WaveStar ADM 16/1
The 2ꢀ5 Gbps SDH Multiplexer and Transport System
Download from Www.Somanuals.com. All Manuals Search And Download.
· Single network element for
interconnection of STM-16,
STM-4 and STM-1 rings
· TransLAN-functionality
based on ML-PPP at 8 x
10/100 BASE-T for each
circuit pack+
· The system architecture allows
a broad range of applications:
add/drop, terminal, local
cross-connect+
· Support of ETSI
Synchronization Status
Message (SSM) protocol+
· AU-3 / TU-3 to AU-4
conversion+
· Full Time Slot Assignment
(TSA) for port interface signals
and Time Slot Inter-change
(TSI) for through channels+
Figure 2: Basic Architecture of the WaveStar ADM 16/1
· Support of PDH signals: E1, E3
and E4+
· Single product platform for
STM-16 and STM-4
applications+
FEATURES AND BENEFITS
· Support of SONET Signals:
DS-1, DS-3, OC-3 & OC-12+
ne of the main features of
Othe WaveStar ADM 16/1 is
the ability to add/drop and
flexibly cross-connect directly
from the STM-16 level+ Signals
that can be connected are: 1+5
(DS-1), 2 (E1), 34 (E3), 45 (DS-
3), 51+8 (STM-0), 140 (E4),
155 (STM-1/OC-3) and 622
(STM-4/OC-12) Mbps+ Unique to
the system is that it supports the
advanced protection mechanisms
MS-SPRing, VC-SNC/N and Dual
Node Interconnection as well as
the conventional MSP+ To reduce
overall installation and test time,
pre-fabricated cabling is used+
Summary of main features and
benefits:
· Protection mechanisms
supported: MS-SPRing,
SNC/N, MSP and DNI+
· VC-4, VC-3 and VC-12 cross-
connect capability+
Figure 3: ADM 16/1 open shelf
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4: WaveStar ADM 16/1 Shelf in rack
Download from Www.Somanuals.com. All Manuals Search And Download.
· Support of SDH signals: STM-
0, STM-1, STM-4 & STM-16+
The WaveStar ADM 16/1 supports a
large variety of configurations for
various network applications (see
Figure 1):
It enables the flexible routing of VC-4,
VC-3 and VC-12 between:
· Aggregate and aggregate+
· Aggregate and tributary+
· Tributary and tributary+
· Mixing of various payload
types+
· Terminal for point-to-point
connections+
· In-shelf optical booster or
booster/pre-amplifier+
· Ring add/drop multiplexer or
STM-4 and 16 rings+
To contribute to overall system
reliability and availability, the
Cross-Connect can be protected
by an accompanying unit+ If
required, interface redundancy
can be provided+ The flexible
design of the WaveStar ADM
16/1 makes it possible to place
interface units in almost any
interface slot position of the
subrack+ The System Controller
(SC) unit controls all major
functions of the WaveStar ADM
16/1 and communicates with the
centralized management system
(ITM)+ Communication is
· Remote maintenance and
management by Lucent
Technologies ITM network
management system+
· Access mux to DWDM, 10G,
cross-connect & SONET+
· Hub mux of STM-1 and STM-4
rings to STM-16+
· Compact self-supporting single
shelf design and easy
installation+
· Grooming of lower-order VCs+
· PDH front-end for digital cross-
connect systems+
· Duplication of critical circuit
racks in the shelf+
· Single ADM 16/1 for
interconnection of STM-16,
STM-4 and STM-1 rings
(Ring Closure on tributary
side)+
APPLICATIONS
he WaveStar ADM 16/1 is a
Tsingle product platform for
STM-16, STM-4 and STM-1
applications+ Based on its
flexibility with regard to interface
units and cross-connect
capabilities, the system supports
applications for bandwidth
access, service-on-demand and
network protection+
established via the Data
· TransLAN-functionality for
10/100 BASE-T Ethernet
signals+
Communication Channels within
the STM-N section overhead
signals or via one of the Q-
interfaces of the system+ The
ITM-SC manages the WaveStar
ADM 16/1 at the element level
and the ITM-NM can manage the
system at the network level+ The
ITM-Craft Interface Terminal
(ITM-CIT) is used for managing
small networks and for
Traffic can be protected by:
· Path protection: VC-n SNC/N+
· Section protection:
The WaveStar ADM 16/1 can be
applied in two tiers of the
network: access & regional
networks+ The system allows for
growth and changing service
needs by supporting in-service
conversions and upgrades+
Inherent to its basic design, the
WaveStar ADM 16/1 operates
equally well within fully
- MS-SPRing, MSP+
· Dual Node Interconnection
(DNI)+
maintenance purposes+
PRODUCT DESCRIPTION
The system is synchronized by an
optionally duplicated Power and
Timing generator circuit pack+
Both 2048-kHz and 2048-kbps
synchronization interfaces are
supported+ References can be
selected by and prioritized from
among the synchronization
interfaces, STM-N interfaces and
2-Mbps tributary interfaces+
Reference protection is possible
by enabling the ETS 300 417-6
compliant synchronization
message protocol which uses the
S1-byte information (SSM
support)+
his flexible product resulted
Tfrom a big step forward in
technology+ Due to the high level
of integration at the circuit pack
level, it is possible to add/drop up
to 504 x E1/DS1, 48 x E3,
synchronous as well as
asynchronous environments and
provides a flexible link between
the two+
64 x 10/100 BASE-T, 96 x
DS3/STM-0, 32 x E4/STM-1/OC-
3 or 8 x STM-4/OC-12 using only
one subrack+ One rack with a
height of 2400 and 2600 mm,
can accommodate two subracks+
The heart of the WaveStar ADM
16/1 system is the Cross-
Connect, which has connections
with all interface cards (see
Figure 2)+ The Cross-Connect is
the core of the system+
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Interfaces
Compliant with the ITU-T Recommendations:
General
Equipment
Physical interface
G+707 (includes G+708 and G+709)
G+781, G+782, G+783, G+784, G+813
G+957 & G+691 for optics and G+703 for
electrical interfaces+
Performance requirements
Mapping Structure
G+823, G+825, G+826
AU4, AU-3 to TU-3, TU-3 & TU-12
(TU-11), VC-4, VC-3 and VC-12
Electrical Interfaces
1+5 Mbps a-synchronous/byte-synchronous
2 Mbps a-synchronous/byte-synchronous
34 / 45-Mbps and 45 Mbps a-synchronous
140 Mbps/STM-1 electrical intra-station
63 (DS-1) interfaces per circuit pack
63 (E1) interfaces per circuit pack
12 (E3/DS-3) interfaces per circuit pack
4 (E4/STM-1) interfaces per circuit pack
Optical Interfaces
Ethernet 10/100 BASE-T & (ML-PPP) 8 interfaces per circuit pack
STM-0 (51840 kbps) interface
12 x interfaces per circuit pack
STM-1/OC-3 (155520 kbps) interface
4 x (S-1+1 & L-1+2) interfaces per circuit
pack
STM-4/OC-12 (622080 kbps) interface
STM-16 (2 488 320 kbps) interfaces
1 x (S-4+1 & L-4+2) interface per circuit
pack
1 x (L-16+1, L-16+2 & L-16+3) interface
per circuit pack
Optical Booster/Pre-amplifier
Optical Booster
OLS 80G (DWDM) interworking
1 x (U-16+2/3) interface per circuit pack
1 x (V-16+2/3) interface per circuit pack
1 x interface per circuit pack, 16 different
wavelengths (1549 - 1559 nm )
1x interface per circuit pack, 80 different
wavelengths (1530 - 1565 nm )
OLS 400G (DWDM) Interworking
Data interfaces:
Six user selectable datachannels
User can select out of E1, E2, F1, F2
and NU bytes (4xG+703 and 2xV+11)
Two programmable Input/Output
station clock interfaces: 2048 kHz
(G703+10) or 2048 kbps
Standard External clock interfaces
(G703+6), 75 or 120 W
Bandwidth Management
System capacity:
VC-12: 504 x 1+5 Mbps, 504 x 2 Mbps,
VC-3: 48 x 34 Mbps, 96 x 45 Mbps,
96 x STM-0,
VC-4: 32 x 140 Mbps, 32 x STM-1 or
8 x STM-4
Complete VC-4 Cross-connecting
Higher Order Cross-connect size 64 x 64 VC-4
Lower Order Cross-connect currently 16x16 and 32 x 32 VC-4
Fixed Cross-Connect for 0x1 and 0x2 Terminal Applications
Uni & Bi-directional Cross-connecting
Broadcast connections type VC-n
VC-4-4c Continuos Concatenation
Higher Order and Lower Order broadcast functionality 1:N (N£9)
Protection access (LPT) on
Scalable MS-SPRing
Drop & Continue
MS-SPRing
Performance requirements
Jitter on STM-N interfaces
Jitter on PDH interfaces
Error Performance
G+813, G+825
G+823, G+783
G+826
Performance monitoring
G+784, G+826
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance Monitorings
Trail Termination Points
Equipment
VC-12
VC-3
VC-4
MS-0
MS-1
MS-4
RS-16
MS-16
for each DS1 and E1 port
for each DS3, E3 and STM-0 interfaces
for each E4 interface and on the Cross-Connect
Multiplex Section on the STM-0 interfaces
Multiplex Section on the STM-1 interfaces
Multiplex Section on the STM-4 interfaces
Regenerator Section of the 2+5 Gbps interfaces
Multiplex Section of the 2+5 Gbps interfaces
Non-Intrusive Monitoring
on VC-4, VC-3 & VC-12 trails & VC- 4- 4c
Severity setting for alarms
Enhancements
History bin:
on each TP instance
compliant 24 hr counters Unavailable period storage
every 15 minutes (16 bins + 4 hour storage time)
Every 24 hours (1 bin + 1 day storage time)
Threshold reports
Supervision and alarms
Plug-in circuit pack Indication
LED continuously on: diagnostic error
LED flashing: transmission signal error
System Controller indicators/buttons:
LED indicators
Power, Prompt and Deferred alarm
Abnormal, Info, Suppressed, UseCIT,
and Disconnect
Push-buttons
Suppress, Disconnect
V+10/RS-232
Floating
8 inputs and 8 outputs
to connect to EMS or other Network
Elements
CIT connector F-interfaces
Station alarm interface outputs
Miscellaneous Discretes
Q-LAN interface
Protection and redundancy
Tributary Level Redundancy:
1:N Equipment protection on 1+5 Mbps & 2 Mbps Interface circuit packs (N= max+ 8)
1+1 Equipment protection on 34/45 Mbps, 45 Mbps Interface circuit packs
1:N Equipment protection on 140/STM1e (N= max+ 4)
1+1 Equipment protection on Cross-connect circuit pack and Power & Timing circuit
pack
SNC/N protection:
VC-4 level
VC-12, VC-3 level
Programmable hold-off times
Dual Node Interworking (DNI):
between two MS-SPRings
between MS-SPRing and LO-SNC protected SubNetworks
Support of VC-4-4c Concatenation
MSP:
1+1 MSP on optical STM-0 (G+783 Annex B), STM-1 (G+783 Annex A & B) and
STM-4 (G+783 Annex A & B) tributary Interface signals
1+1 MSP on optical Line Interface circuit packs STM-16 (G+783 Annex A)
MS-SPRing:
MS-SPRing in two fiber ring Add/Drop applications
Selective MS-SPRing
Cascading of protection schemes in one Network Element
Programmable hold-off times
Maximum of 50 ms switching time for all protection mechanisms
Download from Www.Somanuals.com. All Manuals Search And Download.
Timing and Synchronization
Built-in oscillator Standard
Built-in oscillator Stratum-3
Accuracy 4+6 ppm acc+G+813 option 1
Accuracy 4+6 ppm acc+G813 option 1,
Stability 0+37 ppm/ first 24 hours
Timing modes:
Free running mode
Hold-over mode
Accuracy 4+6 ppm
Locked mode with reference to- one of the external sync+ inputs
- one of the 2 Mbps tributary inputs
- one of the STM-N inputs
Compliant with ETSI ETS 300 417-6
on STM-N interfaces, 2 Mbps and at
2048 kbps external clock interface
on 2 Mbps
Automatic reference signal switching
Support of Synchronization Status Message
Retiming
Network Management
Fully manageable by ITM-NM and ITM-SC
Local Workstation (ITM-CIT) via RJ-45
connections
V+10(RS-232 compatible) / F-interface
Access to Embedded Communication Channels
via in-station Q-LAN interface
G+773-CLNS1 / 10-Base-T and
10-Base-2 Interfaces
ITM-CIT for small network management
CIT-Q connector / V+10
Physical design
This document is for planning purposes
only, and is not intended to modify or
supplement any Lucent Technologies
specifications or warranties relating to
these products or services+
Performance figures and data quoted in
this document are typical and must be
specifically confirmed in writing by
Lucent Technologies before they become
applicable to any particular order or
contract+ The company reserves the right
to make alterations or amendments to
the detailed specifications at its discretion+
Subrack dimensions
750 x 500 x 545 mm (H x W x D)
In accordance with ETSI
Recommendation
Rack Types
ETS 300 119-4 for wide racks
2000 mm Earthquake proof (zone 4)
2200 mm ETSI (D700) rack
2600 mm ETSI (D700) rack
Connectors-Optical
Standard universal build-out optical
connector (FC/PC, SC) on the STM-4
and STM-16 interfaces
LC connectors on STM-0 and LC or SC
connectors on STM-1 interfaces
Choice out of: SUB-D, DIN Coax, APT
Coax, Modular Jack, BT43, ISC 1+5/5+6
RJ-45
Connectors-Electrical
The publication of information in this
document does not imply freedom from
patent or other protective rights of
Lucent Technologies or others+
Connectors-Ethernet
Station power input (Battery)
DC)
-48 or -60 V DC (Range: -40,5+ ++ -72 V
Power Consumption
310 Watt for an average configuration
WaveStar is a trademark of Lucent
Technologies Inc+
Environmental conditions
Acc+ ETSI Requirement Class 3+1 Environment:
3+1 extended (3+1E)
To learn more about our comprehensive
portfolio and the new WaveStar ONG
Series, please contact your Lucent
Technologies Sales Representative
Temperature range
+5°C to + 45°C
0°C to + 50°C
Humidity
Normal operation
Short term operation
Storage-
up to 90%
up to 80%*
up to 100%
25°C to + 55°C
or call +33 49 23 83 333 Visit our web
site at http://www+lucent-optical+com
*Short term conditions last at most 72 hours per year during at most 15 days
EMC
Copyright © 1999 Lucent Technologies+
All Rights Reserved+
Printed in Holland
EC Declaration of Conformity per ETS300 386-1 & -2: "EMC requirements for Public
Telecommunication Network Equipment" which covers:
Radiated emission
Conducted emission
Electro-static discharge
Radiated immunity
Conducted immunity:
- Electrical fast transients
- Surges
EN 55022
EN 55022
IEC 801-2,3,4,
IEC 1000-4-x series
Lucent Technologies Inc+
Marketing Communications
Order Number: PB-025/991102
IEC 1000-4-x series
IEC 1000-4-x series
IEC 1000-4-x series
EN 60950