Installation and Assembly:
20" Column Mount
Model: MIS374A
Max Load Capacity: 80 lb (36.3 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 03-30-07 SHEET #: 124-9053-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation to Solid Concrete Column
WARNING
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the column will safely support the combined load of the equipment and all attached hardware and
components.
Make sure that column plate (A) is level, use it as a
concrete
surface
1
1
template to mark four mounting holes. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Insert anchors (B) in holes flush with
column as shown (right). Place column plate over
anchors and secure with four #14 x 2-1/2" screws
(C). Level, then tighten all fasteners.
B
Drill holes and insert anchors (B).
2
A
B
C
WARNING
• Tighten screws so that column plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
Place plate (A) over anchors (B) and secure with screws (C).
3
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.
B
concrete
column
A
C
CORRECT
INCORRECT
column
plate
concrete
concrete
column
plate
plaster/
drywall
plaster/
drywall
ISSUED: 03-30-07 SHEET #: 124-9053-1
3 of 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation of ST 630 to Column Plate
Note: Model ST 630 is required for assembly.
Tilt assembly of ST 630 is required to complete step 2.
Attach tilt assembly to column plate (A) using two 1/4-20 x 1/2 phillips screws (D), two split washers (F) and two flat
washers(E).
2
TILT
ASSEMBLY
A
E
F
D
Refer to Attaching Adapter Plate to Flat Panel Screen section of ST 630 instruction manual to complete assembly.
ISSUED: 03-30-07 SHEET #: 124-9053-1
4 of 4
©2007, PeerlessIndustries, Inc. Allrightsreserved.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.