T9P new (6) 7/17/02 6:05 PM Page 1
R
INSTRUCTION MANUAL
Automatic Blood Pressure Monitor
and Print-Out with IntelliSense™
Model
T9P
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 3
INTRODUCTION
Thank you for purchasing the Omron Automatic Blood Pressure Monitor
and Print-Out with IntelliSenseTM, T9P. Although your blood pressure
fluctuates throughout the day, no self-adjustment is necessary
as the monitor intelligently adjusts to your changing conditions. The
IntelliSenseTM monitor uses fuzzy logic intelligence to sense both your
systolic and diastolic blood pressure values, and the result is personalized
inflation with every reading. Arm discomfort and misreading due to
improper cuff inflation are virtually eliminated.
Your new OMRON monitor uses the oscillometric method of blood
pressure measurement. This means the monitor detects your blood’s
movement through your brachial artery and converts the movements into
a digital reading. At the push of a button, the monitor automatically fills
the cuff with air, starts deflation, then displays your systolic, diastolic,
and pulse readings on an extra large display panel.
Please read this instruction manual thoroughly before using
this unit. For specific information on your own blood pressure,
CONTACT YOUR DOCTOR.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (10) 8/6/02 2:31 PM Page 4
NOTES ON SAFETY
[
[
The warning signs and the sample icons shown here are listed for you to use the product safely and correctly
as well as to prevent the risk and the damage to you and others from happening.
The icons and meanings are as follow.
Warning sign
Contents
Indicates matters in which bodily harm or material damage* may arise as a result
of incorrect handling.
Caution
* Material damage refers to a wide range of damage involving your house, household goods,
domestic animals, and pets.
Examples of signs
The
icon indicates prohibitions (what you cannot do).
Matters involving actual prohibitions are indicated by text or pictures in or near
.
The
icon indicates something compulsory (always follow). Matters involving actual
compulsory actions are indicated by text or pictures in or near
to "general compulsion".
. The left icon refers
Caution
Self-diagnosis of measured results and treatment are dangerous. Please follow
the instructions of your doctor.
Do not use the unit on infants or persons who cannot express one’s intention.
Do not use the unit for any purpose other than measuring blood pressure.
Do not use a cellular phone near the unit.
Improper operation may result.
Do not disassemble, repair, or remodel the main unit or the arm cuff
of the blood pressure monitor.
The battery liquid may leak and damage the main unit. Please observe the following points.
[
When you are not going to use the unit for a long period of time (approximately three
months or more), take out the batteries.
Replace the worn batteries with new ones immediately.
Do not use worn and new batteries together.
Do not insert the batteries with their polarities in wrong direction.
[
[
[
Do not force to bend the arm cuff or the air tube excessively.
When removing the air tube, pull at the connector.
Do not apply strong shock or drop the main unit.
Do not inflate the arm cuff without it being wrapped on the arm.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 5
KNOW YOUR UNIT
Main Unit:
AC Adapter Jack
Heart Symbol
Adjust Date/Time
Set Date/Time
Systolic Blood Pressure
Printer Jack
Cuff Jack
ON/OFF Button
Diastolic Blood Pressure
START Button
Pulse Rate
Memory Call Button
Date/Time Display
Printer-Unit:
Printer Cover
Printer Cable Plug
Power/Operation
Light
Paper Feed
Print Current Data/Stop Printing
Print Graph
Print All Data
Accessories:
Arm Cuff
(Applicable arm
cuff for Adults
22 to 32 cm.)
AC Adapter
Air Plug
(Connects to Air Jack)
Air Tube
(not a standard accessory)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 6
QUICK REFERENCE GUIDE
1. Avoid eating, smoking, and exercising for at least 30 minutes before
taking a measurement.
2. Remove tight-fitting clothing from your upper arm.
3. Sit in a chair with your feet flat on the floor and place your arm
on a table so that the cuff is at the same level as your heart.
4. Put your arm through the cuff loop making sure that the bottom edge
of the cuff is approximately 1-2 cm above the elbow and that
the Green Marker on the cuff is above brachial artery.
1-2 cm
Green Marker
5. Pull the end of the cuff so that the entire cuff is evenly tightened
around your arm and press the hook material firmly against the pile
side of the cuff.
6. Press the ON/OFF button.
7. After the Heart Symbol ( ) appears on the digital panel, press the Start
button, and remain still until the measurement is complete.
8. When measurement is complete, the monitor displays your blood
pressure and pulse rate, and automatically deflates the cuff.
9. Wait 2-3 minutes before taking another blood pressure measurement.
You may require more rest time between readings depending
on your individual physiological characteristics.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:23 PM Page 7
BATTERY INSTALLATION/REPLACEMENT
Main Unit:
Printer Unit:
1. Slide the battery cover off
in the direction of the arrow.
2. Install or replace 4 "AA"
size batteries so the +
(positive) and – (negative)
polarities match the polarities
of the battery compartment
as indicated.
3. Replace the battery cover.
Notes:
If the Low Battery Indicator
(
) appears on the display,
replace all four batteries.
Long-life alkaline batteries
are recommended.
Remove the batteries if the
monitor will not be used for
an extended period of time.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 8
HOW TO SET TIME AND DATE
1. When the batteries are installed, the
display will show 12:00a.m.
2. Press and hold the “SET” button. The
year digits (2001) will flash.
3. Press the “ADJUST” button to
advance the digit(s) one at a time.
If you hold down the ADJUST
button, the digits will advance rapidly.
4. Press “SET” button when desired
number is on the display to lock setting.
5. Repeat Step 3-4 for month and date.
6. Repeat Step 3-4 for hour and
minutes.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 9
HOW TO USE THE
OPTIONAL AC ADAPTER
To avoid potential damage to the monitor, use only the optional
AC adapter specified by Omron distributor.
To connect the AC adapter
1. Insert the AC adapter plug into the AC Adapter jack on the back of
the main unit.
2. Plug in the AC adapter into the appropriate AC outlet.
To remove the AC adapter
To remove the AC adapter,
disconnect the adapter plug
1
from the AC outlet first and
then disconnect the cord from
the monitor’s jack.
2
NOTE: The monitor is designed not
to draw power from the
batteries when the AC
adapter is in use.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/22/02 9:47 AM Page 10
HOW TO APPLY THE ARM CUFF
1. If the cuff is assembled correctly, the
SYSTOLIC
hook material will be on the outside of
DIASTOLIC
the cuff loop and the metal D-ring will
not touch your skin.
PULSE/min
2. If the cuff is not assembled, pass
the end of the cuff furthest from
the tubing through the metal D-ring
to form a loop. The smooth cloth
should be on the inside of the cuff loop.
Pile Side Material
Sewn Hook Material
3. Sit in a chair with your feet flat on the
floor and place your arm on a table
so that the cuff is at the same level
as your heart.
D-Ring
4. Put your arm through the cuff
loop. The bottom of the cuff should
be approximately 1-2 cm
above the elbow. The Green
Marker on the cuff should lie
over the brachial artery on the
inside of the arm. Tube
Bottom Edge 1-2 cm
should run down center of
arm approximately even
with middle finger.
Cuff Tube
Green Marker
10
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 11
HOW TO APPLY THE ARM CUFF
5. Pull the cuff so that the top and
bottom edges are tightened
evenly around your arm.
6. When the cuff is positioned
correctly, press the sewn hook
material FIRMLY against the
pile side of the cuff.
7. Make certain the cuff fits
snugly around your arm.
The cuff should make
good contact with
your skin.
You should be able
to fit your index finger
between the cuff and your
arm easily, so you can pull
the cuff off and on.
8. Relax your arm and turn your
palm upward.
9. Be sure there are no kinks
in the air tubing.
You can also measure blood
pressure on your right arm.
Wrap the arm cuff as shown in
Mark cloth
the Figure.
1. Place the air tube below the
elbow.
2. Place the mark cloth inside the
Air tube
elbow joint of your right arm.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 12
HOW TO TAKE A READING
1. Press the ON/OFF button.
a) All display symbols appear for approximately
one second.
b) When the monitor becomes ready to measure,
the Heart Symbol appears on the display.
2. Press the START button and remain still.
As the cuff begins to inflate, the monitor automatically
determines your ideal inflation level. Because this
monitor detects the pulse even during inflation, do not
move your arm and remain still until the entire
measurement completes.
3. Inflation stops automatically
and measurement is started.
As the cuff slowly deflates, decreasing
numbers appear on the display and the Heart Symbol
(
) flashes at every heartbeat. In rare circumstances,
a higher inflation may be necessary. In those cases,
the monitor reinflates the cuff up to 30 mmHg higher
than initial inflation and restarts the measurement.
4. When the measurement is complete,
the arm cuff completely deflates and
your blood pressure and pulse rate
are displayed.
Deflation
Inflation
NOTE: The monitor automatically stores blood pressure
and pulse rate into the memory.
5. Press the ON/OFF button to turn the
monitor off.
NOTE: If you forget to turn the monitor off, it will
automatically shut itself off after five minutes.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 13
HOW TO TAKE A READING
Instructions for special conditions:
[
If your systolic pressure is known to
be more than 220 mmHg, push and
hold the START button until the
monitor inflates 30 to 40 mmHg
higher than your suspected systolic
pressure.
NOTE: Do not apply more
pressure than necessary.
The monitor will not inflate
above 300 mmHg.
START
[
If you want to stop the measurement,
push the ON/OFF button. The monitor
will stop inflating and start deflating
rapidly, then the monitor will turn off.
Continue to press button
13
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/22/02 9:46 AM Page 14
HOW TO USE THE MEMORY FUNCTION
This monitor has a memory capable of storing twenty-eight (28) sets of readings.
Every time you complete the measurement, the monitor automatically
stores blood pressure and pulse rate.
[
Push the
button to recall stored readings while the Heart
Symbol ( ) is displayed.
[
When twenty-eight (28) sets of readings are stored in memory, the
oldest set will be deleted to store a new set.
alternately displayed
[
[
Date and Time of stored readings will be alternately displayed.
To delete stored readings, press the
button and the
Start button simultaneously, then all the readings will be deleted.
NOTE: You cannot delete the stored readings partially.
START
Press these two buttons
at the same time.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 15
HOW TO CONNECT PRINTER UNIT
1. Remove printer cable plug from
around printer unit.
2. Connect printer cable plug cord to the
main unit. Arrow (8) on printer cable
plug should face down
to main unit.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 16
HOW TO LOAD PRINTER PAPER
1. Open printer cover in the direction
indicated by the arrow symbol and
remove paper roll from the main unit.
10 cm
2. Peel off the glued edge of the printing
paper included with the unit, and cut
the first 10 cm with a pair of scissors.
3. Press the PAPER FEED button while
inserting the edge of the printing paper
into the paper feeding slot. When the
edge of the paper protrudes sufficiently,
release the PAPER FEED button.
4. Close the plastic printer cover. Make
certain that the paper sticks out from
the top when the cover is replaced.
5. Thermal sensitive paper is supplied
with the unit. Use only thermal paper
of similar size (width approx. 38mm)
and roll diameter (not to exceed
approx. 26mm). These rolls of paper
(model number HEM - PAPER -
759P) can be ordered from OMRON
distributors.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 17
HOW TO USE THE PRINTER-UNIT
The T9P has the ability to print all the readings stored in memory.
NOTE:
[
Make sure printer-unit is connected to main unit (see How to
Connect Printer-Unit)
[
Do not use printer-unit without loading printer paper (see How
to Load Printer Paper). Improper use will decrease operation life
cycle of printer-unit.
[
Main unit does NOT have to be ON to operate printer-unit.
[
Printer-unit will automatically shut OFF when printing is
completed.
[
If you need to stop printing during printing process, press
“DATA/STOP” button.
1. Press “DATA/STOP” to print measurement of
most recent reading.
The numeric print-out will look like the
following example:
Time
Month/Date
7/9
6:36 AM
SYS
Systolic Reading
Diastolic Reading
Pulse Reading
111mmHg
DIA
PULSE
67mmHg
77/min
2. Press “ALL DATA” button to print a numerical
list and average of all stored readings (stores a
maximum of 28 readings).
17
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 18
HOW TO USE THE PRINTER-UNIT
The numerical print-out will list all stored readings (maximum of 28
readings) starting with the most recent reading to last stored reading:
Diastolic Reading
Column
Systolic Reading
Column
Pulse Reading
Column
Month(s)
3-6
D. T.
mmHg
/min
SYS DIA PUL
Date
20 15
23 11
1 15
3 14
113
117
113
110
112
110
106
110
108
111
107
111
121
112
112
75
69
71
67
66
61
66
65
61
56
64
64
62
64
65
67
64
63
66
64
64
65
64
67
62
64
64
66
63
65
Last reading stored
Time/Hour
5
7
15 7
20 12
3 12
10 12
12 14
14 7
21 15
22 12
Most recent reading
4
6
*AV.
Average of all
stored readings
[
[
[
Month(s)
The month or months will be printed.
Example: If the blood pressure reading was stored between months
March-June, then the printout will indicate “3-6”.
Date
Only the day’s date (1-31) will be printed.
Example: If the blood pressure reading was stored on June 1st, then the
printout will indicate 1 under the “D” column.
Time/Hour
Only the hour (24 hour format) will be printed.
Example: if the blood pressure reading was stored at 3:00 PM, then
the printout will indicate 15 under the “T” column.
Note: If Time and Date was not initially set up before taking blood pressure measurement
(see How to Set Time and Date) on printer-unit, the numerical value will not appear on
print-out for month, time/hour and date.)
18
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 19
HOW TO USE THE PRINTER-UNIT
3. Press “GRAPH” button to print a graph
of all stored readings (stores a maximum
of 28 readings).
Month(s)
mmHg
200
3-6
50
100
150
Last reading stored
If reading is lower
than 50 mmHg or
higher than 200
mmHg, (; or :)
will appear.
Diastolic Reading
Systolic Reading
Most recent reading
Average diastolic
reading of stored
measurements
Average systolic
reading of stored
measurements
19
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (8) 7/29/02 11:30 AM Page 20
TROUBLESHOOTING
Main Unit:
Error Indicator
Cause
Correction
Turn monitor off, wait 2-3 minutes
and take another measurement.
Repeat steps listed under "How to
Take a Reading." If "EE" is
displayed again, take another
measurement by pressing and
holding the START button as shown
on instruction page 13 under "How
to Take a Reading", instructions
for special conditions.
Cuff under-inflated.
Movement during
measurement.
Your cuff maybe wrapped too
tightly around your arm.
Turn the monitor off, carefully
read and repeat steps listed
under "How to Take a Reading."
Cuff over-inflated
(more than 300 mmHg).
Battery voltage
is excessively low.
Replace all four "AA" batteries
with new batteries.
Contact your nearest OMRON
representative or dealer.
Problem caused by abnormal
memory function.
If you continue to have difficulty obtaining a reading, contact your nearest OMRON
representative or dealer.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 21
TROUBLESHOOTING
Printer Unit:
Error Indicator
Cause
Correction
Printer cable plug is not
connected properly or
damaged
Connect correctly Reference p.15
Replace with new batteries
Take measurement then print
Batteries are worn
No readings stored
Nothing is printed
Printer paper is not installed
correctly
Install correctly
Power/Operation light is
blinking, stopped printing
Replace with new batteries
Batteries are worn
No printer paper installed
Printer paper jammed
Ran out of printer paper
Take paper jammed from the
printer and install again
No printer paper comes out
Purchase new printer paper
If you continue to have difficulty printing, contact your nearest OMRON representative
or dealer.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 22
CARE AND MAINTENANCE
To protect your monitor from damage, please AVOID the following:
[
Subjecting your monitor and cuff to extreme temperatures,
humidity, moisture, and direct sunlight.
[
Folding the cuff and tubing tightly.
[
Inflating the monitor over 280 mmHg.
[
Disassembling the monitor.
[
Subjecting the monitor to strong shocks
(for example, dropping the monitor on the floor.)
[
Do not clean the monitor with volatile liquids.
THE MONITOR SHOULD BE CLEANED WITH
A SOFT, DRY CLOTH.
[
Do not clean cuff.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (9) 8/1/02 3:06 PM Page 23
SPECIFICATIONS
MAIN UNIT:
Model:
T9P
Display:
LCD Digital Display
Measurement Range:
Pressure: 0 to 299 mmHg
Pulse: 40 to 180/minute
Accuracy/Calibration:
Pressure: 4 mmHg
Pulse: 5% of reading
Inflation:
Deflation:
Automatic by electric pump
Active electronic control valve
Active electronic control valve
Capacitive pressure sensor
Oscillometric method
Rapid Pressure Release:
Pressure Detection:
Measurement Method:
Pulse Wave Detection:
Power Source:
Capacitive pressure sensor
4 "AA" batteries or optional AC adapter
Approximately 300 uses
Battery Life:
Operating
10°C to 40°C
Temperatures/Humidity:
Storage
30 to 85% RH maximum
–20°C to 60°C
Temperatures/Humidity:
Main Unit Weight:
Main Unit Dimensions:
Cuff Dimensions:
Cuff Circumference:
Accessories:
10 to 95% RH maximum
Approximately 380g not including batteries
Approximately 115 mm (l) x 177 mm (w) x 71 mm (h)
Approximately 140 mm x 480 mm
Fits arm circumference 22 ~ 32 cm
Arm cuff, printer-unit, paper rolls (2), instruction manual
PRINTER UNIT:
Power Source:
Battery Life:
Paper Usage:
Printer Weight:
Printer Dimensions:
4 “AA” batteries
Approximately 300 uses (current data)
Approximately 200 uses for 1 roll (current data)
Approximately 170 g (not including batteries)
Approximately 123 mm x 72 mm x 50 mm
NOTE: These specifications are subject to change without notice.
*Optional accessories: large cuff (fits arms 32 to 38 cm circumference) and small cuff (fits
arms 17 to 22 cm circumference) are sold separately.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 24
ABOUT BLOOD PRESSURE
What Causes High Blood Pressure ?
Blood pressure is only classed as high if it doesn’t go down when you rest.
Permanently raised blood pressure can be caused by several factors such as
hardening of the arteries, smoking or drinking too much alcohol. It can also be
caused by cholesterol, a type of fat, building up inside your blood vessels and
making them narrower. Being under stress can add to the problem.
High blood pressure is also known to run in families hence if you find you have a
high blood pressure it is a good idea to test other closely related members of your
family.
Fluctuation within a Day
(Example: 35-year-old male)
Blood pressure
(mmHg)
Breakfast
Rest room
300
Dinner
Sleep
Lunch
250
200
150
100
50
Systolic
blood
pressure
Diastolic
blood
pressure
Time
17 : 00
0
17 : 00
23 : 00
5 : 00
11 : 00
Brachial blood pressure data
Why is it a Good Thing To Measure Blood Pressure at Home ?
Having your blood pressure measured by a doctor can cause anxiety which is a
cause itself of high blood pressure. As a variety of conditions affect blood pressure,
a single measurement may not be sufficient for an accurate diagnosis.
The blood pressure measured first thing in the morning after getting up, before
eating and while at rest, is known as the fundamental blood pressure. In practice it
is rather difficult to record the fundamental blood pressure, but it is important to get
readings in an environment that is as close as possible to this.
Classification of Blood Pressure by the World
Heath Organization
Systolic blood pressure
(mmHg)
The World Health Organization (WHO) and the
International Society of Hypertention (ISH) developed
the Blood Pressure Classification shown in this figure.
Severe hypertension
180
Moderate hypertension
160
This classification is based on the blood presure values
Mild hypertension
140
measured on people in a sitting position in outpatient
Nomal systoric value
departments of hospitals.
130
Nomal blood pressure
120
*There is no universally accepted definition of hypotension.
However, those having the systolic pressure below 100 mmHg are
assumed as hypotensive.
Optimal biood
pressure
(target value)
Diastoric
blood
pressure
(mmHg)
90
100
110
80
85
According to the blood pressure classification by the WHO/ISH* (revised in 1999)
* International Society of Hypertension
24
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 25
Product of OMRON Corporation, Japan
OMRON Healthcare Singapore Pte Ltd
83, Clemenceau Avenue
#11-01, UE Square
Singapore 239920
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
T9P new (6) 7/17/02 6:05 PM Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
|