Omron Healthcare Blood Pressure Monitor BP755 User Manual

INSTRUCTION MANUAL  
Automatic Blood Pressure Monitor  
with ComFitCuff  
Model BP755  
BP755  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing Omron® BP755 IntelliSense® Automatic  
Blood Pressure Monitor with the ComFitCuff.  
Fill in for future reference.  
DATE PURCHASED: __________________  
SERIAL NUMBER: ____________________  
Staple your purchase receipt here  
Your new digital blood pressure monitor uses the oscillometric method  
of blood pressure measurement. This means the monitor detects your  
blood’s movement through your brachial artery and converts the  
movements into a digital reading. An oscillometric monitor does not  
need a stethoscope so the monitor is simple to use.  
The BP755 comes with the following components:  
• Monitor  
• AC Adapter  
• ComFitCuff  
• Storage Case  
• Quick Start Guide  
• Instruction Manual printed in English and Spanish  
The BP755 IntelliSense® Automatic Inflation Blood Pressure Monitor is  
intended for home use.  
SAVE THESE INSTRUCTIONS  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
To assure the correct use of the product, basic safety measures should  
always be followed including the warnings and cautions listed in this  
instruction manual.  
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL  
Indicates a potentially hazardous situation  
which, if not avoided, could result in death or  
serious injury.  
WARNING  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor or  
CAUTION  
moderate injury to the user or patient or  
damage to the equipment or other property.  
OPERATING THE DEVICE  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may be  
dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
The monitor is not intended to be a diagnostic device.  
If battery fluid should get in your eyes, immediately rinse with  
plenty of clean water. Contact a physician immediately.  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
OPERATING THE DEVICE (continued)  
This device is intended for use in measuring blood pressure and  
pulse rate in the adult population. Do not use this device on infants  
or persons who cannot express their intentions.  
Read the Special Conditions section (page 24) of the instruction  
manual if your systolic pressure is known to be more than 220  
mmHg. Inflating to a higher pressure than necessary may result in  
bruising where the cuff is applied.  
Operate the device only as intended. Do not use the device for any  
other purpose.  
Dispose of the device, components and optional accessories  
according to applicable local regulations. Unlawful disposal may  
cause environmental pollution.  
Do not use a cellular phone near the device. It may result in an  
operational failure.  
Use only authorized parts and accessories. Parts and accessories not  
approved for use with the device may damage the unit.  
Use only 1.5 V “AA” alkaline batteries with this device. Do not use  
other types of batteries. This may damage the unit.  
RISK OF ELECTRICAL SHOCK  
Do not plug or unplug the power cord into the electrical outlet with  
wet hands.  
Do not overload power outlets. Plug the device into the appropriate  
voltage outlet.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
CARE AND MAINTENANCE  
Do not subject the monitor to strong shocks, such as dropping the  
unit on the floor.  
Do not submerge the device or any of the components in water.  
Store the device and the components in a clean, safe location.  
Changes or modification not approved by the manufacturer will void  
the user warranty. Do not disassemble or attempt to repair the unit or  
components.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE TAKING A MEASUREMENT  
To ensure a reliable reading follow these recommendations:  
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for  
30 minutes before taking a measurement. Rest for at least 15 minutes  
before taking the measurement.  
2. Stress raises blood pressure. Avoid taking measurements during  
stressful times.  
3. Measurements should be taken in a quiet place.  
4. Remove tight-fitting clothing from your left arm.  
5. Sit on a chair with your feet flat on the floor. Rest your left arm on a  
table so that the cuff is at the same level as your heart.  
6. Remain still and do not talk during the measurement.  
7. Wait 2-3 minutes between measurements. The wait time allows the  
arteries to return to the condition prior to taking the blood pressure  
measurement. You may need to increase the wait time depending on  
your individual physiological characteristics.  
8. Keep a record of your blood pressure and pulse readings for your  
physician. A single measurement does not provide an accurate  
indication of your true blood pressure. You need to take and record  
several readings over a period of time. Try to measure your blood  
pressure at the same time each day for consistency.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
KNOW YOUR UNIT  
Main Unit:  
Display  
Battery Compartment  
B
P
7
5
5
Start/Stop  
Button  
Memory Buttons  
Air Jack  
Date/Time Setting Button (  
)
AC Adapter Jack  
Components:  
Air Tube  
Thumb Grip  
Air Plug (Connects to Air Jack)  
Storage Case  
Arm Cuff  
Housing  
Cord  
INSTRUCTION MANUAL  
Automatic Blood Pressure Monitor  
with ComFitCuff  
Model BP755  
BP  
75  
5
AC Adapter  
Instruction Manual  
Quick Start Guide  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIT DISPLAY  
Systolic Blood Pressure  
Diastolic Blood Pressure  
Heartbeat Symbol/  
Hypertension Indicator  
Memory Symbol  
Average Value Symbol  
Pulse Display  
Deflation Symbol  
Movement Error Symbol  
Date/Time Display  
Battery Low Indicator  
Irregular Heartbeat Symbol  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISPLAY SYMBOLS  
IRREGULAR HEARTBEAT SYMBOL (  
)
When the monitor detects an irregular rhythm two or more times during  
the measurement, the Irregular Heartbeat Symbol ( ) will appear on  
the display with the measurement values.  
Normal Heartbeat  
An irregular heartbeat rhythm is defined  
as a rhythm that is more than 25%  
slower or 25% faster from the average  
rhythm detected while the monitor is  
measuring the systolic and diastolic  
blood pressure.  
Pulse  
Blood  
pressure  
Irregular Heartbeat  
Short Long  
If the irregular heartbeat symbol (  
)
Pulse  
displays with your measurement results,  
we recommend you consult your  
physician. Follow the directions of your  
doctor.  
Blood  
pressure  
MOVEMENT ERROR SYMBOL (  
)
The Movement Error Symbol ( ) is displayed if you move your body  
during the measurement. Please remove the arm cuff, and wait  
2-3 minutes, reapply the arm cuff and take another measurement.  
AVERAGE VALUE SYMBOL (  
)
The Average Value Symbol ( ) is displayed when you press the  
Memory button. The most recent average reading appears on the display  
screen.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISPLAY SYMBOLS  
HEARTBEAT SYMBOL/HYPERTENSION INDICATOR  
(
)
TAKING A MEASUREMENT  
The Heartbeat Symbol ( ) flashes on the display during the  
measurement. The Heartbeat Symbol ( ) flashes at every  
heartbeat.  
When the measurement is complete, the Heartbeat Symbol (  
)
flashes on the display with your blood pressure and pulse rate if the  
reading is above 135 for the Systolic Blood Pressure value and/or  
above 85 for the Diastolic Blood Pressure value.  
USING THE MEMORY FUNCTION  
The Heartbeat Symbol ( ) flashes when the blood pressure  
reading stored in the memory is above 135 for the Systolic Blood  
Pressure value and/or above 85 for the Diastolic Blood Pressure  
value.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISPLAY SYMBOLS  
The American Heart Association recommends the following guideline  
for upper limit of normal for home blood pressure readings:  
AHA Home Guideline for Upper Limit of Normal BP  
Systolic Blood Pressure  
135 mmHg  
Diastolic Blood Pressure  
85 mmHg  
This is a general guideline because blood pressure depends on  
age and morbidity. The AHA recommends a lower home blood  
pressure goal for certain patients, including diabetic patients,  
pregnant women, and patients with renal failure1.  
WARNING  
The monitor is not intended to be a diagnostic device.  
WARNING  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may  
be dangerous. Follow the instructions of your physician or  
licensed healthcare provider.  
Omron Healthcare recommends you contact your physician if the  
Heartbeat Symbol ( ) flashes on the display with your measurement  
values.  
1American Heart Association Scientific Statement 2004  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE AC ADAPTER  
IMPORTANT SAFETY INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
- DANGER -  
TO REDUCE THE RISK OF  
FIRE OR ELECTRIC SHOCK,  
CAREFULLY FOLLOW THESE INSTRUCTIONS.  
For connection to a power supply not in the U.S.A., use an  
attachment plug adapter of the proper configuration for the  
power outlet.  
The power unit (AC Adapter) is intended to be correctly  
oriented in a vertical or floor mount position.  
NOTES: • Use only the authorized Omron AC Adapter that came with  
this monitor.  
• We recommend you install the batteries even if the AC  
Adapter is used. If no batteries are installed, you may need  
to reset the date and time if the AC Adapter is disconnected.  
The measurement results will not be deleted.  
CAUTION  
Use only authorized parts and accessories. Parts and accessories not  
approved for use with the device may damage the unit.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE AC ADAPTER  
To connect the AC Adapter  
Insert the AC Adapter Plug into the AC Adapter Jack on the back side  
of the monitor as illustrated.  
Plug the AC Adapter into a 120V AC outlet (60 cycles).  
Housing  
Cord  
To disconnect the AC Adapter  
Hold and pull the housing to remove the AC Adapter from the  
electrical outlet. Do not remove by pulling the cord.  
Remove the AC Adapter plug from the monitor.  
WARNING  
Do not plug or unplug the power cord into the electrical outlet with  
wet hands.  
CAUTION  
Do not overload power outlets. Plug the device into the appropriate  
voltage outlet.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY INSTALLATION  
NOTE: Use 4 new “AA” size batteries - long life alkaline batteries are  
recommended.  
1. Press the indicator on the battery cover  
and slide the cover off in the direction of  
the arrow.  
2. Install 4 “AA” size batteries so the  
+ (positive) and - (negative) polarities  
match the polarities of the battery  
compartment as indicated.  
NOTE: 4 “AA” size batteries are not  
included in this unit.  
3. Replace the battery cover.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY INSTALLATION  
BATTERY REPLACEMENT  
Low Battery Indicator  
When the Low Battery Indicator appears on the display screen, turn the  
monitor off and remove all the batteries. Replace with four new batteries  
at the same time. Long-life alkaline batteries are recommended.  
WARNING  
If battery fluid should get in your eyes, immediately rinse with  
plenty of clean water. Contact a physician immediately.  
NOTES: • Turn the unit off before replacing the batteries. If the  
batteries are removed while the unit is still on, the date and  
time will be reset to that of the previous use. However, the  
measurement results are not deleted.  
• When the batteries are replaced, you may need to reset the  
date and time. If the year is flashing on the display screen,  
refer to “Setting the Date and Time”.  
CAUTION  
Dispose of the device, components and optional accessories  
according to applicable local regulations. Unlawful disposal may  
cause environmental pollution.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTING THE DATE AND TIME  
Set the monitor to the current date and time before taking a measurement  
for the first time. If the current date and time are not set correctly, the  
measurement values stored in the memory and the average values may  
not be correct.  
1. TO START THE SETTING  
Press the Date/Time Setting  
button ( ) to adjust the date  
and time.  
®
The year flashes on the display.  
2. SETTING THE YEAR  
The year can be set between  
2006 and 2030.  
When the display reaches 2030, it will return  
to 2006.  
Press the Memory Up button  
by increments of one year.  
to advance  
Press the Date/Time Setting button ( ) to set  
the current year.  
®
The month flashes on the display.  
NOTES: • Press the Memory Down button  
to decrease the day  
and time values by increments of one.  
• Press and hold the Memory button to increase or decrease  
the date and time values faster.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTING THE DATE AND TIME  
3. SETTING THE MONTH  
Press the Memory Up button  
of one month.  
to advance by increments  
Press the Date/Time Setting button ( ) to set  
the current month.  
®
The day flashes on the display.  
4. SETTING THE DAY  
Press the Memory Up button  
by increments of one day.  
to advance  
Press the Date/Time Setting button ( ) to set  
the current day.  
®
The hour flashes on the display.  
5. SETTING THE HOUR  
The time is set using AM or PM.  
Press the Memory Up button  
of one hour.  
to advance by increments  
Press the Date/Time Setting button ( ) to set  
the current hour.  
The minutes flash on the display.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTING THE DATE AND TIME  
6. SETTING THE MINUTE  
Press the Memory Up button  
of one minute.  
to advance by increments  
Press the Date/Time Setting button ( ) to set the current minute.  
The year flashes on the display.  
7. TO TURN THE MONITOR OFF  
Press the START/STOP button.  
NOTE: The monitor will automatically turn off after the minute has  
been set after battery replacement.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLYING THE ARM CUFF  
CAUTION  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
CAUTION  
This device is intended for use in measuring blood pressure and  
pulse rate in the adult population. Do not use this device on infants  
or persons who cannot express their intentions.  
APPLYING THE CUFF ON THE LEFT ARM  
1. Make sure the air plug is securely inserted in the main unit.  
T
R
A
T
S
P
O
T
S
Y
R
O
M
E
M
2. Remove tight-fitting clothing from your upper arm.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLYING THE ARM CUFF  
Thumb Grip  
3. Hold the thumb grip on the cuff  
securely with your hand.  
Cloth Fastening  
4. Turn the palm of your hand upward.  
5. Apply the cuff to your left upper arm so the blue stripe is on the  
inside of your arm and aligned with your middle finger. The air tube  
runs down the inside of your arm. The bottom of the cuff should be  
approximately 1/2" above your elbow.  
Left Arm  
Blue Stripe  
1/2 inch (1 - 2 cm)  
Air Tube  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLYING THE ARM CUFF  
6. Wrap the cuff firmly in place around your arm using the cloth  
fastening.  
APPLYING THE CUFF ON THE RIGHT ARM  
When taking a measurement using the right arm use this instruction  
for Step 5.  
Apply the cuff to your right upper arm so the thumb grip is centered on  
the inside of your inner arm. The bottom of the cuff should be  
approximately 1/2'' above your elbow.  
Right Arm  
Thumb Grip  
NOTE: Be careful not to rest your arm on the air tube. This will restrict  
the flow of air to the cuff.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TAKING A MEASUREMENT  
The monitor automatically determines your ideal inflation level. In rare  
circumstances when a higher inflation may be necessary, the monitor  
automatically re-inflates the cuff up to 30mmHg higher than the initial  
inflation and restarts the measurement.  
1. Sit on a chair with your feet flat on the floor. Place your arm on a  
table so the cuff is level with your heart.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TAKING A MEASUREMENT  
2. Press the START/STOP button.  
All display symbols appear on the screen.  
The cuff starts to inflate automatically. As the cuff inflates, the  
monitor automatically determines your ideal inflation level.  
Remain still and do not move your arm until the entire measurement  
process is completed.  
®
NOTE: To stop the inflation or measurement, push the START/STOP  
button. The monitor will stop inflating, start deflating, and will  
turn off.  
3. Inflation stops automatically and the measurement is started.  
As the cuff deflates, decreasing  
numbers appear on the display  
and the Heartbeat Symbol (  
flashes.  
)
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TAKING A MEASUREMENT  
4. When the measurement is complete, the arm  
cuff completely deflates. Your blood pressure  
and pulse rate are displayed.  
5. Press the START/STOP button to  
turn the monitor off.  
NOTE: The monitor will automatically  
®
turn off after five minutes.  
SPECIAL CONDITIONS  
CAUTION  
Inflating to a higher pressure than necessary may result in bruising  
where the cuff is applied.  
If your systolic pressure is known to be more than 220 mmHg,  
press and hold the START/STOP button until the monitor inflates  
30 to 40 mmHg higher than your expected systolic pressure.  
®
NOTES: • Do not apply more pressure than necessary.  
• The monitor will not inflate above 299 mmHg.  
When the measurement is complete, the arm cuff completely deflates.  
Your blood pressure and pulse rate are displayed.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE MEMORY FUNCTION  
Every time you complete a measurement the monitor stores the blood  
pressure and pulse rate in the memory. The monitor automatically stores  
up to 90 sets of measurement values (blood pressure and pulse rate).  
When 90 sets of measurement values are stored, the oldest record is  
deleted to save the most recent values.  
ADVANCED AVERAGING FUNCTION  
The monitor calculates the average reading based on the three most  
recent sets of measurement values taken within 10 minutes of the most  
recent reading.  
TO DISPLAY THE AVERAGE VALUE AND THE MEASUREMENT VALUES  
NOTE: If two sets of measurement values are stored in the memory for  
the 10 minute period, the average is based on the two sets of  
measurement values. If one set of measurement value is stored,  
this is displayed as the average.  
1. Press the Memory Down button  
. The average value symbol  
(
) appears on the display when the average reading is shown.  
®
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE MEMORY FUNCTION  
2. Press the Memory Down button  
set of measurement values on the screen.  
to display the most recent  
to display the oldest set of  
Press the Memory Up button  
measurement values.  
®
Alternating display  
NOTES: • The date and time are alternately displayed with the  
measurement values.  
• Press the button repeatedly to display the next values.  
• Press and hold the button to display the values faster.  
3. Press the START/STOP button to turn the power off.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE MEMORY FUNCTION  
TO DELETE ALL VALUES STORED IN THE MEMORY  
You cannot partially delete values stored in the memory.  
All values will be deleted.  
1. While holding the Memory Down button  
, press the  
START/STOP button down for more than 2 seconds until the display  
appears as it does in the following illustration.  
®
2. Press the START/STOP button to turn the monitor off.  
NOTE: The monitor will automatically turn off after five minutes.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care and Maintenance  
CARE AND MAINTENANCE  
To keep your digital blood pressure monitor in the best condition and  
protect the unit from damage, follow the directions listed below:  
Keep the monitor in the storage case  
when not in use. Make sure the AC Adapter  
is placed under the main unit so that is does  
not damage the display.  
Do not forcefully bend the arm cuff  
or air tube. Do not fold tightly.  
Clean the monitor with a soft dry cloth.  
Do not use any abrasive or volatile cleaners.  
Do not attempt to clean the cuff.  
CAUTION  
Do not submerge the device or any of the components in water. Do  
not subject the monitor to extreme hot or cold temperatures,  
humidity or direct sunlight.  
CAUTION  
Store the device and the components in a clean, safe location.  
CAUTION  
Do not subject the monitor to strong shocks, such as dropping the  
unit on the floor.  
Remove the batteries if the unit will not be used for three months or  
longer. Always replace all the batteries with new ones at the same time.  
Use the unit consistent with the instruction provided in this manual.  
Use only authorized parts and accessories.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
Use the unit in a manner consistent with the instructions provided  
in this manual.  
CAUTION  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage the  
unit.  
CAUTION  
Changes or modification not approved by the manufacturer will void  
the user warranty. Do not disassemble or attempt to repair the unit or  
components.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
SYMBOL  
CAUSE  
CORRECTION  
Take another measurement and  
remain still until the  
measurement is complete.  
Monitor could not  
detect pulse wave.  
Cuff under-inflated.  
Cuff not applied  
correctly.  
Remove the arm cuff.  
Read “Taking a Measurement”.  
Wait 2-3 minutes.  
Cuff over-inflated.  
Batteries are worn.  
Take another measurement.  
Replace the four batteries. Refer  
to “Battery Installation”.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
PROBLEM  
CAUSES AND SOLUTIONS  
No power.  
Replace all four batteries with new  
ones.  
No display appears on the unit. Check the battery installation  
for proper placement of the  
battery polarities.  
Blood pressure varies constantly.  
Many factors including stress, time  
of day, how you wrap the cuff, may  
affect your blood pressure.  
Review the sections “Before Taking  
Measurement values appear  
too high or too low.  
a Measurement” and “Taking a  
Measurement”.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC STATEMENT  
Note:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class B  
digital device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. The product generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular  
installation. If the product does cause harmful interference to radio or television  
reception, which can be determined by turning the product on and off, the  
user is encouraged to try to correct the interference by one or more of the  
following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the product and the receiver.  
• Connect the product into an outlet on a circuit different from that to which  
the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise  
emissions from digital apparatus as set out in the interference-causing equipment  
standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of  
Communications.  
Cet appareil numérique respecte les limites de bruits radioeléctriques  
applicables aux appareils numériques de Clase B prescrites dans la norme sur le  
materiel brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister  
des communications.  
Changes or modifications not expressly approved by the party responsible for  
compliance could void the user’s authority to operate the equipment.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
LIMITED WARRANTIES  
Your BP755 IntelliSense® Automatic Blood Pressure Monitor, excluding the arm cuff, is  
warranted to be free from defects in materials and workmanship appearing within 5 years  
from the date of purchase, when used in accordance with the instructions provided with  
the monitor. The arm cuff is warranted to be free from defects in materials and  
workmanship appearing within one year from the date of purchase when the monitor is  
used in accordance with the instructions provided with the monitor. The above warranties  
extend only to the original retail purchaser.  
We will, at our option, repair or replace without charge any monitor or arm cuff covered  
by the above warranties. Repair or replacement is our only responsibility and your only  
remedy under the above warranties.  
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the  
address of the repair location and the return shipping and handling fee.  
Enclose the Proof of Purchase. Include a letter, with your name, address, phone number,  
and description of the specific problem. Pack the product carefully to prevent damage in  
transit. Because of possible loss in transit, we recommend insuring the product with return  
receipt requested.  
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE  
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  
PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE  
APPLICABLE WRITTEN WARRANTY ABOVE. Some states do not allow  
limitations on how long an implied warranty lasts, so the above limitation may not apply  
to you.  
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER  
INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR  
DAMAGES. Some states do not allow the exclusion or limitation of incidental or  
consequential damages, so the above exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which  
may vary from state to state.  
FOR CUSTOMER SERVICE  
Visit our web site at:  
Call toll free:  
1-800-634-4350  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Model:  
BP755 (HEM-7000-Z4CS)  
Display:  
LCD Digital Display  
Measurement Range:  
Accuracy/Calibration:  
Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.  
Pressure: 3mmHg or 2% of reading  
Pulse: 5% of reading  
Inflation:  
Automatic by electric pump  
Deflation:  
Automatic pressure release valve  
Automatic exhaust valve  
Capacitive pressure sensor  
Rapid Air Release:  
Pressure Detection:  
Measurement Method:  
Pulse Wave Detection:  
Power Source:  
Battery Life:  
Operating Temperature  
/Humidity:  
Oscillometric method  
Capacitance type pressure sensor  
120V 60Hz AC Adapter (or 4 “AA” batteries)  
Approx. 1500 uses with 4 new alkaline batteries  
50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH  
Storage Temperature  
/Humidity/Air Pressure:  
Main Unit Weight:  
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH  
700-1060 hPa  
Approximately 12 1/2 oz. (355 g)  
not including batteries  
Main Unit Dimensions:  
Cuff Size:  
Approx. 6 3/32" (l) x 5 5/32" (w) x 3 5/16" (h)  
(155 mm x 131 mm x 84 mm)  
Approximately 6" (w)(152 mm)  
Cuff tube 23 5/8" (l) (600 mm)  
Fits arm circumferences 9" to 17"  
(220mm to 420mm)  
Cuff Circumference:  
Memory:  
Contents:  
Up to 90 readings  
Main Unit, ComFitTM Cuff, AC Adapter,  
Instruction Manual, Quick Start Guide, and  
Storage Case  
= Type B  
NOTE: These specifications are subject to change without notice.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufactured by OMRON HEALTHCARE  
Made in China  
Distributed by:  
OMRON HEALTHCARE, INC.  
1200 Lakeside Drive  
Bannockburn, Illinois 60015  
Copyright © 2009 Omron Healthcare, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Vacuum Cleaner S5981 User Manual
Milwaukee Power Hammer 5366 21 User Manual
Murphy Automobile Parts AT 04060N User Manual
Mustek Mouse KB3100 User Manual
Nikon Network Card SNT V504 User Manual
Nortel Networks Switch 241 5101 200 User Manual
Norton Abrasives Saw Cut Off Wheels For Metal Fabrication User Manual
Olivetti All in One Printer D COPIA 300MF User Manual
Omega Stud Sensor DMD 476 User Manual
OWI Portable Speaker BR8 User Manual