RACKMUX® Series  
RACKMUX-T15-RS16/8  
Rack Mount Console Terminal Drawer with  
Console Switch  
Installation and Operation Manual  
MAN081 Rev Date 2/7/2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
INTRODUCTION.............................................................................................................................................................1  
Console Terminal.........................................................................................................................................................1  
Console Switch............................................................................................................................................................2  
MATERIALS....................................................................................................................................................................3  
FEATURES AND FUNCTIONS ......................................................................................................................................4  
1. INSTALLATION..........................................................................................................................................................5  
1.1 Rack Mounting Instructions ...................................................................................................................................5  
1.2 TERMINAL vs. SERIMUX Cable Connections......................................................................................................6  
1.3 Connect Devices, Hosts, and Power.....................................................................................................................6  
1.4 Connect the SERIMUX and TERMINAL to a Network .........................................................................................7  
1.5 Power Up The RACKMUX.....................................................................................................................................7  
2. GETTING STARTED ..................................................................................................................................................8  
2.1 Setup The TERMINAL...........................................................................................................................................8  
2.1.1 Entering TERMINAL Setup..............................................................................................................................8  
2.1.2 Setup Directory................................................................................................................................................8  
2.1.3 Changing The TERMINAL Operating Parameters ..........................................................................................8  
F2- Genrl SETUP Menu ........................................................................................................................................9  
F4- Comm SETUP Menu.......................................................................................................................................9  
2.1.4 Saving and Exiting Setup.................................................................................................................................9  
2.2 Connect to the SERIMUX......................................................................................................................................9  
3. USING THE SERIMUX CONSOLE SWITCH ...........................................................................................................11  
3.1 Administrator Controls........................................................................................................................................12  
3.1 1 Login as the administrator .............................................................................................................................12  
3.1.2 Port List..........................................................................................................................................................13  
3.1.3 Port Settings ..................................................................................................................................................14  
3.1.3.1 Port serial settings...................................................................................................................................16  
3.1.3.2 Modem settings .......................................................................................................................................18  
3.1.3.3 Port data buffer........................................................................................................................................19  
3.1.4 User List.........................................................................................................................................................20  
3.1.5 User Settings .................................................................................................................................................21  
3.1.5.1 Port access..............................................................................................................................................22  
3.1.5.2 Copy User Settings..................................................................................................................................22  
3.1.6 Advanced Settings.........................................................................................................................................23  
3.1.6.1 Change administrator password..............................................................................................................23  
3.1.6.2 Firmware..................................................................................................................................................24  
3.2. User Controls......................................................................................................................................................26  
3.2.1 User "Accessible host list" screen .................................................................................................................26  
3.2.2 User main menu ............................................................................................................................................27  
3.2.3 Port List screen..............................................................................................................................................28  
3.2.4 User Terse mode...........................................................................................................................................29  
3.2.4.1 Terse mode commands...........................................................................................................................29  
3.2.5 Initialize SERIMUX Console Switch to default settings.................................................................................30  
4. USING THE TERMINAL ...........................................................................................................................................32  
4.1 How To Setup The TERMINAL ...........................................................................................................................32  
4.1.1 Entering TERMINAL Setup............................................................................................................................32  
4.1.2 Saving and Exiting Setup...............................................................................................................................32  
4.1.3 Setup Directory..............................................................................................................................................32  
4.2 Changing The TERMINAL Operating Parameters ..............................................................................................33  
F1- Disp SETUP Menu ..........................................................................................................................................33  
F2- Genrl SETUP Menu..........................................................................................................................................33  
F3- Keybd SETUP Menu ........................................................................................................................................34  
F4- Comm SETUP Menu........................................................................................................................................34  
F5- Misc SETUP Menu...........................................................................................................................................35  
F6-Tabs SET-UP Menu ..........................................................................................................................................35  
ii  
MAN081 Rev Date 2/7/2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F7- FKeys SET-UP Definition Setup Menu ............................................................................................................35  
F8- Ansbk SET-UP Menu .......................................................................................................................................36  
F9- Lan Setup Menu...............................................................................................................................................36  
F10- Colr1 Set-up Menu .........................................................................................................................................36  
F11- Colr2 Set-up Menu .........................................................................................................................................37  
4.3 Local Keyboard Commands ................................................................................................................................40  
4.4 TERMINAL Command Guide ..............................................................................................................................41  
4.4.1 Commands Supported in ASCII Personalities...............................................................................................41  
5.4.2 Variable Values for Table 8 Commands........................................................................................................48  
4.5 ANSI Command Guide.......................................................................................................................................52  
4.5.1 VT100, VT220 and Console ANSI Command Guide ....................................................................................52  
4.5.2 VT52 Command Guide..................................................................................................................................59  
4.6 Using Printer Server via Ethernet Connection.....................................................................................................60  
4.6.1 Basic Setup....................................................................................................................................................60  
4.6.2 Setup for LPD ................................................................................................................................................61  
4.6.3 LPD printing...................................................................................................................................................62  
4.6.4 Setup for TFTP ..............................................................................................................................................62  
4.6.5 TFTP Printing.................................................................................................................................................62  
4.7 On-Screen Display (OSD) ..................................................................................................................................63  
4.7.1 Standard Controls..........................................................................................................................................63  
4.7.2 OSD Control Menu ........................................................................................................................................63  
4.7.2.1 OSD Main Menu......................................................................................................................................63  
4.7.2.2 Brightness/Contrast Menu.......................................................................................................................64  
4.7.2.3 Color Menu..............................................................................................................................................64  
4.7.2.4 Position Menu..........................................................................................................................................64  
4.7.2.5 Setup Menu .............................................................................................................................................65  
4.8 Keyboard Functions.............................................................................................................................................66  
4.8.1 Number Pad...................................................................................................................................................67  
5. HARDWARE INFORMATION...................................................................................................................................68  
5.1 Hardware Specifications: TERMINAL..................................................................................................................68  
5.2 Hardware Specifications: SERIMUX ...................................................................................................................68  
5.3 CPU-to-RACKMUX Ethernet Crossover Cable...................................................................................................69  
5.4 Serial Port Cabling...............................................................................................................................................69  
5.5 Serial Port Pinouts...............................................................................................................................................69  
5.6 Cable Adapters....................................................................................................................................................70  
5.7 SERIMUX Ethernet Pinouts.................................................................................................................................71  
5.8 TERMINAL Connector Pin Assignments.............................................................................................................72  
5.9 Dimensional Drawings.........................................................................................................................................73  
INDEX............................................................................................................................................................................74  
WARRANTY INFORMATION.......................................................................................................................................74  
Download from Www.Somiainiuals.com. All Manuals Search And Download.  
MAN081 Rev Date 2/7/2007  
TABLE OF FIGURES  
Figure 1- Mount RACKMUX to rack...................................................................................................................................................5  
Figure 2- Distinction of connections between TERMINAL and SERIMUX .........................................................................................6  
Figure 3- Connect serial devices, printer, and power supply .............................................................................................................6  
Figure 4- Connect to a Local Area Network (LAN).............................................................................................................................7  
Figure 5- Fields in the Setup menu display which function keys to press for submenus ...................................................................8  
Figure 6- Startup- Accessible host list .............................................................................................................................................10  
Figure 7- Administrator main menu..................................................................................................................................................12  
Figure 8- The Port list displays the status of all ports ......................................................................................................................13  
Figure 9- The Port settings menu ....................................................................................................................................................14  
Figure 10- Control Codes for in-band disconnect sequence............................................................................................................15  
Figure 11- Port serial settings menu ................................................................................................................................................16  
Figure 12- Modem settings menu ....................................................................................................................................................18  
Figure 13- Port data buffer...............................................................................................................................................................19  
Figure 14- User List .........................................................................................................................................................................20  
Figure 15- User settings menu.........................................................................................................................................................21  
Figure 16- Port access list for User 01.............................................................................................................................................22  
Figure 17- Administrator's Advanced settings menu........................................................................................................................23  
Figure 18- Firmware menu...............................................................................................................................................................24  
Figure 19- The SERIMUX is waiting to save its firmware.................................................................................................................25  
Figure 20- A user with limited host port access ...............................................................................................................................26  
Figure 21- User main menu .............................................................................................................................................................27  
Figure 22- A limited user accessible Port list ...................................................................................................................................28  
Figure 23- User port in Terse mode.................................................................................................................................................29  
Figure 24- Location of RESET button..............................................................................................................................................30  
Figure 25- Fields in the Setup menu display which function keys to press for submenus ...............................................................32  
Figure 26- OSD Controls .................................................................................................................................................................63  
Figure 27- Keyboard Layout ............................................................................................................................................................66  
Figure 28- Keys of the Number Pad ................................................................................................................................................67  
List of Tables  
Table 1- Main Setup Menu (F12) Exit Functions................................................................................................................................9  
Table 2- SERIMUX Port Characteristics ..........................................................................................................................................31  
Table 3- Main Setup Menu (F12) Exit Functions..............................................................................................................................32  
Table 4- Programmable Keys ..........................................................................................................................................................36  
Table 5- Color Setup Menu..............................................................................................................................................................37  
Table 6- Color Palettes ....................................................................................................................................................................38  
Table 7- Local Keyboard Commands in Native Mode......................................................................................................................40  
Table 8- Commands Supported in ASCII Personalities ...................................................................................................................41  
Table 9 -Supported VT100,VT220 and Console ANSI Commands .................................................................................................52  
Table 10- VT52 Mode Escape Sequences ......................................................................................................................................59  
Table 11- Number Pad Keys............................................................................................................................................................67  
Download from Www.Somiavnuals.com. All Manuals Search And Download.  
MAN081 Rev Date 2/7/2007  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
INTRODUCTION  
The RACKMUX-T15-RS16 Rackmount Console Terminal Drawer with 16 port Console Switch (RACKMUX) places a VT100/ANSI  
Terminal and a Console Switch right in the rack for space-saving, convenient control of SUN or PC-based headless servers,  
routers, and firewalls. The LCD monitor terminal drawer eliminates the need for an external laptop or table-top dumb terminal.  
The Console Switch delivers control of up to 16 serial devices via Ethernet, LAN or dial-up modem connections. It enables  
unlimited access to remote network management, providing optimum system performance and availability.  
Optional:  
RACKMUX-T15-RS8 Rackmount Console Terminal Drawer with 8 port Console Switch  
Anti-glare protective glass for the LCD- Add G to the model number (i.e. RACKMUX-T15G-RS16)  
RL-T15-TEL- Mounting bracket for 2-post style Telco Rack  
Console Terminal  
The Console Terminal (TERMINAL) is easy to install and configure for either of the following communication modes:  
¾
RS232 Terminal (using an RS-232 port for serial console connection). Use this configuration of the Console Terminal with  
the Console Switch to control multiple servers.  
¾
Telnet Terminal (using an RJ45 10Base-T network port for Ethernet telnet console connection). The Ethernet connection can  
be used with any 10Mb-compatible Ethernet host adapter, but is most suited for use with SUN RSC (Remote System Control)  
Ethernet ports, since these provide the same functionality as serial (ttya) console ports. This connection supports up to 12  
telnet sessions to different servers. The state of each server session is preserved by the terminal. Terminal sessions can be  
switched via hot-keys. When using the Ethernet telnet connection, the Terminal Drawer can be connected to multiple servers  
via an Ethernet switch. However, it is advisable that the network used to connect the server consoles remains private for  
security reasons.  
Note: Both RS232 serial and Ethernet telnet connections cannot be active at the same time.  
The TERMINAL is a general purpose character terminal drawer offering full transaction capabilities and is largely pre-configured  
for most applications. It was designed in conjunction with SUN Microsystems to ensure flawless compatibility with all SUN servers.  
It is also compatible with most racks, including the Sun StorEdge 72", Sun Fire, and most EIA 19" racks. This console drawer is  
the ideal solution for controlling web servers, DNS servers, mail servers and other equipment that lack video card capability, such  
as the SUN Netra systems and HP servers.  
Features  
Entire unit is only 1U (1.75") high.  
High-quality metal construction (ideal for most industrial and commercial settings)  
15" TFT Rack Mount LCD Monitor features a wide viewing angle.  
Screen size: 80x24 characters plus status line.  
Keyboard lock prevents unauthorized use  
800x600 resolution.  
LCD Display controls (using on-screen menu).  
83-key keyboard.  
Supports RSC capabilities.  
Serial and parallel slave-printer ports.  
Includes rack mount kit suitable for SUN and most EIA 19" racks  
Fits 22" to 36" rack depths via adjustable mounting brackets.  
Connects to 10BaseT Ethernet port  
Multiple RS-232 Emulations:  
ADDS A2  
TV1925  
VT52  
VT100  
VT220  
WY-50+  
WY-60  
PC TERM  
PCG Alpha  
Console ANSI  
TVI910+  
WY-100  
WY-120  
WY-325  
Compatibility  
Compatible with any SUN or PC-based headless server.  
Communicates with routers, bridges, firewalls, and hubs  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Console Switch  
The Console Switch (SERIMUX) includes a text-based menu for easy connection management for administrators. Using a  
terminal emulator the menu provides a quick means for user serial connection changes and device control.  
The Console Switch (SERIMUX) is a serial port router that allows links (or connections) between multiple pairs of RS-232  
asynchronous serial ports. The main purpose of the switch is to enable users to manage several serial devices from local or  
remote locations (using external modems). Devices include routers, DSU's, servers, switches or any other equipment allowing  
serial operation using RS232 interface. Users can work locally (using a VT100 or ANSI serial console or a CPU with a terminal  
program (i.e. HyperTerminal)) or from remote locations.  
Each SERIMUX port has to be configured for serial communication (baud rate, parity, etc) within the specifications of the attached  
serial device, but the configurations of the two devices linked by the SERIMUX do not need to match. Various parameters  
(communication speed, hardware and/or software flow control, timeout, etc) can be selected for each SERIMUX port. Devices  
may be either locally connected or connected through attached modems.  
Each SERIMUX port can be configured as either a host or user port. Serial hosts (such as servers, switches etc.) are connected to  
host ports, while serial user devices (such as a terminal or serial console) are connected to user ports.  
The SERIMUX Console Switch supports two operator levels: user and administrator. Users login at user ports and connect to  
serial devices attached at host ports. The administrator (logged in at any user port) and users with administrative privileges can  
see and/or modify various port or user parameters.  
Features  
The SERIMUX provides secure, flexible management of servers, routers, switches, and other networked devices. Key features  
include:  
Eliminates the need to connect each device to an ASCII terminal or PC  
Connect up to 32 devices with different baud rates, parity, and character length. Each switch also has one RJ45  
connector for the local terminal  
Provides out-of-band access to network devices (servers, routers, network switches, and any other network devices  
allowing console operation using RS232)  
No inadvertent "break" signals are generated to cause unintentional rebooting of SUN computers  
Available with an optional 48V DC-DC power converter for telecom environments  
Two operator levels (administrator and user)  
Switching is simplified with programmable device names and menu-driven device selection  
Built-in data buffers save the most RS232 console output from each connected device, which simplifies troubleshooting  
failures  
Local commands can be directed via VT52, VT100, ANSI serial console, a PC with a terminal emulation program, or any  
compliant terminal  
The SERIMUX can be power cycled without halting a SUN host computer  
Gain access to servers without interrupting service to end-users; maintain optimal up-time  
Manage server farms or data centers via serial ports and standard external modems  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
MATERIALS  
Materials Supplied with the NTI RACKMUX-T15-RS16 Rackmount Console Terminal Drawer with Console Switch:  
110-240VAC, 50 or 60Hz-12VDC/4A  
AC Adapter  
DB25M-RJ45F-C  
Modem Adapter  
DB9F-RJ45F  
Serial Adapter  
+
RJ45F-T – DB25M  
Console Adapter  
DB25F- RJ45F  
Console Adapter  
2 Keys for Lock  
CD and Quick Start Guide  
2 rear mounting brackets w/ 4 nuts  
8- #10-32x¾” screws and cage nuts  
Materials Not Supplied, but REQUIRED:  
Serial cable with at least one RJ45 male end for connection to the Console Switch from each device to be connected. See  
Interconnection Cable Wiring Method on page 29 for cable pinout.  
Note: In order to comply with FCC standards, the SERIMUX requires the use of a shielded Category 5 cable connected to  
the Ethernet Interface  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
1
2
3
4
5
6
14  
12  
Fn  
A
1
7
9
10  
8
11  
Front View  
13  
RACKMUX-T15-RS16  
Rear View  
RACKMUX-T15-RS16  
16  
17  
18  
19  
20  
15  
FEATURES AND FUNCTIONS  
1. Power Button- press to turn the LCD monitor ON and OFF  
2. Power LED- indicates operation status  
Green=Power-On, Video Input Signal OK  
Red = Suspend / Stand-by, or no Video Input Signal  
3. Menu Button- press to turn ON the OSD menu  
4. Up Arrow Button- press to move the cursor in the OSD menu up  
5. Down Arrow Button- press to move the cursor in the OSD menu down  
6. Select Button- press to select a menu item (when OSD menu is ON) or press to auto adjust the video quality (when OSD  
menu is OFF)  
7. NumLock LED- illuminates when the number lock is ON  
8. CapsLock LED- illuminates when the keyboard is locked to type all capital letters  
9. Scroll Lock LED- illuminates when the Scroll Lock keyboard feature is ON.  
10. Fn LED- illuminates when the number pad features are enabled.  
11. Keyboard- for manual data entry and computer control  
12. LCD Display- for viewing the video signal from the connected CPU  
13. Key Lock- to secure the keyboard in a closed position preventing unauthorized use  
14. Auto Shut OFF Switch- automatically shuts OFF the LCD display when the monitor is folded down  
15. 12VDC- Power Socket- for connection of 12VDC AC adapter  
16. Ethernet-RJ45 Connector- Ethernet 10/100- for TERMINAL connection to Ethernet  
17. RJ45 Connectors- for attaching CAT5 cables from serial devices  
18. Parallel- Female SUB D 25 connector- for attaching local printer with parallel printer cable  
19. Serial -Male SUB D 9 connector- for attaching a local printer serially  
20. Reset- button to reset SERIMUX to factory default settings  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
1. INSTALLATION  
1.1 Rack Mounting Instructions  
The RACKMUX was designed to be mounted to a rack and includes mounting flanges to make attachment easy.  
1. Determine the mounting height in the rack for the drawer. It should be a height comfortable to use the keyboard and see the  
LCD display. Mark holes in each of the 4 corner cabinet rails at points all level with each other.  
2. Secure the rear brackets to the rear rack cabinet rails at the holes marked in step 1 using #10-32x3/4” screws and cage nuts  
(supplied). Be sure to tighten the screws securely.  
3. Lift the keyboard into position and line the studs on the left and right sides up with the slotted openings in the rear bracket.  
Apply the nuts (supplied) to the studs but do not tighten the nuts yet.  
FYI: There are 5 mounting studs provided on each side of the RACKMUX. Depending on the depth of the rack and  
distance apart of the cabinet rails, the position of the rear bracket may make all 5 studs available for use. In this case,  
apply the 2 nuts to the studs furthest apart from each other on each side.  
4. Slide the drawer in until the top holes in the front bracket flanges line up with the holes marked in step 1. Secure the front  
brackets on the drawer to the front cabinet rails using #10-32x3/4” screws and cage nuts (supplied). Be sure to tighten the  
screws securely. Then tighten the nuts applied in step 3.  
Front Cabinet  
Rail  
Rear Cabinet  
Rail  
Stud on drawer  
Rear bracket overlapping  
drawer  
Front bracket  
flange on drawer  
Drawer  
(Rear edge  
of drawer)  
Rear bracket  
flange  
Secure bracket  
to rail using two  
screws and nuts  
(supplied)  
Secure bracket  
to rail using two  
screws and nuts  
(supplied)  
Apply nuts (supplied) to studs and  
secure rear brackets to drawer.  
Figure 1- Mount RACKMUX to rack  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
1.2 TERMINAL vs. SERIMUX Cable Connections  
The connectors on the rear of the RACKMUX are split between those for the TERMINAL connections, and those for the SERIMUX  
connections (see Fig. 2).  
Rear View of RACKMUX  
Console Terminal  
PARALLEL  
ETHERNE  
SERIAL  
Console Switch  
(SERIMUX)  
RESET  
(TERMINAL)  
16  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
2
1
12VDC  
+
+
+
-
+
Figure 2- Distinction of connections between TERMINAL and SERIMUX  
1.3 Connect Devices, Hosts, and Power  
1. Connect each serial device or host to be connected by the SERIMUX to any port labeled "1" through "16" using a DTE  
or DCE type serial cable. It may be necessary to add one of the cable adapters (supplied) detailed in "Cable Adapters"  
(page 95) between the device port on the serial device or host and the RJ45 connector.  
Note: There are two types of serial devices, data communication equipment (DCE)(i.e. modem) and data terminal  
equipment (DTE) (i.e. CPU), each having different connector pin assignments. The cable adapters (see Materials on  
page 3) make the proper connections.  
2. If connecting a printer, connect either a serial printer cable to the remaining male SUB D 9 connector or a parallel printer  
cable to the female SUB D 25 connector (see Fig. 3).  
3. Connect the 12VDC AC adapter to the power jack labeled "12VDC".  
Attach local printer  
either by serial cable to "Serial"  
or by parallel cable to "Parallel"  
12 VDC  
AC  
ADAPTER  
Rear View of RACKMUX  
PARALLEL  
SERIAL  
ETHERNE  
RESET  
2
16  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
1
12VDC  
+
+
+
+
-
RJ45  
Male  
Connector  
PBX  
ROUTER  
Ethernet cable  
FIREWALL  
SERVER  
Figure 3- Connect serial devices, printer, and power supply  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
1.4 Connect the SERIMUX and TERMINAL to a Network  
To control the SERIMUX and TERMINAL through a network connected PC, connect a CAT5 Ethernet network cable to  
the connector marked "ETHERNET". Then connect the other end of the Ethernet cable to a Local Area Network (LAN)  
through a 10/100 BaseT switch or hub. (See Fig. 4.)  
LAN  
Ethernet cable  
RJ45  
Male  
Connector  
PARALLEL  
SERIAL  
ETHERNE  
RESET  
2
16  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
4
3
1
12VDC  
+
+
+
+
-
Rear View of RACKMUX  
Figure 4- Connect to a Local Area Network (LAN)  
Alternatively, the RACKMUX may be directly connected to PC using a CAT5 Crossover cable. See page 67 for specifications.  
1.5 Power Up The RACKMUX  
1. Connect the AC adapter to a power source.  
2. Using the key, unlock the drawer and slide the keyboard and LCD Display out far enough to raise the display to a comfortable  
viewing angle.  
3. Press the Power button (page 4, item 1) on the LCD monitor.  
4. Adjust the screen's brightness and contrast with the controls located on the LCD monitor– as needed. See page 45 for more  
on OSD controls.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
2. GETTING STARTED  
Introduction  
This chapter covers basic configuration topics. Included is information on setting up the TERMINAL to control the SERIMUX.  
1. Using the instruction under “Setup The Terminal” below (or more detailed instruction on page 31), setup the TERMINAL to  
make connection to the SERIMUX. Configure the terminal as follows:  
Ethernet Mode set to OFF (F4 menu)  
Baud rate at 9600 bps (F4 menu)  
8 bits (F4 menu)  
no parity (F4 menu)  
1 stop bit (F4 menu)  
no flow control (F4 menu)  
ANSI or VT100 terminal mode (F2 menu).  
Within the SERIMUX firmware, the "CONSOLE" port is the internal connection between the TERMINAL and the  
SERIMUX. For consistency, when Port 0 is mentioned within this manual, it refers to the connection made by the  
TERMINAL.  
2.1 Setup The TERMINAL  
To control the SERIMUX some initial settings must be configured in the TERMINAL.  
2.1.1 Entering TERMINAL Setup  
Hold down the <ALT> key and press the <Esc> key to enter Setup mode. When entering Setup, any text on the screen  
temporarily disappears, and the main SETUP directory appears (See Figure 5). When leaving the Setup mode, the main SETUP  
directory disappears, and any text that was on the screen will reappear.  
2.1.2 Setup Directory  
The fields at the bottom of the screen show the various setup menus where the terminal's operating parameters can be changed  
and the function key to press to immediately display any menu.  
Figure 5- Fields in the Setup menu display which function keys to press for submenus  
2.1.3 Changing The TERMINAL Operating Parameters  
To select one of the setup menus shown, press the indicated function key.  
- The screen for that menu appears with the name highlighted.  
- The fields at the middle of the screen indicate the parameters that can be changed in that menu.  
- The top line identifies the keys to press to highlight the parameter fields and change the settings.  
The procedure is: (1) Use arrow key to highlight the parameter field to be changed.  
(2) Use the Spacebar to change the parameter.  
<F12> always returns the user to the top menu.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
The following lists only what is necessary to connect to SERIMUX. For a complete list of features, see page 30.  
F2- Genrl SETUP Menu  
Personality set to Digital Equipment VT-100 or Console ANSI  
F4- Comm SETUP Menu  
Baud Rate set to 9600  
Ethernet Mode set to OFF to set the communication routing by Serial Port.  
Data / Stop Bits set to send and receive 8-bits data with one stop bit  
Xmt Handshake set to None  
Parity set to none  
2.1.4 Saving and Exiting Setup  
The first menu seen when entering Setup serves as a directory to the other Setup menus. To exit Setup or any submenu, press  
<F12>. Pressing <F12> will return the display to the main Setup directory and with another press of <F12> the user will exit  
Setup.  
The highlighted field at the right of the screen gives the user the choice of saving or not saving parameter changes into  
memory before returning the TERMINAL to the normal operating mode. Settings changed will effect the operating environment  
until the TERMINAL is powered-down. Setting changes will only be restored at power-up if they are saved before exiting Setup.  
NOTE: If settings are not saved before exiting Setup, any new selections will be lost when the RACKMUX is powered-  
down.  
To save Setup selections, depress the Spacebar to change the save field at the right side of the screen from NO to YES before  
exiting Setup. (Table 1 describes your options for exiting Setup.)  
Depress <F12> to leave Setup and return to the normal display mode.  
Table 1- Main Setup Menu (F12) Exit Functions  
Option  
Function  
No  
Returns terminal to normal operating mode without saving parameters changes for power up  
Yes  
Saves all changes (operating parameter, tabs, key definition, and answerback message); returns terminal  
To its normal operating mode.  
Shift + Esc  
Restores all setting (operating parameters, tabs, key definitions, and answerback message) to their factory  
default values.  
For changes to the TERMI”NAL settings to take effect, the RACKMUX must be power cycled. Disconnect power from the AC  
adapter and reconnect.  
2.2 Connect to the SERIMUX  
1. Press [ Enter ] on the keyboard to be recognized as the default SERIMUX user. The "Accessible host list" for "User01",  
logged in at "Port00" will be displayed (see Fig 6). By default, all ports are configured as Host ports and all are accessible.  
NOTE: If the user menu does not display re-initialize the SERIMUX following the "Initialize SERIMUX Console Switch to  
default settings" instructions on page 30.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
2. To connect to an attached CPU, enter the number of the port the CPU is connected to and press [Enter].  
Figure 6- Startup- Accessible host list  
Download from Www.Somanuals.com.1A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3. USING THE SERIMUX CONSOLE SWITCH  
The SERIMUX Console Switch is controlled using the TERMINAL and menu-driven integrated software.  
The SERIMUX can be easily configured using the TERMINAL with a keyboard-controlled menu to modify various parameters and  
options for each port to be connected to a device. The administrator menu can be accessed by the administrator for full feature  
control, or the user menu, by any user, for more restricted control of port connections.  
The SERIMUX supports 2 operator levels, administrator and user, each with separate password protection for security.  
The administrator logs in using an administrator password (see next page for login procedure)  
administrator name : ADMINISTRATOR or ROOT (all capital letters)  
default administrator password : NTI (all capital letters)  
The administrator name cannot be  
changed.  
Users login using a password set by the administrator  
FYI: Users may be granted administrative access rights by the administrator.  
To change the administrator  
password, see page 23.  
The administrator and any user with administrative rights is able to:  
view / modify port parameters;  
view / modify user parameters and user access rights to ports;  
disconnect ports, logout users etc.  
Download from Www.Somanuals.com.1A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1 Administrator Controls  
3.1 1 Login as the administrator  
1. The TERMINAL must first be configured (and is typically delivered preconfigured) as described on page 8 under "Getting  
Started”.  
Note: The administrator can only login from the TERMINAL connection (serially). Be sure that the Ethernet Mode is set  
to OFF (page 9) before trying to login as administrator.  
2. Press [ Enter ] on the keyboard and the port will open to the "Accessible host list" for "User01", logged in at "Port00".  
3. Press [Esc] to logout, and [Y] to confirm. A message will be displayed "Disconnecting user now"  
4. Press [Spacebar] or [Enter].  
A prompt requesting a Username will appear.  
5. Enter ADMINISTRATOR or ROOT (all capital letters) and press [Enter]. A prompt for a password will appear.  
6. Enter NTI (all capital letters) and press [Enter]. The Administrator main menu will appear for user ROOT on port 0.  
Note: This will only enter the administrator mode if the administrator password has not yet been changed from "NTI".  
FYI: If SERIMUX is not at initial power-ON, omit steps 2 and 3 above to login.  
Figure 7- Administrator main menu  
FYI: The Administrator main menu will also appear if a user with administrative privileges presses [4] from the User main  
menu.  
From the Administrator main menu, the following options are possible:  
Function  
Description  
Keystroke  
Port List  
Port settings  
Port disconnect  
Display the port list  
View or modify any port settings  
Disconnect any port and logout the user logged in or connected to the port  
[1]  
[2]  
[3] + [port  
number]  
[4]  
User list  
Display the user list  
User settings  
View or modify user settings  
[5]  
User disconnect/logout  
Advanced settings  
Return to user menu  
Logout  
Disconnect and logout any user connected to a port  
View or modify advanced administrative settings (pg 17)  
Leave the administrative menu and return to the User main menu  
Logout from SERIMUX  
[6]  
[7]  
[9]  
[0]  
Download from Www.Somanuals.com.1A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.2 Port List  
From the Administrator main menu, press [1] to display the Port List.  
Figure 8- The Port list displays the status of all ports  
The Port list displays the following information:  
Column Heading  
Description  
Port  
Log  
Con  
Port number and name  
Index number of the user logged in at the port  
The number of another port (Pxx) connected to that port . If the administrator is  
logged in, "Adm" will be displayed  
U/H  
Port type- User or Host  
Mdm  
BaudRate  
Serial  
Modem connection status: Y if modem is connected , - if not  
Port transmitter and receiver speed  
Character size, parity, and stop bit number  
Flow control method- hard (RTS/CTS), soft (Xon/Xoff), both, or none  
Special characters used as soft flow control sequence  
In-band disconnect sequence (1 character, 3 character, or none)  
Remaining time until self-disconnection due to port receiver inactivity (see  
below)  
Flow  
Xon/Xoff  
Discon  
DscTime  
Download from Www.Somanuals.com.1A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
FYI: RE: DscTime ( Disconnect Time)  
The value shown in the Port list is derived from various sources depending on the type of connection active at the time.  
- If a user is logged into a port as just a user, the time shown will be the remaining time based on the user's  
timeout setting.  
- If a user is logged in with administrative privileges and performing administrative tasks, the time will be based  
on the administrator's timeout setting, not based on the user's timeout setting.  
- If two ports are connected to each other, and one port has a lower timeout setting than the other, the lower  
setting will be shown in the DscTime column and control the connection.  
-
-
-
Press [N] to display port information for ports greater than 16, and then [P] to see the previous page.  
Press [R] to refresh the information displayed  
Press [Esc] or [Spacebar] to return to the Administrator main menu  
3.1.3 Port Settings  
From the Administrator main menu, press [2]-[x]-[Enter] where x is the number of the port to display the port settings for.  
Figure 9- The Port settings menu  
Download from Www.Somanuals.com.1A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
From the Port settings menu, the configuration of each port can be viewed and changed.  
Setting  
Description  
Value  
Port name  
Port type  
Change the port name  
Host or User  
Max. 15 characters  
H or U  
In-band disconnect Select characters to use for in-  
1 + code for 1-character sequence (see Fig. 6 below)  
3 + desired characters for 3-character sequence  
sequence  
band disconnect sequence  
0- for no disconnect sequence  
T- display Control code list  
Connection  
Timeout  
Serial settings  
Modem settings  
View port data  
buffer  
Time left before connection will be  
broken due to receiver inactivity  
Display serial settings menu  
Display modem settings menu  
View the last 1016 characters  
received and transmitted to/from  
the port  
0-90 minutes. If 0 is selected, the connection will  
never timeout.  
N/a  
N/a  
N/a  
VT100 displaying  
delay  
Modify the displaying extra delay  
0 = None,1 = normal, 2 = double, or 3 = triple  
"None" value can be used if the display is faster (i.e. with a  
terminal emulator, like HyperTerminal, running on a PC); the  
other values are useful if real terminals or slower serial  
devices are used as user/administrator consoles.  
Reset Port settings Restores factory default port  
to default settings  
A confirmation "Y" will be required  
When [3] is pressed to change the in-band disconnect sequence, the choices provided are 0, 1, 3, or T. Pressing a [T] will bring  
up a Control code list containing key sequences used for 1-character sequences, and the ASCII codes associated with each.  
(See Fig 6) To set a 1-character sequence, press [1], then the code from the table associated with the desired sequence.  
Note: If the 3-character disconnect sequence is enabled, the string: [CR][LF]<3-char sequence>[CR][LF] has to be  
received to break the connection (7 characters). The [CR] and [LF] ASCII characters stand for 13 and 10 decimal codes  
(ASCII Carriage Return and Line Feed) respectively.  
FYI: If the 1-character sequence is  
selected, the connected device will  
not receive the disconnect character.  
If the 3-character sequence is  
selected, it will be sent to the  
connected device, prior to breaking  
the connection.  
Figure 10- Control Codes for in-band disconnect sequence  
-
-
-
-
When selecting each new port setting values, press [Esc] or [Spacebar] to cancel, or press [Enter] to save.  
Press [>] (greater than symbol) to display the current settings for the next port.  
Press [<] (less than symbol) to display the current settings for the previous port  
Press [Esc] or [Spacebar] to return to the "Administrator main menu"  
Download from Www.Somanuals.com.1A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.3.1 Port serial settings  
From the "Port settings" menu, press [5] to display the "Port serial settings" menu. Using this menu, the administrator can adjust  
the serial settings of each port, or copy the current port serial settings and paste them to another port or to all ports.  
Figure 11- Port serial settings menu  
3.1.3.1.1 Baud rate  
Any baud rate (serial speed) between 50 bps - 128Kbps can be selected, (except for port 0, between 300 bps - 115.2 Kbps).  
To modify the port serial speed (baud rate);  
press [1],  
enter the new value or press [T] for a table listing standard baud rates supported,  
and press [Enter]. A confirmation will be required for non-standard baud rate values.  
3.1.3.1.2 Data bit  
The data bit number can be 5, 6, 7, 8, (except for port 0: 7 or 8).  
To modify the data bit number;  
press [2],  
then the bit number: 5, 6, 7, 8  
3.3.1.3 Stop Bit  
The stop bit number can be 1, 2, 1.5 or 2.5, (except for port 0: 1 or 2 stop bits).  
To modify the stop bit number;  
press [3],  
then [1] or [2] or [A] or [B] to select 1, 2, 1.5 or 2.5 stop bits respectively.  
3.1.3.1.4 Parity  
Parity is set by pressing [4], then [N] for none, [E] for even, or [O] for odd.  
3.3.1.5 Flow Control  
The flow control (hand shaking) can be hardware (RTS/CTS or out-band), software (Xon/Xoff or in-band), both or none.  
To select the flow control;  
press [5],  
then [H] or [S] or [B] or [N] respectively.  
Note: If "N" for "none" is selected, data may be lost when sending large (greater than 1000 byte) data packets.  
Note: If a modem is attached to the port, and hardware and/or software flow control is used, the appropriate command  
may be added to the modem initialization string:  
Download from Www.Somanuals.com.1A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Flow control  
Command 1  
Command 2  
None  
RTS/CTS (hardware)  
Xon/Xoff (software)  
Both  
&K3  
&K4  
&K6  
&K0  
\Q3  
\Q1  
disable flow control (not necessary)  
\Q0  
Consult your modem user manual or the modem AT command manual to find the suitable command.  
3.1.3.1.6 Xon or Xoff Characters  
Any non-printable character (ASCII codes between 0 and 31) can be used as flow control Xon or Xoff character. The software flow  
control is transparent, so the special character is not passed to the connected device. If the Xon and Xoff characters are equal, a  
toggle mode is automatically used in the software flow control: whenever the special flow control character is received, the current  
state of flow control is toggled.  
To change the Xon or Xoff character;  
press [6],  
then [0] for Xoff or [1] for Xon,  
enter the new value,  
then press [Enter] to save it, [Esc] or [Space] to cancel.  
FYI: Press [T] after [6] to display a control codes table.  
3.1.3.1.7 DTR line behavior  
If a modem is not attached to the serial port, the DTR port line behavior on port disconnection can be selected as follows: the DTR  
line can be held high (active), low (inactive) or pulsed for 0.5 seconds and then held high. When a modem is attached to the port,  
the DTR line will be pulsed on port disconnection, disregarding this parameter value.  
To modify the DTR line behavior on port disconnection;  
press [8],  
then [H] or [L] or [P] respectively.  
3.1.3.1.8 Inter-character delay  
An inter-character delay (1 - 60 ms) may be defined, each time a character sequence is transmitted from the port. Using this  
command, a minimum pause will appear between transmitted characters; for example, certain types of electro-mechanical devices  
(like teletype equipment) cannot process received characters continuously at their specified baud rate.  
To select an inter-character delay;  
press [8],  
enter the new value (0 for no delay),  
and press [Enter] to save it, [Esc] or [Space] to cancel.  
FYI: This parameter is not available for port 0.  
3.1.3.1.9 Line-break receive or transmit  
It is possible to accept the line-break received from a port, and to send it from the connected port. The break condition (when  
received) is defined as zero data with zero parity and no stop bits.  
To allow or not the line-break receive;  
press [9],  
then [Y] for allowed,  
[Esc] or [Space] to cancel, any other character to deny.  
To define the transmitted line-break extra-duration (this is added to the 1-character transmission time);  
press [0],  
then enter the new value (1 - 999 ms) or 0 to disable it,  
and press [Enter] to save it, [Esc] or [Space] to cancel.  
FYI: These parameters are not available for port 0.  
Download from Www.Somanuals.com.1A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.3.1.10 Copy Port Serial Settings  
Press [+] to select the current port as source in a port settings copy-paste process (except port 0).  
Then, press [*] to paste the port settings.  
Press [Y] to paste the selected port settings to the current port, [A] to paste to all ports, [S] to specify the  
destination port, or press any other key to cancel.  
3.1.3.1.11 Display serial settings for different port number  
Press [>] (greater than symbol) to display the next higher port serial settings, or press [<] (less than symbol) to display the  
previous port serial settings.  
Press [Esc] or [Space] to return to the "Port settings" menu.  
3.1.3.2 Modem settings  
From the "Port settings" menu, press [6] to display the "Modem settings" menu.  
Remote connections are possible if modems are used, usually by the users. The remote modem may call in to a local modem  
attached to a SERIMUX port. A minimum number of port modem settings can be adjusted in the SERIMUX to control the  
connection (try the default values first; refer to the manual(s) for the modems otherwise).  
Figure 12- Modem settings menu  
The administrator can initialize a modem attached to a SERIMUX port, or disconnect the modem. To control the modem  
connection from the "Modem settings" menu, the following functions are possible:  
Function  
Attach and initialize a modem  
Disconnect a modem  
Change the modem reset string  
Change the initialization string  
Change the hangup string  
Enable hangup on "NO CARRIER"  
Save the changes  
Keystroke  
[1] - [A]  
[1] - [D]  
[2]  
[3]  
[4]  
FYI: If an old modem is attached to a SERIMUX port, it may  
be necessary to enable the “Hang-up on “NO CARRIER”  
message” option, in order to hang-up and disconnect the  
attached modem when receiving this message. Press [5],  
then [Y] to enable or any other key to disable this option.  
Usually, this option should remain disabled.  
[5]  
[Enter]  
[Esc]  
[0]-[Y]  
Cancel the command  
Reset to default values  
.
Press [+] to select the current port as source in a port modem settings copy-paste process (except port 0).  
Then, press [*] to paste the port settings.  
Press [Y] to paste the selected port settings to the current port, [A] to paste to all ports, [S] to specify the  
destination port, or press any other key to cancel.  
Download from Www.Somanuals.com.1A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Display modem settings for different port number  
Press [>] (greater than symbol) to display the next port (next higher port index) modem settings, or press [<] (less than symbol) to  
display the previous port modem settings.  
Press [Esc] or [Space] to return to the "Port settings " menu.  
3.1.3.3 Port data buffer  
From the "Port settings" menu, press [7] to view the port data buffer. In this display the administrator can see the last 1016  
characters received and transmitted to/from any port. This way the administrator can verify that data was transferred properly  
between ports.  
Figure 13- Port data buffer  
Press [ P ] to see the previous (older) 128-character page information; press [ N ] to see the next (newer) 128-character page  
information.  
Up to 1016 received characters and 1016 transmitted characters (8 pages) can be inspected, for each port.  
Press [>] (greater than symbol) or [<] (less than symbol) to change the current port.  
Press [Esc] or [Space] to return to the "Port settings " menu.  
FYI: Only the "ROOT" administrator is able to access the port data buffer.  
Download from Www.Somanuals.com.1A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.4 User List  
From the administrator main menu, press [4] to display the User list.  
Figure 14- User List  
Column Heading  
Description  
User  
User Index number  
User Name  
En  
Adm  
Port access  
Log  
Con  
User name associated with the index number  
User status- "Y" = enabled " -" = not enabled  
Displays if user has administrative rights "Y" = yes "-" = no  
Displays what ports the user has access to  
Identifies what port the user is logged into, if any  
Identifies what port the user is connected to (Pxx)  
Or if the user is logged in as an administrator (Adm)  
Or if the user is just logged in (Usr)  
-
-
-
Press [R] to refresh the information and repaint the screen.  
Press [N] to see the next page; press [P] to see the first page.  
Press [Esc] or [Space] to return to the "Administrator main menu".  
Download from Www.Somanuals.com.2A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.5 User Settings  
From the "Administrator main menu", press [5], enter the user index number, then press [Enter].  
The screen will show the current user number and name and the user settings menu:  
Figure 15- User settings menu  
Setting  
Description  
Value  
User name  
Password  
User enabled  
Change the user name  
Define the user password, if any  
Enable or disable user  
Max. 15 characters, use backspace to delete  
Max. 31 characters, use backspace to delete  
Y to enable, any other character to disable  
0-90 minutes 0 = never  
User menu timeout Time interval of user inactivity  
before auto logout of the user will  
occur  
Administrator  
Enable administrative privileges for Y to enable, any other character to disable  
privileges  
user  
Port access  
Define ports user has access to.  
Displays user's Port access list  
(Fig.16)  
1 + port number to grant access to a port  
0 + port number to deny access to a port  
< or > to change to different user access list  
M = User main menu  
User initial screen  
Select the initial user menu to  
H = Accessible host list  
display upon user login  
T = Terse mode  
Reset user settings Restores factory default user  
to default settings  
A confirmation "Y" will be required  
-
-
-
-
When selecting each new user setting values, press [Esc] or [Spacebar] to cancel, or press [Enter] to save.  
Press [>] to display the current settings for the next port.  
Press [<] to display the current settings for the previous port  
Press [Esc] or [Spacebar] to return to the Administrator main menu  
Download from Www.Somanuals.com.2A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Figure 16- Port access list for User 01  
3.1.5.1 Port access  
To quickly grant/deny user access to multiple ports, the use of a dash (-) and/or comma may be used in conjunction with the [1] (to  
grant) or [0] (to deny) command.  
i.e.  
[1] - [1-4,7,9,15] will grant access to ports 1 through 4, 7, 9, and 15, all in one command string  
3.1.5.2 Copy User Settings  
From the User settings menu,  
press [+] to copy the current user's user settings to memory  
press [*] (asterisk) to start the paste function. Three options are available:  
Option  
Description  
Y
A
Sxx  
apply the settings in memory to the current user shown  
apply the user settings in memory to all users  
where xx is 01-16- apply the user settings in memory to a specific user  
The "Y" option is particularly useful if the administrator wants to place a particular user's settings into memory and move around to  
other users (using the [<] or [>] keys) to review their settings before pasting the settings into memory over them.  
The "S" option will allow the administrator to paste settings into memory to a specific user without having to view that user's  
settings list.  
Download from Www.Somanuals.com.2A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.6 Advanced Settings  
From the "Administrator main menu", press [7] to display the “Advanced settings” menu.  
Figure 17- Administrator's Advanced settings menu  
From the "Advanced settings" menu the administrator can perform the following functions:  
Setting  
Description  
Value  
Administrator  
Password  
Define the password to be used by the Max. 31 characters.  
This can only be changed if old password is known.  
administrator  
(If SERIMUX is re-initialized, the password will change  
back to 'NTI")  
0-90 minutes 0 = Never  
the time interval of administrator inactivity,  
prior to logging out.  
Administrator  
Timeout  
Unit name  
User to auto  
login  
Name assigned to the SERIMUX  
User assigned to automatically login at Index number of any enabled user that has access to  
power up without a password.  
Max. 40 characters  
the port being used for the user port  
Connect two  
host ports  
Firmware  
Connect two host ports together  
Enter host port index number, press [Enter], second  
host port index number, and press [Enter] again  
See pg. 24  
Display the firmware menu  
FYI: If at powerup the auto-login user does not have access to port being used, a login by a valid user with  
access rights will be required.  
3.1.6.1 Change administrator password  
For security purposes the administrator should change the factory default administrator password to a unique password. This will  
prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any  
SERIMUX port in buffer mode.  
To change the administrator password, from the Administrator main menu;  
- press [7] to choose Advanced settings and press [Enter]. The Advanced settings menu will appear (Fig. 17)  
- press [1] and a prompt for the old password will appear  
- enter the old password (factory default password is "NTI") and press [Enter]  
- enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered  
in error, and press [Enter]  
- re-enter the password to confirm it, and press [Enter]  
- a message "OK" will appear, press any key to return to the Advanced settings menu  
NOTE: The password entered will be case sensitive so be sure to note what characters are used and what case they are  
in if any are alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.  
NOTE: If the administrator password is not known, the administrator must re-initialize the SERIMUX following the  
"Initialize SERIMUX Console Switch to default settings" instructions on page 26.  
Download from Www.Somanuals.com.2A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.1.6.2 Firmware  
From the Advanced settings menu, press [6] to display the Firmware menu. (From Administrator main menu press [7]-[6])  
Figure 18- Firmware menu  
The Firmware menu has three possible functions:  
Function  
Description  
1. About Firmware  
2. Load new firmware  
Provides information about SERIMUX including revision number, code length, and CRC  
Initiate firmware upgrade (not available at this time)  
3. Save current firmware Save present firmware in SERIMUX to binary file  
3.1.6.2.1 Load new firmware  
To upgrade the firmware that controls the Console Switch, as soon as improved versions become available, download the  
Upgrade" to install it.  
Note: Firmware upgrades are not available as of this publication.  
3.1.6.2.2 Save current firmware  
In order to save the firmware currently in SERIMUX, from the Firmware menu:  
press [3] for Save current firmware. The message shown in Fig.19 will appear.  
Download from Www.Somanuals.com.2A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Figure 19- The SERIMUX is waiting to save its firmware  
Using the terminal program, configured for Xmodem protocol, receive the binary file (for example the HyperTerminal for Windows  
Transfer -> Receive File command) to transfer the SERIMUX firmware to a binary file. When saving the file, choose a directory  
to place the file in and a name that will identify it with the extension " .bin" (i.e. SERIMUX1_8.bin). With the file saved, it can  
be restored to the SERIMUX at any time if desired.  
Download from Www.Somanuals.com.2A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.2. User Controls  
Users can connect only to accessible ports as defined by the administrator. A list of those ports will be displayed with a  
successful login. Connection can be made using the TERMINAL, or a serial terminal with an emulator (e.g. Windows  
HyperTerminal) connected to the SERIMUX at an allowed user port  
To login, press the [Spacebar] or [Enter] key. Users can login by entering a valid name and password, assigned by the  
administrator. When prompted for a "User name:", type the administrator assigned user name and press [Enter]. When prompted  
for the "Password:", type the administrator assigned password and press [Enter].  
Note: User names and passwords are case sensitive. It is important to know what characters must be capitalized and  
what characters must not.  
FYI: The administrator may select a user that will automatically login at power up (User 1 is setup by default). In this  
case, neither name nor password will be required, just press [Spacebar] or [Enter] after power ON the TERMINAL or  
opening the connected terminal emulator.  
After login, the user may connect to an allowed host port, or view host status and parameters. The user is unable to modify port  
parameters unless the user has been granted administrative privileges.  
3.2.1 User "Accessible host list" screen  
After successful login, the "Accessible host list" will be displayed. The administrator may choose another initial screen to be  
displayed, following user's preferences. The Accessible host list includes:  
user index number and name  
index number and name of the login port  
index numbers and names of accessible hosts  
Figure 20- A user with limited host port access  
From the "Accessible host list", the user can perform the following functions:  
Function  
Keystroke  
Connect to host  
Refresh the screen  
Logout  
[xx] - [Enter] (where xx is the port index number)  
[Spacebar]  
[Esc] or [Ctrl]+[X] , then [Y] to confirm  
FYI: The port index numbers are 2-digit decimal numbers. If the wrong number is entered, simply enter the correct  
number. Only the last two numbers entered before the [Enter] key is pressed will be accepted. The [Enter] key  
validates the command; [Esc] or [Spacebar] cancels it.  
Download from Www.Somanuals.com.2A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.2.2 User main menu  
The User main menu includes:  
user index number and name  
index number and name of the login port  
user command list  
Figure 21- User main menu  
From the "User main menu" the following functions are possible:  
Function  
Keystroke  
Connect to host port  
[1]-[xx]-[Enter]  
(where xx is the port index number)  
[2]-[Enter]  
Display Accessible host list  
Display accessible host and user  
ports and info about each  
Login as administrator  
[3]-[Enter]  
[4]-[Enter]  
(only works if user has administrative rights)  
[0] then [Y] to confirm  
Logout  
Refresh the screen  
[Spacebar]  
A user can only connect to the hosts the user has been allowed access to by the administrator. Press [2] to display a list of  
accessible hosts.  
Download from Www.Somanuals.com.2A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.2.3 Port List screen  
From the "User main menu", press [3] to display the list of user accessible ports and information about these ports. Only the  
administrator can change the communication settings.  
Figure 22- A limited user accessible Port list  
On consecutive columns, the following are displayed:  
Column  
Description  
Port  
index number of the port  
Name assigned to the port  
Port type, user or host  
Yes if modem is attached, - if not  
Receiving and transmitting speed of the port  
Character size, parity, and stop bit number  
Defines flow control method  
Hard (RTS/CTS or outband)  
Soft (Xon/Xoff or inband)  
Both  
Press [R] to refresh and re-display the  
information on the screen.  
Port Name  
Usr/Hst  
Modem  
BaudRate  
Serial  
If the number of user accessible ports is  
greater than 17,  
press [N] to see the next page,  
press [P] to see the first page.  
Flow  
Press [Esc] or [Space] to return to the  
"User main menu".  
None  
Xon/Xoff  
Discon  
Characters used for Xon and Xoff flow control  
In-band disconnect sequence (1-3 characters, or none)  
Download from Www.Somanuals.com.2A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
3.2.4 User Terse mode  
This mode is especially useful when the SERIMUX is directly controlled by external software from a serial console (as a user  
without administrative privileges), rather than being controlled by a user from a keyboard interface.  
Entering short command strings performs functions similar to the user main menu commands. A [CR] – [LF] sequence ends every  
string. The commands are not echoed; the SERIMUX returns to the serial console a specific answer if the command is  
successfully accomplished or an error message otherwise.  
Terse mode can be used only if the administrator configures a user port to enter into Terse mode at login. If a keyboard-based  
user logs into a port intended for Terse mode operation, the following image will appear:  
Figure 23- User port in Terse mode  
From Terse mode, a limited number of functions are possible;  
3.2.4.1 Terse mode commands  
¾
Connect to port  
Send or type in:  
[C] xx [Enter]  
where xx is the port index number. The answer will be:  
OK [CR][LF][LF][FF]  
If an error occurs (i.e. the port is not accessible), the answer will be:  
Err [CR][LF]  
¾
Accessible host list  
Send or type in:  
[H] [Enter]  
The answer may be, for example:  
02,03,04,05,06,07,08,09,10,11,12,13,14,15,16 [CR][LF]  
(the accessible hosts, separated by commas)  
¾
Port info  
Send or type in:  
[P] xx [Enter]  
where xx is the accessible port index number. The answer may be, for example:  
04,H, 9600,8N1 ,N,QS,1X [CR][LF]  
where the comma separated fields stand for:  
- port index number;  
- port type: U or H for User or Host;  
- port baud rate;  
- data bits (5..7), parity (N, E, O for None, Even, Odd), stop bits (1, 1.5, 2, 2.5);  
- flow control (N, H, S, B for None, Hard, Soft, Both respectively);  
- in-band (soft) flow control Xon and Xoff characters (in this example Xon = [Ctrl+Q] and Xoff = [Ctrl+S]);  
- disconnect sequence length and sequence (i.e. “0 ” for none, “1X ” for 1-char [Ctrl+X] sequence, “3```” for 3-char ```  
sequence);  
If the port is not accessible to the user, the answer will be:  
Err [CR][LF]  
Download from Www.Somanuals.com.2A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
¾
Verbose mode  
Send or type in:  
[V] [Enter]  
The answer will be:  
OK [CR][LF]  
and the Terse mode will be terminated. The “Accessible host list” or the “User main menu” will be displayed.  
Note: Once a user configured for Terse mode login exits Terse mode to enter Verbose mode, Terse mode login will no  
longer be available at login. To return to Terse mode, the administrator must re-configure the user settings to enter  
Terse mode at login.  
¾
User Logout  
Send or type in:  
[L] [Enter]  
The answer will be:  
OK [CR][LF]  
With the next login of the same user, Terse mode will resume.  
FYI: Buttons pressed in sequence on the keypad to enter commands must be pressed within 5 seconds of each other for  
the SERIMUX to respond. Otherwise, the sequence will need to be repeated from the beginning.  
¾
Login the administrator  
Note: In order to login the administrator to a port other than port 0, the administrator must first configure the desired  
port as a user port (see page 15). By default, all ports, other than 0, are configured as host ports.  
3.2.5 Initialize SERIMUX Console Switch to default settings  
SERIMUX can be reset to default settings by using the "RESET" button  
The RACKMUX should be OFF before pressing the "RESET" button.  
1. Press and hold the "RESET" button using a small object that will fit through the hole in the back of the SERIMUX. (See Fig.  
21).  
2. Turn ON the RACKMUX.  
3. Wait 3 seconds.  
4. Release the button.  
Factory reset button  
Rear View of RACKMUX  
ETHERNET  
PARALLEL  
SERIAL  
12VDC  
5A  
-
+
16  
15  
14  
13  
12  
11  
10  
9
8
7
6
5
3
2
1
4
R
NETWORK  
TECHNOLOGIES  
INCORPORATED  
NTI  
1275 Danner Dr Tel:330-562-7070  
Aurora, OH 44202 Fax:330-562-1999  
www.networktechinc.com  
Figure 24- Location of RESET button  
Caution: During initialization, the customer modified parameter values will be replaced with the factory default values  
(for default values, see Table 2, page 31), user names and passwords will be erased.  
Download from Www.Somanuals.com.3A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Every port is defined through the following parameters:  
Table 2- SERIMUX Port Characteristics  
Description  
Acceptable Value  
Default Value  
Number  
0-8/16/24/32  
Same (not changeable)  
Name  
Up to 15 characters  
“Port00” to “Port32”  
Type – port 0  
User  
User (not changeable)  
Type – except port 0  
Baud rate – port 0  
Baud rate – except port 0  
Data bits per character – port 0  
Data bits per character – except port 0  
Stop bits – port 0  
User or Host  
300-115200  
50-128000  
7,8  
5,6,7,8  
1, 2  
Host  
9600  
9600  
8
8
1
Stop bits – except port 0  
Parity  
Handshake mode (flow control)  
1, 1-1/2, 2, 2-1/2  
No parity, even, odd  
Xon / Xoff (or in-band, or software),  
RTS/CTS (or out-band or hardware),  
Both,  
1
No parity  
None  
None  
Xon character  
Xoff character  
Inter-character delay – except port 0  
(no delay allowed on port 0)  
any ASCII nonprintable character (0-31 range)  
any ASCII nonprintable character (0-31 range)  
1-60 milliseconds, none  
Ctrl+Q (17)  
Ctrl+S (19)  
None  
Line break receive allowance – except port 0 Yes or No  
(no allowance for port 0)  
No  
Transmitted line break extra duration (added  
to 1 character transmission time) – except  
port 0 (no extra duration for port 0)  
In-band disconnect sequence  
No break transmitted, 1-999 milliseconds  
No break transmitted  
0 (disabled), 1, or 3 characters sequence  
1-char sequence  
1 character disconnect sequence  
3 character disconnect sequence  
Connection timeout  
Any ASCII nonprintable character (0-31 range)  
Any 3 ASCII characters  
1-90 minutes, never  
Low, high, or pulsed for 0.5 seconds and then held  
high  
Ctrl+X (24)  
``` (3 back quotes)  
15 minutes  
High  
DTR output upon disconnect  
Modem Reset string  
Up to 41 characters  
ATZ  
Modem Initialization string  
Modem Disconnect string  
Up to 41 characters  
Up to 41 characters  
AT&F&C1&D2S0=0  
ATH  
Download from Www.Somanuals.com.3A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4. USING THE TERMINAL  
4.1 How To Setup The TERMINAL  
The TERMINAL is compatible with most CPUs and application packages. A menu driven setup system is provided to select and  
save the settings required by the CPU and application. To control the CPU, or in this case the SERIMUX, a user must be  
familiar with the requirements of the SERIMUX in order to setup the TERMINAL.  
4.1.1 Entering TERMINAL Setup  
Hold down the <ALT> key and then depress the <Esc> key to enter Setup mode. When entering Setup, any text on the screen  
temporarily disappears, and the main SETUP directory appears (See Figure 25). When leaving the Setup mode, the main SETUP  
directory disappears, and any text that was on the screen will reappear.  
4.1.2 Saving and Exiting Setup  
The first menu seen when entering Setup serves as a directory to the other Setup menus. To exit Setup or any submenu, press  
<F12>. Pressing <F12> will return the display to the main Setup directory and with another press of <F12> the user will exit  
Setup.  
The highlighted field at the right of the screen gives the user the choice of saving or not saving parameter changes into  
memory before returning the terminal to the normal operating mode. Settings changed will effect the operating environment until  
the TERMINAL is powered-down. Setting changes will only be restored at power-up if they are saved before exiting Setup.  
NOTE: If settings are not saved before exiting Setup, any new selections will be lost when the RACKMUX is powered-  
down.  
To save Setup selections, depress the Spacebar to change the save field at the right side of the screen from NO to YES before  
exiting Setup. (Table 3 describes your options for exiting Setup.)  
Depress <F12> to leave Setup and return to the normal display mode.  
Table 3- Main Setup Menu (F12) Exit Functions  
Option  
Function  
No  
Returns terminal to normal operating mode without saving parameters changes for power up  
Yes  
Saves all changes (operating parameter, tabs, key definition, and answerback message); returns terminal  
To its normal operating mode.  
Shift + Esc  
Restores all setting (operating parameters, tabs, key definitions, and answerback message) to their factory  
default values.  
4.1.3 Setup Directory  
The fields at the bottom of the screen show the various setup menus where the terminal's operating parameters can be changed  
and the function key to press to immediately display any menu.  
Figure 25- Fields in the Setup menu display which function keys to press for submenus  
Download from Www.Somanuals.com.3A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.2 Changing The TERMINAL Operating Parameters  
To select one of the setup menus shown, press the indicated function key.  
- The screen for that menu appears with the name highlighted.  
- The fields at the middle of the screen indicate the parameters that can be changed in that menu.  
- The top line identifies the keys to press to highlight the parameter fields and change the settings.  
The procedure is: (1) Use arrow key to highlight the parameter field to be changed.  
(2) Use the Spacebar to change the parameter.  
<F12> always returns the user to the top menu.  
The following tables list the parameters for each menu and explain their settings. Default settings are listed first  
unless otherwise noted.  
F1- Disp SETUP Menu  
Columns sets the screen display for 80 columns, 132 columns, or Econ-80 (80 columns with more pages of memory).  
Lines sets the screen display for 24, 25, 42, or 43 lines. (24 lines are normally required for VT emulation, 25 lines for PC Term.)  
Auto Page on causes a new page of memory to move onto the screen when the cursor reaches the top or bottom of the page.  
Display CRT/LCD selects which kind of monitor be used. If LCD monitor is selected, the display columns only support 80  
columns on Econ-80 columns. Must be set to LCD.  
Cursor sets the cursor display to blink or steady, block or underline.  
Background sets the screen display to Dark (light chars. on a dark background) or Light (dark chars. on a light background).  
Width Change Clear causes the terminal to clear the screen when executing a command to change the number of columns.  
Screen Saver OFF, 1, 2, 3, 4, 5, 6. Sets the screen saver to activate after the specified number of minutes.  
Page Length sets the length of a page of display memory to:  
1 x Lines: Equal to the number of lines selected in the lines parameter (this value must be set when using multiple  
sessions)  
2 x Lines: Two times the value of the lines parameter  
4 x Lines: Four times the value of the lines parameter, or  
*: Equal to the value of the lines parameter, with a second page containing the rest of the lines remaining in memory.  
ANSI Reverse OFF/ON. Control function ANSI, VT-100 and VT-220:  
"OFFf" means, when SGR command ESC [ 3? m and ESC [ 4? m select background and foreground color change  
respectively.  
"ON" means, when SGR command ESC [ 3? m and ESC [ 4? m select foreground and background color change  
respectively. (?  
can be 0,1,2,...,7)  
F2- Genrl SETUP Menu  
Personality sets the terminal's operating mode to Wyse 325, Wyse 120/Wyse 60 (native mode), Wyse 50+ (WY-50, WY-50+,  
WY-100, ADM 31/5/3a), TeleVideo TVI 925, TVI910+ (includes 910), ADDS A2, Digital Equipment VT-100, VT-220 7 bits,  
VT-220 8 bits, VT-52, Console ANSI, PC TERM, PCG Alpha.  
Scroll Speed sets the display scroll rate to Jump (the rate data is received), Smooth-8 (eight lines per second), Smooth-4,  
Smooth-2, or Smooth-1.  
Rcvd CR causes the cursor to move to the beginning of the current line (CR) or the beginning of the next line (CRLF) when the  
terminal receives an ASCII CR.  
Enhance allows the terminal to recognize an enhanced set of codes when the terminal is not in the native personality.  
Auto Scroll causes the data to scroll up a line when the cursor moves past the last line of the page.  
Download from Www.Somanuals.com.3A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Monitor causes the terminal to display symbols for escape sequences and control codes without acting on them (test feature).  
Status Line sets the top line of the screen as the status line.  
End of Line Wrap causes the cursor to move to the start of the next line when additional characters are entered at the end of a  
line.  
Attribute sets display attributes to be assigned to each character as it is entered (Char), to be active to the end of the line (Line),  
or to be active to the end of the page (Page).  
F3- Keybd SETUP Menu  
Keyclick sets the terminal to sound a muted beep each time a key is pressed or repeated.  
Margin Bell sets the terminal's bell to ring when the cursor reaches the column where the bell is set (default is column 72 in 80-  
column mode or 124 in 132-column mode).  
NRC ON/OFF determines the communication and keyboard national character set.  
DEL Keypad Dot/Del or Comma/Del. Determines whether numlock DEL generates dot or comma.  
Key Repeat OFF, 1, .... ,8. Defines key repeat rate after a key has been depressed for about 1/2 second.  
Language sets correct terminal operation for the language of the keyboard connected to it: US, UK, Danish, German, Spanish,  
Swedish, Norwegian, Italian, French, Belgian, Swiss/French, and Swiss/German. Should be set to US.  
Bell Volume OFF, 1, 2, 3 (3 different volumes)  
Limit Xmt causes the terminal to send data through the HOST port as fast as the baud rate allows (None), or at a maximum rate  
of 60 cps or 150 cps. In older systems limiting character rate is necessary to prevent loss of data.  
Key Code sets the terminal to send normal ASCII characters (ASCII) or PC-type scan codes for every key up / down (Scan).  
Scan is only required for the PC Term personality.  
Num Start ON/OFF. When the terminal powers ON, this field determines whether the numeric pad starts as Numeric (NUM ON)  
or Function (NUM OFF).  
F4- Comm SETUP Menu  
Baud Rate sets the host port baud rate to 50, 110, 134.5, 200, 300, 600, 1200, 2400, 4800, 7200, 9600, 19200, 38400, 57600,  
76800, or 115200.  
Rcv Hndshake allows the terminal to control the receipt of data from a device connected to the SERIAL1 port with no  
handshaking (None), Xon / Xoff handshaking, DTR handshaking, DTR / Xoff handshaking  
XPC Hndshake ON/OFF to set XPC code handshake, only possible when the personality parameter is set to PC Term.  
Ethernet Mode ON/OFF to set the communication routing by Ethernet Network / or Serial Port.  
Data / Stop Bits through the SERIAL1 port, the terminal to send and receive 8-bits data with one stop bit or two stop bits, or 7-  
bits data with one stop or two stops bits.  
Xmt Handshake causes the terminal, when sending data to a device connected to the SERIAL1 port, to ignore all incoming  
software handshaking signals (None) or to control data output in responds to Xon/Xoff handshaking.  
Printer  
Parallel : sends data to a parallel printer connected to the parallel port.  
Serial : sends data to a serial printer connected to the serial 2 port.  
OFF : ignores the print command.  
Auto Connect OFF/ON selects whether a return character is required to establish an Ethernet connection.  
Parity sets the terminal send data to the SERIAL1 port with none, odd, mark, even, or space parity.  
Comm Mode sets the SERIAL1 port communication mode to full duplex (FDX), block (BLK), half duplex (HDX), or half duplex  
block (HBLK).  
Download from Www.Somanuals.com.3A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Multiple Sessions defines whether an Ethernet connection supports multiple sessions function.  
ON : indicates the terminal supports multiple sessions. Each session only has one display page. In 80 or 132 column mode, 8  
simultaneous sessions are supported. In Econ-80 column mode, 12 simultaneous sessions are supported.  
OFF : indicates the terminal only has single session. In this mode page length greater than one page can be defined.  
F5- Misc SETUP Menu  
Wprt Intensity sets the write protect attribute: normal, blank, dim, blank/dim.  
Block End causes the terminal to send a block of data to the CPU with a line terminator as an ASCII US character and block  
terminator as an ASCII CR character (US / CR), or with line terminators as ASCII CR and LF characters and the block terminator  
as an ASCII ETX character (CRLF / ETX).  
Ptr Parity causes the terminal to send the data to the SERIAL 2 (printer) port with none, odd, mark, even, or space parity.  
Printer RCV ON/OFF  
Wprt Reverse sets the write-protected characters to appear in reverse (dark characters on a light background).  
Ptr Baud rate sets the SERIAL 2 (printer) port baud rate to 75, 150, 300, 600, 1200, 2400, 4800, 7200, 9600, 19200, 38400,  
57600, 76800, 115200, 230400, 460800.  
Ptr Rcv Hndshake sets the printer receive handshake through SERIAL 2 to be none, DTR, Xon / Xoff, DTR/Xoff .  
Wprt Underline sets the write-protected characters to appear underlined.  
Ptr Data/Stop Bits sets the data and stop bits through the SERIAL 2 (printer) port.  
Ptr Xmt Hndshake sets the printer handshake to be none, DSR, Xon / Xoff, or Both .  
F6-Tabs SET-UP Menu  
On the tabs setup menu screen, the terminal's current tab stops are indicated by uppercase T's displayed along a line of periods  
that mark each column position.  
(1) A tab stop in columns 2 through 78 is shown as a T in the upper line of periods  
(2) A tab stop in columns 79 through 132 is shown as a T in the lower line of periods  
The user can easily determine where tabs are set by moving the cursor across the line and reading the column number displayed  
on the right side of the screen. Clear and set tabs anywhere on the line, as follows:  
(1) To move the cursor across the line, press < > (right arrow) or <> (left arrow)  
(2) To either clear or set (toggle) an individual tab stop at the cursor position, press <Spacebar>  
(3) To clear all tabs, press <Home>  
(4) To set tabs to the default setting (every eighth column), press <Backspace>  
Note: A tab stop cannot be set to column 1.  
F7- FKeys SET-UP Definition Setup Menu  
The function keys and many of the editing keys can be redefined to send a unique character string of up to 64 characters. Keys  
that are not programmed will send a default sequence, which is determined by the personality selected. Table 4 lists the  
programmable keys.  
To redefine a key:  
1. Select the key to be redefined by pressing that key together with <Ctrl>. This highlights the key's definition field.  
2. Press < > (up arrow) to select the shifted or unshifted key definition field.  
3. Enter the key definition (up to 62 characters) at the cursor position. Correct errors by pressing <  
> (left arrow) to  
delete characters or <Home> to clear the definition.  
4. If the user wants to change the key's direction, press <Enter> (on the numeric pad) until the desired choice appears.  
Direction determines where the key data is transmitted:  
- Remote: Sends data to the CPU only, regardless of the terminal's communication mode. (Until redefined, the  
direction of all the programmable keys is remote.)  
- Local: Sends data to the terminal only, regardless of the terminal's communication mode  
- Normal: Sends data to the CPU and / or the terminal, depending on the terminal's communication mode  
Download from Www.Somanuals.com.3A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 4- Programmable Keys  
Enhanced PC-Style Keyboard  
F1 through F12  
Enhanced PC-Style Keyboard  
ENTER (Both ENTER keys are programmable)  
ESCAPE  
(UP ARROW)  
(DOWN ARROW)  
HOME  
(LEFT ARROW)  
(RIGHT ARROW)  
BACKSPACE  
DELETE  
INSERT  
PAGE DOWN  
PAGE UP  
PRINT SCREEN  
TAB  
END  
F8- Ansbk SET-UP Menu  
A message of up to 20 characters can be programmed to identify the terminal to the CPU. Enter the message at the cursor  
position. Correct errors by pressing < > (left arrow) to delete characters or <Home> to clear the message.  
CONCEAL hides the answerback message, so it is not displayed in setup mode.  
To save the message in nonvolatile memory, exit Setup mode with the YES option.  
F9- Lan Setup Menu  
This menu configures the terminal for Ethernet communication. Use of Ethernet communications provides the additional ability to  
open multiple sessions (applications) on one or more CPUs/servers at the same time. Support of these extended features requires  
the server to be configured to accept telnet connections.  
Note: The Ethernet option in the F4 setup menu must be set to ON for the terminal to work in an Ethernet environment.  
Local IP Address is the IP address assigned to this terminal. This must be a unique IP address. An example of this address is  
200.200.200.10.  
Netmask is a value generated by the system based on the IP address. The system administrator would have this information. An  
example is 255.255.255.0  
Gateway This IP address is used to communicate with other networks. If a gateway is not being used this option should be blank.  
Remote IP 0...B Address are for any remote CPU, or devices, that the terminal will communicate with for a specific session.  
These twelve remote IP addresses should all be identical if all communications will be with only one CPU. If Multiple sessions-ON  
in the F4 menu has been selected, and there is more than one CPU on the system, the user must specify which CPU each  
session will communicate with. To communicate with a different CPU for a future session, these settings must be changed.  
Note 1: The Multiple session option allows 8 separate sessions if any emulation other than ECON-80 is selected. If  
ECON-80 emulation is selected, the Multiple session option will then allows 12 separate sessions.  
Note 2: Port 23 Is the telnet service by default.  
Note 3: The terminal must be powered cycled after saving for these parameters to take effect.  
Term Type allows definition of the terminal with up to 40 characters. If Term Type is empty the default type is sent to the CPU  
by the system.  
Ethernet Node ID displays the serial number of the hardware Ethernet interface device. This is a default value of the  
manufacturer of the hardware device and should not be changed.  
F10- Colr1 Set-up Menu  
Selects the color palette to be used for each screen attribute. A text sample of the selected colored is displayed next to each  
selection. Attribute selections are listed below.  
Normal  
Undl.  
Dim  
Undl. Blank  
Blank  
Undl. Blink  
Blink  
Blink Blank  
Rev  
Rev Blank  
Rev Blink  
Rev Blink Blank  
Undl. Blink Blank  
Undl. Rev  
Undl. Rev Blank  
Undl. Rev Blink  
Undl. Rev Blink Blank  
Download from Www.Somanuals.com.3A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
F11- Colr2 Set-up Menu  
The color functionality differs with emulation. In general VT100, VT220 and ANSI Console work with applications, which control  
the color directly. The remaining personalities associate colors based on existing monochrome video attributes. This section will  
define parameter selection based on personality selected.  
Background = Will determine the color of the background screen under some conditions (16 colors).  
Normal F.G. \ Normal B.G. = These fields allow the user to select the character and background color (16 colors) for data  
entered on the display before the application defines the color display remotely.  
Border Color = The color of the border around the edge of the screen.  
Cursor = Will select the color of the cursor (16 colors).  
Intensity F.G. \ Intensity B.G. = These fields allow the user to select the character and background color (16 colors) for  
data entered on the display as Dim in ASCII emulation's and Bold in VT\ANSI emulation's before the application defines the color  
display remotely.  
Attribute = Bold/Blink  
Color mode = Is automatically selected based on the emulation selected.  
Color map = Applies in WY325 mode only and determines if the monochrome attribute Reverse or Blank will be used to map  
monochrome attributes to color.  
Color Association = OFF/ON  
Table 5- Color Setup Menu  
Option  
ASCII (NOT WY325)  
WY325 *  
VTXXX  
ANSI CONSOLE  
Background =  
The whole data area of the  
screen will be displayed in this  
color, when the application  
hasn't entered character or  
spaces with the Normal or  
Intensity B.G. color. Changes  
in Background color will  
affect Normal and Intensity  
B.G. Any clear screen  
No Function  
Same as ASCII  
Same as ASCII  
commands will clear to this  
color.  
Cursor =  
Normal F.G. =  
Selects Cursor color  
Selects color of Normal F.G.  
Selects Cursor color  
No Function  
Selects Cursor color  
Initial color selection  
at power up  
Selects Cursor color  
Initial color selection  
at power up  
Normal B.G. =  
Intensity F.G. =  
Intensity B.G. =  
Selects color of Normal B.G.  
Selects color of Intensity F.G.  
Selects color of Intensity B.G.  
Automatic  
No Function  
No Function  
No Function  
Automatic  
Initial color selection  
at power up  
Initial color selection  
at power up  
Initial color selection  
at power up  
Automatic  
Initial color selection  
at power up  
Initial color selection  
at power up  
Initial color selection  
at power up  
Automatic  
Color Mode =  
Normal/Palette  
Color Map =  
No Function  
See Above  
No Function  
No Function  
* When the WY 325 personality is selected holding the Ctrl key down and depressing either the 0, 1, ..., 9 or (.) period keys in  
the numeric pad change the assignment of color on the screen. Each selection is called a palette and is described in Table 6.  
Download from Www.Somanuals.com.3A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 6- Color Palettes  
Palette  
Display Attribute  
Foreground Color  
Background Color  
0
Normal  
Green  
Black  
Reverse (or blank)*1  
Intensity*2  
Black  
Blue  
Yellow  
Black  
Blue  
Black  
Cyan  
Black  
Red  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse(or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Black  
Cyan  
Black  
Red  
Black  
Green  
Black  
Yellow  
Black  
Cyan  
Black  
White  
Black  
Cyan  
Black  
Red  
1
2
3
4
5
Black  
Red  
Reverse (or blank)*1  
Black  
Yellow  
Black  
Cyan  
Black  
White  
Black  
White  
Black  
Red  
Intensity*2  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Reverse (or blank)*1  
Intensity*2  
Black  
Magenta  
Black  
Blue  
Intensity*2 and reverse (or blank)*1  
Underline  
Black  
Magenta  
Black  
Blue  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Black  
Cyan  
Black  
White  
Black  
Magenta  
Black  
Yellow  
Black  
Magenta  
Black  
Blue  
Black  
Blue  
Reverse (or blank)*1  
Black  
White  
Black  
Magenta  
Black  
Yellow  
Black  
Cyan  
Black  
Blue  
Intensity*2  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Reverse (or blank)*1  
Intensity*2  
Black  
Green  
Black  
Red  
Intensity*2 and reverse (or blank)*1  
Underline  
Black  
Green  
Black  
Red  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Black  
Magenta  
Black  
White  
Black  
Green  
Black  
Cyan  
Black  
Yellow  
Black  
White  
Black  
Green  
Black  
Black  
Cyan  
Reverse (or blank)*1  
Intensity*2  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Download from Www.Somanuals.com.3A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 6- Color Palettes (Cont'd)  
Palette  
Display Attribute  
Foreground Color  
Background Color  
6
Normal  
Yellow  
Black  
Reverse (or blank)*1  
Intensity*2  
Black  
Red  
Yellow  
Black  
Red  
Black  
Cyan  
Black  
Magenta  
Black  
Red  
Intensity*2 and reverse (or blank)*1  
Underline  
Black  
Cyan  
Black  
Magenta  
Black  
Red  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
7
8
9
Reverse (or blank)*1  
Yellow  
Magenta  
Black  
Cyan  
Black  
Green  
Black  
White  
Black  
Red  
Black  
Yellow  
Black  
Magenta  
Black  
White  
Black  
Yellow  
Black  
Blue  
Black  
Magenta  
Black  
Cyan  
Black  
Green  
Black  
White  
Black  
Red  
Intensity*2  
Intensity*2 and reverse (or blank) *1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank) *1  
Normal  
Reverse (or blank)*1  
Intensity*2  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Underline, intensity, *2 and reverse (or blank)*1  
Normal  
Black  
Yellow  
Black  
Magenta  
Black  
White  
Black  
Yellow  
Black  
Blue  
Reverse (or blank)*1  
Intensity*2  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Black  
Cyan  
Black  
Green  
Black  
Blue  
Black  
Cyan  
Black  
Yellow  
Black  
Blue  
Underline, intensity, *2 and reverse (or blank)*1  
10 (Soft Palette) Normal  
(soft Reverse (or blank)*1  
palette) Intensity*2  
Black  
Cyan  
Black  
Red  
Intensity*2 and reverse (or blank)*1  
Underline  
Underline and reverse (or blank)*1  
Underline and intensity*2,*3  
Black  
Cyan  
Black  
Red  
Underline, intensity, *2 and reverse (or blank)*1  
Black  
*1. Whether the reverse or blank attribute is mapped to the colors shown depends on an escape sequence or the setting of  
the Color Map setup parameter on the Attribute menu. The default is reverse. When the blank attribute is mapped, only the  
background is visible.  
*2. The intensity is dim in ASCII personalities and bold in ANSI personalities. (The intensity attribute is not supported in  
the following personalities: Wyse 50+, ADDS A2, TVI 910+, TVI925, and VT52.) The attribute can be disabled by  
an escape sequence or in setup mode (Intensity Attribute parameter).  
*3. In each palette, the status line displays the same foreground and background colors as shown here for the underline-and-  
intensity attribute.  
Download from Www.Somanuals.com.3A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.3 Local Keyboard Commands  
Table 7 lists local keyboard commands in the terminal's native mode.  
Table 7- Local Keyboard Commands in Native Mode  
Key Sequence by keyboard Style  
Command  
Enhanced PC  
Toggle CAPS LOCK on/off  
Toggle NUM LOCK on/off  
Put terminal in SETUP mode  
Partially reset terminal, including communication unlock  
keyboard, turn off all print modes  
CAPS LOCK  
NUM LOCK  
ALT ESC  
ALT PAUSE  
Send break*1  
BREAK*2  
Toggle between block and full-duplex modes  
Print Screen formatted  
SHIFT BREAK  
PRINT SCREEN  
Turn auxiliary print mode on/off  
SHIFT SYS REQ*3  
CTRL SHIFT 1 (kpd)  
CTRL  
CTRL SHIFT  
CTRL SHIFT  
CTRL SHIFT HOME  
CTRL 0kpd  
Turn monitor mode on/off  
Turn status line display on/off  
Speed scrolling rate  
Slow scrolling rate  
Home cursor and clear page  
Display page 0  
Display page 1  
CTRL 1kpd  
PAGE DOWN  
Display next page (or active other window) *4  
PAGE UP  
Display previous page (or active other window) *5  
Toggle between split screen*5 and full screen format  
CTRL SHIFT –kpd  
ALT F1  
Toggle Session 0*6  
ALT F2  
Toggle Session 1*6  
ALT F3  
Toggle Session 2*6  
ALT F4  
Toggle Session 3*6  
ALT F5  
Toggle Session 4*6  
ALT F6  
Toggle Session 5*6  
ALT F7  
Toggle Session 6*6  
ALT F8  
Toggle Session 7*6  
ALT F9  
Toggle Session 8*6  
ALT F10  
ALT F11  
ALT F12  
CTRL SHIFT. Kpd  
Toggle Session 9*6  
Toggle Session A*6  
Toggle Session B*6  
Close the active Session by Local Terminal*6  
*1. To MODEM port only when configured as data port: has no effect on AUX port.  
*2. [BREAK] = [PAUSE] pressed together with [CTRL].  
*3. [SYS REQ] = [PRINT SCREEN] pressed together with [CTRL].  
*4. If screen is split.  
*5. Splits screen at line 12.  
*6. Only active at Ethernet mode ON.  
Download from Www.Somanuals.com.4A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.4 TERMINAL Command Guide  
4.4.1 Commands Supported in ASCII Personalities  
Table 8 lists all the ASCII commands recognized by the terminal. The native mode code for the command is given in the second  
column. (The native mode includes WY-325,WY-120 and WY-60.) The remaining columns show the support for the command in  
other ASCII personalities according to the following notations:  
Same  
Same as native code (code is native to other terminal also)  
Wyse  
Same as native code (Wyse enhancement- code not native to other terminal)  
ENH  
Same as native code when enhance mode is ON (Wyse enhancement - code not native to other terminal) A code listed under a  
nonnative personality indicates that the related terminal's native code is supported.  
A blank in any column indicates that the command is not supported.  
Variables are shown in italics. Their values are listed in alphabetical order at the end of the table.  
Footnotes are found at the end of Table 8 on page 46.  
Table 8- Commands Supported in ASCII Personalities  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Monitor Mode  
Monitor mode on  
Monitor mode off  
ESC U  
ESC u  
or ESC X  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
------------------------------------------------------------------------------------------------------------------------------------------------------------  
Selecting Personalities  
Enhance mode off  
Enhance mode on  
ESC ~ SPACE Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ESC v SPACE  
ESC v !  
ESC v "  
ESC ~ !  
ESC ~"  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Select WY-50+ mode  
Select TVI 910+ mode  
Select TVI 925 mode  
Select ADDS VP A2 mode  
Select Console ANSI mode  
Select Native mode  
Select PC Term mode  
Select VT52 mode  
Wyse  
Wyse  
Wyse  
Wyse  
Wyse  
Wyse  
Wyse  
Wyse  
Wyse  
ESC ~ #  
ESC ~ $  
ESC ~ %  
ESC ~ A  
ESC ~ 4  
ESC ~ 5  
ESC ~ 6  
ESC ~ ;  
ESC v #  
ESC v $  
ESC v %  
ESC v A  
ESC v 4  
ESC v 5  
ESC v 6  
ESC v ;  
Select VT100 mode  
Select PCGAPHIC mode*1  
Select VT220-7 mode  
Select VT220-8 mode  
ESC ~ I  
ESC ~ <  
ESC ~ =  
Same  
Same  
Same  
ENH  
ENH  
ENH  
Wyse  
Wyse  
Wyse  
ESC v I  
ESC v <  
ESC v =  
Select WY-325 mode*3  
ESC ~ B  
Same  
ENH  
Wyse  
ESC v B  
---------------------------------------------------------------------------------------------------------------------------------------------------------------  
Communicating with the computer  
Enable transmission  
Stop transmission Disconnect  
Send ACK (if ACK mode on)  
CTRL Q  
CTRL S  
CTRL E  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Wyse  
Same  
Same  
Same  
---------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
-------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
-------------------------------------------------------------------------------------------------------------------------------------------------------------------  
ACK mode off  
ACK mode on  
Full-duplex mode on  
Half-duplex mode on  
Block mode on  
ESC e 6  
ESC e 7  
ESC C ESC D F  
ESC C ESC D H  
ESC B  
Same  
Same  
Same  
Same  
Same  
ENH  
ENH  
Same  
Same  
Same  
ESC }  
ESC {  
Same  
ESC C  
ENH  
Block mode off (conversation)  
Half-duplex block mode on  
Set Serial 1 port receive  
handshaking protocol  
Set Serial 1 port transmit  
handshaking protocol  
Set maximum data transmission  
speed for host port  
ESC D H ESC B  
ESC c 2 hndshk  
Same  
Same  
Same  
ENH  
ENH  
ESC c 4 hndshk  
Same  
ESC c 6 max  
Set Serial 1 port operating  
parameters  
Set Serial 2 port operating  
parameters  
ESC c 0 baud  
stop parity word  
ESC c 1 baud  
stop parity word  
Enable DTR Serial port 1  
Handshaking  
Enable X-on/X-off Serial port 1  
Program answerback message  
CTRL N  
CTRL N  
CTRL O  
CTRL N  
CTRL O  
CTRL O  
ENH  
ESC c; answer  
CTRL Y  
Same  
Conceal answerback message  
Send answerback message  
Turn answerback mode off  
Turn answerback mode on  
ESC c =  
ESC c <  
ESC e SP  
ESC e !  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling the Terminal and Keyboard  
Sound bell  
CTRL G  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
Same  
ENH  
CTRL B  
CTRL D  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
Same  
Same  
Select bell volume  
Unlock keyboard  
Lock keyboard  
CAPS LOCK off  
CAPS LOCK on  
NUM LOCK off  
ESC c \volume  
CTRL N or ESC"  
CTRL O or ESC#  
ESC e '  
ESC e &  
ESC e @  
ESC e A  
ESC e B  
ESC e C  
ESC e $  
ESC e %  
ESC e L  
ESC "  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ESC "  
ESC #  
ESC SP M  
ESC SP L  
ESC SP K  
ESC SP J  
ESC SP O  
ESC SP N  
ESC <  
ESC >  
ESC n  
ESC o  
NUM LOCK on  
SCROLL LOCK off  
SCROLL LOCK on  
Keyclick off  
Keyclick on  
Margin bell off  
ENH  
Same  
Same  
Same  
Same  
Same  
Same  
ESC <  
ESC >  
ENH  
Margin bell on  
ESC e M  
ESC ' J  
ESC e H  
ENH  
Set margin bell at curs position  
Select standard ASCII key code  
mode  
Select PC scan code mode  
Key repeat off  
Key repeat on  
ESC e I  
ESC e ,  
ESC e -  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
Read keyboard status  
ESC [  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Redefining the keys  
Clear function key definition  
ESC z fkey  
DEL  
Same  
Same  
Clear key direction and definition ESC Z dir  
key/fkey DEL  
ENH  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
--------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Program function key definition  
ESC z fkey  
sequence DEL  
ESC Z dir  
Same  
Same  
ENH  
ENH  
Program key direction and  
definition  
Wyse  
ESC | p1 p2  
sequence  
CTRL Y  
key/fkey  
sequence DEL  
Read key direction and definition ESC Z ~key  
Same  
or ESC Z ~fkey  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Screen and Cursor Display  
Screen display off  
Screen display on  
Screen saver off  
Screen saver on  
Set reverse screen  
ESC ` 8  
ESC ` 9  
ESC e P  
ESC e Q  
ESC ^ 1  
Same  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ESC o  
ESC n  
ENH  
ENH  
ESC b  
ESC O  
ESC N  
Restore normal screen  
Set scrolling speed and type  
ESC ^ 0  
ESC ` scroll  
Same  
Same  
ENH  
ENH  
ESC d*4  
Smooth scrolling on  
ESC 8*5  
ESC 9*5  
ESC . cursor1 ESC.cursor1  
Smooth scrolling off  
Set cursor display features  
Cursor display off  
ESC ` cursor  
ESC ` 0  
ESC ` 1  
Same  
Same  
Same  
ENH  
CTRL W  
CTRL X  
Cursor display on  
25th line display off  
ESC e  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Displaying the Message Fields  
Extended status line on  
Standard status line on  
Status line off  
Program/display CPU message  
on status line  
ESC ` a  
ESC ` b  
ESC ` c  
ESC F  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
message CR  
Program CPU message on  
ESC z ( text  
Same  
Same  
ENH  
ENH  
ESC f*5  
ESC f  
unshifted lable line*6  
Program CPU message on shifted ESC z ) text  
CR  
text CR  
text CR  
label line  
CR  
Turn off shifted label line  
Clear unshifted label line  
Clear shifted label line  
ESC z DEL  
ESC z ( CR  
ESC z ) CR  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
Program/display function key label ESC z field  
label CR  
Clear function key label  
ESC z field  
Same  
ENH  
ENH  
CR  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Defining the data Area  
Select 80-column display  
ESC ` :  
ESC ` ;  
ESC e F  
ESC e G  
ESC e .  
ESC e /  
Same  
Same  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
Select 132-column display  
Economy 80-column mode off  
Economy 80-column mode on  
Width-change-clear mode off  
Width-change-clear mode on  
Display 24 data lines*7  
ESC e (  
Same  
ENH  
Display 25 data lines*7  
ESC e )  
Same  
ENH  
ESC ^  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
--------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Display Memory/Split Screen  
Divide memory into pages  
Display previous page  
ESC w length  
ESC w B or ESC J*8  
Same  
Same  
ENH  
ENH  
ESC J  
ESC K  
Display next page  
Display page n  
Split screen horizontally  
(simple split)  
ESC w C or ESC K*8  
ESC w page  
ESC x A line  
Same  
Same  
Same  
ENH  
ENH  
Split screen horizontally  
(simple split) and clear pages  
Split screen horizontally  
(adjustable split) and clear pages  
Split screen horizontally  
(adjustable split)  
ESC x 1 line  
ESC x 3 line  
ESC x C line  
Same  
Same  
Same  
Activate upper window  
Activate lower window  
ESC ]  
ESC }  
Same  
Same  
Activates other window (or page *8) ESC J or ESC K  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
ESC J*5  
Lower horizontal split  
ESC x P  
ESC x R  
ESC w E  
ESC w F  
ESC x @  
ESC x 0  
Raise horizontal split  
Roll window up in page  
Roll window down in page  
Redefine screen as one window  
Redefine screen as one window  
and clear pages  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Display Attributes  
Assign display attribute to a  
message field  
Assign character display attribute ESC G attr  
ESC A mf attr  
Same  
Same  
ESC \*4  
ENH  
Same  
Same  
Character attribute mode off  
Character attribute mode on  
Page attribute mode on  
Line attribute mode on  
Assign write-protected character  
display attribute  
ESC e 0  
ESC e 1  
ESC e 2  
ESC e 3  
ESC `wpca  
Same  
Same  
Same  
ESC 0 wpca1  
Wyse  
Clear unprotected page to  
display attribute  
ESC !  
ENH  
attr  
Assign line attribute  
ESC G lattr  
Same  
ENH  
Redefine color map values*9  
ESC d y  
fcolor  
bcolor map  
Set tag protect attribute  
Reset tag protect attribute  
CTRL N  
CTRL O  
Select a predefined color palette*9 ESC d z  
palette  
Map blank attribute*9  
ESC d {  
Map reverse attribute*9  
ESC d |  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Protecting Data  
Write-protect mode off  
Write-protect mode on  
Clear cursor column to  
write-protected spaces  
Protect mode off  
ESC (  
ESC )  
ESC V  
Same  
Same  
Same  
CTRL O  
CTRL N  
ENH  
Same  
Same  
Same  
Same  
Same  
ESC ,  
ESC &  
Same  
Same  
ENH  
ENH  
Same  
Wyse  
Same  
Same  
Protect mode on  
------------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
--------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Graphics Characters  
Graphics mode on  
Graphics mode off  
Display graphics character  
ESC H  
ESC H  
ESC H ldraw  
CTRL B  
CTRL C  
Same  
Same  
Same  
ESC $  
ESC %  
ESC $  
ESC %  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling the Cursor  
Cursor left (backspace)  
CTRL H  
Same  
Same  
Same  
Same  
or CTRL U  
Same  
Same  
Cursor right  
Cursor up; no scroll  
CTRL L  
CTRL K  
Same  
Same  
CTRL F  
CTRL Z  
Same  
Same  
Cursor up; scroll (reverse linefeed) ESC j  
Cursor down; no scroll  
Same  
ENH  
Same*10  
CTRL V  
Same  
Same  
CTRL V  
Same  
Cursor down; scroll (Linefeed)  
Cursor to start of line  
Same  
CTRL J  
CTRL M  
Same  
Same  
Same  
Same  
Same  
Cursor to start of next line  
Home cursor  
CTRL _  
ESC {  
or CTRL ^  
Same  
Same  
ENH  
ENH  
or CTRL A  
Same  
Wyse  
Same  
Same  
CTRL ^  
Cursor to specific column  
Cursor to specific line  
End-of-line wrap off  
CTRL P col  
CTRL K line  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
ENH  
or ESC Y  
ENH  
ESC ] *11  
ESC [  
ESC d .  
ESC d /  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
ESC 0  
ESC ~  
ESC 9  
ESC 8  
End-of line wrap on  
Received CR mode off  
Received CR mode on  
Autopage mode off  
ESC e 4  
ESC e 5  
ESC d *  
ESC d +  
ESC N  
ESC O  
ESC = line  
col  
ENH  
ENH  
ESC w  
ESC v  
Autopage mode on  
Autoscrolling mode off  
Autoscrolling mode on  
Address cursor in current  
80-column page  
Address cursor in specific  
80-column page  
Same  
Same  
Same  
ESC w @ page  
line col  
ESC - wnd/  
Same  
Same  
ESC - page  
line col  
Address cursor in specific  
ENH  
80-column window/page*8  
Address cursor in specific  
80/132-column current page  
Read cursor line and column  
address in 80-column current  
page  
Read 80-column page number  
and cursor address  
Read 80-column window/page  
number and cursor address  
Read cursor address in 80/132-  
column page  
page line col  
ESC a lll R  
ccc C  
Same  
Same  
ENH  
ENH  
Same  
Same  
ESC ?  
Same  
Same  
ESC w  
ESC /  
ESC b  
Same  
Same  
Same  
ENH  
ENH  
ENH  
Same  
----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Editing  
Clear all tab stops  
Set tab stop  
Clear tab stop  
Tabulate cursor  
Backtab  
ESC 0  
ESC 1  
ESC 2  
ESC i or CTRL I  
ESC I  
Same  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
ENH  
ESC 3  
Same  
Same  
CTRL I  
Same  
ESC I  
ENH  
ESC 3  
Same  
Same  
CTRL I  
Same  
ESC i  
ESC Z  
Same  
Same  
Field tab  
Insert mode on, replace mode off ESC q  
Insert mode off, replace mode on ESC r  
Insert space character  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
Same  
ESC Q  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
--------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Editing (Cont'd)  
Insert line of spaces  
Delete cursor character  
Delete cursor line  
ESC E  
ESC W  
ESC R  
Same  
Same  
Same  
ENH  
ENH  
ESC l  
Same  
Same  
Same  
Same  
Same  
Same  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Clearing Data  
Clear page to nulls  
Clear page to spaces  
Clear page to write-protected  
spaces  
ESC *  
ESC +  
ESC ,  
Same  
Same  
Same  
ENH  
ENH  
ENH  
Same  
Same  
Same  
Same  
Same  
Clear unprotected page to spaces ESC ; or CTRL Z  
Same  
ESC ;  
ENH  
ENH  
ENH  
ESC ;  
or ESC +  
Same  
Clear unprotected page to nulls  
Clear unprotected page to  
a specific character  
ESC :  
ESC .char  
Same  
Same  
Clear unprotected page to  
protected spaces  
Clear unprotected page to  
display attribute  
Clear unprotected page to spaces ESC Y  
from cursor  
Clear unprotected page to nulls  
from cursor  
Clear unprotected line to spaces  
from cursor  
Clear unprotected line to nulls  
from cursor  
ESC ,  
ENH  
ESC ! attr  
Same  
ENH  
ESC k  
ENH  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
ESC F  
ESC y  
ESC T  
ESC t  
Same  
Same  
ESC K  
ENH  
Same  
Fill page with H's  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Sending data  
Begin print / send at top of page  
Begin print / send at top of screen ESC d&  
Send cursor character  
Send line through cursor  
Send unprotected line through  
cursor  
ESC d'  
Same  
Same  
Same  
Same  
Same  
ENH  
ENH  
ESC M  
ESC 6  
ESC 4  
Same  
Same  
ESC 6  
ESC 4  
Send page through cursor  
Send unprotected page through  
cursor  
ESC 7  
ESC 5  
Same  
Same  
ENH  
Same  
Same  
ESC 5  
ESC 7  
Mark block beginning  
Mark block end  
Send entire block  
ESC 8  
ESC 9  
ESC s  
ESC S  
Same  
Same  
Same  
Same  
ENH  
ENH  
ENH  
ENH  
Same  
Same  
Same  
Same  
ESC [  
ESC D  
Send unprotected  
Report terminal status  
Report attribute under cursor  
---------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.4A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
Table 8- Commands Supported in ASCII Personalities (Cont'd)  
---------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
--------------------------------------------------------------------------------------------------------------------  
Native  
Mode  
Wyse  
WY-50+  
ADDS  
VP A2  
TVI  
910+/925  
PC  
Term  
FUNCTION  
--------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Print Functions  
Print formatted page  
Print formatted unprotected page ESC @  
ESC P  
Same  
Same  
ENH  
ENH  
Same  
Same  
Print unformatted page  
Select Parallel printer  
Select Serial printer  
ESC p or ESC L  
ESC d (  
ESC d )  
CTRL T  
CTRL R  
CTRL T  
ESC d #  
ESC d $  
ESC d %  
ESC d SPACE  
ESC d !  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
ESC p  
Same  
Same  
Same  
Same  
ESC 4  
ESC 3  
ESC L*11  
Auxiliary print mode off  
Auxiliary print mode on  
Transparent print mode off  
Transparent print mode on  
Bi-directional mode off  
Bi-directional mode on  
Auxiliary receive mode off  
Auxiliary receive mode on  
Set print terminator  
ESC A  
ESC @  
ESC a  
ESC `  
CTRL T  
CTRL  
ESC A  
ESC a  
ESC `  
CTRL T  
CTRL R  
ESC p  
ESC x  
ESC p  
ESC x  
Define delimiters  
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------  
Character Sets  
Select primary character set  
Select secondary character set  
Define primary character set  
Define secondary character set  
Load font bank with predefined  
ESC c D  
ESC c E  
ESC c B bank  
ESC c C bank  
ESC c @ bank  
set  
Same  
Same  
Same  
Same  
Same  
Clear font bank  
Define and load character  
ESC c ? bank  
ESC c A bank  
pp bb...bb  
CTRL Y  
Same  
Same  
------------------------------------------------------------------------------------------------------------------------------------------------------  
*1. PCG ALPHA in Mono. Text Model machine.  
*3. Valid only in Color Model machine.  
*4. With enhance mode off.  
*5. With enhance mode on.  
*6. Automatically display in native mode. May be hidden by assigning blank attribute (ESC A l l).  
*7. Screen cleared.  
*8. If screen is not split.  
*9. In WY-325 only  
*10. In TeleVideo 925 only  
*11. In TeleVideo 910+ only  
Download from Www.Somanuals.com.4A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5.4.2 Variable Values for Table 8 Commands  
answer Up to 20 characters to define answerback message  
attr  
SPACE  
Display Attributes  
Space character  
Normal  
Blank  
Blink  
attr  
p
q
r
s
t
u
v
w
x
y
z
Display Attributes  
Dim  
Dim and invisible  
Dim and blink  
Dim, blink, invisible  
Dim and reverse  
Dim, reverse, invisible  
Dim, reverse, blink  
Dim, reverse, blink invisible  
Dim and underline  
Dim, underline, invisible  
Dim, underline, blink  
Dim, underline, blink invisible  
Dim, underline, reverse  
Dim, underline, reverse invisible  
Dim, underline, reverse blink  
Dim, underline, reverse blink, invisible  
0
1
2
3
4
5
6
7
8
9
:
Blink and Blank  
Reverse  
Reverse and invisible  
Reverse and blink  
Reverse, blink, invisible  
Underline  
Underline and invisible  
Underline and blink  
Underline, blink, invisible  
Underline and reverse  
Underline, reverse, invisible  
Underline, reverse, blink  
Underline, reverse, blink invisible  
{
;
|
<
=
>
?
}
~
DEL  
bank  
0
1
Font Bank*a  
Font bank 0  
Font bank 1  
bank  
2
3
Font Bank*a  
Font bank 2  
Font bank 3  
*a Holds predefined character set  
baud  
Baud Rate  
115200  
76800  
57600  
38400  
baud  
Baud Rate  
19200  
9600  
7200  
4800  
baud  
Baud Rate  
2400  
1200  
600  
300  
baud  
Baud Rate  
200  
134.5  
110  
0
1
2
3
4
5
6
7
8
9
:
<
=
>
?
;
50  
bb...bb 32-byte character string defining bit pattern of character  
------------------------------------------------------------------------------------------------------------------------------------------------------  
bcolor Background Color bcolor Background Color  
1
2
3
4
Black  
Blue  
Green  
Cyan  
5
6
7
8
Red  
Magenta  
Yellow  
White  
ccc One-to three-decimal value of column relative to home  
char Character that replaces unprotected characters  
col See line/col  
color  
color  
Black  
Blue  
Green  
Cyan  
Red  
color  
6
7
8
B
C
color  
Magenta  
Yellow  
White  
Dim blue  
Dim green  
color  
color  
Dim cyan  
Dim red  
Dim magenta  
Dim yellow  
Dim white  
1
2
3
4
5
D
E
F
G
H
cursor Cursor Display  
cursor Cursor Display  
0
1
2
Cursor display off  
Cursor display on  
Steady block cursor  
3
4
5
Blinking line cursor  
Steady line cursor  
Blinking block cursor  
dir  
0
1
Direction  
Normal  
Remote  
Local  
2
Download from Www.Somanuals.com.4A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
-----------------------------------------------------------------------------------------------------------------------------------------------------  
Variable Values for Table 8 Commands (Cont'd)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
fcolor  
Foreground Color  
Black  
Blue  
Green  
Cyan  
fcolor  
Foreground Color  
Red  
Magenta  
Yellow  
1
2
3
4
5
6
7
8
White  
field  
field  
field  
field  
Key  
F1  
F2  
F3  
F4  
F5  
F6  
Unshifted  
shifted  
Key  
F7  
F8  
Unshifted  
shifted  
0
1
2
3
4
5
P
Q
R
S
T
6
7
8
9
:
V
W
X
Y
Z
[
F9  
F10  
F11  
F12  
U
;
Function  
Key  
F1  
F2  
F3  
F4  
F5  
F6  
fkey  
Unshifted  
@
A
B
C
D
E
fkey  
Shifted  
`
a
b
c
d
e
Function  
Key  
F7  
F8  
F9  
F10  
F11  
F12  
fkey  
Unshifted  
F
G
H
I
fkey  
Shifted  
f
g
h
i
J
K
j
k
hndshk Handshaking Protocol Receive Transmit  
0
1
2
3
None (default)  
XON/XOFF  
DTR  
None (default)  
XON/XOFF  
Both  
Keyboard Style  
key  
Enhanced PC  
key  
&
"
Enhanced PC  
key  
Enhanced PC  
RETURN  
SPACE ESC  
SHIFT TAB →  
BACKSPACE  
SHIFTBACKSPACE  
SHIFT →  
$
)
%
!
SHIFT ESC  
SHIFT RETURN  
HOME  
TAB →  
SHIFT HOME  
'
*
/
3
s
6
R
X
\
SHIFT DELETE  
PRINT SCREEN  
+
0
,
ENTER kpd  
SHIFT ↑  
SHIFT ↓  
SHIFT ←  
4
q
p
r
SHIFT ENTER kpd  
INSERT  
SHIFT PRINT SCREEN  
END  
1
-
SHIFT INSERT  
PAGE DOWN  
SHIFT PAGE DOWN  
DELETE  
]
SHIFT END  
:
PAGE UP  
2
.
w
5
;
SHIFT PAGE UP  
label 9 characters (80 columns); 7 characters (132 columns)  
lattr  
@
A
Line Attribute  
Single-high, single-wide characters  
Single-high, double-wide characters.  
B
C
D
E
Top half of double-high, single-wide characters  
Bottom half of double-high, single-wide characters  
Top half of double-high, double-wide characters  
Bottom half of double-high, double-wide characters  
ldraw Graphics  
ldraw Graphics  
ldraw Graphics  
ldraw Graphics  
Character  
Character  
Character  
Character  
0
1
2
3
4
5
6
7
8
9
:
=
>
?
;
Download from Www.Somanuals.com.4A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Variable Values for Table 8 Commands (Cont'd)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
length Multiple  
Length of Page  
G
H
1xlines  
2xlines  
Equal to the number of data lines  
Double the number of data lines  
I*b  
4xlines  
Four times the number of data lines  
*b Available only in WY-50+ personality.  
Line/Column  
Line/Column  
Line/Column  
Line/Column  
line/col*c  
line/col*c  
line/col*c  
line/col*c  
1
2
3
4
5
6
7
8
Space  
!
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
8
9
:
;
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
P
Q
R
S
T
U
V
W
X
Y
Z
[
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
~
"
#
$
%
&
'
(
)
*
+
,
<
=
>
?
@
A
B
C
D
E
F
G
H
I
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
\
]
-
.
/
^
_
`
a
b
c
d
e
f
0
1
2
3
4
5
6
7
J
K
L
M
N
O
g
DEL/RUB  
*c Native codes also recognized in WY-50+, TVI 910+/925, and PC Term personalities, and in ADDS VP A2 personality absolute  
cursor addressing.  
lll One- to three-decimal value of line relative to home  
map  
Definition  
map  
Definition  
1
Normal  
5
Underline  
2
3
Reverse (or blank*d)  
Intensity  
6
7
Underline and reverse (or blank*d)  
Underline and intensity  
4
Intensity and reverse (or blank*d)  
8
Underline, intensity, and reverse (or blank*d)  
*d. Colors mapped to reverse or blank depending on the setting of the Color Map setup parameter or the equivalent  
escape sequences.  
Max  
Maximum Speed  
1
2
3
60 characters per second  
No limit (default)  
150 characters per second  
message 46 characters (80 columns); 98 characters (132 columns)  
mf  
0
1
Screen Area*e  
Data area  
Function key label line  
mf  
2
3
Screen Area*e  
Terminal message field  
Computer message field  
*e In native mode, only the reverse attribute can be assigned to the data area.  
Download from Www.Somanuals.com.5A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Variable Values for Table 8 Commands (Cont'd)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
p1  
1
2
3
4
Function Key  
p1  
6
7
8
9
Function Key  
F1  
F2  
F3  
F4  
F5  
F6  
F7  
F8  
F9  
F10  
5
0
p2  
1
2
Direction  
Remote  
Local  
3
Normal  
------------------------------------------------------------------------------------------------------------------------------------------------------  
page  
Page  
0
1
2
3
4
5
6
page 0  
page 1  
page 2  
page 3  
page 4  
page 5  
page 6  
In the 80 columns mode: There have 4 pages of display memory.  
In the 132 columns mode: There have 3 pages of display memory.  
In the Econ-80 columns mode: There have 7 pages of display memory.  
palette Color Palette  
palette Color palette  
palette Color palette  
0
1
2
3
Palette 0  
Palette 1  
Palette 2  
Palette 3  
4
5
6
7
Palette 4  
Palette 5  
Palette 6  
Palette 7  
8
9
.
Palette 8  
Palette 9  
Palette 10  
parity Parity Bits  
parity Parity Bits  
0
1
None  
Odd  
2
3
Mark  
Even  
pp 2-byte hex value of character position*f.  
*f In the illustrations, DEC = decimal value; HEX = hexadecimal value. Read across, then down.  
Scroll Scrolling Type  
Speed(lps)  
@
<
=
>
?
Jump scroll  
Smooth scroll  
Smooth scroll  
Smooth scroll  
Smooth scroll  
1
2
4
8
sequence Up to 64 bytes to be loaded in function key  
------------------------------------------------------------------------------------------------------------------------------------------------------  
set  
@
A
B
D
Predefined Character Set  
Native Mode  
PC Multinational  
Standard ASCII  
PC Standard  
G
Standard ANSI  
stop  
stopbits  
0
1
1
2
text 78 characters (80 columns); 130 characters (132 columns)  
volume  
#
"
BELL Volume  
Loud  
volume  
BELL Volume  
!
Low  
Off  
Medium  
SP  
Download from Www.Somanuals.com.5A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Variable Values for Table 8 Commands (Cont'd)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
wnd/page  
Window or Page  
0
1
Page 0 or upper window  
Page 1 or lower window  
word  
0
1
Data Word  
7 bits  
8 bits  
wpca Write-Protected Display Attribute  
wpca Write-Protected Display Attribute  
6
7
Reverse*g  
Dim*g  
C
E
Invisible on  
Underline on  
A
B
Normal*g  
Blink on  
F
G
Reverse on  
Dim on  
*g Clears other write-protected attributes  
wpca1  
Display Attribute  
Normal  
Dim  
Blink  
Dim/Blink  
Invisible  
Reverse (Rev)  
Rev/Dim  
wpca1  
H
I
J
K
L
X
Y
Z
[
Write-Protected Display Attribute  
Normal  
Dim  
Blink  
Dim/Blink  
Invisible  
Reverse (Rev)  
Rev/Dim  
@
A
B
C
D
P
Q
R
S
T
.
Rev/Blink  
Rev/Blink  
Rev/Dim/Blink  
Rev/Invisible  
Underline (UL)  
UL/Dim  
Rev/Dim/Blink  
Rev/Invisible  
Underline (UL)  
UL/Dim  
\
h
i
a
b
UL/Blink  
j
UL/Blink  
c
p
q
r
UL/Dim/Blink  
UL/Rev  
UL/Rev/Dim  
UL/Rev/Blink  
UL/Rev/Dim/Blink  
k
x
y
z
{
UL/Dim/Blink  
UL/Rev  
UL/Rev/Dim  
UL/Rev/Blink  
UL/Rev/Dim/Blink  
s
4.5 ANSI Command Guide  
4.5.1 VT100, VT220 and Console ANSI Command Guide  
Table 9 -Supported VT100,VT220 and Console ANSI Commands  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
--------------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling Functional modes*1  
Lock keyboard  
Unlock keyboard  
CSI 2 h  
CSI 2 l  
Same  
Same  
Monitor mode on *2  
Monitor mode off  
Insert mode on  
Insert mode off  
Local echo off  
Local echo on  
New line mode on  
New line mode off  
Cursor keys send application-dependent codes  
Cursor keys send cursor movement codes  
VT100 mode on  
VT52 mode on  
National character set mode on  
National character set mode off  
CSI 3 h  
CSI 3 l  
CSI 4 h  
CSI 4 l  
CSI 12 h  
CSI 12 l  
CSI 20 h  
CSI 20 l  
CSI ?1 h  
CSI ?1 l  
CSI ?2 h or CSI 61 "p  
CSI ?2 l  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
CSI ?42 h  
CSI ?42 l  
Download from Www.Somanuals.com.5A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
132-column display  
80-column display  
Smooth scrolling on  
Jump scrolling on  
Reverse screen video on  
Normal screen video on  
Line 1 is top of scrolling region  
Line 1 is top of display area  
Autowrap on  
Autowrap off  
Autorepeat on  
Autorepeat off  
Block mode on  
CSI ?3 h  
CSI ?3 l  
CSI ?4 h  
CSI ?4 l  
CSI ?5 h  
CSI ?5 l  
CSI ?6 h  
CSI ?6 l  
CSI ?7 h  
CSI ?7 l  
CSI ?8 h  
CSI ?8 l  
CSI ?10 h  
CSI ?10 l  
CSI ?18 h  
CSI ?18 l  
CSI ?19 h  
CSI ?19 l  
CSI ?25 h  
CSI ?25 l  
CSI 30 h  
CSI 30 l  
CSI 31 h  
CSI 31 l  
CSI 32 h  
CSI 32 l  
CSI 33 h  
CSI 33 l  
CSI 34 h  
CSI 34 l  
CSI 35 h  
CSI 35 l  
CSI 37 h  
CSI 37 l  
CSI 38 h  
CSI 38 l  
CSI 40 h  
CSI 40 l  
CSI 54 h  
CSI 54 l  
CSI 62;2"p  
CSI 62;1"p  
ESC space G  
ESC space F  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Block mode off  
Send form feed after print screen operation  
No form feed sent after print screen operation  
Print full screen  
Print scrolling region  
Display cursor  
Cursor off  
Blank screen  
Display screen  
Display status line  
Blank status line  
Screen saver  
Screen saver off  
Cursor steady (nonblinking)  
Cursor blinking  
Underline cursor on  
Block cursor on  
Don't clear screen after width change  
Clear screen after width change  
Send erasable and nonerasable characters  
Send only erasable characters  
Send full screen  
Send scrolling region  
Turn 25th line on  
Turn 25th line off  
Select standard ANSI key codes  
Select PC scan codes  
VT220 8-bit mode on  
VT220 7-bit mode on  
8-bit transmission mode on (VT220)  
7-bit transmission mode on (VT220)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Select next page  
Select preceding page  
Select page 0  
CSI U  
CSI V  
CSI 0 z  
CSI 1 z  
Select page 1  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Character Set Selection ESC Ps final Same  
Ps  
(
)
Label assigned  
G0  
G1  
Ps  
*
+
Label assigned  
G2(VT220 only)  
G3(VT220 only)  
Download from Www.Somanuals.com.5A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
final  
Final character  
final  
Final character  
A
Designating UK ANSI character set  
<
Designating DEC supplemental(VT220 only)  
B
0
Designating ASCII character set  
Designating DEC special graphics  
DSCS* Designating Down-line loadable character set  
* DSCS can consist of zero, one or two intermediate character and a final character. Intermediate characters are  
in the range of 2/0 to 2/15. Final characters are in the range of 3/0 to 7/14  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Load G0 character set into GL  
Load G1 character set into GL  
Load G1 character set into GR  
Load G2 character set into GL  
Load G2 character set into GR  
Load G3 character set into GL  
Load G3 character set into GR  
CTRL O  
CTRL N  
ESC ~  
ESC n  
ESC }  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
ESC o  
ESC |  
Shift G2 character set into GL for one character only ESC N  
Shift G3 character set into GL for one character only ESC O  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling Character, Field, and Line Attributes  
Define character attributes*3  
CSI Ps m  
Same  
Ps  
0
1
4
5
7
8
22  
24  
Character Attribute  
Normal (all attributes off)  
Bold (blank off)  
Underline  
Blink  
Reverse  
Blank (bold off)  
Normal intensity  
Underline off  
Ps  
25  
27  
28  
30  
31  
32  
33  
34  
Character Attribute  
Blink off  
Reverse off  
Blank off  
Black character  
Red character  
Green character  
Brown character (Bold on = Yellow)  
Blue character  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Ps  
35  
36  
37  
40  
41  
42  
Character Attribute  
Magenta character  
Cyan character  
Ps  
43  
44  
45  
46  
47  
Character Attribute  
Brown background (Bold on = Yellow)  
Blue background  
Magenta background  
Cyan background  
White character  
Black background  
Red background  
Green background  
White background  
Select Graphic Rendition (Console ANSI mode only)  
CSI ps m  
ps  
10  
11  
12  
Function  
Select Primary Font  
Select First Altemate Font. Allows ASCII characters less than 32 to be displayed as ROM character.  
Select Second Alternate Font. Toggles high bit of extended ASCII code before displaying as ROM character.  
Set bold background bit  
ESC[ =PnE  
same  
Pn = 0: set bit 7 of attribute byte as B/G intensity  
1: set bit 7 of attribute byte as B/G blink  
Set normal foreground color  
Set normal background color  
Set reverse foreground color  
Set reverse background color  
Set graphic foreground color  
Set graphic background color  
Set border color  
ESC[ = Psn F  
ESC[ = Psn G  
ESC[ = Psn H  
ESC[ = Psn I  
ESC[ = Psn J  
ESC[ = Psn K  
ESC[ = Psn A  
same  
same  
same  
same  
same  
same  
same  
Download from Www.Somanuals.com.5A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Psn  
0
1
2
3
Color  
Black  
Blue  
Green  
Cyan  
Psn  
4
5
6
7
Color  
Red  
Magenta  
Brown  
White  
Psn  
8
9
10  
11  
Color  
Gray  
Lt.Blue  
Lt. Green  
Lt. Cyan  
Psn  
12  
13  
14  
15  
Color  
Lt. Red  
Lt. Magenta  
Yellow  
Lt. White  
Access alternate graphic set  
Define erasable character  
Define non-erasable character  
Define top half of double-high, double-wide line  
Define bottom half of double-high, double-wide line ESC # 4  
Define single-high, single-wide line  
Define single-high, double-wide line  
Define top half of double-high, single-wide line  
Define bottom half of double-high, single-wide line  
CSI Png  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
CSI 0 "q or CSI 2 "q  
CSI 1 "q  
ESC # 3  
ESC # 5  
ESC # 6  
ESC # :  
ESC # ;  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling the Cursor  
Display cursor  
Cursor off  
Cursor steady (nonblinking)  
Cursor blinking  
Underline cursor on  
CSI ?25 h  
CSI ?25 l  
CSI 33 h  
CSI 33 l  
CSI 34 h  
CSI 34 l  
CSI ?1 h  
CSI ?1 l  
CSI n G or CSI n `  
CSI n A  
CSI n B or CSI n e  
CSI n C or CSI n a  
CSI n D  
CSI n E  
CSI n F  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Block cursor on  
Cursor keys send application-dependent codes  
Cursor keys send cursor movement codes  
Move cursor to n column  
Move cursor up n lines  
Move cursor down n lines  
Move cursor right n columns  
Move cursor left n columns  
Move cursor down cursor n line to column 1  
Move cursor up n lines to column 1  
Move cursor to line n  
CSI n d  
Move cursor to line n1, column n2  
CSI n1; n2 H  
or CSI n1; n2 f  
IND  
or ESC D  
CTRL J  
or CTRL K or CTRL L  
RI  
or ESC M  
NEL or ESC E  
ESC 7  
Move cursor down one line in current column,  
scroll up if at bottom line  
Move cursor down one line in current column,  
execute CR if linefeed mode is on  
Move cursor up one line in current column,  
scroll down if at top line  
Move cursor down one line to column 1  
Save display attributes, cursor position, character  
sets,wrap flag and origin mode status  
Restore last saved display attributes, cursor position, ESC 8  
character set, wrap flag, and origin mode status  
Backspace cursor  
Move cursor to next tab stop  
Move cursor to column 1 of current line  
or CSI s  
or CSI u  
CTRL H  
CTRL I  
CTRL M  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Editing Functions  
Erase from cursor to end of display  
Erase from start of display to cursor  
Erase entire display  
Erase from cursor to end of line  
Erase from start of line to cursor  
Erase entire line  
CSI 0 J  
CSI 1 J  
CSI 2 J  
CSI 0 K  
CSI 1 K  
CSI 2 K  
CSI ?0 J  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Erase erasable characters from cursor to  
end of display  
Download from Www.Somanuals.com.5A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Editing Functions (Cont'd)  
Erase erasable characters from start of display  
to cursor  
Erase erasable characters in entire display  
Erase erasable characters from cursor to end of line CSI ?0 K  
Erase erasable characters from start of line  
to cursor  
CSI ?1 J  
CSI ?2 J  
Same  
Same  
Same  
Same  
CSI ?1 K  
Erase erasable characters from entire line  
Erase n characters beginning at cursor  
Insert n blank characters beginning at cursor  
Insert n blank lines beginning at cursor line  
Delete n line beginning at cursor line  
Delete n characters beginning at cursor  
CSI ?2 K  
CSI n X  
CSI n @  
CSI n L  
CSI n M  
CSI n P  
Same  
Same  
Same  
Same  
Same  
Same  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling Margins  
Set top/bottom margins of scrolling  
CSI t;b r  
Same  
t: Top line number  
b: Bottom line number (optional; if omitted, treated as bottom screen line)  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling Tabs  
Clear tab stop at cursor  
Clear all tab stops  
Set tab stop at cursor  
Set tab stop every 8th column  
Move forward n tab stops  
Move backward n tab stops  
Move cursor to next tab stop  
CSI 0 g or CSI 2 W  
CSI 3 g or CSI 5 W  
CSI 0 W or ESC H  
CSI ?5 W  
CSI n I  
CSI n Z  
CSI 2W  
CSI 5W  
Same  
Same  
Same  
Same  
Same  
CTRL I  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Controlling Scrolling  
Smooth scrolling on  
Jump scrolling on  
CSI ?4 h  
CSI ?4 l  
CSI 0 z  
CSI 1 z  
CSI 2 z  
CSI 3 z  
CSI 4 z  
Same  
Same  
Set 0 lps smooth scrolling speed  
Set 1 lps smooth scrolling speed  
Set 2 lps smooth scrolling speed  
Set 4 lps smooth scrolling speed  
Set 8 lps smooth scrolling speed  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Program function keys  
1. VT100 mode:  
DCS c;kl |  
kc/hc ST  
ESC Q Fn  
"string"  
c
0
1
Clear  
kl  
0
1
Key lock  
Lock key definitions  
Don't lock key definitions  
Clear all key definitions  
Clear keys only as they are redefined  
kc  
12  
13  
14  
15  
16  
17  
Shifted function key  
kc  
18  
19  
20  
21  
23  
24  
Shifted function key  
F7  
F8  
F9  
F10  
F11  
F12  
F1  
F2  
F3  
F4  
F5  
F6  
Download from Www.Somanuals.com.5A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Program function keys  
1. VT100 mode (cont'd):  
DCS c;kl |  
kc/hc ST  
ESC Q Fn  
"string"  
kc  
6
7
8
9
Unshifted function key  
kc  
38  
39  
40  
41  
43  
44  
Unshifted function key  
F7  
F8  
F9  
F10  
F11  
F12  
F1  
F2  
F3  
F4  
F5  
F6  
10  
37  
hc Hexadecimal representation of character string assigned to the function key.  
Note: Multiple function key definitions can be programmed by entering the <kc>/<hc> parameters for each, separated by  
semicolons (;).  
2. Console ANSI mode:  
Redefine keys with string  
Function: Define Specific Programmable Function key or Numeric keypad with String.  
Format: ESC Q Fn “ string “  
Parameters: Fn  
0 - F1  
1 - F2  
2 - F3  
3 - F4  
4 - F5  
5 - F6  
6 - F7  
7 - F8  
8 - F9  
9 - F10  
: - F11  
; - F12  
< - S_F1  
= - S_F2  
> - S_F3  
? - S_F4  
@ - S_F5  
A - S_F6  
B - S_F7  
C - S_F8  
D - S_F9  
E - S_F10  
F - S_F11  
G - S_F12  
H - C_F1  
I - C_F2  
T - C_S_F1  
U - C_S_F2  
V - C_S_F3  
W - C_S_F4  
X - C_S_F5  
Y - C_S_F6  
Z - C_S_F7  
[ - C_S_F8  
\ - C_ S_F9  
] - C_ S_F10  
^ - C_ S_F11  
_ - C_ S_F12  
J - C_F3  
K - C_F4  
L - C_F5  
M - C_F6  
N - C_F7  
O - C_F8  
P - C_F9  
Q - C_F10  
R - C_F11  
S - C_F12  
-----------------------------------------------------------------------------------------------------------------------------------------------------------  
for numeric keypad:  
` - ‘7’ key  
a - ‘8’ key  
b - ‘9’ key  
c - ‘-’ key  
d - ‘4’ key  
e - ‘5’ key  
f - ‘6’ key  
g - ‘+’ key  
h - ‘1’ key  
i - ‘2’ key  
j - ‘3’key  
k - ‘0’ key  
Notes:  
1. The string should not include the delimiter, or unexpected conditions maybe occur.  
2. The defined contents of F1 ~F12 will be transmitted out by keying F1~F12.  
The defined contents of S_F1~S_F12 will be transmitted out by multi-keying the Shift and Function key.  
The defined contents of C_F1~C_F12 will be transmitted out by multi-keying the Ctrl and Function key.  
The defined contents of C_S_F1~C_S_F12 will be transmitted out by multi-keying the Ctrl, Shift and Function key.  
Examples: Define Function Key F1 to the character ABC123: ESC Q 0"ABC123"  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Auxiliary Keypad Modes  
Auxiliary keypad numeric mode on  
Auxiliary keypad application mode on  
ESC >  
ESC =  
Same  
Same  
Download from Www.Somanuals.com.5A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Transmission/Printer Control  
Transmit through cursor position  
Transmit to end of line or end of display  
Send form feed after print screen operation  
No form feed sent after print screen operation  
Print full screen  
Print scrolling region  
Print screen  
Send screen  
Transparent print mode off  
Transparent print mode on  
PR port receive mode off  
PR port receive mode on  
Select parallel printer  
Select serial printer  
Print line  
Send line  
Copy print mode off  
CSI 16 h  
CSI 16 l  
CSI ?18 h  
CSI ?18 l  
CSI ?19 h  
CSI ?19 l  
CSI 0 i or CSI i  
CSI 2 i  
CSI 4 i  
CSI 5 i  
CSI 6 i  
CSI 7 i  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
CSI 8 i  
CSI 9 i  
CSI ?1 i  
CSI ?3 i  
CSI ?4 i  
CSI ?5 i  
CSI 1 |  
CSI 0 |  
ESC 5  
CTRL E  
CTRL S  
CTRL Q  
Copy print mode on  
Transmit form feed after send screen operation  
No form feed after send screen operation  
Send characters at cursor  
Send answerback message  
Suspend transmission  
Resume transmission  
------------------------------------------------------------------------------------------------------------------------------------------------------  
More Terminal Control Commands  
Display screen adjustment pattern  
Sound bell, if enabled  
Abort escape sequence; no character displayed*3  
Abort escape sequence; display reverse question  
mark^  
ESC # 8  
Same  
Same  
Same  
Same  
BEL (CTRL G)  
CAN (CTRL X)  
SUB (CTRL Z)  
Initiate escape sequence  
Next Page  
Preceding Page  
ESC (CTRL []  
CSI U  
CSI V  
Same  
Same  
Same  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Terminal Resets  
Soft terminal reset  
Hard terminal reset  
CSI ! p  
ESC c  
Same  
Same  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Terminal Status Reports  
Request primary attributes report  
Request secondary attributes report  
Respond with current revision  
Request terminal status report  
Respond terminal functioning and ready  
Request cursor position report  
Respond cursor at line l, column c  
Request printer status report  
Respond printer ready  
Respond printer not ready  
Respond printer not connected  
Request function key status report  
Respond key definitions not locked  
Respond key definitions locked  
CSI 0 c or ESC Z  
CSI > 0 c  
CSI > 1; 20; 0c  
CSI 5 n  
CSI 0 n  
CSI 6 n  
CSI l; c R  
CSI ?15 n  
CSI ?10 n  
CSI ?11 n  
CSI ?13 n  
CSI ?25 n  
CSI ?20 n  
CSI ?21 n  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Same  
Download from Www.Somanuals.com.5A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Table 9- Supported VT100, VT220 and Console ANSI Commands, Cont'd  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Command  
----------------------------------------------------------------------  
FUNCTION  
VT100, VT220  
Console ANSI  
------------------------------------------------------------------------------------------------------------------------------------------------------  
Request keyboard status report  
Respond with keyboard language  
CSI ? 26 n  
CSI ? 27; Ps n  
Same  
Same  
Ps  
1
Keyboard Language  
U. S.  
Ps  
6
Keyboard Language  
Spanish  
2
U. K.  
7
Swedish  
3
4
Danish  
German  
8
9
Norwegian  
Italian  
5
French  
------------------------------------------------------------------------------------------------------------------------------------------------------  
*1. More than one mode, but less than 17, may be set with one sequence. Enter multiple numeric parameters separated  
by semicolons (;). However you cannot combine sequences containing "?" with those that don't contain "?", nor can  
you combine sequences ending with "h" with those ending with "l".  
*2. To toggle monitor mode from the keyboard, press CTRL SHIFT 1 (use the 1 on the numeric keypad).  
*3. In VT52 or VT100 modes, displays checkerboard character.  
4.5.2 VT52 Command Guide  
Table 10- VT52 Mode Escape Sequences  
--------------------------------------------------------------------------------------------------------  
Command  
VT52  
--------------------------------------------------------------------------------------------------------  
Move cursor up one line  
Move cursor down one line  
Move cursor right one column  
Move cursor left one column  
Move cursor to home position  
Move cursor up one line with scroll  
Move cursor to line line, column col  
Select graphics character set  
Select U.S. ASCII character set  
Erase from cursor to end of display  
Erase from cursor to end of line  
Print cursor line  
ESC A  
ESC B  
ESC C  
ESC D  
ESC H  
ESC I  
ESC Y line col  
ESC F  
ESC G  
ESC J  
ESC K  
ESC V  
ESC ]  
Print display  
Transparent print mode on  
Transparent print mode off  
Copy print mode on  
ESC W  
ESC X  
ESC ^  
Copy print mode off  
ESC _  
ESC =  
ESC >  
ESC <  
ESC Z  
Keypad application mode on  
Keypad application mode off  
Enter VT100 mode  
Identify terminal  
--------------------------------------------------------------------------------------------------------  
Download from Www.Somanuals.com.5A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.6 Using Printer Server via Ethernet Connection  
Introduction  
In order to send print jobs to a network-based printer, the Ethernet Print Terminal function in the TERMINAL must be used. To  
use this function, the Telnet Terminal communication option described on page 1 is available. For this option to work, an  
Ethernet cable must be connected as described on page 6.  
There are two ways to send the print jobs to a network-connected printer: 1) through LPD protocol, and 2) through TFTP protocol.  
The LPD method is more suitable for printing environments with a large number of users because the LPD  
protocol has a queue process so print jobs will be kept in the print queues in the CPU.  
TFTP does not implement the print queue concept; if the printer port is not ready for accepting new print jobs, TFTP  
will be terminated. Consequently, the user must send the print job again. As a result, the TFTP protocol is suitable for  
printing small jobs, in an environment with a small number of users, or for testing purposes.  
LPD is a built-in printing protocol in the BSD type of UNIX and is also available in most other UNIX systems. With LPD, users do  
not need to install additional software to the CPU to print the jobs. Most implementations of the LPD protocol send out the data file  
before the control file. However, since Ethernet Print Terminal must print the data file immediately upon receiving it, the print  
option specified in the control file cannot take affect.  
To install the printer server function of Ethernet Print Terminal, the first step is Basic setup. Whichever printing protocol will be  
used, it is necessary to run basic setup first. If LPD will be used to print jobs, go through the Setup for LPD procedures. If TFTP  
will be used, go through the Setup for TFTP procedures.  
4.6.1 Basic Setup  
Because the TCP/IP world uses IP addressing to communicate with each other, the purpose of Basic Setup is to assign an  
IP address to the Ethernet Print Terminal.  
For the purpose of this explanation, assume the following:  
(1) Login to the UNIX CPU as root  
(2) The Ethernet Print Terminal is on the same network segment that the printer resides.  
Step 1. Add the Print Server to /etc/hosts  
Create a new entry in the /etc/hosts file on all UNIX CPUs that are slated to work with Ethernet Print Terminal.  
To create a new entry, add the following line:  
IP_Address PS_NAME # comment  
where: IP_Address is an IP address.  
PS_NAME is a CPU name of a print server.  
The statement after # is the comment for the new entry.  
e.g. 90.3.2.2 ETPS1 # Ethernet Terminal  
This example assigns the name ETPS1 to the Ethernet Print Terminal with IP address 90.3.2.2.  
NOTE: The IP address is defined in setup Screen of Ethernet Print Terminal, as a Local IP address. Use the same one.  
Step 2. Check to see if above steps are completed  
To verify if the IP address of print Server function is installed successfully, issue the following ping command:  
ping PS_NAME [Enter]  
e.g. ping ETPS1 [Enter]  
Download from Www.Somanuals.com.6A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.6.2 Setup for LPD  
Follow those steps from step 1 to step 2 described in Basic Setup. The following steps are dependent on the operating system.  
Please refer to the UNIX administration guide. The following illustrated steps are under BSD system.  
Step 3. Create a spooling directory  
Use mkdir command to create a directory for spooling.  
e.g. mkdir/usr/spool/ETPS1  
Step 4. Make the directory available to LPD main process  
Basically, the method has the following three procedures:  
1) Assign the spooling daemon as the owner of this directory.  
2) Allow the spooling daemon to be able to read from or write to the directory.  
3) Enable the group of LPD main processes to be able to read from or write to the directory.  
e.g. If it works on a BSD UNIX host and makes the directory /usr/ spool/ETPS1 (created in step 3) available, then follow  
these three procedures:  
chown daemon /usr/spool/ETPS1  
chmod 775 /usr/spool/ETPS1  
chgrp daemon /usr/spool/ETPS1  
Step 5. Add a remote printer  
To add a remote printer, insert a block similar to the following in the /etc/printcap file.  
Printer_name|Remote Printer on Ethernet Terminal:\  
:lp=:\  
:rm=PS_NAME:\  
:rp=Logic_Printer_name:\  
:sd=<full path of spooler directory name>:\  
e.g. If Ethernet Print Terminal works on a BSD UNIX host, then insert the following block into /etc/printcap file.  
ETPS1|Remote Printer on Ethernet Terminal:\  
:lp=:\  
:rm=ETPS1:\  
:rp=L1:\  
:sd=/usr/spool/ETPS1:\  
Step 6. Start CPU's print mechanism for BSD version UNIX system  
Typing: lpc start printer_name [Enter]  
e.g. lpc start ETPS1 [Enter]  
Now the Ethernet Print Terminal is configured to accept LPD printing..  
Download from Www.Somanuals.com.6A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.6.3 LPD printing  
LPD protocol is built-in to most of the UNIX system. However, detailed implementation of LPD differs among UNIX systems.  
Please refer to the UNIX administration guide for reference. The following illustrated printing command is under BSD system or  
System V version.  
For BSD system: lpr -P <printer_name><filename>  
For System V version: lp -d <printer_name><filename>  
This command is to print selected file to the selected printer.  
e.g. lpr -PETPS1 /etc/hosts (BSD version) or lp -dETPS1 /etc/hosts (System V version)  
This example is to print the /etc/hosts file to the Ethernet Print Terminal printer.  
4.6.4 Setup for TFTP  
When working on the BSD UNIX system, run the setup procedure under Setup for LPD on page 61. Otherwise run the Setup for  
LPD omitting step 6.  
4.6.5 TFTP Printing  
Before using TFTP printing, the Ethernet Print Terminal needs to be installed completely by Setup for TFTP (above). TFTP  
Printing lets the user send print jobs to the printers directory. There are no spooling mechanisms involved. Consequently, if that  
printer is not ready, the TFTP process will be terminated immediately without sending print jobs to printers. The user must make  
sure the printer is ready to print before issuing the TFTP command to have a successful result.  
Log into the Ethernet Print Terminal with this command:  
tftp <PS_NAME>  
and then type:  
put <file Name> Ln  
where Ln is a logic printer for L1 to L8  
e.g. tftp ETPS1  
tftp > put /etc/hosts L1  
This example prints the /etc/hosts file to the logic printer 1 of Ethernet Print Terminal printer ETPS1.  
Download from Www.Somanuals.com.6A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.7 On-Screen Display (OSD)  
4.7.1 Standard Controls  
The RACKMUX LCD has 5 standard control buttons and a power LED. The 5 standard control buttons operate as follows:  
The Power button turns the RACKMUX LCD and backlight ON and OFF as desired.  
The Power LED located immediately below the Power button is a dual color  
LED. It will illuminate with a green color when the RACKMUX is powered  
ON and working properly. It will illuminate with a red color if the RACKMUX  
is powered ON but there is no input signal detected. The LED will  
Power  
ON/OFF  
Power LED  
illuminate red only momentarily just before turning OFF.  
Menu  
The Menu button is used to bring up the OSD menu where the various  
settings of the LCD display can be adjusted. Once the OSD screen is  
displayed, the Menu button is used to make selections within the menus.  
See "OSD Control Menu " (below) for more on LCD display settings.  
Up Arrow  
Controls for the  
OSD Menus  
Down Arrow  
The Up and Down Arrow buttons are used to navigate through the  
menus. Move the cursor up or down as desired to highlight an item for  
selection. Once an item is highlighted, pressing the Menu button will  
select it.  
Select/  
Auto Adjust  
Figure 26- OSD Controls  
The Select button is used to make selections within the OSD menus when  
the OSD menu is ON. When the OSD menu is OFF, the Select button will  
act as an Auto Adjust button to keep the user from having to use the menus  
to adjust the quality of the image on the monitor.  
4.7.2 OSD Control Menu  
The OSD (On Screen Display) Menu enables the user to select the desired characteristics of the LCD display. To activate the  
OSD Menu, press the Menu button (above). To turn the Menu back OFF, either select "EXIT" from the main menu or just wait  
10-60 seconds and it will automatically be cleared from the screen.  
4.7.2.1 OSD Main Menu  
Selection  
Brightness/Contrast  
Color  
Purpose  
Range  
1-100  
1-100  
Increase/decrease panel brightness/contrast level  
R,G,B color temperature control  
Position  
Auto Adjust  
1-100  
Video Image horizontal and vertical position control  
Clock setting  
Phase control  
Control OSD Image position on screen  
Set time OSD will stay on screen before auto shutoff  
Select the language of the OSD menu  
Setup  
Exit  
--  
10 to 60 seconds  
Several languages (see page 40)  
Exit from the OSD control menu  
Download from Www.Somanuals.com.6A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.7.2.2 Brightness/Contrast Menu  
Selecting the Brightness/Contrast menu will bring up a screen in which the user can adjust the brightness and contrast levels of  
the LCD display. With either the BRIGHTNESS or CONTRAST sections highlighted, (use the Up or Down arrow to move  
between them), press the Select button to choose the option to adjust. Then use the Up or Down Arrow to adjust the setting.  
Select EXIT when finished to return to the Main Menu.  
4.7.2.3 Color Menu  
Selecting the Color menu will bring up a screen in which the user can adjust the Red, Green, and Blue color levels (values from 1-  
100) of the LCD display. With either the RED, GREEN, or BLUE sections highlighted, (use the Up or Down arrow to move  
between them), press the Select button to choose the option to adjust. Then use the Up or Down Arrow to adjust the setting.  
Select EXIT when finished to return to the Main Menu.  
4.7.2.4 Position Menu  
Selecting the Position menu will bring up a screen in which the user can select AUTO ADJUST to automatically adjust the  
horizontal and vertical position of the displayed image on the monitor, as well as adjust the clock and phase settings if they are not  
correct. The user can also individually adjust these settings if so desired. With either of the sections highlighted, (use the Up or  
Down arrow to move between them), press the Select button to choose the option to adjust. Then use the Up or Down Arrow  
to adjust the setting as needed. Select EXIT when finished to return to the Main Menu.  
.
Download from Www.Somanuals.com.6A4ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.7.2.5 Setup Menu  
Selecting the Setup menu will bring up a screen in which the user can adjust  
ƒ
ƒ
OSD POSITION-the position of the OSD menus on the LCD display  
OSD TIME-the length of time the user can be idle before the OSD menu automatically exits (adjustable from 10  
to 60 seconds)  
ƒ
LANGUAGE-the language that the OSD menus will be presented in  
With the item highlighted, (use the Up or Down arrow to move between them), press the Select button to choose the option to  
adjust. Then use the Up or Down Arrow to adjust the setting as needed. Select EXIT when finished to return to the Main  
Menu.  
OSD Image can be moved  
to different points on the  
display  
Download from Www.Somanuals.com.6A5ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.8 Keyboard Functions  
The keyboard on the RACKMUX has a standard condensed Windows format. To reduce the keyboard size, some keys have  
been assigned multiple functions, accessible via the "Fn" key.  
and how to enable them.  
This section will describe which keys have multiple functions  
NUMLCK  
SCR LCK  
INSERT  
PRT SC  
DELETE  
SYS RQ  
PAUSE  
BREAK  
F2  
F1  
F3  
F6  
F5  
F7  
F8  
F11  
F12  
ESC  
F4  
F9  
F10  
@
&
7
7
(
)
!
#
%
$
^
6
*
+
=
BACKSPACE  
~
`
2
8
9
9
0
1
3
5
4
8
}
]
{
[
T
W
E
R
Y
U
I
O
P
TAB  
Q
\
Enter  
4
5
6
:
;
"
'
ENTER  
CAPS LOCK  
A
S
D
F
G
H
J
K
L
+
1
2
3
*
<
,
?
/
>
.
.
SHIFT  
SHIFT  
Z
X
C
V
B
M
0
N
PG UP  
PG DN  
/
CTRL  
CTRL  
ALT  
ALT  
Fn  
END  
HOME  
"Fn" Key to enable additional key functions  
Figure 27- Keyboard Layout  
Download from Www.Somanuals.com.6A6ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
4.8.1 Number Pad  
The functionality of a Number Pad on a standard Windows keyboard has been incorporated into this keyboard. To  
substitute the keys of the Number Pad  
1
1. Press the "NumLock" key. The NumLock LED (  
2. Press the "Fn" key. This will lock the "Fn" key (until pressed again). The "Fn" LED will illuminate.  
) will illuminate.  
With the Fn and NumLock LEDs illuminated, pressing some standard keys will result in displaying characters as  
indicated in the chart below.  
Table 11- Number Pad Keys  
Standard Key  
Displayed when NumLock is  
Function when NumLock is  
ON  
OFF  
j
“ 1 ”  
End  
k
l
u
“ 2 ”  
“ 3 ”  
“ 4 ”  
Down Arrow  
Page Down  
Left Arrow  
i
“ 5 ”  
o
7
“ 6 ”  
“ 7 ”  
Right Arrow  
Home  
8
9
m
“ 8 ”  
“ 9 ”  
“ 0 ”  
Up Arrow  
Page Up  
Insert  
.
“ . ”  
Delete  
(period)  
(period)  
/
“ / ”  
---  
---  
---  
---  
---  
(forward slash)  
(forward slash)  
“ + ”  
(plus sign)  
;
(semicolon)  
“ * ”  
(asterisk)  
-
(apostrophe)  
-
(hyphen)  
(minus sign)  
ENTER (function)  
[
(left bracket)  
NUMLCK  
SCR LCK  
&
(
*
8
7
9
7
8
9
{
[
U
I
O
Enter  
4
5
6
:
;
"
'
J
K
L
+
1
2
3
*
?
/
>
M
0
.
.
/
Figure 28- Keys of the Number Pad  
Download from Www.Somanuals.com.6A7ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5. HARDWARE INFORMATION  
Introduction  
This chapter provides information on hardware specifications, pinouts for the Ethernet cable, pinouts for port connectors, and  
pinouts for the cable adapters.  
5.1 Hardware Specifications: TERMINAL  
Physical  
Size (In.) WxDxH  
Weight  
19x18.4x1.75  
23.3 lbs.  
Temperature  
Humidity  
0°~38°C operating, -30°~60°C storage  
17% to 96% non condensing  
Auto -ranging 90-262 VAC, 47-63Hz  
60W (max), <25W (standby)  
Power (IEC320), 5 foot DC power supply  
Included for Sun & most EIA 19” racks  
Power Supply  
Power Consumption  
Cables Included  
Rack mount kit  
LCD Panel Specifications  
Screen size  
15.1” visible diagonal  
800x600  
Resolution  
Controls  
Brightness  
contrast, brightness, auto-adjust, color temperature  
250cd/m (typical)  
Contrast  
500:1 (typical)  
Viewing Angle  
Keyboard Specifications  
Type  
140° H / 125° V  
83 key  
US  
Layout  
Terminal Emulation  
Emulations  
VT52, VT100, VT220, Console ANSI, PC TERM, TVI910+/925, WY-50+, WY-60, WY-100, WY-  
120, WY-325, PCG Alpha  
Character matrix  
Screen size  
7x12 dot matrix in 10x16 cell with 3 dot descenders  
80x25  
Page length  
1, 2, or 4 screens (multiple screen page length reduces maximum number of possible telnet  
sessions)  
Cursor  
Blink or steady, block or underline  
Modes  
Color modes  
Full duplex, half duplex, block mode, half block mode  
16 foreground and 16 background colors  
Communication Ports  
Network port  
One RJ45 10Base-T Ethernet port  
Local printer ports  
Serial baud rates  
Data format  
Serial handshake  
Communications options  
One DB25F Parallel and one DB9M RS232 port  
50 to 115,200 bps  
7 or 8 data bits with or without parity, 1 or 2 stop bits  
XON/XOFF, XPC, and hardware DTR  
Single RS232 server connection, or up to 16 Ethernet telnet sessions to predefined IP addresses.  
Both serial and Ethernet connections can not be used concurrently.  
5.2 Hardware Specifications: SERIMUX  
Attribute  
Operating temperature  
Storage temperature  
Humidity  
Power supply External  
Power consumption  
Operating system  
SDRAM  
Value  
40°F to 120°F (5°C to 50°C)  
-20°F to 140°F (-29°C to 60°C)  
10% to 90% non-condensing  
100 - 240VAC, 50/60 Hz, 1.0A (max)  
DC input: 0.8A/5VDC, 4.5 W (typical), 8W (max)  
Linux Hard Hat embedded  
64 megabytes  
Flash memory  
8 megabytes  
Download from Www.Somanuals.com.6A8ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5.3 CPU-to-RACKMUX Ethernet Crossover Cable  
In order to make a direct connection between a CPU and the ETHERNET connector of the RACKMUX, a crossover cable must be  
used. The cable is made with CAT5 cable terminated with RJ45 connectors and wired according to the chart below.  
Pin assignment at  
Wire Color  
Pin assignment at  
Standard End  
Crossed End  
1
2
3
4
5
6
7
8
White/Orange  
Orange  
White/Green  
Blue  
White/Blue  
Green  
White/Brown  
Brown  
3
6
1
4
5
2
7
8
Crossed  
End  
Standard  
End  
Crossover Cable  
5.4 Serial Port Cabling  
The SERIMUX simplifies cabling. The RJ45 8-pin configuration matches all SUN and Cisco RJ45 console port configurations,  
enabling CAT 5 cabling without pinout concerns. Three DB-25 and one DB-9 adapters come in the package. A DB-25 male, a DB-  
25 female, and a DB-9 adapter support console management applications. A DB-25 male adapter provides a modem  
connection. See the cable adapter information that follows later in this chapter.  
Note: The cable length restrictions common to RS-232 cables apply to the SERIMUX serial cable as well.  
5.5 Serial Port Pinouts  
The SERIMUX uses an RJ45 connector for serial ports. Pin assignments are as follows:  
SERIMUX Ports  
Pin  
1
Description  
CTS  
T
R T  
R
R
T
T R  
2
3
DSR  
RxD  
2
-
1
+
3
+
4
-
6
-
7
+ -  
5
+
8
4
GND  
5
DCD: Note Inbound signal can also be used as a second ground.  
6
7
8
TxD  
DTR  
RTS  
Mating face of an RJ45 Female  
Download from Www.Somanuals.com.6A9ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5.6 Cable Adapters  
The SERIMUX comes with four cable adapters. The following illustrations show cable adapter pin outs. Additional adapters can be  
purchased from NTI.  
DB-25 Male Console Adapter (NTI P/N DB25M-RJ45F-T)  
DB-25 Male to RJ45 Connector Pin Assignments  
RJ45  
Signal  
CTS  
DSR  
DCD  
RxD  
DB-25M  
4
Signal  
RTS  
1
2
5
3
Connected to  
Connected to  
20  
DTR  
Connected to  
Connected to  
Connected to  
2
7
TxD  
4
6
GND  
TxD  
GND  
3
6
8
5
RxD  
DCD  
DSR  
CTS  
7
8
DTR  
RTS  
Connected to  
Connected to  
DB-9 Female Console Adapter (NTI P/N DB9F-RJ45F)  
DB-9 Female to RJ45 Pin Assignments  
RJ45  
Signal  
CTS  
DSR  
DCD  
RxD  
DB-9F  
7
Signal  
RTS  
1
2
5
3
4
6
Connected to  
Connected to  
4
DTR  
Connected to  
Connected to  
Connected to  
3
5
2
1
6
8
TxD  
GND  
TxD  
GND  
RxD  
DCD  
DSR  
CTS  
7
8
DTR  
RTS  
Connected to  
Connected to  
Download from Www.Somanuals.com.7A0ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
DB-25 Female Console Adapter (NTI P/N DB25F-RJ45F)  
DB-25 Female to RJ45 Pin Assignments  
RJ45  
Signal  
CTS  
DSR  
DCD  
RxD  
DB-25F  
4
Signal  
RTS  
1
2
5
3
4
6
Connected to  
Connected to  
20  
DTR  
Connected to  
Connected to  
Connected to  
2
7
3
6
8
5
TxD  
GND  
TxD  
GND  
RxD  
DCD  
DSR  
CTS  
7
8
DTR  
RTS  
Connected to  
Connected to  
DB-25 Male Modem Adapter (NTI P/N DB25M-RJ45F-C)  
DB-25 Male Modem to RJ45 Pin Assignment  
RJ45  
Signal  
CTS  
DSR  
RxD  
GND  
DCD  
TxD  
DB-25M  
Signal  
CTS  
DSR  
RxD  
GND  
DCD  
TxD  
1
2
3
4
5
6
Connected to  
Connected to  
Connected to  
Connected to  
Connected to  
Connected to  
5
6
3
7
8
2
7
8
DTR  
RTS  
Connected to  
Connected to  
20  
4
DTR  
RTS  
5.7 SERIMUX Ethernet Pinouts  
The SERIMUX uses a standard Ethernet connector for device connections, that is a shielded and compliant with AT&T 258  
specifications.  
Pin  
1
Description  
Tx+  
2
Tx-  
3
4
Rx+  
NC  
5
NC  
6
Rx-  
7
NC  
8
NC  
Download from Www.Somanuals.com.7A1ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5.8 TERMINAL Connector Pin Assignments  
Serial Port (Serial 2) Connector Pin Assignments  
(RS232C 9-pin connector)  
Pin  
1
2
Signal  
Data carrier detect  
Receive data  
Mnemonic Direction  
DCD In  
RxD In  
1
3 4 5  
2
3
4
5
6
7
8
Transmit data  
Data terminal ready  
Signal ground  
Data set ready  
Request to send  
Clear to send  
TxD Out  
DTR Out  
SGND  
DSR In  
RTS Out  
CTS In  
6
8
9
7
Mating Face  
of 9D Male  
Printer Port Connector Pin Assignments  
(Compatible with the IBM PC parallel port)  
Pin  
1
2
3
4
5
6
7
8
Signal  
-Strobe  
Mnemonic Direction  
Out  
Out  
Out  
Out  
Out  
Out  
Out  
Out  
Out  
In  
In  
In  
In  
Out  
In  
Data bit 0  
Data bit 1  
Data bit 2  
Data bit 3  
Data bit 4  
Data bit 5  
Data bit 6  
Data bit 7  
-Acknowledge  
Busy  
Paper end  
Slct  
-Auto feed XT  
-Error  
-Init  
-Slctn  
13  
25  
1
14  
SUB-D 25  
female connector  
9
10  
11  
12  
13  
14  
15  
16  
17  
18-25  
Out  
Out  
Out  
Ground  
Ethernet Connector Pin Assignments  
(RJ45 8 pin female connector)  
T
R T  
R
R
T
T R  
Pin  
1
2
3
6
Signal  
Direction  
2
-
1
+
3
+
4
-
6
-
7
+ -  
5
+
8
Transmit +  
Transmit -  
Receive +  
Receive -  
Out  
Out  
In  
In  
Mating face of an RJ45 Female  
Download from Www.Somanuals.com.7A2ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
5.9 Dimensional Drawings  
Overhead View of RACKMUX-T15-RS16  
15" LCD Display  
21 .9 IN .  
Keyboard  
Wristpad  
Lock  
PARALLEL  
SERIAL  
ETHERNET  
12VDC CONNECTOR  
RJ45 SERIAL DEVICE CONNECTORS  
Rear View of RACKMUX-T15-RS16  
19 .0 0 IN .  
1.75 IN .  
Front View of RACKMUX-T15-RS16  
Slotted holes for securing terminal drawer to rack  
Side View of RACKMUX-T15-RS16  
Download from Www.Somanuals.com.7A3ll Manuals Search And Download.  
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH  
INDEX  
access to ports, 22  
Administrator password, 23  
ASCII commands, 41  
BSD UNIX system, 62  
cable adapters, 70  
cabling, 69  
change administrator password, 23  
Configure the terminal, 8  
connect to SERIMUX.  
connectors, 6  
Number Pad, 67  
OSD menus, 63  
password, 11  
port access, 22  
Port List, 13  
Port serial settings, 16  
port settings, 14  
printer connection, 6  
programmable keys, 36  
quick start, 8  
Console Terminal, 1  
control buttons, 63  
crossover cable, 69  
Crossover cable, 7  
Default settings, 9,30, 33  
dimensional drawings, 73  
ENH, 41  
Remote System Control, 1  
reset button, 4, 30  
ROOT, 12  
RS-232 Emulations, 1  
setup directory, 8  
Specifications, 68  
SSH Console Switch, 2  
SUN Microsystems, 1  
telnet, 1  
terminal drawer, 1  
TERMINAL setup, 8, 32  
Terse mode, 29  
TFTP printing, 62  
user list, 20  
User main menu, 27  
user settings, 21  
VT100, 52  
Ethernet, 7  
Ethernet Print Terminal, 60  
Firmware menu, 24  
Fn key, 66  
host list, 26  
keyboard, 66  
Keyboard commands, 40  
LAN, 7  
login, 11, 12  
login-user, 26  
LPD method, 60  
VT220, 52  
materials supplied, 3  
Modem settings, 18  
mount to a rack, 5  
VT52, 59  
Wyse, 41  
WARRANTY INFORMATION  
The warranty period on this product (parts and labor) is one (1) year from the date of purchase. Please contact Network  
Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com for  
information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.  
MAN081 Rev. 2/7/07  
Download from Www.Somanuals.com.7A4ll Manuals Search And Download.  

Miele Washer Dryer WT2789iWPM User Manual
Murray Lawn Mower 405628x51A User Manual
Nautique Boat 210 User Manual
Navman GPS Receiver Smart 2005 User Manual
Nikon Camera Lens 35mm f 18G User Manual
Nortel Networks Cordless Telephone IP Phone 1535 User Manual
Optoma Technology Projector TS725 User Manual
Oregon Scientific Automobile Accessories WS912 User Manual
Panasonic Digital Camera DMC FX37 User Manual
Panasonic Telephone KXTG6311 User Manual