I6 Infortrend 5251F6
15-bay Rackmount & Tower Enclosures
Installation Guide
October 22, 2003
•
Revision A
Patent Pending
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of
Contents
Rackmount Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Tower Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Fibre Channel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
ID Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Thermal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Fault Indication Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
S-FLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
S-ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Canister Removal/Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Drive Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
Slot Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Front Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
External I/O Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
iii
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Blower Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2
Spare Hardware Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
Rail Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1
Manual Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-1
Drive Manufacturers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
iv
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
The 15-bay FORTRA I6 Infortrend 5251F6 enclosures are designed to be used
with a host system to provide a high-end RAID subsystem. The following is a
summary of the 15-bay Rackmount and Tower enclosure features:
•
The 15-bay FORTRA I6 Infortrend 5251F6 Tower enclosure supports
up to fifteen LP SCA 40-pin SCA drives. This model supports up to six
2Gb/s Fibre Channel loops. The Fibre Channel enclosure has dual or
quad fibre channel host ports and dual or quad fibre channel drive ports.
•
The 15-bay FORTRA I6 Infortrend 5251F6 Rackmount is a 19" wide,
3U (5-1/4") high rackmount enclosure that supports up to fifteen LP SCA
40-pin drives. All other features are the same as the 15-bay FORTRA
Tower.
2/4/6/8/10/12/15-bay Product Family Features
StorBlade
FORTRA and
are families of high-end enclosures designed for
high-volume performance storage solutions. The following table shows the
StorBlade
features of the FORTRA 2/4/6/8/10/12/15-bay and
products:
4-bay1,3 6-bay*1,3 8-bay1 10-bay*1,2
15-bay*1,3
2-bay
12-bay
StorBlade
Number of Device Bays
2
1
4
1
6
1 or 2
1 or 2
2
8
10
2
12
2
15
2
4
Number of Blowers
2
2
Number of Power Supplies
Number of I/O Channels (SCSI Only)
SCSI SE/LVD Supported
Fibre Channel Supported
Hot-Swap Canisters
1
1
2
2
2
2
1 or 2
1
1
2
2
2
2
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Removable Power Supplies
Removable Blowers
Fibre only
Fibre only
Fibre only
P
P
P
N+1 Power Supplies
P
N+1 Blowers
P
MIA Support (FC Only)
P
P
P
P
Loop Expansion Support (FC Only)
Daisy Chainable (SCSI Only)
Built-in Termination (SCSI Only)
Auto Termination (SCSI Only)
SAF-TE/SES Ready (Optional)
SAF-TE/SES Compatible
SCSI to SCSI RAID Support
Fibre to SCSI RAID Support
Fibre to Fibre RAID Support
Fibre to ATA RAID Support
SCSI to ATA RAID Support
(D)esktop/(T)ower/(R)ackmount
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Fibre only
Fibre only
P
P
P
P
P
P
R
D
D
DTR
T
TR
TR
R
* 6/10/15-bay unit features apply to both Tower and Rackmount models
1 Features are based on a standard configuration with no internal host controller(s) installed
2 Fibre channel 10/15-bay enclosures have built-in SES
3 Fibre Channel 2Gb Model available. 2Gb models use SFP transceivers.
1-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
FORTRA products use advanced mid-plane technology developed by JMR,
which allows power supplies, drives, and all other enclosure components to
interface into a single board. This provides superior performance and easy
connectivity.
The host interface supports SFP Fibre Channel connections at 2Gb/s.
All 15-bay FORTRA 2Gb/s Fibre enclosures have built-in SES on the
personality card that allows control and monitoring of some enclosure
components.
Rackmount Specifications
Dimensions/Weight
Unit Weight
Height
Width
40 lbs. (18.2kg)
5-1/4" (3U) (133mm)
19" (483mm)
Depth
23" (584mm)
Power Supply (Each power supply includes internal cooling fan)
Quantity:
Power:
Input:
2
430 Watts each (N+1) Power Factor Correction
100-260 VAC; 50-60Hz
+5V @ 35A
Output:
+12V @ 30A
Blower
Quantity:
Size:
Air Flow:
Noise:
4 (2 per cannister)
97mm (3.82") each
25.42CFM (0.72m3/min) each
52dB(A)
Tower Specifications
Dimensions/Weight
Unit Weight
Height
Width
43 lbs. (19.5kg)
20-1/2" (521mm)
9-5/8" (235mm)
24" (610mm)
Depth
Power Supply (Each power supply includes internal cooling fan)
Quantity:
Power:
Input:
2
430 Watts each (N+1) Power Factor Correction
100-260 VAC; 50-60Hz
+5V @ 35A
Output:
+12V @ 30A
1-2
FORTRA 15-bay I4 Infortrend 5251F44 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Blower
Quantity:
Size:
Air Flow:
Noise:
4 (2 per cannister)
97mm (3.82") each
25.42CFM (0.72m3/min) each
52dB(A)
Fibre Channel Features
Loop Expansion
FORTRA 15-bay 2Gb/s Fibre Channel JBOD enclosures include a loop
expansion I/O connector on each fibre channel drive port. This allows the
connection to other Fibre Channel JBOD enclosures.
Loop Bypass and Clock Timing Circuit
Each port includes a loop bypass circuit that monitors each slot for a loop
connection. It has two modes of operation: NORMAL and BYPASS. In
NORMAL mode, the device is connected to the loop. In BYPASS mode, the
device is either absent or non-functional and data bypasses to the next available
device until the correct device is located.
The unit also has a built-in clock recovery circuit that adjusts the timing for any
input or output that is going through the enclosure.
SFP Connector
The 15-bay 2Gb/s Fibre Channel enclosures use Small Formfactor Plug (SFP) as
the Fibre I/O ports.
Dual Loops
A single loop is required for unit operation, however both loops can be used to
connect to different hosts, dual host adapters, and other devices, for flexible and
even redundant configurations. For specific connection and installation
ID Selection
0-124 device ID addresses are addressable and can be easily set-up via ID rotary
switches located on the personality modules. For specific connection and
SES
The 15-bay Fibre Channel enclosures have a built-in SES processor on the
1-3
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Hardware Specification
This chapter covers specification information for all FORTRA enclosures. The
following matrix describes the available configurations for FORTRA and
StorBladeTM
enclosures.
FR XX X L 2 1 X 2 X XX X X
SINGLE/DUAL CONTROLLER
S = Single Controller
D = Dual Controller
BACKPLANE TYPE
- = 1 Gigabit Backplane
2 = 2 Gigabit Backplane
CONTROLLER MANUFACTURER/MODEL#/INTERFACE
-
=
None (Blank if at the end of P/N)
H1 = Chaparral G5312/ LVD Host/ LVD Drives
H2 = Chaparral G7313/ 1G Fibre Host/ LVD Drives
H3 = Chaparral K5312/ LVD Host/ LVD Drives
H4 = Chaparral K7313/ 1G Fibre Host/ LVD Drives
H5 = Chaparral JSS122/ LVD Host/ LVD Drives
H6 = Chaparral JFS124/ 1G Fibre Host/ LVD Drives
H8 = Chaparral JFS224/ 2G Fibre Host/ LVD Drives
FZ = Microtest FileZerver Network Attached/Ethernet/ LVD Drives
ES = Infortrend 7250F-U3 SCSI Host/ ATA Drives w/ethernet
EF = Infortrend 7250F-F2 Fibre Host/ ATA Drives w/ethernet
I 2 = Infortrend Sentinel 3250-50/ LVD Host/ LVD Drives
Infortrend Sentinel 3250-50 w/IFT9282F/ 1G Fibre Host/ LVD Drives
I 3 = Infortrend EonRAID 5200-50 w/IFT9288B6B/ 1G Fibre Host/ 1G Fibre Drives
I 4 = Infortrend EonRAID 5251F4/ 2G Fibre Host/ 2G Fibre Drives
I 5 = Infortrend SentinelRAID 3252/ LVD Host/ LVD Drives
I 6 = Infortrend EonRAID 5251F6/ 2G Fibre Host/ 2G Fibre Drives
I S = JMR 7250-U3/ SCSI Host/ ATA Drives
I F = JMR 7250-F2/ 2G Fibre Host/ ATA Drives
M 3= Mylex DAC-FFx/ 1G Fibre Host/1G Fibre Drives
M 5= Mylex DAC-FFx2+Ethernet/ 2G Fibre Host/ 2G Fibre Drives w/ethernet
SAF-TE/SES
-
=
None (Blank if at the end of P/N)
S = SAF-TE/SES
POWER SUPPLY QUANTITY
# = A number Equal to Power Supplies in Enclosure
AC or DC POWER SUPPLY
-
D
=
=
AC Power Supply
DC Power Supply
COLOR - CANISTER/ACCENT
1 = Silver/Opal
2 = Black/Black
3 = Silver/Black
4 = Blue/Blue
DRIVE I/O SCSI CHANNELS or FIBRE LOOPS
# = A Number Equal to Drive I/O Channels
ENCLOSURE I/O
L = SCSI 3 Ultra 160 (LVD/SE Multimode, Fast-Wide, HD68)
F = 1 or 2Gb/s Fibre Channel
A = ATA
FIBRE GBIC READY
- = No GBIC Slots
G = GBIC Ready
u.s. Power cords Included
For International Models
NUMBER OF DRIVES
# = Drives (02,04,06,08,10,12,15)
Add Power Cord:
Australia = CBL-00602
Europe = CBL- 00525
FAMILY SERIES
FR = Fortra Rackmount
FT = Fortra Tower
UK
= CBL-00677
1U = StorBlade Rackmount
2-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Environmental Specifications
Operating Temperature: 5°C to 40°C (41°F to 104°F)
Storage Temperature:
0°C to 65°C (32°F to 149°F)
The maximum recommended ambient temperature depends on the
recommendation of the manufacturer for the devices being installed.
Electrical Specifications
AC Inlet Type: IEC320/EN60320
Power Cord: NEMA5-15P
Power Supply: Auto-switching for 110/220V operation
Agency Compliance
FORTRA enclosures have been designed and built to comply with the FCC,
UL, CSA/TUV, CE, and C-Tick standards. For more information on FCC Class
A compliance, see page 2.
Packaging Specifications
FORTRA packaging has been designed to be reusable and recyclable. Drives
may be installed and shipped in the canisters as long as the canisters are not
installed in the enclosure. Shipping the unit with canisters and/or power supplies
installed in the enclosure may cause damage to the enclosure or to the drives and
will void the warranty.
SAFETY TIP: Reshipping the enclosure with canisters, drives, or power
supplies installed in the enclosure may cause damage to these
components and will void the warranty
SICHERHEITSHINWEIS: Der Versand des Gehäuses mit eingebauten
Einschüben, Platten und Netzteilen kann zur Beschädigung dieser
Komponenten führen und somit den Garantieanspruch gefährden.
Packaging complies with ISTA (International Safe Transit Association) standards
and has been ISTA certified.
Each canister is pre-packaged in an anti-static bag. Do not throw the packaging
away if the product is intended for re-shipping. When transporting or shipping a
JMR approved shipping container must be used.
Disclaimer
The original product packaging has been tested and is safe under normal shipping
circumstances. Reshipping the product without using the original product
packaging will void the warranty. Do not ship the unit with canisters and/or
power supplies installed in the enclosure as this will void the warranty and could
cause damage to the unit and drives. The canisters should be packaged separately
within the product packaging, as provided.
2-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermal Specifications
FORTRA enclosures have been designed to meet the air-flow/cooling
requirements for popular 7,200, 10,000 and 15,000 RPM disk drives. Using high
performance blowers, air is pulled in from all open vents and exhausted out the
back of the unit.
Rotation Vibration Specifications
FORTRA enclosures have been designed to meet the rotation vibration/shock
requirements for popular 7,200, 10,000, and 15,000 RPM disk drives.
Fault Indication Features
This section reviews the indicators that will notify the user of a power supply or
15-bay Fault Indicators
On a blower fault, all the front status LEDs will blink 'Red'. The blower LED on
the back of the unit will light red and an audible alert will sound.
On a power supply fault, all the front status LEDs will also blink 'Red'. The
power supply fault LED will light and an audible alert will sound. The audible
alert can be turned off through SES.
15-bay Audible Alert
There are three audible enclosure alerts:
Two beeps indicate a temperature issue.
Three beeps indicate a blower failure;
Five beeps indicate a power supply failure;
S-FLT
The S-FLT LED on the back of the unit indicates an error on the SES bus. It will
also blink whenever the host controller interrogates the SES processor for a status
update.
S-ACT
The S-ACT LED will blink to indicate activity on the SES bus.
2-3
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Device Installation
This chapter covers Fibre Channel device installation for 15-bay rackmount
and15-bay tower enclosures.
SCA Connection and Hot-Swapping
The unit uses SCA-2, 40-pin connectors which provide a safe means of
connection/disconnection when hot-swapping devices. In order to hot-swap
devices, the host adapter or RAID controller and host operating software must
support the feature. Any SCA drive is capable of plugging directly into the
backplane of the unit and should not require any additional cabling or
connections.
Canister Removal/Insertion
Note: The photos in this section are for illustration only and are not
intended to represent a particular size enclosure.
1. The photo to the right shows the canister in a
locked position.
2. Pull the handle out to unlock the canister from the
FORTRA unit. Ensure that the thumb is placed
below the line. Pressing the thumb against the
Status LED lens could break it. Notice that the
locking tab slides down as the handle is pulled
out.
SAFETY TIP: After disengaging a device from the enclosure, allow 10 seconds
before pulling the canister out of the unit. This allows the device to
properly spin/shut down before transport.
SICHERHEITSHINWEIS: Nachdem ein Einschub vom Gehäuse wie in "Step
3" gezeigt gelöst wurde, warten Sie bitte ca. 10 Sekunden bevor der
Einschub ganz heraus gezogen wird Dies ermöglicht den Auslauf der
Festplatte bis zum vollständigen Stillstand der rotierenden Scheiben für
einen sicheren Transport.
3. Pull the canister straight out to remove. Ensure that
any installed devices are spun down before full
removal to prevent damage to the drive.
Follow the steps in reverse to reinstall.
3-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Drive Installation
Device Mounting Holes (4)
Status Indicators
Handle
Device mounting screws are included with the unit for device mounting. The
JMR part number for the #6-32" mounting screws is HDS-01906.
WARNING: Before device installation, alleviate any electro-static discharge by
touching a grounded metal assembly. Static can be potentially damaging
to enclosure components.
WARNUNG: Berühren Sie vor der Festplatteninstallation geerdete
Metallgegenstände, um elektro statische Aufladung abzuleiten. Statische
Aufladung kann elektronische Gehäusekomponenten schwer beschädigen.
WARNING: The #6-32 mounting screws that are provided have been specially
designed to fit the canisters. Do not install the device using any other
screws than the ones provided.
WARNUNG: Die mitgelieferten Befestigungsschrauben #6-32 wurden speziell
für die Einschübe angefertigt und zur Befestigung der Festplatte sollten
Sie keinesfalls andere als diese verwenden.
1. After removing the canister, place it on a static free surface along with the
device to be installed.
2. Place the device in the canister and mount it using the provided screws
(use 4 screws to mount the drive).
3. Replace the canister into the unit by following the steps for Removal of a
Device Canister but in reverse order.
3-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Repeat steps 1 through 3 until all devices are installed, then move onto
step 5 to complete unit setup and installation.
setup.
into a cabinet.
3-3
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Fibre Channel Setup
This chapter covers Fibre Channel device configuration and option settings. All
Fibre Channel 15-bay units have built-in SES on the personality card. Refer to
before beginning setup.
WARNING: Take care when connecting the unit to an AC power source to
ensure that it is plugged-in to a circuit of the appropriate rating (110v or
220v). For safe operation, the circuit should have over-current protection
to prevent damage to the unit in the event of circuit overloading.
WARNUNG: Vergewissern Sie sich, daß die Netzspannung (220V / 110V)
korrekt eingestellt ist, bevor Sie das Gerät mit dem Stromnetz verbinden.
Zur Sicherheit sollte das Netz über einen Überspannungsschutz zur
Vermeidung von Schäden im Falle einer Überlast verfügen.
WARNING: When connecting the unit to an AC outlet or power strip, ensure
that the outlet has the proper connection for grounding. The AC power
cables included with the unit have three prongs, one of which is used for
the ground connection. Do not use a two prong AC cable with the unit
since this will not allow for proper unit grounding and could cause
problems with normal unit operation.
WARNUNG: Bei der Verbindung der Unit mit einer Steckdose oder einer
Verteilerdose sollten sie auf eine korrekte Erdung derselben achten. Die
mitgelieferten Kaltgeräteanschlußkabel habe 3 Kontakte, von denen
einer zur Erdung verwendet wird. Verwenden Sie kein Stromkabel mit 2
Anschlüssen, da dieses keine korrekte Erdung ermöglicht und Probleme
während des regulären Betriebs verursachen kann.
Slot Settings
The pictures to the right and below show the slot
numbering sequence and the default ID settings.
Slot 0, ID 0
Default ID settings are based on both ID rotary
switches set to a value of 0.
Slot 1, ID 1
Slot 2, ID 2
Slot 3, ID 3
Slot 4, ID 4
Slot 5, ID 5
Slot 6, ID 6
Slot 7, ID 7
Slot 8, ID 8
Slot 9, ID 9
Slot 10, ID 10
Slot 11, ID 11
Slot 12, ID 12
Slot 13, ID 13
Slot 14, ID 14
4-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting ID
Rotary switch settings only affect Slot 0 and all other slots are sequentially
increased by a value of one after that slot.
The ID is set sequentially starting from a base address. The base address, or
starting address, is set via a 0-7 position rotary switch located on the personality
module. There is a second 0-15 position rotary switch which can be changed to
modify the base address setting.
The default value for both switches is 0. In this default configuration, the device ID
values are as shown.
The 0-7 switch is used to set the
base address which is multiplied
by 16, and the 0-15 switch is
used to set the offset modifier to
the base address. The formula
for setting the ID is: x(16)+y,
where x is the 0-7 switch and y is
the 0-15 switch.
SW1 - ID
setting 0-15
SW2 - ID
setting 0-7
Ex. The 0-7 switch is set to 2, the 0-15 switch is set to 6. This sets the base address
to 38 (2*16=32, +6=38). So Slot 0 ID = 38, Slot 1 ID = 39, Slot 2 ID = 40, Slot 3
ID = 41, etc… up to Slot 9 ID = 47.
The table below provides the Slot 0 Starting (Base) Address Settings.
MSB
0
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
8
9
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
112
113
114
115
116
117
118
119
120
121
122
123
124
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
10 (A) 10
11 (B) 11
12 (C) 12
13 (D) 13
14 (E)
15 (F)
14
15
4-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
ID Conflict
When two devices share the same ID, a conflict occurs. This should not happen
unless two or more enclosures are daisy chained together. If devices in one
enclosure conflict with devices in another enclosure, the devices will re-arbitrate
ID and resolve the conflict.
Option Settings
Three option settings are located on the personality card. To access the jumpers,
the cover must be removed. The figure below shows the location of the option
settings on the personality card.
W1*
Delayed Start
& Remote Start
* Located on the mid-plane board.
Delayed Start Option Jumper
Header W1 pins 1 & 2.
Jumper on = enabled.
Jumper off = disabled (default).
Remote Start Option Jumper
Header W1 pins 3 & 4.
Jumper on = enabled.
Jumper off = disabled (default).
Front Status LEDs
A status indicator is located on each canister. A 'Blue' light indicates normal
drive activity. A 'Red' light indicates a device fault. If all canisters display a 'Red'
light that is blinking on and off it indicates that there is a system fault. A system
fault is either a power supply or blower failure. Check the back of the unit to
determine which fault has occurred. Refer to Chapter 5 for blower fault indicator
location and to Chapter 6 for power supply fault indicator location.
Status
A blue light on a single canister
indicates device activity or busy.
Indicators
A red light on a single canister
indicates a device fault.
4-3
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
External I/O Connection
The external I/O connections are located on both the personality card and the
contoller card. There are five SFP I/O connectors accessible from the rear of the
unit as shown in the figure below.
RS232 for Ethernet for Host/Drive Drive
Controller 0 Controller 0 CH 3
CH 5
Host/Drive
CH 4
Host
CH 1
Host
CH 0
Host/Drive
CH 5
Ethernet for
Controller 1
Drive
CH 2
RS232 for
Controller 1
Host/Drive
CH 4
Host
CH 0
Host
CH 1
Host CH-0 and CH-1 (Bottom)
Input connections for Host Loops 0 and 1. These are Standard (2Gb/s) SFP
transceiver connectors used to connect to host systems from controller 1.
Host CH-0 and CH-1 (Top)
Input connections for Host Loop 0 and 1. These are Standard (2Gb/s) SFP
transceiver connectors used to connect to host systems from the controller 0.
CH 2 (Bottom)
This is a standard (2Gb/s) SFP transceiver connector used to connect to a drive
expansion enclosure for Loop A side of drives. The 15 internal drives loop side A
are connected to this loop as well.
4-4
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
CH 3 (Top)
This is a standard (2Gb/s) SFP transceiver connector used to connect to a drive
expansion enclosure for Loop B side of drives. The 15 internal drives loop side B
are connected to this loop as well.
CH 4
This is a standard (2Gb/s) SFP transceiver connector used to connect to a host
system or drive expansion bay. Host or disk connection is firmware selectable.
CH 5
This is a standard (2Gb/s) SFP transceiver connector used to connect to a host
system or drive expansion bay. Host or disk connection is firmware selectable.
RS232 Controller 0
RS232 Serial Connection to the 5251F6 controller 0.
RS232 Controller 1
RS232 Serial Connection to the 5251F6 controller 1.
4-5
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Blower Operation
This chapter covers all operations of the blowers for 15-bay units. Refer to
Chapter 1 for blower specifications. The blower is hot swappable and can be
removed or installed while the enclosure continues to function, however, failure
to replace a non-working blower within a reasonable period of time may expose
drives to extreme heat, which could cause loss of data.
WARNING: Blowers are a system critical component. Non-operating blowers
should be replaced as soon as possible to avoid data loss or device failure.
WARNUNG: Gebläse sind für die Funktion wichtige Komponenten. Nicht
funktionierende Gebläse sollten so schnell wie möglich ersetzt werden,
um Datenverluste oder Fehlfunktionen zu vermeiden.
The blowers are located on the back of the
unit and each have its own fault LED that
will light if the blower is non-operational.
Fault LED
Blower Removal/Insertion
The blower is designed to be easily installed and removed.
1. Unfasten the blower thumbscrew by
turning counterclockwise. A Philips
head screwdriver can be used if the
thumbscrew is too tight to turn by hand.
2. Remove the blower sled by pulling out
on the handle and grasping the side of
the blower tray. Wait for the blower to
stop completely before removing it
from the unit.
Reverse the steps to reinstall the blower.
WARNING: To prevent injury when removing or installing the blower, do not
grab the bottom of the tray which is used for blower access intake. The
blower operates at high speeds and continues to spin for a short time
after power is disconnected.
WARNUNG: Um Verletzungen während der Entfernung oder Installation des
Gebläses zu vermeiden, berühren Sie nicht dessen Unterseite, da hier
der Lufteintritt erfolgt. Das Gebläse arbeitet mit hohen
Geschwindigkeiten und läuft nach Abschalten der Versorgungsspannung
noch einige Zeit nach.
5-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: Avoid direct contact with the blower intake access hole while the
blower is running. The blower operates at high speeds and can cause
injury.
User’s removing or installing a blower must be awarre
of the blower access hole. Contact with the access hole
must be avoided while the blower is running to
prevent injury.
Blower Replacement
If the blower has stopped running or the fault LED indicator is lit, the blower may
need to be replaced. Before replacing, the cable connection should be checked to
ensure that the connector is firmly seated and that there is nothing blocking the
blower blades that could cause interference.
If you believe a blower is in a nonfunctional state, please contact the place of
purchase for repair or replacement.
The JMR part number for a replacement blower is shownbelow. The assembly
includes the tray along with the blower.
Model
JMR Part Number
15-bay
SBA-05207
5-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Power Supply Operation
This chapter covers all operations of the power supplies. For operation, the AC
cord (included) must be connected to the AC Inlet on each supply, and the power
supply must be switched ON. The 'OK LED' will light to indicate the power
supply is functioning properly. If the power supply experiences a problem and
cannot operate within its normal specifications, the Fault LED will light and the
power supply will shut itself off.
The power supplies also have their own fan included to maintain proper cooling
within each supply and also provide some additional, but minimal airflow through
the rest of the enclosure.
Thumbscrew
Handle
On/Off Switch
Fault LED
AC Inlet
OK LED
Power Supply Removal/Insertion
Follow the following steps to either remove a power supply in a 15-bay unit.
1. Unfasten the power supply thumbscrew by
turning counterclockwise. A Philips head
screwdriver may be used if the thumbscrew is
too tight to turn by hand.
2. Remove by pulling out on the handle.
Reverse the steps to reinstall the power supply.
6-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Low Power Mode (Standby Power)
When both power supplies are turned off, the unit will switch to low power or
standby mode and the power supply fans will continue to run. The unit blowers
will remain operational if a single power supply is turned off, not installed, or
fails, in order to maintain the proper low temperature within the unit. To stop the
power supply fans and turn the unit off completely, it must be disconnected from
the AC power source.
Power Supply Replacement
If the Power Supply Fault LED indicator is lit, the power supply may need to be
replaced. Before replacing, the power supply should be turned off, removed from
the enclosure, and reinstalled. The AC cable connection should be checked to
ensure that the connector is firmly seated and the power supply should be firmly
inserted with the thumbscrew tightly securing it. If the Fault LED indicator is still
coming on, then the power supply should be replaced.
If the fan in the power supply is not functioning but the power supply still works,
the power supply unit should be replaced as soon as possible. Leaving the power
supply running without the fan could cause the power supply to overheat and
shutdown at any time.
If you believe a power supply is in a nonfunctional state, please contact the place
of purchase for repair or replacement.
JMR part number for a replacement power supply is shown below. The assembly
includes the power supply installed in the canister.
Model
JMR Part Number
15-bay
PSS-00766
SAFETY TIP: Both power supplies should be installed into the unit at all times
to maintain proper cooling and airflow within the enclosure. In the event
of a power supply failure, the faulty supply should be left in the enclosure
until a replacement power supply is available.
6-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
7. FR15 Cabinet Installation
This chapter covers the installation of the Rackmount enclosure into a standard
19" (483mm) wide and 30" (762mm) to 36" (914mm) deep cabinet that meets the
EMA/RETMA standards.
Before beginning rail installation, please take note of the following precautions:
NOTE: When installing the unit into a cabinet or closed environment, the
operating ambient temperature of the rack environment may be greater
than the maximum recommended ambient temperature. Consideration
must be taken to meet the maximum recommended ambient temperature
(Tmra) for the best unit operation.
HINWEIS: Wenn das Gerät in einen Gehäuseschrank oder eine sonstige
geschlossene Umgebung verbaut wird, kann die Umgebungstemperatur
über die maximal zulässige Betriebstemperatur ansteigen. Maßnahmen
bzgl. der maximalen, empfohlenen Betriebstemperatur (Tmra) müssen
getroffen werden, um eine bestmögliche Funktion des Gerätes zu
gewährleisten.
WARNING: Ensure that the front and back of the unit are not blocked when
installing the unit into a cabinet or closed area. Blocking the front or
back of the unit can cause reduced air- flow that will compromise the
safe operating environment within the unit.
WARNUNG: Vergewissern Sie sich, daß das Gerät an Vorder- und Rückseite
nicht abgedeckt ist, wenn das Gerät in einem Gehäuseschrank oder
einer geschlossenen Umgebung verbaut wird. Abdeckung der Vorder-
und Rückseite kann verminderte Kühlung zur Folge haben und somit
sichere Betriebsbedingungen negativ beeinflussen.
WARNING: When loading the unit into a cabinet, ensure that a hazardous
condition is not achieved due to uneven mechanical loading. To prevent
injury, remove the power supplies and drives before loading, and re-
install them after the unit has been secured in the cabinet.
WARNUNG: Vermeiden Sie während des Einbaus des Gerätes in einen
Gehäuseschrank jegliche gefährliche Aktionen, selbst wenn diese nur
mechanischer Art sind. Um Verletzungen zu vermeiden, entfernen Sie
die Netzteile und Laufwerke vor der Montage und installieren Sie diese
erst erneut, wenn das Gerät im Gehäuseschrank gesichert
ist.Vergewissern Sie sich, daß das Gerät an Vorder- und Rückseite nicht
abgedeckt ist.
7-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Rail Mounting Kit Hardware
•
•
Ten #10-32 Screws
Four each #8-32 Screws/Washers/Nuts
Spare Hardware Parts
Check with a JMR Sales Representative for pricing and availability of spare
hardware parts.
Description
#10-32 Screw
#8-32 Screw
#8-32 Nut
JMR Part Number
HDS-01580
HDS-00350
HDN-00040
#8-32 Washer
HDW-00080
Rail Installation
A completed rail assembly without the unit uinstalled would look like this:
Two #8-32 screw
Two #10-32
assemblies
screws
Two #10-
32 screws
Cabinet/Unit
Front
1. Affix the extension brackets to the main rail using the #8-32
screw/washer/nut assemblies. Adjust to the correct length for the cabinet
depth being used.
7-2
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Extension Bracket
2. Affix the extension bracket to
the rear of the unit using two
#10-32 screws. There are 3
holes in the extension bracket
for mounting. Depending on the
hole pattern that is being used in
the cabinet, two holes should
always be available for securing
the extension bracket.
3. The fronts of the rails
have three holes. Two of
the holes (top and
bottom) are used to
secure the rail to the
cabinet. The middle
hole is used to secure the
enclosure to the rail and
cabinet. Secure the front
of each rail to the
cabinet vertical rails
using two #10-32 screws
for each rail.
7-3
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Slide the unit into the cabinet and secure it to the cabinet with a single
#10-32 screw on each side.
5. Snap the end cap over the screw on each side of the unit to finish the
installation.
7-4
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
8. SES Operation
For bus management, the FORTRA Fibre channel enclosures have a built-in
SES processor designed to meet the SFF-8067 specification. By using the SES (S-
Link) connector on the back of the unit the SES bus management can be expanded
to other FORTRA Fibre enclosures that don't have a SES processor of their own
(2/4-bay units).
In order to communicate with the SES processor, at least one device must be
present in the enclosure.
8-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Infortrend 5251F6 Installation
This model is designed to be used with up to two 5251F6 RAID bridge controllers
from Infortrend. A total of six loops are provided. The table below indicates the
possible host and disk combinations. RCC is used for inter controller
communication when two controllers are installed. RCC occurs on either a
dedicated loop or shared with a disk loop and is firmware selectable.
# of Host # of Disk
RCC
Ports
Ports
4
2
2
4
Shared with drive loop
Shared with drive loop
Up to two 5251F6 controllers may be installed into the enclosure. All of the I/O
and power connections are made at the rear of the unit. Additionally, the controller
can be removed from the rear of the unit and the power supplies and blowers may
be hot-swapped from the rear of the unit.
Installation Steps
1. Install each controller into the JMR controller canister provided and plug
into the unit.
2. Install up to 15, 3.5" hard disk drives into the device canisters using 4 screws
per device (screws have been provided - JMR P/N HDS-01906) and install
3. Plug in the two AC power cords to the AC inlet located on each power
supply in the rear of the unit. Turn the power supplies on using the on/off
switch located on each power supply.
4. Connect the RS-232 port to the unit and configure the RAID set. See
Chapter 4 for connector location and use.
5. Connect the host I/O ports to a HBA or hub/switch and connect any
Default Slot ID
9-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Product Support
For current information on this product, including updates to the manual and
technical support related issues, please contact the sales support section of our
directly at the address below.
US Corporate Headquarters
JMR Electronics, Inc.
ATTN: Technical Support Division
20400 Plummer St.
Chatsworth, CA 91311
Customer Support: (818) 739-1140
E-mail: [email protected]
Office Hours: Monday-Friday 8:00 A.M. to 5:00 P.M., Pacific Standard Time
Internet: http://www.jmr.com
Manual Changes
Revision A - Initial Release
10-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A. Drive and Controller
Manufacturers
Drive Manufacturers
Fujitsu
Internet Address: www.fcpa.com
Hitachi Global Storage Technologies
Internet Address: www.hgst.com
Maxtor
Internet Address: www.maxtor.com
Seagate Technology
Internet Address: www.seagate.com
RAID Controller Manufacturers
Adaptec, Inc.
Internet Address: www.adaptec.com
Chaparral Network Storage
Internet Address: www.chaparralnet.com
Infortrend Corporation
Internet Address: www.infortrend.com
Intel ICP VORTEX (Intelligent Computer Peripherals)
Internet Address: www.icp-vortex.com
Mylex Corporation
Internet Address: www.mylex.com
Silicon Image, CMD Storage Systems
Internet Address: www.cmd.com
Host Bus Adapter Manufacturers
Adaptec, Inc.
Internet Address: www.adaptec.com
Antares Microsystems
Internet Address: www.antares.com
Emulex Corporation
Internet Address: www.emulex.com
JNI Corporation
Internet Address: www.jni.com
QLogic Corp.
Internet Address: www.qlogic.com
A-1
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A