Konica Minolta Marine Radio CS 2000 User Manual

SPECTRORADIOMETER  
CS-2000/CS-2000A  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety Precautions  
To ensure correct use of this instrument, read the following points carefully and adhere to  
them. After you have read this manual, keep it in a safe place where it can be referred to  
anytime a question arises.  
(Failure to adhere to the following points may result in  
Warning  
death or serious injury.)  
Do not use this instrument in places where flammable or combustible gases  
(gasoline etc.) are present.  
Doing so may cause fire.  
Always use the AC adapter and power cord supplied as a standard accessory  
or optional (AC-A3ꢀ2), and connect it to indoor AC outlet of rated voltage and  
frequency (ꢀ00 - ꢀ20 V or 200 - 240 V , 50/60Hz). Failure to follow either of  
these may result in damage to unit, fire or electric shock.  
If this instrument is not used for a long time, disconnect AC adapter from AC  
outlet. Accumulated dirt or water on prongs of AC adapter plug may cause fire  
and should be removed.  
Do not forcibly pull any part on power cord when unplugging since this may  
cause fire or electric shock. Gently disconnect by holding plug. Also, do not  
handle power cord with wet hands. Doing so may cause electric shock.  
Do not forcibly bend, twist or pull power cord. Also, do not place heavy object  
on power cord, or damage or modify one. Any of these may cause fire or  
electric shock due to damage to power cord.  
Do not disassemble or modify this instrument or AC adapter. Doing so may  
cause fire or electric shock.  
Do not spill liquid on this instrument or drop metal into this instrument. Should  
either of these happen, switch power off, unplug AC adapter immediately and  
contact the nearest KONICA MINOLTA authorized service facility.  
Should this instrument or AC adapter be damaged or smoke or odd smell be  
generated, do not keep using such instrument or AC adapter without correction.  
Doing so may cause fire. In such situations, switch power off immediately,  
unplug AC adapter and contact the nearest KONICA MINOLTA authorized  
service facility.  
Do not look at sun or intense light through finder of this instrument. This may  
lose your sight.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
(Failure to adhere to following points may result in injury or  
damage to this instrument or other property.)  
Caution  
Use this instrument near AC outlet for easy plugging or unplugging in using AC  
adapter.  
Do not place this instrument on unstable or sloping surface which may drop or  
overturn it. Dropping or overturning may injure someone around. Take care not  
to drop this instrument when carrying it.  
Do not move while looking inside finder since this would fall or injure user.  
Take special care in handling the ND filter or closeup lens included in the  
optional accessories. Breakage of the ND filter or closeup lens may injure  
someone around.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
This instrument is a high-accuracy spectroradiometer designed to measure luminance and  
chromaticity up to super-low luminance regions. Carefully read this manual before using one.  
Packaging material  
Be sure to save all packaging materials (corrugated cardboard boxes, pads and plastic  
bags) supplied with the purchase. This is delicate measurement instrument. Use packaging  
materials supplied in purchasing in case this instrument needs to be transferred for such  
purpose as maintenance in KONICA MINOLTA's factories. These packaging materials are  
useful for minimizing shock or vibration to this instrument in such situation.  
Should any of these packaging materials be lost or broken, please contact the nearest  
KONICA MINOLTA authorized service facility.  
Note on Use  
Operating Environment  
The standard AC adapter (AC-A3ꢀ2) of this instrument is designed specifically for use  
indoors. Do not use it outdoors.  
Do not disassemble this instrument for being composed of delicate electronic components.  
Use this instrument at rated voltage of ꢀ00 V - ꢀ20 V or 200 V - 240 V (50/60Hz).  
Connect AC power cord to AC outlet with rated voltage and frequency. Connected  
voltage should not be outside the range of ꢀ0% of nominal.  
This instrument is classified into a Pollution Degree 2 as instrument used in mainly in  
manufacturing plant, laboratory, warehouse or equivalents. Use this instrument in metal  
dust free and non condensing potential environment.  
This instrument is categorized into Installation Category II as equipment connected to  
commercially available power source.  
Connect PC for controlling this instrument to the outlet with protective grounding.  
Failure to follow this may result in electric shock due to short circuit.  
Take care not to enter foreign substance like water or metal in this instrument.  
Operating in such state cause serious danger.  
Do not use this instrument under direct sunlight or near heater. The internal temperature of this  
instrument to becomes much higher than ambient temperature which may break this instrument.  
Also, use this instrument in a well-ventilated place. To ensure proper heat dissipation,  
keep the ventilation holes free from obstructions.  
Avoid rapid change in ambient temperature which may form dew condensation.  
Avoid using this instrument in extremely dusty or humid place.  
Use the CS-2000 at ambient temperature between 5 and 35ºC and relative humidity  
80% or less (at 35ºC) with no condensation. Use the CS-2000A at ambient  
temperature between 5 and 30ºC and relative humidity 80% or less (at 30ºC) with no  
condensation. Operating this instrument outside specified temperature and humidity  
range may not satisfy its original performance.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
This Instrument  
Do not subject this instrument to strong impact or vibration.  
Do not forcibly pull, bend, or apply strong force to power cord for attached AC adapter  
or USB cable. This may result in snapping.  
Connect this unit to power source with minimal noise.  
Do not measure a high-luminance light source (including sunlight) beyond the  
measurement range. The failure to observe this warning could result in damage to the  
optical system.  
Should breakage or abnormality be found during operation, switch power off  
immediately and unplug. Then refer to “Error Check” on page 82.  
Should this instrument break down, do not try to disassemble and repair it by yourself.  
Please contact the nearest KONICA MINOLTA authorized service facility.  
Warm this instrument up for 20 minutes at least after switching power on when the  
object luminance is 2 cd/m2 or lower (measuring angle ꢀº).  
Objective lens, ND filter and Closeup lens (Optional Accessories)  
Make sure that surfaces of objective lens, ND filter or closeup lens are clear. Correct  
measurement may not be performed if there is dirt, dust, hand soil or part left unclean.  
Do not touch surface of objective lens, ND filter or closeup lens with hand.  
Do not change ambient temperature rapidly under high humidity. This may mist  
objective lens, ND filter or closeup lens, resulting in incorrect measurement.  
Note on Storage  
Body  
Do not store this instrument under direct sunlight or near heater. The internal  
temperature of this instrument becomes much higher than ambient temperature which  
may break this instrument.  
Store this instrument at ambient temperature between 0 and 35ºC and relative humidity  
80% or less (at 30ºC) with no condensation. Storage under high temperature and  
humidity may deteriorate performance of this instrument. For added safety, we  
recommend storage with such drying agent at room temperature.  
Take care not to form condensation. Avoid rapid change in ambient temperature when  
transferring body for storage.  
Put the body in a packaging box supplied when purchased or the storage case (CS-  
A30) in the optional accessories to store in safe place.  
Objective lens  
For storage, cover the objective lens with standard accessory lens cap.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning  
Body  
If this unit becomes dirty, wipe with dry and soft cloth. Do not use organic solvent like  
benzine or thinner and other chemical agent for cleaning. Should none of these  
methods be helpful, please contact the nearest KONICA MINOLTA authorized service  
facility.  
Objective lens  
Should it be gotten dirt or dust, wipe off with dry and soft cloth or lens cleaning paper. Do not  
use organic solvent like benzine or thinner and other chemical agent for cleaning. Should  
none of these methods be helpful, please contact the nearest KONICA MINOLTA authorized  
service facility.  
Notes on Transfer  
Use packaging material supplied when purchased to minimize vibration or shock  
generated during transfer.  
Put all material including unit and accessories in original packaging material when  
returning this instrument for service.  
Maintenance  
Periodical checkup is recommended annually to maintain measurement accuracy of  
instrument. For details on checkup, please contact the nearest KONICA MINOLTA  
authorized service facility.  
Disposal Method  
Make sure that the CS-2000/CS-2000A, its accessories and the packing materials are  
either disposed of or recycled correctly in accordance with local laws and regulations.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Contents  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Standard Accessories  
Lens Cap CS-A31  
Attached to objective lens for protecting it  
when not using this instrument.  
USB Cable (2 m) CS-A32  
Used for communication between this  
instrument and PC.  
AC Adapter AC-A312  
Supplies power from AC outlet.  
Input: ꢀ00 - ꢀ20 V or 200 - 240 V  
0.75 - 0.42 A  
50/60 Hz  
Output: ꢀ2 V  
3 A  
Data Management Software  
CS-S10w Professional  
Software to control this instrument from PC  
for various data management.  
The protect key is attached.  
Screw for focus ring lock CS-A38  
Locks the focus adjustment ring of the CS-  
2000/CS-2000A so that it does not move  
unintentionally and change the focus.  
· Do not use any screw except for the  
attached screw. Should it be lost or  
damaged, purchase a new CS-A38.  
· When storing the CS-2000/CS-2000A in the Storage Case (optional accessory),  
remove the screw.  
· When storing the CS-2000/CS-2000A in the packing box for transfer, remove the  
screw.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Optional Accessories  
Calibration Certificate  
ND Eyepiece Filter CS-A1  
Reduces glare during observation through  
the finder when a high-luminance object is  
measured. Be sure to place this filter in front  
of the finder when measuring high-  
luminance objects.  
ND Filter (1/10) CS-A33  
ND Filter (1/100) CS-A34  
Placed in front of objective lens for  
measurement of high luminance object.  
Calibration Certificate (for ND filter)  
Calibration certificates can be attached to  
the ND filters (ꢀ/ꢀ0) CS-A33 and (ꢀ/ꢀ00) CS-  
A34.  
Closeup Lens CS-A35  
Placed in front of objective lens for  
measurement of small object.  
Adapter for CCD camera CS-A36  
Placed between the finder and the body  
when a C-mount industrial camera is used.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
White Calibration Plate CS-A5 (without data)  
White Calibration Plate CS-A5 (with data)  
White Calibration Plate CS-A5 (with data  
and calibration certificate)  
Used for measurement of object colors.  
Three types (named, not-named, named  
with calibration certificate) are prepared.  
Tripod CS-A3  
Pan Head CS-A4  
Used when installing this instrument.  
Storage Case CS-A30  
Used to house the instrument and  
accessories or to carry them by hand. Never  
use this as a transport case.  
ꢀ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
Standard Accessories  
Optional Accessories  
Screw for  
Lens Cap focus ring lock CS-2000 Main Unit Calibration Certificate  
CS-A38  
ND Eyepiece Filter  
CS-A1  
ND Filter  
(1/10) CS-A33  
(1/100) CS-A34  
Calibration Certificate  
(for ND filter)  
Adapter  
for CCD camera  
CS-A36  
AC Adapter  
AC-A312  
Closeup Lens  
CS-A35  
USB Cable (2 m)  
CS-A32  
White Calibration Plate  
CS-A5 (w/o data)  
CS-A5 (w/ data)  
CS-A5 (w/ data and calibration certificate  
)
PC  
Pan Head  
CS-A4  
(on the market)  
Tripod  
CS-A3  
Data Management  
Software  
Storage Case  
CS-A30  
CS-S10w Professional  
ꢀꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Names and Functions of Parts  
Names of Each Part  
(7) Focus distance scale  
Handle  
(6) Focus  
adjustment ring  
(ꢀ) Power switch  
(2) AC adapter  
input terminal  
(5) Objective lens  
(ꢀ4) Screw holes for fixing  
(8) LCD screen  
(ꢀ0) Measurement  
button  
(3) USB connector  
(9) Key panel  
(ꢀ5) Vertically  
synchronized  
signal input  
terminal  
(ꢀ2) Diopter  
adjustment ring  
(4) Measuring  
angle selector  
Inside finder  
(ꢀ3) Aperture  
(ꢀꢀ) Finder  
ꢀ2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Functions of Each Part  
(1) Power switch  
Switches this instrument on/off. ( | ) for ON; (O) for OFF. …(p.23)  
(2) AC adapter input terminal Connects the attached AC adapter. ……………………(p.2ꢀ)  
(3) USB connector  
(4) Measuring angle selector Selects measurement angle among ꢀº, 0.2º and 0.ꢀº. ………(p.52)  
(5) Objective lens Directed to object for measurement. ………………………(p.53)  
Connects the USB cable when connecting to PC. ……(p.72)  
(6)Focus adjustment ring Adjusts focus of objective lens before measurement.…(p.53)  
(7) Focus distance scale Helps adjusting focus. ………………………………………(p.53)  
(8) LCD Screen  
(9) Key Panel  
Displays various screens like measurement and menu. … (p.ꢀ6)  
Offers several keys for operation of this instrument. …… (p.ꢀ4)  
(10)Measurement button For measurement. ……………………………………………(p.53)  
(11) Finder Used to observe object for measurement. ………… (p.ꢀ5, 53)  
(12) Diopter adjustment ring Adjusts diopter. ………………………………………… (p.ꢀ5, 53)  
(13)Aperture  
Indicates measuring area. …………………………………(p.53)  
Size of black circle will change depending on measuring angle.  
1º Aperture  
0.2º Aperture  
0.1º Aperture  
(14) Screw holes for fixing Used to fix this instrument with tripod or jig. …………… (p.20)  
(15) Vertically synchronized Connects the cable to input the vertically synchronized  
signal input terminal  
signal or the external sync measurement. ……………… (p.26)  
ꢀ3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Key Panel  
(1)  
(4)  
(7)  
(2)  
(3)  
(5)  
(6 )  
Main Functions of Each Key  
(1) MENU key  
The MENU screen appears if this key pressed when the  
measurement value screen appears. (p.ꢀ7)  
(2) DISPLAY key  
Selects whether chromaticity is displayed in absolute value (ABS) or difference  
(DIFF) if this key pressed when the measurement value screen appears. (p.4ꢀ)  
(3) COLOR MODE key Color space modes are switched in turn as follows, by pressing  
the key when the measurement value screen appears: Lvxy  
Lvu’v’ LvTΔuv XYZ Dominant wavelength/Excitation purity  
Spectral graph Lvxy. (p.39)  
(4) ESC key  
If this key is pressed when the MENU screen is displayed, the  
settings are canceled and the measurement value screen  
appears again. If pressed during numerical input or when making  
each setting, the settings are canceled. If pressed during  
continuous measurement, the measurement ends.  
(5) BACKLIGHT key  
(6) MEMORY key  
Selects backlight ON/OFF on LCD screen. (p.49)  
Measured data is stored in memory by pressing this key when the  
measurement value screen appears. (p.55)  
(7)  
keys  
Memory data, target color channels, calibration channels, etc.,  
are changed by pressing the key when the screen for display of  
various data appears. The cursor position is moved up and  
down, or the values and set items are changed, by pressing the  
key during numerical input or when making each setting.  
keys  
The cursor position moves right and left by pressing the key for  
numerical input or when making each setting.  
ENTER key  
Press the key to fix the contents selected in  
.
ꢀ4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Diopter Adjustment  
Rotate the diopter adjustment ring for adjustment  
of diopter.  
Diopter  
adjustment ring  
Adjust so that A or B on aperture or black circle  
indicating measuring area looks clear when  
observing object through finder.  
A
B
Adjustment would be easy starting with ꢀº  
aperture where object near aperture looks blur.  
Make sure to adjust diopter before  
measurement. Diopter should be adjusted for  
the eyesight of the person who will be taking  
measurement. If diopter is not adjusted before  
focus measurement, correct measurement value  
may not be expected. This is because the focus  
is actually off even if you think it is correctly in  
focus. In addition, if diopter is not correctly  
adjusted, you may see the aperture moving  
depending on viewing angle.  
* You sometimes see small black dots or stripes  
in internal finder. It gives no effect on  
measuring performance.  
ꢀ5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LCD Screen  
MEAS (Measurement value) screen  
“SNGLis displayed for the  
values obtained during single  
measurement, while “CONT”  
is displayed for the values  
obtained during continuous  
measurement. (p.53)  
Calibration channel (p.47) Target color channel  
(p.6ꢀ, 65, 67)  
Measurement result is displayed in the  
currently selected color space.  
(Lvxy, Lvu’v’, LvTΔuv, XYZ, Dominant  
wavelength/Excitation purity, Spectral  
graph) (p.39)  
cd  
m
2
Lv  
x
80. 00  
0 . 0000  
Display format can be changed. (p.37)  
y
Ob  
0 . 0000  
s
SPD SYNC LEN ND BL  
10˚ M-N Non C U 100 on  
Setting status in this instrument is  
displayed.  
<SPD>  
<SYNC>  
<Obs>  
Currently selected  
measuring time is  
displayed.  
“Int” is displayed when  
the internal sync  
Currently selected  
observer angle is  
displayed.  
measurement mode is  
(Nrm, Fst, M-N, M-F,  
Mnl) (p.29)  
set. “Ext” is displayed  
when the external sync  
measurement mode.  
“Non” is displayed when  
the sync measurement  
mode is not set. (p.26)  
(2°,ꢀ0°) (p.35)  
ꢀ6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MENU screen  
The MENU screen appears if MENU key is pressed when the measurement value screen  
is displayed.  
MEAS  
Used to set measurement time or  
synchronizing method. (p.26, 29)  
MEMORY  
Used to read or delete the measurement  
memory data. (p.56, 58)  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
TARGET  
Used to register, select or delete the  
target color. (p.6ꢀ, 65, 67)  
OPTION  
Used to set the closeup lens, ND filter or  
calibration channel. (p.43, 45, 47)  
SETUP  
Used to set the observer, backlight or  
display format. (p.35, 49, 37)  
<LENS>  
<ND>  
<BL>  
“C-U” is displayed, if the  
closeup lens is attached.  
If not, “Std” is displayed  
(p.43).  
The current ND filter type  
is displayed.  
“On” is displayed, if the  
backlight is set to be  
turned on during the  
measurement. “Off” is  
displayed, if the backlight  
is set to be turned off  
during that time. (p.49)  
(Non, ꢀ0, ꢀ00) (p.45)  
ꢀ7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ꢀ8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
ꢀ9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing  
Use screw holes for fixing at the bottom of this instrument if utilized with the tripod or jig.  
2-type holes are available.  
Tripod screw hole: To set on the tripod. Use a tripod screw with top diameter of 3/8 inches  
and depth of ꢀ0.5 mm.  
[Note] The tripod screw holes correspond with the 3/8-inch screws of a  
large camera tripod. ꢀ/4-inch screws cannot be used for fixing  
this instrument.  
ISO screw hole: To set on the jig. Use ISO screws with top diameter of 5 mm and depth  
of 6.5 mm.  
Measurement distance  
reference  
ISO screw Tripod screw  
ISO screw  
Optical  
axis  
70  
170  
190.4  
For other detailed dimensions, see p.80.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting AC Adapter  
The AC adapter supplied with this instrument is used for the corresponding power  
source.  
(Failure to adhere to the following points may result in death or serious injury.)  
Warning  
Always use the AC adapter and power cord supplied as a standard accessory or  
optional accessory (AC-A312), and connect it to indoor AC outlet of rated voltage  
and frequency (100 - 120 V or 200 - 240 V , 50/60Hz). Failure to follow either of  
these may result in damage to unit, fire or electric shock.  
If this instrument is not used for a long time, disconnect AC adapter from AC  
outlet. Accumulated dirt or water on prongs of AC adapter plug may cause fire and  
should be removed before use.  
Do not forcibly pull any part on power cord when unplugging since this may cause  
fire or electric shock. Gently disconnect by holding plug. Also, do not handle  
power cord with wet hands. Doing so may cause electric shock.  
Do not forcibly bend, twist or pull power cord. Also, do not place heavy object on  
power cord, or damage or modify one. Any of these may cause fire or electric  
shock due to damage to power cord.  
Do not disassemble or modify this instrument or AC adapter. Doing so may cause  
fire or electric shock.  
Should this instrument or AC adapter be damaged or smoke or odd smell be  
generated, do not keep using such instrument or AC adapter without correction.  
Doing so may cause fire. In such situations, switch power off immediately, unplug  
AC adapter and contact the nearest KONICA MINOLTA authorized service facility.  
Caution  
(Failure to adhere to following points may result in injury or damage to this instrument or other property.)  
Use this instrument near AC outlet for easy plugging or unplugging in using AC  
adapter.  
2ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connection Method  
1.  
Make sure that power switch is OFF  
(slided to [O] side).  
2.  
Connect the AC adapter plug to the  
AC adapter input terminal of the body.  
3.  
Plug the AC adapter to outlet (100 - 120 VAC  
50 Hz/60 Hz).  
or 200 - 240 VAC  
,
Insert the AC adapter plug all the way seated in AC outlet.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Switch ON( | )/OFF(O)  
The warm-up time needed is a minimum of 20 minutes in order to measure the objects  
with excellent accuracy under the conditions described below. Warm up this instrument for  
20 or more minutes when the power source is turned off even for a short period, and  
turned on again.  
(ꢀ) The object is a low-luminance light source, using 2856 K (standard light source A) as a  
guide:  
2 cd/m2 or lower (ꢀ° Aperture)  
50 cd/m2 or lower (0.2° Aperture)  
200 cd/m2 or lower (0.ꢀ° Aperture)  
(2)Outside room temperature and normal humidity ranges  
Turning power switch ON  
1.  
Slide power switch to ON ( | )  
side.  
The measurement screen appears 5  
seconds after the initial screen on the  
LCD.  
The model type (CS-2000 or CS-  
2000A), body version and product  
serial numbers are displayed on the  
initial screen. The model type can be  
also confirmed on the nameplate.  
Turning power switch OFF  
2.  
Slide power switch to OFF (O  
side) after measurement.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting of Synchronization  
The synchronized measurement refers to measurement mode where measurement is  
made in the same timing as periodical light source pulse frequency, such as vertically  
synchronized frequency for the display device.  
[INT SYNC]  
The internal sync measurement mode is used to measure the display equipment without  
the input of vertically synchronized signals to the body, or to measure flicker light from a  
light source such as a fluorescent light. Input the frequency of vertically synchronized  
signals for the display equipment, or the commercial frequency (50 or 60 Hz) for flicker  
light from a light source such as a luminescent light. The optimal integration time is  
automatically set based on the input value and the brightness of the object. For this  
reason, enter the correct frequency value to two places of decimals.  
However, if the vertically synchronized frequency of the display equipment is not clear, accurate  
measurement will not be possible with an inaccurate frequency setting. In this case it is  
recommended to select [NO SYNC] mode without sync measurement (at 60 Hz of frequency), but to  
select [MULTI-NORMAL] mode or [MULTI-FAST] mode for the measurement time (refer to p. 29).  
[EXT SYNC]  
The external sync measurement mode is used to measure the display equipment after the  
line input of a vertically synchronized signal through the input terminal for vertically  
synchronized signals to the body. The optimal integration time is set automatically, based  
on the frequency of vertically synchronized signals and the brightness of the object.Input  
CMOS (5V) Level of the input signals.  
* Range of synchronized frequencies : 20.00 to 200.00 Hz  
* Factory default setting : NO SYNC  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1.  
Press  
MENU  
key when the MEAS  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
screen is displayed.  
The MENU screen appears.  
When the backlight of the LCD has been turned  
BACKLIGHT  
off via  
key on the MEAS screen,  
y
Ob  
the backlight is turned on.  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.  
3.  
Press either  
[MEAS] and then press  
The MENU – MEAS screen appears.  
or  
key to select  
key.  
MEAS  
NORMAL  
NO SYNC  
ENTER  
SPEED  
SYNC  
The current set contents are displayed in the  
SYNC item.  
Press either  
[SYNC] and then press  
or  
key to select  
key.  
MEAS  
SYNC MODE  
ENTER  
NO SYNC  
The MENU - MEAS - SYNC MODE (sync  
method selection) screen appears.  
INT SYNC  
EXT SYNC  
4. Press either  
or  
key to select the  
MEAS  
SYNC MODE  
sync method.  
NO SYNC  
INT SYNC  
EXT SYNC  
4-a-1. INT SYNC setting:  
MEAS  
SYNC MODE  
INT SYNC  
Select [INT SYNC] and press  
key.  
ENTER  
060. 00 Hz  
The MENU - MEAS - SYNC MODE – INT  
SYNC screen appears. This screen is used  
for the input of an internal synchronized  
frequency.  
4-a-2. Press either  
value.  
or  
key to set a  
key for larger number.  
key for smaller number.  
The range of the internal synchronized  
frequency is from 20 Hz to 200 Hz.  
4-a-3. Press either  
or  
key to move  
MEAS  
SYNC MODE  
INT SYNC  
the cursor.  
050. 00 Hz  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-a-4. Repeat the same procedures 4-a-  
2. and -3. as necessary.  
4-a-5. Press  
key.  
ENTER  
After the setting is entered, the MENU -  
MEAS - SYNC MODE screen appears  
again on the LCD.  
5. Press  
key.  
ENTER  
When the synchronizing method is set, the  
MENU - MEAS screen appears again on the  
LCD.  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - MEAS screen appears  
again on the LCD.  
The setting of the synchronizing method is  
saved even after the power switch is turned off  
(O).  
6. Press  
key.  
ENTER  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
2
The MEAS screen appears again on the LCD.  
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
I n t S t dNon on  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting Measurement Time  
Select measurement time according to the purpose. Five modes are available for  
measurement time.  
Measurement  
time mode  
Examples of  
measurement subjects  
When measuring low luminances, Constant light  
Operation explanation  
Feature  
Cautions  
In this mode, integration time*ꢀ is adjusted Improved accuracy  
between 0.005s and ꢀ20s according to the and repeatability for  
brightness of the measurement subject.  
This mode emphasizes performance  
when measuring low luminances.  
since the total measurement  
time can be as long as 4  
sources (halogen  
lamps, etc.)  
luminances below  
approx. 4 cd/m2  
minutes, if the brightness of the  
(measurement angle: ꢀ°) measurement subject changes,  
the measurement results will  
be the average luminance.  
Periodic light  
sources (whose are  
stable and whose  
synchronization  
frequency is  
In addition, be careful to not  
move the instrument during  
NORMAL  
measurement. When measuring  
periodic light sources, MULTI  
INTEG-NORMAL mode or  
known)  
MULTI INTEG-FAST mode may  
be more suitable, for example,  
when the synchronization  
frequency is unknown.  
In this mode, integration time is adjusted  
between 0.005s and ꢀ6s according to the times for luminances  
brightness of the measurement subject.  
This mode emphasizes measurement  
time when measuring low luminances.  
Shorter measuring  
When higher accuracy and  
repeatability are required  
at low luminances, the  
Same as above  
Periodic light  
below approx. 4 cd/m2  
(measurement angle: ꢀ°) NORMAL mode should  
be used if necessary.  
FAST  
In this mode, several cycles of the  
integration time for NORMAL mode are  
taken and averaged. Under luminance  
conditions which require an integration  
time longer than the set luminance, the  
integration time will be the same as for  
normal measurement.  
This mode can be used when the  
synchronization time for measurement is  
unknown or when the synchronization  
time is known but the frequency is  
unstable. In such case, the sync mode  
should be set to NO SYNC.  
Measurements which do Even for high luminances,  
not depend on the  
synchronization  
frequency of the  
measurement subject  
can be taken.  
the set integration time (ꢀs or sources (whose  
longer) will be used.  
synchronization  
frequency is  
unknown or  
unstable)  
MULTI  
INTEG-  
NORMAL  
Improved accuracy and  
repeatability for  
luminances below  
approx. 4 cd/m2  
(measurement angle: ꢀ°)  
In this mode, several cycles of the  
Measurements which do Even for high luminances,  
Periodic light  
integration time for FAST mode are taken not depend on the  
the set integration time (ꢀs or sources (whose  
and averaged. Under luminance  
conditions which require an integration  
time longer than the set luminance, the  
integration time will be the same as for  
FAST measurement.  
This mode can be used when the  
synchronization time for measurement is  
unknown or when the synchronization  
time is known but the frequency is  
unstable. In such case, the sync mode  
should be set to NO SYNC.  
synchronization  
frequency of the  
longer) will be used  
synchronization  
frequency is  
unknown or  
unstable)  
measurement subject  
can be taken.  
Shorter measuring times  
for luminances below  
approx. 4 cd/m2  
MULTI  
INTEG-  
FAST  
(measurement angle: ꢀ°)  
This mode can be used when you want to set a  
fixed integration time for measurements.  
Integration time: 0.005s to ꢀ20s  
The desired fixed integration Be careful that the “OVER” error  
All light sources  
MANUAL  
time can be set.  
message does not occur and that the  
measurement accuracy is not reduced.  
*ꢀ Time for sensor to measure light indicating “exposure time”. On the other hand, measurement time shows time for  
integration × 2 +Time to open/close shutter + Time for calculation), indicating time needed for actual measurement.  
* Factory default setting : MULTI INTEG-NORMAL, IN-ND : AUTO  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
key when the MEAS  
screen is displayed.  
MENU  
cd  
m
2
Lv  
x
35. 85  
0 . 3964  
0 . 4059  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
key.  
MEAS  
NORMAL  
NO SYNC  
[MEAS] and then press  
SPEED  
SYNC  
ENTER  
The MENU – MEAS screen appears.  
The current set contents are displayed in the  
SPEED item.  
3. Press either  
or  
key to select  
key.  
MEAS  
SPEED MODE  
[SPEED] and then press  
ENTER  
NORMAL  
The MENU - MEAS - SPEED MODE  
(measurement speed setting) screen  
appears.  
FAST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Press either  
or  
key to select  
MEAS  
SPEED MODE  
measurement speed.  
NORMAL  
FAST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
4-a-1. NORMAL or FAST setting: Select  
[NORMAL] or [FAST] and press  
MEAS  
SPEED MODE  
IN ND  
AUTO  
OFF  
ON  
key.  
ENTER  
The MENU - MEAS - SPEED MODE - IN-  
ND screen appears.  
This screen is used to determine whether the  
ND filter built into the body is used or not.  
4-a-2. Press either  
or  
key to select  
MEAS  
SPEED MODE  
IN ND  
[AUTO], [OFF] or [ON].  
AUTO  
OFF  
ON  
Select [ON] when the error message “OVER” appears.  
When measuring objects having a wide range of luminance  
under the adjusted measurement conditions (ex. γ  
measurement), set IN-ND to [OFF] or [ON]. For [OFF] or [ON]  
selection, select [OFF] when the upper limit luminance is ꢀ00cd/  
m2 or less, and [ON] when it is ꢀ00cd/m2 or more as a guide.  
4-a-3. Press  
key.  
ENTER  
MEAS  
SPEED MODE  
After the setting is entered, the MENU  
- MEAS - SPEED MODE screen  
appears again on the LCD.  
NORMAL  
FA ST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
4-b-1. MULTI-NORMAL or MULTI-FAST  
setting:  
MEAS  
SPEED MODE  
MULTI INTEG  
INTEG TIME  
01  
Select [MULTI-NORMAL] or [MULTI-  
FAST] and press  
key.  
ENTER  
IN-ND AUTO  
The MENU - MEAS - SPEED MODE -  
MULTI INTEG screen appears.  
This screen is used for input of the integration  
time in the MULTI INTEG-NORMAL mode or  
MULTI INTEG-FAST mode.  
3ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-b-2. Press either  
value.  
or  
key to set a  
MEAS  
SPEED MODE  
MULTI INTEG  
INTEG TIME  
10  
key for larger number.  
key for smaller number.  
IN-ND AUTO  
The setting range of integration time is from ꢀ to ꢀ6 s.  
4-b-3. Press  
key.  
ENTER  
MEAS  
SPEED MODE  
MULTI INTEG  
The cursor moves to the IN-ND item.  
This screen is used to determine whether  
the ND filter built into the body is used or  
not.  
INTEG TIME  
10  
IN-ND AUTO  
4-b-4. Press either  
or  
key to  
MEAS  
SPEED MODE  
MULTI INTEG  
select [AUTO], [OFF] or [ON].  
INTEG TIME  
10  
Select [ON] when the error message “OVER” appears.  
When measuring objects having a wide range of luminance  
under the adjusted measurement conditions (ex. γ  
IN-ND ON  
measurement), set IN-ND to [OFF] or [ON]. For [OFF] or [ON]  
selection, select [OFF] when the upper limit luminance is ꢀ00cd/  
m2 or less, and [ON] when it is ꢀ00cd/m2 or more as a guide.  
MEAS  
SPEED MODE  
4-b-5. Press  
key.  
ENTER  
NORMAL  
After the setting is entered, the MENU -  
MEAS - SPEED MODE screen appears  
again on the LCD.  
FAST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
4-c-1. MANUAL setting:  
MEAS  
SPEED MODE  
Select [MANUAL] and press  
NORMAL  
key.  
ENTER  
FAST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
The MENU - MEAS – SPEED MODE -  
MANUAL screen appears. This screen is  
used for input of the integration time in the  
manual mode.  
MEAS  
SPEED MODE  
MANUAL  
INTEG TIME  
000033.333  
ms  
IN ND OFF  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-c-2. Press either  
value.  
or  
key to set a  
MEAS  
SPEED MODE  
MANUAL  
INTEG TIME  
key for larger number.  
000033.330  
m
s
key for smaller number.  
IN ND OFF  
The setting range of integration time is from  
5 to ꢀ20,000 ms.  
4-c-3. Press either  
the cursor.  
or  
key to move  
4-c-4. Repeat the same procedures 4-a-  
2. and -3. as necessary.  
MEAS  
SPEED MODE  
MANUAL  
INTEG TIME  
000500.000  
m
s
s
s
IN ND OFF  
4-c-5. Press  
key.  
ENTER  
MEAS  
SPEED MODE  
MANUAL  
The cursor moves to the IN-ND item.  
This screen is used to determine whether  
the ND filter built into the body is used or  
not.  
INTEG TIME  
000500.000  
m
IN ND OFF  
4-c-6. Press either  
[ON] or [OFF].  
or  
key to select  
MEAS  
SPEED MODE  
MANUAL  
INTEG TIME  
Select [ON] when the error message  
“OVER” appears.  
000500.000  
IN  
m
N
D ON  
4-c-7. Press  
key.  
ENTER  
MEAS  
SPEED MODE  
When the setting is entered, the MENU -  
MEAS - SPEED MODE screen appears  
again on the LCD.  
NORMAL  
FAST  
MULTI-NORMAL  
MULTI-FAST  
MANUAL  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Press  
key.  
ENTER  
When the measurement time is set, the MENU -  
MEAS screen appears again on the LCD.  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - MEAS screen appears  
again on the LCD.  
Measurement time setting is saved even after  
switching OFF (O).  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
2
The MEAS screen appears again on the LCD.  
Lv  
x
35. 85  
0 . 3964  
0 . 4059  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ Mn  
l
Non S t dNon on  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Observer  
Color matching function for chromaticity calculation is selectable between 2°OBS and  
ꢀ0°OBS.  
* Observer setting  
: 2°OBS, ꢀ0°OBS  
* Factory default setting : 2°OBS  
Operation Procedure  
8, 9  
1
2, 3, 4,  
5, 6, 7  
1. Press  
key when the MEAS  
screen is displayed.  
MENU  
cd  
m
2
Lv  
x
35. 85  
The MENU screen appears.  
0 . 3964  
When the backlight of the LCD has been turned  
BACKLIGHT  
the backlight is turned on.  
off via  
key on the MEAS screen,  
y
Ob  
0 . 4059  
Non S t dNon on  
s
SPD SYNC LEN ND BL  
l
2
˚ Mn  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
SETUP  
[SETUP] and then press  
key.  
ENTER  
OBSERVER  
BACKLIGHT  
2
°
@
MEAS  
O
The MENU – SETUP screen appears.  
The current set contents are displayed in  
N
F
DATA FORM  
the [OBSERVER] item.  
3. Press either  
or  
key to select  
SETUP  
OBSERVER  
[OBSERVER] and then press  
key.  
ENTER  
°
2
O
BS  
°
10  
O
BS  
The MENU - SETUP – OBSERVER (Observer  
selection) screen appears.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Press either  
or  
key to select [2º  
SETUP  
OBSERVER  
OBS] or [10º OBS].  
°
2
O
BS  
°
10  
O
BS  
5. Press  
key.  
ENTER  
SETUP  
OBSERVER  
The confirmation screen appears. [CANCEL] is  
CHANGE  
selected.  
OK  
CANCEL  
6. Press  
key to move the cursor to  
SETUP  
OBSERVER  
[OK].  
CHANGE  
OK  
CANCEL  
7
. Press  
key.  
ENTER  
When the observer angle is set, the MENU -  
MEAS screen appears again on the LCD.  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - SETUP screen appears  
again on the LCD.  
Observer setting is saved even after switching  
OFF (O).  
8. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
9. Press  
key.  
ESC  
cd  
m
2
Lv  
x
35. 85  
The MEAS screen appears again on the LCD.  
When observer angle is set to ꢀ0°, Lv display  
changes to Y display.  
0 . 3964  
y
Ob  
0 . 4059  
Non S t dNon on  
s
SPD SYNC LEN ND BL  
l
10˚ Mn  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting Display Format  
The formats of indicating the luminance and excitation values X, Y and Z can be selected as either  
normal indication to display the values to four places of decimals, or as index number indication. If  
the measurement values on the LCD are unreadable, use the index number indication.  
* Display format setting : Normal, Index  
* Factory default setting : ****.**** [F]  
* When the number of displayed digits is six (luminance and X/Y/Z are ꢀ00000 or more) in  
the normal indication, “******.*****” will be displayed. In this case, the value will be  
displayed if you set to the index number indication.  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
key when the MEAS  
screen is displayed.  
MENU  
cd  
m
2
Lv  
x
35. 85  
0 . 3964  
0 . 4059  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
the backlight is turned on.  
s
SPD SYNC LEN ND BL  
2
˚ Mn  
l
Non S t dNon on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
key.  
SETUP  
[SETUP] and then press  
ENTER  
OBSERVER  
BACKLIGHT  
2
°
@
MEAS  
O
The MENU – SETUP screen appears.  
The current set contents are displayed in the  
N
F
DATA FORM  
[DATA FORM] item.  
3. Press either  
or  
key to select  
SETUP  
DATA FORM  
[DATA FORM] and then press  
.
**** ****  
key.  
ENTER  
E
.
+
* ****  
*
The MENU - SETUP - DATA FORM (Display  
format selection) screen appears.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Press either  
or  
key to select  
SETUP  
DATA FORM  
[****.**** [F]] or [*.****E+* [E]].  
.
**** ****  
E
.
+
* ****  
*
5. Press  
key.  
ENTER  
SETUP  
OBSERVER  
BACKLIGHT  
2
°
When the display format is set, the MENU -  
@
MEAS  
O
SETUP screen appears again on the LCD.  
By pressing  
N
E
ESC  
key, after the setting is  
DATA FORM  
canceled the MENU - SETUP screen appears  
again on the LCD.  
Display format setting is saved even after  
switching OFF (O).  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
2
Lv 3. 5846E+1  
The MEAS screen appears again on the LCD.  
m
0. 3964  
x
y
Ob  
0. 4059  
Non S t dNon on  
s
SPD SYNC LEN ND BL  
l
2
˚ Mn  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting Color Space  
See below table for available color space.  
* Factory default setting :Lvxy  
LCD Screen  
Color Space  
Display Description  
(When Normal is selected for display format)
 
(When Index is selected for display format)  
Lvxy *1  
Displays and outputs in  
luminance Lv and  
chromaticity coordinates  
x,y.  
cd  
m
cd  
2
2
m
Lv  
x
34. 22  
0 . 3958  
0 . 4060  
Lv 3. 4221E+1  
0 . 3958  
x
y
Ob  
y
Ob  
0 . 4060  
Non S t dNon on  
s
SPD SYNC LEN ND BL  
s
SPD SYNC LEN ND BL  
m
2
˚ N  
r
m
Non S t dNon on  
2
˚ N  
r
Lvu’v’ *1  
Lv T ∆uv  
XYZ  
Displays and outputs in  
luminance Lv and u’v’  
chromaticity diagram  
(CIE ꢀ976 UCS  
chromaticity diagram)  
coordinates u’, v’.  
cd  
m
cd  
2
2
Lv  
u’  
v’  
34. 22  
0 . 2236  
0 . 5161  
Lv 3. 4221E+1  
m
u’  
v’  
0 . 2236  
0 . 5161  
Non S t dNon on  
Ob  
s
SPD SYNC LEN ND BL  
Ob  
s
SPD SYNC LEN ND BL  
m
2˚ N  
r
m
Non S t dNon on  
2˚ N  
r
Displays and outputs in  
luminance Lv, correlated  
color temperature T and  
color difference from  
blackbody locus uv.  
cd  
m
cd  
2
2
Lv  
T
34. 22  
3829K  
Lv 3. 4221E+1  
m
T
3829K  
duv  
duv  
Obs SPD SYNC LEN ND BL  
+0. 009  
Non S t dNon on  
+0. 009  
Non S t dNon on  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
m
r
2˚ N  
r
m
Displays and outputs in  
tristimulus values X, Y,  
Z.  
X
Y
33. 36  
34. 22  
16. 71  
X
Y
3. 3365E+1  
3. 4221E+1  
Z
Ob  
Z
Ob  
1. 6709E+1  
s
SPD SYNC LEN ND BL  
s
SPD SYNC LEN ND BL  
m
2
˚ N  
r
m
Non S t dNon on  
2
˚ N  
r
Non S t dNon on  
Dominant  
wavelength/  
Excitation purity  
*2  
Displays and outputs in  
dominant wavelength λd  
and excitation purity Pe.  
+576 . 220n  
m
d
λ
0 . 407%  
Pe  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
Spectral graph  
Displays or outputs  
spectral radiance Le(λ)  
in the spectral waveform  
380n  
1. 3118E  
m
380  
Ob  
780  
5
SPD SYNC LEN ND BL  
s
˚ N  
2
r
m
Non S t dNon on  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
*ꢀ Y is displayed instead of Lv when observer angle is ꢀ0°.  
*2 For non-spectral colors, the complementary wavelength will be displayed. The display  
indication will remain λd.  
*
If the calculated value does not establish a proper combination with the value in the  
color space mode, “_ _ _ _ _ _ _ _” will be displayed.  
Operation Procedure  
1
2
1. When the MENU or MEMORY screen  
cd  
m
2
Lv  
x
34. 22  
0 . 3958  
0 . 4060  
is displayed, press  
key to  
ESC  
switch to the MEAS screen.  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
2.  
Press  
key to display  
COLOR MODE  
cd  
m
2
Lv  
u’  
v’  
34. 22  
0 . 2236  
0 . 5161  
the desired color space.  
Measurement screen switches in order of Lvxy  
Lvu’v’ LvTuv XYZ λd/Pe Spectral  
graph Lvxy while  
COLOR MODE  
key is  
Ob  
s
SPD SYNC LEN ND BL  
pressed.  
2˚ N  
r
m
Non S t dNon on  
It switches in order of Yxy Yu’v’ XYZ λd/  
Pe Spectral graph Yxy when observer  
angle is ꢀ0°.  
Color space setting is saved even after  
switching OFF (O).  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting Absolute Value (ABS)/Difference (DIFF) Display  
Whether chromaticity value is shown in absolute (ABS) or difference (DIFF) is selectable.  
See below table for each case.  
* Factory default setting: Absolute value (ABS)  
Color Space  
Lvxy *1  
Absolute value (ABS)  
Difference (DIFF)  
Lv, x , y  
Lv, x, y  
Lv, %LV, ∆x, ∆y  
cd  
2
Lv  
x
34. 22  
0 . 3958  
0 . 4060  
m
cd  
2
2
Lv  
x
34  
3958  
4059  
.
34  
m
0
0
.
.
y
cd  
m
Lv  
+
0
.
.
1188  
35  
0000  
0001  
%
Lv  
100  
%
x
y
.
.
0
0
.
.
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
Obs  
2˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
Lvu’v’ *1  
Lv T ∆uv  
XYZ  
Lv, u’, v’  
Lv, u’, v’  
%Lv, ∆Lv, ∆u’, ∆v’  
cd  
m
2
Lv  
u’  
v’  
34. 22  
0 . 2236  
0 . 5161  
cd  
2
2
Lv  
u’  
v’  
34  
2236  
5160  
.
34  
m
0
0
.
.
cd  
m
Lv  
Lv  
+
0
.
1188  
35  
0000  
0000  
%
100  
.
%
u ’  
v ’  
+
0
.
.
0
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
r
m
Non S t dNon on  
Lv, T, duv  
Lv  
Lv, T, duv  
∆Lv, %Lv, ∆T  
cd  
m
2
34. 22  
3829K  
cd  
m
2
2
Lv  
T
duv  
34 . 34  
3830K  
+
T
0
.
009  
cd  
m
Lv  
+
100  
0
.
.
35  
OK  
1188  
%
%
Lv  
duv  
+0. 009  
Non S t dNon on  
T
Ob SPD SYNC LEN ND BL  
r
s
˚ N  
2
m
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
X, Y, Z  
X, Y, Z  
∆X, ∆Y, ∆Z  
%X, %Y, %Z  
X
Y
33. 36  
34. 22  
16. 71  
X
Y
Z
33  
34  
16  
.
.
.
.
.
.
49  
34  
78  
1204  
1188  
07479  
%
%
%
X
Y
Z
+
+
+
0
0
0
.
.
.
Z
Ob  
s
˚ N  
SPD SYNC LEN ND BL  
2
r
m
Non S t dNon on  
X%  
Y%  
Z%  
100  
100  
100  
36  
35  
45  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
λ d, Pe  
λd Pe  
∆λd, Pe *2  
Dominant wavelength  
+576 . 220n  
m
d
λ
λ
d
+
576  
0
.
406  
220n  
m
Fe  
.
0 . 407%  
Pe  
λd  
Pe  
0 . 000n  
0 . 000%  
m
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
r
m
Non S t dNon on  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
4ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Color Space  
Absolute value (ABS)  
Difference (DIFF)  
Spectral graph  
Le (λ) spectral waveform  
Measurement value and Le (λ)  
Wavelength at the cursor position spectral waveform of target color  
and Le (λ) in the wavelength  
Wavelength of the cursor position  
and Le (λ) of the measurement value  
in the wavelength  
380n  
1. 3118E  
SPD SYNC LEN ND BL  
˚ N Non S t dNon on  
m
380  
780  
5
Ob  
2
s
rm  
380n  
1.8704E  
SPD SYNC LEN ND BL  
˚ N Non S t dNon on  
m
380  
780  
+
7
Ob  
2
s
rm  
*ꢀ Y is displayed instead of Lv when observer angle is ꢀ0°.  
*2 Even if either the measured value, target color, or both are the complementary  
wavelength, the difference between the two values will be displayed. The display  
indication will remain λd.  
*
If the calculated value or the registered target color does not establish a proper  
combination with the value in the color space mode, “_ _ _ _ _ _ _ _” will be displayed.  
Operation Procedure  
1
2
1. When the MENU or MEMORY screen  
cd  
m
2
ESC  
Lv  
x
34. 22  
0 . 3958  
0 . 4060  
is displayed, press  
key to  
switch to the MEAS screen.  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
Non S t dNon on  
2.  
Press  
key to show  
DISPLAY  
cd  
2
2
Lv  
x
34  
3958  
4059  
.
34  
m
absolute value (ABS) or color  
difference (DIFF) to select.  
0
.
.
y
0
cd  
m
Lv  
+
0
.
.
1188  
35  
0000  
0001  
%
Lv  
100  
%
Measurement value switches between that for  
x
.
.
0
0
.
.
y
absolute value (ABS) and difference (DIFF)  
DISPLAY  
while  
key is pressed.  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
Non S t dNon on  
rm  
The setting of absolute value (ABS) and difference  
(DIFF) is saved even after switching OFF (O).  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When Using Closeup Lens  
Use the closeup lens in the optional accessories to measure a fine surface. For the  
attachment of the closeup lens, refer to the instruction manual for the closeup lens.  
If the closeup lens is attached, the measurement value must be compensated for the lens  
transmittance. This compensation coefficient is attached to the closeup lens. Use the data  
management software CS-Sꢀ0w Professional supplied with the CS-2000 as standard to  
set the coefficient in this instrument. After that, when the closeup lens is selected as lens  
type, the measurement value compensated with the compensation coefficient can be  
obtained. See instruction manual of CS-Sꢀ0w for details.  
The wrong setting of lens type leads to inaccurate measurement.  
Do not use the closeup lens with the ND filter. It leads to inaccurate measurement.  
* Lens type  
: STANDARD, CLOSE-UP  
* Factory default setting : STANDARD  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
MENU  
key when the MEAS  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
screen is displayed.  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
I n t S t dNon on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
OPTION  
[OPTION] and then press  
key.  
ENTER  
USER. CAL  
LENS  
NON  
STD  
NON  
ND FILTER  
The MENU – OPTION screen appears.  
The current set contents are displayed in the  
[LENS] item.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Press either  
or  
key to select  
key.  
OPTION  
LENS  
[LENS] and then press  
ENTER  
STANDARD  
CLOSE UP  
The MENU - SETUP – LENS (Lens type  
selection) screen appears.  
4. Press either  
[CLOSE-UP].  
or  
key to select  
OPTION  
LENS  
STANDARD  
CLOSE UP  
When you removed the closeup lens, select  
[STANDARD].  
5. Press  
key.  
ENTER  
OPTION  
USER. CAL  
LENS  
NON  
C UP  
NON  
When the lens type is set, the MENU - OPTION  
screen appears again on the LCD.  
ND FILTER  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - OPTION screen appears  
again on the LCD.  
Lens type setting is saved even after switching  
OFF (O).  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
The MEAS screen appears again on the LCD.  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
I n t C UNon on  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When Using ND Filter  
Use the ND filter in the optional accessories when measuring a high-luminance object.  
If the ND filter is attached, the measurement value must be compensated for the filter  
transmittance. This compensation coefficient is attached to the ND filter. Use the data management  
software CS-Sꢀ0w Professional supplied with the CS-2000 as standard to set the coefficient in this  
instrument. After that, when the ND filter is selected, the measurement value compensated with the  
compensation coefficient can be obtained. See instruction manual of CS-Sꢀ0w for details.  
The wrong setting of ND filter leads to inaccurate measurement.  
Do not use the ND filter with the closeup lens. It leads to inaccurate measurement.  
Note that an extra ND filter is built into this instrument. There are three setting options for use or  
non-use of this built-in ND filter: [AUTO] for switching automatically depending on the luminance of  
the object, [OFF] for constant non-use, and [ON] for constant use (See p.3ꢀ to p.33).  
* ND-FILTER  
: NONE, NDꢀ0, NDꢀ00  
* Factory default setting: NONE  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
MENU  
key when the MEAS  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
screen is displayed.  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
I n t S t dNon on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
OPTION  
USER. CAL  
LENS  
NON  
STD  
NON  
[OPTION] and then press  
key.  
ENTER  
ND FILTER  
The MENU – OPTION screen appears.  
The current set contents are displayed in the  
[ND-FILTER] item.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Press either  
or  
key to select  
OPTION  
FILTER  
N
D
[ND-FILTER] and then press  
key.  
ENTER  
NONE  
N
N
D
D
10  
The MENU - SETUP – ND-FILTER (ND filter  
100  
selection) screen appears.  
4. Press either  
or  
key to select  
OPTION  
D
N
FILTER  
[NONE], [ND 10] or [ND 100].  
NONE  
N
N
D
D
10  
100  
5. Press  
key.  
ENTER  
OPTION  
USER. CAL  
LENS  
NON  
STD  
10  
When the ND filter is set, the MENU - OPTION  
screen appears again on the LCD.  
ND FILTER  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - OPTION screen appears  
again on the LCD.  
ND filter setting is saved even after switching  
OFF (O).  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
The MEAS screen appears again on the LCD.  
2
Lv  
x
35. 93  
0 . 3968  
y
Ob  
0 . 4060  
I n t S t d 10 on  
s
SPD SYNC LEN ND BL  
r
2
˚ N  
m
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Calibration  
Calibration Channel  
This instrument includes calibration channels from Ch00 to Chꢀ0.  
Ch00 is for measurement based upon KONICA MINOLTA’s calibration standard. Its  
calibration correction coefficient has been set and is unchangeable.  
The following contents can be set to Ch0ꢀ to Chꢀ0 respectively using data management  
software CS-Sꢀ0w Professional supplied with the CS-2000 as standard. See instruction  
manual of CS-Sꢀ0w for details.  
Correction coefficient of user calibration  
Correction coefficient ID  
They are commonly used among each color space of Lvxy, Lvu’v’, LvTuv, XYZ, dominant  
wavelength/excitation purity and spectral graph in one channel.  
Calibration channels can be changed using the following procedure.  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
MENU  
key when the MEAS  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
screen is displayed.  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t d 10 on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
OPTION  
USER. CAL  
[OPTION] and then press  
key.  
NON  
STD  
10  
ENTER  
LENS  
ND FILTER  
The MENU – OPTION screen appears.  
The current set contents are displayed in the  
[USER.CAL] item.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Press either  
or  
key to select  
OPTION  
USER. CAL  
[USER.CAL] and then press  
key.  
ENTER  
CAL NO,  
NON  
The MENU - SETUP – USER.CAL (Calibration  
channel selection) screen appears.  
The calibration channel number and  
compensation coefficient ID (with a maximum of  
ꢀ0 letters) are displayed. In case of Ch00,  
“NON” is displayed. See instruction manual of  
CS-Sꢀ0w for details.  
4. Press either  
channel.  
or  
key to select the  
OPTION  
USER. CAL  
CAL NO,  
03  
key for larger number.  
key for smaller number.  
The calibration channel numbers can be  
selected among NON, and 0ꢀ to ꢀ0.  
5. Press  
key.  
ENTER  
OPTION  
USER. CAL  
03  
STD  
10  
When the calibration channel is set, the MENU -  
OPTION screen appears again on the LCD.  
If the calibration channel without compensation  
coefficient setting is selected, the setting will not  
be possible.  
LENS  
ND FILTER  
ESC  
By pressing  
key, after the setting is  
canceled the MENU - OPTION screen appears  
again on the LCD.  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
2
Lv  
x
35. 93  
The MEAS screen appears again on the LCD.  
0 . 3968  
y
Ob  
0 . 4060  
s
SPD SYNC LEN ND BL  
r
2
˚ N  
m
No  
n
S t d 10 on  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Backlight ON/OFF During Measurement  
The LCD backlight can be selectively turned on or off during measurement.  
If the backlight is turned off, LCD backlight reflection on the surrounding area  
affecting the measurement value during measurement can be avoided.  
If pressing the BACKLIGHT key to turn off the backlight, while the MEAS screen is  
displayed, the backlight is forcibly turned off independently of the following setting.  
* Factory default setting : ON  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
MENU  
key when the MEAS  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
screen is displayed.  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t d 10 on  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
key.  
SETUP  
OBSERVER  
BACKLIGHT  
2
°
[SETUP] and then press  
ENTER  
@
MEAS  
O
The MENU – SETUP screen appears.  
N
F
DATA FORM  
The current set contents are displayed in the  
[BACKLIGHT@MEAS] item.  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Press either  
or  
key to select  
SETUP  
BACKLIGHT  
@
MEAS  
[BACKLIGHT@MEAS] and then press  
O
O
FF  
N
key.  
ENTER  
The MENU - SETUP - BACKLIGHT@MEAS  
(Turning ON/OFF backlight during  
measurement) screen appears on the LCD.  
4. Press either  
[ON] or [OFF].  
or  
key to select  
5. Press  
ENTER  
key.  
SETUP  
OBSERVER  
BACKLIGHT  
2
°
When the setting is made to turn the backlight  
on or off during measurement, the MENU -  
SETUP screen appears again on the LCD.  
@
MEAS  
O
FF  
DATA FORM  
F
ESC  
By pressing  
key, after the setting is  
canceled the MENU - SETUP screen appears  
again on the LCD.  
Setting of backlight ON/OFF during  
measurement is saved even after switching OFF  
(O).  
6. Press  
key.  
ENTER  
The MENU screen appears again on the LCD.  
7
. Press  
key.  
ESC  
cd  
m
The MEAS screen appears again on the LCD.  
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t d 10 off  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurement  
5ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurement  
Operation Procedure  
5
6
2
1, 4  
3
1.  
Decide whether you use closeup lens  
(optional accessory) or not according to  
measuring object size and distance.  
See the table below for details on measuring distance  
and measuring area. If you set the closeup lens, lens  
type setting is required in this instrument. (See p.43)  
(Unit: mm)  
Measuring distance and measuring area  
Measuring area  
when the measuring  
distance is 500 mm ø distance is ꢀ,000 mm ø  
Measuring area  
when the measuring  
Minimum measurement  
diameter ø  
Maximum measurement  
diameter ø  
Minimum  
measurement area  
Maximum  
measurement area  
(Measuring  
angle)  
ꢀ° 0.2° 0.ꢀ° ꢀ° 0.2° 0.ꢀ° ꢀ° 0.2° 0.ꢀ° ꢀ° 0.2° 0.ꢀ° ꢀ° 0.2° 0.ꢀ°  
ꢀ° 0.2° 0.ꢀ°  
Without  
5.00 ꢀ.00 0.50  
350  
7.78 ꢀ.56 0.78 ꢀ6.66 3.33 ꢀ.67  
closeup lens  
With closeup  
lens  
ꢀ.00 0.20 0.ꢀ0 ꢀ.39 0.28 0.ꢀ4  
55.0  
70.9  
*Measurement distance is the distance from the front edge of the metal lens barrel or closeup lens ring.  
2.  
Rotate the measuring angle selector  
according to size of object and  
1°  
0.2°  
0.1°  
measurement distance, and set the  
aperture to 1°, 0.2°, or 0.1°.  
Do not operate the measuring angle selector during  
measurement. If measuring angle is switched  
during measurement, you may fail to perform  
measurement or to obtain correct measurement  
value. To rotate the measuring angle selector, move  
to a position where you can confirm the click. If you  
stop the selector in a halfway position,  
measurement may not be performed or wrong  
measurement values may be obtained.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.  
4.  
Rotate the diopter adjustment ring for  
adjustment of diopter.  
Make sure that aperture (black circle indicating  
measurement area) looks clear when observing  
object through finder. (See p.ꢀ5)  
Rotate the focus adjustment ring for  
objective lens for that purpose.  
Make sure that object around aperture looks  
clear when observing object through finder.  
Only measuring area for measuring object must be  
placed in aperture. If extra area, which is not  
measuring object, is included in aperture, you  
cannot perform correct measurement.  
5.  
6.  
When the MENU or MEMORY screen  
cd  
m
2
Lv  
x
is displayed, press  
key to  
ESC  
switch to the MEAS screen.  
The MEAS (Measurement value) screen  
appears.  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
Press the measurement button.  
When the measurement time is long, the  
measurement progress bar is displayed on the  
LCD until measurement is complete.  
Display during measurement  
(Single measurement/when  
measurement time is long)  
If the measurement time is set to options other  
than [MANUAL], the measurement time will be  
determined after the approximate luminance is  
checked inside the measurement device. For  
this reason, it may take several seconds until  
the measurement time appears. The displayed  
time shows approximately how long it will take  
from the point of time display to the end of  
measurement.  
MEASURING  
177s  
ESC  
:
STOP  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
No S t dNo off  
r
m
n
n
(Single measurement/when  
measurement time is short)  
cd  
m
2
Lv  
x
36. 20  
0 . 3968  
0 . 4056  
If the measurement time determined from the  
approximate luminance is short, the remaining  
time will not be displayed.  
y
Ob  
s
SPD SYNC LEN ND BL  
2˚ N  
r
m
No  
n
S t dNo  
n
off  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display during measurementt  
(Continuous measurement/when  
measurement time is long)  
CONT  
When the measuring button is pressed and held  
for two or more seconds, continuous  
measurement is conducted.  
When the measurement time is long, the  
measurement progress bar appears with the  
latest measurement value. The displayed time  
shows the remaining time, same as for the  
single measurement.  
MEASURING  
17s  
ESC  
:
STOP  
cd  
2
Lv  
x
13 . 17  
0 . 3966  
0 . 3905  
m
y
Obs  
2˚ N  
SPD SYNC LEN ND BL  
No S t dNo off  
When the measurement time is short, the  
measurement progress bar does not appear, but  
the measurement value is sequentially updated  
and displayed.  
r
m
n
n
(Continuous measurement/when  
measurement time is short)  
cd  
2
Lv  
x
36. 20  
0 . 3968  
0 . 4056  
ESC  
When  
key is pressed during continuous  
m
measurement, measurement is stopped. In this  
case, the measurement that is ongoing when  
ESC  
key is pressed will be canceled, and the  
last obtained measurement value will be  
ESC  
y
Ob  
s
SPD SYNC LEN ND BL  
2˚ N  
r
m
No  
n
S t dNo  
n
off  
displayed. If  
key is pressed in the middle  
of the first measurement, the measurement  
value will not be displayed.  
ENTER  
When  
key is pressed while the  
MEASURE  
measurement value is displayed, the  
ANGLE  
SPEED  
SYNC  
LENS  
1. 0  
˚
RMAL  
N
N
O
measurement properties are displayed so that  
the measurement conditions can be confirmed.  
When the measuring button or a random key is  
pressed, the MEAS screen appears again.  
O
SYNC  
STANDARD  
FILTER NONE  
IN ND  
OFF  
INTG  
66. 667  
m
s
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Saving the Measurement Value  
This instrument can save ꢀ00 measurement values with designated numbers from 00 to 99.  
Operation Procedure  
2, 3  
1
1. When the MEAS screen is displayed,  
MEAS  
cd  
2
m
Lv  
x
36 . 20  
0 . 3968  
0 . 4056  
press  
key to switch to the  
MEMORY  
y
MEMORY screen.  
The MEMORY (Memory data) screen appears.  
MEMORY 00  
cd  
2
Lv  
x
34 . 22  
0 . 3958  
0 . 4060  
m
y
The memory data number oo is displayd.  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
No S t dNo off  
r
m
n
n
2. Press either  
or  
key to select the  
MEAS  
cd  
2
Lv  
x
36 . 20  
0 . 3968  
0 . 4056  
m
m
number of memory data.  
key for larger number.  
y
MEMORY 02  
cd  
2
Lv  
x
y
key for smaller number.  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
No S t dNo off  
r
m
n
n
3. Press  
key.  
ENTER  
MEAS  
cd  
2
Lv  
36 . 20  
0 . 3968  
0 . 4056  
m
m
x
y
Each measurement value is saved with the  
selected number.  
MEMORY 02  
cd  
2
ESC  
If  
key is pressed, saving is canceled and  
Lv  
x
y
36 . 20  
0 . 3968  
0 . 4056  
the MEAS screen appears on the LCD.  
Ob  
2
s
˚ N  
SPD SYNC LEN ND BL  
No S t dNo off  
r
m
n
n
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Use the following procedure to display the memory data properties (measurement  
conditions):  
Operation Procedure  
5, 6  
1
2, 3, 4  
cd  
m
MENU  
screen is displayed.  
1. Press  
key when the MEAS  
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
The MENU screen appears.  
When the backlight of the LCD has been turned  
BACKLIGHT  
the backlight is turned on.  
y
Ob  
off via  
key on the MEAS screen,  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
MEMORY  
DELETE  
[MEMORY] and then press  
key.  
ENTER  
PROPERTIES  
The MENU – MEMORY screen appears.  
3. Press either  
or  
key to select  
MEMORY  
PROPERTIES  
[PROPERTIES] and then press  
MEMORY 00  
ANGLE  
SPEED  
SYNC  
LENS  
1. 0  
RMAL  
SYNC  
STANDARD  
˚
key.  
ENTER  
N
O
N
O
The MENU – MEMORY – PROPERTIES  
(Memory data measurement condition  
confirmation) screen appears.  
FILTER NONE  
IN ND  
OFF  
INTG  
66. 667  
ms  
The memory data number 00 is displayed.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. To display the memory data for  
another number, press either  
MEMORY  
PROPERTIES  
or  
MEMORY 02  
ANGLE  
SPEED  
SYNC  
LENS  
1. 0  
RMAL  
SYNC  
STANDARD  
˚
key to change the memory data  
number.  
The properties of the selected memory data are  
displayed, and the measurement conditions can  
be confirmed.  
N
O
N
O
FILTER NONE  
IN ND  
OFF  
INTG  
66. 667  
ms  
key for larger number.  
If kept pressed, the value continuously changes.  
key for smaller number.  
If kept pressed, the value continuously changes.  
5. Press  
key.  
ESC  
The MENU – MEMORY screen appears again  
on the LCD.  
6. Press  
key.  
ESC  
The MEAS screen appears again on the LCD.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Deleting the Memory Data  
Stored measurement values can be deleted in the following procedure.  
Operation Procedure  
5, 6, 7  
1
2, 3, 4, 5  
MENU  
key when the MEAS  
screen is displayed.  
1.  
Press  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
The MENU screen appears.  
When the backlight of the LCD has been turned  
BACKLIGHT  
off via  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
the backlight is turned on.  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2.  
3.  
Press either  
[MEMORY] and then press  
key.  
or  
key to select  
MEMORY  
DELETE  
ENTER  
PROPERTIES  
The MENU – MEMORY screen appears.  
Press either  
[DELETE] and then press  
key.  
or  
key to select  
MEMORY  
MEM, DELETE  
ENTER  
MEM, DATA N  
O
, 00  
Lv  
x
y
34 . 22  
0 . 3958  
0 . 4060  
The MENU – MEMORY – DELETE (Memory  
data deletion) screen appears.  
The memory data number 00 is displayed.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.  
Press either  
number of memory data you want to  
delete.  
key for larger number. If kept pressed, the  
value continuously changes. [ALL] is displayed  
after No.99.  
or  
key to select the  
MEMORY  
MEM, DELETE  
MEM, DATA N  
O
, 02  
Lv  
x
36 . 20  
0 . 3968  
0 . 4056  
y
key for smaller number. If kept pressed, the  
value continuously changes. [ALL] is displayed  
after No.00.  
The deleted memory data can not be recovered.  
Confirm the number before deleting the memory  
data.  
5-a-1. Deletion of saved data, one by one:  
Select the number of the memory  
data to be deleted, and press  
MEMORY  
MEM, DELETE  
MEM, DATA NO , 02  
Lv  
x
y
key.  
ENTER  
The saved measurement value disappears.  
ESC  
By pressing  
key, the deletion of the  
memory data is canceled and the MENU -  
MEMORY screen appears again on the LCD.  
5-a-2. Repeat the steps 4 through 5-a-1.  
as necessary.  
5-a-3. Press  
key.  
ESC  
The MENU – MEMORY screen appears  
again on the LCD.  
5-b-1. Collective deletion of all memory  
data:  
MEMORY  
MEM, DELETE  
MEM, DATA N  
O
, ALL  
Select [ALL] and press  
key.  
ENTER  
Lv  
x
y
36 . 20  
0 . 3968  
0 . 4056  
The confirmation screen for deletion of all  
memory data is displayed.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-b-2. Press  
key to select [OK] and  
then press ENTER key.  
MEMORY  
MEM, DELETE  
DELETE  
DELETE  
ALL DATA  
All memory data are deleted, and the MENU -  
?
MEMORY screen appears again on the LCD.  
O
K
CANCEL  
ESC  
By selecting [CANCEL] and pressing  
ENTER  
key, or pressing  
key, the deletion of  
all memory data is canceled and the MENU -  
MEMORY screen appears again on the LCD.  
6. Press ESC key.  
The MENU – MEMORY screen appears again  
on the LCD.  
7
. Press ESC key.  
The MEAS screen appears again on the LCD.  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering Target Color  
Target color  
The target color serves as reference for measurement of deviation of measured color from  
reference.  
Target colors can be registered up to 20 from Ch 0ꢀ to Ch 20 completely within this  
instrument.  
To register the target color:  
(ꢀ) Register the measurement value  
(2) Select from the memory data  
(3) Enter the numerical value  
To change the previously set target color, select another target color. User calibration  
correction coefficient will not be influenced despite of target color change.  
The target color is commonly used among each color space of Lvxy, Lvu’v’, LvTΔuv, XYZ,  
dominant wavelength/excitation purity and spectral graph.  
Operation Procedure  
10, 11  
1
2, 3, 4, 5,  
6, 7, 8, 9  
MENU  
key when the MEAS  
screen is displayed.  
1.  
Press  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
The MENU screen appears.  
When the backlight of the LCD has been turned  
BACKLIGHT  
off via  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
the backlight is turned on.  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
6ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.  
3.  
Press either  
[TARGET] and then press  
key.  
or  
key to select  
TARGET  
SELECT  
ENTER  
SET  
DELETE  
The MENU – TARGET screen appears.  
Press either  
[SET] and then press  
or  
key to select  
key.  
TARGET  
TARGET SET  
TARGET Ch 01  
ENTER  
The MENU – TARGET – SET screen appears.  
Lv  
x
y
4. Change target color channels by  
pressing  
or  
key, and select the  
channel used to register a target color.  
key for larger number. If kept pressed, the  
number continuously increases.  
key for smaller number. If kept pressed, the  
number continuously decreases.  
Once a target color is registered, the status  
before registration cannot be restored. If the  
target colors are changed by overwriting, confirm  
the channel number before making the change.  
5. Press  
key.  
ENTER  
TARGET  
TARGET SET  
TARGET Ch 04  
The screen used for input of the target color ID  
appears on the LCD.  
Lv  
x
y
6. Enter the target color ID.  
TARGET  
TARGET SET  
TARGET Ch 04  
When the  
key is pressed, the characters  
s
ample  
change among 0 to 9, a to z, A to Z, and space.  
When the key is pressed, the characters  
change among space, Z to A, z to a, and 9 to 0.  
When key is pressed, the cursor moves to  
the right by one position.  
Lv  
x
y
When  
key is pressed, the cursor moves to  
the left by one position.  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
. Press  
key.  
ENTER  
TARGET  
TARGET SET  
TARGET Ch 04  
The screen used to select a target color  
s
ample  
SOURCE MES  
<
>
appears on the LCD.  
ESC  
By pressing  
key, the input of the target  
Lv  
x
y
36  
3968  
4056  
.
20  
0
0
.
.
color is canceled and the MENU - TARGET  
screen appears again on the LCD.  
8. Press either  
or  
key to select  
data to be a target color.  
When the  
key is pressed, values are  
changed among, M00 to M99, EDT, and MES. If  
kept pressed, the value continuously changes.  
When the  
key is pressed, values are  
changed among MES, EDT, and M00 to M99. If  
kept pressed, the value continuously changes.  
9-a-1. Selection of a measurement value  
as a target color:  
TARGET  
TARGET SET  
TARGET Ch 04  
ample  
SOURCE MES  
s
<
>
Select [MES] and press  
key.  
ENTER  
Lv  
x
36  
3968  
4056  
.
20  
0
0
.
.
y
When the target color is registered, the MENU  
- TARGET screen appears again on the LCD.  
ESC  
By pressing  
key, the registration of the  
target color is canceled and the MENU -  
TARGET screen appears again on the LCD.  
9-b-1. Selection of a memory data as a  
TARGET  
TARGET SET  
TARGET Ch 04  
ample  
SOURCE M00  
target color:  
s
<
>
Select from [M00~M99] and press  
key.  
Lv  
x
y
35  
3968  
4060  
.
93  
ENTER  
0
0
.
.
When the target color is registered, the MENU  
- TARGET screen appears again on the LCD.  
ESC  
By pressing  
key, the registration of the  
target color is canceled and the MENU -  
TARGET screen appears again on the LCD.  
9-c-1. Manual input of a target color:  
TARGET  
TARGET SET  
TARGET Ch 04  
ample  
SOURCE EDT  
Select [EDT] and press  
key.  
ENTER  
s
<
>
Lv  
x
y
0
.
0000E  
+0  
The screen used to input a target color with  
a numerical value appears on the LCD.  
0
.
.
0000  
0000  
0
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9-c-2. Enter the target color.  
TARGET  
TARGET SET  
TARGET Ch 04  
key for larger number.  
s
ample  
SOURCE EDT  
<
>
If kept pressed, the value continuously  
increases.  
key for smaller number.  
Lv  
x
y
0
.
6200E  
+1  
0
.
.
3968  
4000  
0
If kept pressed, the value continuously  
becomes small.  
When  
key is pressed, the cursor moves  
to the right by one position.  
When  
key is pressed, the cursor moves  
to the left by one position.  
9-c-3. Press  
key.  
ENTER  
When the target color is registered, the  
MENU - TARGET screen appears again on  
the LCD.  
When observer angle is ꢀ0°, Y is displayed  
instead of Lv and registered as Yꢀ0.  
If the entered value does not establish a  
proper combination with the value in the  
color space mode, the cursor will move to  
the first digit on the first line. Enter another  
value again.  
ESC  
By pressing  
key, the registration of the  
target color is canceled and the MENU -  
TARGET screen appears again on the LCD.  
10. Press ESC key.  
The MENU screen appears again on the LCD.  
11. Press ESC key.  
The MEAS screen appears again on the LCD.  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting Target Color  
Select a target color for color-difference measurement from the channels Ch0ꢀ to Ch20.  
The new set color is also applied to the measurement value displayed on the current  
MEAS screen.  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
key when the MEAS  
screen is displayed.  
MENU  
cd  
m
2
Lv  
x
36 . 20  
0 . 3968  
0 . 4056  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
TARGET  
SELECT  
[TARGET] and then press  
key.  
ENTER  
SET  
DELETE  
The MENU – TARGET screen appears.  
3. Press either  
or  
[SELECT] and then press  
key.  
key to select  
TARGET  
TARGET SELECT  
TARGET Ch01  
ENTER  
Lv  
x
y
The MENU – TARGET – SELECT screen  
appears.  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Press either  
or  
key to switch  
TARGET  
TARGET SELECT  
TARGET Ch04  
the target color channel.  
key for larger number.  
s
ample  
Lv  
x
y
36  
3968  
4056  
.
20  
If kept pressed, the number continuously  
increases.  
0
0
.
.
key for smaller number.  
If kept pressed, the number continuously  
decreases.  
5. Press  
key.  
ENTER  
When the target color is set, the MENU -  
TARGET screen appears again on the LCD.  
ESC  
By pressing  
key, the selection of the  
target color is canceled and the MENU -  
TARGET screen appears again on the LCD.  
6. Press  
key.  
ESC  
The MENU screen appears again on the LCD.  
cd  
m
7
. Press ESC key.  
2
Lv  
x
36 . 20  
0 . 3968  
0 . 4056  
The MEAS screen appears again on the LCD.  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Deleting Target Color  
The registered target color can be deleted in the following procedure.  
Operation Procedure  
6, 7  
1
2, 3, 4, 5  
1. Press  
key when the MEAS  
screen is displayed.  
MENU  
cd  
m
2
Lv  
x
35. 93  
0 . 3968  
0 . 4060  
The MENU screen appears.  
When the backlight of the LCD has been turned  
off via  
the backlight is turned on.  
BACKLIGHT  
key on the MEAS screen,  
y
Ob  
s
SPD SYNC LEN ND BL  
2
˚ N  
r
m
No  
n
S t dNo  
n
off  
MEAS  
MEMORY  
TARGET  
OPTION  
SETUP  
2. Press either  
or  
key to select  
TARGET  
SELECT  
[TARGET] and then press  
key.  
ENTER  
SET  
DELETE  
The MENU – TARGET screen appears.  
3. Press either  
or  
[DELETE] and then press  
key.  
key to select  
TARGET  
TARGET DELETE  
TARGET Ch01  
ENTER  
Lv  
x
y
The MENU – TARGET – DELETE (Target  
color deletion) screen appears.  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Press either  
or  
key and select  
TARGET  
TARGET DELETE  
TARGET Ch04  
the number to delete the desirable  
s
ample  
memory data or [ALL]. Press  
key.  
key for larger number. If kept pressed, the  
value continuously changes. [ALL] is displayed  
after Ch 20.  
ENTER  
Lv  
x
y
36  
3968  
4056  
.
20  
0
0
.
.
key for smaller number. If kept pressed, the  
value continuously changes. [ALL] is displayed  
after Ch 00.  
The confirmation screen to delete the target  
color appears.  
5.-a-1. Deletion of target colors one by  
one:  
TARGET  
TARGET DELETE  
TARGET Ch04  
TARGET DELETE  
Press  
then press  
key to select [OK] and  
key.  
TARGET Ch 04  
ENTER  
OK  
CANCEL  
The display of the registered target color  
disappears.  
By selecting [CANCEL] and pressing  
ENTER  
ESC  
key, the  
key, or pressing  
deletion of the target color is canceled and  
the MENU - TARGET screen appears  
again on the LCD.  
5.-a-2. To delete another target color  
continuously, repeat the steps 4  
through 5-a-1. as necessary.  
5.-a-3. Press  
key.  
ESC  
The MENU – TARGET screen appears  
again on the LCD.  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TARGET  
TARGET DELETE  
TARGET ChALL  
TARGET DELETE  
5.-b-1. Collective deletion of all target  
colors:  
TARGET Ch ALL  
key to select [OK] and then  
OK  
CANCEL  
press  
key.  
ENTER  
When all target colors are deleted, the  
MENU - TARGET screen appears again on  
the LCD.  
By selecting [CANCEL] and pressing  
ENTER  
ESC  
key, the  
key, or pressing  
deletion of the target color is canceled and  
the MENU - TARGET screen appears  
again on the LCD.  
ESC  
By pressing  
key, the selection of the  
target color is canceled and the MENU -  
TARGET screen appears again on the  
LCD.  
6. Press  
key.  
ESC  
The MEAS screen appears again on the LCD.  
7
. Press  
key.  
ESC  
The MEAS screen appears again on the LCD.  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Communication  
7ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting to PC  
This instrument can be used together with PC for mutual communication. Use the USB  
cable (2m) CS-A32 supplied as standard accessory for this purpose.  
The USB cable is allowed to plug/unplug while power is on, but it is recommended to  
switch power off in this case.  
Operation Procedure  
1.  
2.  
Switch power OFF (O).  
Connect the USB cable to the USB  
connector of this instrument.  
3.  
Make sure that USB cable is all seated to  
the USB connector.  
Communication interface in this instrument conforms to USBꢀ.ꢀ.  
Hold the USB cable plug in unplugging. Do not pull the cord.  
Plug the USB cable to fit the connector entry point.  
To connect this instrument to PC, install the corresponding USB driver software. It is  
attached to the data management software CS-Sꢀ0w Professional in the standard  
accessories. See installation guide of CS-Sꢀ0w Professional for details on installing the  
USB driver software to PC.  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Remote Mode  
Remote mode refers to sending command from PC to this instrument with both connected.  
If this instrument is controlled with PC, “REMOTE MODE” appears on the LCD. While  
this message is displayed, key operation of this instrument is not acceptable except  
for following cases.  
If the measurement button is pressed, measurement starts to forward the data to  
PC. (in case that measurement button is in valid mode by transferring command  
from PC to this instrument. Use data management software below.)  
ESC  
When  
key is pressed, the remote mode is canceled.  
To control this instrument with PC, use the data management software CS-Sꢀ0w  
Professional in the standard accessories. See instruction manual of CS-Sꢀ0w Professional  
for details on the specifications and usage.  
If you want to use an independent program on PC to control this instrument, download  
Communication Specifications from KONICA MINOLTA’s website at URL below for your  
reference  
(The above URL is subject to change without notice.)  
(If the target page will not appear, please search the site by keywords, CS-2000 and  
download.)  
Key  
ESC  
Measurement button  
LCD screen  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Explanation  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurement Principle  
Light energy passes through the objective lens. The lights from the measurement area pass  
through the hole in the center of the aperture mirror to the optical fiber, while the remaining  
light is guided to the finder optics by the aperture mirror. As a result, the part equivalent to  
the measurement area looks like a black circle when observed through the finder.  
The light entering the optic fiber is reflected repeatedly so that it is mixed and becomes  
virtually uniform. It then passes through the collimator lens to the plane diffraction grating.  
After being dispersed by the grating, the light is focused by the condenser lens according  
to wavelength. An array sensor is located at this focus point.  
The amount of detected energy for each wavelength is then converted to a digital value by  
an A/D converter, based on which the spectral radiant luminance and chromaticity are  
calculated by the processing section of the CS-2000.  
Sensor Section  
The sensor section has a photo diode array consisting of 5ꢀ2 elements. The array is  
always kept at constant temperature using a Peltier cooler, irrespective of the ambient  
temperature. This can reduce dark current and improve S/N ratio, thus enabling  
measurement of low luminance.  
Objective lens  
Array sensor  
Condenser lens  
Aperture mirror Collimator lens  
Optical fiber  
Plane diffraction grating  
Shutter  
Dark Measurement  
Each measurement consists of “light measurement” and “dark measurement”.  
“Light measurement” is performed with light from the object irradiating the sensor, while  
“dark measurement” is performed with no light from the object irradiating the sensor, so  
that detector dark current is measured.  
When measurement starts, first “light measurement” is performed. When “light measurement”  
is complete, the shutter will close automatically, then “dark measurement” starts immediately.  
“Dark measurement” is performed with the same integration time used for “light measurement”.  
The final measured data is obtained by subtracting the measured data obtained in “dark  
measurement” from the one obtained in “light measurement”. This method eliminates  
influences of dark current of the array sensor, resulting in improved measurement accuracy.  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LvTΔuv  
Following factors can be acquired as measurement value with LvTΔuv as color space of this instrument.  
Lv  
T
: Luminance  
:Correlated color temperature  
Δuv :Color difference from blackbody locus  
While Lvs stands for luminance, T and Δuv for color in LvTΔuv.  
<Relation between correlated color temperature T and color difference from blackbody locus Δuv>  
Color temperature refers to the temperature of black body (perfect radiator) which has  
equal chromaticity coordinates to certain light. However, color temperature only represents  
colors on blackbody locus.  
Correlated color temperature, slightly wider interpretation of color temperature, is very  
useful to eliminate such problem. Here, correlated color temperature covers those which  
are slightly outside the range of that of blackbody locus.  
If a certain color positions on isotemperature line, the intersection point of isotemperature  
line and blackbody locus is indicated as correlated color temperature for the color.  
Isotemperature line means line on chromaticity coordinates which is a set of colors visually  
close to color temperature on blackbody locus.  
However, since all colors on a color-matching temperature line are represented with equal  
correlated color temperature, it is not possible to describe color only with correlated color  
temperature. To solve that, Δuv, deviation of correlated color temperature T from  
blackbody locus, is to apply for that purpose.  
If Δuv exists above blackbody locus, it is represented with “+”, and below, with “-”.  
v
Blackbody locus  
0.35  
Correlated  
temperature T  
Δuv  
0.30  
u
Correlated temperature T and Δuv  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dominant wavelength/Excitation purity  
In the x, y chromaticity diagram shown below, the curve VScSR is the spectrum locus, and  
point N is the white point.  
Colors located in the region enclosed by the spectrum locus and the straight lines VN and  
NR are referred to as spectral colors; colors located in the triangle NVR with the white point  
N at the apex and the pure purple line VR as the base are referred to as nonspectral colors.  
<Dominant wavelength and excitation purity (spectral colors)>  
When the chromaticity point obtained by the measurement is C, the wavelength  
corresponding to the intersection point S of the extension of NC with the spectrum locus  
(curve VScSR) is referred to as the dominant wavelength and indicated by the symbol λd.  
The ratio of the lengths of the straight lines NC and NS is referred to as the excitation  
purity of color excitation C and indicated by the symbol pe.  
<Complementary wavelength (non-spectral colors)>  
When the chromaticity point obtained by measurement is C', the extension of NC' toward C'  
does not intersect with the spectrum locus but only the pure-purple lines. In this case the  
wavelength corresponding to the intersection point Sc of the extension of NC' toward N with the  
spectrum locus is referred to as the complementary wavelength and indicated by the symbol λc.  
When the intersection point of the extension of the line NC' with the line VR (pure-purple  
locus) is designated by S', the ratio of the lengths of NC' to NS' is referred to as excitation  
purity and indicated by the symbol p'v.  
The following equations are formulated, if each point is designated as the following  
coordinates: (xn, yn): chromaticity coordinate of point N; (xc, yc): chromaticity coordinate of  
point C; (xλ, yλ): chromaticity coordinate of point S, (xc', yc): chromaticity coordinate of  
point C', and (xp, yp): chromaticity coordinate of point:  
y
Excitation purity (spectral colors)  
Spectrum locus  
Sc  
xc – xn  
x – xn  
yc – yn  
y – yn  
pe =  
=
0.8  
0.6  
0.4  
0.2  
0
550 nm  
Excitation purity (non-spectral colors)  
S
xc'– xn  
xp – xn  
yc' – yn  
yp – yn  
pe' =  
=
500 nm  
C
N
600 nm  
White point  
R
780 nm  
C'  
S'  
Pure purple line  
V
380 nm  
0.2  
0.4  
0.6  
x
Dominant wavelength on chromaticity diagram  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Measurement of Object Color  
Use of the data management software CS-Sꢀ0w Professional in the standard accessories  
enables simple measurement of the color of the object. Measured data is evaluated based  
on luminance which has been stored as light source data in CS-Sꢀ0w. See instruction  
manual of CS-Sꢀ0w for details.  
Set while calibration plate (optional accessory) and object on the same position with  
the same angle from this instrument. Uniform illumination and measurement conditions  
of white calibration plate and those of object. If not, measurement data may vary,  
causing incorrect data.  
Keep illumination light source as stable as possible with fixed voltage power source  
during measurement.  
Measurement Procedure  
Necessary Setting for Object Color Measurement  
1.  
Set one or more tungsten lumps  
or equivalent as illumination  
source toward white calibration  
plate as in the right illustration.  
Set this instrument vertical to white  
calibration plate.  
Illumination Light Source  
White Calibration  
Plate  
45°  
45°  
Keep the angle between illumination  
light source and white calibration plate  
at 45°.  
2.  
Start up this instrument, PC, and  
software CS-S10w.  
Illumination Light Source  
White Calibration  
3.  
4.  
Set the document type to “object color” with CS-S10w.  
Conduct white calibration with CS-S10w.  
Measurement of Object  
5.  
6.  
Set object on the same position and at the same angle as white  
calibration plate.  
Conduct measurement with CS-S10w.  
See instruction manual of data management software CS-Sꢀ0w for details.  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Dimensions  
(Unit: mm)  
Filter screw  
diameter  
ø52  
120.5  
129  
58.5  
300  
392  
Measurement  
distance reference  
Mounting screw M5 Mounting screw M5  
Depth 6.5mm Depth 6.5mm  
95.7  
229.5  
ø15  
6
Optical  
axis  
Positioning pin hole 1  
ø5mm Depth 4 mm  
Positioning pin hole 2  
Depth 4mm  
70  
170  
Tripod screw (3/8 inches screw)  
Depth 10.5 mm  
190.4  
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Error Message  
Error message appears on the LCD when this instrument does not operate normally. Below  
table shows type of error message, its description and corrective action respectively.  
Error Message  
Cause (Description)  
Corrective action  
Data stored in ROM is  
damaged.  
2
MEMORY ERROR  
Turn on the power switch again.  
If the symptoms are not remedied,  
please contact the nearest  
KONICA MINOLTA  
authorized service facility.  
Luminance of measuring  
object is higher than the  
available range.  
• Use the ND filter and re-measure.  
• Decrease the measuring area and  
re-measure.  
OVER  
• If the symptoms are not remedied,  
please contact the nearest  
KONICA MINOLTA authorized  
service facility.  
Flicker of measuring object  
is high.  
• Set the flicker cycle in INT SYNC  
mode, or input the flicker signal in  
EXT SYNC mode.  
Input signal in EXT SYNC  
mode is not at CMOS level.  
• Input a signal with 3.5 to 5.0 V at  
high level; 0.0 to ꢀ.5 V at low level.  
3
SYNC ERROR  
Input signal in EXT SYNC  
mode exceeds 200 Hz.  
• Set the frequency value divided by  
an integer in INT SYNC mode and  
re-measure.  
Input signal in EXT SYNC  
mode is less than 20 Hz.  
• Set the integral multiple value of  
the input signal cycle in INT SYNC  
mode and re-measure using the  
MULTI INTEG-NORMAL mode or  
MULTI INTEG-FAST mode.  
Set the integral multiple value of the input  
signal cycle in INT SYNC mode and re-  
measure using the MANUAL mode.  
Measurement was  
performed when the  
measuring angle selector  
was in the wrong position,  
or its position was changed  
during measurement.  
• Switch the measuring angle  
selector and re-measure. Or, do  
not operate the measuring angle  
selector during measurement.  
• If the symptoms are not remedied,  
please contact the nearest  
KONICA MINOLTA authorized  
service facility.  
4
VIEWING-ANGLE  
SELECTOR ERROR  
The ambient temperature for the • Decrease the ambient temperature  
5
6
TEMPERATURE  
ERROR  
measurement device is too high,  
and an internal temperature of  
the sensor becomes abnormal.  
to enable cooling to within the  
specified temperature.  
The cooling fan stops, or the • Decrease the ambient temperature  
FAN ERROR  
cooling device has an error.  
to enable cooling to within the  
specified temperature.  
• Turn off the power switch once,  
turn it on again after a while.  
If the symptoms are not remedied, the  
fan must be repaired. Please contact  
the nearest KONICA MINOLTA  
authorized service facility.  
8ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Error Check  
Should any errors be found in this instrument, try the corrective actions shown in the  
following table. If this does not help, it’s possible the instrument is broken. Please  
contact the nearest KONICA MINOLTA authorized service facility with the error  
number and version of your instrument. To confirm the instrument version, see p.23.  
Error  
No.  
Reference  
Page  
Symptom  
Item to Check  
Corrective Action  
No display on the LCD Has the AC adapter been properly Connect the AC adapter.  
2ꢀ  
2ꢀ  
after power is turned  
on.  
plugged into the AC outlet?  
Has the AC adapter been  
Connect the AC adapter.  
connected to this instrument?  
Has a wrong AC adapter Be sure to use the AC adapter and  
been connected?  
power cord supplied as a standard  
or optional accessory (AC-A3ꢀ2).  
2ꢀ  
Is AC power source  
within rated scale?  
Use within ꢀ0% of the nominal  
voltage.  
2ꢀ  
8
2
Nothing is visible  
through the finder.  
Is the lens cap still attached Remove the lens cap.  
to the objective lens?  
Is the ND filter attached Use the ND filter when the  
to the objective lens?  
luminance of that being  
measured is too high.  
9, 45  
Is the ND eyepiece filter Use the ND eyepiece filter when  
attached to the finder?  
luminance of that being  
measured is too high.  
9, 45  
ꢀ4, 49  
49  
3
4
Nothing is displayed on Is the backlight set to  
Press BACKLIGHT key to turn  
ON the backlight.  
the LCD.  
OFF?  
Has the backlight been In the menu operation, set the  
set to OFF during  
measurement?  
backlight to ON during  
measurement  
Does not accept key  
operation.  
Has the remote mode  
been set?  
Press ESC key to cancel the  
remote mode.  
73  
Have you pressed a  
disabled key?  
Press the correct key.  
5
6
Measurement unavailable Has a screen other than Conduct measurement when the  
even if the measurement MENU been displayed? MEAS screen is displayed.  
button is pressed.  
53  
The entered value for  
target color is different  
from the one that will be  
displayed after setting.  
A ꢀ-digit difference may be  
found due to calculation error.  
6ꢀ  
52  
7
Measurement values  
do not appear.  
Is there data?  
Conduct measurement.  
Has the color space  
mode become color  
temperature?  
Color temperature is displayed  
as "_ _ _" if it is far from the  
blackbody locus. Change the  
display using the other color  
space mode and check.  
39  
52  
Did you interrupt  
measurement?  
Conduct measurement again.  
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Error  
No.  
Reference  
Page  
Symptom  
Item to Check  
Corrective Action  
8
Measurement values  
are inconsistent.  
Is the measuring object Conduct measurement with the  
stable? measuring object stable.  
Is the measuring object Repeatability of x, y worsens if  
of low luminance?  
the measuring object of low  
luminance is measured.  
It especially worsens when the  
measurement angle is 0.2º or  
0.ꢀº.  
52, 30  
It also worsens when the  
measurement time is short.  
Make the measurement time  
longer.  
Is the measurement  
sync frequency  
Set the appropriate  
measurement sync frequency.  
appropriate when  
measuring the display?  
Use MULTI INTEG-NORMAL  
mode or MULTI INTEG-FAST  
mode.  
26, 30  
Measure in EXT SYNC mode.  
Have the ambient  
temperature and /or  
humidity changed  
rapidly?  
Conduct measurement under an  
environment free from rapid  
changes in ambient temperature  
and humidity.  
3
Did you start  
measurement  
immediately after  
startup?  
Allow the instrument to warm up  
for 20 minutes or more when the  
power switch is turned on.  
23  
9
Measurement values  
appear incorrectly.  
Is the objective lens  
clean?  
Wipe off the lens with a dry, soft  
cloth or lens cleaning paper.  
52  
47  
User calibration may not Check the values without user  
be performed correctly. calibration (i.e. set the calibration  
channel to 00 (NON) and check).  
Is the calibration  
channel correct?  
Select the calibration channel  
according to the light source of  
luminance and chroma close to  
the object.  
47  
Has the closeup lens  
been attached?  
Select the lens type setting  
according to the attached  
closeup lens.  
43, 52  
45  
Has the ND filter been  
attached?  
Select the ND filter setting  
according to the attached ND  
filter.  
Has the object been  
focused?  
Adjust the focus after adjusting  
the diopter.  
ꢀ3, ꢀ5  
52  
ꢀ0 The measurement  
Is the measuring object When measuring an object of  
stops halfway and does of high luminance?  
not finish in the set  
measurement time.  
high luminance, the sensor may  
be saturated by exceeding the  
upper limit of the current  
45  
measurement setting.  
Use the ND filter.  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Error  
No.  
Reference  
Page  
Symptom  
Item to Check  
Corrective Action  
ꢀꢀ Actual measurement  
time is different from  
the displayed  
The displayed measurement  
time is the remaining time. The  
actual measurement time may  
be different from the displayed  
time depending on the mode  
setting of measurement time.  
30  
measurement time.  
ꢀ2 Measurement value on Has the power source  
Connect to a stable power  
the LCD disappears.  
been supplied securely? source and insert the AC adapter  
plug securely.  
2ꢀ  
54  
Did you interrupt the  
measurement?  
When starting continuous  
measurement, press the  
measurement button securely.  
Do not press ESC key.  
ꢀ3 During USB  
communication:  
Has the USB cable  
been connected  
Connect this instrument and the  
PC securely.  
72  
Cannot download data securely?  
output from this  
instrument on the PC.  
Cannot enter  
Has the USB cable  
been disconnected?  
Replace the USB cable.  
commands or data from  
the PC to this  
instrument.  
Has remote mode been Send the connection command  
canceled?  
from the PC to this instrument  
and switch to remote mode. Use  
the data management software  
CS-Sꢀ0w in the standard  
accessories.  
73  
Has the program been  
prepared correctly?  
Refer to communication  
specifications and check the  
program. Use the data  
management software CS-Sꢀ0w  
in the standard accessories.  
ꢀ4 Same error message  
appears repeatedly.  
Check the appropriate  
If the symptoms are not  
corrective action for the remedied, please contact the  
error message.  
nearest KONICA MINOLTA  
authorized service facility.  
84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Initialization  
Preset measurement conditions can be initialized to the factory default settings according  
to the following procedure.  
Factory default settings are shown below.  
* Synchronizing method  
: NO SYNC  
* Measurement time  
* Display format  
: MULTI INTEG, ꢀs,  
IN-ND: AUTO  
* Observer  
: 2°OBS  
: Lvxy  
: ****.**** [F]  
* Color space mode  
* Absolute value (ABS)/  
Difference (DIFF) display  
: Absolute value (ABS)  
: NONE  
* Lens type  
: STANDARD  
* ND filter type  
* Backlight during measurement : ON  
Operation Procedure  
1, 2  
1
1. When the power switch is OFF (O),  
turn it to ON ( I ) while pressing  
key,  
key and  
key  
MEMORY  
simultaneously.  
The INITIALIZE SETTINGS (confirmation of  
setting initialization) screen appears approx.  
5 seconds after the initial screen on the LCD.  
RESET  
ALL SETTINGS ?  
MEMORY  
Continue pressing  
key until the INITIALIZE SETTINGS screen  
appears.  
key,  
key and  
OK  
CANCEL  
2. Press  
press  
key to select [OK] and then  
key.  
RESET  
ENTER  
ALL SETTINGS ?  
The preset measurement conditions are  
initialized and the MEAS screen appears on the  
LCD.  
OK  
CANCEL  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Switching Luminance Unit  
You can select [cd/m2] or [ fL ] as the luminance unit.  
Operation Procedure  
1
1, 2  
1. When the power switch is OFF (O),  
turn it to ON ( I ) while pressing  
key and  
simultaneously.  
key  
MENU  
fL  
cd  
m
The Luminance Unit (switching luminance  
unit) screen appears approx. 5 seconds after  
the initial screen on the LCD.  
MENU  
Continue pressing  
key and  
key until  
the Luminance Unit screen appears.  
2. Press either  
or  
key to select the  
luminance unit and then press  
key.  
ENTER  
The setting is entered and the MEAS screen  
appears on the LCD.  
86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Main Specifications  
Model  
CS-2000  
380 to 780 nm  
0.9 nm/pixel  
Wavelength range  
Wavelength resolution  
Display wavelength  
bandwidth  
ꢀ.0 nm  
Wavelength precision  
Spectral bandwidth  
0.3 nm (median wavelength: 435.8 nm, 546.ꢀ nm, 643.8 nm Hg-Cd lamp)  
5 nm or less (half bandwidth)  
Measuring angle (selectable)  
ꢀ°  
0.2°  
0.ꢀ°  
Measurement luminance range  
(Standard light source A)  
0.003 to 5,000 cd/m2  
0.075 to ꢀ25,000 cd/m2  
0.3 to 500,000 cd/m2  
ø5 mm  
øꢀ mm  
ø0.5 mm  
ø0.ꢀ mm when using closeup lens)  
Minimum measuring area  
(øꢀ mm when using closeup lens)  
ø0.2 mm when using closeup lens)  
Minimum measuring distance  
Minimum luminance display  
350 mm (55 mm when using closeup lens)  
0.00002 cd/m2  
Minimum spectral  
radiance display  
ꢀ.0×ꢀ0-9 W/sr, m2, nm  
Accuracy: Luminance  
(Standard light source A)*ꢀ  
2%  
x,y : 0.003 (0.003 to 0.005 cd/m2)  
x,y : 0.003 (0.075 to 0.ꢀ25 cd/m2)  
x,y : 0.002 (0.ꢀ25 to ꢀ.25 cd/m2)  
x,y : 0.003 (0.3 to 0.5 cd/m2)  
Accuracy: Chromaticity  
(Standard light source A)*ꢀ  
x,y : 0.002 (0.005 to 0.05 cd/m2)  
x,y : 0.002 (0.5 to 5 cd/m2)  
x
y
:
:
0.00ꢀ5 (0.05 cd/m2 or more)  
0.00ꢀ  
x
y
:
:
0.00ꢀ5(ꢀ.25 cd/m2 or more)  
0.00ꢀ  
x
y
:
:
0.00ꢀ5(5 cd/m2 or more)  
0.00ꢀ  
0.4% (0.003 to 0.05 cd/m2)  
0.3% (0.05 to 0.ꢀ cd/m2)  
0.ꢀ5% (0.ꢀ to 5,000 cd/m2)  
0.4% (0.075 to ꢀ.25 cd/m2)  
0.3% (ꢀ.25 to 2.5 cd/m2)  
0.ꢀ5% (2.5 to ꢀ25,000 cd/m2)  
0.4% (0.3 to 5 cd/m2)  
0.3% (5 to ꢀ0 cd/m2)  
Repeatability:  
Luminance (2 σ )  
0.ꢀ5% (ꢀ0 to 500,000 cd/m2)  
0.002 (0.003 to 0.005 cd/m2)  
0.00ꢀ (0.005 to 0.ꢀ cd/m2)  
0.0006 (0.ꢀ to 0.2 cd/m2)  
0.0004 (0.2 to 5,000 cd/m2)  
0.002 (0.075 to 0.ꢀ25 cd/m2)  
0.00ꢀ (0.ꢀ25 to 2.5 cd/m2)  
0.0006 (2.5 to 5 cd/m2)  
0.002 (0.3 to 0.5 cd/m2)  
0.00ꢀ (0.5 to ꢀ0 cd/m2)  
0.0006 (ꢀ0 to 20 cd/m2)  
0.0004 (20 to 500,000 cd/m2)  
Repeatability:  
Chromaticity (2 σ)  
0.0004 (5 to ꢀ25,000 cd/m2)  
Polarization error  
Integration time  
Measurement time  
Color space mode  
Interface  
ꢀ°: 2% or less (400 to 780 nm); 0.ꢀ° and 0.2°: 3% or less (400 to 780 nm)  
Fast: 0.005 to ꢀ6 sec.; Normal: 0.005 to ꢀ20 sec.  
2 sec. min. (Manual mode) to 243 sec. max. (Normal mode)  
Lv x y, Lvu'v', LvT uv, XYZ, dominant wavelength, spectral graph  
USB ꢀ.ꢀ  
Operating temperature/  
humidity range  
5 to 35°C, relative humidity 80% or less with no condensation  
0 to 35°C, relative humidity 80% or less with no condensation  
Storage temperature/  
humidity range  
Size  
Main unit: ꢀ58 (W) × 200 (H) x 300 (D) mm; Lens: ø70 x 95 mm  
6.2 kg  
Weight  
*ꢀ: Average of ꢀ0 measurements in Normal mode at a temperature  
of 23 2°C and a relative humidity of 65% or less.  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model  
CS-2000A  
380 to 780 nm  
0.9 nm/pixel  
Wavelength range  
Wavelength resolution  
Display wavelength  
bandwidth  
ꢀ.0 nm  
Wavelength precision  
Spectral bandwidth  
0.3 nm (median wavelength: 435.8 nm, 546.ꢀ nm, 643.8 nm Hg-Cd lamp)  
5 nm or less (half bandwidth)  
Measuring angle (selectable)  
ꢀ°  
0.2°  
0.ꢀ°  
Measurement luminance range  
(Standard light source A)  
0.0005 to 5,000 cd/m2  
0.0ꢀ25 to ꢀ25,000 cd/m2  
0.05 to 500,000 cd/m2  
ø5 mm  
øꢀ mm  
ø0.5 mm  
ø0.ꢀ mm when using closeup lens)  
Minimum measuring area  
(øꢀ mm when using closeup lens)  
ø0.2 mm when using closeup lens)  
Minimum measuring distance  
Minimum luminance display  
350 mm (55 mm when using closeup lens)  
0.00002 cd/m2  
Minimum spectral  
radiance display  
ꢀ.0×ꢀ0-9 W/sr, m2, nm  
Accuracy: Luminance  
(Standard light source A)*ꢀ  
2%  
x,y : 0.002 (0.00ꢀ to 0.05 cd/m2)  
x,y : 0.002 (0.025 to ꢀ.25 cd/m2)  
x,y : 0.002 (0.ꢀ to 5 cd/m2)  
Accuracy: Chromaticity  
(Standard light source A)*ꢀ  
x
y
:
:
0.00ꢀ5 (0.05 cd/m2 or more)  
0.00ꢀ (0.05 cd/m2 or more)  
x
y
:
:
0.00ꢀ5 (ꢀ.25 cd/m2 or more)  
0.00ꢀ (ꢀ.25 cd/m2 or more)  
x
y
:
:
0.00ꢀ5 (5 cd/m2 or more)  
0.00ꢀ (5 cd/m2 or more)  
ꢀ.5 % (0.0005 to 0.00ꢀ cd/m2)  
0.7 % (0.00ꢀ to 0.003 cd/m2)  
0.25 % (0.003 to 0.05 cd/m2  
0.ꢀ5 % (0.05 to 5,000 cd/m2)  
ꢀ.5 % (0.0ꢀ25 to 0.025 cd/m2)  
0.7 % (0.025 to 0.075 cd/m2  
0.25 % (0.075 to ꢀ.25 cd/m2)  
0.ꢀ5 % (ꢀ.25 to ꢀ25,000 cd/m2)  
ꢀ.5 % (0.05 to 0.ꢀ cd/m2  
)
Repeatability:  
Luminance (2 σ )  
0.7 % (0.ꢀ to 0.3 cd/m2  
0.25 % (0.3 to 5 cd/m2  
)
0.ꢀ5 % (5 to 500,000 cd/m2  
)
x : 0.003 y : 0.0035  
(0.00ꢀ to 0.003 cd/m2)  
x : 0.00ꢀ y : 0.00ꢀ5  
(0.003 to 0.ꢀ cd/m2)  
x, y : 0.0006  
x : 0.003 y : 0.0035  
(0.025 to 0.075 cd/m2)  
x : 0.00ꢀ y : 0.00ꢀ5  
(0.075 to 2.5 cd/m2)  
x, y : 0.0006  
x : 0.003 y : 0.0035  
(0.ꢀ to 0.3 cd/m2)  
x : 0.00ꢀ y : 0.00ꢀ5  
(0.3 to ꢀ0 cd/m2)  
x, y : 0.0006  
Repeatability:  
Chromaticity (2 σ)  
(0.ꢀ to 0.2 cd/m2)  
x, y : 0.0004  
(2.5 to 5 cd/m2)  
(ꢀ0 to 20 cd/m2)  
x, y : 0.0004  
x, y : 0.0004  
(5 to ꢀ25,000 cd/m2)  
(0.2 to 5,000 cd/m2)  
(20 to 500,000 cd/m2)  
Polarization error  
Integration time  
Measurement time  
Color space mode  
Interface  
ꢀ°: 2% or less (400 to 780 nm); 0.ꢀ° and 0.2°: 3% or less (400 to 780 nm)  
Fast: 0.005 to ꢀ6 sec.; Normal: 0.005 to ꢀ20 sec.  
Approx. 247 sec. max.  
Lv x y, Lvu'v', LvTuv, XYZ, dominant wavelength, spectral graph  
USB ꢀ.ꢀ  
Operating temperature/  
humidity range  
5 to 30°C, relative humidity 80% or less with no condensation  
0 to 35°C, relative humidity 80% or less with no condensation  
Storage temperature/  
humidity range  
Size  
Main unit: ꢀ58 (W) × 200 (H) x 300 (D) mm; Lens: ø70 x 95 mm  
6.2 kg  
Weight  
*ꢀ: Average of ꢀ0 measurements in Normal mode at a temperature  
of 23 2°C and a relative humidity of 65% or less.  
88  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9222-A0E3-13  
©2007-2012 KONICA MINOLTA OPTICS, INC.  
BCEEEE Printed in Japan  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia Flat Panel Television NS LCD37HD 09 User Manual
Jackson Cooktop J051E User Manual
JVC Car Speaker CS HX645 User Manual
JVC Home Theater System NX BD3 User Manual
Kawasaki Automobile Parts JS800A3 User Manual
Kenmore Refrigerator 25344723101 User Manual
Kenwood Automobile Accessories KPA H2EC User Manual
Kompernass Blender KH498 03 User Manual
Konica Minolta Printer 1690MF User Manual
Korg Electronic Keyboard KORG Pa50 User Manual