE
Sharp Electronics (UK) Ltd. (“Sharp”) guarantees that for a period of 1 year from the date
of purchase the enclosed product will be free from defects in materials and workmanship.
Sharp agrees to provide for the repair or, at its option, the replacement of a defective product.
Sharp reserves the right to replace defective parts, or the product, with new or refurbished items.
Items that are replaced become the property of Sharp.
To benefit from this guarantee, any fault that occurs must be notified to Sharp, or its appointed
Service Facility, within 1 year from the date the product was purchased. Proof of purchase,
such as a receipt or invoice, must be provided.
If the product is exchanged, the replacement shall be covered by the unexpired portion of the
original guarantee.
In the unlikely event of the product requiring repair, please contact the supplier from whom it
was purchased.
Where this is not possible, please contact an appointed Service Facility. Details of Service
service or by contacting the Sharp Customer Information Centre whose details are given
below.
This guarantee shall only apply to faults that are due to inferior workmanship or materials.
It does not cover faults or damage caused by accident, misuse, fair wear and tear,
neglect, tampering with the product, or repair other than by a Service Facility appointed by Sharp.
The guarantee does not cover:
• Carriage costs to or from the repair centre.
No person has any authority to vary the terms or conditions of this guarantee.
This guarantee is offered as an additional benefit to your statutory rights, and does not affect
these rights in any way.
You may not transfer your rights or obligations under this warranty to anyone else.
If you have any difficulty operating the product, or would like information on other Sharp
products, please telephone the Sharp Customer Information Centre on the number given below.
Sharp Customer Information Centre
Website:
Telephone: 08705 274277 (01 676 0648 in Southern Ireland)
Sharp Electronics (UK) Ltd. is a company registered in England under number 965877
whose registered office is at
4 Furzeground Way, Stockley Park, Uxbridge, Middlesex, UB11 1EZ.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
SHARP ELECTRONICS (U.K.) Ltd
4 Furzeground Way, Stockley Park, Uxbridge, Middlesex, UB11 1EZ.
London, U.K.
U.K.: 08705 274277 (office hours)
Ireland: 01 676 0648 (office hours)
Printed in China
CN
1
TINS-A358KKRZ 09J-
Download from Www.Somanuals.com. All Manuals Search And Download.
|