| Micathermic   Heater   Instruction Booklet   KMH100   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   1 14/09/11 1:58 PM   Contents   Kambrook Recommends   Safety First   p4   p6   Your Kambrook   Micathermic Heater   Quick Start Guide   p7   p8   Using Your   Micathermic Heater   Care, Cleaning and Storage   p13   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   3 14/09/11 1:58 PM   Kambrook Recommends Safety First   IMPORTANT: Please retain your   instruction book for future use.   At Kambrook, we believe that safe performance is the first priority in any   consumer product, so that you, our valued customer can confidently   use and trust our products. We ask that any electrical appliance that   you use be operated in a sensible fashion with due care and attention   placed on the following important operating instructions.   Important Safeguards For Your Kambrook   Micathermic Heater   • Carefully read all instructions before   operating the Heater and save for   future reference.   • Do not operate any heater with a damaged   cord or plug,or if the heater has been dropped   or damaged in any manner.Return the heater   to your nearest Kambrook Service Centre   for examination,electrical or mechanical   adjustment or repair.   • Remove any packaging material and   promotional stickers before using the Heater   for the first time.   • Do not use outdoors.This heater is not   intended for commercial use, such as   construction sites.   • Connect only to a 230V or 240V   power point.   • Avoid touching the heater body while it is on,   as some parts of the heater are hot.When   moving the unit switch off and hold the heater   by the handles where provided.   • Do not locate the heater immediately below   and in front of a socket outlet when in use.   • Do not use this heater with an external   programmer, timer or any other device that   switches the heater on automatically. Since   a fire risk may exist if the heater is covered or   positioned incorrectly.   WARNING: In order to   avoid overheating, do   not cover the heater.   • This heater is not intended for use in wet or   moist locations. Do not immerse or allow liquids   to be spilt on the heater.   • Do not use this heater in the immediate   surroundings of a bath, a shower or a   swimming pool.   • Extreme caution and supervision is necessary   when this heater is used by or near children or   invalids.   • This heater has hot and arcing or sparking   parts inside. Do not use in areas where   petrol, paints, aerosols, or other inflammable   substances are used or stored.   • Extreme caution and supervision is necessary   when this heater is used near animals.   • Do not mount on ceiling.   • Do not leave the heater unattended.Always   switch off the heater at the controls and at   the power outlet then unplug from the power   outlet when not in use.   • Do not operate the heater with the power cord   damaged,frayed or split,wound around any   part of the heater,or in contact with heated   surfaces of the heater.   • Do not use heater to dry your laundry.   • Do not operate heater whilst asleep.   4 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   4 14/09/11 1:58 PM   • Do not allow materials that have been in   contact with oil, petroleum based products   or drying fluids to come in contact with the   heater.   • Use this heater only as described in this   instruction manual.Any other use not   recommended by the manufacturer may   cause fire electric shock or injury and voids all   warranties.   • Do not run the cord under carpeting or cover   the cord with rugs, runners or the like.Arrange   the cord away from traffic areas and where it   will not be tripped over.   • Keep combustible materials such as drapes   and other furnishings at least 2.0 metres from   the front and 0.5m from the sides and rear   (when it is intended for floor use) and 1.0m   from the top of the heater.   • To disconnect the heater, switch control to off,   turn off at the power outlet then remove the   plug from the outlet.   • To prevent a possible fire or heat damage,   allow ample space around the heater (at   least 2.0m at front, 1.0m at the top and 0.5m at   the rear and sides when it is intended for floor   use), (at least 2.0m at the front, 1.0m at the top   and 0.5m at the sides when it is wall mounted)   and do not totally or partially block the air inlet   or outlets in any manner. Check the openings   from time to time for accumulated dust.   • Do not insert or allow foreign objects to pass   through the inlet or outlet openings.This may   cause an electric shock, fire or damage the   heater.   • Do not touch hot surfaces.   • Switch off at the control switch and power   outlet, then unplug and allow the heater to   cool down before cleaning or storing.   Important Safeguards For All   Electrical Appliances   • Carefully read all instructions before operating   the appliance and save for future reference.   • This appliance is for household use only. Do not   use this appliance for other than its intended   use. Do not use in moving vehicles or boats.   Do not use outdoors. Misuse may cause injury.   • Remove and safely discard all packaging   material and promotional labels before using   the appliance for the first time.   • The installation of a residual current device   (safety switch) is recommended to provide   additional safety protection when using   electrical appliances. It is advisable that a   safety switch with a rated residual operating   current not exceeding 30mA be installed in   the electrical circuit supplying the appliance.   See your electrician for professional advice   • Fully unwind the power cord before use.   • Do not let the power cord hang over the edge   of a bench or table, touch hot surfaces or   become knotted.   • To protect against electric shock, do not   immerse the power cord, power plug or   appliance in water or any other liquid, unless it   is recommended in the cleaning instructions.   • Always turn the appliance to the OFF   position, switch off at the power outlet   and unplug at the power outlet when the   appliance is not in use.   • The appliance is not intended for use by   persons (including children) with reduced   physical, sensory or mental capabilities, or lack   of experience and knowledge, unless they   have been given supervision or instruction   concerning use of the appliance, by a person   responsible for their safety.   • Before cleaning, always turn the appliance to   the OFF position, switch off at the power outlet,   unplug at the power outlet and remove the   power cord, if detachable, from the appliance   and allow all parts to cool.   • Children should be supervised to ensure that   they do not play with the appliance.   • Do not place this appliance on or near a heat   source, such as hot plate, oven or heaters.   • It is recommended to inspect the appliance   regularly. Do not use the appliance if the   power supply cord, plug, connector or   appliance becomes damaged in anyway.   Return the entire appliance to the nearest   authorised Kambrook Service Centre for   examination and/or repair.   • Position the appliance at a minimum   distance of 20cm away from walls, curtains   and other heat or steam sensitive materials   and provide adequate space above and on   all sides for air circulation.   • Any maintenance other than cleaning should   be performed at an authorised Kambrook   Service Centre.   5 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   5 14/09/11 1:58 PM   Your Kambrook Micathermic Heater   1. 1500 watts of power for fast and   5. Wheels for easy movement   6. Carry handle   even heat   2. Heat setting dial for OFF, LOW   NOT SHOWN   or HI   • • • Wall mountable bracket   Safety tip-over switch   ThermoGuard safety protection   for peace of mind   3. Variable THERMOSTAT   control to maintain your   desired temperature   4. Micathermic element   produces both radiant and   convection heat   6 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   6 14/09/11 1:58 PM   Quick Start Guide   Turning the   heater on after   assembly   Setting the   variable   temperature   Setting the   heating mode   Turn the heat   Plug the cord into   Turn the heat   Turn the variable   THERMOSTAT dial in   an anti-clockwise   position to the   setting dial to the   off position. Make   sure that the switch   on the THERMOSTAT   dial is set to MIN.   a 230V or 240V   power point and   switch on.   setting dial in a   clockwise position   to the LOW or HI   heat setting.   MAX setting.   Turning the   heater off   When a   Return the heat   setting dial to the   OFF position to turn   off the heater.   comfortable room   temperature has   been reached,   turn the variable   THERMOSTAT in   an anti-clockwise   direction until a   click sound is heard,   then stop.   • Fit window coverings like curtains to limit   winter heat loss   • Put draft stoppers, such as a rolled   up towel, at the bottom of outside   doorways to keep out cold air   • Keep the heat in and the   cold out by installing wall and ceiling   insulation   • Avoid placing items too close to the   heater at the front (and back if it is for   floor use) for optimal air flow   Hints/Tips to Retain Heat in   Your Home   • Don’t overheat your home.The   temperature of a heated room in winter   should be 18-21°C   • Your heater will work more efficiently if   you stick to Kambrook’s recommended   clearance spaces   • Choose the right size heater for the room   type you want to heat   • Zone off unoccupied rooms by closing   doors and only heat the main living areas   7 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   7 14/09/11 1:58 PM   Using Your Micathermic Heater   2. Line up the screw in the wheels   Before First Use   Remove any promotional material or   packaging from the heater.   with those in the base of the   brackets, and secure.   When unpacking the heater, check   to see you have received the wheels   and wall mounting packs, before   discarding the packaging.   Unwind the cord to its full length and   place the heater on a firm,level   surface in a stable upright position.   Visually inspect the air inlet and outlets   to ensure there are no blockages.   Fig. 3   Securing The Heater Wheels   The heater has four wheels and two   wheel brackets that come with a   set of screws.The wheel screws are   located in the wheel pack.   3. Turn the heater upside down.   Place the plastic wheel brackets   onto the two perforations, located   at the base of the heater. Ensure   the bracket with the centre hole   (near the centre screw) is placed   on the right hand side of the   heater.   Fig. 1   1. Insert the screw into the wheel,   ensuring the flat end of the screw   sits between the wheels.   Fig. 4   Fig. 2   8 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   8 14/09/11 1:58 PM   4. Line up the bracket screw with   the screw hole in the base of the   heater, and secure.   CAUTION: Before   mounting the heater to   the wall, please ensure   that both attachment   points are secure in either   timber or concrete. Do   NOT secure directly into   plaster. Please contact   a tradesman if you are   unsure. Please see Fig.   7. which illustrates the   points of contact. Ensure   that the heater is at least   0.5 metres from the floor   and corners of the wall.   Fig. 5   NOTE: Ensure the feet are   removed from the unit before   wall mounting the heater.   NOTE: The heater comes with   two sets of screws and wall   mounting brackets which can   be found in the bracket pack   and on the back of the heater.   Fig. 6   5. Turn the heater upright so that   the wheels are holding up the   heating unit.   1. Locate the brackets at the back   of the heater.The bracket is   located at the top of the heater   in the centre as per fig 7.   Wall Mounting Instructions   Please ensure your wall is capable   of holding the weight of this heater   and that the right screws are used for   your wall.   This unit can be mounted on any wall   in most rooms of the home (except in   the immediate surroundings of a bath,   a shower or a swimming pool).When   selecting a location, decide upon a   position that takes advantage of the   maximum volume of air flow.   Fig. 7   9 Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   9 14/09/11 1:58 PM   Using Your Micathermic Heater   continued   2. As a general safety guide select   a suitable location to wall mount   the heater, approximately 0.5m   from any furniture/furnishing either   side of the unit and 2m from any   furniture/furnishing placed in front   of the heater.The heater must be   mounted horizontally as per Fig 8.   6. Once the heater is mounted   on the wall, lodge the heater   to the mounting bracket to   prevent the heater from being   accidently dislodged from the   mounting bracket.   7. Visually inspect the front panel   to ensure no foreign material is   blocking this area.   CAUTION: Do not   mount the heater below   curtains and/or other   flammable items.   Turning Your Heater On   Fig. 8   Turn the heat setting dial to the OFF   position. Make sure that the switch on   the THERMOSTAT dial is set to MIN.   3. When selecting a location, make   sure the base of the heater is at   least 0.5m from the floor and at   least 1.0m from the ceiling.   Plug the cord into a 230V or 240V   power point and switch on.   4. Measure out and mark the screw   locations. Once you are confident   that the screw locations are   NOTE: To avoid an electrical   circuit overload, it is   recommended that no other   appliances are plugged into   the same circuit as your heater,   when it is in use.   correct, drill suitable size holes.   5. Take care with inserting the screws   into the holes you have made,   and then mount the heater onto   the wall bracket.   10   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 10   14/09/11 1:58 PM   Setting The Heating Mode   Setting The Variable   Thermostat   The variable THERMOSTAT can be used   to maintain your desired temperature.   Turn the variable THERMOSTAT dial to   the MAX setting. Once a comfortable   room temperature has been reached,   slowly turn the variable THERMOSTAT   dial anti-clockwise until a click sound   is heard.   Fig. 9   At this setting your heater will   automatically cycle on and off   to maintain the desired room   temperature.   To activate the heater, turn the heat   setting dial clockwise to the LOW or HI   setting.The heater will start operating   on the selected heat setting and   the red power indicator light will   illuminate. Use the heat setting dial to   select the desired heat setting.   LOW – Low heat setting (1000 watts)   HI – High heat setting (1500 watts)   Turn the heat setting dial to the OFF   position to stop the heater operating.   Fig. 10   To adjust the set temperature turn the   variable THERMOSTAT dial clockwise   to increase the desired temperature   and anti-clockwise to decrease the   desired temperature.   NOTE: This heater features a   tip-over switch. If the heater tips   over, it will automatically switch   off. Once placed back into the   upright position, the heater will   resume operation.   NOTE: You may notice a faint   smell and light crackle sound   when using the mica heater for   the first time. This is normal and   nothing to worry about. Continue   running the mica heater, the   smell will dissipates.   11   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 11   14/09/11 1:58 PM   Using Your Micathermic Heater   continued   ThermoGuard Overheating   Safety Device   Your heater is fitted with a safety   device that switches off the heater   in the event of overheating. Should   this heater stop working, turn off the   heater and inspect the air inlet and   outlet for blockages. Wait at least   five minutes for the protection system   to reset before attempting to restart   the heater.   If the heater fails to operate or the   safety device switches off again,   return the heater to your nearest   Kambrook service centre for   examination or repair.   12   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 12   14/09/11 1:58 PM   Care, Cleaning and Storage   Ensure that the heater is switched off   and disconnected from the power   point before cleaning.   Use a clean, dry cloth to clean the   external surfaces of the heater. If   the heater has collected dust or dirt   inside the unit, have the unit cleaned   by a qualified service agent. Do not   operate the heater in this condition.   Do not attempt to open up any   parts of the heater as there are no   customer serviceable parts inside.   When not in use, store the heater   (preferably in its original box) in a   cool, clean and dry location.   13   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 13   14/09/11 1:58 PM   Notes   14   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 14   14/09/11 1:58 PM   Notes   15   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd 15   14/09/11 1:58 PM   Kambrook - Australia   Kambrook - New Zealand   Building 2, Port Air Industrial Estate   1A Hale Street   Private Bag 94411   Botany, Manukau   Botany NSW 2019   Auckland 2163   Australia   New Zealand   Customer Service Line 1300 139 798   Customer Service Fax 1800 621 337   Customer Service Line/   Spare Parts 0800 273 845   Customer Service Fax 0800 288 513   Due to continual improvement in design or otherwise, the product you   purchase may differ slightly from the illustration in this book. Issue A11   Download from Www.Somanuals.com. All Manuals Search And Download.   KMH100_IB_A11_FA.indd   1 14/09/11 1:58 PM   |