Omron Healthcare Blood Pressure Monitor HEM 432C User Manual

R
INSTRUCTION MANUAL  
MANUAL INFLATION  
BLOOD PRESSURE MONITOR  
Model  
HEM-432C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing the Omron HEM-432C Manual Inflation  
Blood Pressure Monitor.  
Fill-in for future reference  
DATE PURCHASED: ______________  
SERIAL NUMBER: ________________  
Staple your purchase receipt here.  
The monitor features an easy-to-squeeze inflation bulb that allows  
you to quickly inflate the cuff. The measurement reading is clearly  
displayed on a large digital panel.  
Omron digital blood pressure monitors use the oscillometric method  
of blood pressure measurement. This means the monitor detects  
your blood’s movement through your brachial artery and converts the  
movements into a digital reading. An oscillometric monitor does not  
need a stethoscope so the monitor is simple to use.  
The Omron HEM-432C Manual Inflation Blood Pressure Monitor  
is intended for home use.  
SAVE THESE INSTRUCTIONS  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY NOTES  
To assure the correct use of the product basic safety measures should  
always be followed including the precautions listed below:  
Read all information in the instruction book and any other literature  
included in the box before using the unit.  
Contact your physician for specific information about your blood  
pressure. Follow the instructions of your healthcare provider.  
Operate the unit only as intended. Do not use for any other purpose.  
The unit is intended for use in measuring blood pressure and pulse  
rate in adult patient population. Do not use on infants.  
Do not use a cellular phone near the unit. It may result in  
operational failure.  
Changes or modifications not approved by Omron Healthcare will  
void the user warranty. Do not disassemble or attempt to repair the  
unit or components.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
KNOW YOUR UNIT  
Systolic Blood Pressure Display  
MEMORY Button  
Diastolic Blood Pressure /  
ON/Off Button  
Pulse rate Display  
Arm Cuff  
Air Release Button  
Air  
Inflation Bulb  
Air Tube  
Air Tube  
Air Tube  
(Connects to  
the air plug)  
(Connects to  
the air plug)  
Air Plug  
Air Plug  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK REFERENCE GUIDE  
1. Avoid eating, smoking, and exercising for at least 30 minutes before  
taking a measurement.  
2. Put your left arm through the cuff loop. The bottom of the cuff  
should be about 1/2 inch above the elbow. The cuff tab should lie  
over the brachial artery on the inside of the arm.  
3. Pull the cuff so that it is tightened evenly around your arm. Insert one  
finger under cuff to check fit. Press the sewn hook material firmly  
against the pile side of the cuff. Make sure that your skin will not be  
pinched in the D-ring once you inflate the cuff. Immediately deflate  
the cuff and readjust it if skin becomes pinched.  
4. Sit in a chair with your feet flat on the floor and place your left arm  
on a table so that the cuff is at the same level as your heart.  
5. Turn the monitor on, and after the Ready To Measure Symbol (  
)
appears next to a zero on the digital panel, rapidly squeeze the  
inflation bulb to inflate the cuff. Stop pumping when the numbers  
on the display are approximately 40 mmHg higher than your  
normal systolic blood pressure. Do not inflate over 280 mmHg.  
6. The cuff will deflate automatically. Remain still throughout  
the entire reading.  
7. When measurement is complete, the monitor alternately displays  
your blood pressure/ pulse rate on the digital panel. Press the Air  
Release Button to remove air in the cuff.  
8. Wait 2-3 minutes before taking another blood pressure measurement.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY INSTALLATION / REPLACEMENT  
1. Slide the battery cover off in the direction  
of the arrow.  
2. Install 4 “AA” size batteries so + (positive)  
and – (negative) polarities match the polarities  
of the battery compartment as indicated.  
3. Replace the battery cover.  
NOTE: If the Low Battery Indicator appears on the  
display, replace all four batteries.  
Long-life alkaline batteries are recommended.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
To keep your digital blood pressure monitor in the best condition and  
protect the unit from damage follow the directions listed below:  
Clean the monitor with a soft dry cloth. Do not use any abrasive or  
volatile cleaners. Do not attempt to clean the cuff. Never immerse the  
monitor or any components in water.  
Store the monitor in a safe and dry location. Do not fold the cuff  
and tubing tightly. Do not subject the monitor to extreme hot or cold  
temperatures, humidity and direct sunlight.  
Avoid subjecting the monitor to strong shocks, such as dropping the  
unit on the floor.  
Remove the batteries if the unit will not be used for three months or  
longer. Always replace all the batteries with new ones at the same time.  
Use the unit consistent with the instruction provided in this manual.  
Use only authorized parts and accessories.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO APPLY THE ARM CUFF  
Pile Material  
1. If the cuff is assembled correctly, the sewn  
hook material will be on the outside  
of the cuff loop and the metal D-ring  
will not touch your skin.  
Sewn Hook  
Material  
2. Pass the end of the cuff furthest from  
the tubing through the metal D-ring to  
form a loop. The smooth cloth should  
be on the inside of the cuff loop.  
D-Ring  
Smooth Cloth  
3. Put your left arm through the cuff loop.  
The bottom of the cuff should be  
approximately 1/2 inch above the  
elbow. The cuff tab on the cuff  
should lie over the brachial  
1/2 inch (12.7 mm)  
artery on the inside of the arm.  
Tube should run down center  
of arm even with middle finger.  
Cuff tab  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO APPLY THE ARM CUFF  
4. Pull the cuff so that the top and bottom edges are  
tightened evenly around your arm.  
5. When the cuff is positioned correctly, press the  
sewn hook material FIRMLY against the pile  
side of the cuff.  
6. Make certain the cuff fits snugly around your arm.  
The cuff should make good contact with your skin.  
7. Sit in a chair with your feet flat on the floor and  
place your arm on a table so that the cuff is at the  
same level as your heart.  
8. Relax your arm and turn your palm upward.  
9. Be sure there are no kinks in the air tubing.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO TAKE A MEASUREMENT  
Please read “How To Apply The Arm Cuff” before  
taking a reading.  
1. Press the ON/OFF Button.  
a) All display symbols appear for about one second.  
This is the initial LCD Test.  
Initial  
LCD Test  
b) The display symbols disappear and the Deflation  
Indication Symbol ( ) starts to flash.  
Deflation  
Indication  
c) When the monitor completes the necessary  
preparations before measurement, the Heart Symbol  
(
) appears next to a zero. Wait for the Heart  
Ready  
To Measure  
Symbol ( ) before taking a measurement.  
2. Begin inflating the cuff by rapidly squeezing the inflation  
bulb until you have reached approximately 40 mmHg higher  
than your normal systolic reading. If your normal systolic  
blood pressure is unknown, inflate the cuff to 180 mmHg.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO TAKE A MEASUREMENT  
3. Remain still. The cuff will begin to deflate automatically.  
4. As the cuff deflates, decreasing numbers  
appear on the display. The Heart Symbol  
(
) flashes at every heartbeat.  
Indicated  
Value Drops  
Measuring  
5. When measurement is complete, the Heart  
Symbol ( ) stops flashing and your blood  
pressure and pulse rate are displayed alternately.  
6. When the Deflation Indication Symbol  
(
) appears on the display, push the  
Blood Pressure  
Reading Display  
(for approx.  
3.5 sec.)  
Air Release Button to release any  
air left in the cuff.  
Pulse Reading  
Display  
(for approx. 2 sec.)  
NOTE: Wait 2-3 minutes before taking  
another blood pressure measurement.  
Waiting between readings allows the  
arteries to return to the condition prior  
to taking the blood pressure measurement.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE THE MEMORY FUNCTION  
This monitor has a memory capable of storing fourteen (14) sets  
of readings. Every time you complete the measurement, the monitor  
automatically stores blood pressure and pulse rate.  
• Press the ON/Off Button.  
• Press the MEMORY Button to recall stored readings while the  
Heart Symbol ( ) is displayed.  
• When fourteen (14) sets of readings are stored in memory, the oldest  
set will be deleted to store a new set.  
• To delete stored readings, press the MEMORY Button and the ON/OFF  
Button simultaneously for 2 seconds. All readings will be deleted.  
NOTE: You can not delete the stored readings partially.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR INDICATORS  
Error Symbol  
Correction  
Cause  
Cuff under-inflated.  
Wait 2-3 minutes and take  
another measurement.  
Repeat steps listed under  
“How To Take A Reading”.  
Inflate the cuff 40 mmHg  
higher than the previous  
inflation value.  
Movement during  
Measurement  
No pulse or blood pressure  
reading due to very weak  
artery pulse.  
Press Air Release Button  
for 4-5 seconds to release  
air pressure in cuff.  
Residual air pressure  
in cuff.  
Cuff over-inflated (more  
than 300 mmHg).  
Carefully read and repeat  
steps listed under “How  
To Take A Reading.”  
Batteries have run down. Replace all four  
“AA” batteries.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC STATEMENT  
Note:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class  
B digital device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. The product generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular  
installation. If the product does cause harmful interference to radio or television  
reception, which can be determined by turning the product on and off, the  
user is encouraged to try to correct the interference by one or more  
of the following measures:  
• Reorient or relocate the receiving antenna  
• Increase the separation between the product and the receiver.  
• Connect the product into an outlet on a circuit different from that to which  
the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE  
(for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise  
emissions from digital apparatus as set out in the interference-causing  
equipment standard entitled “ Digital Apparatus”, ICES-003 of the Canadian  
Department of Communications. Cet appareil numérique respecte les limites  
de bruits radioeléctriques applicables aux appareils numériques de Clase B  
prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques”,  
ICES-003 édictée par le minister des communications.  
Changes or modifications not expressly approved by the party responsible  
for compliance could void the user’s authority to operate the equipment.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
Limited Warranties  
Your HEM-432C Manual Blood Pressure Monitor, excluding the monitor cuff, is warranted  
to be free from defects in materials and workmanship appearing within 1 year, when  
used in accordance with the instructions provided with the monitor. The monitor cuff  
is warranted to be free from defects in materials and workmanship appearing within one  
year, when the monitor is used in accordance with the instructions provided with the monitor.  
The above warranties extend only to the original retail purchaser.  
We will, at our option, repair or replace without charge any monitor or monitor cuff covered  
by the above warranties. Repair or replacement is our only  
responsibility and your only remedy under the above warranties.  
To obtain warranty service, ship the monitor and all of the components, together with proof  
of purchase and a note explaining the problem with $5.00 for return shipping and insurance to:  
Omron Healthcare, Inc.  
Attn: Repair Department  
300 Lakeview Parkway  
Vernon Hills, IL 60061  
Be sure to include the model number, your name and your phone number on the enclosed  
note and any other correspondence.  
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR  
PURPOSE, ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN  
WARRANTY ABOVE. Some states do not allow limitations on how long an implied  
warranty lasts, so the above limitation may not apply to you.  
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL,  
CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES. Some states do  
not allow the exclusion or limitation of incidental  
or consequential damages, so the above exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which may  
vary from state to state.  
FOR CUSTOMER SERVICE  
Visit our web site at:  
Call toll free:  
1-800-634-4350  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Model:  
HEM-432C  
Display:  
LCD Digital Display  
Measurement Range:  
Pressure: 0 to 280 mmHg  
Pulse: 40-180/min.  
Accuracy/Calibration:  
Pressure: 3mmHg or 2% of reading  
Pulse: 5% of reading  
Manual by inflation bulb  
Automatic pressure release valve  
Push button valve  
Inflation:  
Deflation:  
Rapid Air Release:  
Pressure Detection:  
Measurement Method:  
Pulse Wave Detection:  
Power Source:  
Battery Life:  
Capacitive pressure sensor  
Oscillometric method  
Capacitive pressure sensor  
4 "AA" batteries  
Approximately 1000 uses  
Operating Temperature/  
50°F to 104°F (10°C to 40°C)  
30 to 85% RH maximum  
Humidity:  
Storage Temperature/  
Humidity:  
-4°F to 140°F (-20°C to 60°C)  
10 to 95% RH maximum  
Console Weight:  
Outer Dimensions:  
Cuff Dimensions:  
Approximately 13 oz. (350g) with cuff,  
exclude batteries  
Approximately 4 1/8" (w) x 3 3/8" (h)  
x 4 1/2" (d) (106mm x 84mm x 116mm)  
Approximately 5 3/4" (w) x 18 7/8" (l)  
(145mm x 480mm)  
Arm Circumference Range:  
Accessories:  
UPC Code:  
Approximately 9'' to 13'' (220mm - 320mm)  
Arm cuff, Inflation bulb, Instruction manual  
0 73796 04322 3  
NOTE: These specifications, to improve performance, are subject to change without notice.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Made in China  
Manufactured by:  
OMRON HEALTHCARE, INC.  
300 Lakeview Parkway  
Vernon Hills, Illinois 60061  
Copyright © 2003 Omron Healthcare, Inc.  
432CINST Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Home Theater System V560 User Manual
NETGEAR Network Card FA311 User Manual
NETGEAR Network Router WNDR4300v2 User Manual
Newcon Optik Binoculars NVS 14 3GCS User Manual
Olympus Microcassette Recorder VN 702PC User Manual
Omega Speaker Systems Thermometer OSXL650 User Manual
Oricom Cordless Telephone ECO80 User Manual
Panasonic CD Player CT 27G12 User Manual
Panasonic Computer Monitor BT LH2600W User Manual
Paradyne Modem 7110 SNMP User Manual