Sanyo Car Stereo System CH1822 User Guide

SERVICE MANUAL (Basic Information)  
KHS1822 / CH1822  
SPLIT SYSTEM AIR CONDITIONER  
Indoor Unit  
Outdoor Unit  
HIGH  
EFFICIENCY  
KHS1822  
CH1822  
8526481021800  
REFERENCE NO. WM700796  
W
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE MANUAL  
KHS1822 / CH1822  
(Basic Information)  
WM700796  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When Transporting  
IMPORTANT!  
Please Read Before Starting  
Be careful when picking up and moving the indoor and out-  
door units. Get a partner to help, and bend your knees when  
lifting to reduce strain on your back. Sharp edges or thin  
aluminum fins on the air conditioner can cut your fingers.  
This air conditioning system meets strict safety and operating  
standards. As the installer or service person, it is an important  
part of your job to install or service the system so it operates  
safely and efficiently.  
When Installing…  
…In a Ceiling or Wall  
For safe installation and trouble-free operation, you must:  
Make sure the ceiling/wall is strong enough to hold the  
unit’s weight. It may be necessary to construct a strong  
wood or metal frame to provide added support.  
G
Carefully read this instruction booklet before beginning  
G
Follow each installation or repair step exactly as shown  
G
Observe all local, state, and national electrical codes  
…In a Room  
Properly insulate any tubing run inside a room to prevent  
“sweating” that can cause dripping and water damage to  
walls and floors.  
G
Pay close attention to all warning and caution notices  
given in this manual  
This symbol refers to a hazard or  
…In Moist or Uneven Locations  
unsafe practice which can result  
in severe personal injury or  
death.  
WARNING:  
CAUTION:  
Use a raised concrete pad or concrete blocks to provide a  
solid, level foundation for the outdoor unit. This prevents  
water damage and abnormal vibration.  
This symbol refers to a hazard or  
unsafe practice which can result  
in personal injury or product or  
property damage.  
…In an Area with High Winds  
Securely anchor the outdoor unit down with bolts and a  
metal frame. Provide a suitable air baffle.  
If Necessary, Get Help  
…In a Snowy Area (for Heat Pump-type Systems)  
Install the outdoor unit on a raised platform that is higher  
than drifting snow. Provide snow vents.  
These instructions are all you need for most installation  
sites and maintenance conditions. If you require help for a  
special problem, contact our sales/service outlet or your  
certified dealer for additional instructions.  
When Connecting Refrigerant Tubing  
• Keep all tubing runs as short as possible.  
• Use the flare method for connecting tubing.  
In Case of Improper Installation  
The manufacturer shall in no way be responsible for  
improper installation or maintenance service, including  
failure to follow the instructions in this document.  
• Apply refrigerant lubricant to the matching surfaces of the  
flare and union tubes before connecting them, then tighten  
the nut with a torque wrench for a leak-free connection.  
SPECIAL PRECAUTIONS  
When Wiring  
• Check carefully for leaks before starting the test run.  
NOTE:  
Depending on the system type, liquid and gas lines may be  
either narrow or wide. Therefore, to avoid confusion the  
refrigerant tubing for your particular model is specified as  
either “narrow” or “wide” rather than as “liquid” or “gas.”  
ELECTRICAL SHOCK CAN CAUSE SEVERE PER-  
SONAL INJURY OR DEATH. ONLY A QUALIFIED,  
EXPERIENCED ELECTRICIAN SHOULD  
ATTEMPT TO WIRE THIS SYSTEM.  
• Do not supply power to the unit until all wiring and tub-  
ing are completed or reconnected and checked.  
When Servicing  
• Turn the power OFF at the main power box (mains)  
before opening the unit to check or repair electrical parts  
and wiring.  
• Highly dangerous electrical voltages are used in this sys-  
tem. Carefully refer to the wiring diagram and these  
instructions when wiring. Improper connections and inad-  
equate grounding can cause accidental injury or death.  
• Keep your fingers and clothing away from any moving  
parts.  
• Ground the unit following local electrical codes.  
• Clean up the site after you finish, remembering to check  
that no metal scraps or bits of wiring have been left  
inside the unit being serviced.  
• Connect all wiring tightly. Loose wiring may cause over-  
heating at connection points and a possible fire hazard.  
WM700796  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Page  
1
1. OPERATING RANGE...............................................................................................................................  
2. SPECIFICATIONS ....................................................................................................................................  
2
2
Unit Specifications .......................................................................................................................................  
3. DIMENSIONAL DATA .............................................................................................................................  
4. COOLING CAPACITY.............................................................................................................................  
5. HEATING CAPACITY..............................................................................................................................  
6. REFRIGERANT FLOW DIAGRAM ......................................................................................................  
7. ELECTRICAL DATA................................................................................................................................  
3
4
6
8
9
9
G
Electrical Characteristics .......................................................................................................................  
Electric Wiring Diagram........................................................................................................................  
G
10  
WM700796  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. OPERATING RANGE  
KHS1822 / CH1822  
Temperature  
Indoor Air Intake Temp.  
95°F DB / 71°F WB  
67°F DB / 57°F WB  
80°F DB / 67°F WB  
— DB / — WB  
Outdoor Air Intake Temp.  
115°F DB  
Maximum  
Cooling  
Minimum  
67°F DB  
Maximum  
Heating  
75°F DB / 65°F WB  
17°F DB / 15°F WB  
Minimum  
WM700796  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. SPECIFICATIONS  
Unit Specifications  
Indoor unit  
KHS1822  
CH1822  
Model No.  
Outdoor unit  
Cooling  
16,500 / 16,000  
4.84 / 4.69  
Heating  
18,000 / 17,600  
5.27 / 5.16  
BTU/h  
Capacity  
kW  
Air circulation (High)  
Moisture removal (High)  
Phase, Frequency  
Voltage rating  
Available voltage range  
Running amperes  
Power input  
cu. ft/min.  
440 / 420  
5.3 / 5.2  
Pints/h  
Hz  
Single, 60  
V
230 / 208  
187 to 253  
8.0 / 8.6  
230 / 208  
187 to 253  
8.0 / 8.6  
V
A
W
%
1,810 / 1,760  
98 / 98  
1,810 / 1,760  
98 / 98  
Power factor  
Starting amperes  
S.E.E.R. (H.S.P.F.)  
Heat element  
A
52  
BTU/Wh  
kW  
10.0 / 10.0  
(6.8 / 6.8)  
1.80 / 1.47  
Controls  
Microprocessor  
Control unit  
Wireless remote control unit  
IC thermostat  
ON/OFF 24-hours & Program  
3 and Auto / 1  
Manual / Automatic  
Washable, easy access  
Rotary  
Temperature control  
Timer  
Fan speeds  
Indoor / Outdoor  
Air deflector  
Horizontal / Vertical  
Air filter  
Compressor  
Refrigerant amount charged at shipment  
lbs. (kg)  
R22: 4.25 (1.93)  
Capillary tube  
Flare type  
Refrigerant control  
Refrigerant tubing connections  
In-Hi / Me / Lo  
Out-Hi  
dB-A  
dB-A  
47 / 44 / 40  
Operation sound  
55  
Max. allowable tubing length at shipment  
Limit of tubing length  
ft. (m)  
ft. (m)  
ft. (m)  
33 (10)  
65 (20)  
Limit of elevation difference  
between the 2 units  
Outdoor unit is higher than indoor unit: 23 (7)  
Outdoor unit is lower than indoor unit: 23 (7)  
Narrow tube  
in. (mm)  
in. (mm)  
1/4 (6.35)  
5/8 (15.88)  
Refrigerant tube o.d.  
Wide tube  
Refrigerant tube kit  
Accessories  
Optional  
Hanging wall bracket  
Indoor unit  
14-3/16 (360)  
38-31/32 (990)  
7-25/32 (198)  
30 (13.5)  
Outdoor unit  
24-13/16 (630)  
32-11/16 (830)  
12-13/32 (315)  
134 (61)  
Height  
in. (mm)  
in. (mm)  
Width  
Depth  
in. (mm)  
Net weight  
lbs. (kg)  
Shipping volume  
Shipping weight (Approx.)  
cu. ft. (cu. m)  
lbs. (kg)  
4.8 (0.136)  
10.4 (0.294)  
143 (65)  
37.4 (17)  
DATA SUBJECT TO CHANGE WITHOUT NOTICE.  
Remarks: Rating conditions are:  
Cooling: Outside air temperature 95°F DB/75°F WB  
Indoor unit entering air temperature 80°F DB/67°F WB  
Heating: Outside air temperature 47°F DB/43°F WB  
Indoor unit entering air temperature 70°F WB  
WM700796  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. DIMENSIONAL DATA  
Indoor Unit: KHS1822  
14-3/16  
38-31/32  
7-25/32  
Rear panel  
(Center point of gravity)  
Wireless remote  
control unit  
1-61/64  
2-13/64  
19/32  
Drain hose O.D. 1-1/4  
Narrow tube O.D. 1/4  
5-19/32  
Center of  
tubing hole  
(For right rear)  
Wide tube O.D. 5/8  
Outdoor Unit: CH1822  
21-3/16  
5-3/4  
Air intake  
Air  
intake  
4 × 15/32 dia. hole  
Check port  
Air discharge  
32-11/16  
1/4 narrow tubing  
service valve  
2-1/4  
1-3/16  
5/8 wide tubing  
service valve  
11-7/32  
2-3/8  
3-3/4  
3/4  
WM700796  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. COOLING CAPACITY  
230V  
KHS1822 / CH1822  
Rating Capacity: 16,500 BTU/H  
Evaporator  
Air Flow Rate: 440 CFM  
Condenser  
Ent. Temp. °F/(°C)  
Ambient Temp.  
°F/(°C)  
75  
(23.9)  
85  
(29.4)  
95  
(35.0)  
105  
(40.6)  
115  
(46.1)  
WB  
DB  
TC  
kW  
16,340  
1.31  
15,590  
1.43  
14,850  
1.56  
14,010  
1.69  
12,870  
1.86  
59  
(15.0)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
11,540  
12,910  
14,340  
15,720  
16,340  
11,140  
12,510  
13,950  
15,320  
15,590  
10,750  
12,130  
13,560  
14,850  
14,850  
10,320  
11,700  
13,130  
14,010  
14,010  
9,760  
11,130  
12,560  
12,870  
12,870  
TC  
kW  
16,900  
1.32  
16,370  
1.45  
15,720  
1.58  
14,870  
1.72  
13,700  
1.90  
63  
(17.2)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
9,780  
11,150  
12,590  
13,960  
15,330  
9,520  
10,890  
12,330  
13,700  
15,070  
9,210  
10,580  
12,020  
13,390  
14,760  
8,810  
10,180  
11,610  
12,990  
14,360  
8,270  
9,640  
11,070  
12,440  
13,700  
TC  
kW  
17,360  
1.34  
17,080  
1.46  
*16,500  
1.60  
15,590  
1.74  
14,520  
1.94  
67  
(19.4)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
7,960  
9,330  
10,770  
12,140  
13,510  
7,840  
9,210  
10,640  
12,010  
13,390  
7,580  
8,950  
10,390  
11,760  
13,130  
7,190  
8,560  
9,990  
11,370  
12,740  
6,730  
8,100  
9,540  
10,910  
12,280  
TC  
kW  
17,900  
1.35  
17,610  
1.48  
17,160  
1.62  
16,380  
1.79  
15,430  
1.98  
71  
(21.7)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
6,090  
7,460  
8,900  
10,270  
11,640  
5,970  
7,340  
8,780  
10,150  
11,520  
5,790  
7,170  
8,600  
9,970  
11,350  
5,490  
6,860  
8,300  
9,670  
11,040  
5,120  
6,490  
7,930  
9,300  
10,670  
TC  
kW  
18,250  
1.38  
18,050  
1.50  
17,660  
1.65  
17,030  
1.83  
16,340  
2.02  
75  
(23.9)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
5,600  
7,030  
8,400  
9,780  
5,530  
6,960  
8,330  
9,700  
5,380  
6,820  
8,190  
9,560  
5,160  
6,590  
7,970  
9,340  
4,920  
6,350  
7,720  
9,100  
TC: Total Cooling Capacity (BTU/H)  
SHC: Sensible Heat Capacity (BTU/H)  
kW: Compressor Input (kW)  
Remarks: Rating conditions (* mark) are: Outdoor ambient temperature 95°F DB  
Indoor unit entering air temperature 80°F DB/67°F WB  
WM700796  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
208V  
KHS1822 / CH1822  
Rating Capacity: 16,000 BTU/H  
Air Flow Rate: 420 CFM  
Condenser  
Evaporator  
Ent. Temp. °F/(°C)  
Ambient Temp.  
°F/(°C)  
75  
(23.9)  
85  
(29.4)  
95  
(35.0)  
105  
(40.6)  
115  
(46.1)  
WB  
DB  
TC  
kW  
15,840  
1.28  
15,120  
1.40  
14,400  
1.52  
13,580  
1.65  
12,480  
1.81  
59  
(15.0)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
11,180  
12,500  
13,880  
15,200  
15,840  
10,800  
12,120  
13,500  
14,820  
15,120  
10,420  
11,740  
13,120  
14,400  
14,400  
10,000  
11,320  
12,700  
13,580  
13,580  
9,450  
10,770  
12,150  
12,480  
12,480  
TC  
kW  
16,380  
1.29  
15,870  
1.42  
15,250  
1.54  
14,420  
1.68  
13,280  
1.85  
63  
(17.2)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
9,490  
10,810  
12,190  
13,510  
14,830  
9,240  
10,560  
11,940  
13,260  
14,580  
8,930  
10,250  
11,640  
12,960  
14,280  
8,540  
9,860  
11,240  
12,560  
13,880  
8,010  
9,330  
10,720  
12,040  
13,280  
TC  
kW  
16,830  
1.30  
16,560  
1.43  
*16,000  
1.56  
15,120  
1.70  
14,080  
1.89  
67  
(19.4)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
7,730  
9,050  
10,430  
11,750  
13,080  
7,610  
8,930  
10,310  
11,630  
12,950  
7,360  
8,680  
10,060  
11,380  
12,710  
6,980  
8,300  
9,680  
11,000  
12,320  
6,540  
7,860  
9,240  
10,560  
11,880  
TC  
kW  
17,360  
1.32  
17,070  
1.44  
16,640  
1.58  
15,890  
1.75  
14,960  
1.93  
71  
(21.7)  
72 (22.2)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
SHC  
5,930  
7,250  
8,630  
9,950  
11,270  
5,810  
7,130  
8,520  
9,840  
11,160  
5,640  
6,960  
8,340  
9,660  
10,980  
5,340  
6,660  
8,050  
9,370  
10,690  
4,980  
6,300  
7,690  
9,010  
10,330  
TC  
kW  
17,700  
1.34  
17,500  
1.47  
17,120  
1.61  
16,510  
1.79  
15,840  
1.97  
75  
(23.9)  
76 (24.4)  
80 (26.7)  
84 (28.9)  
88 (31.1)  
SHC  
SHC  
SHC  
SHC  
5,450  
6,830  
8,150  
9,470  
5,380  
6,760  
8,080  
9,400  
5,240  
6,620  
7,940  
9,260  
5,020  
6,410  
7,730  
9,050  
4,790  
6,170  
7,490  
8,810  
TC: Total Cooling Capacity (BTU/H)  
SHC: Sensible Heat Capacity (BTU/H)  
kW: Compressor Input (kW)  
Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB  
Indoor unit entering air temperature 80°F DB/67°F WB  
WM700796  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. HEATING CAPACITY  
1 Phase 60Hz 230V  
Indoor Entering Air Temperature 70°F  
30,000  
25,000  
24,120  
20,000  
18,000  
15,000  
10,000  
5,000  
17  
(–8.3)  
23  
(–5)  
32  
(0)  
41  
(5)  
47 50  
(8.3)  
59  
(15)  
68  
(20)  
75°F  
(23.7°C)  
Temperature of Air Entering Outdoor Coil  
(°F DB at 75% RH)  
WM700796  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Phase 60Hz 208V  
Indoor Entering Air Temperature 70°F  
30,000  
25,000  
22,640  
20,000  
17,600  
15,000  
10,000  
5,000  
17  
(8.3)  
23  
(5)  
32  
(0)  
41  
(5)  
47 50  
(8.3)  
59  
(15)  
68  
(20)  
75°F  
(23.7°C)  
Temperature of Air Entering Outdoor Coil  
(°F DB at 75% RH)  
WM700796  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. REFRIGERANT FLOW DIAGRAM  
Cooling Cycle  
Wide tube  
service  
valve  
Accumulator  
Wide tube  
Disharge pressure  
regulator  
O.D.  
5/8"  
P
(ø15.88 mm)  
Muffler  
4-way  
valve  
Muffler  
Indoor unit  
Muffler  
Capillary  
Narrow tube  
service  
valve  
Narrow tube  
Check  
port  
Capillary  
O.D.  
1/4"  
(ø6.35 mm)  
(
)
Strainer  
Check Drier  
valve  
Outdoor unit  
Heating Cycle  
Wide tube  
service  
valve  
Accumulator  
Wide tube  
Disharge pressure  
regulator  
O.D.  
5/8"  
(ø15.88 mm)  
P
4-way  
valve  
Muffler  
Capillary  
Narrow tube  
service  
valve  
Narrow tube  
Check  
port  
Capillary  
O.D.  
1/4"  
(
)
(ø6.35 mm)  
Strainer  
Check Drier  
valve  
Indoor unit  
Outdoor unit  
WM700796  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. ELECTRICAL DATA  
G Electrical Characteristics  
KHS1822 / CH1822  
Performance at  
Indoor Unit  
Outdoor Unit  
Complete Unit  
230/208V – 1ø – 60Hz  
Fan Motor  
Max. Heat  
Fan Motor  
Compressor  
7.13 / 7.73  
1,595 / 1,564  
7.13 / 7.73  
1.595 / 1.574  
52  
Heat-pump  
Max. Heat  
A
W
A
0.40 / 0.40  
90 / 81  
0.47 / 0.47  
105 / 95  
8.0 / 8.6  
1,790 / 1,740  
8.0 / 8.6  
Rating  
Conditions  
Cooling  
0.40 / 0.40  
90 / 81  
7.8 / 7.1  
1,800 / 1,470  
0.47 / 0.47  
105 / 95  
15.8 / 15.7  
3,590 / 3,220  
Rating  
Conditions  
Heating  
W
A
1,790 / 1,750  
Locked-Rotor Amperes  
0.45 / 0.40  
0.71 / 0.64  
Remarks: Rating conditions are:  
Cooling: Outside air temperature 95°F DB/75°F WB  
Indoor unit entering air temperature 80°F DB/67°F WB  
Heating: Outside air temperature 47°F DB/43°F WB  
Indoor unit entering air temperature 70°F WB  
WM700796  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
G Electric Wiring Diagram  
WARNING:  
To avoid electrical shock hazard, be sure to  
disconnect power before checking, servicing  
and/or cleaning any electrical parts.  
Indoor Unit: KHS1822  
Terminal plate  
Thermistor  
Transformer  
1
2
3
4
BLK  
WHT  
ORG  
YEL  
S
P
Noise  
filter  
3 1  
3 1  
3 2 1  
3 2 1  
1 2  
1 2  
1 2  
1 2  
1 1  
2 2  
G
SG-OUT 3P  
SUP  
HR  
2P  
2P  
TH1  
TH2  
1 1  
2 2  
BLU  
2P  
1 1  
2 2  
4
3
5
6
2
Heater  
relay  
1 RY  
2P  
CONTROLLER  
2 2  
1 1  
Switch  
assy  
H. THERMO  
2 2  
1 1  
FM H M  
L
LL  
1
9
2 1  
2 1  
1
1
9
9
1 2  
1 2  
YEL  
YEL  
Connector  
1 2  
1 2  
Switch  
assy  
1 2 3  
1 2 3  
4
4
1 2  
1 2  
Receiver  
assy  
Louver  
motor  
LM  
Thermo  
fuse  
Thermostat  
BRN  
PNK  
FM  
Resistor  
Heater assy  
GRN  
Fan  
motor  
G
WM700796  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Outdoor Unit: CH1822  
WARNING:  
To avoid electrical shock hazard, be sure to  
disconnect power before checking, servicing  
and/or cleaning any electrical parts.  
Solenoid  
coil  
Connector  
Power transformer  
BLK  
BLK  
1 1  
2 2  
PNK  
BLK  
WHT  
SC  
P
S
WHT  
Noise filter  
BLK  
BRN  
BRN  
TH1  
TH2  
TH3  
1 2  
1 2  
1 2  
1 2  
Terminal  
plate  
WHT  
Thermistor (coil)  
2P  
PRY  
2P  
SEC  
1 1  
2 2  
SC1 SC2  
BLK  
BLK  
1
1 1  
2P  
2 2 SUP  
2
3
4
5
6
WHT  
ORG  
YEL  
Thermistor (air temp)  
1 1  
3 3  
SG-IN  
1 1  
2 2  
BLK  
BLK  
BLK  
CONTROLLER  
Thermistor (discharge)  
BLK  
BLK  
WHT  
1 1  
2 2  
G
1 1  
2 2  
LO  
PRS  
HI  
PRS  
1 2  
RED  
CT  
2P  
CM  
1 2  
1 2  
H FM  
L
1 2  
Power  
relay  
BLU  
Crank case  
heater  
COM  
Capacitor  
Connector  
NC  
NO  
Starting  
relay  
GRY  
6 5 4 3 2 1  
6 5 4 3 2 1  
1
3
RED  
2
C
BLK  
Compressor  
motor  
FM  
CM  
Fan motor  
R
S
BLK  
BLK  
BLK  
Capacitor  
Capacitor  
WHT  
WHT  
WM700796  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For parts or service contact  
SFS Corporation: 1200 West Artesia Blvd., Compton, California 90220  
CORPORATION  
In Canada  
SANYO Canada Inc.: Toronto, Ont. M4H 1M6  
H408/12M  
Printed in U.S.A.  
WM700796  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Car Speaker 40 215 User Guide
Renesas Network Card R0E53033ACFG90 User Guide
Roland MP3 Player AR 3000R User Guide
Roland Musical Instrument Amplifier CUBE 80X User Guide
Roland Musical Instrument Studio Package Pro User Guide
Samsung Computer Hardware M471B1G73AH0 User Guide
Samsung Laptop NP600B4CA01US User Guide
Samsung Printer SCX 6x22 User Guide
Samsung Printer SF 76xP Series User Guide
Satco Products Indoor Fireplace CF260E B User Guide