RuggedSwitch RS969
Installation Guide
RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4
Tel: 905-856-5288 I Fax: 905-856-1995 I Toll Free: 1-888-264-0006
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1
2
Product Overview.....................................................................................................................4
1.1 RS969 Family Ports/Connectors Description.................................................................. 5
Installation................................................................................................................................7
2.1
2.2
2.3
DIN Rail Mounting........................................................................................................... 7
Ingress Protection IP67 .................................................................................................. 8
Power Supply Wiring and Grounding.............................................................................. 9
2.3.1 Power Supply Input Connectors Description .............................................................. 9
2.3.2 Single AC Power Supply Wiring Examples............................................................... 12
2.3.3 Single DC Power Supply Wiring Examples .............................................................. 13
2.3.4 Dual Power Supplies – DC and AC Inputs ............................................................... 14
2.4
Dielectric Strength (HIPOT) Testing ............................................................................. 16
Failsafe Alarm Relay Wiring and Specifications............................................................ 17
Console Port Wiring...................................................................................................... 18
Fast Ethernet Ports – Signal Description...................................................................... 19
2.5
2.6
2.7
3
Technical Specifications.........................................................................................................20
3.1
Operating Environment................................................................................................. 20
Power Supply Specifications......................................................................................... 20
Failsafe Relay Specifications........................................................................................ 20
Twisted Pair Data Port Specifications........................................................................... 21
Fiber Optical Port Specifications................................................................................... 21
IEC 61850-3 Type Tests............................................................................................... 22
IEEE 1613 Type Tests.................................................................................................. 23
IEC Environmental Type Tests ..................................................................................... 23
Mechanical Specifications ............................................................................................ 24
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10 Agency Approvals......................................................................................................... 26
Accessories............................................................................................................................27
4.1 POWER (1/unit)................................................................................................................... 27
4.2 CONSOLE (1/unit)............................................................................................................... 27
4.3 FAILSAFE (1/unit)................................................................................................................ 28
4.4 ETHERNET (8/unit) ............................................................................................................. 29
4.5 LC FIBER OPTIC (2/unit)..................................................................................................... 30
Warranty.................................................................................................................................31
4
5
3
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Product Overview
The RuggedSwitch™ RS969 is an industrially hardened, fully managed Ethernet switch providing
dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports in an IP65/IP67
rated package for protection against low pressure jets of water (IP65) or temporary immersion in
water (IP67). Designed to operate reliably in harsh industrial environments the RS969 provides a
high level of immunity to electromagnetic interference and heavy electrical surges typical of
environments found in electric utility substations, factory floors or in curb side traffic control
cabinets. An operating temperature range of -40°C to +85°C coupled with hazardous location
certification and IP65/IP67 rated waterproof packaging allows the RS969 to be placed in virtually
any location. The embedded Rugged Operating System (ROS™) provides advanced networking
features such as Enhanced Rapid Spanning Tree (eRSTP™), Port Rate Limiting and a full array
of intelligent functionality for high network availability and manageability.
Ethernet Ports
Universal Power Supply Options
• Fully integrated power supply
• 2 - Fiber Optical Gigabit Ethernet Ports
(1000BaseX) with:.IP65/IP67 Rated fiber
optical connectors (type LC)
• Universal high-voltage range: 88-300VDC or
85-264VAC• Popular low-voltage DC ranges:
12, 24, 48 VDC
• 8 - Fast Ethernet Ports (10/100BaseTX) with
IP65/IP67 Rated M12 D-code connectors or
IP65/IP67 Rated shrouded RJ45 style
connectors
• Dual redundant, parallel load-sharing power
supplies (option)
• Can be powered from different sources for
ultimate redundancy
• Full compliance with IEEE: 802.3, 802.3u
and 802.3z
• Available with M12 or M23 style connectors
• CSA/UL 60950 safety approved to +85°C
• Non-blocking, store and forward switching
• Full duplex operation and flow control (IEEE
802.3x)
Simple Plug and Play Operation
• Automatic learning of up to 8192
MAC addresses
RuggedRated™ for Reliability in Harsh
Environments
• Auto-negotiation on all 10/100BaseTX ports
• Auto-MDI/MDIX (crossover) on all
10/100BaseTX ports
• IP67 Rated for protection against immersion
in water
• IP66 Rated for protection against high
pressure jets of water
• LED indicators for link and activity
• Meets IEEE 1613 (electric utility substations)
• Exceeds IEC 61850-3
(electric utility substations)
ROS™ Advanced Network Management
• Enhanced Rapid Spanning Tree (eRSTPTM)
• Quality of Service (802.1p) for real-time
traffic
• Exceeds IEEE 61800-3
(variable speed drive systems)
• Exceeds IEC 61000-6-2
(generic industrial environment)
• Exceeds NEMA TS-2
(traffic control equipment)
• Port rate limiting: 128kbps to 8Mbps
• VLAN (802.1q) with double tagging
• IGMP Snooping for multicast filtering
• Port configuration, status, statistics,
mirroring, security
• -40 to +85°C operating temperature (no fans)
• Conformal coated circuit boards (optional)
• Loss of link management on fiber ports
• Web-based, Telnet, CLI management
interfaces
• SNMP v2 and RMON
• Rich set of diagnostics with logging and
alarms
4
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1 RS969 Family Ports/Connectors Description
Figure 1.1.1 RS969–M12 with Mini-Change Power Connector
5
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 1.1.2 RS969–RJ45 with M23 Power Connector
ITEM
LINK LED (Yellow)
Activity
Solid
Blinking
Solid
Solid
Solid
Comments
Link Established
Tx/Rx Activity
Power 1 LED
Power 2 LED
Alarm LED (Red)
Power Supply 1 On
Power Supply 2 On
Alarm condition exists
6
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2 Installation
2.1 DIN Rail Mounting
An optional DIN rail mounting bracket is available for the RS969. Figure 2.1.1 details mounting
instructions for the standard 1” DIN Rail.
Optional
DIN Rail
DIN
Mounting
Rail
Bracket
Release
Latch
Release Direction
Figure 2.1.1 RS969 Family DIN Rail Mounting
7
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Ingress Protection IP67
IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection
provided by enclosures as a system for specifying the enclosures of electrical equipment on the
basis of the degree of protection provided by the enclosure." These ratings are determined by
specific tests
The IP number is composed of two numbers, the first referring to the protection against solid
objects and the second against liquids. The higher the IP number, the better the protection. The
chart below defines levels of IP ratings.
1st
IP#
Degree of protection against access to
hazardous parts & ingress of solid objects
2nd
IP#
Degree of protection against the
ingress of water
0
1
No protection
0
1
No protection
Protected against solid foreign objects of 50 mm Ø
and >
Protected against vertically falling water drops
Protected against solid foreign objects of 12.5 mm Ø
and >
Protected against vertically falling water drops
when enclosure titled up 15°
2
3
4
2
3
4
Protected against solid foreign objects of 2.5 mm Ø
and >
Protected against spraying water
Protected against splashing water
Protected against solid foreign objects of 1.0 mm Ø
and >
5
6
Dust protected
Dust tight
5
6
Protected against jet-water
Protected against strong jet-water
Protected against the effects of temporary
submersion in water
7
8
Protected against the effects of permanent
submersion in water
The RuggedCom M969 Industrial Ethernet Switch is manufactured and tested to IP67 standards.
With an IP67 rating a product will be "dust tight" and remain completely sealed when immersed in
water to a depth of 1 meter for 1 hour. (IEC 60529)
These caps completely seals off unused ports on the IP67 Industrial
Ethernet Switch. It has an IP67 rated seal that keeps out all
contaminants like dirt, oil, and water.
8
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3 Power Supply Wiring and Grounding
2.3.1 Power Supply Input Connectors Description
Mini power supply connector
M23 power supply connector
Figure 2.2.1.1 RS969 Family Power Supply Inputs
S u rge
G ro u n d
C h assis
G ro u n d
Figure 2.2.1.2 RS969 Family Surge Ground / Chassis Ground Connection
9
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
The RS969 family has 2 different power supply input connectors---Mini A-coded male connector or
M23 A-code male connector shown in Figure 2.2.1.1. The Mini power connector only has 4
terminals, so only one power supply source is allowed to connect to the RS969 with Mini power
connector; The M23 power connector has 5 terminal pins which means 2 power supply sources are
allowed to power the RS969 with M23 power connector.
The RS969 family supports dual redundant power supplies – “Power Supply 1 (PS1)” and “Power
Supply 2 (PS2)”. The connections for PS1, PS2 are shown in Table1 and 2.
Refer to
Table 1 and 2 for a description of each terminal and sections 2.3.2 through 2.3.4 for wiring
examples.
Terminal #
Description
Usage
PS1 Live / + is connected to the positive (+) terminal if the
PS1 Live / + power source is DC or to the (Live) terminal if the power
source is AC.
1
PS1 Neutral / - is connected to the negative (-) terminal if
PS1 Neutral / - the power source is DC or to the (Neutral) terminal if the
power source is AC.
2
3
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
inputs. This terminal 3 is connected to chassis ground
internally in the RS969 family. There is also an additional
chassis ground screw and the chassis ground connects to
Chassis
Ground
both power supply surge grounds via a removable jumper
shown in Figure 2.2.1.2 .
PS2 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
4
5
PS2 Live / +
PS2 Neutral / - is connected to the negative (-) terminal if
PS2 Neutral / - the power source is DC or to the (Neutral) terminal if the
power source is AC.
Table 1: RS969 Power terminal block connection description for M23 A-code male connector
10
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminal #
Description
Usage
PS1 Live / + is connected to the positive (+) terminal if the
PS1 Live / + power source is DC or to the (Live) terminal if the power
source is AC.
1
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
inputs. This terminal 3 is connected to chassis ground
internally in the RS969 family. There is also an additional
chassis ground screw and the chassis ground connects to
2
3
Chassis
Ground
both power supply surge grounds via a removable jumper
shown in Figure 2.2.1.2 .
PS1 Neutral / - is connected to the negative (-) terminal if
PS1 Neutral / - the power source is DC or to the (Neutral) terminal if the
power source is AC.
4
Table 2: RS969 Power terminal block connection description for Mini A-coded male connector
NOTES:
1. Equipment must be installed according to the applicable country wiring codes.
2. Surge Ground must be disconnected from the Chassis Ground during HIPOT (dielectric
strength) testing.
3. All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases
where users require the inputs to be isolated from ground, remove the ground braid
between Surge and Chassis Ground. All line-to-ground transient protection circuitry will be
disabled.
11
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.2 Single AC Power Supply Wiring Examples
Figure 1: AC Power supply wiring examples
NOTES:
1. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be
installed within 3m of unit.
2. Equipment must be installed according to the applicable country wiring codes.
3. When equipped with two HI voltage power supplies, independent AC sources can be used
to power the product for greater redundancy.
12
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.3 Single DC Power Supply Wiring Examples
Figure 2: DC Power supply wiring examples
NOTES:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be
installed within 3m of unit.
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
3. For dual DC power supplies, Separate circuit breakers must be installed and
separately identified.
4. Equipment must be installed according to the applicable country wiring codes.
13
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.4 Dual Power Supplies – DC and AC Inputs
14
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 3: DC And AC power supply wiring examples
NOTES:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be
installed within 3m of unit.
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
3. Separate circuit breakers must be installed and separately identified.
4. Equipment must be installed according to the applicable country wiring codes.
15
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4 Dielectric Strength Testing
For dielectric strength testing in the field, users must remove the metal jumper located on terminal
2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression
circuitry to chassis ground, and must be removed in order to avoid damage to protection circuits.
Figure 4 shows the proper dielectric strength test connections and should be followed to avoid
damage to the device.
Surge
Ground
Chassis
Ground
Figure 4: Dielectric Strength (HIPOT) Testing
16
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.5 Failsafe Alarm Relay Wiring and Specifications
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the M969
series switches. The contacts are energized upon power up of the unit and remain energized until
a critical error occurs. The proper relay connections are shown in Figure 5 below. One common
application for this output is to signal an alarm if a power failure or removal of control power occurs.
Normal Contact state without power being applied to unit
1. Normally closed
2. Common
3. Normally open
Figure 5: Failsafe Alarm Relay Wiring
17
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.6 Console Port Wiring
A RS232 console port for configuration and management of the device is shown in
Figure 6. This port is intended to be a temporary connection during initial configuration or
troubleshooting and allows for direct access to the serial-based management console. The
connection is made using the DB9-Female to 8-Position-Male-M12 console cable shown in Figure
7. Console connection settings are: 57600 baud, no parity bits, 8 data bits, and 1 stop bit.
Figure 6: Console port
Figure 7: RS969 Console cable
For user reference, the console cable pin-out is show in Table 5.
RuggedCom RS232 over M12 pin-out specification
Signal Name (PC is DTE)
RxD – Receive data (to DTE)
TxD – Transmit data (from DTE)
Signal GND
DB9- Female
M12- Male
2
3
5
2
3
5
Table 2: RS232 over M12 console cable pin-out
After initial configuration, the RuggedSwitch device can be configured via a number of new
mechanisms such as Telnet, and the built-in web server. Consult the RuggedSwitch ROS User
Guide for further details.
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.
18
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
2.7 Fast Ethernet Ports – Signal Description
The RS969 series switches have several 10/100BaseTX ports that allow connection to standard
CAT-5 UTP cable with industrial RJ45 male connectors or industrial D-coded M12 male
connectors. The RJ45/M12 receptacles are directly connected to the chassis ground on the M969
and can accept shielded CAT-5 cables. If shielded cables are used, care must be taken to ensure
the shielded cables do not form a ground loop via the shield wire and the RJ45/M12 receptacles at
either end. Figure 2.6.1 shows the pin configuration.
Pin
1
Signal
+Rx
2
-Rx
+Tx
3
4
No Connection
No Connection
-Tx
5
6
7
No Connection
No Connection
Case Shield (Chassis Ground)
8
Figure 2.6.1 RJ45 Port and M12 Port Pins
NOTE: RuggedCom does not recommend the use of CAT-5 cabling of any length for critical real-
time substation automation applications. However, transient suppression circuitry is present on all
copper ports to protect against damage from electrical transients and to ensure IEC 61850-3 and
IEEE 1613 Class 1 conformance. This means that during the transient event communications
errors or interruptions may occur but recovery is automatic.
RuggedCom also does not recommended to use these ports to interface to field devices across
distances which could produce high levels of ground potential rise, (i.e. greater than 2500V) during
line to ground fault conditions.
19
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Technical Specifications
3.1 Operating Environment
Parameter
Ambient Operating Temperature
Range
-40 to 85°C
Comments
Ambient Temperature as
measured from a 30 cm radius
surrounding the center of the
M969 enclosure.
Ambient Relative Humidity
Ambient Storage Temperature
IP Rating
5% to 95%
-40 to 85°C
Non-condensing
IP67
Operating Altitude
0 to 15240m (0 to 50000 ft)
Over temperature range of -40
to 85°C
3.2 Power Supply Specifications
Minimum
Input
Maximum
Input
Fuse
Rating
Maximum Power
Isolation
Power Supply Type
Consumption
12 – 24 VDC
24 VDC
48 VDC
HI (125/250 VDC) 1
HI (110/230 VAC) 1
10 VDC
18 VDC
36 VDC
88 VDC
85 VAC
36 VDC
36 VDC
72VDC
300 VDC
265 VAC
3.15A (T)
3.15A (T)
3.15A (T)
1.5 kV DC
1.5 kV DC
1.5 kV DC
10W
4 kV AC 5.5
kV DC
3.15A (T)
NOTES:
1. This is the same power supply for both AC and DC.
2. (T) denotes time-delay fuse
3. For continued protection against risk of fire, replace only with same type and rating of fuse.
3.3 Failsafe Relay Specifications
Parameter
Value
Max Switching Voltage
Rated Switching Current
30VAC, 80VDC
0.3A @ 30VAC
1A @ 30VDC, 0.3A @ 80VDC
NOTES:
1. Resistive Load.
2. For Class-2 circuits only.
20
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Isolation
Comments
1500 Vrms
Dielectric test voltage (1 minute) between coil & contacts
3.4 Twisted Pair Data Port Specifications
Data Port
Media
Distance
Connector Type
10/100 Mbps
Cat 5 UTP or STP
100m
RJ45 or M12
3.5 Fiber Optical Port Specifications
For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical
communications. The following table details fiber optic specifications based on the order code / transceiver selected at
time of ordering.
Tx Pwr
(dBm) 3
(Min/Max)
Rx
Rx
Typical
Distance1
(km)
Power
Budget
(dB)
Order
Code
Mode /
Connector
Cable
Type2
Tx λ
(nm)
Sensitivity
Saturation
(dBm) 3
(dBm) 3
2LCMM
2LC10
2LC25
MM / LC
SM / LC
SM / LC
850
1310
1310
-9.5 / -4
-9.5 / -3
-5 / 0
-20
-22
-22
0
-3
-3
0.5
10
25
13
18.5
19.5
50µ/125
9µ/125
9µ/125
NOTES:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and
splices. Please consult RuggedCom sales associates when determining maximum segment distances.
2. All cabling is duplex type unless otherwise specified.
3. All optical power numbers are listed as dBm averages.
21
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6 IEC 61850-3 Type Tests
Severity
Levels
4
Test
Description
Enclosure Contact
Test Levels
+/- 8kV
+/- 15kV
20 V/m
IEC 61000-4-2
IEC 61000-4-3
ESD
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
A.C. Power ports
Earth ground ports
4
x
x
4
4
4
Radiated RFI
+/- 4kV @ 2.5kHz
+/- 4kV
Burst (Fast
Transient)
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
+/- 4kV
+/- 4kV
+/- 4kV line-to-earth, +/- 2kV line-to-
Signal ports
4
3
4
line
+/- 2kV line-to-earth, +/- 1kV line-to-
Surge
D.C. Power ports
A.C. Power ports
line
+/- 4kV line-to-earth, +/- 2kV line-to-
line
Signal ports
D.C Power ports
A.C. Power ports
Earth ground ports
Enclosure ports
10V
10V
10V
10V
3
3
3
3
N/A
Induced
(Conducted) RFI
IEC 61000-4-8
IEC 61000-4-29
Magnetic Field
40 A/m continuous, 1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for
0.05s
30% for 1 period, 60% for 50 periods
100% for 5 periods, 100% for 50
periods 2
2.5kV common, 1kV differential mode
@ 1MHz
2.5kV common, 1kV differential mode
@ 1MHz
2.5kV common, 1kV differential mode
@ 1MHz
D.C. Power ports
N/A
N/A
N/A
Voltage Dips &
Interrupts
A.C. Power ports
IEC 61000-4-11
IEC 61000-4-12
Signal ports
3
3
3
Damped
Oscillatory
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
4
4
Mains Frequency
Voltage
IEC 61000-4-16
IEC 61000-4-17
Ripple on D.C.
Power Supply
D.C. Power ports
10%
3
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
2kV AC (Fail-Safe Relay output)
N/A
N/A
N/A
N/A
N/A
N/A
IEC 60255-5
IEC 60255-5
Dielectric Strength
H.V. Impulse
2kV AC
2kV AC
5kV (Fail-Safe Relay output)
5kV
5kV
22
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3.7 IEEE 1613 Type Tests
IEEE Test IEEE 1613
Description
Test Levels
Clause
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
+/- 8kV
+/- 15kV
35 V/m
+/- 4kV @ 2.5kHz
C37.90.3
C37.90.2
9
ESD
8
Radiated RFI
D.C. Power ports
A.C. Power ports
Earth ground ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
+/- 4kV
+/- 4kV
C37.90.1
7
Fast Transient
+/- 4kV
2.5kV common mode @ 1MHz
2.5kV common & differential mode @ 1MHz
2.5kV common & differential mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
C37.90.1
C37.90
7
6
6
Oscillatory
H.V. Impulse
D.C. Power ports
A.C. Power ports
Signal ports
5 kV
2kV AC(Failsafe Relay)
2kV AC
C37.90
Dielectric Strength
D.C. Power ports
A.C. Power ports
2kV AC
NOTES:
•
If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur but
recovery is automatic).
•
If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will occur).
3.8 IEC Environmental Type Tests
Severity
Levels
Test
Description
Cold Temperature
Test Levels
-40 deg. C, 16 Hours
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
Test Ad
Test Bd
Test Db
Tests Fc
N/A
N/A
Dry Heat
+85 deg. C, 16 Hours
Humidity (Damp Heat,
Cyclic)
95% (non-condensing), 55°C, 6 cycles
2g @ (10-150) Hz
N/A
Vibration
Class 2
IEC 60255-21-2
IEC 60529 (IPx6)
IEC 60529 (IPx7)
Shock
Ingress Protection
Ingress Protection
Tests Ea
Water Jet
Water Submersion
30g @ 11 ms
100l/m @ 2.5m as per 14.2.6
30 min @ 1m as per 14.2.7
Class 2
N/A
N/A
IEC 60529 (IP6x)
Ingress Protection
Dust Talcum
2kg/m3 for 8h as per 13.4
Cat. 1&2
23
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3.9 Mechanical Specifications
24
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Parameter
Value
Comments
Dimensions
7,75 x 7,0 x 4,28 inches
(196,85) x (177,8) x (108,7) mm
Die-cast Aluminum
(Length x Width x Depth)
Enclosure
25
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3.10Agency Approvals
Agency
Standards
Comments
CSA
CSA C22.2 No. 60950, UL 60950
Approved
CE
EN 60950, EN 61000-6-2
Approved
Approved
Approved
Approved
Approved
FCC
FCC Part 15, Class A
CISPR
FDA/CDRH
IEC/EN
EN55022, Class A
21 CFR Chapter 1, Subchapter J
EN60825-1:1994 + A11:1996 + A2:2001
26
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Accessories
4.1 POWER (1/unit)
M23 Power Mating Connector
Description: M23 5pin female connector, 600V, IP68 rated,
RuggedCom P/N 30-50-0012
Cable specs: 3/18AWG, jacket OD range 0.20" - 0.48"
MINI Power Mating Cordset
Description: MINI-Change 4pin female connector; 4/16AWG, rubber
jacket cable, 600V, 3 meters
RuggedCom P/N 43-10-0031
4.2 CONSOLE (1/unit)
M12 Console Port Mating Cable
Description: M12 8pin A-code male to DB9 female; unshielded, PUR
jacket cable, 30V/4A, 3m
RuggedCom P/N 43-10-0023
Cable specs: M12 8pin A-code male to free end, 3m
27
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
M12 Console Port Mating Connector
Description: M12-straight plug, 8 pole, A-coded, IP67 rated
RuggedCom P/N 30-50-0018
4.3 FAILSAFE (1/unit)
M12 FailSafe Port Mating Cable
Description: M12 4pole A-coded; unshielded, PUR Jacket cable, 3m
RuggedCom P/N 43-10-0024
M12 FailSafe Port Mating Connector
Description: M12-straight plug, 4 pole, A-coded, IP67 rated
RuggedCom P/N 30-50-0017
28
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4 ETHERNET (8/unit)
M12 D-code Ethernet Port Mating Cable
Description: M12 D-code to RJ45; patch cable, 3meters
RuggedCom P/N 43-10-0033
Cable specs: M12 dcode male 4PIN, CAT5e, 3m
M12 D-code Ethernet Port Mating Connector
Description: M12-straight plug, 4 pole, D-coded, IP67 rated
RuggedCom P/N 30-50-0015
IP67 RJ45 Ethernet Port Mating Cable
Description: IP67 RJ45 plug to RJ45; Category 5e shielded patch cable,
3.1m
RuggedCom P/N 43-10-0029
29
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
IP67 RJ45 Ethernet Port Mating connector
Description: IP67 RJ45 plug, field attachable
4.5 LC FIBER OPTIC (2/unit)
LC Port Mating Connector
Description: IP67 Multimode LC plug
RuggedCom P/N 30-50-0010
Description: IP67 Singlemode LC plug
RuggedCom P/N 30-50-0023
LC Port Mating Connector
Description: Multimode IP67 LC plug to LC connector, 3m
RuggedCom P/N 43-10-0044
Description: Singlemode IP67 LC plug to LC connector, 3m
RuggedCom P/N 43-10-0043
30
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Warranty
Five (5) years from date of purchase, return to factory. For warranty details, visit
www.ruggedcom.com or contact your customer service representative.
Should this product require warranty or service contact the factory at:
RuggedCom Inc.
30 Whitmore Road,
Woodbridge, Ontario
Canada L4L 7Z4
Tel: (905) 856-5288
Fax: (905) 856-1995
Toll Free: (888) 264-0006