LG Electronics Air Conditioner 5CSV2 03A User Manual

LG AIR CONDITIONERS  
Ceiling & Floor(50Hz, R22)  
Ceiling Suspended(50Hz, R22)  
5CSV2-03A  
Replaces 5CSV2-02A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Description  
Thank you very much for your special patronage of LG air conditioners.  
LG’s "Ceiling & Floor" and "Ceiling Suspended" are meant both for Commercial and Residential applications.  
The unit can be easily either mounted over ceiling & wall or kept on the floor.  
This has a separate outdoor which facilitates split installation. The capacity ranges from 18k to 60k Btu/h.  
The vertical flow direction of the cooling air can be controlled by remote control, and its low noise design allows  
quite and pleasant cooling.  
Apart from common features, this unit offers some unique features CHAOS Swing, Auto Operation, Healthy  
Dehumidification, Auto Restart, Quiet Operation etc.  
A lot of information regarding the design & installation of this system is provided in this publication. This new  
products series contains data on the same pattern.  
Please utilize all the information for conducting your business efficiently.  
Make sure the specification, dimension or others technical data are same as provided in enginering data book  
before you start the project.  
We look forward to your continuing support.  
LG Electronics Inc.  
Air Conditioning Division  
Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LG Airconditioners Product Data  
TABLE OF CONTENTS  
Table of contents  
Page  
1. Models List ......................................................................................................................4  
2. Model Number Nomenclature ..........................................................................................5  
3 .Feature & Benefits ...........................................................................................................6  
4. List of Functions...............................................................................................................7  
5. Specifications.................................................................................................................12  
6. Dimensional Drawings ...................................................................................................18  
7. Wiring Diagrams.............................................................................................................24  
8. Refrigerant Cycle Diagrams...........................................................................................36  
9. Selection Procedure.......................................................................................................42  
10. Performance Data ........................................................................................................43  
11. The Coefficient of Capacity Change ............................................................................52  
12. Operation Limit.............................................................................................................54  
13. Air Velocity and Temperature Distributions(Reference Data).......................................55  
14. Sound Levels................................................................................................................56  
15. Installation....................................................................................................................58  
16. Function of Remote Controller .....................................................................................86  
Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Models List  
1.1 Cooling Only  
Rated Capacity  
Power Supply  
Ø, V, Hz  
Model  
kW  
5.28  
7.03  
8.21  
kBtu/h  
Refrigerant  
Model Name  
LV-B1864CL  
18  
24  
28  
LV-B2464CL  
1Ø, 220-240V, 50Hz  
LV-B2860CL  
LV-C3681CL  
10.6  
14.1  
17.6  
36  
48  
60  
*LV-C368KLA(B)0  
*LV-C368KLA1  
LV-D4881CL  
R22  
*LV-C488LLA(B)0  
*LV-C488LLA1  
LV-D6081CL  
3Ø, 380-415V, 50Hz  
*LV-C608LLA(B)0  
*LV-C608LLA1  
* : Ceiling suspended type.  
LV-C****LA1 : Tropical model.  
1.2 Heat Pump  
Rated Capacity  
Power Supply  
Ø, V, Hz  
Model  
kW  
5.28  
7.03  
8.21  
kBtu/h  
18  
Refrigerant  
Model Name  
LV-B1864H(B)L  
LV-B2464H(B)L  
LV-B2860HL  
24  
1Ø, 220-240V, 50Hz  
28  
LV-C3681HL  
10.6  
14.1  
17.6  
36  
48  
60  
*LV-H368KLA(B)0  
LV-D4881HL  
R22  
3Ø, 380-415V, 50Hz  
*LV-H488LLA(B)0  
LV-D6081HL  
*LV-H608LLA(B)0  
* : Ceiling suspended type.  
4 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Model Number Nomenclature  
2.1 Identification Rule 1  
-
L V  
B 2 4 6 4 H L  
Option  
L : Basic  
Model Type  
C : Cooling Only  
H : Heat Pump  
B : Heat Pump+Gold Fin  
Development Sequence  
Electrical Rating  
6 : 1Ø, 220-240V, 50Hz  
8 : 3Ø, 380-415V, 50Hz  
Rated Capacity  
Ex) 18 18,000 Btu/h  
24 24,000 Btu/h  
36 36,000 Btu/h  
28 28,000 Btu/h  
48 48,000 Btu/h 60 60,000 Btu/h  
Chassis Name  
B : VB Chassis  
D : VD Chassis  
C : VC Chassis  
Type of Air Conditioner  
LV : LG Ceiling & Floor Type Air Conditioner  
2.2 Identification Rule 2  
-
L V  
C 3 6 8 K L A 0  
Development Sequence  
1 : Tropical model.  
Function  
A : Basic  
B : Low Ambient Control  
Look/Color  
L : Basic  
Chassis Name  
K: VK Chassis  
L : VL Chassis  
Electrical Rating  
8 : 3Ø, 380-415V, 50Hz  
Rated Capacity  
Ex) 36 36,000 Btu/h  
42 42,000 Btu/h  
60 60,000 Btu/h  
48 48,000 Btu/h  
Model Type  
C : Cooling Only  
H : Heat Pump  
Type of Air Conditioner  
LV : LG Ceiling Suspended Type Air Conditioner  
Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Features & Benefits  
Cooling, Heating & Fan Operation :  
- LG Convertible air conditioners can provide cooling, heating & fan operation. In the cooling mode, it cools the  
air with an operation range of 18~30°C. In the heating mode, it heats the air with an operation range of  
16~30°C. In the fan operation mode, only indoor fan at the selected speed will run, outdoor fan and compres-  
sor will be off.  
Auto Restart Operation :  
- When there is electricity failure the system shuts off. After resumption of the power, unit will start in the same  
set conditions prior to the power failure. Memorized condition are on / off condition, operating mode  
(cooling/heating), set temperature and fan speed.  
Hot Start Function :  
- During starting of the unit in the heating mode, it prevents cold air blown from the unit.It starts the indoor fan  
only after indoor unit pipe temperature reaches a preset value(28°C). When indoor unit pipe temperature has  
reached 28°C, then for initial 1 minute the indoor fan runs at low speed and after that at the set fan speed.  
Wireless Remote Control :  
- It provides ease of control.  
Time Delay Safety Function :  
ON  
OFF  
SET  
CANCEL  
- It delays restarting of the compressor by three minutes  
thereby preventing damage to the compressor .  
Low Ambient Control :  
- If the outdoor temperature drops below certain temper-  
ature, liquid back to the compressor is prevented by  
reducing outdoor fan speed. It can prevent frosting of  
evaporator and keep cooling operation on.  
Energy Saving Gold Fin :  
Uncoated Aluminum  
Gold fin  
- Heat Exchanger fins are coated with anticorrosive &  
hydrophilic layers. It prevents the corrosion of heat  
exchanger. Fins remains as new even after long time  
operation and maintains its efficiency.  
It also saves power & maintenance cost.  
Pitting Corrosion  
10mm  
10mm  
Salt Spray Test Result : After 360 hours  
[ Test Standard: ASTM B-117, KS D 9502 ]  
6 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. List of Functions  
Model  
Ceiling & Floor  
LV-B2464H(B)L  
Features  
LV-B1864CL LV-B1864H(B)L LV-B2464CL  
LV-B2860CL  
LV-B2860HL  
Air Discharge outlet  
Airflow Direction control (left & right)  
Airflow Direction control (up & down)  
Airflow Steps(Fan / Cool /Heat)  
Auto Changeover  
1
1
1
1
1
1
Manual  
Auto  
3/3/-  
-
Manual  
Auto  
3/3/3  
-
Manual  
Auto  
3/3/-  
-
Manual  
Auto  
3/3/3  
-
Manual  
Auto  
3/3/-  
-
Manual  
Auto  
3/3/3  
-
Auto Operation  
O
O
O
O
O
O
Auto Restart Operation  
Auto Swing  
O
O
O
O
O
O
O
O
O
O
O
O
Central Control  
-
-
-
-
-
-
CHAOS wind (Auto wind)  
Child Lock Function  
Cooling & Fan Operation  
Coolling, Heating & Fan Operation  
Defrost / Deicing  
O
-
O
-
O
-
-
O
O
-
O
-
O
-
-
O
O
-
O
-
O
-
-
O
-
O
-
O
-
O
Deodorizing Filter  
-
-
-
-
-
-
Drain Pump  
-
-
-
-
-
-
E.S.P. Control  
-
-
-
-
-
-
Electric Heater  
-
-
-
-
-
-
Energy Saving Gold Fin  
Environment Friendly Refrigerant  
Fire Alarm Function  
Forced Operation  
Optional  
Optional  
Optional  
Optional  
Optional  
Optional  
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
Group Control  
-
-
-
-
-
-
High Ceiling Operation  
Hot Start  
-
-
-
O
-
-
-
O
-
-
-
O
Jet Cool  
-
-
-
-
-
-
Low Ambient Control  
Plasma Air Purifier  
Prefilter(Washable / Anti-fungus)  
Restart Delay (3-minutes)  
Self Diagnosis  
Optional  
Optional  
Optional  
Optional  
Optional  
Optional  
-
O
O
O
O
O
-
-
O
O
O
O
O
-
-
O
O
O
O
O
-
-
O
O
O
O
O
-
-
O
O
O
O
O
-
-
O
O
O
O
O
-
Sleep Mode  
Soft Dry Operation  
Comfort Operation With Swirl  
Tele Control  
-
-
-
-
-
-
Temperature Control  
Test Function  
O
-
O
-
O
-
O
-
O
-
O
-
Time Delay Safety Function  
Timer (weekly)  
O
-
O
-
O
-
O
-
O
-
O
-
Timer (24 hr On/Off)  
Two Thermistor Control  
Vane Control  
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
Wired LCD Remote Controller  
Wireless Remote Controller  
Zero Standby Power  
Zone Control  
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
-
-
-
-
-
Notes :  
O : Basic  
Optional : Factory-Installed  
Accessory : Field-Installed  
- : Not available on this system  
Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. List of Functions  
Model  
Ceiling & Floor  
Features  
LV-C3681CL  
LV-C3681HL  
LV-D4881CL  
LV-D4881HL  
LV-D6081CL  
LV-D6081HL  
Air Discharge outlet  
Airflow Direction control (left & right)  
Airflow Direction control (up & down)  
Airflow Steps(Fan / Cool /Heat)  
Auto Changeover  
1
Auto  
Manual  
3/3/-  
-
1
Auto  
Manual  
3/3/3  
-
1
Auto  
Manual  
3/3/-  
-
1
Auto  
Manual  
3/3/3  
-
1
Auto  
Manual  
3/3/-  
-
1
Auto  
Manual  
3/3/3  
-
Auto Operation  
Auto Restart Operation  
Auto Swing  
O
O
O
-
O
O
O
-
O
O
O
-
O
O
O
-
O
O
O
-
O
O
O
-
Central Control  
CHAOS wind (Auto wind)  
Child Lock Function  
Cooling & Fan Operation  
Coolling, Heating & Fan Operation  
Defrost / Deicing  
O
-
O
-
-
-
O
-
-
O
O
-
O
-
O
-
-
-
O
-
-
O
O
-
O
-
O
-
-
-
O
-
-
O
O
-
Deodorizing Filter  
Drain Pump  
-
-
-
-
-
-
E.S.P. Control  
-
-
-
-
-
-
Electric Heater  
-
-
-
-
-
-
Energy Saving Gold Fin  
Environment Friendly Refrigerant  
Fire Alarm Function  
Forced Operation  
-
-
-
O
-
-
-
-
O
-
-
-
-
O
-
-
-
-
O
-
-
-
-
O
-
-
-
-
O
-
Group Control  
High Ceiling Operation  
Hot Start  
Jet Cool  
-
-
-
-
O
-
-
-
-
-
O
-
-
-
-
-
O
-
Low Ambient Control  
Plasma Air Purifier  
Prefilter(Washable / Anti-fungus)  
Restart Delay (3-minutes)  
Self Diagnosis  
-
-
O
O
-
-
-
O
O
-
-
-
O
O
-
-
-
O
O
-
-
-
O
O
-
-
-
O
O
-
Sleep Mode  
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
Soft Dry Operation  
Comfort Operation With Swirl  
Tele Control  
-
-
-
-
-
-
Temperature Control  
Test Function  
O
-
O
-
O
-
O
-
O
-
O
-
Time Delay Safety Function  
Timer (weekly)  
O
-
O
-
O
-
O
-
O
-
O
-
Timer (24 hr On/Off)  
Two Thermistor Control  
Vane Control  
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
Wired LCD Remote Controller  
Wireless Remote Controller  
Zero Standby Power  
Zone Control  
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
O
-
-
-
-
-
-
-
Notes :  
O : Basic  
Optional : Factory-Installed  
Accessory : Field-Installed  
- : Not available on this system  
8 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. List of Functions  
Ceiling Suspended  
Features  
LV-C368KLA0(1)  
LV-H368KLA0  
LV-C368KLB0  
LV-H368KLB0  
Air Discharge outlet  
Airflow Direction control (left & right)  
Airflow Direction control (up & down)  
Airflow Steps(Fan / Cool /Heat)  
Auto Changeover  
1
1
1
1
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Auto Operation  
O
O
O
O
Auto Restart Operation  
Auto Swing  
O
O
O
O
O
O
O
O
Central Control  
-
-
-
-
CHAOS wind (Auto wind)  
Child Lock Function  
Cooling & Fan Operation  
Coolling, Heating & Fan Operation  
Defrost / Deicing  
O
O
O
-
O
O
O
O
O
O
O
-
O
O
O
O
O
O
O
O
Deodorizing Filter  
O
O
O
O
Drain Pump  
-
-
-
-
E.S.P. Control  
-
-
-
-
Electric Heater  
-
-
-
-
Energy Saving Gold Fin  
Environment Friendly Refrigerant  
Fire Alarm Function  
Forced Operation  
Optional  
Optional  
Optional  
Optional  
-
-
O
-
-
O
-
-
O
-
-
O
Group Control  
-
-
-
-
High Ceiling Operation  
Hot Start  
-
-
-
O
-
-
-
O
Jet Cool  
O
O
O
O
Low Ambient Control  
Plasma Air Purifier  
Prefilter(Washable / Anti-fungus)  
Restart Delay (3-minutes)  
Self Diagnosis  
-
-
O
O
-
-
O
O
O
-
O
O
O
-
O
O
O
O
O
O
Sleep Mode  
O
O
O
O
Soft Dry Operation  
Comfort Operation With Swirl  
Tele Control  
O
-
-
O
-
-
O
-
-
O
-
-
Temperature Control  
Test Function  
O
-
O
-
O
-
O
-
Time Delay Safety Function  
Timer (weekly)  
O
O
O
O
O
O
O
O
Timer (24 hr On/Off)  
Two Thermistor Control  
Vane Step Control  
O
O
O
O
Accessary  
Accessary  
Accessary  
Accessary  
-
-
-
-
Wired LCD Remote Control  
Wireless Remote Control  
Zero Standby Power  
Zone Control  
Accessary  
Accessary  
Accessary  
Accessary  
O
O
-
O
O
-
O
O
-
O
O
-
Notes :  
: Basic  
O
Optional : Factory-Installed  
Accessory : Field-Installed  
- : Not available on this system  
Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. List of Functions  
Ceiling Suspended  
Features  
LV-C488LLA0(1)  
LV-H488LLA0  
LV-C488LLB0  
LV-H488LLB0  
Air Discharge outlet  
Airflow Direction control (left & right)  
Airflow Direction control (up & down)  
Airflow Steps(Fan / Cool /Heat)  
Auto Changeover  
1
1
1
1
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Auto Operation  
O
O
O
O
Auto Restart Operation  
Auto Swing  
O
O
O
O
O
O
O
O
Central Control  
-
-
-
-
CHAOS wind (Auto wind)  
Child Lock Function  
Cooling & Fan Operation  
Coolling, Heating & Fan Operation  
Defrost / Deicing  
O
O
O
-
O
O
O
O
O
O
O
-
O
O
O
O
O
O
O
O
Deodorizing Filter  
O
O
O
O
Drain Pump  
-
-
-
-
E.S.P. Control  
-
-
-
-
Electric Heater  
-
-
-
-
Energy Saving Gold Fin  
Environment Friendly Refrigerant  
Fire Alarm Function  
Forced Operation  
Optional  
Optional  
Optional  
Optional  
-
-
O
-
-
O
-
-
O
-
-
O
Group Control  
-
-
-
-
High Ceiling Operation  
Hot Start  
-
-
-
O
-
-
-
O
Jet Cool  
O
O
O
O
Low Ambient Control  
Plasma Air Purifier  
Prefilter(Washable / Anti-fungus)  
Restart Delay (3-minutes)  
Self Diagnosis  
-
-
O
O
-
-
O
O
O
-
O
O
O
-
O
O
O
O
O
O
Sleep Mode  
O
O
O
O
Soft Dry Operation  
Comfort Operation With Swirl  
Tele Control  
O
-
-
O
-
-
O
-
-
O
-
-
Temperature Control  
Test Function  
O
-
O
-
O
-
O
-
Time Delay Safety Function  
Timer (weekly)  
O
O
O
O
O
O
O
O
Timer (24 hr On/Off)  
Two Thermistor Control  
Vane Step Control  
O
O
O
O
Accessary  
Accessary  
Accessary  
Accessary  
-
-
-
-
Wired LCD Remote Control  
Wireless Remote Control  
Zero Standby Power  
Zone Control  
Accessary  
Accessary  
Accessary  
Accessary  
O
O
-
O
O
-
O
O
-
O
O
-
10 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. List of Functions  
Ceiling Suspended  
Features  
LV-C608LLA0(1)  
LV-H608LLA0  
LV-C608LLB0  
LV-H608LLB0  
Air Discharge outlet  
Airflow Direction control (left & right)  
Airflow Direction control (up & down)  
Airflow Steps(Fan / Cool /Heat)  
Auto Changeover  
1
1
1
1
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Manual  
Auto  
3/3/-  
O
Manual  
Auto  
3/4/3  
O
Auto Operation  
O
O
O
O
Auto Restart Operation  
Auto Swing  
O
O
O
O
O
O
O
O
Central Control  
-
-
-
-
CHAOS wind (Auto wind)  
Child Lock Function  
Cooling & Fan Operation  
Coolling, Heating & Fan Operation  
Defrost / Deicing  
O
O
O
-
O
O
O
-
O
O
O
O
O
O
O
O
O
O
O
O
Deodorizing Filter  
O
O
O
O
Drain Pump  
-
-
-
-
E.S.P. Control  
-
-
-
-
Electric Heater  
-
-
-
-
Energy Saving Gold Fin  
Environment Friendly Refrigerant  
Fire Alarm Function  
Forced Operation  
Optional  
Optional  
Optional  
Optional  
-
-
O
-
-
O
-
-
O
-
-
O
Group Control  
-
-
-
-
High Ceiling Operation  
Hot Start  
-
-
-
-
-
O
-
O
Jet Cool  
O
O
O
O
Low Ambient Control  
Plasma Air Purifier  
Prefilter(Washable / Anti-fungus)  
Restart Delay (3-minutes)  
Self Diagnosis  
-
-
O
O
-
-
O
O
O
-
O
O
O
-
O
O
O
O
O
O
Sleep Mode  
O
O
O
O
Soft Dry Operation  
Comfort Operation With Swirl  
Tele Control  
O
-
-
O
-
-
O
-
-
O
-
-
Temperature Control  
Test Function  
O
-
O
-
O
-
O
-
Time Delay Safety Function  
Timer (weekly)  
O
O
O
O
O
O
O
O
Timer (24 hr On/Off)  
Two Thermistor Control  
Vane Step Control  
O
O
O
O
Accessary  
Accessary  
Accessary  
Accessary  
-
-
-
-
Wired LCD Remote Control  
Wireless Remote Control  
Zero Standby Power  
Zone Control  
Accessary  
Accessary  
Accessary  
Accessary  
O
O
-
O
O
-
O
O
-
O
O
-
Notes :  
: Basic  
O
Optional : Factory-Installed  
Accessory : Field-Installed  
- : Not available on this system  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
Item  
Unit  
kcal/h(W)  
Btu/h  
LV-B1864CL  
4536(5275)  
18,000  
LV-B1864H(B)L  
4788(5568)  
19,000  
LV-B2464CL  
6048(7033)  
24,000  
LV-B2464H(B)L  
6048(7033)  
24,000  
Cooling Capacity  
Heating Capacity  
kcal/h(W)  
Btu/h  
-
-
5040(5861)  
20,000  
-
-
6048(7033)  
24,000  
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
1850/-  
9.2/-  
45/-  
1,220~240,50  
1850/1850  
9.2/9.2  
45/45  
1,220~240,50  
91.3  
2450/-  
11.5/-  
67/-  
1,220-240,50  
2670/2570  
12.3/11.9  
45/45  
1,220~240,50  
97  
Running Current  
Starting Current  
Power Supply  
Power Factor  
91.3  
92.3  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
2.45(2.85)  
9.73  
2.59(3.01)  
10.27  
2.72(3.17)  
10.81  
18~30/16~30  
2.5  
Capillary Tube  
1280(45.1),R22  
30  
2.47(2.87)  
2.27(2.63)  
8.99  
2.35(2.74)  
9.34  
18~30/16~30  
3.5  
Capillary Tube  
1390(49.0),R22  
35  
E.E.R  
C.O.P  
9.8  
-
-
18~30/-  
3.5  
-
-
18~30/-  
2.5  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
l/h  
Capillary Tube  
1050(37.0),R22  
30  
Capillary Tube  
1500(53.0),R22  
35  
g(oz), type  
w
Model  
No. of Poles  
IC-9430LGCG  
4
IC-9430LGCG  
4
IC-9430LGCE  
4
IC-9430LGCE  
4
Indoor fan motor  
Input  
Running Current  
Capacitor  
W
A
µF/Vac  
53  
0.23  
1.5/370  
Cross Flow Fan  
1/3.1(80)  
3
53  
0.23  
1.5/370  
63  
0.27  
1.5/370  
Cross Flow Fan  
1/3.1(80)  
3
63  
0.27  
1.5/370  
Type  
Cross Flow Fan  
1/3.1(80)  
3
Cross Flow Fan  
1/3.1(80)  
3
Indoor Fan  
No. Used / Diameter  
Motor Step  
EA/inch(mm)  
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
1090/990/890  
-
1090/990/890  
1090/990/890  
13.5(477)  
43/40/37  
Thermistor  
0.275(7)  
18  
1160/1060/960  
-
1160/1060/960  
1160/1060/960  
15(530)  
45/42/39  
Thermistor  
0.275(7)  
20  
Indoor Fan RPM  
Air Circulation  
13.5(477)  
43/40/37  
Thermistor  
0.275(7)  
18  
15(530)  
45/42/39  
Thermistor  
0.275(7)  
20  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
Tube Size (OD)  
inch(mm)  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
2R 12C  
2R 12C  
2R 14C  
2R 14C  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205)  
30(66.1)  
45  
Rotary  
30(66.1)  
45  
Rotary  
1
30(66.1)  
63  
Rotary  
1
30(66.1)  
67  
Reciprocating  
1
Quantity  
No  
1
Model  
Maker  
Capacity  
2JS318G3AB02  
Matsushita  
19480  
2JS318G3AB02  
Matsushita  
19480  
2J44S235A1A  
Matsushita  
27041  
AWG5532EXC  
Tecumseh  
25496  
Compressor  
Btu/h  
W
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
PSC  
1885  
PSC  
1885  
PSC  
2615  
PSC  
2660  
SUNISO 4GS  
1130  
Internal  
0.375(9.52)  
17  
SUNISO 4GS  
1130  
Internal  
0.275(7)  
18  
AT MOS M60  
1130  
Internal  
0.275(7)  
18  
WITCO LP200  
750  
Internal  
0.275(7)  
18  
cc  
inch(mm)  
Outdoor Coil  
1R 24C  
90  
2R 28C  
90  
2R 28C  
61  
2R 28C  
90  
W
Model  
No. of Poles  
Input  
Running Current  
Capacitor  
IC-1640LGFD  
6
IC-1640LGFD  
6
IC-1640LGFA  
6
IC-1640LGFD  
6
Outdoor fan motor  
W
A
µF/Vac  
170  
0.72  
6/370  
170  
0.72  
6/370  
137  
0.62  
6/370  
170  
0.72  
6/370  
Type  
Propeller  
1/460  
Side Discharge  
850  
Propeller  
1/460  
Side Discharge  
850  
Propeller  
1/460  
Side Discharge  
800  
Propeller  
1/460  
Side Discharge  
850  
No. Used / Diameter  
Discharge  
Speed  
EA/mm  
Side/Top  
rpm  
Outdoor Fan  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
45(1589)  
53  
1 / 4 (6.35)  
1 / 2 (12.7)  
45(1589)  
53  
1 / 4 (6.35)  
1 / 2 (12.7)  
45(1589)  
55  
1 / 4 (6.35)  
5 / 8 (15.88)  
50(1766)  
55  
1 / 4 (6.35)  
5 / 8 (15.88)  
Liquid  
Gas  
Outdoor  
Outdoor  
SVC Valve  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable  
Connecting Cable  
34.2*25.8*12.6(870*655*320) 34.2*25.8*12.6(870*655*320)  
34.2*25.8*12.6(870*655*320) 34.2*25.8*12.6(870*655*320)  
58(127.8)  
2*2.0  
2*2.0  
1 / 4 (6.35)  
1 / 2 (12.7)  
7.5  
60(132.2)  
2*2.0  
(2*2.0)+(2*0.75)  
1 / 4 (6.35)  
1 / 2 (12.7)  
7.5  
58(127.8)  
2*2.0  
2*2.0  
1 / 4 (6.35)  
5 / 8 (15.88)  
7.5  
60(132.2)  
2*2.0  
(2*2.0)+(2*0.75)  
1 / 4 (6.35)  
5 / 8 (15.88)  
7.5  
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
Liquid Side  
Gas Side  
Length, std  
Connecting Tube(Ø. Socket Flare)  
Max length/elevation  
Indoor Unit/Outdoor Unit  
Indoor(W*H*D)  
Outdoor(W*H*D)  
With(Without) S/Parts  
m
mm  
inch(mm)  
inch(mm)  
20/40ft  
15/8  
Ø17/-  
15/8  
Ø17/32  
20/8  
Ø17/-  
20/8  
Ø17/32  
Drain hose(Inner ø)  
Packing Dimension  
50.8*27.4*11.4(1290*696*290) 50.8*27.4*11.4(1290*696*290) 50.8*27.4*11.4(1290*696*290) 50.8*27.4*11.4(1290*696*290)  
40.1*28.1*17.3(1020*715*440) 40.1*28.1*17.3(1020*715*440) 40.1*28.1*17.3(1020*715*440) 40.1*28.1*17.3(1020*715*440)  
Stuffing Quantity  
46/96  
46/96  
46/96  
46/96  
Notes: 1. Capacities are based on the following conditions:  
Cooling:- Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB  
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB  
- Interconnecting Piping Length 7.5m  
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB  
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB  
- Interconnecting Piping Length 7.5 m  
- Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
- Level Difference of Zero.  
12 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
Item  
Unit  
kcal/h(W)  
Btu/h  
LV-B2860CL  
7056(8206)  
28,000  
LV-B2860HL  
7056(8206)  
28,000  
LV-C3681CL  
9072(10551)  
36,000  
LV-C3681HL  
9072(10551)  
36,000  
Cooling Capacity  
kcal/h(W)  
Btu/h  
-
-
7056(8206)  
28,000  
-
-
9072(10551)  
36,000  
Heating Capacity  
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
2850/-  
13.5/-  
85/-  
1,220~240,50  
2850/2850  
13.5/13.5  
85/85  
1,220~240,50  
98  
2810/-  
9.36/-  
46/-  
3,380~415,50  
3,100/2,900  
5.4/5.4  
46/46  
3,380~415,50  
98  
Running Current  
Starting Current  
Power Supply  
Power Factor  
98  
98  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
2.48(2.88)  
9.82  
2.48(2.88)  
9.82  
2.48(2.88)  
9.82  
18~30/16~30  
4
Capillary Tube  
1960(69.1),R22  
40  
3.23(3.75)  
12.81  
2.93(3.40)  
11.61  
3.13(3.64)  
12.41  
18~30/16~30  
2.92  
Capillary Tube  
3600(127.0),R22  
50*2  
E.E.R  
C.O.P  
-
-
-
-
18~30/-  
3.67  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
18~30/-  
l/h  
4
Capillary Tube  
1520(53.6),R22  
40  
Capillary Tube  
3400(120.0),R22  
50*2  
g(oz), type  
w
Model  
No. of Poles  
IC-9430LGCL  
4
IC-9430LGCL  
4
F2-1/15 TY  
4
F2-1/15 TY  
4
Indoor fan motor  
Input  
Running Current  
Capacitor  
W
A
µF/Vac  
81  
0.36  
1.5/370  
Cross Flow Fan  
1/3.1(80)  
3
81  
0.36  
1.5/370  
92*2  
0.37*2  
2.5/400  
92*2  
0.37*2  
2.5/400  
Type  
Cross Flow Fan  
1/3.1(80)  
3
Centrifugal Blower  
4/5.7(144)  
3
Centrifugal Blower  
4/5.7(144)  
3
Indoor Fan  
No. Used / Diameter  
Motor Step  
EA/inch(mm)  
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
1280/1180/1080  
-
1280/1180/1080  
1280/1180/1080  
18(636)  
50/48/46  
Thermistor  
0.275(7)  
20  
1200/1000/800  
-
27.8/22.4/17.0 (982/791/600) 25/23/21 (883/812/742)  
1200/1000/800  
1200/1000/800  
Indoor Fan RPM  
Air Circulation  
18(636)  
50/48/46  
Thermistor  
0.275(7)  
20  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
51/48/42  
Thermistor  
0.375(9.52)  
14  
51/48/45  
Thermistor  
0.375(9.52)  
14  
Tube Size (OD)  
inch(mm)  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
2R 14C  
2R 14C  
3R 10C  
3R 10C  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205) 63.19*27.48*9.25 (1605*698*235) 63.19*27.48*9.25 (1605*698*235)  
30(66.1)  
85  
Reciprocating  
1
30(66.1)  
85  
Reciprocating  
1
65(143.3)  
46  
Scroll  
65(143.3)  
46  
Scroll  
Quantity  
No  
1
1
Model  
Maker  
Capacity  
H25B35QABHA  
Bristol  
H25B35QABHA  
Bristol  
ZR68KC TFD  
Copeland  
34601  
ZR68KC TFD  
Copeland  
34601  
Compressor  
Btu/h  
W
30300  
PSC  
2830  
SUNISO 3GS  
1701  
Internal  
0.275(7)  
18  
2R 28C  
90  
30300  
PSC  
2830  
SUNISO 3GS  
1701  
Internal  
0.275(7)  
18  
2R 36C  
90  
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
-
-
3090  
3090  
WHITE OIL SONTEX 200 LT  
1242  
WHITE OIL SONTEX 200 LT  
1242  
cc  
Internal  
0.375(9.52)  
16  
2R 36C  
149  
Internal  
0.375(9.52)  
16  
2R 36C  
149  
inch(mm)  
Outdoor Coil  
W
Model  
No. of Poles  
Input  
Running Current  
Capacitor  
Type  
No. Used / Diameter  
Discharge  
Speed  
IC-1640LGFD  
6
IC-1640LGFD  
6
CB1-1/5TT-FG  
6
CB1-1/5TT-FG  
6
Outdoor fan motor  
W
A
µF/Vac  
170  
0.72  
6/370  
Propeller  
1/460  
170  
0.72  
6/370  
Propeller  
1/460  
295  
1.56  
295  
1.56  
7.5/400  
Propeller  
1/508  
Side Discharge  
900  
7.5/400  
Propeller  
1/508  
Side Discharge  
900  
EA/mm  
Side/Top  
rpm  
Outdoor Fan  
Side Discharge  
850  
Side Discharge  
850  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
58(2048)  
57  
3 / 8 (9.52)  
5 / 8 (15.88)  
58(2048)  
57  
3 / 8 (9.52)  
5 / 8 (15.88)  
62(2200)  
62  
3/8(9.52)  
3/4(19.05)  
62(2200)  
63  
3/8(9.52)  
3/4(19.05)  
Liquid  
Gas  
Outdoor  
Outdoor  
SVC Valve  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable  
Connecting Cable  
34.2*25.8*12.6(870*655*320) 34.2*31.5*12.6(870*800*320)  
37.4*37.4*14.6(950*950*370) 37.4*37.4*14.6(950*950*370)  
60(132.2)  
2*3.0  
3*0.75  
3 / 8 (9.52)  
5 / 8 (15.88)  
7.5  
62(136.7)  
2*3.0  
4*0.75  
3 / 8 (9.52)  
5 / 8 (15.88)  
7.5  
85(187)  
5*4.0  
6*1.0  
3/8(9.52)  
3/4(19.05)  
5
85(187)  
5*4.0  
6*1.0  
3/8(9.52)  
3/4(19.05)  
5
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
Liquid Side  
Gas Side  
Length, std  
Connecting Tube(Ø. Socket Flare)  
Max length/elevation  
Indoor Unit/Outdoor Unit  
Indoor(W*H*D)  
Outdoor(W*H*D)  
With(Without) S/Parts  
m
mm  
inch(mm)  
inch(mm)  
20/40ft  
25/10  
Ø17/-  
25/10  
Ø17/32  
20/10  
Ø22.22/-  
20/10  
Ø22.22/-  
Drain hose(Inner ø)  
Packing Dimension  
50.8*27.4*11.4(1290*696*290) 50.8*27.4*11.4(1290*696*290) 66.4*31.8*12.4(1686*807*315) 66.4*31.8*12.4(1686*807*315)  
40.1*28.1*17.3(1020*715*440)  
40.1*34.2*17.3(1020*870*440)  
42.9*41.5*17.3(1090*1055*440) 42.9*41.5*17.3(1090*1055*440)  
Stuffing Quantity  
46/96  
42/88  
28/59  
28/59  
Notes: 1. Capacities are based on the following conditions:  
Cooling:- Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB  
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB  
- Interconnecting Piping Length 7.5m  
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB  
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB  
- Interconnecting Piping Length 7.5 m  
- Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
- Level Difference of Zero.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
Item  
Unit  
kcal/h(W)  
Btu/h  
LV-D4881CL  
12096(14067)  
LV-D4881HL  
12096(14067)  
48,000  
LV-D6081CL  
15120(17584)  
LV-D6081HL  
15120(17584)  
60,000  
Cooling Capacity  
Heating Capacity  
48,000  
60,000  
kcal/h(W)  
Btu/h  
-
-
12096(14067)  
48,000  
-
-
15120(17584)  
60,000  
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
4350/-  
11.16/-  
61.8  
3,380~415,50  
4,600/3,600  
8.2/8.2  
61.8  
3,380~415,50  
98  
5,245/-  
15.16/-  
74  
4,900/5,000  
8.6/8.6  
Running Current  
Starting Current  
Power Supply  
Power Factor  
74  
3,380~415,50  
3,380~415,50  
98  
98  
98  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
2.78(3.23)  
10.56  
2.63(3.06)  
10.43  
3.36(3.91)  
13.33  
18~30/16~30  
3.2  
Capillary Tube  
5100(180),R22  
90*2  
2.88(3.35)  
10.72  
3.09(3.59)  
12.24  
3.02(3.52)  
12.00  
18~30/16~30  
3.78  
Capillary Tube  
3900(138),R22  
107*2  
E.E.R  
C.O.P  
-
-
-
-
18~30/-  
5.25  
Capillary Tube  
3800(134),R22  
107*2  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
18~30/-  
3.2  
Capillary Tube  
3690(130.2),R22  
l/h  
g(oz), type  
w
90*2  
Model  
No. of Poles  
F2-1/8 TBT  
F2-1/8 TBT  
4
F2-1/7-TA-FG  
4
F2-1/7-TA-FG  
4
4
Indoor fan motor  
Input  
Running Current  
Capacitor  
W
A
µF/Vac  
150*2  
0.7*2  
3/400  
150*2  
0.7*2  
3/400  
195*2  
0.98*2  
5/400  
195*2  
0.98*2  
5/400  
Type  
Centrifugal Blower  
Centrifugal Blower  
4/6.4(163)  
3
Centrifugal Blower  
4/6.4(163)  
3
Centrifugal Blower  
4/6.4(163)  
3
Indoor Fan  
No. Used / Diameter  
Motor Step  
EA/inch(mm)  
4/6.4(163)  
3
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
1200/1000/800  
-
34.3/27.8/21.3 (1211/982/752) 35/30/25 (1236/1059/883)  
1200/1000/800  
1200/1000/800  
1300/1100/900  
-
34.9/28.6/22.1 (1232/1010/780) 42/35/28 (1483/1236/989)  
1300/1100/900  
1300/1100/900  
Indoor Fan RPM  
Air Circulation  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
52/47/42  
Thermistor  
0.375(9.52)  
14  
56/52/46  
Thermistor  
0.375(9.52)  
14  
55/50/45  
Thermistor  
0.375(9.52)  
14  
58/55/47  
Thermistor  
0.375(9.52)  
14  
Tube Size (OD)  
inch(mm)  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
3R 10C  
75.0*27.48*10.63 (1905*698*270)  
74(163)  
61.8  
3R 10C  
75.0*27.48*10.63 (1905*698*270)  
74(163)  
61.8  
3R 10C  
75.0*27.48*10.63 (1905*698*270)  
81(178)  
74  
3R 10C  
75.0*27.48*10.63 (1905*698*270)  
81(178)  
74  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
Scroll  
Scroll  
Scroll  
Scroll  
Quantity  
No  
1
1
1
1
Model  
Maker  
Capacity  
ZR57KC TFD  
Copeland  
46,426  
ZR57KC TFD  
Copeland  
46,426  
ZR68KC TFD  
Copeland  
55,953  
ZR68KC TFD  
Copeland  
55,949  
Compressor  
Btu/h  
W
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
-
-
-
-
4,160  
WHITE OIL SONTEX 200 LT  
1,650  
4,160  
WHITE OIL SONTEX 200 LT  
1,650  
4,970  
WHITE OIL SONTEX 200 LT  
1,770  
4,970  
WHITE OIL SONTEX 200 LT  
1,770  
cc  
Internal  
0.375(9.52)  
16  
3R 36C  
149  
Internal  
0.375(9.52)  
16  
3R 36C  
149  
Internal  
0.375(9.52)  
16  
2R 46C  
149*2  
Internal  
0.375(9.52)  
16  
2R 46C  
149*2  
inch(mm)  
Outdoor Coil  
W
Model  
No. of Poles  
Input  
Running Current  
Capacitor  
Type  
No. Used / Diameter  
Discharge  
Speed  
CB1-1/5TT-FG  
6
CB1-1/5TT-FG  
6
CB1-1/5TT-FG  
6
CB1-1/5TT-FG  
6
Outdoor fan motor  
W
A
µF/Vac  
295  
1.56  
295  
1.56  
295*2  
1.56*2  
7.5/400  
Propeller  
2/ø508  
295*2  
1.56*2  
7.5/400  
Propeller  
2/ø508  
7.5/400  
Propeller  
1/ø508  
Side Discharge  
900  
7.5/400  
Propeller  
1/ø508  
Side Discharge  
900  
EA/mm  
Side/Top  
rpm  
Outdoor Fan  
Side Discharge  
900  
Side Discharge  
900  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
62(2200)  
63  
1/2(12.7)  
3/4(19.05)  
62(2200)  
63  
1/2(12.7)  
3/4(19.05)  
119(4200)  
64  
119(4200)  
63  
Liquid  
Gas  
Outdoor  
Outdoor  
1/2(12.7)  
3/4(19.05)  
37.4*48.3*14.6(950*1227*370)  
118(260)  
5*4.0  
1/2(12.7)  
3/4(19.05)  
37.4*48.3*14.6(950*1227*370)  
118(260)  
5*4.0  
SVC Valve  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable  
Connecting Cable  
37.4*37.4*14.6(950*950*370) 37.4*37.4*14.6(950*950*370)  
85(187)  
5*4.0  
6*1.0  
1/2(12.7)  
3/4(19.05)  
5
85(187)  
5*4.0  
6*1.0  
1/2(12.7)  
3/4(19.05)  
5
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
6*1.0  
6*1.0  
Liquid Side  
Gas Side  
Length, std  
1/2(12.7)  
3/4(19.05)  
5
1/2(12.7)  
3/4(19.05)  
5
Connecting Tube(Ø. Socket Flare)  
Max length/elevation  
Indoor Unit/Outdoor Unit  
Indoor(W*H*D)  
Outdoor(W*H*D)  
With(Without) S/Parts  
m
mm  
inch(mm)  
inch(mm)  
20/40ft  
25/15  
Ø22.2/-  
25/15  
Ø22.2/-  
30/20  
Ø22.2/-  
30/20  
Ø22.2/-  
Drain hose(Inner ø)  
Packing Dimension  
78.2*31.8*13.9(1986*807*353) 78.2*31.8*13.9(1986*807*353) 78.2*31.8*13.9(1986*807*353) 78.2*31.8*13.9(1986*807*353)  
42.9*41.5*17.3(1090*1055*440) 42.9*41.5*17.3(1090*1055*440) 39.1*50.9*17.0(993*1292*432) 39.1*50.9*17.0(993*1292*432)  
Stuffing Quantity  
22/48  
22/48  
20/45  
20/45  
Notes: 1. Capacities are based on the following conditions:  
Cooling:- Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB  
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB  
- Interconnecting Piping Length 7.5m  
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB  
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB  
- Interconnecting Piping Length 7.5 m  
- Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
- Level Difference of Zero.  
14 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
LV-H368KLA(B)0  
9,072(10,551)  
36,000  
LV-H488LLA(B)0  
11,844(13,774)  
LV-H608LLA(B)0  
13,104(15,240)  
Item  
Unit  
kcal/h(W)  
Btu/h  
Cooling Capacity  
47,000  
52,000  
9,324(10,844)  
37,000  
13,028(15,152)  
14,364(16,705)  
kcal/h(W)  
Btu/h  
Heating Capacity  
51,700  
57,000  
3,470/3,350  
6.3/6.1  
4,790/4,370  
8.0/7.3  
5,670/5,180  
10.0/9.5  
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
Running Current  
Starting Current  
Power Supply  
Power Factor  
-
-
-
3, 380~415, 50  
-
3, 380~415, 50  
3, 380~415, 50  
-
-
2.61(3.04)  
10.37  
2.78(3.24)  
11.0  
18~30/16~30  
3.5  
2.47(2.88)  
9.81  
2.98(3.47)  
11.83  
2.31(2.69)  
9.17  
2.77(3.22)  
11.0  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
°C  
E.E.R  
C.O.P  
18~30/16~30  
18~30/16~30  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
5.8  
capi.  
3,300(116.4), R22  
6.2  
capi.  
3,300(116.4), R22  
l/h  
capi.  
2,640(79.3), R22  
g(oz), type  
w
63  
30  
IC-9430LG58E * 1EA  
4
63  
63  
YDK-090S43513-01 * 1EA  
YDK-090S43513-01 * 2EA  
YDK-090S43513-01 * 2EA  
Model  
No. of Poles  
Input  
Running Current  
Capacitor  
4
140  
0.7  
4
152  
0.67  
4.0/440  
4
152  
0.67  
4.0/440  
Indoor fan motor  
60  
0.28  
4.0/ 440  
W
A
µF/Vac  
4.0/440  
Blower  
4/140(5.5)  
1,377/1,280/1,170 1,420/1,340/1,240  
1,377/1,280/1,170 1,420/1,340/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
1,380/1,310/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
1,380/1,310/1,240  
Type  
Indoor Fan  
No. Used / Diameter  
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
EA/inch(mm)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
Indoor Fan RPM  
Air Circulation  
29/27/24(1,024/953/847)  
33/31/29(1,165/1,094/1,024)  
34/33/31(1,200/1,165/1,094)  
43/41/39  
Thermistor  
54/52/50  
Thermistor  
56/54/52  
Thermistor  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
0.275(7)  
0.275(7)  
0.275(7)  
Tube Size (OD)  
inch(mm)  
17  
3R 14C  
19  
3R 14C  
19  
3R 14C  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
53.2*8.66*25.5(1,350*220*650)  
68.9*8.66*25.5(1,750*220*650)  
68.9*8.66*25.5(1,750*220*650)  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
35(77.2)  
22  
Rotary  
45(99.2)  
47  
Scroll  
45(99.2)  
70  
scroll  
2
1
1
Quantity  
No  
QP325YAA  
SR061YAC  
SR073YAB  
Model  
LG  
LG  
LG  
Maker  
4,838 (19,200)  
12,474(49,500)  
14,742(58,500)  
Compressor  
Capacity  
kcal/hr(Btu/h)  
Three phase induction  
1,778  
NM56/SUNISO 4GSI  
Three phase induction  
Three phase induction  
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
4,500  
SUNISO 4GSI  
1800  
Internal  
0.275(7.0)  
17  
2R 52C  
5,320  
SUNISO 4GSI  
1800  
Internal  
0.275(7)  
17  
2R 52C  
72  
W
cc  
700  
Internal  
0.275(7.0)  
18  
2R 48C  
47.2  
inch(mm)  
Outdoor Coil  
72  
W
OBM-3018P2  
OBM-4006P2  
OBM-4006P2  
Model  
4
6
151  
0.63  
6/370  
6
151  
0.63  
6 / 370  
No. of Poles  
Input  
Running Current  
Capacitor  
Outdoor fan motor  
107.5  
0.48  
2/400  
W
A
µF/Vac  
Propeller  
Propeller  
Propeller  
Type  
2/15.7(400)  
Side Discharge  
2/18.1(460)  
Side Discharge  
2/18.1(460)  
Side Discharge  
No. Used / Diameter  
Discharge  
Speed  
EA/inch(mm)  
Side/Top  
rpm  
Outdoor Fan  
1,040  
880  
880  
64(2,260)  
58  
1/4(6.35)  
5/8(15.88)  
105(3,708)  
60  
3/8(9.52)  
105(3,708)  
62  
3/8(9.52)  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
Liquid  
Gas  
Outdoor  
Outdoor  
SVC Valve  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
34.2*41.7*12.5(870*1,060*320)  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable(With Earth Cable)  
Conncecting Cable(With Earth Cable)  
Liquid Side  
80(176)  
5*3.5  
5*1.25  
1/4(6.35)  
5/8(15.88)  
5
95(209.4)  
5*3.5  
5*1.25  
3/8(9.52)  
3/4(19.05)  
5
95(209.4)  
5*3.5  
5*1.25  
3/8(9.52)  
3/4(19.05)  
5
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
Gas Side  
Connecting Tube(Ø. Socket Flare)  
Length, std  
30/20  
50/30  
30/20  
Max length/elevation  
m
Ø17  
Ø17  
Ø17  
Drain hose(Inner ø)  
Indoor Unit  
mm  
1,450*315*750  
1,060*1,140*440  
50  
1,850*315*750  
1,060*1,220*455  
60  
1,850*315*750  
1,060*1,220*455  
60  
Packing Dimension  
Indoor(W*H*D)  
Outdoor(W*H*D)  
inch(mm)  
inch(mm)  
g
Additional Refrigerant Charge(Over 5m)  
Notes: 1. Capacities are based on the following conditions:  
Cooling: - Indoor Temperature 27˚C(80.6˚F) DB /19˚C(66.2˚F) WB  
-
-
-
Outdoor Temperature 35˚C(95˚F) DB /24˚C(75.2˚F) WB  
Interconnecting Piping Length 5m  
Level Difference of Zero.  
Heating: - Indoor Temperature 20˚C(68˚F) DB / 15˚C(59˚F) WB  
-
-
-
Outdoor Temperature 7˚C(44.6˚F) DB / 6˚C(42.8˚F) WB  
Interconnecting Piping Length 5 m  
Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
LV-C368KLA(B)0  
LV-C488LLA(B)0  
LV-C608LLA(B)0  
Item  
Unit  
9,072(10,551)  
36,000  
11,844(13,774)  
13,104(15,240)  
kcal/h(W)  
Btu/h  
kcal/h(W)  
Btu/h  
Cooling Capacity  
Heating Capacity  
47,000  
-
-
52,000  
-
-
-
-
3,470/-  
6.3/-  
-
4,790/-  
8/-  
-
5,670/-  
10/-  
-
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
Running Current  
Starting Current  
Power Supply  
Power Factor  
3, 380~415, 50  
3, 380~415, 50  
3, 380~415, 50  
-
-
-
2.61(3.04)  
10.37  
2.47(2.88)  
9.81  
2.31(2.69)  
9.17  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
°C  
E.E.R  
C.O.P  
-
-
-
-
-
-
18~30  
3.5  
18~30  
5.8  
capi.  
3,300(116.4), R22  
18~30  
6.2  
capi.  
3,300(116.4), R22  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
l/h  
capi.  
2,640(79.3), R22  
g(oz), type  
w
63  
30  
63  
63  
YDK-090S43513-01 * 1EA  
IC-9430LG58E * 1EA  
YDK-090S43513-01 * 2EA  
YDK-090S43513-01 * 2EA  
Model  
4
140  
0.7  
4
60  
0.28  
4
152  
0.67  
4.0/440  
4
152  
0.67  
4.0/440  
No. of Poles  
Input  
Running Current  
Capacitor  
Indoor fan motor  
W
A
µF/Vac  
4.0/440  
4.0/ 440  
Blower  
4/140(5.5)  
1,377/1,280/1,170 1,420/1,340/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
Type  
Indoor Fan  
No. Used / Diameter  
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
EA/inch(mm)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
Indoor Fan RPM  
Air Circulation  
-
-
-
29/27/24(1,024/953/847)  
33/31/29 (1,165/1,094/1,024)  
34/33/31(1,200/1,165/1,094)  
43/41/39  
Thermistor  
54/52/50  
Thermistor  
56/54/52  
Thermistor  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
0.275(7)  
0.275(7)  
0.275(7)  
Tube Size (OD)  
inch(mm)  
17  
3R 14C  
19  
3R 14C  
19  
3R 14C  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
53.2*8.66*25.5(1,350*220*650)  
68.9*8.66*25.5(1,750*220*650)  
68.9*8.66*25.5(1,750*220*650)  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
35(77.2)  
22  
Rotary  
45(99.2)  
47  
Scroll  
45(99.2)  
70  
scroll  
2
1
1
Quantity  
No  
QP325YAA  
SR061YAC  
SR073YAB  
Model  
LG  
LG  
LG  
Maker  
4,838(19,200)  
12474(49,500)  
14,742(58,500)  
Compressor  
Capacity  
kcal/hr(Btu/h)  
Three phase induction  
Three phase induction  
Three phase induction  
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
1778  
4500  
SUNISO 4GSI  
1800  
Internal  
0.275(7.0)  
17  
2R 52C  
5320  
SUNISO 4GSI  
1800  
Internal  
0.374(9.52)  
17  
2R 52C  
W
cc  
NM56/SUNISO 4GSI  
700  
Internal  
0.275(7.0)  
18  
2R 48C  
47.2  
inch(mm)  
Outdoor Coil  
72  
72  
W
OBM-3018P2  
OBM-4501P2  
OBM-4501P2  
Model  
4
6
151  
0.63  
6/370  
6
151  
0.63  
6/370  
No. of Poles  
Input  
Running Current  
Capacitor  
Outdoor fan motor  
107.5  
0.48  
2/400  
W
A
µF/Vac  
Propeller  
Propeller  
Propeller  
Type  
2/15.7(400)  
Side Discharge  
2/18.1(460)  
Side Discharge  
2/18.1(460)  
Side Discharge  
No. Used / Diameter  
Discharge  
Speed  
EA/inch(mm)  
Side/Top  
rpm  
Outdoor Fan  
1,040  
880  
880  
64(2,260)  
58  
1/4(6.35)  
5/8(15.88)  
105(3,708)  
60  
3/8(9.52)  
105(3,708)  
62  
3/8(9.52)  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
Liquid  
Gas  
Outdoor  
Outdoor  
SVC Valve  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
34.2*41.7*12.5(870*1,060*320)  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable(With Earth Cable)  
Conncecting Cable(With Earth Cable)  
Liquid Side  
80(176)  
5*3.5  
4*1.25  
1/4(6.35)  
5/8(15.88)  
5
95(209.4)  
5*3.5  
4*1.25  
3/8(9.52)  
3/4(19.05)  
5
95(209.4)  
5*3.5  
4*1.25  
3/8(9.52)  
3/4(19.05)  
5
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
Gas Side  
Connecting Tube(Ø. Socket Flare)  
Length, std  
30/20  
50/30  
30/20  
Max length/elevation  
m
Ø17  
Ø17  
Ø17  
Drain hose(Inner ø)  
Indoor Unit  
mm  
1,452*315*750  
1,060*1,140*440  
50  
1,850*315*750  
1,060*1,220*455  
60  
1,850*315*750  
1,060*1,220*455  
60  
Packing Dimension  
Indoor(W*H*D)  
Outdoor(W*H*D)  
inch(mm)  
inch(mm)  
g
Additional Refrigerant Charge(Over 5m)  
Notes: 1. Capacities are based on the following conditions:  
Cooling: - Indoor Temperature 27˚C(80.6˚F) DB /19˚C(66.2˚F) WB  
-
-
-
Outdoor Temperature 35˚C(95˚F) DB /24˚C(75.2˚F) WB  
Interconnecting Piping Length 5m  
Level Difference of Zero.  
Heating: - Indoor Temperature 20˚C(68˚F) DB / 15˚C(59˚F) WB  
-
-
-
Outdoor Temperature 7˚C(44.6˚F) DB / 6˚C(42.8˚F) WB  
Interconnecting Piping Length 5 m  
Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
16 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Specifications  
LV-C368KLA1  
LV-C488LLA1  
LV-C608LLA1  
Item  
Unit  
8,568(9,964)  
34,000  
11,844(13,774)  
13,104(15,240)  
kcal/h(W)  
Btu/h  
Cooling Capacity  
47,000  
52,000  
-
-
-
-
-
-
kcal/h(W)  
Btu/h  
Heating Capacity  
3,200/-  
5.6/-  
-
4,790/-  
8.0/-  
-
5,670/-  
10.0/-  
-
Input  
Cooling/Heating  
Cooling/Heating  
Cooling/Heating  
W
A
A
ø,V,Hz  
%
Running Current  
Starting Current  
Power Supply  
Power Factor  
3, 380~415, 50  
3, 380~415, 50  
3, 380~415, 50  
-
-
-
2.68(3.11)  
10.63  
2.47(2.88)  
9.81  
2.31(2.69)  
9.17  
Cooling  
Heating  
kcal/h W(W/W)  
Btu/h W  
kcal/h W(W/W)  
Btu/h W  
°C  
E.E.R  
C.O.P  
-
-
-
-
-
-
18~30/-  
3.5  
18~30/-  
5.8  
capi.  
3,300(116.4), R22  
18~30/-  
6.2  
capi.  
3,300(116.4), R22  
Setting temperature range(cool/heat)  
Dehumidification Rate  
Refrigerant Control  
Refrigerant charge  
Output  
l/h  
capi.  
2,350(82.9), R22  
g(oz), type  
w
63  
30  
63  
63  
YDK-090S43513-01 * 1 EA  
IC-9430LG58E * 1 EA  
YDK-090S43513-01 * 2 EA  
YDK-090S43513-01 * 2 EA  
Model  
4
140  
0.7  
4
60  
0.28  
4
152  
0.67  
4.0/440  
4
152  
0.67  
4.0/440  
No. of Poles  
Input  
Running Current  
Capacitor  
Indoor fan motor  
W
A
µF/Vac  
4.0/440  
4.0/ 440  
Blower  
4/140(5.5)  
1,377/1,280/1,170 1,420/1,340/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
Blower  
4/140(5.5)  
1,380/1,310/1,240  
Type  
Indoor Fan  
No. Used / Diameter  
Cooling(H/M/L)  
Heating(H/M/L)  
Indoor (H/M/L)  
EA/inch(mm)  
rpm  
rpm  
CMM(CFM)  
dB(A)±3  
Indoor Fan RPM  
Air Circulation  
-
-
-
29/27/24(1,024/953/847)  
33/31/29 (1,165/1,094/1,024)  
34/33/31(1,200/1,165/1,094)  
43/41/39  
Thermistor  
54/52/50  
Thermistor  
56/54/52  
Thermistor  
Noise Level(Sound Press,1m) Indoor(H/M/L)  
Temperature Controller  
0.275(7)  
0.275(7)  
0.275(7)  
Tube Size (OD)  
inch(mm)  
17  
3R 14C  
19  
3R 14C  
19  
3R 14C  
Indoor Coil  
Fins per inch  
No. of Rows & Column  
Indoor  
indoor  
Locked Rotor Amp.  
Type  
53.2*8.66*25.5(1,350*220*650)  
68.9*8.66*25.5(1,750*220*650)  
68.9*8.66*25.5(1,750*220*650)  
Dimensions (W*H*D)  
Net Weight  
inch(mm)  
kg(lbs)  
A
35(77.2)  
36  
Scroll  
45(99.2)  
47  
Scroll  
45(99.2)  
70  
scroll  
1
SQ042YAA  
LG  
1
1
Quantity  
Model  
Maker  
No  
SR061YAC  
SR073YAB  
LG  
LG  
8,686 (34,500)  
Three phase induction  
1,778  
12474(49,500)  
Three phase induction  
14,742(58,500)  
Three phase induction  
Compressor  
Capacity  
kcal/hr(Btu/h)  
Motor Type  
Motor Input  
Oil Type  
Oil Charge  
O.L.P Type(model name)  
Tube Size (OD)  
Fins per inch  
No. of Rows & Column  
Output  
4,500  
SUNISO 4GSI  
1,800  
Internal  
0.275(7.0)  
17  
2R 52C  
5,320  
SUNISO 4GSI  
1,800  
Internal  
0.374(9.52)  
17  
2R 52C  
W
cc  
SUNISO 4GSI  
1,300±10  
Internal  
0.275(7.0)  
18  
inch(mm)  
Outdoor Coil  
2R 48C  
47.2  
72  
72  
W
OBM-3018P2  
4
OBM-4502P2  
OBM-4502P2  
Model  
No. of Poles  
Input  
Running Current  
Capacitor  
6
130  
0.58  
6/370  
6
130  
0.58  
6/370  
Outdoor fan motor  
107.5  
0.48  
2/400  
W
A
µF/Vac  
Propeller  
2/15.7(400)  
Side Discharge  
1,040  
Propeller  
2/18.1(460)  
Side Discharge  
Propeller  
2/18.1(460)  
Side Discharge  
Type  
No. Used / Diameter  
Discharge  
Speed  
EA/inch(mm)  
Side/Top  
rpm  
Outdoor Fan  
820  
820  
64(2,260)  
58  
102(3,602)  
60  
3/8(9.52)  
102(3,602)  
62  
3/8(9.52)  
Air Circulation  
Noise Level(Sound Press,1m) Outdoor  
Outdoor  
CMM(CFM)  
dB(A)±3  
inch(mm)  
inch(mm)  
inch(mm)  
kg(lbs)  
1/4(6.35)  
5/8(15.88)  
34.2*41.7*12.5(870*1,060*320)  
80(176.4)  
5*3.5  
Liquid  
Gas  
Outdoor  
Outdoor  
SVC Valve  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
3/4(19.05)  
35.4*45.6*14.6(900*1,160*370)  
Dimensions (W*H*D)  
Net Weight  
Power Supply Cable(With Earth Cable)  
Conncecting Cable(With Earth Cable)  
Liquid Side  
95(209.4)  
5*3.5  
4*1.25  
3/8(9.52)  
3/4(19.05)  
7.5  
95(209.4)  
5*3.5  
4*1.25  
3/8(9.52)  
3/4(19.05)  
7.5  
No.* mm2  
No.* mm2  
inch(mm)  
inch(mm)  
m
4*1.25  
1/4(6.35)  
5/8(15.88)  
7.5  
Gas Side  
Connecting Tube(Ø. Socket Flare)  
Length, std  
30/20  
50/30  
30/20  
Max length/elevation  
m
Ø17  
Ø17  
Ø17  
Drain hose(Inner ø)  
Indoor Unit  
mm  
1,452*315*750  
1,060*1,140*440  
50  
1,850*315*750  
1,060*1,220*455  
50  
1,850*315*750  
1,060*1,220*455  
50  
Packing Dimension  
Indoor(W*H*D)  
Outdoor(W*H*D)  
inch(mm)  
inch(mm)  
g
Additional Refrigerant Charge(Over 5m)  
Notes: 1. Capacities are based on the following conditions:  
Cooling: - Indoor Temperature 27˚C(80.6˚F) DB /19˚C(66.2˚F) WB  
-
-
-
Outdoor Temperature 35˚C(95˚F) DB /24˚C(75.2˚F) WB  
Interconnecting Piping Length 5m  
Level Difference of Zero.  
Heating: - Indoor Temperature 20˚C(68˚F) DB / 15˚C(59˚F) WB  
-
-
-
Outdoor Temperature 7˚C(44.6˚F) DB / 6˚C(42.8˚F) WB  
Interconnecting Piping Length 5 m  
Level Difference of Zero.  
2. Capacities are Net Capacities.  
3. Due to our policy of innovation some specifications may be changed without notification.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-B1864C(H/B)L, LV-B2464C(H/B)L, LV-B2860C(H)L  
Indoor Unit  
1200mm  
R
205mm  
63mm  
38mm  
175mm  
(Installation Plate)  
250mm  
(Rear Side)  
Outdoor Unit  
W
MODEL  
LV-B1864C(H/B)L  
LV-B2464C(H/B)L LV-B2860C(H)L  
LV-B2860C(H/B)L  
Dim.(mm)  
W
H
D
L1  
L2  
L3  
L4  
L5  
L6  
L7  
870  
655  
320  
370  
25  
340  
630  
25  
546  
162  
162  
54  
870  
800  
320  
370  
25  
340  
775  
25  
546  
162  
162  
54  
Gas side  
3-way valve  
L8  
L9  
Liquid side  
2-way valve  
L10  
L11  
74.5  
79  
74.5  
79  
L7  
L6  
L8  
L9  
18 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-C3681C(H)L, LV-D48(60)81C(H)L  
42.5  
Indoor Unit  
415  
Top View  
42.5  
1
415  
1
82.5  
C
82.5  
Bracket Hanger  
B
698  
A
Side View  
Front View  
Dim.(mm)  
Model No.  
A
B
C
LV-C3681C(H)L  
1605  
1905  
235  
270  
1440  
LV-D4881C(H)L  
LV-D6081C(H)L  
1740  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-C3681C(H)L, LV-D48(60)81C(H)L  
Outdoor Unit  
D
W
D
W
H
H
Dim.(mm)  
W
H
D
Model  
LV-C3681C(H)L  
950  
950  
370  
370  
LV-D4881C(H)L  
LV-D6081C(H)L  
950  
1227  
20 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-C(H)368KLA(B)0, LV-C368KLA1, LV-C(H)48(60)8LLA(B)0, LV-C48(60)8LLA1  
Indoor Unit  
160  
320  
320  
650  
160  
B
A
50  
50  
C
Dim.(mm)  
A
B
C
Capacity  
LV-C(H)368KLA(B)0  
LV-C368KLA1  
1350  
1255  
220  
LV-C(H)488LLA(B)0  
LV-C488LLA1  
LV-C(H)608LLA(B)0  
LV-C608LLA1  
1750  
1655  
220  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-C(H)368KLA(B)0, LV-C368KLA1  
Outdoor Unit  
4-holes for anchor bolts  
4
3
2
1
160  
550  
870  
160  
64  
360  
Number  
Name  
Descripition  
Ø6.35  
1
2
3
4
Liquid side service valve(mm)  
Gas side service valve(mm)  
Air discharge grill  
Ø15.88  
Control Cover  
22 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dimensional Drawings  
Model No.: LV-C(H)48(60)8LLA(B)0, LV-C48(60)8LLA1  
Outdoor Unit  
W
Liquid side  
3-way valve  
Gas side  
3-way valve  
L7  
L6  
L8  
L9  
Model No.  
LV-C(H)48(60)8LLA(B)0, LV-C48(60)8LLA1  
Dim.(mm)  
W
H
900  
1,160  
370  
420  
35  
D
L1  
L2  
L3  
L4  
L5  
L6  
L7  
L8  
L9  
L10  
L11  
380  
1,130  
30  
550  
175  
175  
70  
155  
83  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-B1864CL, LV-B2464CL  
Indoor Unit  
Outdoor Unit  
TRANS-  
FORMER  
THERMISTOR  
CN-TH  
BL  
R
CAPACITOR  
BR YL  
CN-TRANS  
CN-FAN  
RD  
F
H
S
YL  
COMP.  
C
OR  
OR  
RD  
BL  
BR  
C
CAPACITOR  
MAIN PCB  
ASSY.  
RY-L  
RY-M  
RY-H  
MOTOR  
GN/YL  
BK  
FAN  
MOTOR  
DOOR S/W 1  
GN/YL  
STEP  
MOTOR  
BK  
3
FUSE  
T3.15A  
4
STEP  
MOTOR  
RY-COMP  
CN-4WAY  
BL  
CN-DISP  
GN/YL  
TERMINAL  
BLOCK  
( )  
1 L  
( )  
2 N  
3
4
DISPLAY PCB  
ASSY.  
TERMINAL  
BLOCK  
3
4
TO OUTDOOR UNIT  
POWER  
INPUT  
TO INDOOR UNIT  
Notes:  
RY  
BR  
WH  
RELAY  
BL  
RD  
YL  
BLUE  
BK  
OR  
BLACK  
BROWN  
WHITE  
RED  
ORANGE  
YELLOW  
GN/YL  
GREEN/YELLOW  
Model No.: LV-B1864H(B)L, LV-B2464H(B)L  
Indoor Unit  
Outdoor Unit  
TRANS-  
FORMER  
CAPACITOR  
THERMISTOR  
BL  
R
C
CAPACITOR  
RD  
YL  
H
C
F
S
COMP.  
CN-TRANS  
CN-TH  
CN-FAN  
FAN  
MOTOR  
BR  
YL  
OR(BR)  
BK  
OR  
RD  
BL  
MAIN PCB  
ASSY.  
RY-L  
RY-M  
RY-H  
MOTOR  
GN/YL  
BK  
REVERSING  
VALVE  
DOOR S/W 1,2  
GN/YL  
GN/YL  
STEP  
MOTOR  
BK  
BK  
BK  
BR  
3
FUSE  
T3.15A  
T/B  
WH  
STEP  
MOTOR  
RY-COMP  
CN-4WAY  
BL  
RY-4WAY  
BK  
BK  
RD  
BK  
BL  
3
GN/YL  
CN-DISP  
RT-OUTFAN  
GN/YL  
TERMINAL  
BLOCK  
( )  
1 L  
( )  
2 N  
4
5
6
7
8
TERMINAL  
BLOCK  
DISPLAY PCB  
ASSY.  
3
4
5
6
7
TO OUTDOOR UNIT  
POWER  
INPUT  
TO INDOOR UNIT  
Notes:  
RY  
BR  
WH  
RELAY  
BROWN  
WHITE  
BL  
RD  
YL  
BLUE  
BK  
BLACK  
RED  
OR  
ORANGE  
YELLOW  
GN/YL  
GREEN/YELLOW  
24 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-B2860CL  
Indoor Unit  
Outdoor Unit  
TRANS-  
FORMER  
THERMISTOR  
CN-TH  
CAPACITOR  
CAPACITOR  
BL  
CAPACITOR  
YL  
OR  
BK  
CN-TRANS  
CN-FAN  
BR  
YL  
R
FAN  
MOTOR  
RD  
OR  
RD  
BL  
COMP S  
MAIN PCB  
ASSY.  
RY-L  
RY-M  
RY-H  
P. T. C  
(OPTION)  
C
MOTOR  
GN/YL  
BK  
BK  
DOOR S/W 1,2  
4
2
8
6
1
0
TB1  
POWER  
RELAY  
GN/YL  
STEP  
MOTOR  
3
FUSE  
T3.15A  
4
STEP  
MOTOR  
RY-COMP  
CN-4WAY  
GN/YL  
CN-DISP  
TERMINAL  
BLOCK  
L
N
1
2
3
TERMINAL  
BLOCK  
( )  
1 L  
( )  
2 N  
3
4
DISPLAY PCB  
ASSY.  
POWER  
INPUT  
TO INDOOR UNIT  
3854A20077S  
3854A20039L  
TO OUTDOOR UNIT  
Notes:  
RY  
BR  
WH  
RELAY  
BROWN  
WHITE  
BL  
BLUE  
BK  
OR  
BLACK  
RD  
YL  
RED  
ORANGE  
GREEN/YELLOW  
YELLOW  
GN/YL  
Model No.: LV-B2860HL  
Indoor Unit  
Outdoor Unit  
TRANS-  
FORMER  
THERMISTOR  
CAPACITOR  
CAPACITOR  
CN-TRANS  
CN-FAN  
BL  
OR  
YL  
CN-TH  
BR  
YL  
R
FAN  
MOTOR  
RD  
OR  
RD  
BL  
S
COMP  
BK  
MAIN PCB  
ASSY.  
RY-L  
RY-M  
RY-H  
C
MOTOR  
GN/YL  
P. T. C  
(OPTION)  
BK  
OR  
DOOR S/W 1  
4
2
8
6
1
0
POWER  
RELAY  
GN/YL  
Defrost PCB  
Pipe TH  
STEP  
MOTOR  
3
BR  
FUSE  
T3.15A  
N0 NC N0 NC  
4
WH  
TNS  
L1  
L2  
BK  
STEP  
MOTOR  
RY-COMP  
CN-4WAY  
BK  
BK  
BL  
L3  
L4  
RY-4WAY  
WH  
WH  
BK  
RD  
BK  
TB2  
BK  
TB1  
BL  
RY-FAN  
CN-DISP  
BK  
BK  
TERMINAL  
BLOCK  
(
)
(
)
L
N
1 L 2 N  
3
4
5
GN/YL  
TERMINAL  
BLOCK  
( )  
1 L  
( )  
2 N  
3
4
5
6
7
8
DISPLAY PCB  
ASSY.  
CRANK-CASE  
HEATER  
POWER  
INPUT  
TO INDOOR UNIT  
3854A20126B  
TO OUTDOOR UNIT  
3854A20125A  
Notes:  
RY  
BR  
WH  
RELAY  
BL  
RD  
YL  
BLUE  
BK  
BLACK  
ORANGE  
GREEN/YELLOW  
BROWN  
WHITE  
RED  
OR  
YELLOW  
GN/YL  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-C3681HL  
Indoor Unit  
Outdoor Unit  
LINE  
SWITCH BOX  
NEUTRAL  
COMP  
CONTACTOR  
ROOM  
SENSOR  
TERMINAL BLOCK 30A  
WHITE WIRE  
L1  
L2  
L3  
1
2
3
4
5
6
BLACK WIRE  
FAN  
FREEZE  
MOTOR  
GRAY WIRE  
SWING  
WHITE WIRE  
BROWN WIRE  
BROWN WIRE  
COMP  
4WV  
BLACK WIRE  
RED WIRE  
RUN CAP  
OF  
L-COMM  
POWER SUPPLY  
E L1 L2 L3  
N
BLUE WIRE  
WHITE WIRE  
GRAY WIRE  
HIGH  
1
2
3
4
5
6
BLACK WIRE  
BLUE WIRE  
RED WIRE  
MED  
LOW  
LOW  
SWEEP  
MOTOR  
CONTACTOR COIL  
WHITE WIRE  
7
8
9
RV  
REVERSING VALVE  
BLACK WIRE  
RED WIRE  
10  
FAST FUSE 10A 250V  
GRAY WIRE  
BLUE WIRE  
TERMINAL BLOCK 30A  
GROUND  
BLOWER  
MOTOR  
WHITE WIRE  
BROWN WIRE  
RUN CAP  
OUTDOOR SENSOR  
Model No.: LV-C3681CL  
Indoor Unit  
Outdoor Unit  
26 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-D4881HL  
Indoor Unit  
Outdoor Unit  
LINE  
SWITCH BOX  
NEUTRAL  
CONTACTOR  
ROOM  
SENSOR  
COMP  
TERMINAL BLOCK 30A  
WHITE WIRE  
L1  
L2  
L3  
1
2
3
4
5
6
BLACK WIRE  
FAN  
FREEZE  
SWING  
MOTOR  
GRAY WIRE  
WHITE WIRE  
BROWN WIRE  
BROWN WIRE  
COMP  
4WV  
OF  
BLACK WIRE  
RED WIRE  
RUN CAP  
POWER SUPPLY  
E L1 L2 L3  
L-COMM  
N
BLUE WIRE  
WHITE WIRE  
GRAY WIRE  
HIGH  
1
2
3
4
5
6
BLACK WIRE  
MED  
BLUE WIRE  
LOW  
LOW  
RED WIRE  
SWEEP  
MOTOR  
CONTACTOR COIL  
WHITE WIRE  
7
8
9
RV  
REVERSING VALVE  
BLACK WIRE  
RED WIRE  
10  
FAST FUSE 10A 250V  
GRAY WIRE  
BLUE WIRE  
TERMINAL BLOCK 30A  
GROUND  
GROUND  
BLOWER  
MOTOR  
BLOWER  
MOTOR  
WHITE WIRE  
BROWN WIRE  
WHITE WIRE  
BROWN WIRE  
RUN CAP  
RUN CAP  
OUTDOOR SENSOR  
Model No.: LV-D4881CL  
Indoor Unit  
Outdoor Unit  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-D6081HL  
Indoor Unit  
Outdoor Unit  
LINE  
SWITCH BOX  
NEUTRAL  
COMP  
CONTACTOR  
FAN  
MOTOR  
BLACK WIRE  
BLACK WIRE  
WHITE WIRE  
WHITE WIRE  
ROOM  
SENSOR  
TERMINAL BLOCK 30A  
WHITE WIRE  
L1  
L2  
L3  
1
2
3
4
5
6
FREEZE  
RUN CAP  
GRAY WIRE  
SWING  
BROWN WIRE  
WHITE WIRE  
BROWN WIRE  
BROWN WIRE  
COMP  
4WV  
FAN  
MOTOR  
BLACK WIRE  
RED WIRE  
OF  
L-COMM  
POWER SUPPLY  
E L1 L2 L3  
N
RUN CAP  
BLUE WIRE  
WHITE WIRE  
GRAY WIRE  
HIGH  
1
2
3
4
5
6
BLACK WIRE  
BLUE WIRE  
RED WIRE  
MED  
LOW  
LOW  
SWEEP  
MOTOR  
CONTACTOR COIL  
WHITE WIRE  
7
8
9
RV  
REVERSING VALVE  
BLACK WIRE  
RED WIRE  
10  
FAST FUSE 10A 250V  
GRAY WIRE  
BLUE WIRE  
TERMINAL BLOCK 30A  
GROUND  
GROUND  
BLOWER  
MOTOR  
BLOWER  
MOTOR  
WHITE WIRE  
BROWN WIRE  
WHITE WIRE  
BROWN WIRE  
RUN CAP  
RUN CAP  
OUTDOOR SENSOR  
Model No.: LV-D6081CL  
Indoor Unit  
Outdoor Unit  
28 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-H368KLA0  
Indoor Unit  
Outdoor Unit  
Model No.: LV-H368KLB0  
Indoor Unit  
Outdoor Unit  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-H488LLA0  
Indoor Unit  
Outdoor Unit  
Model No.: LV-H488LLB0  
Indoor Unit  
Outdoor Unit  
30 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-H608LLA(B)0  
Indoor Unit  
Outdoor Unit  
Model No.: LV-C368KLA0  
Indoor Unit  
Outdoor Unit  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-C368KLB0  
Indoor Unit  
Outdoor Unit  
Model No.: LV-C488LLA0  
Indoor Unit  
Outdoor Unit  
32 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-C488LLB0  
Indoor Unit  
Outdoor Unit  
Model No.: LV-C608LLA(B)0  
Indoor Unit  
Outdoor Unit  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-C368KLA1  
Indoor Unit  
Outdoor Unit  
Model No.: LV-C488LLA1  
Indoor Unit  
Outdoor Unit  
34 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Wiring Diagrams  
Model No.: LV-C608LLA1  
Indoor Unit  
Outdoor Unit  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-B18(24)64CL, LV-B2860CL  
INDOOR UNIT  
OUTDOOR UNIT  
LIQUID SIDE  
CAPILLARY TUBE  
INDOOR  
COIL  
OUTDOOR  
COIL  
COMPRESSOR  
GAS SIDE  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
(inch)  
Model No.  
Gas  
1/2"  
Liquid  
Rated  
Max  
Rated  
Max  
LV-B1864CL  
LV-B2464CL  
LV-B2860CL  
1/4"  
1/4"  
3/8"  
7.5  
7.5  
5
15  
20  
20  
5
5
5
8
8
8
5/8"  
5/8"  
Model No.: LV-B18(24)64H(B)L, LV-B2860HL  
INDOOR UNIT  
OUTDOOR UNIT  
LIQUID SIDE  
CAPILLARY TUBE  
CHECK VALVE  
CAPILLARY TUBE  
INDOOR  
COIL  
OUTDOOR  
COIL  
GAS SIDE  
REVERSING  
VALVE  
COMPRESSOR  
: COOLING  
: HEATING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Rated  
(inch)  
Model No.  
Gas  
Liquid  
Rated  
Max  
Max  
LV-B1864H(B)L  
LV-B2464H(B)L  
LV-B2860HL  
1/2"  
5/8"  
5/8"  
1/4"  
1/4"  
3/8"  
7.5  
7.5  
5
15  
20  
20  
5
5
5
8
8
8
36 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-C3681CL, LV-D4881CL, LV-D6081CL  
INDOOR UNIT  
OUTDOOR UNIT  
LIQUID SIDE  
CAPILLARY TUBE  
INDOOR  
COIL  
OUTDOOR  
COIL  
COMPRESSOR  
GAS SIDE  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
3/4"  
3/4"  
3/4"  
Liquid  
Rated  
Max  
Rated  
Max  
LV-C3681CL  
LV-D4881CL  
LV-D6081CL  
3/8"  
1/2"  
1/2"  
5
5
5
20  
25  
30  
5
5
5
10  
15  
20  
Model No.: LV-C3681HL, LV-D4881HL, LV-D6081HL  
INDOOR UNIT  
OUTDOOR UNIT  
LIQUID SIDE  
INDOOR  
COIL  
OUTDOOR  
COIL  
GAS SIDE  
REVERSING  
VALVE  
COMPRESSOR  
COOLING  
HEATING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
Liquid  
Rated  
Max  
Rated  
Max  
LV-C3681HL  
LV-D4881HL  
LV-D6081HL  
3/4"  
3/4"  
3/4"  
3/8"  
1/2"  
1/2"  
5
5
5
20  
25  
30  
5
5
5
10  
15  
20  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-C368KLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
Thermister  
Eva.  
Sensor  
Thermister  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
Thermister  
OUTDOOR COIL  
Thermister  
(for LV-C368KLB0 only)  
LIQUID SIDE  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
LV-C368KLA(B)0  
(inch)  
Gas  
5/8"  
Liquid  
1/4"  
Rated  
Max  
30  
Rated  
5
Max  
20  
5
Model No.: LV-H368KLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
Thermister  
Eva.  
Sensor  
Thermister  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
Thermister  
OUTDOOR COIL  
Thermister  
(for LV-H368KLB0 only)  
LIQUID SIDE  
COOLING  
HEATING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
5/8"  
Liquid  
1/4"  
Rated  
Max  
30  
Rated  
Max  
20  
LV-H368KLA(B)0  
5
5
38 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-C488LLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
H/P S/W  
L/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
LIQUID SIDE  
Thermister  
: COOLING  
(for LV-C488LLB0 only)  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
LV-C488LLA(B)0  
(inch)  
Gas  
3/4"  
Liquid  
3/8"  
Rated  
5
Max  
50  
Rated  
Max  
30  
5
Model No.: LV-H488LLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
L/P S/W  
H/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
Thermister  
(for LV-H488LLB0 only)  
LIQUID SIDE  
COOLING  
HEATING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
3/4"  
Liquid  
3/8"  
Rated  
5
Max  
50  
Rated  
5
Max  
30  
LV-H488LLA(B)0  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-C608LLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
H/P S/W  
L/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
LIQUID SIDE  
Thermister  
(for LV-C608LLB0 only)  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
LV-C608LLA(B)0  
(inch)  
Gas  
3/4"  
Liquid  
3/8"  
Rated  
5
Max  
30  
Rated  
5
Max  
20  
Model No.: LV-H608LLA(B)0  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
L/P S/W  
H/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
Thermister  
(for LV-H608LLB0 only)  
COOLING  
HEATING  
LIQUID SIDE  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
3/4"  
Liquid  
3/8"  
Rated  
5
Max  
30  
Rated  
5
Max  
20  
LV-H608LLA(B)0  
40 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Refrigerant Cycle Diagrams  
Model No.: LV-C368KLA1  
INDOOR UNIT  
OUTDOOR UNIT  
GAS SIDE  
H/P S/W  
L/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
LIQUID SIDE  
Thermister  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
5/8"  
Liquid  
1/4"  
Rated  
7.5  
Max  
30  
Rated  
Max  
20  
LV-C368KLA1  
5
Model No.: LV-C48(60)8LLA1  
INDOOR UNIT  
OUTDOOR UNIT  
Solenoid valve  
GAS SIDE  
L/P S/W  
H/P S/W  
Air  
Sensor  
INDOOR  
COIL  
Eva.  
Sensor  
Thermister  
LIQUID SIDE  
: COOLING  
Pipe size(Diameter:Ø)  
Piping length(m)  
Elevation(m)  
Model No.  
(inch)  
Gas  
Liquid  
Rated  
Max  
Rated  
Max  
LV-C488LLA1  
LV-C608LLA1  
3/4"  
3/4"  
3/8"  
3/8"  
7.5  
7.5  
50  
30  
5
5
30  
20  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Selection Procedure  
Step 1. Determine cooling load requirements at design conditions.  
Required load conditions:  
Required cooling capacity (TC)...................................25,000 Btu/h  
Sensible capacity (SHC) ............................................19,000 Btu/h  
Temperature air entering Outdoor Unit.......................95°F  
Temperature air entering Indoor Unit .........................80°F DB/67°F WB  
DB dry bulb temperature  
WB wet bulb temperature  
Step 2. Select unit based on required cooling capacity.  
Based on Total Cooling Capacity, choose suitable model from the specification table.  
The model with a nominal net capacity of 28,000 Btu/h cooling is selected.  
The system consists of a LV-B2860CL.  
Verify the unit performance at the given conditions in accordance with step #3.  
Step 3. Determine if system selected satisfies cooling requirements.  
Enter cooling capacities table on page 44 at high speed and 95°F outdoor entering air temperature with  
80°F DB/67°F WB indoor entering air temperature.  
Total cooling capacity = 28,000 Btu/h, Sensible capacity=21,600 Btu/h  
To find capacity at intermediate conditions not in the table ;  
Interpolation should be used when design conditions are between two numbers that are in the capacity  
table.  
Extra-polation is not recommended.  
If the interconnecting piping length is more than 7.5m ;  
Find the capacity(%) at that particular interconnecting piping length from the coefficient of capacity change  
graph, on page 51.  
Multiply coeffienct factor with Total Cooling Capacity & Sensible Capacity.  
Ex: At 20m interconnecting piping length, from coefficient of capacity change graph, coeffienct factor is  
0.94.  
Capacity (%) x Total Cooling Capacity 94x28000  
=
Total Cooling Capacity =  
=26,320Btu/h  
100  
100  
Capacity (%) x Sensible Capacity 94x21600  
=
Sensible Capacity =  
=20,304Btu/h  
100  
100  
42 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
10.1 Cooling Capacity  
Model No.: LV-B1864CL  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
16.8 14.6 1.62 18.6 11.0 1.67 20.0 4.9 1.70 16.0 14.6 1.79 17.7 11.1 1.84 19.0 4.9 1.88 15.1 13.9 1.91 16.6 10.5 1.97  
17.6 16.7 1.62 18.9 13.8 1.67 20.0 9.0 1.70 16.7 16.7 1.79 18.0 13.9 1.85 19.0 9.1 1.88 15.7 15.7 1.92 16.9 13.2 1.98  
18.2 18.2 1.63 19.2 16.6 1.68 20.0 12.5 1.71 17.3 17.3 1.80 18.3 16.7 1.86 19.0 12.6 1.89 16.3 16.3 1.93 17.2 15.9 1.99  
18.8 18.8 1.63 19.4 18.5 1.68 19.8 15.2 1.71 17.9 17.9 1.80 18.5 18.5 1.86 18.8 15.3 1.90 16.8 16.8 1.93 17.4 17.4 1.99  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
17.9 4.6 2.01 14.0 13.3 2.02 15.5 10.1 2.09 16.6 4.5 2.13 12.3 12.1 2.12 13.6 9.2 2.18 14.6 4.0 2.22  
17.9 8.6 2.02 14.6 14.6 2.03 15.8 12.6 2.09 16.6 8.3 2.13 12.9 12.9 2.12 13.9 11.5 2.19 14.7 7.5 2.23  
17.9 11.9 2.02 15.2 15.2 2.04 16.0 15.2 2.10 16.6 11.4 2.14 13.3 13.3 2.13 14.1 13.8 2.20 14.6 10.4 2.24  
17.7 14.5 2.03 15.7 15.7 2.04 16.2 16.2 2.11 16.5 13.9 2.15 13.8 13.8 2.13 14.2 14.2 2.20 14.5 12.6 2.24  
Model No.: LV-B1864H(B)L  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
17.8 15.4 1.62 19.6 11.6 1.67 21.1 5.1 1.70 16.9 15.4 1.79 18.7 11.7 1.84 20.1 5.2 1.88 15.9 14.7 1.91 17.6 11.1 1.97  
18.5 17.6 1.62 20.0 14.6 1.67 21.1 9.5 1.70 17.6 17.6 1.79 19.0 14.6 1.85 20.1 9.6 1.88 16.6 16.6 1.92 17.9 13.9 1.98  
19.2 19.2 1.63 20.3 17.5 1.68 21.1 13.2 1.71 18.3 18.3 1.80 19.3 17.6 1.86 20.0 13.3 1.89 17.2 17.2 1.93 18.1 16.7 1.99  
19.9 19.9 1.63 20.5 19.5 1.68 20.9 16.1 1.71 18.9 18.9 1.80 19.5 19.5 1.86 19.9 16.1 1.90 17.8 17.8 1.93 18.3 18.3 1.99  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
18.9 4.9 2.01 14.8 14.1 2.02 16.3 10.6 2.09 17.6 4.7 2.13 13.0 12.8 2.12 14.4 9.7 2.18 15.5 4.3 2.22  
18.9 9.1 2.02 15.4 15.4 2.03 16.6 13.3 2.09 17.6 8.7 2.13 13.6 13.6 2.12 14.6 12.1 2.19 15.5 7.9 2.23  
18.8 12.6 2.02 16.0 16.0 2.04 16.9 16.1 2.10 17.5 12.1 2.14 14.1 14.1 2.13 14.9 14.6 2.20 15.4 11.0 2.24  
18.7 15.3 2.03 16.5 16.5 2.04 17.1 17.1 2.11 17.4 14.7 2.15 14.5 14.5 2.13 15.0 15.0 2.20 15.3 13.3 2.24  
Model No.: LV-B2464CL  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
22.4 18.7 2.14 24.8 14.1 2.21 26.7 6.2 2.25 21.3 18.7 2.37 23.6 14.2 2.44 25.3 6.3 2.49 20.1 17.8 2.53 22.2 13.5 2.61  
23.4 21.4 2.15 25.3 17.7 2.22 26.7 11.6 2.26 22.2 21.5 2.38 24.0 17.8 2.45 25.4 11.6 2.50 20.9 20.4 2.54 22.6 16.9 2.62  
24.3 23.5 2.15 25.6 21.3 2.22 26.6 16.0 2.26 23.1 23.1 2.38 24.3 21.4 2.46 25.3 16.1 2.50 21.7 21.7 2.55 22.9 20.3 2.63  
25.1 24.7 2.16 25.9 23.7 2.23 26.4 19.5 2.27 23.8 23.8 2.39 24.6 23.8 2.46 25.1 19.6 2.51 22.4 22.4 2.56 23.2 22.6 2.64  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
23.9 6.0 2.66 18.7 17.1 2.68 20.6 12.9 2.76 22.2 5.7 2.82 16.4 15.5 2.80 18.2 11.7 2.89 19.5 5.2 2.94  
23.9 11.1 2.67 19.5 19.5 2.69 21.0 16.2 2.77 22.2 10.6 2.82 17.1 17.1 2.81 18.5 14.7 2.90 19.5 9.6 2.95  
23.8 15.3 2.68 20.2 20.2 2.70 21.3 19.5 2.78 22.1 14.7 2.83 17.8 17.8 2.82 18.8 17.7 2.91 19.5 13.3 2.96  
23.7 18.6 2.69 20.9 20.9 2.70 21.5 21.5 2.79 22.0 17.9 2.84 18.4 18.4 2.83 19.0 19.0 2.92 19.4 16.2 2.97  
Notes: 1. All capacites are net, evaporator fan motor heat is deducted.  
3. TC=Total cooling capacity(Unit:kBtu/h)  
2. DB=Dry Bulb Temperature(°F), WB=Wet Bulb Temperature(°F)  
4. SHC=Sensible heat capacity(Unit:kBtu/h)  
5. PI=Power Input(Comp.+ indoor fan motor+outdoor fan motor) (kW)  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-B2464H(B)L  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
22.4 18.7 2.33 24.8 14.1 2.41 26.7 6.2 2.45 21.3 18.7 2.58 23.6 14.2 2.66 25.3 6.3 2.71 20.1 17.8 2.76 22.2 13.5 2.85  
23.4 21.4 2.34 25.3 17.7 2.42 26.7 11.6 2.46 22.2 21.5 2.59 24.0 17.8 2.67 25.4 11.6 2.72 20.9 20.4 2.77 22.6 16.9 2.86  
24.3 23.5 2.35 25.6 21.3 2.42 26.6 16.0 2.47 23.1 23.1 2.60 24.3 21.4 2.68 25.3 16.1 2.73 21.7 21.7 2.78 22.9 20.3 2.87  
25.1 24.7 2.36 25.9 23.7 2.43 26.4 19.5 2.47 23.8 23.8 2.60 24.6 23.8 2.69 25.1 19.6 2.74 22.4 22.4 2.79 23.2 22.6 2.88  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
23.9 6.0 2.90 18.7 17.1 2.92 20.6 12.9 3.01 22.2 5.7 3.07 16.4 15.5 3.05 18.2 11.7 3.15 19.5 5.2 3.21  
23.9 11.1 2.91 19.5 19.5 2.93 21.0 16.2 3.02 22.2 10.6 3.08 17.1 17.1 3.06 18.5 14.7 3.16 19.5 9.6 3.22  
23.8 15.3 2.92 20.2 20.2 2.94 21.3 19.5 3.03 22.1 14.7 3.09 17.8 17.8 3.07 18.8 17.7 3.17 19.5 13.3 3.23  
23.7 18.6 2.93 20.9 20.9 2.95 21.5 21.5 3.04 22.0 17.9 3.10 18.4 18.4 3.08 19.0 19.0 3.18 19.4 16.2 3.24  
Model No.: LV-B2860C(H)L  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
26.2 22.6 2.49 28.9 17.1 2.57 31.1 7.6 2.62 24.9 22.7 2.75 27.5 17.2 2.84 29.6 7.6 2.89 23.4 21.6 2.95 25.9 16.4 3.04  
27.3 26.0 2.50 29.5 21.5 2.58 31.1 14.1 2.63 26.0 26.0 2.76 28.0 21.6 2.85 29.6 14.1 2.90 24.4 24.4 2.96 26.4 20.5 3.05  
28.3 28.3 2.51 29.9 25.9 2.59 31.0 19.5 2.63 26.9 26.9 2.77 28.4 26.0 2.86 29.5 19.5 2.91 25.4 25.4 2.97 26.7 24.7 3.06  
29.3 29.3 2.51 30.2 28.7 2.59 30.9 23.7 2.64 27.8 27.8 2.78 28.7 28.7 2.87 29.3 23.8 2.92 26.2 26.2 2.98 27.0 27.0 3.07  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
27.8 7.2 3.10 21.8 20.7 3.12 24.1 15.7 3.22 25.9 6.9 3.28 19.2 18.8 3.26 21.2 14.2 3.36 22.8 6.3 3.42  
27.9 13.4 3.11 22.7 22.7 3.13 24.5 19.7 3.23 25.9 12.9 3.29 20.0 20.0 3.27 21.6 17.8 3.37 22.8 11.7 3.43  
27.8 18.6 3.12 23.6 23.6 3.14 24.9 23.7 3.24 25.8 17.8 3.30 20.8 20.8 3.28 21.9 21.5 3.38 22.7 16.1 3.44  
27.6 22.6 3.13 24.4 24.4 3.15 25.1 25.1 3.24 25.7 21.7 3.30 21.4 21.4 3.29 22.1 22.1 3.39 22.6 19.7 3.46  
Model No.: LV-C3681CL  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
33.7 29.1 2.46 37.2 22.0 2.53 40.0 9.7 2.58 32.0 29.2 2.72 35.4 22.1 2.80 38.0 9.8 2.85 30.1 27.8 2.91 33.3 21.0 3.00  
35.1 33.4 2.46 37.9 27.6 2.54 40.0 18.1 2.59 33.4 33.4 2.72 36.0 27.7 2.81 38.0 18.2 2.86 31.4 31.4 2.92 33.9 26.4 3.01  
36.4 36.4 2.47 38.4 33.2 2.55 39.9 25.0 2.60 34.6 34.6 2.73 36.5 33.4 2.82 37.9 25.1 2.87 32.6 32.6 2.92 34.4 31.7 3.02  
37.6 37.6 2.48 38.8 36.9 2.56 39.7 30.5 2.60 35.8 35.8 2.74 36.9 36.9 2.83 37.7 30.6 2.88 33.7 33.7 2.93 34.7 34.7 3.03  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
35.8 9.3 3.05 28.0 26.6 3.07 31.0 20.2 3.17 33.3 8.9 3.23 24.6 24.2 3.21 27.3 18.3 3.31 29.3 8.1 3.38  
35.8 17.3 3.06 29.2 29.2 3.08 31.5 25.3 3.18 33.3 16.5 3.24 25.7 25.7 3.22 27.7 22.9 3.32 29.3 15.0 3.39  
35.7 23.9 3.07 30.3 30.3 3.09 32.0 30.4 3.19 33.2 22.9 3.25 26.7 26.7 3.23 28.1 27.6 3.33 29.2 20.8 3.40  
35.5 29.1 3.08 31.3 31.3 3.10 32.3 32.3 3.20 33.0 27.9 3.26 27.6 27.6 3.24 28.4 28.4 3.34 29.1 25.3 3.41  
Notes: 1. All capacites are net, evaporator fan motor heat is deducted.  
3. TC=Total cooling capacity(Unit:kBtu/h)  
2. DB=Dry Bulb Temperature(°F), WB=Wet Bulb Temperature(°F)  
4. SHC=Sensible heat capacity(Unit:kBtu/h)  
5. PI=Power Input(Comp.+ indoor fan motor+outdoor fan motor) (kW)  
44 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-C3681HL  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
33.7 29.1 2.71 37.2 22.0 2.80 40.0 9.7 2.85 32.0 29.2 3.00 35.4 22.1 3.09 38.0 9.8 3.15 30.1 27.8 3.21 33.3 21.0 3.31  
35.1 33.4 2.72 37.9 27.6 2.80 40.0 18.1 2.86 33.4 33.4 3.01 36.0 27.7 3.10 38.0 18.2 3.16 31.4 31.4 3.22 33.9 26.4 3.32  
36.4 36.4 2.73 38.4 33.2 2.81 39.9 25.0 2.86 34.6 34.6 3.01 36.5 33.4 3.11 37.9 25.1 3.17 32.6 32.6 3.23 34.4 31.7 3.33  
37.6 37.6 2.73 38.8 36.9 2.82 39.7 30.5 2.87 35.8 35.8 3.02 36.9 36.9 3.12 37.7 30.6 3.18 33.7 33.7 3.24 34.7 34.7 3.34  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
35.8 9.3 3.37 28.0 26.6 3.39 31.0 20.2 3.50 33.3 8.9 3.56 24.6 24.2 3.55 27.3 18.3 3.66 29.3 8.1 3.72  
35.8 17.3 3.38 29.2 29.2 3.40 31.5 25.3 3.51 33.3 16.5 3.57 25.7 25.7 3.56 27.7 22.9 3.67 29.3 15.0 3.74  
35.7 23.9 3.39 30.3 30.3 3.41 32.0 30.4 3.52 33.2 22.9 3.58 26.7 26.7 3.57 28.1 27.6 3.68 29.2 20.8 3.75  
35.5 29.1 3.40 31.3 31.3 3.42 32.3 32.3 3.53 33.0 27.9 3.59 27.6 27.6 3.58 28.4 28.4 3.69 29.1 25.3 3.76  
Model No.: LV-D4881CL  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
44.9 39.3 3.80 49.6 29.8 3.92 53.3 13.1 4.00 42.7 39.5 4.20 47.2 29.9 4.34 50.7 13.2 4.42 40.2 37.5 4.50 44.4 28.4 4.64  
46.8 45.2 3.81 50.5 37.3 3.93 53.4 24.4 4.01 44.5 44.5 4.22 48.0 37.4 4.35 50.7 24.5 4.43 41.9 41.9 4.51 45.2 35.6 4.66  
48.6 48.6 3.83 51.2 44.9 3.95 53.2 33.8 4.02 46.2 46.2 4.23 48.7 45.1 4.36 50.6 33.9 4.44 43.5 43.5 4.53 45.8 42.9 4.67  
50.2 50.2 3.84 51.8 49.9 3.96 52.9 41.1 4.03 47.7 47.7 4.24 49.2 49.2 4.38 50.3 41.3 4.46 44.9 44.9 4.54 46.3 46.3 4.68  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
47.7 12.5 4.73 37.3 36.0 4.76 41.3 27.3 4.91 44.4 12.0 5.00 32.9 32.6 4.97 36.3 24.7 5.13 39.1 10.9 5.23  
47.7 23.3 4.74 39.0 39.0 4.77 42.0 34.1 4.92 44.4 22.4 5.01 34.3 34.3 4.99 37.0 31.0 5.15 39.1 20.3 5.24  
47.6 32.2 4.76 40.4 40.4 4.79 42.6 41.1 4.94 44.3 30.9 5.03 35.6 35.6 5.00 37.5 37.3 5.16 39.0 28.0 5.26  
47.3 39.3 4.77 41.7 41.7 4.80 43.1 43.1 4.95 44.0 37.6 5.04 36.8 36.8 5.02 37.9 37.9 5.18 38.7 34.1 5.27  
Model No.: LV-D4881HL  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
44.9 39.3 4.02 49.6 29.8 4.15 53.3 13.1 4.23 42.7 39.5 4.45 47.2 29.9 4.59 "50.713.2 4.67 40.2 37.5 4.76 44.4 28.4 4.91  
46.8 45.2 4.03 50.5 37.3 4.16 53.4 24.4 4.24 44.5 44.5 4.46 48.0 37.4 4.60 50.7 24.5 4.69 41.9 41.9 4.77 45.2 35.6 4.92  
48.6 48.6 4.05 51.2 44.9 4.17 53.2 33.8 4.25 46.2 46.2 4.47 48.7 45.1 4.61 50.6 33.9 4.70 43.5 43.5 4.79 45.8 42.9 4.94  
50.2 50.2 4.06 51.8 49.9 4.19 52.9 41.1 4.26 47.7 47.7 4.49 49.2 49.2 4.63 50.3 41.3 4.71 44.9 44.9 4.80 46.3 46.3 4.95  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
125  
73  
61  
67  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
47.7 12.5 5.00 37.3 36.0 5.03 41.3 27.3 5.19 44.4 12.0 5.29 32.9 32.6 5.26 36.3 24.7 5.43 39.1 10.9 5.53  
47.7 23.3 5.02 39.0 39.0 5.05 42.0 34.1 5.21 44.4 22.4 5.30 34.3 34.3 5.28 37.0 31.0 5.44 39.1 20.3 5.54  
47.6 32.2 5.03 40.4 40.4 5.06 42.6 41.1 5.22 44.3 30.9 5.32 35.6 35.6 5.29 37.5 37.3 5.46 39.0 28.0 5.56  
47.3 39.3 5.05 41.7 41.7 5.08 43.1 43.1 5.24 44.0 37.6 5.33 36.8 36.8 5.31 37.9 37.9 5.48 38.7 34.1 5.58  
Notes: 1. All capacites are net, evaporator fan motor heat is deducted.  
3. TC=Total cooling capacity(Unit:kBtu/h)  
2. DB=Dry Bulb Temperature(°F), WB=Wet Bulb Temperature(°F)  
4. SHC=Sensible heat capacity(Unit:kBtu/h)  
5. PI=Power Input(Comp.+ indoor fan motor+outdoor fan motor) (kW)  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-D6081CL  
Outdoor DB (°F)  
85  
95  
105  
Indoor WB (°F)  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
56.1 49.8 4.58 62.0 37.7 4.73 66.7 16.6 4.81 53.3 50.0 5.06 58.9 37.9 5.22 63.4 16.7 5.32 50.2 47.5 5.42 55.5 36.0 5.59  
58.5 57.2 4.60 63.1 47.2 4.74 66.7 30.9 4.83 55.6 55.6 5.08 60.0 47.4 5.24 63.4 31.0 5.34 52.4 52.4 5.44 56.5 45.1 5.61  
60.7 60.7 4.61 64.0 56.9 4.75 66.5 42.8 4.84 57.7 57.7 5.09 60.9 57.1 5.26 63.2 42.9 5.35 54.3 54.3 5.45 57.3 54.3 5.63  
62.7 62.7 4.62 64.7 63.2 4.77 66.1 52.1 4.86 59.6 59.6 5.11 61.5 61.5 5.27 62.8 52.3 5.37 56.1 56.1 5.47 57.9 57.9 5.64  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
45.6  
48.7  
50.5  
52.2  
PI  
TC  
SHC  
34.5  
43.2  
52.0  
53.9  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
59.7 15.9  
59.7 29.5  
59.5 40.8  
59.2 49.7  
5.70 46.7  
5.71 48.7  
5.73 50.5  
5.75 52.2  
5.73 51.6  
5.75 52.5  
5.77 53.3  
5.78 53.9  
5.91  
5.93  
5.95  
5.97  
55.5 15.2 6.02 41.1 41.1 5.99  
55.5 28.3 6.04 42.9 42.9 6.01  
55.3 39.1 6.06 44.5 44.5 6.03  
55.0 47.7 6.08 45.9 45.9 6.05  
45.4 31.3  
46.2 39.2  
46.9 46.9  
47.4 47.4  
6.18  
6.20  
6.22  
6.24  
48.8 13.8 6.30  
48.9 25.7 6.31  
48.7 35.5 6.33  
48.4 43.2 6.35  
Model No.: LV-D6081HL  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
56.1 49.8 4.28 62.0 37.7 4.42 66.7 16.6 4.50 53.3 50.0 4.74 58.9 37.9 4.89 63.4 16.7 4.98 50.2 47.5 5.07 55.5 36.0 5.23  
58.5 57.2 4.30 63.1 47.2 4.43 66.7 30.9 4.51 55.6 55.6 4.75 60.0 47.4 4.90 63.4 31.0 4.99 52.4 52.4 5.08 56.5 45.1 5.25  
60.7 60.7 4.31 64.0 56.9 4.45 66.5 42.8 4.53 57.7 57.7 4.76 60.9 57.1 4.91 63.2 42.9 5.01 54.3 54.3 5.10 57.3 54.3 5.26  
62.7 62.7 4.32 64.7 63.2 4.46 66.1 52.1 4.54 59.6 59.6 4.78 61.5 61.5 4.93 62.8 52.3 5.02 56.1 56.1 5.12 57.9 57.9 5.28  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
45.6  
48.7  
50.5  
52.2  
PI  
TC  
SHC  
34.5  
43.2  
52.0  
53.9  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
59.7 15.9  
59.7 29.5  
59.5 40.8  
59.2 49.7  
5.33 46.7  
5.34 48.7  
5.36 50.5  
5.37 52.2  
5.36 51.6  
5.38 52.5  
5.39 53.3  
5.41 53.9  
5.53  
5.55  
5.56  
5.58  
55.5 15.2 5.63 41.1 41.1 5.60  
55.5 28.3 5.65 42.9 42.9 5.62  
55.3 39.1 5.67 44.5 44.5 5.64  
55.0 47.7 5.68 45.9 45.9 5.65  
45.4 31.3  
46.2 39.2  
46.9 46.9  
47.4 47.4  
5.78  
5.80  
5.82  
5.83  
48.8 13.8 5.89  
48.9 25.7 5.91  
48.7 35.5 5.92  
48.4 43.2 5.94  
Model No.: LV-C368KLA1  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
31.3 26.4 2.80 34.6 20.0 2.89 37.2 8.8 2.94 30.2 26.9 3.09 33.4 20.4 3.19 35.9 9.0 3.25 29.2 26.2 3.31 32.2 19.8 3.42  
32.7 30.3 2.81 35.2 25.0 2.89 37.2 16.4 2.95 31.5 30.9 3.10 34.0 25.5 3.20 35.9 16.7 3.26 30.4 30.1 3.32 32.8 24.9 3.43  
33.9 33.2 2.81 35.8 30.1 2.90 37.1 22.7 2.96 32.7 32.7 3.11 34.5 30.7 3.21 35.8 23.1 3.27 31.6 31.6 3.33 33.3 29.9 3.44  
35.0 35.0 2.82 36.1 33.5 2.91 36.9 27.6 2.97 33.8 33.8 3.12 34.9 34.1 3.22 35.6 28.1 3.28 32.6 32.6 3.34 33.6 33.3 3.45  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
25.5  
28.7  
29.8  
30.8  
PI  
TC  
SHC  
19.3  
24.2  
29.1  
31.7  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
34.7 8.8  
34.7 16.3  
34.6 22.5  
34.4 27.4  
3.48 27.5  
3.49 28.7  
3.50 29.8  
3.51 30.8  
3.50 30.4  
3.51 31.0  
3.52 31.4  
3.53 31.7  
3.61  
3.62  
3.63  
3.64  
32.7 8.5  
3.68 25.5 24.3 3.66  
28.2 18.4  
28.7 23.1  
29.1 27.8  
29.4 29.4  
3.77  
3.79  
3.80  
3.81  
30.3  
8.1  
3.84  
32.7 15.8 3.69 26.6 26.6 3.67  
32.6 21.9 3.70 27.6 27.6 3.68  
32.4 26.7 3.71 28.5 28.5 3.69  
30.3 15.1 3.86  
30.2 20.9 3.87  
30.0 25.5 3.88  
Notes: 1. All capacites are net, evaporator fan motor heat is deducted.  
2. DB=Dry Bulb Temperature(°F), WB=Wet Bulb Temperature(°F)  
3. TC=Total cooling capacity(Unit:kBtu/h)  
4. SHC=Sensible heat capacity(Unit:kBtu/h)  
5. PI=Power Input(Comp.+ indoor fan motor+outdoor fan motor) (kW)  
46 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-C(H)368KLA(B)0  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
33.2 27.9 3.03 36.7 21.2 3.13 39.4 9.3 3.19 32.0 28.5 3.35 35.4 21.6 3.46 38.0 9.5 3.52 30.9 27.7 3.59 34.1 21.0 3.70  
34.6 32.1 3.04 37.3 26.5 3.14 39.4 17.4 3.20 33.4 32.7 3.36 36.0 27.0 3.47 38.0 17.7 3.53 32.2 31.9 3.60 34.7 26.3 3.71  
35.9 35.2 3.05 37.9 31.9 3.15 39.3 24.0 3.21 34.6 34.6 3.37 36.5 32.5 3.48 37.9 24.5 3.54 33.4 33.4 3.61 35.2 31.7 3.73  
37.1 37.0 3.06 38.3 35.4 3.16 39.1 29.2 3.22 35.8 35.8 3.38 36.9 36.1 3.49 37.7 29.8 3.56 34.5 34.5 3.62 35.6 35.2 3.74  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
27.0  
30.4  
31.5  
32.6  
PI  
TC  
SHC  
20.4  
25.6  
30.8  
33.6  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
36.7 9.3  
36.7 17.2  
36.6 23.8  
36.4 29.0  
3.77 29.1  
3.78 30.4  
3.79 31.5  
3.81 32.6  
3.80 32.2  
3.81 32.8  
3.82 33.3  
3.83 33.6  
3.92  
3.93  
3.94  
3.95  
34.6 9.0  
3.99 27.0 25.8 3.97  
29.8 19.5  
30.4 24.4  
30.8 29.4  
31.1 31.1  
4.09  
4.11  
4.12  
4.13  
32.1  
8.6  
4.17  
34.6 16.8 4.00 28.2 28.2 3.98  
34.5 23.2 4.01 29.2 29.2 3.99  
34.3 28.2 4.02 30.2 30.2 4.00  
32.1 16.0 4.18  
32.0 22.1 4.19  
31.8 27.0 4.21  
Model No.: LV-C(H)488LLA(B)0, LV-C488LLA1  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
43.3 34.0 4.19 47.9 25.8 4.32 51.5 11.4 4.40 41.8 34.7 4.63 46.2 26.3 4.78 49.6 11.6 4.86 40.3 33.8 4.96 44.6 25.6 5.11  
45.2 39.1 4.20 48.7 32.3 4.33 51.5 21.1 4.41 43.6 39.8 4.64 47.0 32.9 4.79 49.7 21.5 4.88 42.0 38.8 4.97 45.4 32.1 5.13  
46.9 42.8 4.21 49.4 38.9 4.35 51.3 29.2 4.43 45.2 43.7 4.66 47.7 39.6 4.80 49.5 29.8 4.89 43.6 42.5 4.99 46.0 38.6 5.14  
48.4 45.1 4.23 50.0 43.2 4.36 51.0 35.6 4.44 46.7 46.0 4.67 48.2 44.0 4.82 49.2 36.3 4.91 45.1 44.8 5.00 46.5 42.9 5.16  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
32.9  
37.8  
41.2  
42.5  
PI  
TC  
SHC  
24.9  
31.2  
37.6  
41.8  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
47.9 11.3  
47.9 21.0  
47.8 29.0  
47.5 35.4  
5.21 38.0  
5.22 39.7  
5.24 41.2  
5.25 42.5  
5.24 42.0  
5.26 42.8  
5.27 43.4  
5.29 43.9  
5.40  
5.42  
5.44  
5.45  
45.2 11.0 5.50 35.2 31.4 5.48  
45.2 20.4 5.52 36.8 36.1 5.49  
45.1 28.3 5.54 38.1 38.1 5.51  
44.8 34.4 5.55 39.4 39.4 5.53  
38.9 23.8  
39.6 29.8  
40.2 35.9  
40.7 39.8  
5.65  
5.67  
5.68  
5.70  
41.9 10.5 5.76  
41.9 19.5 5.77  
41.8 27.0 5.79  
41.5 32.8 5.81  
Model No.: LV-C(H)608LLA(B)0, LV-C608LLA1  
Outdoor DB (°F)  
Indoor WB (°F)  
85  
95  
105  
61  
67  
73  
61  
67  
73  
61  
67  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
47.9 37.7 4.96 53.0 28.5 5.11 56.9 12.6 5.21 46.2 38.4 5.48 51.1 29.1 5.65 54.9 12.8 5.76 44.6 37.4 5.87 49.3 28.3 6.05  
50.0 43.3 4.97 53.9 35.7 5.13 57.0 23.4 5.22 48.2 44.1 5.50 52.0 36.4 5.67 54.9 23.8 5.78 46.5 43.0 5.88 50.2 35.5 6.07  
51.9 47.4 4.99 54.7 43.0 5.14 56.8 32.4 5.24 50.0 48.3 5.51 52.8 43.8 5.69 54.8 33.0 5.79 48.3 47.1 5.90 50.9 42.7 6.09  
53.6 49.9 5.00 55.3 47.8 5.16 56.4 39.4 5.26 51.7 50.9 5.53 53.3 48.7 5.70 54.5 40.2 5.81 49.9 49.6 5.92 51.5 47.5 6.11  
Outdoor DB (°F)  
Indoor WB (°F)  
105  
115  
67  
125  
73  
61  
73  
61  
67  
73  
Indoor DB (°F)  
TC  
SHC  
PI  
TC  
SHC  
36.4  
41.8  
45.6  
47.1  
PI  
TC  
SHC  
27.6  
34.5  
41.6  
46.2  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
TC  
SHC  
PI  
75  
80  
85  
90  
53.0 12.5  
53.0 23.2  
52.9 32.1  
52.6 39.1  
6.16 42.1  
6.18 43.9  
6.20 45.6  
6.22 47.1  
6.20 46.5  
6.22 47.4  
6.24 48.0  
6.26 48.6  
6.40  
6.42  
6.44  
6.46  
50.0 12.2 6.52 39.0 34.7 6.48  
50.0 22.6 6.54 40.7 39.9 6.50  
49.9 31.3 6.56 42.2 42.2 6.52  
49.6 38.1 6.58 43.6 43.6 6.54  
43.1 26.3  
43.9 32.9  
44.5 39.7  
45.0 44.1  
6.69  
6.71  
6.73  
6.75  
46.3 11.6 6.81  
46.3 21.6 6.83  
46.2 29.8 6.85  
45.9 36.3 6.87  
Notes: 1. All capacites are net, evaporator fan motor heat is deducted.  
2. DB=Dry Bulb Temperature(°F), WB=Wet Bulb Temperature(°F)  
3. TC=Total cooling capacity(Unit:kBtu/h)  
4. SHC=Sensible heat capacity(Unit:kBtu/h)  
5. PI=Power Input(Comp.+ indoor fan motor+outdoor fan motor) (kW)  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
10.2 Heating Capacity  
Model No.: LV-B1864H(B)L  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
TC  
42.8  
TC  
50.0  
TC  
59.0  
TC PI  
TC  
PI  
PI  
PI  
PI  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
13.5  
13.1  
12.7  
12.2  
11.8  
1.3  
1.4  
1.4  
1.5  
1.5  
15.9 1.5  
15.4 1.5  
15.0 1.6  
14.4 1.6  
13.9 1.7  
18.4  
17.8  
17.3  
16.7  
16.1  
1.6 19.3  
1.7 18.7  
1.7 18.2  
1.8 17.5  
1.8 16.9  
1.7  
1.7  
1.8  
1.8  
1.9  
20.3  
19.6  
19.0  
18.4  
17.7  
1.7 21.4  
1.8 20.7  
1.8 20.0  
1.9 19.4  
1.9 18.7  
1.7  
1.8  
1.9  
1.9  
2.0  
23.2  
22.4  
21.8  
21.0  
20.3  
1.8  
1.9  
1.9  
2.0  
2.1  
25.6 2.0  
24.8 2.0  
24.0 2.1  
23.2 2.2  
22.4 2.2  
Model No.: LV-B2464H(B)L  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
42.8  
TC  
50.0  
59.0  
TC  
PI  
TC  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
16.2  
15.7  
15.2  
14.7  
14.2  
1.9  
1.9  
2.0  
2.1  
2.1  
19.1 2.0  
18.5 2.1  
17.9 2.2  
17.3 2.3  
16.7 2.3  
22.1  
21.4  
20.8  
20.0  
19.3  
2.2 23.2  
2.3 22.5  
2.4 21.8  
2.5 21.0  
2.5 20.3  
2.3  
2.4  
2.5  
2.5  
2.6  
24.3  
23.5  
22.8  
22.0  
21.3  
2.4 25.7  
2.4 24.9  
2.5 24.0  
2.6 23.3  
2.7 22.5  
2.4  
2.5  
2.6  
2.7  
2.7  
27.8  
26.9  
26.1  
25.2  
24.3  
2.5  
2.6  
2.7  
2.8  
2.9  
30.7 2.7  
29.7 2.8  
28.8 2.9  
27.8 3.0  
26.8 3.1  
Model No.: LV-B2860HL  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
42.8  
TC  
50.0  
59.0  
TC  
PI  
TC  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
18.9  
18.3  
17.8  
17.1  
16.5  
2.1  
2.1  
2.2  
2.3  
2.4  
22.3 2.3  
21.6 2.3  
20.9 2.4  
20.2 2.5  
19.5 2.6  
25.8  
25.0  
24.2  
23.3  
22.5  
2.5 27.1  
2.6 26.2  
2.6 25.4  
2.7 24.5  
2.8 23.7  
2.5  
2.6  
2.7  
2.8  
2.9  
28.4  
27.5  
26.7  
25.7  
24.8  
2.6 30.0  
2.7 29.0  
2.8 28.0  
2.9 27.1  
3.0 26.2  
2.7  
2.8  
2.9  
2.9  
3.0  
32.5  
31.4  
30.5  
29.4  
28.4  
2.8  
2.9  
3.0  
3.1  
3.2  
35.8 3.0  
34.7 3.1  
33.7 3.2  
32.4 3.3  
31.3 3.4  
Model No.: LV-C3681HL  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
42.8  
TC  
50.0  
59.0  
TC  
PI  
TC  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
24.3  
23.6  
22.8  
22.0  
21.3  
2.1  
2.2  
2.3  
2.3  
2.4  
28.7 2.3  
27.7 2.4  
26.9 2.5  
25.9 2.5  
25.1 2.6  
33.1  
32.1  
31.1  
30.0  
29.0  
2.5 34.8  
2.6 33.7  
2.7 32.7  
2.8 31.5  
2.9 30.4  
2.6  
2.7  
2.8  
2.9  
2.9  
36.5  
35.3  
34.3  
33.0  
31.9  
2.7 38.5  
2.8 37.3  
2.9 36.0  
2.9 34.9  
3.0 33.7  
2.7  
2.8  
2.9  
3.0  
3.1  
41.7  
40.4  
39.2  
37.8  
36.5  
2.9  
3.0  
3.1  
3.2  
3.2  
46.1 3.1  
44.6 3.2  
43.3 3.3  
41.7 3.4  
40.3 3.5  
Notes : 1. All capacities are net, indoor fan motor heat is deducted.  
2. Capacities are based on the following conditions.  
Outdoor air : 85%RH. However, the condition on nominal capacity is 44.6°FDB/42.8°FWB.  
3. TC=Total heating capacity(Unit:kBtu/h)  
4. PI=Power Input(Comp.+indoor fan motor+outdoor fan motor) (kW)  
48 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-H368KLA(B)0  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
TC  
42.8  
TC  
50.0  
TC  
59.0  
TC PI  
TC  
PI  
PI  
PI  
PI  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
25.0  
24.2  
23.5  
22.6  
21.9  
2.4  
2.5  
2.6  
2.7  
2.8  
29.4 2.7  
28.5 2.8  
27.7 2.9  
26.7 2.9  
25.8 3.0  
34.1  
33.0  
32.0  
30.9  
29.8  
2.9 35.8  
3.0 34.6  
3.1 33.6  
3.2 32.4  
3.3 31.3  
3.0  
3.1  
3.2  
3.3  
3.4  
37.5  
36.3  
35.2  
34.0  
32.8  
3.1 39.6  
3.2 38.4  
3.3 37.0  
3.4 35.9  
3.5 34.6  
3.1  
3.2  
3.4  
3.5  
3.6  
42.9  
41.5  
40.3  
38.8  
37.5  
3.3  
3.4  
3.5  
3.6  
3.8  
47.3 3.5  
45.8 3.7  
44.5 3.8  
42.9 3.9  
41.4 4.0  
Model No.: LV-H488LLA(B)0  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
TC  
42.8  
TC  
50.0  
59.0  
TC  
PI  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
34.9  
33.8  
32.8  
31.6  
30.5  
3.2  
3.3  
3.4  
3.5  
3.6  
41.1 3.5  
39.8 3.6  
38.7 3.7  
37.3 3.8  
36.0 4.0  
47.6  
46.1  
44.7  
43.1  
41.6  
3.8 50.0  
3.9 48.4  
4.1 47.0  
4.2 45.3  
4.3 43.7  
3.9  
4.0  
4.2  
4.3  
4.4  
52.4  
50.7  
49.2  
47.4  
45.8  
4.0 55.4  
4.2 53.6  
4.3 51.7  
4.4 50.1  
4.6 48.4  
4.1  
4.2  
4.4  
4.5  
4.7  
59.9  
58.0  
56.3  
54.3  
52.4  
4.3  
4.5  
4.6  
4.8  
4.9  
66.1 4.6  
64.0 4.8  
62.1 4.9  
59.9 5.1  
57.8 5.2  
Model No.: LV-H608LLA(B)0  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
TC  
42.8  
TC  
50.0  
59.0  
TC  
PI  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
38.5  
37.3  
36.2  
34.9  
33.7  
3.8  
3.9  
4.0  
4.2  
4.3  
45.4 4.1  
43.9 4.3  
42.6 4.4  
41.1 4.5  
39.7 4.7  
52.5  
50.8  
49.3  
47.5  
45.9  
4.5 55.1  
4.6 53.4  
4.8 51.8  
5.0 49.9  
5.1 48.2  
4.6  
4.8  
4.9  
5.1  
5.3  
57.8  
55.9  
54.3  
52.3  
50.5  
4.8 61.0  
4.9 59.1  
5.1 57.0  
5.3 55.3  
5.4 53.4  
4.9  
5.0  
5.2  
5.3  
5.5  
66.1  
64.0  
62.1  
59.8  
57.8  
5.1  
5.3  
5.5  
5.6  
5.8  
72.9 5.5  
70.6 5.7  
68.5 5.8  
66.0 6.0  
63.8 6.2  
Notes : 1. All capacities are net, indoor fan motor heat is deducted.  
2. Capacities are based on the following conditions.  
Outdoor air : 85%RH. However, the condition on nominal capacity is 44.6°FDB/42.8°FWB.  
3. TC=Total heating capacity(Unit:kBtu/h)  
4. PI=Power Input(Comp.+indoor fan motor+outdoor fan motor) (kW)  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Performance Data  
Model No.: LV-D4881HL  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
TC  
42.8  
TC  
50.0  
TC  
59.0  
TC PI  
TC  
PI  
PI  
PI  
PI  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
32.4  
31.4  
30.5  
29.4  
28.4  
2.6  
2.7  
2.8  
2.9  
3.0  
38.2 2.9  
37.0 3.0  
35.9 3.1  
34.6 3.2  
33.4 3.3  
44.2  
42.8  
41.5  
40.0  
38.6  
3.1 46.4  
3.2 44.9  
3.3 43.6  
3.4 42.0  
3.5 40.6  
3.2  
3.3  
3.4  
3.5  
3.7  
48.6  
47.1  
45.7  
44.0  
42.5  
3.3 51.4  
3.4 49.8  
3.5 48.0  
3.7 46.5  
3.8 44.9  
3.4  
3.5  
3.6  
3.7  
3.8  
55.6  
53.9  
52.3  
50.4  
48.6  
3.6  
3.7  
3.8  
3.9  
4.0  
61.4 3.8  
59.5 3.9  
57.7 4.1  
55.6 4.2  
53.7 4.3  
Model No.: LV-D6081HL  
Outdoor WB (°F)  
35.6 39.2  
TC TC PI  
Indoor  
DB(°F)  
14.0  
23.0  
TC PI  
32.0  
42.8  
TC  
50.0  
59.0  
TC  
PI  
TC  
PI  
PI  
PI  
TC  
PI  
TC  
PI  
60.8  
64.4  
68.0  
71.6  
75.2  
40.5  
39.3  
38.1  
36.7  
35.4  
3.6  
3.8  
3.9  
4.0  
4.1  
47.8 4.0  
46.2 4.1  
44.9 4.3  
43.2 4.4  
41.8 4.5  
55.2  
53.5  
51.9  
50.0  
48.3  
4.3 58.0  
4.5 56.2  
4.6 54.5  
4.8 52.5  
4.9 50.7  
4.5  
4.6  
4.8  
4.9  
5.1  
60.8  
58.9  
57.1  
55.1  
53.2  
4.6 64.2  
4.8 62.2  
4.9 60.0  
5.1 58.2  
5.2 56.2  
4.7  
4.8  
5.0  
5.2  
5.3  
69.5  
67.3  
65.3  
63.0  
60.8  
4.9  
5.1  
5.3  
5.4  
5.6  
76.8 5.3  
74.3 5.5  
72.1 5.6  
69.5 5.8  
67.1 6.0  
Notes : 1. All capacities are net, indoor fan motor heat is deducted.  
2. Capacities are based on the following conditions.  
Outdoor air : 85%RH. However, the condition on nominal capacity is 44.6°FDB/42.8°FWB.  
3. TC=Total heating capacity(Unit:kBtu/h)  
4. PI=Power Input(Comp.+indoor fan motor+outdoor fan motor) (kW)  
Correction Factor for Heating Capacity due to Frost on Heat Exchanger and Defrosting Operation.  
The heating capacity in the "Heating Capacity" Table above indicates the actual heating capacity excluding the effect of frost on the heat  
exchanger and the defrosting operation. Therefore, use the following factor to calculate the average heating capacity including capacity  
reduction by frost on the exchanger and defrosting operation.  
Correction Factor  
Outdoor Air Temperature  
14  
21.2  
24.8  
28.4  
32  
35.6  
39.2  
42.8  
(°FWB, RH=85%)  
Correction Factor  
0.95  
0.95  
0.89  
0.87  
0.87  
0.89  
0.91  
1.00  
50 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. The Coefficient of Capacity Change  
Model No.: LV-B18(24)64C(H/B)L, LV-B2860C(H)L, LV-C3681C(H)L, LV-D4881C(H)L, LV-D6081C(H)L except VK/VL chassis  
100  
Heating  
90  
Cooling  
80  
70  
7.5  
10  
20  
30  
40  
Total Pipe Length(m)  
Model  
18k  
Additional Refrigerant  
30g/m  
30g/m  
30g/m  
50g/m  
55g/m  
60g/m  
24k  
28k  
36k  
48k  
60k  
Notes:  
Refer to the specification for the maximum pipe length of each model.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. The Coefficient of Capacity Change  
Model No.: LV-C(H)368KLA(B)0, LV-C(H)48(60)8LLA(B)0  
100  
36k Heating  
36k Cooling  
90  
48k Heating  
60k Heating  
60k Cooling  
48k Cooling  
80  
70  
5
10  
20  
30  
40  
50  
Total Pipe Length(m)  
Model  
Additional Refrigerant  
LV-C488LLA0  
LV-C488LLB0  
LV-C608LLA0  
LV-C608LLB0  
LV-H488LLA0  
LV-H488LLB0  
LV-H608LLA0  
LV-H608LLB0  
60g/m  
LV-C368KLA0  
LV-C368KLB0  
LV-H368KLA0  
LV-H368KLB0  
50g/m  
Notes:  
Refer to the specification for the maximum pipe length of each model.  
52 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. The Coefficient of Capacity Change  
Model No.: LV-C368KLA1, LV-C48(60)8LLA1  
100  
36k Heating  
36k Cooling  
90  
48k Heating  
48k Cooling  
60k Heating  
60k Cooling  
80  
70  
7.5  
10  
20  
30  
40  
50  
Total Pipe Length(m)  
Model  
Additional Refrigerant  
LV-C368KLA1  
LV-C488LLA1  
LV-C608LLA1  
50g/m  
Notes:  
Refer to the specification for the maximum pipe length of each model.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. Operation Limit  
Item  
Limit  
Inlet air temperature  
(Cooling)  
54(129.2)  
48(118.4)  
Standard operation  
Operation with the  
optional low ambient kit  
21(69.8)  
-10(14)  
Tropical model  
* Note:If the ambient temperature goes below  
5°C(41°F), the capacity drops down even  
if the low ambient kit is installed.  
15(59)  
24(75.2)  
Indoor air temperature °C W.B.(°F)  
Inlet air temperature  
(Heating)  
18(64.4)  
-10(14)*  
Standard operation  
10(50)  
24(75.2)  
Indoor air temperature °C D.B.(°F)  
* LV-C3601HL, LV-D4881HL, LV-D6081HL: 1°C(33.8°F)  
Power source voltage  
Voltage at starting  
Rating ±10%  
Min. 85% of rating  
54 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. Air Velocity and Temperature Distributions(Reference Data)  
18kBtu/h Models - Installation on ceiling  
Cooling  
Heating  
Discharge angle:45°  
Discharge angle:45°  
Air velocity [m/s]  
Air velocity [m/s]  
2.7m  
2m  
2.7m  
2m  
1.25  
1m  
1.0  
0.75  
1.0  
2m  
1m  
0m  
1m  
0m  
0.5  
0.75  
3m  
0.5  
4m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
8m  
7m  
6m  
5m  
0m  
Temperature [˚C]  
Temperature [˚C]  
2.7m  
2m  
2.7m  
2m  
33  
19  
1m  
0m  
1m  
0m  
25  
27  
23  
25  
4m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
8m  
7m  
6m  
5m  
3m  
2m  
1m  
0m  
18kBtu/h Models - Installation on the floor or wall  
Cooling Heating  
Discharge angle:45°  
Discharge angle:45°  
Air velocity [m/s]  
Air velocity [m/s]  
2.7m  
2m  
2.7m  
2m  
0.5  
0.5  
0.75  
0.75  
1.0  
1.0  
1m  
0m  
1m  
0m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
Temperature [˚C]  
Temperature [˚C]  
2.7m  
2m  
2.7m  
2m  
25  
25  
27  
23  
33  
19  
1m  
0m  
1m  
0m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
8m  
7m  
6m  
5m  
4m  
3m  
2m  
1m  
0m  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. Sound Levels  
Overall  
Notes:  
- Sound measured at 1m away from the center of the unit.  
- Data is valid at free field condition  
- Data is valid at nominal operation condition  
- Reference accoustic pressure OdB = 20µPa  
- Sound level will vary depending on a range of factors such as  
the construction(acoustic absorption coefficient) of particular  
room in which the equipment is installed.  
1m  
1m  
Microphone  
Model  
- The operating conditions are assumed to be standard.  
Sound Levels(dBA)  
Sound Levels(dBA)  
Model  
H
M
L
H
M
L
LV-B1864C(H/B)L  
LV-B2464C(H/B)L  
LV-B2860C(H)L  
43  
45  
50  
40  
37  
LV-C3681CL  
51  
48  
42  
42  
48  
39  
46  
LV-C3681HL  
51  
52  
56  
55  
58  
48  
47  
52  
50  
55  
45  
42  
46  
45  
47  
LV-D4881CL  
LV-C(H)368KLA(B)0  
LV-C368KLA1  
LV-D4881HL  
43  
41  
39  
LV-D6081CL  
LV-D6081HL  
LV-C(H)488LLA(B)0  
LV-C488LLA1  
LV-C(H)608LLA(B)0  
LV-C608LLA1  
54  
52  
50  
56  
54  
52  
Sound Levels  
LV-B1864C(H/B)L  
LV-B2464C(H/B)L  
LV-B2860C(H)L  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
NC-70  
NC-70  
NC-70  
NC-65  
NC-60  
NC-55  
NC-65  
NC-60  
NC-55  
NC-65  
NC-60  
NC-55  
NC-50  
NC-45  
NC-50  
NC-45  
NC-50  
NC-45  
NC-40  
NC-35  
NC-40  
NC-35  
NC-40  
NC-35  
NC-30  
NC-30  
NC-30  
NC-25  
NC-20  
NC-25  
NC-20  
NC-25  
NC-20  
NC-15  
NC-15  
NC-15  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
LV-C3681C(H)L  
LV-D4881C(H)L  
LV-D6081C(H)L  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
NC-70  
NC-70  
NC-70  
NC-65  
NC-60  
NC-55  
NC-65  
NC-60  
NC-55  
NC-65  
NC-60  
NC-55  
NC-50  
NC-45  
NC-50  
NC-45  
NC-50  
NC-45  
NC-40  
NC-35  
NC-40  
NC-35  
NC-40  
NC-35  
NC-30  
NC-30  
NC-30  
NC-25  
NC-20  
NC-25  
NC-20  
NC-25  
NC-20  
NC-15  
NC-15  
NC-15  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
56 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. Sound Levels  
LV-C(H)368KLA(B)0  
LV-C368KLA1  
LV-C(H)488LLA(B)0  
LV-C488LLA1  
LV-C(H)608LLA(B)0  
LV-C608LLA1  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
60  
50  
40  
30  
20  
10  
90  
80  
70  
NC-70  
NC-70  
NC-70  
NC-65  
NC-60  
NC-55  
NC-65  
NC-60  
NC-55  
NC-50  
NC-45  
NC-65  
60  
NC-60  
NC-55  
50  
NC-50  
NC-50  
NC-45  
NC-40  
NC-35  
NC-45  
40  
NC-40  
NC-40  
NC-35  
NC-35  
30  
NC-30  
NC-30  
NC-30  
NC-25  
NC-25  
NC-20  
NC-25  
NC-20  
20  
NC-20  
NC-15  
NC-15  
NC-15  
10  
63  
125  
250  
500  
1000 2000 4000 8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
Octave Band Center Frequency (Hz)  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
15.1 Selection of best location  
More than  
20cm  
1) Indoor Unit  
R
More than  
20cm  
There should not be any heat source or steam near  
the unit.  
There should not be any obstacles to the air circula-  
More than eye-level  
tion.  
(Ceiling installation)  
More than  
20cm  
There should be easy provision of condensate  
drain.  
Taking into account the noise prevention criteria,  
spot the installation.  
More than  
20cm  
R
Keep proper distance of the unit from ceiling, fence,  
walls & other obstacles as shown figure.  
The indoor unit must have the maintenance space  
around.  
(Floor/Wall installation)  
2) Outdoor Unit  
If an roof is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from  
the condenser is not restricted.  
Do not place animals and plants in the path of the warm air.  
Take the air conditioner weight into account and select a place where noise and vibration are minimum.  
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.  
Rooftop Installations : If the outdoor unit is installed on a roof structure, be sure to level the unit.  
Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes  
regarding rooftop mounting.  
Sunr  
More than  
oof  
Sunr  
oof  
30cm  
More than 50cm  
(Service space)  
More than  
30cm  
More than  
30cm  
Fence or  
obstacles  
More than  
More than  
30cm  
30cm  
Fence or  
obstacles  
More than 50cm  
More than 50cm  
More than 70cm  
More than 70cm  
15.2 Settlement of outdoor unit  
Anchor the outdoor unit with a bolt and nut(ø10mm) tightly  
and horizontally on a concrete or rigid mount.  
Tubing connection  
Bolt  
When installing on the wall, roof or rooftop, anchor the  
mounting base securely with a nail or wire assuming the  
influence of wind and earthquake.  
In the case when the vibration of the unit is conveyed to  
the hose, secure the unit with an anti-vibration rubber.  
58 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
15.3 Indoor unit installation  
VB Chassis Models  
Before Installing, prepare Installation Plates  
Side Plate  
'Installation Plates' are attached at the bottom of indoor  
unit.  
Detach them by removing each 3 screws at both sides.  
Pull the upper right and left side of 'Inlet Grille' to the  
front, and it will stop at slightly tilted position.  
Unhook the 'Inlet hanger' from the 'Hanger screw' on  
the both left and right side.  
Install Plate  
Detach the 'Inlet Grille' from the Indoor Unit.  
Detach 'Side Plate (R,L)' by removing each 3 screws  
on both sides.  
Inlet hanger  
Hanger  
screw  
Inlet Grille  
R
1) Installation on the ceiling  
265  
1076  
1)  
Measure and mark the position for the Suspension  
bolts and the piping hole.  
Drill the hole for anchor nut on the ceiling.  
Suspension  
bolt  
Before secure the Installation Plates, select the  
bent direction of the Installion Plate to the inside  
or the outside according to the installation cir-  
cumstances.  
Center-line for the  
piping hole  
1236  
265  
2)  
Drill the piping hole on the wall slightly tilted to the out-  
door side using a ø70 hole-core drill.  
WALL  
Indoor  
Outdoor  
5~7mm  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Anchor nut  
Insert the nuts and washer onto the suspension  
bolts for locking the suspension bolts on the ceiling.  
Mount the suspension bolts to the anchor-nuts firm-  
ly.  
1)  
Ceiling  
Nut  
Washer  
Suspension  
bolts  
Secure the Installation plates onto the Suspension  
bolts (adjust level roughly.) using nuts, washers and  
spring washers.  
Suspension  
bolts  
Spring  
washer  
Nut  
max.  
12mm  
Washer  
2)  
Engage 2 hooks on the both left and right side  
of the unit to the lower slot of Installation  
Plates.  
Lower slot  
Level gauge  
Adjust a level with a level gauge on the direc-  
tion of left-right, back-forth by adjusting sus-  
pension bolts.  
R
Move the hooks on the unit to the upper slot of  
Installation Plates. Then the unit will be  
declined to the bottomside so as to drain well.  
Suspension  
bolt  
Adjust a level  
Installation plate  
R
Upper slot  
R
60 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
CAUTION  
1. Install declination of the indoor unit is very important for the drain of the convertible type air  
conditioner.  
2. Minimum thickness of the insulation for the connecting pipe shall be 7mm.  
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined  
to the bottomside.  
Front of view  
The unit must be horizontal or declined to the drain hose connected when finished installation.  
Ceiling  
Drain hose  
Ceiling  
Side of view  
The unit must be declined to the bottomside of the unit when finished installation.  
Ceiling  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Secure the unit to the Installation Plates with four M8 bolts and  
washers.  
R
Before working, refer to "Flaring Work"  
on page 74  
Fit the projection hooks of the side plates to the 'Side Panel'  
R
Fasten the screws.  
R
Hook up the Inlet Grille Hook to the cabinet.  
Hang the Inlet Hanger to the screw.  
Inlet hanger  
R
Hook  
Cabinet Bottom  
62 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
2) Installation on the Wall  
Select and mark the position for fixing bolts and piping  
hole.  
1076  
more than  
260  
Decide the position for fixing bolts slightly tilted to the  
drain direction after considering the direction of drain  
hose.  
Drill the hole for anchor nut on the wall.  
265  
Drill the piping hole on the wall slightly tilted to the out-  
door side using a ø70 hole-core drill.  
Wall  
Indoor  
Outdoor  
Secure the 'Install Plate' onto the wall with four anchor  
bolts, washers and spring washers.  
Spring  
washer  
Wall  
Nut  
Washer  
Anchor nut  
Less than  
12mm  
Before secure the Install Plates, select the bent direc-  
tion of the 'Install Plate' to the inside or outside accord-  
ing to the installation circumstances.  
1236  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Install the Indoor unit onto Installation Plate.  
Insert 2 hooks on the both left and right side of the  
unit to the inner slot (wall side) of the Installation  
Plate.  
Inner slot  
Secure the unit to the Installation Plate with four M8  
bolts and washers.  
Before working, refer to "Flaring Work"  
on page 74  
Fit the projection hooks of the side plates to the 'Side  
Panel' and the 'Front Panel' by  
lifting it.  
Fasten the screws.  
Hook up the Inlet Grille Hook to the cabinet.  
Hang the Inlet Hanger to the screw.  
64 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
3) Installation on the floor  
Installation of Mount Bracket.  
From the left wall  
more than 760mm  
Select and mark the position for Mount Brackets and  
the piping hole.  
From the  
right wall  
more than 840mm  
Drill the hole for the anchor nut on the wall.  
Drill the piping hole using a ø70 hole-core drill.  
Secure the Mount Brackets on the wall with four M4  
screws.  
Install the indoor unit onto the Mount Brackets.  
Engage the slot at the back of the unit with Mount  
Bracket.  
Slot  
Floor mount  
bracket  
Drill the piping hole with 70mm dia, hole core drill.  
Piping hole should be slightly slant to the outdoor side.  
Wall  
Indoor  
Outdoor  
After Installing, reassemble detached parts.  
Hang the 'Inlet Grille' and hook the 'Inlet Hanger' to the  
Hanger Screw.  
Slot  
Assemble the 'Side Plates(R,L)' with 2 screws on both  
left and right side.  
Wall  
Floor mount  
bracket  
Install plate  
Piping hole  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
VC/VD Chassis Models  
Safety considerations  
Installation and servicing of air conditioning equipment can be hazardous due to system pressure and electrical  
components. Only trained and qualified personnel should service equipment. When working with installation  
and service of air conditioners, observe carefully the precautions written in the literature and labels attached to  
the unit along with other safety precautions that may apply. Follow all safety codes. Wear safety glasses and  
work gloves. Use quenching cloth for brazing operations. Have a fire extinguisher available for all brazing oper-  
ations.  
Warning !  
Before performing service or maintenance operations on the system, turn off the main power switches of both  
indoor and outdoor unit. Electrical shock could cause fatal injury.  
Initial check  
(1) The carton should not be removed from unit until it reaches final location, to avoid damage.  
(2) Inspect unit for shipping damage before installation.  
(3) Check field electrical work:  
(A) Proper capacity of fuses and wires should be used. Correct wiring connections and grounding should be  
done as specified by the local electrical area codes.  
(B) Check supply voltage, which must be within the limits as shown on the nameplate.  
(4) There should be easy provision of condensate drain.  
(5) Use proper size of insulation material.  
(6) Before installing select the location without any obstalcles. Also there should be provision for servicing the  
unit.  
Location & Mounting  
(1) Unit should be installed for horizontal and vertical discharge application only.  
(2) The unit comes with, two (2) bracket hangers for mounting the unit on the ceiling, or on the wall, a packet  
containing a bracket for mounting the remote control unit.  
(3) Attach the mounting bolt (1) at the distance specified in fig.1  
(4) Fasten the bracket-hanger (2&3) to the mounting bolt with washers and nuts.  
Dim (mm)  
A
B
C
Model  
36k  
1605  
1905  
235  
270  
1440  
1740  
48k, 60k  
66 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
(5) Remove unit from carton and carefully place the unit's mounting bolts into the bracket-hangers slot.  
After all the four (4) bolts are in the slots, push the unit towards bolts slowly. Secure the unit on the bracket-  
hanger by tightening all the four (4) bolts.  
Condensate drain  
(1) The unit should be at the reasonable level and pitched toward the drain, so as to ensure proper drainage.  
(2) Connect the soft hard vinyl chloride pipe to the coupling, see fig.4  
(3) Drainage is done by gravity effect, therefore the piping outside the unit should have a slope downwards.  
(4) Avoid draining as shown in fig.5  
Fig. 2  
Fig. 3  
Refrigerant piping  
(1) Indoor unit should have flared connections.  
(1.1) Make flare joints for both suction and liquid line .  
(1.2) Ensure tube and fitting are in line before tightening the nut to provide concentric seating of tube on fit-  
ting to prevent leakage.  
(2) The pipes can be bend around the rear as shown in figure 4.  
(3) Brazing should be performed with a constant purge of nitrogen through the piping. This is to keep inside of  
tubing clean.  
(4) Insulate suction and liquid line separately to prevent sweating .  
Fig. 4  
(5) Use two spanners to connect the flare nut connections. See fig.5  
Fig. 5  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
(6) Recommended combinations.  
(A) Total maximum length up to 20m.  
(B) Limit the number of bends to less than 8.  
(C) Piping fall limitation is upto 15m, see figure 6.  
(D) Piping head limitation is upto 8m, see figure 6.  
(7) Gas leakage test.  
Check all the brazed and flare connections for gas leakage.  
15m  
8m  
Fig. 6  
Electrical wiring  
(1) There should be sperate power spply dedicated only for air conditioner.  
(2) Wiring should be done in accordance to the local area codes.  
(3) Ground both indoor and outdoor unit.  
(4) Check wiring connections in accordance to the wiring diagram.  
Fig. 7  
Important  
(1) Secure the cables with in the cable clamp after connecting them to the terminal block.  
(2) Authorized electricians should be hired for cabling.  
(3) The remote controller is located inside the unit, behind the return air filter.  
Installation  
When mounting the indoor unit on the ceiling, floor or wall follow the following instructions as stated below:  
(1) Select a location that permits even air circulation throughout the room.  
GOOD LOCATION  
EVENLY COOLED  
BAD LOCATION OBLIQUE-LENE  
AREA ARE NOT WELL-COOLED  
Fig. 8  
68 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
(2) There should be Service space when the unit is mounted on the ceiling.  
300  
m m  
300  
m m  
Fig. 9  
(3) There should be Service space when the unit is mounted on the floor/wall.  
Fig. 10  
Air flow direction adjustment  
(1) To adjust the upward/downward direction of the air current, move the horizontal louver.  
Ensure thit the louver is not positioned so as to completely cut off the air flow from the unit.  
(2) To adjust the lateral direction of air currents activate the air sweep motor.  
Filter removal for cleaning  
(1) Push down the clip at the top of the front grill.  
(2) Swing down the grill and remove the filter for cleaning.  
Fig. 11  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
VK/VL Chassis Models  
Installation of Unit  
160  
320  
Unit should be installed for horizontal and vertical dis-  
charge application only.  
CASE 1  
B
A
50  
50  
POSITION OF SUSPENSION BOLT  
C
Apply a joint-canvas between the unit and duct to  
absorb unnecessary vibration.  
(Unit:mm)  
320 160  
Dimension  
A
B
C
Model  
36k  
1350  
1750  
1255  
1655  
220  
220  
650  
48k, 60k  
Suspension  
bolts  
CASE 2  
Spring  
washer  
Nut  
Install the unit leaning to a drainage hole side as a fig-  
Max.  
12mm  
Washer  
ure for easy water drainage.  
POSITION OF CONSOLE BOLT  
A place where the unit will be leveled and that can  
support the weight of the unit.  
A place where the unit can withstand its vibration.  
A place where service can be easily performed.  
Select and mark the position for fixing bolts.  
Drill the hole for set anchor on the face of ceiling.  
Old building  
New building  
1 Set anchor  
Insert the set anchor and washer onto the suspension  
bolts for locking the suspension bolts on the ceiling.  
2 Plate washer  
3 Spring washer  
4 Nut  
Mount the suspension bolts to the set anchor firmly.  
5 Suspension  
bolts  
Secure the installation plates onto the suspension  
bolts (adjust level roughly) using nuts, washers and  
spring washers.  
Local supply  
Set anchor  
Plate washer  
Spring washer  
Nut  
- M10  
- M10  
- W3/8 or M10  
: Tighten the nut and bolt to prevent unit falling  
Suspension bolt - W3/8 or M10  
70 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Preparing work for Installation  
Open side cover  
1. Remove two screws from side-cover as shown in fig.  
2. Unlock side-cover from side panel by slightly pulling  
the edge of side cover.  
2
3. Tap the side-cover with your palm on the  
backside.(Inlet grill side.)  
4. Hold the side-cover with other hand while tapping to  
prevent it to fall down.  
Edge part  
Recommendation: it is recommended to select the left  
side for drain to have common hole in the side-cover  
along with pipe and wiring.  
1
5. Remove the rubber stopple in the desired drain direc-  
tion.  
6. Knock out the pipe hole from the left side-cover with  
the help or nipper/plier.  
7. Knock hole on right side-cover only if right side is  
selected for water drain.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
1) Mounting the anchor Nut & Bolt(Ceiling Mounting)  
MOUNTING THE ANCHOR NUT AND BOLT  
Prepare 4 suspension bolts. (Each bolts length  
should be same.)  
Anchor nut  
Ceiling  
Measure and mark the position for the Suspension  
B
Nut  
bolts and the piping hole.  
Washer  
A
Suspension  
bolts  
Drill the hole for anchor nut on the ceiling.  
Suspension bolt  
Insert the nuts and washer onto the suspension  
bolts for locking the suspension bolts on the ceiling.  
Mount the suspension bolts to the anchor-nuts firm-  
ly.  
Secure the hangers onto the Suspension bolts  
(adjust level roughly.) using nuts, washers and  
spring washers.  
Adjust a level with a level gauge on the direction of  
left-right, back-forth by adjusting suspension bolts.  
Suspension  
bolts  
Spring  
washer  
Hangen  
Nut  
Adjust a level on the direction of top-bottom by  
adjusting supension bolts. Then the unit will be  
declined to the bottomside so as to drain well.  
Max.  
12mm  
Washer  
Dim.  
A
B
Hanging bolt  
(W3/8 or M10)  
Model  
48k, 60k  
36k  
1655  
1255  
320  
320  
Nut  
Flat washer for M10  
(accessory)  
(W3/8 or M10)  
Spring washer  
(M10)  
Flat washer for M10  
(accessory)  
Nut  
: Tighten the nut and bolt to prevent unit  
falling.  
(W3/8 or M10)  
DRILL A HOLE IN THE WALL.  
WALL  
Drill the piping hole with a ø70mm hole core drill.  
Drill the piping hole at either the right or the left with  
the hole slightly slanted to the outdoor side.  
Indoor  
Outdoor  
72 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
2) Indoor unit installation  
Hang the Indoor unit on suspension bolt as per following guidelines:  
1. Lift the indoor unit to sufficient height.  
2. Insert the suspended part of four suspension bolt in the four hangers provided on the side of main body one by  
one.  
3. Lower the indoor unit till the hangers rest on their respective flat washer.  
4. Adjust the level in the top down direction by adjusting the suspension bolts.  
Inclined the indoor unit as per direction provided in the fig  
: Installation Information For Declination  
1. Install declination of the indoor unit is very important for the drain of the convertible type air  
conditioner.  
2. Minimum thickness of the insulation for the connecting pipe shall be 7mm.  
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be  
declined to the bottomside.  
Front of view  
The unit must be horizontal or declined to the drain hose connected when finished installation.  
Ceiling  
10~20mm  
Drain hose  
Ceiling  
10~20mm  
Side of view  
The unit must be declined to the bottomside of the unit when finished installation.  
Ceiling  
5~10mm  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Insulate the joint and tubes completely.  
INSULATION, OTHERS  
All thermal insulation must comply with local requirement.  
THERMAL INSULATION  
Power cable  
REFRIGERANT PIPE  
Tape  
Insulate and tape both the gas piping and  
Liquid pipe  
liquid piping.  
Gas pipe  
TEST AND CHECK  
Thermal insulator  
After all workings are finished, check the working and operation.  
Air distribution ...............Is the air circulation good?  
Drain .............................Is the drainage smoothly and no sweating?  
Gas leakage .................Is the piping connection correctly?  
Wiring ...........................Is the wiring connection correctly?  
Lock-bolt .......................Is the lock-bolt of compressor loosened?  
Perform the work according to the Service Manual or Installation  
Guide.  
REFRIGERANT PIPING  
Use two spanners when connecting the refrigerant pipe to the unit.  
Make a bend with a radius as large as possible.  
Perform air purge with R-22 or vacuum drying.  
Flared connection (Union)  
Use a seemliness tube  
When piping work is finished, check all joints.  
Add refrigerant if piping is over 5m.  
Indoor  
Model  
Additional Refrigerant  
LV-C488LLA0  
LV-C488LLB0  
LV-C608LLA0  
LV-C608LLB0  
LV-H488LLA0  
LV-H488LLB0  
LV-H608LLA0  
LV-H608LLB0  
LV-C368KLA0  
LV-C368KLB0  
LV-H368KLA0  
LV-H368KLB0  
LV-C368KLA1  
LV-C488LLA1  
LV-C608LLA1  
Factory charged  
60g/m  
Flared connection  
(Service valve, Ball valve)  
50g/m  
Outdoor  
Select a location that satisfies the following conditions. Install the  
unit firmly in place.  
INSTALLATION OF OUT DOOR UNIT  
Select the following location  
A place where the air conditioner can get good  
ventilation.  
Above 30Cm  
Outdoor unit  
A place where it shall not annoy the neighbors.  
A place where the unit shall be leveled and that  
can support the weight of unit and withstand its  
vibrations.  
Above 30Cm  
Above 50Cm  
Face of wall  
Above 70Cm  
Keep a maintenance space  
74 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
3) Flaring Work  
Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following proce-  
dure.  
Cutting the pipes and the cable.  
1. Use the piping kit accessory or the pipes purchased  
Copper  
pipe  
locally.  
Slanted Uneven Rough  
90°  
2. Measure the distance between the indoor and the out-  
door unit.  
3. Cut the pipes a little longer than measured distance.  
4. Cut the cable 1.5m longer than the pipe length.  
Removing burrs  
Pipe  
1. Completely remove all burrs from the cut cross section  
of pipe/tube.  
Reamer  
2. Put the end of the copper tube/pipe in a downward  
direction as you remove burrs in order to avoid drop-  
ping burrs into the tubing.  
Point down  
Putting nut on  
Flare nut  
1. Remove flare nuts attached to indoor and outdoor unit,  
then put them on pipe/tube having completed burr  
removal.  
Copper tube  
(not possible to put them on after flaring work)  
Flaring work  
1. Firmly hold copper pipe in a die in the dimension shown in the table below.  
2. Carry out flaring work with the flaring tool.  
Handle  
Yoke  
Cone  
Bar  
Bar  
Outside diameter  
A
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
mm  
0~0.5  
0~0.5  
0~0.5  
0~1.0  
1.0~1.3  
Ø6.35  
Ø9.52  
Copper pipe  
Clamp handle  
Ø12.7  
Red arrow mark  
Ø15.88  
Ø19.05  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Check  
Smooth all round  
1. Compare the flared work with the figure by.  
Inside is shiny without scratches  
2. If a flared section is defective, cut it off and do flaring  
work again.  
= Improper flaring =  
Inclined Surface Cracked Uneven  
damaged  
thickness  
Even length  
all round  
4) Connecting of Piping - Indoor  
1. Prepare the indoor unit piping and drain hose for  
installation thought the wall.  
2. Align the center of the liquid side pipe.  
Indoor unit tubing  
Flare nut Pipes  
3. Sufficiently tight the flare nut of the liquid side pipe  
with hands.  
4. Tight the flare nut with two spanner, as shown.  
5. Align the center of gas side pipes.  
Open-end wrench (fixed)  
Flare nut  
6. Sufficiently tight the flare nut of the gas side pipe with  
hands.  
Connection pipe  
7. Tight the flare nut with two spanner as shown.  
Wrench  
Indoor unit tubing  
Outside diameter  
Torque  
.
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
kg m  
Ø6.35  
Ø9.52  
1.8  
4.2  
5.5  
6.6  
6.6  
Ø12.7  
Ø15.88  
Ø19.05  
Seal properly the joint of drain hole and drain pipe with  
adhesive tape to prevent leakage of water drops.  
8. If drain pipe need to be extended at the indoor side  
attach the drain pipe with indoor unit drain hose as  
shown in fig.  
Drain hose  
Indoor unit drain hose  
Vinyl tape (narrow)  
Wrap the insulation material around con-  
nection portion  
Adhesive  
9. Overlap the connection connecting pipe insulation  
material and the indoor pipe insulation martial. Bind  
them together with the vinyl tape. So that here may  
not be any gap.  
Plastic bands  
Insulation material  
76 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
10. If the piping and the drain hose are in common  
direction bundle the piping and the drain hose  
together by wrapping them with vinyl tape.  
Indoor unit pipe  
Wrap with vinyl tape  
Connection pipe  
Vinyl tape (wide)  
Connecting cable  
Pipe  
Vinyl tape(narrow)  
11. Rout the indoor tubing and the drain hose to the  
required piping hole.  
Wrap with vinyl tape  
Pipe  
Vinyl tape(wide)  
Drain hose  
NOTICE  
Gas side  
piping  
Common direction of drain and piping. Tape  
the tubing, drain hose and the connecting cable.  
Be sure that the drain hose is located at the low-  
est side of the bundle. Locating at the upper side  
can cause drain pan to overflow inside the unit.  
NOTICE  
Connecting  
cable  
Liquid side  
piping  
Drain hose  
If the drain hose is routed inside the room, insu-  
late the hose with an insulation material* so that  
dripping from "sweating"(condensation) will not  
damage furniture or floors.  
*Foamed polyethylene or equivalent is recom-  
mended.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
5) Connection of the pipes-Outdoor  
Align the center of the pipings and sufficiently tighten  
the flare nut by hand.  
Finally, tighten the flare nut with torque wrench until the  
wrench clicks.  
Outdoor unit  
Gas side piping  
When tightening the flare nut with torque wrench,  
ensure the direction for tightening follows the arrow on  
the wrench.  
(Bigger diameter)  
Liquid side  
piping  
(Smaller  
diameter)  
Outside diameter  
Torque  
.
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
kg m  
Ø6.35  
Ø9.52  
1.8  
4.2  
5.5  
6.6  
6.6  
Ø12.7  
Torque wrench  
Ø15.88  
Ø19.05  
78 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
6) Checking the Drainage  
1. Set the air direction louvers up-and-down to the posi-  
tion(horizontally) by hand.  
To check the drainage.  
1. Pour a glass of water on the evaporator using a ket-  
tle.  
2. Ensure the water flows through the drain hose of the  
indoor unit without any leakage and goes out the  
drain exit.  
Drain piping  
1. The drain hose should point downward for easy drain  
flow.  
Downward slope  
2. Do not make drain piping like the following.  
Accumulated  
drain water  
Do not raise  
Less than  
50mm gap  
Tip of drain hose  
dipped in water  
Air  
Water  
leakage  
Water  
leakage  
Water  
leakage  
Waving  
Ditch  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
7) Forming the Piping  
Form the piping by wrapping the connect-  
ing portion of the indoor unit with insula-  
tion material and secure it with two kinds  
of vinyl tapes.  
Seal small openings  
around pipings with a  
gum type sealer.  
If you want to connect an additional drain hose, the  
end of the drain outlet should be routed above the  
ground. Secure the drain hose appropriately.  
Taping  
Drain  
hose  
In cases where the outdoor unit is  
installed below the indoor unit perform the  
following.  
Pipings  
1. Tape the piping, drain hose and connecting cable  
from down to up.  
Connecting  
cable  
2. Secure the tapped piping along the exterior wall  
using saddle or equivalent.  
Trap is required to prevent water  
from entering into electrical parts.  
In cases where the outdoor unit is  
installed above the Indoor unit perform the  
following.  
Seal a small opening  
around the pipings  
with gum type sealer.  
1. Tape the piping and connecting cable from down to  
up.  
Trap  
2. Secure the taped piping along the exterior wall. Form  
a trap to prevent water entering the room.  
3. Fix the piping onto the wall by saddle or equivalent.  
Trap  
80 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
15.4 Wiring Connection  
VB Chassis Models  
R
1) Connecting cables to the Indoor Unit  
1) Firstly remove inlet grille then remove the 'Air  
Guide-L' by loosening two screws.  
2) Connect the wires to the terminals on the con-  
trol board individually according to the outdoor  
unit connections.  
AIR GUIDE-L  
Ensure the color of the wires of outdoor unit  
and the terminal No. are the same as those of  
indoor unit respectively  
INDOOR UNIT  
Cooling only type  
Terminals on the indoor unit 1(L) 2(N)  
3
3
4
4
GN/YL  
POWER  
INPUT  
Terminals on the outdoor unit  
Cooling & Heating type  
1
Clamp  
Terminals on the indoor unit 1(L) 2(N)  
3
4
5
6
7
8
2
POWER  
INPUT  
GN/YL  
Control  
Panel  
Terminals on the outdoor unit  
3
4
5
6
7
2) Clamping of cables  
1) Arrange two power cables on the control panel.  
2) First, fasten the steel clamp with a screw to the inner boss of control panel for securing the wires.  
3) For the cooling model, fix the other side of the clamp with a screw strongly.  
2
For the heat pump model, put the 0.75mm cable(thinner cable) on the clamp and tighten it with a plastic clamp to the  
other boss of the control panel.  
4) In Australia, the length of power supply cord from the entry of the power supply to the live pin on the power plug should  
be over 1.8m.  
CAUTION  
The power cord connected to the  
indoor unit should be complied with  
the following specifications  
(Type H05VV-F(Indoor)  
The power cable connected between  
the indoor and outdoor unit should  
be complied with the following  
specifications  
The connecting cable connected  
between the indoor and outdoor unit  
should be complied with the  
following specifications  
approved by HAR or SAA).  
(Type H07RN-F approved by HAR or SAA).  
(Type H07RN-F approved by HAR or SAA).  
NORMAL CROSS-  
SECTIONAL AREA  
2.5mm2(24K)  
NORMAL  
CROSS-  
SECTIONAL  
AREA  
NORMAL CROSS-  
SECTIONAL AREA  
2.5mm2(24K)  
2.0mm2(18K)  
2.0mm2(18K)  
0.75mm2  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
3) Connecting the cable to Outdoor Unit  
Outdoor unit  
Terminal block  
1. Remove the control cover from the unit by loosening  
a screw.  
Over 5mm  
Connect the wires to the terminals on the control  
board individually as specified.  
Holder for  
power supply  
cord  
2. Secure the cable onto the control board with the hold-  
er (clamper).  
Power supply  
cord  
3. Refix the cover control to the original position with the  
screw.  
Connecting  
cable  
4. Use a recongnized circuit breaker 20A(18k, 24k)  
between the power source and the unit. A disconnec-  
tion device to adequately disconnect all supply lines  
must be fitted.  
Cover control  
Holder for  
connecting  
cable  
VC/VD Chassis Models  
ELECTRIC WIRE SIZE  
ELECTRIC WIRE SIZE (SQMM)  
OUTDOOR  
FUSE CON-  
TROL  
INDOOR FUSE  
CONTROL  
CIRCUIT  
BREAKER  
MODEL  
ON THE  
IN PIPE  
75°C  
GROUND 60°C  
36k  
48k/60k  
10A / 250V  
10A / 250V  
0.5A / 250V  
0.5A / 250V  
30A / 3P.  
50A / 3P.  
-
-
6
6
CAUTION  
After the confirmation of the above conditions, prepare the wiring as follows:  
1) Never fail to have an individual power specially for the air conditioner. Guidence for wiring is in the  
circuit diagram which is pasted on the inside of control box cover.  
2) Provide a circuit breaker switch between power source and the unit.  
3) The screw which fasten the wiring in the casing of electrical fittings are liable to become loose  
due to vibrations, to which the unit is subjected during the course of transportation. Check them  
and make sure that they all are tightly fastened. (If they are loose, it could burn-out the wires.)  
4) Confirm specification of power source.  
5) Confirm electrical capacity is sufficient.  
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage  
marked on the name plate.  
7) Confirm the cable thickness should be proper as specified in the power sources specification.  
(Particularly note the relation between cable length and thickness.)  
8) Never fail to equip a leakage breaker where it is wet or moist.  
9) The following troubles would be caused by voltage drop-down.  
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to  
the normal function of a overload protection device.  
Proper starting power is not given to the compressor.  
10) The means for disconnection from a power supply shall be incorporated in the fixed wiring and  
have an air gap contact separation of at least 3mm in each active(phase) conductors.  
82 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
VK/VL Chassis Models  
1) Connecting cables to the Indoor Unit  
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.  
Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit  
respectively  
36K/48K/60K Btu (3Ø, 380V~415V)  
3 Phase  
3 Phase  
Heat Pump Model  
Cooling Model Only  
Terminals on the indoor unit  
1
2
3
4
4
S
R
T
N
S
R
T
N
Terminals on the outdoor unit  
1
2
3
POWER INPUT  
POWER INPUT  
: If a power plug is not used, provide a circuit break-  
er between power source and the unit as shown by.  
Main power source  
Air  
Conditioner  
Circuit Breaker  
Use a circuit breake  
or time delay fuse.  
The power cord connected to the outdoor unit  
should be complied with the following specifications  
(Rubber insulation, type H05RN-F approved by HAR  
or SAA).  
The connecting cable connected to the indoor and  
outdoor unit should be complied with the following  
specifications (Rubber insulation, type H05RN-F  
approved by HAR or SAA).  
Capacity  
Wire Size  
NORMAL  
36kBtu/h  
48kBtu/h  
60kBtu/h  
CROSS-SECTIONAL  
5 x 3.5mm2  
AREA 5 x 1.25mm2 (36k/48k/60k)  
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer  
or its service agent.  
Make sure that the screws of the terminal are not loose.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
Electrical Wiring - VK/VL Chassis  
Perform the electrical wiring work according to the  
electrical wiring connection.  
Circuit Breaker  
Switch box  
Main  
power source  
All wiring must comply with local requirements.  
Select a power source that is capable of supply-  
ing the current required by the air conditioner.  
Use a recognized circuit breaker between the  
power source and the unit. A disconnection  
device to adequately disconnect all supply lines  
must be fitted.  
Outdoor  
Indoor  
Capacity of circuit breaker  
Capacity  
36kBtu/h  
48kBtu/h  
60kBtu/h  
Ampere  
20A  
25A  
25A  
Connecting the Cables  
Indoor  
1. The control box of indoor unit is on the left side when  
seen from front side.  
Control terminal board  
2. Connect the cable to the indoor unit by connecting the  
wires to the terminals on the control board individually  
according to the outdoor unit connection (Ensure that  
the color of the wires of the outdoor unit and the termi-  
nal no. are same as the those of the indoor unit)  
The circuit diagram behind the panel is subject to  
change without notice.  
The earth wire should be longer than the common  
wires.  
When installing, refer to the circuit diagram behind  
the panel front of the indoor unit.  
Connect the wires firmly so that they may not be  
pulled out easily.  
Connect the wires according to color codes, refer-  
ring to the wiring diagram.  
84 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Installation  
2) Connecting the cable to the Outdoor  
Unit  
Outdoor unit  
Terminal block  
Cord Clamper  
1. Remove the Cover control from the unit by  
loosening a screw.  
Connect the wires to the terminals on the con-  
trol board individually as following.  
Power supply  
cord  
Over 5mm  
2. Secure the cable onto the control board with  
the holder (clamper).  
3. Refix the cover control to the original position  
with the screw.  
Cover control  
CAUTION  
After the confirmation of the above conditions, prepare the wiring as follows:  
1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guid-  
ed by the circuit diagram pasted on the inside of control box cover.  
2) Provide a circuit breaker switch between power source and the unit.  
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations  
to which the unit is subjected during the course of transportation. Check them and make sure that they are  
all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)  
4) Specification of power source  
5) Confirm that electrical capacity is sufficient.  
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the  
name plate.  
7) Confirm that the cable thickness is as specified in the power sources specification.  
(Particularly note the relation between cable length and thickness.)  
8) Never fail to equip a leakage breaker where it is wet or moist.  
9) The following troubles would be caused by voltage drop-down.  
Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal  
function of a overload protection device.  
Proper starting power is not given to the compressor.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. Function of Remote Controller  
For VC/VD Chassis Model  
ON/OFF  
Press button to set timer mode.  
TRANSMISSION SOURCE  
Used for sending control signal to  
the air conditioning unit.  
HOUR BUTTON  
Press button to increase the time  
1 hour in each step (24 hours).  
TIMER  
CLOCK  
FAN COOL HEAT  
FAN COOL  
ON  
OFF  
LCD DISPLAY  
MINUTE BUTTON  
HR.  
SWING SLEEP  
Press button to increase the time  
10 minutes in each step in timer  
mode and 1 minute in each step  
in real time clock.  
FAN BUTTON  
Press button to select low, Medium,  
High or Auto speed.  
SWING SLEEP  
TIMER  
LOW  
MED  
FAN  
HIGH  
AUTO  
ON  
OFF  
WARM BUTTON  
Press button to increase  
temperature 1°C in each step  
(Max. 30°C).  
COOL  
FAN  
HOUR  
WARM  
MIN  
MODE BUTTON  
Press button to select Cool, Fan or  
Heat mode.  
MODE  
HEAT  
T
E
M
P
COOL  
COOL BUTTON  
Press button to decrease  
temperature 1°C in each step  
(Min. 15°C).  
SWING  
SLEEP  
ON / OFF  
ON/OFF BUTTON  
Pressing this button will turn the air-  
conditioning unit on or off.  
SWING BUTTON  
Air distributor in all modes.  
SLEEP BUTTON  
Sleep mode will automatically  
adjust temperature and save  
energy when you are sleeping.  
LCD DISPLAYS  
TIMER  
MODE  
TIMER ON/OFF  
FAN COOL HEAT  
ON  
OFF  
FAN, COOL, HEAT  
CLOCK  
SIGNAL SENDING  
SET TEMP  
CLOCK  
HR.  
HOUR & MINUTE  
SWING SLEEP  
FAN SPEED  
AUTO  
SWING  
SLEEP  
LOW-MED-HI  
86 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. Function of Remote Controller  
Cooling Only Model(18k, 24k, 28k)  
1 OPERATION DISPLAY  
Signal transmitter  
Displays the operation conditions.  
Transmits the signals  
to the room air conditioner.  
2 START/STOP BUTTON  
Operation starts when this button is pressed and stops  
when the button is pressed again.  
3 OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
1
4 ON/OFF TIMER BUTTONS  
Used to set the time of starting and stopping operation.  
5 TIME SETTING BUTTONS  
Used to adjust the time.  
7
3
6 TIMER SET/CANCEL BUTTONS  
Used to set the timer when the desired time is obtained  
and to cancel the Timer operation.  
2
ON  
OFF  
7 AIR FLOW DIRECTION START/STOP BUTTON  
4
5
6
8
9
Used to stop or start louver movement and set the desired  
up/down airflow direction.  
SET  
CANCEL  
10  
11  
8 SLEEP MODE AUTO BUTTON  
Used to set Sleep Mode Auto operation.  
9 AIR CIRCULATION BUTTON  
Used to circulate the room air without cooling or heating  
(turns indoor fan on/off).  
10 ROOM TEMPERATURE CHECKING BUTTON  
Used to check the room temperature.  
11 RESET BUTTON  
Used prior to resetting time or after replacing batteries.  
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. Function of Remote Controller  
Heat Pump Model (18k, 24k, 28k)  
1 OPERATION DISPLAY  
Signal transmitter  
Displays the operation conditions.  
2 START/STOP BUTTON  
Transmits the signals  
to the room air conditioner.  
Operation starts when this button is pressed and stops  
when the button is pressed again.  
3 OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
4 ON/OFF TIMER BUTTONS  
1
Used to set the time of starting and stopping operation.  
5 TIME SETTING BUTTONS  
Used to adjust the time.  
6 TIMER SET/CANCEL BUTTONS  
7
3
Used to set the timer when the desired time is obtained  
and to cancel the Timer operation.  
2
7 AIR FLOW DIRECTION START/STOP BUTTON  
ON  
OFF  
Used to stop or start louver movement and set the  
desired up/down airflow direction.  
4
5
6
8
9
SET  
CANCEL  
8 SLEEP MODE AUTO BUTTON  
10  
11  
Used to set Sleep Mode Auto operation.  
9 AIR CIRCULATION BUTTON  
Used to circulate the room air without cooling or heating  
(turns indoor fan on/off).  
10 ROOM TEMPERATURE CHECKING BUTTON  
Used to check the room temperature.  
11 RESET BUTTON  
Used prior to resetting time or after replacing batter-  
ies.  
88 Ceiling & Floor, Ceiling Suspended (50Hz, R22)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. Function of Remote Controller  
For VK/VL Chassis Models  
The remote control transmits the signals to the system.  
START/STOP BUTTON  
Operation starts when this button is pressed  
and stops when the button is pressed again.  
1
Remote Control  
OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
2
3
(Cooling Only)  
(Heat Pump)  
Signal transmitter  
ROOM TEMPERATURE  
SETTING BUTTONS  
Used to select the room temperature.  
INDOOR FAN SPEED SELECTOR  
Used to select fan speed in four steps  
low, medium, high and CHAOS.  
4
5
6
JET COOL  
Used to start or stop the speed cooling/heating.  
(Speed cooling/heating operates super high fan speed.)  
5
6
1
3
CHAOS SWING BUTTON  
Used to stop or start louver movement and  
set the desired up/down airflow direction.  
4
ON/OFF TIMER BUTTONS  
Used to set the time of starting and stopping operation.  
7
8
10  
2
7
CANCEL  
9
TIME SETTING BUTTONS  
Used to adjust the time.  
SET  
ON  
OFF  
11  
8
12  
14  
TIMER SET/CANCEL BUTTON  
Used to set the timer when the desired time is obtained  
and to cancel the Timer operation.  
9
13  
SLEEP MODE AUTO BUTTON  
Used to set Sleep Mode Auto operation.  
10  
11  
AIR CIRCULATION BUTTON  
Used to circulate the room air without cooling or heating.  
Flip-up door  
(opened)  
ROOM TEMPERATURE CHECKING BUTTON  
Used to check the room temperature.  
12  
13  
14  
Operation Mode  
RESET BUTTON  
Initialize remote controller.  
Cooling Operation  
2nd F Button  
Used prior to using modes printed in blue at the bottom  
of buttons.  
Auto Operation  
Healthy Dehumidification Operation  
Heating Operation  
Cooling Model( ), Heat Pump Model(  
)
Ceiling & Floor, Ceiling Suspended (50Hz, R22) 89  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenoxx Electronics CD Player CD 2086 User Manual
Lexmark Printer 21Z0140 User Manual
Life Fitness Treadmill M051 00K75 0002 User Manual
Lincoln Electric Welder SVM165 A User Manual
Mackie DJ Equipment U40d User Manual
Magma Gas Grill A10 918L User Manual
Makita Paint Sprayer BVF104 User Manual
Masterbuilt Fryer 20010112 User Manual
Memorex MP3 Player MP3115 User Manual
Microsoft Tablet 7XR 00001 User Manual