National Instruments Digital Camera Smart Camera User Manual |
UNSIERSGmUIDaErt Camera I/O Accessory
This document describes the features of the NI Smart Camera I/O Accessory, what you need to get
started, installation and operation instructions, and accessory specifications.
The NI Smart Camera I/O Accessory features the following:
•
•
•
•
•
•
•
Spring terminals for two isolated inputs
Spring terminals for two isolated outputs
Two power connection options
An RS-232 connector to communicate with the smart camera serial port
User-replaceable fuses for isolated outputs, RS-232, and accessory power
Built-in DIN rail clips for easy mounting
Figure 1 shows the accessory circuit board parts locator diagram.
1
2
3
12
13
14
15
4
5
NATIONAL
INSTRUMENTS
NI SMART CAMERA
I/O ACCESSORY
18
11
10
9
8
7
6
17
16
1
2
3
4
5
6
Camera D-SUB Connector
RS-232 D-SUB Connector
24 VDC D-SUB Connector
Power In Selection Switch
24VDC Two-Position Connector
Isolated Output 1 Terminals
7
8
9
Isolated Output 0 Terminals
Quadrature Encoder Phase B Terminals
Quadrature Encoder Phase A Terminals
13 Power Fuse
14 Spare RS-232 Fuse
15 RS-232 Fuse
16 Isolated Output 0 Fuse
17 Spare Isolated Output Fuses
18 Isolated Output 1 Fuse
10 Isolated Input 1 Terminals
11 Isolated Input 0 Terminals
12 Spare Power Fuse
Figure 1. Front and Back Views of the NI Smart Camera I/O Accessory Circuit Board
Download from Www.Somanuals.com. All Manuals Search And Download.
Operate the device only at or below Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or
gaseous state that can reduce dielectric strength or surface resistivity. The following is a description of
pollution degrees:
•
•
•
Pollution Degree 1 means no pollution or only dry, nonconductive pollution occurs. The pollution
has no influence.
Pollution Degree 2 means that only nonconductive pollution occurs in most cases. Occasionally,
however, a temporary conductivity caused by condensation must be expected.
Pollution Degree 3 means that conductive pollution occurs, or dry, nonconductive pollution occurs
that becomes conductive due to condensation.
You must insulate signal connections for the maximum voltage for which the device is rated. Do not
exceed the maximum ratings for the device. Do not install wiring while the device is live with electrical
signals. Do not remove or add connector blocks when power is connected to the system. Avoid contact
between your body and the connector block signal when hot swapping devices. Remove power from
signal lines before connecting them to or disconnecting them from the device.
Operate the device at or below the installation category1 marked on the hardware label. Measurement
circuits are subjected to working voltages2 and transient stresses (overvoltage) from the circuit to which
they are connected during measurement or test. Installation categories establish standard impulse
withstand voltage levels that commonly occur in electrical distribution systems. The following is a
description of installation categories:
•
•
•
•
Installation Category I is for measurements performed on circuits not directly connected to the
electrical distribution system referred to as MAINS3 voltage. This category is for measurements of
voltages from specially protected secondary circuits. Such voltage measurements include signal
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated
low-voltage sources, and electronics.
Installation Category II is for measurements performed on circuits directly connected to the
electrical distribution system. This category refers to local-level electrical distribution, such as that
provided by a standard wall outlet (for example, 115 AC voltage for U.S. or 230 AC voltage for
Europe). Examples of Installation Category II are measurements performed on household
appliances, portable tools, and similar devices.
Installation Category III is for measurements performed in the building installation at the
distribution level. This category refers to measurements on hard-wired equipment such as
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are
wiring, including cables, bus bars, junction boxes, switches, socket outlets in the fixed installation,
and stationary motors with permanent connections to fixed installations.
Installation Category IV is for measurements performed at the primary electrical supply
installation (<1,000 V). Examples include electricity meters and measurements on primary
overcurrent protection devices and on ripple control units.
1
2
3
Installation categories, also referred to as measurement categories, are defined in electrical safety standard IEC 61010-1.
Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.
MAINS is defined as a hazardous live electrical supply system that powers equipment. Suitably rated measuring circuits may
be connected to the MAINS for measuring purposes.
© National Instruments Corporation
3
NI Smart Camera I/O Accessory User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
To get started with the NI 17xx Smart Camera I/O Accessory, complete the following steps while
referring to Figure 1.
If you have not already installed the NI Smart Camera and required software, refer to Getting Started
with the NI 17xx Smart Camera for instructions.
Note For EMC compliance, operate this device with shielded cables.
Caution Never touch the exposed pins of connectors.
Connect the Camera Cable
Connect the 15-pin D-SUB female to 15-pin D-SUB male cable to the CAMERA connector on the
accessory and to the POWER-I/O connector on the smart camera. Refer to the NI 17xx Smart Camera
User Manual for the POWER-I/O connector pinout and signal information.
Connect the RS-232 Cable (Optional)
and to the serial port on your computer. Refer to the NI 17xx Smart Camera User Manual for
information about configuring and using the serial port of the smart camera.
Connect Signal Wires
Connect the wires to the isolated input, isolated output, and/or quadrature encoder terminal blocks by
stripping 1/4 in. of insulation, pressing on the lever of the spring terminal with a small flathead
screwdriver, and inserting the wire into the terminal. Figure 1 shows the terminal locations. Refer to the
NI 17xx Smart Camera User Manual for information about using isolated inputs, isolated outputs, and
quadrature encoders.
Connect Power
Connect the power using a D-SUB power cable or a custom two-position power cable.
Caution Do not connect input voltages greater than 24 VDC to the NI Smart Camera I/O Accessory.
Input voltages greater than 24 VDC can damage the accessory, all devices connected to it, and the
host computer. National Instruments is not liable for damage or injury resulting from such misuse.
Option A: Using a D-SUB Power Cable
If you are using a power supply other than the NI desktop power supply, refer to the Building a 15-Pin
1. Connect the power supply cord to the 24VDC D-SUB connector on the accessory and to the
connector on the power supply.
2. Move the power in selection switch “up”, towards the 24VDC D-SUB connector.
Option B: Using a Custom Two-Position Power Cable
Refer to the Building a Two-Position Power Cable section for information about building a custom
two-position power cable.
1. Connect the custom two-position power cable to the 24VDC two-position connector on the
accessory and to the connector on the power supply.
2. Move the power in selection switch “down”, towards the 24VDC two-position connector.
NI Smart Camera I/O Accessory User Guide
4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Apply Power
When power is first applied to the smart camera, the POWER LED flashes red for one second while
internal systems power up. The POWER LED then lights green when power is correctly wired to the
smart camera. If the smart camera does not power up, check all connections and the power in selection
switch position, then check the power fuse, as described in the Fuses section.
Building a Custom Power Cable
If you are using a power supply other than the NI desktop power supply, you must build your own power
cable. You can build a power cable with a 15-pin D-SUB connector or the supplied two-position header
connector.
Building a 15-Pin D-SUB Power Cable
You can connect any 24 VDC, +20%/–15% (IEC 1311) power supply to the NI Smart Camera
Caution Do not connect the accessory power to a source other than 24 VDC +20%/–15%
(IEC 1311). Doing so could damage the accessory or the smart camera.
To wire power to a 15-pin D-SUB connector, complete the following steps.
1. Wire the voltage output of the power supply to pin 5 (+24 V) on the D-SUB connector, shown in
Figure 2.
2. Wire the common signal (ground) output of the power supply to pin 15 (COM) on the D-SUB
connector, shown in Figure 2.
15 (COM)
11
6
10
5 (+24 V)
1
Figure 2. 15-Pin D-SUB Pinout
Note Leave all other pins unconnected.
Building a Two-Position Power Cable
The accessory kit ships with a two-position header that plugs directly into the 24V two-position power
input on the accessory. You can build a custom two-position power cable with 16–18 AWG wire, ferrules
(optional), and the two-position header connector (included).
Caution Do not connect the accessory power to a source other than 24 VDC +20%/–15%
(IEC 1311). Doing so could damage the accessory or the smart camera.
To wire power to the two-position connector, complete the following steps.
1. Using wire strippers, carefully remove the insulation from each (16–18 AWG) wire to be connected
to the two-position header. The length of stripped insulation should be 4.3 mm–4.6 mm
(0.17 in.–0.18 in.).
Note If you are using stranded wire, NI recommends that you use ferrules (up to 16 AWG) to protect
the wires from wear due to vibration and strain.
© National Instruments Corporation
5
NI Smart Camera I/O Accessory User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Wire the voltage output of the 24 VDC +20%/–15% (IEC 1311) power supply to the main voltage
input on the two-position connector as shown in Figure 3. Insert a small flathead screwdriver into
the square opening. Using the screwdriver as a lever to open the clamp, insert the wire into the
spring terminal opening. Remove the screwdriver to securely clamp the wire.
COM
+24 VDC
Figure 3. Power Two-Position Header Wiring Diagram
3. Wire the common signal (ground) output of the power supply to the COM signal input on the
two-position connector, shown in Figure 3, using the same technique described in step 2.
Additional power two-position header connectors (part number 734-102) can be ordered from Wago at
Fuses
The NI Smart Camera I/O Accessory has four replaceable fuses. Refer to Figure 1 for the fuse locations.
•
The power fuse (2 A), protects the NI Smart Camera from overcurrent through the +24 VDC
connectors.
•
The other three fuses (200 mA), protect the smart camera from overcurrent through isolated
output 0, isolated output 1, or protect the computer from overcurrent through the ground on the
RS-232 connector.
Testing Fuses
You can check the continuity of the fuse with a handheld DMM. To do this, you must remove the side
panel, as described in steps 1 through 4 of the Replacing Fuses section.
NI Smart Camera I/O Accessory User Guide
6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing Fuses
To replace a blown fuse on the accessory, complete the following steps.
1. Unplug the accessory power.
2. Remove all signal wires and cables from the accessory.
3. Unscrew the two screws from a side panel with a Phillips head screwdriver and remove the side
panel as shown in Figure 4.
NA
ACCESSORTIONAL
NI
SMIANRSTRUMEN
I/O
T
CAMERA
Y
Figure 4. Removing the Circuit Board
4. Slide the circuit board out.
5. Replace the blown fuse while referring to Figure 1 for the fuse location.
Spare fuses can be found next to each fuse location as shown in Figure 1. You also can order
Fuse
Littelfuse Part Number
Description
Power
0448002
2A, 125V lead-free very fast-acting NANO2 subminiature
ceramic surface mount fuse, 6.10 × 2.69 mm
Iso Out 0,
Iso Out 1,
RS-232
0448.200
200mA, 125V lead-free very fast-acting NANO2
subminiature ceramic surface mount fuse, 6.10 × 2.69 mm
© National Instruments Corporation
7
NI Smart Camera I/O Accessory User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
This section lists the specifications of the NI Smart Camera I/O Accessory. These specifications are
typical at 25 °C, unless otherwise noted.
Note Refer to the NI 17xx Smart Camera User Manual for specifications about signals.
Power Requirement
Supply voltage .......................................................24 VDC +20%/–15% (IEC 1311)
Current requirement...............................................Refer to the specification for your NI Smart Camera
Physical
Dimensions ............................................................8.712 cm × 8.509 cm × 4.445 cm
(3.43 in. × 3.35 in. × 1.75 in.)
Weight....................................................................98.1 g (3.46 oz)
Spring terminal blocks...........................................6, 2 positions per block
Wire gauge.....................................................12–28 AWG wire
Camera connector ..................................................15-pin D-SUB male connector
RS-232 connector ..................................................9-pin D-SUB male connector
24VDC connector ..................................................15-pin D-SUB female connector
Environmental
The NI Smart Camera I/O Accessory is intended for indoor use only.
Operating temperature ...........................................0 to 55 °C
Storage temperature ...............................................–20 to 70 °C
Humidity ................................................................10 to 90%, noncondensing
Pollution Degree ....................................................2
Approved at altitudes up to 2,000 m.
Safety
The NI Smart Camera I/O Accessory is designed to meet the requirements of the following standards of
safety for electrical equipment for measurement, control, and laboratory use:
•
•
IEC 61010-1, EN 61010-1
UL 61010-1, CSA 61010-1
Note For UL and other safety considerations, refer to the product label, or visit ni.com/
certification, search by model number or product line, and click the appropriate link in the
Certification column.
NI Smart Camera I/O Accessory User Guide
8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
CE Compliance
The NI Smart Camera I/O Accessory meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
•
•
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory
compliance information. To obtain the DoC for this product, visit ni.com/certification,
search by model number or product line, and click the appropriate link in the Certification column.
Compliance with EU Directives
Users in the European Union (EU) should refer to the Declaration of Conformity (DoC) for information1
pertaining to the CE marking. Refer to the Declaration of Conformity (DoC) for this product for any
additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/
certification, search by model number or product line, and click the appropriate link in the
Certification column.
Environmental Management
National Instruments is committed to designing and manufacturing products in an environmentally
responsible manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment Web page at
ni.com/environment. This page contains the environmental regulations and directives with which
NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center.
For more information about WEEE recycling centers and National Instruments WEEE initiatives,
visit ni.com/environment/weee.htm.
⬉ᄤֵᙃѻક∵ᶧ
ࠊ ㅵ⧚ࡲ ⊩ ˄Ё ˅
RoHS
ヺড়Ё⬉ᄤֵᙃѻકЁ䰤
ࠊ Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ Ёᅶ᠋
݇Ѣ
DŽ
National Instruments
(RoHS)
Ё
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
RoHS
National Instruments
ni.com/environment/rohs_china
(For information about China RoHS compliance, go to
.)
1
The CE marking Declaration of Conformity contains important supplementary information and instructions for the user or
installer.
© National Instruments Corporation
9
NI Smart Camera I/O Accessory User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Where to Go for Support
The National Instruments Web site is your complete resource for technical support. At
ni.com/supportyou have access to everything from troubleshooting and application development
self-help resources to email and phone assistance from NI Application Engineers.
A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European
Communities using the manufacturer’s declaration of conformity. This system affords the user
protection for electronic compatibility (EMC) and product safety. You can obtain the DoC for your
product by visiting ni.com/certification. If your product supports calibration, you can obtain the
calibration certificate for your product at ni.com/calibration.
National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin,
Texas, 78759-3504. National Instruments also has offices located around the world to help address
your support needs. For telephone support in the United States, create your service request at
ni.com/supportand follow the calling instructions or dial 512 795 8248. For telephone support
outside the United States, contact your local branch office:
Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020,
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511,
France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28,
Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150,
Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886,
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222,
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545
NI Smart Camera I/O Accessory User Guide
10
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legalfor more information about National
Instruments trademarks. Other product and company names mentioned herein are trademarks or trade
names of their respective companies. For patents covering National Instruments products/technology,
refer to the appropriate location: Help»Patents in your software, the patents.txtfile on your
media, or the National Instruments Patent Notice at ni.com/patents.
© 2008 National Instruments Corporation. All rights reserved.
372578A-01
Aug08
Download from Www.Somanuals.com. All Manuals Search And Download.
|