Display:  
3.2 How to Sit Correctly  
L
M
N
To take a measurement, you need  
to be relaxed and comfortably  
seated, under comfortable room  
temperature. No bathing, drinking  
alcohol or caffeine, smoking,  
exercising or eating 30 minutes  
before taking a measurement.  
Q
G
H
Wrist Blood  
I
Pressure Monitor  
R
S
J
Model RS3  
Instruction Manual  
• Sit on a chair with your feet flat on the  
floor.  
• Sit upright with your back straight.  
• The cuff should be at the same level  
as your heart.  
K
IM-HEM-6130-E-02-01/2013  
5338830-7B  
O
P
G. Memory symbol  
H. Systolic blood pressure  
I. Diastolic blood pressure  
J. Battery low symbol  
K. Heartbeat symbol  
(Flashes during measurement)  
L. Average value symbol  
M. Date/Time display  
N. Blood pressure level indicator  
O. Pulse display and Memory  
number  
Introduction  
• Relax your wrist and hand. Do not bend your wrist back, clench  
your fist, or bend your wrist forward.  
Thank you for purchasing the OMRON RS3 Wrist Blood Pressure  
Monitor.  
P. Deflation symbol  
The OMRON RS3 is a compact and easy to use blood pressure  
monitor, operating on the oscillometric principle. It measures your  
blood pressure and pulse rate simply and quickly. For comfortable  
controlled inflation without the need of pressure pre-setting or  
re-inflation the device uses its advanced “IntelliSense” technology.  
Q. Cuff wrapping guide  
R. Movement error symbol  
S. Irregular heartbeat symbol  
2. Preparation  
2.1 Installing/Replacing the Batteries  
Intended Use  
This product is designed to measure the blood pressure and pulse  
rate of people within the range of the designated wrist cuff, following  
the instructions in this instruction manual.  
3.3 Taking a Reading  
Notes:  
Remove the battery cover.  
To cancel a measurement, press the START/STOP button at  
any time during measurement.  
1.  
It is mainly designed for general household use. Please read the  
Important Safety Information in this instruction manual before using  
the unit.  
• Remain still while taking a measurement.  
Please read this instruction manual thoroughly before using the  
unit.  
Press the START/STOP button.  
1.  
All the symbols appear on the display.  
Please keep for future reference.  
The wrist cuff will start to inflate automatically.  
For specific information about your own blood pressure,  
CONSULT YOUR DOCTOR.  
Alternating  
date/time display  
Cuff Wrapping Guide  
Insert two 1.5V “AAA”  
2.  
Important Safety Information  
alkaline (LR03) batteries  
as indicated in the battery  
compartment and then  
replace the battery cover.  
Consult your doctor prior to using in pregnancy or if diagnosed with  
arrhythmia or arteriosclerosis.  
Please read this section carefully before using the unit.  
Warning:  
• Indicates a potentially hazardous situation which, if not avoided,  
could result in death or serious injury.  
Notes:  
START  
INFLATE  
DEFLATE  
COMPLETE  
• If the battery low symbol ( ) appears on the display, turn off  
(General Usage)  
the unit then replace both batteries at the same time.  
• The measurement values continue to be stored in memory  
even after the batteries are replaced.  
Cuff Wrapping Guide  
• Always consult your doctor. Self-diagnosis of measurement results  
and self-treatment are dangerous.  
The Cuff Wrapping Guide is a unique feature that  
indicates if the cuff is not wrapped tightly enough  
• People with severe blood flow problems, or blood disorders, should  
consult a doctor before using the unit, as cuff inflation can cause  
internal bleeding.  
Disposal of used batteries should be carried out in accordance  
with the national regulations for the disposal of batteries.  
around the wrist. Even when the  
blood pressure reading will be taken.  
is displayed, a  
(Battery Usage)  
2.2 Setting the Date and Time  
• If battery fluid should get in your eyes, immediately rinse with  
plenty of clean water. Consult a doctor immediately.  
Caution:  
Note: This reading is NOT reliable due to the incorrect  
wrapping of the cuff. Please wrap the cuff again, taking  
care to wrap it correctly and take the measurement  
1. Press and hold the  
button until the year  
flashes on the display.  
again. When the  
is displayed, the cuff is correctly  
• Indicates a potentially hazardous situation which, if not avoided,  
may result in minor or moderate injury to the user or patient or  
damage to the equipment or other property.  
(General Usage)  
wrapped tightly enough on the wrist and the reading is  
accurate and reliable.  
Set the monitor to the correct date and time  
before taking a measurement for the first time.  
2.  
• Do not leave the unit unattended with infants or persons who  
cannot express their consent.  
• Do not use the unit for any purpose other than measuring blood  
pressure.  
• Do not use a mobile phone or other devices that emit  
electromagnetic fields, near the unit. This may result in incorrect  
operation of the unit.  
• Do not disassemble the unit or wrist cuff.  
• Do not operate the unit in a moving vehicle (car, airplane).  
(Battery Usage)  
• If battery fluid should get on your skin or clothing, immediately rinse  
with plenty of clean water.  
• Use only two “AAA” alkaline (LR03) batteries with this unit.  
• Do not insert the batteries with their polarities incorrectly aligned.  
• Replace old batteries with new ones immediately. Replace both  
batteries at the same time.  
• Remove the batteries if the unit will not be used for three months or  
more.  
• Do not use new and used batteries together.  
General Precautions  
• Do not apply strong shocks and vibrations to or drop the unit.  
• Do not take measurements after bathing, drinking alcohol or  
caffeine, smoking, exercising or eating.  
• Do not inflate the wrist cuff when it is not wrapped around your  
wrist.  
• Read and follow the “Important information regarding Electro  
Magnetic Compatibility (EMC)” in the Technical Data Section.  
• Read and follow the “Correct Disposal of This Product” in the  
Technical Data Section when disposing of the device and any used  
accessories or optional parts.  
Undo the wrist cuff and remove the unit.  
2.  
3.  
1) Push the  
button to change.  
• Hold down to advance the digit  
rapidly.  
Press the START/STOP button to turn off the  
monitor.  
The monitor automatically stores the measurement in its  
memory.  
2) Push the  
button to confirm.  
• Next setting appears.  
It will automatically turn off after two minutes.  
Important:  
• Recent research suggests that the  
following values can be used as a  
guide to high blood pressure for  
measurements taken at home.  
Year  
Month  
Day  
Systolic Blood Pressure  
Diastolic Blood Pressure  
Above 135 mmHg  
Above 85 mmHg  
Hour  
Minute  
This criteria is for home blood pressure measurement.  
Press the START/STOP button to store the  
3.  
• Your blood pressure monitor includes an  
irregular heartbeat feature. Irregular  
setting.  
Notes:  
heartbeats can influence the results of the  
measurement. The irregular heartbeat  
algorithm automatically determines if the  
measurement is usable or needs to be  
repeated. If the measurement results are  
affected by irregular heartbeats but the result  
is valid, the result is shown together with the  
irregular heartbeat symbol ( ).  
• If the batteries have been removed, the date and time setting  
will need to be reset.  
• If the date and time are not set, “-:--” appears during or after  
measurement.  
3. Using the Unit  
3.1 Applying the Wrist Cuff  
If the irregular heartbeats cause the measurement to be  
Do not apply over clothing.  
invalid, no result is shown. If the irregular heartbeat symbol  
1. Overview  
Main unit:  
(
) is shown after you have taken a measurement, repeat  
Place the wrist cuff over  
your wrist.  
1.  
the measurement. If the irregular heartbeat symbol ( ) is  
shown frequently, please make your doctor aware of it.  
A
D
Your palm should face upward.  
• If you move during measurement, the  
movement error symbol ( ) will appear on  
the display. Keep still and repeat the  
measurement.  
B
E
Wrap the wrist cuff around  
your wrist.  
2.  
F
C
Wrap the wrist cuff securely  
around the wrist for taking  
accurate measurements.  
Notes:  
A. Wrist cuff  
B. Battery compartment  
C. Display  
D. Memory ( ) button  
• Wait 2 - 3 minutes before taking another blood  
pressure measurement. Waiting between readings  
allows the arteries to return to the condition prior to  
taking the blood pressure measurement.  
E. Date/Time setting ( ) button  
F. START/STOP button  
• The blood pressure can differ between the right arm  
and the left arm, and therefore also the measured  
blood pressure values can be different. OMRON  
recommends to always use the same arm for  
measurement. If the values between the two arms  
differ substantially, please check with your physician  
which arm to use for your measurement.  
Make sure that the wrist cuff  
does not cover the protruding  
part of the wrist bone (ulna) on  
the outside of the wrist.  
Note: You can take a  
measurement on either  
your left or right wrist.  
Warning:  
Self-diagnosis of measured results and treatment are  
dangerous. Please follow the instructions of your doctor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Convection Oven H 5040 B User Manual
Minolta Digital Camera XK User Manual
Mr Coffee Coffeemaker 115949 User Manual
MTD Trimmer LT31S User Manual
Multiquip Drums AR13D User Manual
Numark Industries DJ Equipment AVM02 User Manual
Onkyo Stereo System SR308 User Manual
Optiquest Computer Monitor Q115 User Manual
Panasonic Camcorder AG AC90A User Manual
Panasonic Digital Camera DMC FZ 28 User Manual