Parker Hannifin Handheld Game System VO40 User Manual

VO40 Open-Center  
Directional Control  
Valve  
Catalog HY17-8505/UK  
April 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Contents  
VO40  
Parker Hannifin Corporation  
III  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
VO40  
Conversion factors  
1 kg  
1 N  
= 2.2046 lb  
= 0.22481 lbf  
1 bar  
1 l  
1 l  
1 cm3  
1 m  
1 mm  
= 14.504 psi  
= 0.21997 UK gallon  
= 0.26417 US gallon  
= 0.061024 in3  
= 3.2808 feet  
= 0.03937 in  
9/5 °C + 32 = °F  
Parker Hannifin Corporation  
IV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Introduction  
VO40  
Breadth of Line  
Parker Hannifin is a Fortune 500  
company with sales of $9 billion  
and over 400,000 customers in 43  
countries. Parker is the world’s  
leading supplier of motion control  
components and system solutions  
serving the mobile, industrial  
and aerospace markets.  
Parker is your single source  
for any hydraulic valve require-  
ment. We provide a wide selection  
of open-center and load-sense  
directional control valves for any  
construction, off-highway, or on-  
highway application. Many of our  
open-center valves can be adapted  
and used as closed-center, constant-  
pressure, and constant-pressure  
unloaded valves. Each of these  
technologies offers unique features  
for improved machine performance  
over traditional, open-center control  
valves.  
uptime. The IQAN valve drivers  
offer superior control of propor-  
tional hydraulic functions resulting  
in increased machine productivity.  
Non-programmers find IQAN’s  
programming interface easy to use,  
reducing development time. Fur-  
thermore, excellent diagnostic tools  
and remote modem connection help  
cut field service time.  
When remote control is required,  
Parker provides a broad line of  
pilot controllers that are compact  
and pressure-matched with our  
control valves to provide consistent  
and optimized machine control.  
There are a variety of electric-  
switch handle options available  
for additional function control by  
the operator.  
Parker’s premier IQAN electron-  
ics packages range from simple  
stand-alone controllers to large,  
multiple CAN bus systems with  
color displays. For example, IQAN  
interfaces with new electronic  
diesel engines over the SAE J1939  
CAN bus.  
Total Machine  
Motion Control  
You can turn to us for all your  
mobile motion control solutions.  
We offer stand-alone valves, as well  
as custom-designed manifolds with  
integrated directional control valves.  
Package components are  
designed and tested for  
mobile applications to  
help increase machine  
No matter what type of system you  
choose, Parker solutions provide  
top-notch performance and reli-  
ability. Our systems are optimized  
to reduce complexity, size, cost, and  
fluid leakage. Therefore, working  
with Parker can significantly cut  
your machine-build time.  
Parker Hannifin Corporation  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Introduction  
VO40  
You also benefit from Parker  
Mobile Technology Centers  
(MTCs) that are staffed by specially  
trained distributors who provide  
only the highest levels of customer  
service. These one-stop shops offer  
complete hydraulic systems design  
for mobile applications, as well as  
technology services such as diag-  
nostics, troubleshooting, computer  
design, testing, and integration of  
electronic controls.  
Finally, our thousands of depend-  
able distributors are strategically  
located in your markets. They carry  
inventory to meet specific, local  
market needs, and they ensure that  
products arrive when and where  
they are needed. You can count on  
Parker distributors to minimize  
downtime.  
State-of-the-Art  
Manufacturing  
To locate your nearest distributor  
for the latest information on the  
VO40 Directional Control Valve, or  
our entire mobile valve line-up, visit  
Parker is committed to using lean  
manufacturing to eliminate waste  
while streamlining processes.  
Lean technology helps us meet  
customer request dates quickly  
and cost-effectively. We also rely  
on state-of-the-art equipment and  
technology, such as computer-  
aided machining, to ensure  
product quality.  
Customer Service  
with A Global Reach  
Parker’s worldwide network of field  
sales engineers and Mobile Systems  
Engineers (MSEs) are the best in  
the business. A field sales engineer  
works closely with you, acting as a  
single point of contact to evaluate  
applications and design solutions.  
MSEs support field sales efforts by  
managing difficult design problems  
and complex circuit design.  
We regularly invest in our ISO 9001  
certified manufacturing facilities  
because we are committed to  
meeting all international standards  
for safety and quality. The hydraulic  
valves we manufacture comply with  
relevant ISO, CSA, CE, and AMEX  
standards.  
In addition, Parker hydraulic valves  
and valve manifolds are fully tested  
and certified before being released  
to the customer. You can expect  
Parker hydraulic valves to work the  
first time, every time.  
Parker Hannifin Corporation  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Technical Information  
VO40  
General Description  
The VO40 is an open-center directional control valve  
with the flexibility of sectional construction. Consis-  
tent with this technology, it is simple in its application,  
reliable, easy to troubleshoot, and cost effective. The  
global design reflects the performance and quality ex-  
pected by today’s machine designers. Spools have me-  
tering notches in the three critical areas – open- center,  
parallel path and tank, which optimizes simultaneous  
metering. Contemporary honing technology is used to  
deliver low work port to tank leakage. Additionally, each  
work section has a transition check to ensure that a  
load does not “dip” during simultaneous operation. All  
of these features, plus those listed below, were intend-  
ed to take machine controllability to the next level.  
Operation  
The VO40 incorporates traditional open-center technol-  
ogy. It is usually interfaced with a constant flow pump,  
whose flow is routed directly to tank when the spools  
are in neutral. When one or more spools are selected,  
flow is directed to the actuators. The throttling of that  
flow depends upon the spool position and the design of  
the metering notches. Spool notches can be designed  
to accommodate resistive loads (meter-in) and nega-  
tive loads (meter-out). To accommodate multiple pump  
circuits, split flow and combined flow mid inlets are  
available.  
Benefits  
Enhanced metering – especially during simultaneous  
operation, this is accomplished by having notches in the  
three critical areas of the spool: open center, parallel path  
and tank.  
Improved simultaneous metering – having a transition  
check in each work section ensures that a load does not  
“dip” downward when metering two or more work-sections.  
Repeatability – consistent metering from valve to valve  
is achieved by flycutting all of the critical cast lands. This  
means that the notch position relative to the spool stroke  
is controlled and predictable. The result is consistent  
machine control.  
Reduced operator fatigue – the open-center core is  
a split wing or “Y” core design, which provides for a  
consistent lever force when selecting the spool from  
neutral to both power positions.  
Reduced function drift – low internal leakage  
accomplished thru the use of contemporary honing  
technology. Also, for those functions requiring near zero  
drift, pilot-operated checks are available.  
Small footprint – port accessories are installed vertical  
to the spool, allowing the handle to be positioned closer to  
the valve body.  
Ease of service – the bottom two stud assemblies are  
slotted, enabling a work section to be replaced without  
completely disassembling the valve assembly. This is  
accomplished by loosening the top tie bolt and then lifting  
the section out of the assembly. Downtime is minimized.  
Easy conversion from a left-handed to a right-handed  
section – the work section housing and spool are  
symmetrical, which enables the spool to be inserted in  
either end of the housing.  
Improved spool seal life – the enclosed handle assembly  
protects the spool and spool seal area from contamination  
and the potential corrosion.  
Parker Hannifin Corporation  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Technical Information  
VO40  
Specifications  
Connections  
Pressures  
Inlet Port: 300 bar (4350 PSI)  
Tank Port: 50 bar (725 PSI)  
Work Ports: 300 bar (4350 PSI)  
Standard valves are available in 3/8" BSP (DIN 3852/2), SAE-6  
or SAE-8 (J1926/1).  
Flow Rates  
40 LPM (10.6 GPM)  
(maximum  
Connection Location  
SAE -8  
SAE-6  
BSP  
C\,-19  
C\,-19  
C\,-19  
C\,-19  
C\,-19  
recommended)  
P1, P2  
T1, T2  
P3  
Inlet  
Inlet  
¾-16 UNF >\zn-18 UNF  
¾-16 UNF >\zn-18 UNF  
¾-16 UNF >\zn-18 UNF  
¾-16 UNF >\zn-18 UNF  
¾-16 UNF >\zn-18 UNF  
Internal Pilot  
Pressure  
Required for solenoids –  
contact Parker  
Spool Leakage  
from work port  
to tank  
Max. 6 mL/min @172 bar (2500 PSI)  
Oil temp. 50ºC (122ºF), and viscosity  
40 cSt  
Outlet  
Outlet  
Outlet  
T3  
PB1  
Weights  
Work  
Sections  
Weights are approximate due to number of variations  
available.  
Work Ports  
¾-16 UNF >\zn-18 UNF  
M\zn-20 UNF M\zn-20 UNF  
M\zn-20 UNF M\zn-20 UNF  
C\,-19  
¼
GAGE  
PORT  
Inlet  
Inlet with relief  
Outlet  
1.92 kg (4.2 lbs)  
1.88 kg (4.1 lbs)  
1.93 kg (4.3 lbs)  
PC  
(Hyd. Conn.)  
Work  
Sections  
¼
Work section with reliefs and  
manual actuator  
PT  
Work  
Z\, NPT  
Z\, NPT  
Z\, NPT  
Work section and manual actuator  
without reliefs  
1.98 kg (4.4 lbs)  
2.1 kg (4.6 lbs)  
0.8 kg (1.8 lbs)  
(Pneu.Conn.) Sections  
Work Section, PO Checks with  
manual actuator  
Joystick assembly  
Parker Hannifin Corporation  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Technical Information  
VO40  
Performance Curves  
Pressure Drop - Open Center PT  
Pressure Drop - Open Center PT  
Side Inlet to Side Outlet  
Top Inlet to Top Outlet  
PSI Bar  
217.5 15  
PSI Bar  
217.5 15  
P
T
P
T
174.0 12  
174.0 12  
130.5  
9
6
3
130.5  
9
6
3
8 Section Valve  
3 Section Valve  
1 Section Valve  
8 Section Valve  
3 Section Valve  
1 Section Valve  
87.0  
43.5  
87.0  
43.5  
0
0
10  
2.6  
30  
7.9  
10  
2.6  
30  
7.9  
LPM  
20  
5.3  
40  
10.6  
50  
13.2  
LPM  
20  
5.3  
40  
10.6  
50  
13.2  
0
0
GPM  
GPM  
Flow  
Flow  
Pressure Drop - PA  
Top Inlet to Cylinder Port  
Pressure Drop - AT  
Cylinder Port to Side Outlet  
PSI Bar  
217.5 15  
PSI Bar  
217.5 15  
A
P
T
8 Section Valve  
3 Section Valve  
1 Section Valve  
174.0 12  
174.0 12  
A
130.5  
9
6
3
130.5  
9
6
3
8 Section Valve  
3 Section Valve  
1 Section Valve  
87.0  
43.5  
87.0  
43.5  
0
0
10  
2.6  
30  
7.9  
10  
2.6  
30  
7.9  
LPM  
20  
5.3  
40  
10.6  
50  
13.2  
LPM  
20  
5.3  
40  
10.6  
50  
13.2  
0
0
GPM  
GPM  
Flow  
Flow  
NOTE: ISO VG 46 oil @ 50 °C  
Hydraulic Fluids  
Environmental Characteristics  
Best performance is obtained using mineral-base oil of  
high quality and cleanliness in the hydraulic system.  
The valve can be mounted in all conceivable directions.  
However, the mounting base should be flat and stable so  
that the valve is not subjected to strain.  
Hydraulic fluids of type HLP (DIN 51524), oil for automatic  
gearboxes Type A and engine oil type API CD can be  
used.  
While the o-rings in the valve are normally of nitrile rub-  
ber, there are a number of special fluorocarbon variants.  
Please contact Parker for further information.  
Viscosity, working range: 15-380 mm2/s (15-380 cST)**  
Temperature  
Technical information in this catalog is applicable at  
an oil viscosity of 30 mm2/s (30 cST) and temperature  
of 50 °C (122 °F) using nitrile rubber seals.  
Oil temperature, working range:  
+20°C to 90 °C (68 to 194 °F)*  
* Product operating limits are broadly within the above range, but  
satisfactory operation within the specification may not be accom-  
plished. Leakage and response will be affected when used at tem-  
perature extremes and it is up to the user to determine acceptability  
at these levels.  
Filtration  
Filtration must be arranged so that Target Contamination  
Class 20/18/14 according to ISO 4406 is not exceeded.  
For the pilot circuit, Target Contamination Class 18/16/13  
according to ISO 4406 must not be exceeded.  
** Performance efficiency will be reduced if outside the ideal values.  
These extreme conditions must be evaluated by the user to establish  
suitability of the product’s performance.  
Parker Hannifin Corporation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Technical Information  
VO40  
Circuit Types – Parallel Circuit  
In the open-center parallel circuit, oil flows through the open-center passage when all of the spools are in neutral.  
When spools are shifted, oil is diverted into the parallel path and available to each of the selected work-sections.  
Simultaneous operation can be achieved, when two or more spools are selected. However, since oil will take the  
path of least resistance the operator must meter the flow to each function to get a desired function speed.  
T1  
[24]  
P1  
[26]  
T4  
[34]  
B
B
B
A
A
A
G
Circuit Types – Tandem Circuit (Priority)  
In the open-center tandem circuit, oil flows through the open-center passage when all of the spools are in neutral.  
Tandem work-sections are fed from the open center and the parallel path is blocked. A tandem work-section will  
give priority to an upstream work-section.  
T1  
[24]  
T4  
[34]  
P1  
[26]  
A
B
A
B
A
B
Parker Hannifin Corporation  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Dimensions  
VO40  
Inch equivalents for millimeter dimensions are shown in (**)  
Assembly  
US  
207.5  
(8.16)  
B
A
B
32.0  
32.0  
(1.26)  
32.0  
(1.26)  
9.4 0.4  
(0.37 0.01)  
92.0 (3.62)  
87.0 (3.42)  
(1.26)  
15.0  
(0.59)  
70.0  
(2.76)  
140.0 161.8  
(5.51) (6.37)  
213.6  
(8.41)  
25.0  
(0.98)  
80.9  
(3.19)  
132.7  
(5.23)  
15°  
27.0  
(1.06)  
15°  
A = 76.0 (3.00) + 32.0 (1.26) x No. WORK STATIONS  
B = 32.0 (1.26) + 32.0 (1.26) x No. WORK STATIONS  
191.0 (7.51)  
Spool Stroke of Work Sections  
4-Position Spool  
(Float)  
3-Position Spool  
10°  
25.0  
(0.98)  
25.0  
(0.98)  
9.5  
(0.37)  
FLOAT STROKE  
5.5  
(0.22)  
5.5  
(0.22)  
5.5  
(0.22)  
5.5  
(0.22)  
84.0 (3.31)  
114.2 (4.50)  
STROKE STROKE  
STROKE STROKE  
Parker Hannifin Corporation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Dimensions  
VO40  
Mechanical Joystick  
Inch equivalents for millimeter dimensions are shown in (**)  
295  
(11.6)  
58  
(2.3)  
58  
(2.3)  
94  
(3.7)  
Float  
137  
(5.4)  
Float  
102  
(4.0)  
43  
(1.7)  
18  
(0.7)  
Pneumatic Actuator  
37.0  
(1.46)  
30.0  
(1.18)  
92.0  
(3.62)  
Dual Actuator  
6.00  
(0.236)  
16.25  
(0.640)  
62.0 (REF)  
(2.44)  
5.50  
(0.216)  
Handle Rod  
42  
30  
R9  
M8x1  
20  
R1  
140  
Parker Hannifin Corporation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Technical Information  
VO40  
Handle Actuation vs. Spool Direction  
A
B
Push Handle  
TANK  
TANK  
Spool Out  
Energize port “B”  
Port “A” to tank  
OPEN  
CENTER  
OPEN  
CENTER  
PARALLEL  
PATH  
PARALLEL  
PATH  
Pull Handle  
Note:  
Spool In  
Circuit reflects spool  
position, not handle  
position.  
Energize port “A”  
Port “B” to tank  
Right-Hand Joystick  
Left-Hand Joystick  
Spool OUT - Section 2  
Power to “B” Port  
Spool OUT - Section 1  
Power to “B” Port  
Spool OUT – Section 1  
Power to “B” Port  
Spool OUT – Section 2  
Power to “B” Port  
Spool IN – Section 2  
Power to “A” Port  
Spool IN – Section 1  
Power to “A” Port  
Spool IN – Section 2  
Power to “A” Port  
Spool IN – Section 1  
Power to “A” Port  
Parker Hannifin Corporation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information  
VO40  
How to Order the VO40 Valve Assembly  
A specification sheet is located in the back of this book, and is also available in an electronic Excel format on our  
web site. This form should be used to configure a valve assembly. The layout starts from the inlet cover on the left,  
work sections and mid-inlets in the middle and the outlet cover on the far right. Each field will require an entry, and  
the fields are represented with a position reference [ ] to help guide you to the option codes listed in the catalog  
pages 11 to 21.  
Inlet Cover Portion of Spec Sheet  
Code Position Reference  
Example: Inlet Cover (Sect #1)  
Customer Information  
Customer has 23 l/min pump flow, requires  
a pilot operated main relief set 140 bar and  
wants all SAE-8 work ports.  
Section Number  
starting with the Inlet Cover  
CUSTOMER  
• Reference position [4] calls out the thread  
option for the entire valve assembly (SAE  
or BSP) (“U8” is the code for all SAE-8  
size ports).  
CITY:  
DATE:  
STATE:  
FILLED BY:  
G = ALL PORTS 3/8" BSP  
U = ALL PORTS 9/16" UNF (SAE #6)  
U8 = ALL PORTS 3/4" UNF (SAE #8)  
U6 = P AND T 3/4" UNF AND WORK PORTS 9/16" UNF  
[04] CONNECTIONS  
Note: There is a separate specification  
sheet which utilizes metric units.  
U8  
THREAD  
• Reference position [12] calls out the  
system flow and can be listed in LPM or  
GPM depending on which spec sheet you  
are using (23 is entered for flow).  
STACK POS  
# 1  
# 2  
INLET  
WORK SECTION  
pos  
description  
12 Max. Inlet flow (GPM)  
15 Type of Inlet  
pos  
description  
• Reference position [15] gives you an  
option for a standard type inlet “I” or  
an unloader type inlet cover “IU” (“I” is  
entered for std inlet cover).  
47 Circuit type  
23  
I
50 Spool actuator  
16 Main relief valve  
51 Lever Bracket / handle  
51C Clevis or Handle location  
52 Spool pos. indication  
60 Spool function  
PB  
140  
23  
17 Pressure setting (PSI)  
17C Relief Flow Setting (GPM)  
24 Tank connection T1  
25 Tank connection T2  
26 Pump connection P1  
27 Pump connection P2  
P/N SECTION  
• Reference position [16] indicates the type  
of main relief valve: (“PB” is the code for  
a pilot operated RV).  
T1  
62 Piston head side  
76A Port A valve  
T2B  
P1B  
P2  
• Reference position [17] Enter desired  
relief valve setting (140 bar is entered).  
76B Port B valve  
• Reference position [17C] Enter desired  
flow for relief valve setting (23 l/min is  
entered).  
88A Restrictor on port A  
88B Restrictor on port B  
P/N MCH. CAST  
SPACER SECTION  
• Reference position [24-27] calls out the  
inlet/outlet porting (machined/plugged)  
options:  
90 Spacer Section  
MID INLET  
93 Mid Inlet type  
T1 is the top tank port open.  
94 Main relief valve  
98 Pressure setting (PSI)  
98C Relief Flow Setting (GPM)  
T2B is code for side tank port plugged.  
P1B is code for top inlet port plugged.  
P2 is code for top inlet port open.  
Parker Hannifin Corporation  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information  
VO40  
Valve Assembly – General Information  
The VO40 has two basic thread versions - UNF (SAE) or BSP.  
[04] – Connections Thread  
G
3/8 BSP Inlet, Outlet & Work Ports.  
U
9/16" UNF (SAE-6) Inlet, Outlet & Work Ports.  
9/16" UNF (SAE-6) Work Ports, 3/4" UNF (SAE-8) Inlet/Outlet Ports.  
3/4" UNF (SAE-8) Inlet, Outlet & Work Ports.  
U6  
U8  
[05] – System Voltage To be determined when the solenoid option is released  
[07] – Surface Treatment (Paint)  
X
P
No Paint.  
Paint valve black.  
[08] – Customer Designated ID: Enter Customer Part Number  
Parker Hannifin Corporation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Inlet Cover  
VO40  
The inlet cover of VO40 is available in two versions. One is the standard inlet and the other is an inlet with a sole-  
noid pump unloader (in development). The porting location options for the standard inlet are:  
1) Top/side – inlet and outlet ports. Any unused ports can be plugged.  
2) Top – inlet and outlet ports only.  
All inlet bodies have a gage port, that comes plugged. SAE #4 (7/16"x20 UNF thread) or 1/4" BSP.  
The coding to specify an inlet cover is accomplished by eight fields, as shown below:  
[12] – Max Pump Flow  
The pump inlet flow can be selected in LPM or GPM.  
[15] – Type of Inlet  
I
Standard Inlet.  
IU  
Inlet with pump unload, solenoid actuated (in development).  
[24] to [27] – Inlet Porting Options  
1) Standard – Top & Side Inlet/Outlet Ports  
2) Standard – Top Inlet/Outlet Ports  
OUTLET  
INLET  
INLET  
OUTLET  
GAGE  
TANK  
GAGE  
TANK  
TANK  
OPEN  
CENTER  
OPEN  
CENTER  
INLET  
PARALLEL  
PATH  
PARALLEL  
PATH  
Parker Hannifin Corporation  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Inlet Cover  
VO40  
[16] - Main Relief Options  
PS  
PB  
Adjustable main pilot-operated relief.  
Adjustment range: 50 to 300 bar (725 to 4300 PSI).  
Adjustable main pilot-operated relief  
(Tamperproof aluminum cap).  
Adjustment range: 50 to 300 bar (725 to 4300 PSI).  
PN  
PA  
Adjustable main direct-acting relief.  
Adjustment range: 60 to 207 bar (900 to 3000 PSI).  
Adjustable main direct-acting relief  
(Tamperproof aluminum cap).  
Adjustment range: 60 to 207 bar (900 to 3000 PSI).  
Y
Y plug (cavity machined and plugged).  
[17] – Pressure Setting – Enter pressure setting (PSI or Bar)  
Note: Relief valve code PN and PA max setting is  
207 bar (3000 PSI).  
[17C] – Relief Flow Setting  
Flow in LPM or GPM.  
Parker Hannifin Corporation  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Outlet Cover  
VO40  
The VO40 outlet cover is available in two versions: Standard or with pilot generation and regulation for proportional  
solenoid applications.  
The standard outlet has two porting configurations available:  
1) Top and side outlet ports along with machining for conversion to power-beyond or closed-center.  
2) Top outlet only.  
The coding to specify an outlet is made by four fields as shown below:  
[30] – Type of Outlet  
US  
Standard.  
USP With pilot-pressure generation (to be used on solenoid valves) (in development).  
[33] to [35] – Outlet Porting Options  
2) Top Oulet Port Only  
1) Top and Side Oulet Ports  
OUTLET  
OUTLET  
OUTLET  
TANK  
TANK  
OPEN  
CENTER  
OPEN  
CENTER  
OUTLET  
Parker Hannifin Corporation  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Outlet Cover  
VO40  
[33] to [35] – Outlet Porting Options  
Closed-Center  
Power-Beyond  
OUTLET  
OUTLET  
OUTLET  
TANK  
OUTLET  
TANK  
CLOSED  
OPEN  
OPEN  
CENTER  
POWER  
BEYOND  
CENTER  
CENTER  
PLUG  
Parker Hannifin Corporation  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Work Sections  
VO40  
The VO40 valve can be supplied in combinations from one to ten work sections. For each work section there is  
a variety of spool options, actuators, positioners and port accessories. Work sections can have parallel, series,  
and/or tandem circuitry. All types can be combined in the same valve assembly.  
All work sections with hold in neutral spools have transition checks (load checks). All work sections with free flow  
in neutral spools (motor) do not include transition checks (load checks). Contact Parker if you require a deviation  
from this configuration.  
Work sections are available with or without work port option machining. Integrated pilot-operated checks (Lock-  
Out) are available in a specially machined casting (ordering code on page 20 [76 A/B]). A spacer section which  
provides for more spacing between sections is also available (ordering code on page 20 [90]).  
Examples of work port machining options:  
Section without RV Cavities  
Section with RV Cavities  
Section with PO Checks  
The VO40 Pilot-Operated Check (Lock-Out) sections  
provide near zero leakage and can prevent cylinder  
drift when the spool is in the neutral position. When  
the spool is shifted to a power position, oil is directed  
to one work port. Return oil is momentarily blocked  
until pilot pressure unseats the check (3.1:1 ratio). With  
207 bar (3000 PSI) load, it will require 67 bar (968 PSI)  
into the opposite work port to unlock.  
The spool is a 4-way, 3-position free flow spool which  
prevents system pressure leakage from building up  
and unlocking the PO checks.  
The coding to specify a work section is made by 11 fields, as shown below:  
[47] – Work Section Circuitry  
P
T
S
Parallel Circuitry.  
Tandem Circuitry – Provides priority to upstream sections.  
Series Circuitry– (In development).  
Parker Hannifin Corporation  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Work Sections  
VO40  
[50] – Spool Actuators  
C
CD  
C
Spring centered to neutral position.  
CD  
Spring centered with dual control.  
CHA2 Two position detent – spool “IN”.  
Detent in neutral and “A” positions.  
CHA2  
CHB2  
CHB3  
CHB2 Two position detent – spool “OUT”.  
Detent in neutral and “B” positions.  
CHB3 Three position detent.  
B2A Spring centered with “IN” detent.  
Detent in “A” position and spring centering  
to neutral position.  
B2A  
B2B  
B2C  
B2B Spring centered with “OUT” detent.  
Detent in “B” position and spring centering  
to neutral position.  
B2C Spring centered with detent in two  
positions “A” & “B”.  
CB  
PC  
CB  
Spring centered with detent in fourth  
position, used with float spool.  
PC  
EC  
Hydraulic Remote Actuator – Proportional.  
Solenoid Operated – Proportional.  
(in development)  
ED  
Solenoid Operated – On/Off.  
ACP Pneumatic actuator – single ended.  
The pneumatic actuator for the VO40 allows the  
spool to be operated by a pneumatic signal. The  
pneumatic actuator is assembled onto one side  
of the work section and the opposite end is open  
and available for the addition of a handle. A min.  
of 5.5 bar (80 PSI) is required. The threaded  
ports are both 1/8" NPT.  
Parker Hannifin Corporation  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Work Sections  
VO40  
[51] – Lever Bracket Note: Handle Levers are sold separately (see PN listed below)  
SH  
SR  
Standard enclosed handle bracket.  
Standard enclosed handle bracket, but rotated 180 degrees.  
/
No bracket, no handle, no boot (female clevis on spool).  
LU  
No bracket, but with boot protector at spool end  
(female clevis on spool).  
MJL Mechanical Joystick – left side version (must be placed on two adjacent work sections).  
MJR Mechanical Joystick – right side version (must be placed on two adjacent work sections).  
Handle Rod Assembly is sold as a separate line item PN: K-VO40-H1.  
[51C] – Spool Clevis or Handle Bracket Location  
This field is used to indicate the location of the handle lever and bracket assembly –  
adjacent to port “A” or port “B” side of the work section.  
A
B
Spool Clevis or Handle Bracket on port “A” side.  
Spool Clevis or Handle Bracket on port “B” side.  
[52] – Spool Position Indication  
/
Without spool position indicator.  
SD  
With micro-switch on-off indicator (in development).  
Parker Hannifin Corporation  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Work Sections  
VO40  
[60] – Spool Function  
D
Double-acting (4-way) spool. Work ports blocked in the  
neutral position.  
EA  
EB  
M
Single-acting (3-way) spool. Port “A” blocked in neutral.  
Port “A” is active and Port “B” is plugged.  
Single-acting (3-way) spool. Port “B” blocked in neutral.  
Port “B” is active and Port “A” is plugged.  
Double-acting (4-way) spool. Work ports open to tank in the  
neutral position. Note: A work section with this spool does  
not have a transition check (load check).  
F
Double-acting (4-way) spool with a 4th position in which  
both work ports are connected to tank (float position).  
Work ports are blocked in the neutral position.  
DM  
Double-acting (4-way) spool. Work port pressure is bled to  
tank, when the spool is in the neutral position.  
Bleed notch is designed for 1.9 LPM @ 69 bar.  
(0.5 GPM @1000 PSI)  
DA  
DB  
Double-acting (4-way) spool. Work port “A” pressure is bled  
to tank, when the spool is in the neutral position.  
Bleed notch is designed for 0.5 GPM @1000 PSI.  
(1.9 LPM @ 69 Bar)  
Double-acting (4-way) spool. Work port “B” pressure is bled  
to tank, when the spool is in the neutral position.  
Bleed notch is designed for 0.5 GPM @1000 PSI.  
(1.9 LPM @ 69 Bar)  
Parker Hannifin Corporation  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Work Sections  
VO40  
[62] – Piston Head Side of Cylinder  
The default for this field is code M. Codes A and B are only used when asymmetrical spools must be developed.  
For example, a cylinder that requires meter-in for one direction and meter-out for the other.  
M
A
B
Standard symmetrical spool- cylinder or motor.  
Piston head connected with port “A”.  
Piston head connected with port “B”.  
Anti-Cavitation  
Check  
RV/AC Non-Adjustable  
[76 A/B] – Work Port Valves  
This pertains to the work port accessory options.  
/
Port not machined.  
Y2  
N2  
( )  
Relief Valve cavity plugged.  
Anti-cavitation valve.  
Y plug for blocking  
RV/AC Non-Adjustable: Enter Pressure setting (PSI or Bar).  
Note: RV Set at 10 LPM (2.6 GPM).  
RV cavity  
C2  
Pilot-Operated Checks (Lock-out valve).  
Refer to page 16.  
[88 A/B] – Work Port Option  
/
No Restrictor.  
Work port restrictors restrict flow in one direction  
and are free flow in the opposite direction.  
Restrict flow “out” of actuator “into” work port.  
Restrict flow “out” of work port “into” actuator.  
ACTUATOR  
METER IN  
ACTUATOR  
METER OUT  
P1 = 1mm (0.040")  
P2 = 2mm (0.080")  
N1 = 1mm (0.040")  
N2 = 1mm (0.080")  
P3 = 3mm (0.120")  
N3 = 1mm (0.120")  
P4 = 4mm (0.160")  
N4 = 1mm (0.160")  
[90] – Spacer Section  
N
Spacer Section.  
This section connects the open center, parallel path  
and tank cores between two adjacent work sections.  
This section is used to provide additional spacing  
between two work sections. All other fields in the  
work section code can be left blank. (Contact Parker  
for size options available.)  
TANK  
TANK  
OPEN  
CENTER  
OPEN  
CENTER  
PARALLEL  
PATH  
PARALLEL  
PATH  
Parker Hannifin Corporation  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Ordering Information – Mid-Inlet  
VO40  
The VO40 mid-inlet options are split or combined flow. They are available with a main RV option. There is also a  
provision for an outlet port on the split flow version only.  
The coding to specify a mid-inlet is made by three fields as shown below:  
Mid-Inlet  
Relief Valve  
Combined Flow, C3  
Split Flow, C5  
Mid-Inlet  
Pump Port  
INLET  
Optional  
Outlet Port  
C5 Only  
INLET  
OUTLET  
TANK  
TANK  
TANK  
TANK  
OPEN  
CENTER  
OPEN  
CENTER  
OPEN  
CENTER  
OPEN  
CENTER  
PARALLEL  
PATH  
PARALLEL  
PATH  
PARALLEL  
PATH  
[93] – Mid Inlet Options  
C3  
C5  
Combined Flow (Port “A” inlet - Port “B” is plugged and not available to tank).  
Split Flow (Port “A” inlet - Port “B” is optional tank port).  
[94] – Main Pressure Relief  
Y
Without pressure relief (cavity machined and plugged).  
PA  
Direct-acting relief valve non-adjustable.  
[98] – Pressure Setting - Enter pressure (PSI or Bar)  
[98C] – Mid-Inlet Relief Flow Setting  
Flow in GPM or LPM.  
Parker Hannifin Corporation  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Open-Center Directional Control Valve  
Catalog HY17-8505/UK  
Assembly Configuration Form  
VO40  
E E R F  
E E R F  
Parker Hannifin Corporation  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Extensive Hydraulic Product Offering  
Accumulators  
Compact Hydraulics  
Cylinders  
Electronics/Remote  
Controls  
Parker’s unique IQAN ap-  
proach combines sturdy,  
well-tested hardware with  
intelligent, flexible compu-  
ting power.  
Piston, bladder and di-  
aphragm type accumulators, gear pump, reservoir, inter-  
gas bottles and KleenVent  
reservoir isolators.  
Self-contained with a motor,  
Standard and custom  
hydraulic cylinders for  
industrial and mobile  
applications.  
nal valving, load hold checks  
and relief valves.  
Filtration  
Integrated Hydrau-  
lic Circuits  
Motors  
Power Take Off  
Solutions for complex circu-  
its that include threaded  
filters enhances machine life, cartridge valves integrated  
Pressure and return line  
Full line of high and low  
speed motors provides power industry for engineering,  
Parker Chelsea leads the  
reduces maintenance and  
lowers costs.  
into a single manifold.  
up to 1700 Nm of torque.  
innovation and performance  
in auxiliary power systems.  
Power Units  
Pumps  
Rotary Actuator  
Valves and Controls  
Industry leader in the design  
and manufacture of hydrau- Hydraulic valves for virtual-  
lic rack and pinion, and  
vane style rotary actuators.  
The most complete line of  
standard, pre-engineered,  
cataloged hydraulic power  
units in the industry.  
Broad line of energy- ef-  
ficient hydraulic pumps that  
includes piston, vane and  
gear pumps.  
ly every hydraulic equipment  
application, from simple to  
precise control.  
Covering the Industrial, Mobile  
and Truck markets, each catalog  
is paired with an interactive CD.  
Call for your comprehensive  
guides today. 00800 27 27 5374  
(from AU,BE,CH,DE,EI,FR,UK  
only) All other countries should  
call one of the following:  
+44 1442 358 429  
(English speaking service)  
+44 1442 358 428  
(German speaking service)  
+44 1442 358 427  
Industrial Bulletin  
HY02-8022  
Truck Bulletin  
HY02-8020  
Mobile Bulletin  
HY02-8023  
(French speaking service)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hydraulics Group  
Sales Offices  
Europe  
International  
Austria  
Wiener Neustadt  
Italy  
Corsico (MI)  
Australia  
Castle Hill  
Tel.: +43 (0)2622 23501  
Fax: +43 (0)2622 66212  
Tel.: +39 02 45 19 21  
Fax: +39 02 4 47 93 40  
Tel.: +61 (0)2 9634 7777  
Fax: +61 (0)2 9842 5111  
Austria  
The Netherlands  
Oldenzaal  
Tel.: +31 (0)541 585 000  
Fax: +31 (0)541 585 459  
Canada  
Wiener Neustadt  
(Resp for East Europe)  
Milton, Ontario  
Tel.: +1 905 693 3000  
Fax: +1 905 876 0788  
Tel.: +43 (0)2622 23501 970  
Fax: +43 (0)2622 23501 977  
Norway  
Ski  
Tel.: +47 64 91 10 00  
Fax: +47 64 91 10 90  
China  
Shanghai  
Tel.: +86 21 5031 2525  
Fax: +86 21 5834 8975  
Belgium  
Nivelles  
Tel.: +32 (0)67 280 900  
Fax: +32 (0)67 280 999  
Poland  
Warsaw  
Tel.: +48 (0)22 573 24 00  
Fax: +48 (0)22 573 24 03  
Asia Pacific Group  
Hong Kong  
Tel.: +852 2428 8008  
Fax: +852 2425 6896  
Czech Republic  
Klecany  
Tel.: +420 284 083 111  
Fax: +420 284 083 112  
Portugal  
Leca da Palmeira  
Tel.: +351 22 999 7360  
Fax: +351 22 996 1527  
India  
Mumbai  
Tel.: +91 22 5613 7081/82-85  
Fax: +91 22 2768 6841/6618  
Denmark  
Ballerup  
Tel.: +45 43 56 04 00  
Fax: +45 43 73 31 07  
Slovakia  
Ref. Czech Republic  
Japan  
Tokyo  
Tel.: +81 3 6408 3900  
Fax: +81 3 5449 7201  
Finland  
Vantaa  
Tel.: +358 20 753 2500  
Fax: +358 20 753 2200  
Spain  
Madrid  
Tel.: +34 91 675 73 00  
Fax: +34 91 675 77 11  
Latin America Group  
Brazil  
Tel.: +55 51 3470 9144  
Fax: +55 51 3470 9281  
France  
Contamine-sur-Arve  
Tel.: +33 (0)4 50 25 80 25  
Fax: +33 (0)4 50 25 24 25  
Sweden  
Spånga  
Tel.: +46 (0)8 59 79 50 00  
Fax: +46 (0)8 59 79 51 10  
South Africa  
Kempton Park  
Tel.: +27 (0)11 961 0700  
Fax: +27 (0)11 392 7213  
Germany  
Kaarst  
Tel.: +49 (0)2131 4016 0  
Fax: +49 (0)2131 4016 9199  
United Kingdom  
Warwick  
Tel.: +44 (0)1926 317 878  
Fax: +44 (0)1926 317 855  
USA  
Ireland  
Dublin  
Tel.: +353 (0)1 466 6370  
Fax: +353 (0)1 466 6376  
Cleveland (industrial)  
Tel.: +1 216 896 3000  
Fax: +1 216 896 4031  
Lincolnshire (mobile)  
Tel.: +1 847 821 1500  
Fax: +1 847 821 7600  
Parker Hannifin is the world’s premier supplier of motion and control systems and  
solutions, with sales and manufacturing facilities throughout the world. For product  
or call free on 00800 2727 5374.  
Catalogue HY17-8505/UK  
POD 04/2007 PC  
© Copyright 2007  
Parker Hannifin Corporation  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Moxa Technologies Network Cables 1130 User Manual
MTD Chipper 645B thru 651B User Manual
MTD Trimmer YM132 User Manual
Musical Fidelity Stereo Amplifier M3I User Manual
National Mower Lawn Mower 68 DL User Manual
Numark Industries Music Mixer DM 1835X User Manual
Omnitron Systems Technology Network Card 100Fx Tx User Manual
Oster Toaster 140495 User Manual
Panasonic Network Card 2SD0592 User Manual
Panasonic Pedicure Spa EP30102 User Manual