Lucent Technologies Network Card ADM 16 1 User Manual

WaveStar ADM 16/1  
The 2ꢀ5 Gbps SDH Multiplexer and Transport System  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Single network element for  
interconnection of STM-16,  
STM-4 and STM-1 rings  
· TransLAN™-functionality  
based on ML-PPP at 8 x  
10/100 BASE-T for each  
circuit pack+  
· The system architecture allows  
a broad range of applications:  
add/drop, terminal, local  
cross-connect+  
· Support of ETSI  
Synchronization Status  
Message (SSM) protocol+  
· AU-3 / TU-3 to AU-4  
conversion+  
· Full Time Slot Assignment  
(TSA) for port interface signals  
and Time Slot Inter-change  
(TSI) for through channels+  
Figure 2: Basic Architecture of the WaveStar ADM 16/1  
· Support of PDH signals: E1, E3  
and E4+  
· Single product platform for  
STM-16 and STM-4  
applications+  
FEATURES AND BENEFITS  
· Support of SONET Signals:  
DS-1, DS-3, OC-3 & OC-12+  
ne of the main features of  
Othe WaveStar ADM 16/1 is  
the ability to add/drop and  
flexibly cross-connect directly  
from the STM-16 level+ Signals  
that can be connected are: 1+5  
(DS-1), 2 (E1), 34 (E3), 45 (DS-  
3), 51+8 (STM-0), 140 (E4),  
155 (STM-1/OC-3) and 622  
(STM-4/OC-12) Mbps+ Unique to  
the system is that it supports the  
advanced protection mechanisms  
MS-SPRing, VC-SNC/N and Dual  
Node Interconnection as well as  
the conventional MSP+ To reduce  
overall installation and test time,  
pre-fabricated cabling is used+  
Summary of main features and  
benefits:  
· Protection mechanisms  
supported: MS-SPRing,  
SNC/N, MSP and DNI+  
· VC-4, VC-3 and VC-12 cross-  
connect capability+  
Figure 3: ADM 16/1 open shelf  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4: WaveStar ADM 16/1 Shelf in rack  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Support of SDH signals: STM-  
0, STM-1, STM-4 & STM-16+  
The WaveStar ADM 16/1 supports a  
large variety of configurations for  
various network applications (see  
Figure 1):  
It enables the flexible routing of VC-4,  
VC-3 and VC-12 between:  
· Aggregate and aggregate+  
· Aggregate and tributary+  
· Tributary and tributary+  
· Mixing of various payload  
types+  
· Terminal for point-to-point  
connections+  
· In-shelf optical booster or  
booster/pre-amplifier+  
· Ring add/drop multiplexer or  
STM-4 and 16 rings+  
To contribute to overall system  
reliability and availability, the  
Cross-Connect can be protected  
by an accompanying unit+ If  
required, interface redundancy  
can be provided+ The flexible  
design of the WaveStar ADM  
16/1 makes it possible to place  
interface units in almost any  
interface slot position of the  
subrack+ The System Controller  
(SC) unit controls all major  
functions of the WaveStar ADM  
16/1 and communicates with the  
centralized management system  
(ITM)+ Communication is  
· Remote maintenance and  
management by Lucent  
Technologies ITM network  
management system+  
· Access mux to DWDM, 10G,  
cross-connect & SONET+  
· Hub mux of STM-1 and STM-4  
rings to STM-16+  
· Compact self-supporting single  
shelf design and easy  
installation+  
· Grooming of lower-order VCs+  
· PDH front-end for digital cross-  
connect systems+  
· Duplication of critical circuit  
racks in the shelf+  
· Single ADM 16/1 for  
interconnection of STM-16,  
STM-4 and STM-1 rings  
(Ring Closure on tributary  
side)+  
APPLICATIONS  
he WaveStar ADM 16/1 is a  
Tsingle product platform for  
STM-16, STM-4 and STM-1  
applications+ Based on its  
flexibility with regard to interface  
units and cross-connect  
capabilities, the system supports  
applications for bandwidth  
access, service-on-demand and  
network protection+  
established via the Data  
· TransLAN-functionality for  
10/100 BASE-T Ethernet  
signals+  
Communication Channels within  
the STM-N section overhead  
signals or via one of the Q-  
interfaces of the system+ The  
ITM-SC manages the WaveStar  
ADM 16/1 at the element level  
and the ITM-NM can manage the  
system at the network level+ The  
ITM-Craft Interface Terminal  
(ITM-CIT) is used for managing  
small networks and for  
Traffic can be protected by:  
· Path protection: VC-n SNC/N+  
· Section protection:  
The WaveStar ADM 16/1 can be  
applied in two tiers of the  
network: access & regional  
networks+ The system allows for  
growth and changing service  
needs by supporting in-service  
conversions and upgrades+  
Inherent to its basic design, the  
WaveStar ADM 16/1 operates  
equally well within fully  
- MS-SPRing, MSP+  
· Dual Node Interconnection  
(DNI)+  
maintenance purposes+  
PRODUCT DESCRIPTION  
The system is synchronized by an  
optionally duplicated Power and  
Timing generator circuit pack+  
Both 2048-kHz and 2048-kbps  
synchronization interfaces are  
supported+ References can be  
selected by and prioritized from  
among the synchronization  
interfaces, STM-N interfaces and  
2-Mbps tributary interfaces+  
Reference protection is possible  
by enabling the ETS 300 417-6  
compliant synchronization  
message protocol which uses the  
S1-byte information (SSM  
support)+  
his flexible product resulted  
Tfrom a big step forward in  
technology+ Due to the high level  
of integration at the circuit pack  
level, it is possible to add/drop up  
to 504 x E1/DS1, 48 x E3,  
synchronous as well as  
asynchronous environments and  
provides a flexible link between  
the two+  
64 x 10/100 BASE-T, 96 x  
DS3/STM-0, 32 x E4/STM-1/OC-  
3 or 8 x STM-4/OC-12 using only  
one subrack+ One rack with a  
height of 2400 and 2600 mm,  
can accommodate two subracks+  
The heart of the WaveStar ADM  
16/1 system is the Cross-  
Connect, which has connections  
with all interface cards (see  
Figure 2)+ The Cross-Connect is  
the core of the system+  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
Interfaces  
Compliant with the ITU-T Recommendations:  
General  
Equipment  
Physical interface  
G+707 (includes G+708 and G+709)  
G+781, G+782, G+783, G+784, G+813  
G+957 & G+691 for optics and G+703 for  
electrical interfaces+  
Performance requirements  
Mapping Structure  
G+823, G+825, G+826  
AU4, AU-3 to TU-3, TU-3 & TU-12  
(TU-11), VC-4, VC-3 and VC-12  
Electrical Interfaces  
1+5 Mbps a-synchronous/byte-synchronous  
2 Mbps a-synchronous/byte-synchronous  
34 / 45-Mbps and 45 Mbps a-synchronous  
140 Mbps/STM-1 electrical intra-station  
63 (DS-1) interfaces per circuit pack  
63 (E1) interfaces per circuit pack  
12 (E3/DS-3) interfaces per circuit pack  
4 (E4/STM-1) interfaces per circuit pack  
Optical Interfaces  
Ethernet 10/100 BASE-T & (ML-PPP) 8 interfaces per circuit pack  
STM-0 (51840 kbps) interface  
12 x interfaces per circuit pack  
STM-1/OC-3 (155520 kbps) interface  
4 x (S-1+1 & L-1+2) interfaces per circuit  
pack  
STM-4/OC-12 (622080 kbps) interface  
STM-16 (2 488 320 kbps) interfaces  
1 x (S-4+1 & L-4+2) interface per circuit  
pack  
1 x (L-16+1, L-16+2 & L-16+3) interface  
per circuit pack  
Optical Booster/Pre-amplifier  
Optical Booster  
OLS 80G (DWDM) interworking  
1 x (U-16+2/3) interface per circuit pack  
1 x (V-16+2/3) interface per circuit pack  
1 x interface per circuit pack, 16 different  
wavelengths (1549 - 1559 nm )  
1x interface per circuit pack, 80 different  
wavelengths (1530 - 1565 nm )  
OLS 400G (DWDM) Interworking  
Data interfaces:  
Six user selectable datachannels  
User can select out of E1, E2, F1, F2  
and NU bytes (4xG+703 and 2xV+11)  
Two programmable Input/Output  
station clock interfaces: 2048 kHz  
(G703+10) or 2048 kbps  
Standard External clock interfaces  
(G703+6), 75 or 120 W  
Bandwidth Management  
System capacity:  
VC-12: 504 x 1+5 Mbps, 504 x 2 Mbps,  
VC-3: 48 x 34 Mbps, 96 x 45 Mbps,  
96 x STM-0,  
VC-4: 32 x 140 Mbps, 32 x STM-1 or  
8 x STM-4  
Complete VC-4 Cross-connecting  
Higher Order Cross-connect size 64 x 64 VC-4  
Lower Order Cross-connect currently 16x16 and 32 x 32 VC-4  
Fixed Cross-Connect for 0x1 and 0x2 Terminal Applications  
Uni & Bi-directional Cross-connecting  
Broadcast connections type VC-n  
VC-4-4c Continuos Concatenation  
Higher Order and Lower Order broadcast functionality 1:N (N£9)  
Protection access (LPT) on  
Scalable MS-SPRing  
Drop & Continue  
MS-SPRing  
Performance requirements  
Jitter on STM-N interfaces  
Jitter on PDH interfaces  
Error Performance  
G+813, G+825  
G+823, G+783  
G+826  
Performance monitoring  
G+784, G+826  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Monitorings  
Trail Termination Points  
Equipment  
VC-12  
VC-3  
VC-4  
MS-0  
MS-1  
MS-4  
RS-16  
MS-16  
for each DS1 and E1 port  
for each DS3, E3 and STM-0 interfaces  
for each E4 interface and on the Cross-Connect  
Multiplex Section on the STM-0 interfaces  
Multiplex Section on the STM-1 interfaces  
Multiplex Section on the STM-4 interfaces  
Regenerator Section of the 2+5 Gbps interfaces  
Multiplex Section of the 2+5 Gbps interfaces  
Non-Intrusive Monitoring  
on VC-4, VC-3 & VC-12 trails & VC- 4- 4c  
Severity setting for alarms  
Enhancements  
History bin:  
on each TP instance  
compliant 24 hr counters Unavailable period storage  
every 15 minutes (16 bins + 4 hour storage time)  
Every 24 hours (1 bin + 1 day storage time)  
Threshold reports  
Supervision and alarms  
Plug-in circuit pack Indication  
LED continuously on: diagnostic error  
LED flashing: transmission signal error  
System Controller indicators/buttons:  
LED indicators  
Power, Prompt and Deferred alarm  
Abnormal, Info, Suppressed, UseCIT,  
and Disconnect  
Push-buttons  
Suppress, Disconnect  
V+10/RS-232  
Floating  
8 inputs and 8 outputs  
to connect to EMS or other Network  
Elements  
CIT connector F-interfaces  
Station alarm interface outputs  
Miscellaneous Discretes  
Q-LAN interface  
Protection and redundancy  
Tributary Level Redundancy:  
1:N Equipment protection on 1+5 Mbps & 2 Mbps Interface circuit packs (N= max+ 8)  
1+1 Equipment protection on 34/45 Mbps, 45 Mbps Interface circuit packs  
1:N Equipment protection on 140/STM1e (N= max+ 4)  
1+1 Equipment protection on Cross-connect circuit pack and Power & Timing circuit  
pack  
SNC/N protection:  
VC-4 level  
VC-12, VC-3 level  
Programmable hold-off times  
Dual Node Interworking (DNI):  
between two MS-SPRings  
between MS-SPRing and LO-SNC protected SubNetworks  
Support of VC-4-4c Concatenation  
MSP:  
1+1 MSP on optical STM-0 (G+783 Annex B), STM-1 (G+783 Annex A & B) and  
STM-4 (G+783 Annex A & B) tributary Interface signals  
1+1 MSP on optical Line Interface circuit packs STM-16 (G+783 Annex A)  
MS-SPRing:  
MS-SPRing in two fiber ring Add/Drop applications  
Selective MS-SPRing  
Cascading of protection schemes in one Network Element  
Programmable hold-off times  
Maximum of 50 ms switching time for all protection mechanisms  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Timing and Synchronization  
Built-in oscillator Standard  
Built-in oscillator Stratum-3  
Accuracy 4+6 ppm acc+G+813 option 1  
Accuracy 4+6 ppm acc+G813 option 1,  
Stability 0+37 ppm/ first 24 hours  
Timing modes:  
Free running mode  
Hold-over mode  
Accuracy 4+6 ppm  
Locked mode with reference to- one of the external sync+ inputs  
- one of the 2 Mbps tributary inputs  
- one of the STM-N inputs  
Compliant with ETSI ETS 300 417-6  
on STM-N interfaces, 2 Mbps and at  
2048 kbps external clock interface  
on 2 Mbps  
Automatic reference signal switching  
Support of Synchronization Status Message  
Retiming  
Network Management  
Fully manageable by ITM-NM and ITM-SC  
Local Workstation (ITM-CIT) via RJ-45  
connections  
V+10(RS-232 compatible) / F-interface  
Access to Embedded Communication Channels  
via in-station Q-LAN interface  
G+773-CLNS1 / 10-Base-T and  
10-Base-2 Interfaces  
ITM-CIT for small network management  
CIT-Q connector / V+10  
Physical design  
This document is for planning purposes  
only, and is not intended to modify or  
supplement any Lucent Technologies  
specifications or warranties relating to  
these products or services+  
Performance figures and data quoted in  
this document are typical and must be  
specifically confirmed in writing by  
Lucent Technologies before they become  
applicable to any particular order or  
contract+ The company reserves the right  
to make alterations or amendments to  
the detailed specifications at its discretion+  
Subrack dimensions  
750 x 500 x 545 mm (H x W x D)  
In accordance with ETSI  
Recommendation  
Rack Types  
ETS 300 119-4 for wide racks  
2000 mm Earthquake proof (zone 4)  
2200 mm ETSI (D700) rack  
2600 mm ETSI (D700) rack  
Connectors-Optical  
Standard universal build-out optical  
connector (FC/PC, SC) on the STM-4  
and STM-16 interfaces  
LC connectors on STM-0 and LC or SC  
connectors on STM-1 interfaces  
Choice out of: SUB-D, DIN Coax, APT  
Coax, Modular Jack, BT43, ISC 1+5/5+6  
RJ-45  
Connectors-Electrical  
The publication of information in this  
document does not imply freedom from  
patent or other protective rights of  
Lucent Technologies or others+  
Connectors-Ethernet  
Station power input (Battery)  
DC)  
-48 or -60 V DC (Range: -40,5+ ++ -72 V  
Power Consumption  
310 Watt for an average configuration  
WaveStar is a trademark of Lucent  
Technologies Inc+  
Environmental conditions  
Acc+ ETSI Requirement Class 3+1 Environment:  
3+1 extended (3+1E)  
To learn more about our comprehensive  
portfolio and the new WaveStar™ ONG  
Series, please contact your Lucent  
Technologies Sales Representative  
Temperature range  
+5°C to + 45°C  
0°C to + 50°C  
Humidity  
Normal operation  
Short term operation  
Storage-  
up to 90%  
up to 80%*  
up to 100%  
25°C to + 55°C  
or call +33 49 23 83 333 Visit our web  
*Short term conditions last at most 72 hours per year during at most 15 days  
EMC  
Copyright © 1999 Lucent Technologies+  
All Rights Reserved+  
Printed in Holland  
EC Declaration of Conformity per ETS300 386-1 & -2: "EMC requirements for Public  
Telecommunication Network Equipment" which covers:  
Radiated emission  
Conducted emission  
Electro-static discharge  
Radiated immunity  
Conducted immunity:  
- Electrical fast transients  
- Surges  
EN 55022  
EN 55022  
IEC 801-2,3,4,  
IEC 1000-4-x series  
Lucent Technologies Inc+  
Marketing Communications  
Order Number: PB-025/991102  
IEC 1000-4-x series  
IEC 1000-4-x series  
IEC 1000-4-x series  
EN 60950  
- Continuous wave  
Compliant with LVD  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Radio WA 1140U User Manual
LevelOne Printer FPS 9023 User Manual
Lindy Switch 25010 User Manual
Line 6 Stereo Amplifier Amp User Manual
Line 6 Stereo Amplifier AXSys 212 User Manual
Logitech Mouse M215 User Manual
Mackie Stereo Amplifier M1200 M1400 User Manual
Makita Power Screwdriver 6805BV User Manual
Marantz DVD Player VC5400 User Manual
Martin Audio Stereo Receiver CMX1A User Manual