RuggedCom Switch RS969 User Guide

RuggedSwitchRS969  
Installation Guide  
RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4  
Tel: 905-856-5288 I Fax: 905-856-1995 I Toll Free: 1-888-264-0006  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
1
2
Product Overview.....................................................................................................................4  
1.1 RS969 Family Ports/Connectors Description.................................................................. 5  
Installation................................................................................................................................7  
2.1  
2.2  
2.3  
DIN Rail Mounting........................................................................................................... 7  
Ingress Protection IP67 .................................................................................................. 8  
Power Supply Wiring and Grounding.............................................................................. 9  
2.3.1 Power Supply Input Connectors Description .............................................................. 9  
2.3.2 Single AC Power Supply Wiring Examples............................................................... 12  
2.3.3 Single DC Power Supply Wiring Examples .............................................................. 13  
2.3.4 Dual Power Supplies – DC and AC Inputs ............................................................... 14  
2.4  
Dielectric Strength (HIPOT) Testing ............................................................................. 16  
Failsafe Alarm Relay Wiring and Specifications............................................................ 17  
Console Port Wiring...................................................................................................... 18  
Fast Ethernet Ports – Signal Description...................................................................... 19  
2.5  
2.6  
2.7  
3
Technical Specifications.........................................................................................................20  
3.1  
Operating Environment................................................................................................. 20  
Power Supply Specifications......................................................................................... 20  
Failsafe Relay Specifications........................................................................................ 20  
Twisted Pair Data Port Specifications........................................................................... 21  
Fiber Optical Port Specifications................................................................................... 21  
IEC 61850-3 Type Tests............................................................................................... 22  
IEEE 1613 Type Tests.................................................................................................. 23  
IEC Environmental Type Tests ..................................................................................... 23  
Mechanical Specifications ............................................................................................ 24  
3.2  
3.3  
3.4  
3.5  
3.6  
3.7  
3.8  
3.9  
3.10 Agency Approvals......................................................................................................... 26  
Accessories............................................................................................................................27  
4.1 POWER (1/unit)................................................................................................................... 27  
4.2 CONSOLE (1/unit)............................................................................................................... 27  
4.3 FAILSAFE (1/unit)................................................................................................................ 28  
4.4 ETHERNET (8/unit) ............................................................................................................. 29  
4.5 LC FIBER OPTIC (2/unit)..................................................................................................... 30  
Warranty.................................................................................................................................31  
4
5
3
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Product Overview  
The RuggedSwitch™ RS969 is an industrially hardened, fully managed Ethernet switch providing  
dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports in an IP65/IP67  
rated package for protection against low pressure jets of water (IP65) or temporary immersion in  
water (IP67). Designed to operate reliably in harsh industrial environments the RS969 provides a  
high level of immunity to electromagnetic interference and heavy electrical surges typical of  
environments found in electric utility substations, factory floors or in curb side traffic control  
cabinets. An operating temperature range of -40°C to +85°C coupled with hazardous location  
certification and IP65/IP67 rated waterproof packaging allows the RS969 to be placed in virtually  
any location. The embedded Rugged Operating System (ROS™) provides advanced networking  
features such as Enhanced Rapid Spanning Tree (eRSTP™), Port Rate Limiting and a full array  
of intelligent functionality for high network availability and manageability.  
Ethernet Ports  
Universal Power Supply Options  
Fully integrated power supply  
2 - Fiber Optical Gigabit Ethernet Ports  
(1000BaseX) with:.IP65/IP67 Rated fiber  
optical connectors (type LC)  
Universal high-voltage range: 88-300VDC or  
85-264VACPopular low-voltage DC ranges:  
12, 24, 48 VDC  
8 - Fast Ethernet Ports (10/100BaseTX) with  
IP65/IP67 Rated M12 D-code connectors or  
IP65/IP67 Rated shrouded RJ45 style  
connectors  
Dual redundant, parallel load-sharing power  
supplies (option)  
Can be powered from different sources for  
ultimate redundancy  
Full compliance with IEEE: 802.3, 802.3u  
and 802.3z  
Available with M12 or M23 style connectors  
CSA/UL 60950 safety approved to +85°C  
Non-blocking, store and forward switching  
Full duplex operation and flow control (IEEE  
802.3x)  
Simple Plug and Play Operation  
Automatic learning of up to 8192  
MAC addresses  
RuggedRatedfor Reliability in Harsh  
Environments  
Auto-negotiation on all 10/100BaseTX ports  
Auto-MDI/MDIX (crossover) on all  
10/100BaseTX ports  
IP67 Rated for protection against immersion  
in water  
IP66 Rated for protection against high  
pressure jets of water  
LED indicators for link and activity  
Meets IEEE 1613 (electric utility substations)  
Exceeds IEC 61850-3  
(electric utility substations)  
ROS™ Advanced Network Management  
Enhanced Rapid Spanning Tree (eRSTPTM)  
Quality of Service (802.1p) for real-time  
traffic  
Exceeds IEEE 61800-3  
(variable speed drive systems)  
Exceeds IEC 61000-6-2  
(generic industrial environment)  
Exceeds NEMA TS-2  
(traffic control equipment)  
Port rate limiting: 128kbps to 8Mbps  
VLAN (802.1q) with double tagging  
IGMP Snooping for multicast filtering  
Port configuration, status, statistics,  
mirroring, security  
-40 to +85°C operating temperature (no fans)  
Conformal coated circuit boards (optional)  
Loss of link management on fiber ports  
Web-based, Telnet, CLI management  
interfaces  
SNMP v2 and RMON  
Rich set of diagnostics with logging and  
alarms  
4
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1 RS969 Family Ports/Connectors Description  
Figure 1.1.1 RS969–M12 with Mini-Change Power Connector  
5
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 1.1.2 RS969–RJ45 with M23 Power Connector  
ITEM  
LINK LED (Yellow)  
Activity  
Solid  
Blinking  
Solid  
Solid  
Solid  
Comments  
Link Established  
Tx/Rx Activity  
Power 1 LED  
Power 2 LED  
Alarm LED (Red)  
Power Supply 1 On  
Power Supply 2 On  
Alarm condition exists  
6
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Installation  
2.1 DIN Rail Mounting  
An optional DIN rail mounting bracket is available for the RS969. Figure 2.1.1 details mounting  
instructions for the standard 1” DIN Rail.  
Optional  
DIN Rail  
DIN  
Mounting  
Rail  
Bracket  
Release  
Latch  
Release Direction  
Figure 2.1.1 RS969 Family DIN Rail Mounting  
7
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Ingress Protection IP67  
IEC International Standard 60529 (Edition 2.1: 2001-02) is a "classification of degrees of protection  
provided by enclosures as a system for specifying the enclosures of electrical equipment on the  
basis of the degree of protection provided by the enclosure." These ratings are determined by  
specific tests  
The IP number is composed of two numbers, the first referring to the protection against solid  
objects and the second against liquids. The higher the IP number, the better the protection. The  
chart below defines levels of IP ratings.  
1st  
IP#  
Degree of protection against access to  
hazardous parts & ingress of solid objects  
2nd  
IP#  
Degree of protection against the  
ingress of water  
0
1
No protection  
0
1
No protection  
Protected against solid foreign objects of 50 mm Ø  
and >  
Protected against vertically falling water drops  
Protected against solid foreign objects of 12.5 mm Ø  
and >  
Protected against vertically falling water drops  
when enclosure titled up 15°  
2
3
4
2
3
4
Protected against solid foreign objects of 2.5 mm Ø  
and >  
Protected against spraying water  
Protected against splashing water  
Protected against solid foreign objects of 1.0 mm Ø  
and >  
5
6
Dust protected  
Dust tight  
5
6
Protected against jet-water  
Protected against strong jet-water  
Protected against the effects of temporary  
submersion in water  
7
8
Protected against the effects of permanent  
submersion in water  
The RuggedCom M969 Industrial Ethernet Switch is manufactured and tested to IP67 standards.  
With an IP67 rating a product will be "dust tight" and remain completely sealed when immersed in  
water to a depth of 1 meter for 1 hour. (IEC 60529)  
These caps completely seals off unused ports on the IP67 Industrial  
Ethernet Switch. It has an IP67 rated seal that keeps out all  
contaminants like dirt, oil, and water.  
8
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Power Supply Wiring and Grounding  
2.3.1 Power Supply Input Connectors Description  
Mini power supply connector  
M23 power supply connector  
Figure 2.2.1.1 RS969 Family Power Supply Inputs  
S u rge  
G ro u n d  
C h assis  
G ro u n d  
Figure 2.2.1.2 RS969 Family Surge Ground / Chassis Ground Connection  
9
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The RS969 family has 2 different power supply input connectors---Mini A-coded male connector or  
M23 A-code male connector shown in Figure 2.2.1.1. The Mini power connector only has 4  
terminals, so only one power supply source is allowed to connect to the RS969 with Mini power  
connector; The M23 power connector has 5 terminal pins which means 2 power supply sources are  
allowed to power the RS969 with M23 power connector.  
The RS969 family supports dual redundant power supplies – “Power Supply 1 (PS1)” and “Power  
Supply 2 (PS2)”. The connections for PS1, PS2 are shown in Table1 and 2.  
Refer to  
Table 1 and 2 for a description of each terminal and sections 2.3.2 through 2.3.4 for wiring  
examples.  
Terminal #  
Description  
Usage  
PS1 Live / + is connected to the positive (+) terminal if the  
PS1 Live / + power source is DC or to the (Live) terminal if the power  
source is AC.  
1
PS1 Neutral / - is connected to the negative (-) terminal if  
PS1 Neutral / - the power source is DC or to the (Neutral) terminal if the  
power source is AC.  
2
3
Chassis Ground is connected to the Safety Ground  
terminal for AC inputs or the equipment ground bus for DC  
inputs. This terminal 3 is connected to chassis ground  
internally in the RS969 family. There is also an additional  
chassis ground screw and the chassis ground connects to  
Chassis  
Ground  
both power supply surge grounds via a removable jumper  
shown in Figure 2.2.1.2 .  
PS2 Live / + is connected to the positive (+) terminal if the  
power source is DC or to the (Live) terminal if the power  
source is AC.  
4
5
PS2 Live / +  
PS2 Neutral / - is connected to the negative (-) terminal if  
PS2 Neutral / - the power source is DC or to the (Neutral) terminal if the  
power source is AC.  
Table 1: RS969 Power terminal block connection description for M23 A-code male connector  
10  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terminal #  
Description  
Usage  
PS1 Live / + is connected to the positive (+) terminal if the  
PS1 Live / + power source is DC or to the (Live) terminal if the power  
source is AC.  
1
Chassis Ground is connected to the Safety Ground  
terminal for AC inputs or the equipment ground bus for DC  
inputs. This terminal 3 is connected to chassis ground  
internally in the RS969 family. There is also an additional  
chassis ground screw and the chassis ground connects to  
2
3
Chassis  
Ground  
both power supply surge grounds via a removable jumper  
shown in Figure 2.2.1.2 .  
PS1 Neutral / - is connected to the negative (-) terminal if  
PS1 Neutral / - the power source is DC or to the (Neutral) terminal if the  
power source is AC.  
4
Table 2: RS969 Power terminal block connection description for Mini A-coded male connector  
NOTES:  
1. Equipment must be installed according to the applicable country wiring codes.  
2. Surge Ground must be disconnected from the Chassis Ground during HIPOT (dielectric  
strength) testing.  
3. All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases  
where users require the inputs to be isolated from ground, remove the ground braid  
between Surge and Chassis Ground. All line-to-ground transient protection circuitry will be  
disabled.  
11  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.2 Single AC Power Supply Wiring Examples  
Figure 1: AC Power supply wiring examples  
NOTES:  
1. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be  
installed within 3m of unit.  
2. Equipment must be installed according to the applicable country wiring codes.  
3. When equipped with two HI voltage power supplies, independent AC sources can be used  
to power the product for greater redundancy.  
12  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.3 Single DC Power Supply Wiring Examples  
Figure 2: DC Power supply wiring examples  
NOTES:  
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be  
installed within 3m of unit.  
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.  
3. For dual DC power supplies, Separate circuit breakers must be installed and  
separately identified.  
4. Equipment must be installed according to the applicable country wiring codes.  
13  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.4 Dual Power Supplies – DC and AC Inputs  
14  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 3: DC And AC power supply wiring examples  
NOTES:  
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be  
installed within 3m of unit.  
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.  
3. Separate circuit breakers must be installed and separately identified.  
4. Equipment must be installed according to the applicable country wiring codes.  
15  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Dielectric Strength Testing  
For dielectric strength testing in the field, users must remove the metal jumper located on terminal  
2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression  
circuitry to chassis ground, and must be removed in order to avoid damage to protection circuits.  
Figure 4 shows the proper dielectric strength test connections and should be followed to avoid  
damage to the device.  
Surge  
Ground  
Chassis  
Ground  
Figure 4: Dielectric Strength (HIPOT) Testing  
16  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5 Failsafe Alarm Relay Wiring and Specifications  
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the M969  
series switches. The contacts are energized upon power up of the unit and remain energized until  
a critical error occurs. The proper relay connections are shown in Figure 5 below. One common  
application for this output is to signal an alarm if a power failure or removal of control power occurs.  
Normal Contact state without power being applied to unit  
1. Normally closed  
2. Common  
3. Normally open  
Figure 5: Failsafe Alarm Relay Wiring  
17  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.6 Console Port Wiring  
A RS232 console port for configuration and management of the device is shown in  
Figure 6. This port is intended to be a temporary connection during initial configuration or  
troubleshooting and allows for direct access to the serial-based management console. The  
connection is made using the DB9-Female to 8-Position-Male-M12 console cable shown in Figure  
7. Console connection settings are: 57600 baud, no parity bits, 8 data bits, and 1 stop bit.  
Figure 6: Console port  
Figure 7: RS969 Console cable  
For user reference, the console cable pin-out is show in Table 5.  
RuggedCom RS232 over M12 pin-out specification  
Signal Name (PC is DTE)  
RxD – Receive data (to DTE)  
TxD – Transmit data (from DTE)  
Signal GND  
DB9- Female  
M12- Male  
2
3
5
2
3
5
Table 2: RS232 over M12 console cable pin-out  
After initial configuration, the RuggedSwitch device can be configured via a number of new  
mechanisms such as Telnet, and the built-in web server. Consult the RuggedSwitch ROS User  
Guide for further details.  
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m  
(6.5 ft) in length.  
18  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.7 Fast Ethernet Ports – Signal Description  
The RS969 series switches have several 10/100BaseTX ports that allow connection to standard  
CAT-5 UTP cable with industrial RJ45 male connectors or industrial D-coded M12 male  
connectors. The RJ45/M12 receptacles are directly connected to the chassis ground on the M969  
and can accept shielded CAT-5 cables. If shielded cables are used, care must be taken to ensure  
the shielded cables do not form a ground loop via the shield wire and the RJ45/M12 receptacles at  
either end. Figure 2.6.1 shows the pin configuration.  
Pin  
1
Signal  
+Rx  
2
-Rx  
+Tx  
3
4
No Connection  
No Connection  
-Tx  
5
6
7
No Connection  
No Connection  
Case Shield (Chassis Ground)  
8
Figure 2.6.1 RJ45 Port and M12 Port Pins  
NOTE: RuggedCom does not recommend the use of CAT-5 cabling of any length for critical real-  
time substation automation applications. However, transient suppression circuitry is present on all  
copper ports to protect against damage from electrical transients and to ensure IEC 61850-3 and  
IEEE 1613 Class 1 conformance. This means that during the transient event communications  
errors or interruptions may occur but recovery is automatic.  
RuggedCom also does not recommended to use these ports to interface to field devices across  
distances which could produce high levels of ground potential rise, (i.e. greater than 2500V) during  
line to ground fault conditions.  
19  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Technical Specifications  
3.1 Operating Environment  
Parameter  
Ambient Operating Temperature  
Range  
-40 to 85°C  
Comments  
Ambient Temperature as  
measured from a 30 cm radius  
surrounding the center of the  
M969 enclosure.  
Ambient Relative Humidity  
Ambient Storage Temperature  
IP Rating  
5% to 95%  
-40 to 85°C  
Non-condensing  
IP67  
Operating Altitude  
0 to 15240m (0 to 50000 ft)  
Over temperature range of -40  
to 85°C  
3.2 Power Supply Specifications  
Minimum  
Input  
Maximum  
Input  
Fuse  
Rating  
Maximum Power  
Isolation  
Power Supply Type  
Consumption  
12 – 24 VDC  
24 VDC  
48 VDC  
HI (125/250 VDC) 1  
HI (110/230 VAC) 1  
10 VDC  
18 VDC  
36 VDC  
88 VDC  
85 VAC  
36 VDC  
36 VDC  
72VDC  
300 VDC  
265 VAC  
3.15A (T)  
3.15A (T)  
3.15A (T)  
1.5 kV DC  
1.5 kV DC  
1.5 kV DC  
10W  
4 kV AC 5.5  
kV DC  
3.15A (T)  
NOTES:  
1. This is the same power supply for both AC and DC.  
2. (T) denotes time-delay fuse  
3. For continued protection against risk of fire, replace only with same type and rating of fuse.  
3.3 Failsafe Relay Specifications  
Parameter  
Value  
Max Switching Voltage  
Rated Switching Current  
30VAC, 80VDC  
0.3A @ 30VAC  
1A @ 30VDC, 0.3A @ 80VDC  
NOTES:  
1. Resistive Load.  
2. For Class-2 circuits only.  
20  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolation  
Comments  
1500 Vrms  
Dielectric test voltage (1 minute) between coil & contacts  
3.4 Twisted Pair Data Port Specifications  
Data Port  
Media  
Distance  
Connector Type  
10/100 Mbps  
Cat 5 UTP or STP  
100m  
RJ45 or M12  
3.5 Fiber Optical Port Specifications  
For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical  
communications. The following table details fiber optic specifications based on the order code / transceiver selected at  
time of ordering.  
Tx Pwr  
(dBm) 3  
(Min/Max)  
Rx  
Rx  
Typical  
Distance1  
(km)  
Power  
Budget  
(dB)  
Order  
Code  
Mode /  
Connector  
Cable  
Type2  
Tx λ  
(nm)  
Sensitivity  
Saturation  
(dBm) 3  
(dBm) 3  
2LCMM  
2LC10  
2LC25  
MM / LC  
SM / LC  
SM / LC  
850  
1310  
1310  
-9.5 / -4  
-9.5 / -3  
-5 / 0  
-20  
-22  
-22  
0
-3  
-3  
0.5  
10  
25  
13  
18.5  
19.5  
50µ/125  
9µ/125  
9µ/125  
NOTES:  
1. Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and  
splices. Please consult RuggedCom sales associates when determining maximum segment distances.  
2. All cabling is duplex type unless otherwise specified.  
3. All optical power numbers are listed as dBm averages.  
21  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6 IEC 61850-3 Type Tests  
Severity  
Levels  
4
Test  
Description  
Enclosure Contact  
Test Levels  
+/- 8kV  
+/- 15kV  
20 V/m  
IEC 61000-4-2  
IEC 61000-4-3  
ESD  
Enclosure Air  
Enclosure ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Earth ground ports  
4
x
x
4
4
4
Radiated RFI  
+/- 4kV @ 2.5kHz  
+/- 4kV  
Burst (Fast  
Transient)  
IEC 61000-4-4  
IEC 61000-4-5  
IEC 61000-4-6  
+/- 4kV  
+/- 4kV  
+/- 4kV line-to-earth, +/- 2kV line-to-  
Signal ports  
4
3
4
line  
+/- 2kV line-to-earth, +/- 1kV line-to-  
Surge  
D.C. Power ports  
A.C. Power ports  
line  
+/- 4kV line-to-earth, +/- 2kV line-to-  
line  
Signal ports  
D.C Power ports  
A.C. Power ports  
Earth ground ports  
Enclosure ports  
10V  
10V  
10V  
10V  
3
3
3
3
N/A  
Induced  
(Conducted) RFI  
IEC 61000-4-8  
IEC 61000-4-29  
Magnetic Field  
40 A/m continuous, 1000 A/m for 1 s  
30% for 0.1s, 60% for 0.1s, 100% for  
0.05s  
30% for 1 period, 60% for 50 periods  
100% for 5 periods, 100% for 50  
periods 2  
2.5kV common, 1kV differential mode  
@ 1MHz  
2.5kV common, 1kV differential mode  
@ 1MHz  
2.5kV common, 1kV differential mode  
@ 1MHz  
D.C. Power ports  
N/A  
N/A  
N/A  
Voltage Dips &  
Interrupts  
A.C. Power ports  
IEC 61000-4-11  
IEC 61000-4-12  
Signal ports  
3
3
3
Damped  
Oscillatory  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
30V Continuous, 300V for 1s  
30V Continuous, 300V for 1s  
4
4
Mains Frequency  
Voltage  
IEC 61000-4-16  
IEC 61000-4-17  
Ripple on D.C.  
Power Supply  
D.C. Power ports  
10%  
3
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
2kV AC (Fail-Safe Relay output)  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
IEC 60255-5  
IEC 60255-5  
Dielectric Strength  
H.V. Impulse  
2kV AC  
2kV AC  
5kV (Fail-Safe Relay output)  
5kV  
5kV  
22  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.7 IEEE 1613 Type Tests  
IEEE Test IEEE 1613  
Description  
Test Levels  
Clause  
Enclosure Contact  
Enclosure Air  
Enclosure ports  
Signal ports  
+/- 8kV  
+/- 15kV  
35 V/m  
+/- 4kV @ 2.5kHz  
C37.90.3  
C37.90.2  
9
ESD  
8
Radiated RFI  
D.C. Power ports  
A.C. Power ports  
Earth ground ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
+/- 4kV  
+/- 4kV  
C37.90.1  
7
Fast Transient  
+/- 4kV  
2.5kV common mode @ 1MHz  
2.5kV common & differential mode @ 1MHz  
2.5kV common & differential mode @ 1MHz  
5 kV (Failsafe Relay)  
5 kV  
C37.90.1  
C37.90  
7
6
6
Oscillatory  
H.V. Impulse  
D.C. Power ports  
A.C. Power ports  
Signal ports  
5 kV  
2kV AC(Failsafe Relay)  
2kV AC  
C37.90  
Dielectric Strength  
D.C. Power ports  
A.C. Power ports  
2kV AC  
NOTES:  
If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur but  
recovery is automatic).  
If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will occur).  
3.8 IEC Environmental Type Tests  
Severity  
Levels  
Test  
Description  
Cold Temperature  
Test Levels  
-40 deg. C, 16 Hours  
IEC 60068-2-1  
IEC 60068-2-2  
IEC 60068-2-30  
IEC 60255-21-1  
Test Ad  
Test Bd  
Test Db  
Tests Fc  
N/A  
N/A  
Dry Heat  
+85 deg. C, 16 Hours  
Humidity (Damp Heat,  
Cyclic)  
95% (non-condensing), 55°C, 6 cycles  
2g @ (10-150) Hz  
N/A  
Vibration  
Class 2  
IEC 60255-21-2  
IEC 60529 (IPx6)  
IEC 60529 (IPx7)  
Shock  
Ingress Protection  
Ingress Protection  
Tests Ea  
Water Jet  
Water Submersion  
30g @ 11 ms  
100l/m @ 2.5m as per 14.2.6  
30 min @ 1m as per 14.2.7  
Class 2  
N/A  
N/A  
IEC 60529 (IP6x)  
Ingress Protection  
Dust Talcum  
2kg/m3 for 8h as per 13.4  
Cat. 1&2  
23  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.9 Mechanical Specifications  
24  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parameter  
Value  
Comments  
Dimensions  
7,75 x 7,0 x 4,28 inches  
(196,85) x (177,8) x (108,7) mm  
Die-cast Aluminum  
(Length x Width x Depth)  
Enclosure  
25  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.10Agency Approvals  
Agency  
Standards  
Comments  
CSA  
CSA C22.2 No. 60950, UL 60950  
Approved  
CE  
EN 60950, EN 61000-6-2  
Approved  
Approved  
Approved  
Approved  
Approved  
FCC  
FCC Part 15, Class A  
CISPR  
FDA/CDRH  
IEC/EN  
EN55022, Class A  
21 CFR Chapter 1, Subchapter J  
EN60825-1:1994 + A11:1996 + A2:2001  
26  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Accessories  
4.1 POWER (1/unit)  
M23 Power Mating Connector  
Description: M23 5pin female connector, 600V, IP68 rated,  
RuggedCom P/N 30-50-0012  
Cable specs: 3/18AWG, jacket OD range 0.20" - 0.48"  
MINI Power Mating Cordset  
Description: MINI-Change 4pin female connector; 4/16AWG, rubber  
jacket cable, 600V, 3 meters  
RuggedCom P/N 43-10-0031  
4.2 CONSOLE (1/unit)  
M12 Console Port Mating Cable  
Description: M12 8pin A-code male to DB9 female; unshielded, PUR  
jacket cable, 30V/4A, 3m  
RuggedCom P/N 43-10-0023  
Cable specs: M12 8pin A-code male to free end, 3m  
27  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M12 Console Port Mating Connector  
Description: M12-straight plug, 8 pole, A-coded, IP67 rated  
RuggedCom P/N 30-50-0018  
4.3 FAILSAFE (1/unit)  
M12 FailSafe Port Mating Cable  
Description: M12 4pole A-coded; unshielded, PUR Jacket cable, 3m  
RuggedCom P/N 43-10-0024  
M12 FailSafe Port Mating Connector  
Description: M12-straight plug, 4 pole, A-coded, IP67 rated  
RuggedCom P/N 30-50-0017  
28  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4 ETHERNET (8/unit)  
M12 D-code Ethernet Port Mating Cable  
Description: M12 D-code to RJ45; patch cable, 3meters  
RuggedCom P/N 43-10-0033  
Cable specs: M12 dcode male 4PIN, CAT5e, 3m  
M12 D-code Ethernet Port Mating Connector  
Description: M12-straight plug, 4 pole, D-coded, IP67 rated  
RuggedCom P/N 30-50-0015  
IP67 RJ45 Ethernet Port Mating Cable  
Description: IP67 RJ45 plug to RJ45; Category 5e shielded patch cable,  
3.1m  
RuggedCom P/N 43-10-0029  
29  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP67 RJ45 Ethernet Port Mating connector  
Description: IP67 RJ45 plug, field attachable  
4.5 LC FIBER OPTIC (2/unit)  
LC Port Mating Connector  
Description: IP67 Multimode LC plug  
RuggedCom P/N 30-50-0010  
Description: IP67 Singlemode LC plug  
RuggedCom P/N 30-50-0023  
LC Port Mating Connector  
Description: Multimode IP67 LC plug to LC connector, 3m  
RuggedCom P/N 43-10-0044  
Description: Singlemode IP67 LC plug to LC connector, 3m  
RuggedCom P/N 43-10-0043  
30  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Warranty  
Five (5) years from date of purchase, return to factory. For warranty details, visit  
www.ruggedcom.com or contact your customer service representative.  
Should this product require warranty or service contact the factory at:  
RuggedCom Inc.  
30 Whitmore Road,  
Woodbridge, Ontario  
Canada L4L 7Z4  
Tel: (905) 856-5288  
Fax: (905) 856-1995  
Toll Free: (888) 264-0006  
31  
2008 RuggedCom Inc. All rights reserved  
Rev104  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA Portable CD Player RCD3379 User Guide
RCA Speaker RP 9990 User Guide
Roland Musical Instrument VGA 3 User Guide
Samsung Clothes Dryer DC68 02347B EN User Guide
Samsung Printer 3710 User Guide
Samsung Printer SCX 6x22 User Guide
Scotsman Ice Ice Maker C0330 User Guide
Sears Chainsaw C944414460 User Guide
Sears Cultivator CC 560 User Guide
SECO LARM USA Home Security System VA 1102B WQ User Guide