1. Introduction  
The 15-bay FORTRA I6 Infortrend 5251F6 enclosures are designed to be used  
with a host system to provide a high-end RAID subsystem. The following is a  
summary of the 15-bay Rackmount and Tower enclosure features:  
The 15-bay FORTRA I6 Infortrend 5251F6 Tower enclosure supports  
up to fifteen LP SCA 40-pin SCA drives. This model supports up to six  
2Gb/s Fibre Channel loops. The Fibre Channel enclosure has dual or  
quad fibre channel host ports and dual or quad fibre channel drive ports.  
The 15-bay FORTRA I6 Infortrend 5251F6 Rackmount is a 19" wide,  
3U (5-1/4") high rackmount enclosure that supports up to fifteen LP SCA  
40-pin drives. All other features are the same as the 15-bay FORTRA  
Tower.  
2/4/6/8/10/12/15-bay Product Family Features  
StorBlade  
FORTRA and  
are families of high-end enclosures designed for  
high-volume performance storage solutions. The following table shows the  
StorBlade  
features of the FORTRA 2/4/6/8/10/12/15-bay and  
products:  
4-bay1,3 6-bay*1,3 8-bay1 10-bay*1,2  
15-bay*1,3  
2-bay  
12-bay  
StorBlade  
Number of Device Bays  
2
1
4
1
6
1 or 2  
1 or 2  
2
8
10  
2
12  
2
15  
2
4
Number of Blowers  
2
2
Number of Power Supplies  
Number of I/O Channels (SCSI Only)  
SCSI SE/LVD Supported  
Fibre Channel Supported  
Hot-Swap Canisters  
1
1
2
2
2
2
1 or 2  
1
1
2
2
2
2
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Removable Power Supplies  
Removable Blowers  
Fibre only  
Fibre only  
Fibre only  
P
P
P
N+1 Power Supplies  
P
N+1 Blowers  
P
MIA Support (FC Only)  
P
P
P
P
Loop Expansion Support (FC Only)  
Daisy Chainable (SCSI Only)  
Built-in Termination (SCSI Only)  
Auto Termination (SCSI Only)  
SAF-TE/SES Ready (Optional)  
SAF-TE/SES Compatible  
SCSI to SCSI RAID Support  
Fibre to SCSI RAID Support  
Fibre to Fibre RAID Support  
Fibre to ATA RAID Support  
SCSI to ATA RAID Support  
(D)esktop/(T)ower/(R)ackmount  
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Fibre only  
Fibre only  
P
P
P
P
P
P
R
D
D
DTR  
T
TR  
TR  
R
* 6/10/15-bay unit features apply to both Tower and Rackmount models  
1 Features are based on a standard configuration with no internal host controller(s) installed  
2 Fibre channel 10/15-bay enclosures have built-in SES  
3 Fibre Channel 2Gb Model available. 2Gb models use SFP transceivers.  
1-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FORTRA products use advanced mid-plane technology developed by JMR,  
which allows power supplies, drives, and all other enclosure components to  
interface into a single board. This provides superior performance and easy  
connectivity.  
The host interface supports SFP Fibre Channel connections at 2Gb/s.  
All 15-bay FORTRA 2Gb/s Fibre enclosures have built-in SES on the  
personality card that allows control and monitoring of some enclosure  
components.  
Rackmount Specifications  
Dimensions/Weight  
Unit Weight  
Height  
Width  
40 lbs. (18.2kg)  
5-1/4" (3U) (133mm)  
19" (483mm)  
Depth  
23" (584mm)  
Power Supply (Each power supply includes internal cooling fan)  
Quantity:  
Power:  
Input:  
2
430 Watts each (N+1) Power Factor Correction  
100-260 VAC; 50-60Hz  
+5V @ 35A  
Output:  
+12V @ 30A  
Blower  
Quantity:  
Size:  
Air Flow:  
Noise:  
4 (2 per cannister)  
97mm (3.82") each  
25.42CFM (0.72m3/min) each  
52dB(A)  
Tower Specifications  
Dimensions/Weight  
Unit Weight  
Height  
Width  
43 lbs. (19.5kg)  
20-1/2" (521mm)  
9-5/8" (235mm)  
24" (610mm)  
Depth  
Power Supply (Each power supply includes internal cooling fan)  
Quantity:  
Power:  
Input:  
2
430 Watts each (N+1) Power Factor Correction  
100-260 VAC; 50-60Hz  
+5V @ 35A  
Output:  
+12V @ 30A  
1-2  
FORTRA 15-bay I4 Infortrend 5251F44 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Blower  
Quantity:  
Size:  
Air Flow:  
Noise:  
4 (2 per cannister)  
97mm (3.82") each  
25.42CFM (0.72m3/min) each  
52dB(A)  
Fibre Channel Features  
Loop Expansion  
FORTRA 15-bay 2Gb/s Fibre Channel JBOD enclosures include a loop  
expansion I/O connector on each fibre channel drive port. This allows the  
connection to other Fibre Channel JBOD enclosures.  
Loop Bypass and Clock Timing Circuit  
Each port includes a loop bypass circuit that monitors each slot for a loop  
connection. It has two modes of operation: NORMAL and BYPASS. In  
NORMAL mode, the device is connected to the loop. In BYPASS mode, the  
device is either absent or non-functional and data bypasses to the next available  
device until the correct device is located.  
The unit also has a built-in clock recovery circuit that adjusts the timing for any  
input or output that is going through the enclosure.  
SFP Connector  
The 15-bay 2Gb/s Fibre Channel enclosures use Small Formfactor Plug (SFP) as  
the Fibre I/O ports.  
Dual Loops  
A single loop is required for unit operation, however both loops can be used to  
connect to different hosts, dual host adapters, and other devices, for flexible and  
even redundant configurations. For specific connection and installation  
information, refer to Chapter 4.  
ID Selection  
0-124 device ID addresses are addressable and can be easily set-up via ID rotary  
switches located on the personality modules. For specific connection and  
installation information, refer to Chapter 4.  
SES  
The 15-bay Fibre Channel enclosures have a built-in SES processor on the  
personality card. See Chapter 8 for SES information.  
1-3  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Hardware Specification  
This chapter covers specification information for all FORTRA enclosures. The  
following matrix describes the available configurations for FORTRA and  
StorBladeTM  
enclosures.  
FR XX X L 2 1 X 2 X XX X X  
SINGLE/DUAL CONTROLLER  
S = Single Controller  
D = Dual Controller  
BACKPLANE TYPE  
- = 1 Gigabit Backplane  
2 = 2 Gigabit Backplane  
CONTROLLER MANUFACTURER/MODEL#/INTERFACE  
-
=
None (Blank if at the end of P/N)  
H1 = Chaparral G5312/ LVD Host/ LVD Drives  
H2 = Chaparral G7313/ 1G Fibre Host/ LVD Drives  
H3 = Chaparral K5312/ LVD Host/ LVD Drives  
H4 = Chaparral K7313/ 1G Fibre Host/ LVD Drives  
H5 = Chaparral JSS122/ LVD Host/ LVD Drives  
H6 = Chaparral JFS124/ 1G Fibre Host/ LVD Drives  
H8 = Chaparral JFS224/ 2G Fibre Host/ LVD Drives  
FZ = Microtest FileZerver Network Attached/Ethernet/ LVD Drives  
ES = Infortrend 7250F-U3 SCSI Host/ ATA Drives w/ethernet  
EF = Infortrend 7250F-F2 Fibre Host/ ATA Drives w/ethernet  
I 2 = Infortrend Sentinel 3250-50/ LVD Host/ LVD Drives  
Infortrend Sentinel 3250-50 w/IFT9282F/ 1G Fibre Host/ LVD Drives  
I 3 = Infortrend EonRAID 5200-50 w/IFT9288B6B/ 1G Fibre Host/ 1G Fibre Drives  
I 4 = Infortrend EonRAID 5251F4/ 2G Fibre Host/ 2G Fibre Drives  
I 5 = Infortrend SentinelRAID 3252/ LVD Host/ LVD Drives  
I 6 = Infortrend EonRAID 5251F6/ 2G Fibre Host/ 2G Fibre Drives  
I S = JMR 7250-U3/ SCSI Host/ ATA Drives  
I F = JMR 7250-F2/ 2G Fibre Host/ ATA Drives  
M 3= Mylex DAC-FFx/ 1G Fibre Host/1G Fibre Drives  
M 5= Mylex DAC-FFx2+Ethernet/ 2G Fibre Host/ 2G Fibre Drives w/ethernet  
SAF-TE/SES  
-
=
None (Blank if at the end of P/N)  
S = SAF-TE/SES  
POWER SUPPLY QUANTITY  
# = A number Equal to Power Supplies in Enclosure  
AC or DC POWER SUPPLY  
-
D
=
=
AC Power Supply  
DC Power Supply  
COLOR - CANISTER/ACCENT  
1 = Silver/Opal  
2 = Black/Black  
3 = Silver/Black  
4 = Blue/Blue  
DRIVE I/O SCSI CHANNELS or FIBRE LOOPS  
# = A Number Equal to Drive I/O Channels  
ENCLOSURE I/O  
L = SCSI 3 Ultra 160 (LVD/SE Multimode, Fast-Wide, HD68)  
F = 1 or 2Gb/s Fibre Channel  
A = ATA  
FIBRE GBIC READY  
- = No GBIC Slots  
G = GBIC Ready  
u.s. Power cords Included  
For International Models  
NUMBER OF DRIVES  
# = Drives (02,04,06,08,10,12,15)  
Add Power Cord:  
Australia = CBL-00602  
Europe = CBL- 00525  
FAMILY SERIES  
FR = Fortra Rackmount  
FT = Fortra Tower  
UK  
= CBL-00677  
1U = StorBlade Rackmount  
2-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Environmental Specifications  
Operating Temperature: 5°C to 40°C (41°F to 104°F)  
Storage Temperature:  
0°C to 65°C (32°F to 149°F)  
The maximum recommended ambient temperature depends on the  
recommendation of the manufacturer for the devices being installed.  
Electrical Specifications  
AC Inlet Type: IEC320/EN60320  
Power Cord: NEMA5-15P  
Power Supply: Auto-switching for 110/220V operation  
Agency Compliance  
FORTRA enclosures have been designed and built to comply with the FCC,  
UL, CSA/TUV, CE, and C-Tick standards. For more information on FCC Class  
A compliance, see page 2.  
Packaging Specifications  
FORTRA packaging has been designed to be reusable and recyclable. Drives  
may be installed and shipped in the canisters as long as the canisters are not  
installed in the enclosure. Shipping the unit with canisters and/or power supplies  
installed in the enclosure may cause damage to the enclosure or to the drives and  
will void the warranty.  
SAFETY TIP: Reshipping the enclosure with canisters, drives, or power  
supplies installed in the enclosure may cause damage to these  
components and will void the warranty  
SICHERHEITSHINWEIS: Der Versand des Gehäuses mit eingebauten  
Einschüben, Platten und Netzteilen kann zur Beschädigung dieser  
Komponenten führen und somit den Garantieanspruch gefährden.  
Packaging complies with ISTA (International Safe Transit Association) standards  
and has been ISTA certified.  
Each canister is pre-packaged in an anti-static bag. Do not throw the packaging  
away if the product is intended for re-shipping. When transporting or shipping a  
JMR approved shipping container must be used.  
Disclaimer  
The original product packaging has been tested and is safe under normal shipping  
circumstances. Reshipping the product without using the original product  
packaging will void the warranty. Do not ship the unit with canisters and/or  
power supplies installed in the enclosure as this will void the warranty and could  
cause damage to the unit and drives. The canisters should be packaged separately  
within the product packaging, as provided.  
2-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Thermal Specifications  
FORTRA enclosures have been designed to meet the air-flow/cooling  
requirements for popular 7,200, 10,000 and 15,000 RPM disk drives. Using high  
performance blowers, air is pulled in from all open vents and exhausted out the  
back of the unit.  
Rotation Vibration Specifications  
FORTRA enclosures have been designed to meet the rotation vibration/shock  
requirements for popular 7,200, 10,000, and 15,000 RPM disk drives.  
Fault Indication Features  
This section reviews the indicators that will notify the user of a power supply or  
blower that is in a fault state. More information is available in Chapter 5  
(blowers) and Chapter 6 (power supply).  
15-bay Fault Indicators  
On a blower fault, all the front status LEDs will blink 'Red'. The blower LED on  
the back of the unit will light red and an audible alert will sound.  
On a power supply fault, all the front status LEDs will also blink 'Red'. The  
power supply fault LED will light and an audible alert will sound. The audible  
alert can be turned off through SES.  
15-bay Audible Alert  
There are three audible enclosure alerts:  
Two beeps indicate a temperature issue.  
Three beeps indicate a blower failure;  
Five beeps indicate a power supply failure;  
S-FLT  
The S-FLT LED on the back of the unit indicates an error on the SES bus. It will  
also blink whenever the host controller interrogates the SES processor for a status  
update.  
S-ACT  
The S-ACT LED will blink to indicate activity on the SES bus.  
2-3  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Device Installation  
This chapter covers Fibre Channel device installation for 15-bay rackmount  
and15-bay tower enclosures.  
SCA Connection and Hot-Swapping  
The unit uses SCA-2, 40-pin connectors which provide a safe means of  
connection/disconnection when hot-swapping devices. In order to hot-swap  
devices, the host adapter or RAID controller and host operating software must  
support the feature. Any SCA drive is capable of plugging directly into the  
backplane of the unit and should not require any additional cabling or  
connections.  
Canister Removal/Insertion  
Note: The photos in this section are for illustration only and are not  
intended to represent a particular size enclosure.  
1. The photo to the right shows the canister in a  
locked position.  
2. Pull the handle out to unlock the canister from the  
FORTRA unit. Ensure that the thumb is placed  
below the line. Pressing the thumb against the  
Status LED lens could break it. Notice that the  
locking tab slides down as the handle is pulled  
out.  
SAFETY TIP: After disengaging a device from the enclosure, allow 10 seconds  
before pulling the canister out of the unit. This allows the device to  
properly spin/shut down before transport.  
SICHERHEITSHINWEIS: Nachdem ein Einschub vom Gehäuse wie in "Step  
3" gezeigt gelöst wurde, warten Sie bitte ca. 10 Sekunden bevor der  
Einschub ganz heraus gezogen wird Dies ermöglicht den Auslauf der  
Festplatte bis zum vollständigen Stillstand der rotierenden Scheiben für  
einen sicheren Transport.  
3. Pull the canister straight out to remove. Ensure that  
any installed devices are spun down before full  
removal to prevent damage to the drive.  
Follow the steps in reverse to reinstall.  
3-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Drive Installation  
Device Mounting Holes (4)  
Status Indicators  
Handle  
Device mounting screws are included with the unit for device mounting. The  
JMR part number for the #6-32" mounting screws is HDS-01906.  
WARNING: Before device installation, alleviate any electro-static discharge by  
touching a grounded metal assembly. Static can be potentially damaging  
to enclosure components.  
WARNUNG: Berühren Sie vor der Festplatteninstallation geerdete  
Metallgegenstände, um elektro statische Aufladung abzuleiten. Statische  
Aufladung kann elektronische Gehäusekomponenten schwer beschädigen.  
WARNING: The #6-32 mounting screws that are provided have been specially  
designed to fit the canisters. Do not install the device using any other  
screws than the ones provided.  
WARNUNG: Die mitgelieferten Befestigungsschrauben #6-32 wurden speziell  
für die Einschübe angefertigt und zur Befestigung der Festplatte sollten  
Sie keinesfalls andere als diese verwenden.  
1. After removing the canister, place it on a static free surface along with the  
device to be installed.  
2. Place the device in the canister and mount it using the provided screws  
(use 4 screws to mount the drive).  
3. Replace the canister into the unit by following the steps for Removal of a  
Device Canister but in reverse order.  
3-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Repeat steps 1 through 3 until all devices are installed, then move onto  
step 5 to complete unit setup and installation.  
5. Configure ID and other options as required. See Chapter 4 for device  
setup.  
6. For 15-bay rackmount units, refer to Chapter 7 to install the enclosure  
into a cabinet.  
7. Establish host connection. See Chapter 4 for host connection.  
3-3  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Fibre Channel Setup  
This chapter covers Fibre Channel device configuration and option settings. All  
Fibre Channel 15-bay units have built-in SES on the personality card. Refer to  
Chapter 8 for SES operation. Please take note of the installation warnings below  
before beginning setup.  
WARNING: Take care when connecting the unit to an AC power source to  
ensure that it is plugged-in to a circuit of the appropriate rating (110v or  
220v). For safe operation, the circuit should have over-current protection  
to prevent damage to the unit in the event of circuit overloading.  
WARNUNG: Vergewissern Sie sich, daß die Netzspannung (220V / 110V)  
korrekt eingestellt ist, bevor Sie das Gerät mit dem Stromnetz verbinden.  
Zur Sicherheit sollte das Netz über einen Überspannungsschutz zur  
Vermeidung von Schäden im Falle einer Überlast verfügen.  
WARNING: When connecting the unit to an AC outlet or power strip, ensure  
that the outlet has the proper connection for grounding. The AC power  
cables included with the unit have three prongs, one of which is used for  
the ground connection. Do not use a two prong AC cable with the unit  
since this will not allow for proper unit grounding and could cause  
problems with normal unit operation.  
WARNUNG: Bei der Verbindung der Unit mit einer Steckdose oder einer  
Verteilerdose sollten sie auf eine korrekte Erdung derselben achten. Die  
mitgelieferten Kaltgeräteanschlußkabel habe 3 Kontakte, von denen  
einer zur Erdung verwendet wird. Verwenden Sie kein Stromkabel mit 2  
Anschlüssen, da dieses keine korrekte Erdung ermöglicht und Probleme  
während des regulären Betriebs verursachen kann.  
Slot Settings  
The pictures to the right and below show the slot  
numbering sequence and the default ID settings.  
Slot 0, ID 0  
Default ID settings are based on both ID rotary  
switches set to a value of 0.  
Slot 1, ID 1  
Slot 2, ID 2  
Slot 3, ID 3  
Slot 4, ID 4  
Slot 5, ID 5  
Slot 6, ID 6  
Slot 7, ID 7  
Slot 8, ID 8  
Slot 9, ID 9  
Slot 10, ID 10  
Slot 11, ID 11  
Slot 12, ID 12  
Slot 13, ID 13  
Slot 14, ID 14  
4-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Setting ID  
Rotary switch settings only affect Slot 0 and all other slots are sequentially  
increased by a value of one after that slot.  
The ID is set sequentially starting from a base address. The base address, or  
starting address, is set via a 0-7 position rotary switch located on the personality  
module. There is a second 0-15 position rotary switch which can be changed to  
modify the base address setting.  
The default value for both switches is 0. In this default configuration, the device ID  
values are as shown.  
The 0-7 switch is used to set the  
base address which is multiplied  
by 16, and the 0-15 switch is  
used to set the offset modifier to  
the base address. The formula  
for setting the ID is: x(16)+y,  
where x is the 0-7 switch and y is  
the 0-15 switch.  
SW1 - ID  
setting 0-15  
SW2 - ID  
setting 0-7  
Ex. The 0-7 switch is set to 2, the 0-15 switch is set to 6. This sets the base address  
to 38 (2*16=32, +6=38). So Slot 0 ID = 38, Slot 1 ID = 39, Slot 2 ID = 40, Slot 3  
ID = 41, etc… up to Slot 9 ID = 47.  
The table below provides the Slot 0 Starting (Base) Address Settings.  
MSB  
0
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
8
9
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
97  
98  
99  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
10 (A) 10  
11 (B) 11  
12 (C) 12  
13 (D) 13  
14 (E)  
15 (F)  
14  
15  
4-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ID Conflict  
When two devices share the same ID, a conflict occurs. This should not happen  
unless two or more enclosures are daisy chained together. If devices in one  
enclosure conflict with devices in another enclosure, the devices will re-arbitrate  
ID and resolve the conflict.  
Option Settings  
Three option settings are located on the personality card. To access the jumpers,  
the cover must be removed. The figure below shows the location of the option  
settings on the personality card.  
W1*  
Delayed Start  
& Remote Start  
* Located on the mid-plane board.  
Delayed Start Option Jumper  
Header W1 pins 1 & 2.  
Jumper on = enabled.  
Jumper off = disabled (default).  
Remote Start Option Jumper  
Header W1 pins 3 & 4.  
Jumper on = enabled.  
Jumper off = disabled (default).  
Front Status LEDs  
A status indicator is located on each canister. A 'Blue' light indicates normal  
drive activity. A 'Red' light indicates a device fault. If all canisters display a 'Red'  
light that is blinking on and off it indicates that there is a system fault. A system  
fault is either a power supply or blower failure. Check the back of the unit to  
determine which fault has occurred. Refer to Chapter 5 for blower fault indicator  
location and to Chapter 6 for power supply fault indicator location.  
Status  
A blue light on a single canister  
indicates device activity or busy.  
Indicators  
A red light on a single canister  
indicates a device fault.  
4-3  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
External I/O Connection  
The external I/O connections are located on both the personality card and the  
contoller card. There are five SFP I/O connectors accessible from the rear of the  
unit as shown in the figure below.  
RS232 for Ethernet for Host/Drive Drive  
Controller 0 Controller 0 CH 3  
CH 5  
Host/Drive  
CH 4  
Host  
CH 1  
Host  
CH 0  
Host/Drive  
CH 5  
Ethernet for  
Controller 1  
Drive  
CH 2  
RS232 for  
Controller 1  
Host/Drive  
CH 4  
Host  
CH 0  
Host  
CH 1  
Host CH-0 and CH-1 (Bottom)  
Input connections for Host Loops 0 and 1. These are Standard (2Gb/s) SFP  
transceiver connectors used to connect to host systems from controller 1.  
Host CH-0 and CH-1 (Top)  
Input connections for Host Loop 0 and 1. These are Standard (2Gb/s) SFP  
transceiver connectors used to connect to host systems from the controller 0.  
CH 2 (Bottom)  
This is a standard (2Gb/s) SFP transceiver connector used to connect to a drive  
expansion enclosure for Loop A side of drives. The 15 internal drives loop side A  
are connected to this loop as well.  
4-4  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CH 3 (Top)  
This is a standard (2Gb/s) SFP transceiver connector used to connect to a drive  
expansion enclosure for Loop B side of drives. The 15 internal drives loop side B  
are connected to this loop as well.  
CH 4  
This is a standard (2Gb/s) SFP transceiver connector used to connect to a host  
system or drive expansion bay. Host or disk connection is firmware selectable.  
CH 5  
This is a standard (2Gb/s) SFP transceiver connector used to connect to a host  
system or drive expansion bay. Host or disk connection is firmware selectable.  
RS232 Controller 0  
RS232 Serial Connection to the 5251F6 controller 0.  
RS232 Controller 1  
RS232 Serial Connection to the 5251F6 controller 1.  
4-5  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Blower Operation  
This chapter covers all operations of the blowers for 15-bay units. Refer to  
Chapter 1 for blower specifications. The blower is hot swappable and can be  
removed or installed while the enclosure continues to function, however, failure  
to replace a non-working blower within a reasonable period of time may expose  
drives to extreme heat, which could cause loss of data.  
WARNING: Blowers are a system critical component. Non-operating blowers  
should be replaced as soon as possible to avoid data loss or device failure.  
WARNUNG: Gebläse sind für die Funktion wichtige Komponenten. Nicht  
funktionierende Gebläse sollten so schnell wie möglich ersetzt werden,  
um Datenverluste oder Fehlfunktionen zu vermeiden.  
The blowers are located on the back of the  
unit and each have its own fault LED that  
will light if the blower is non-operational.  
Fault LED  
Blower Removal/Insertion  
The blower is designed to be easily installed and removed.  
1. Unfasten the blower thumbscrew by  
turning counterclockwise. A Philips  
head screwdriver can be used if the  
thumbscrew is too tight to turn by hand.  
2. Remove the blower sled by pulling out  
on the handle and grasping the side of  
the blower tray. Wait for the blower to  
stop completely before removing it  
from the unit.  
Reverse the steps to reinstall the blower.  
WARNING: To prevent injury when removing or installing the blower, do not  
grab the bottom of the tray which is used for blower access intake. The  
blower operates at high speeds and continues to spin for a short time  
after power is disconnected.  
WARNUNG: Um Verletzungen während der Entfernung oder Installation des  
Gebläses zu vermeiden, berühren Sie nicht dessen Unterseite, da hier  
der Lufteintritt erfolgt. Das Gebläse arbeitet mit hohen  
Geschwindigkeiten und läuft nach Abschalten der Versorgungsspannung  
noch einige Zeit nach.  
5-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
WARNING: Avoid direct contact with the blower intake access hole while the  
blower is running. The blower operates at high speeds and can cause  
injury.  
User’s removing or installing a blower must be awarre  
of the blower access hole. Contact with the access hole  
must be avoided while the blower is running to  
prevent injury.  
Blower Replacement  
If the blower has stopped running or the fault LED indicator is lit, the blower may  
need to be replaced. Before replacing, the cable connection should be checked to  
ensure that the connector is firmly seated and that there is nothing blocking the  
blower blades that could cause interference.  
If you believe a blower is in a nonfunctional state, please contact the place of  
purchase for repair or replacement.  
The JMR part number for a replacement blower is shownbelow. The assembly  
includes the tray along with the blower.  
Model  
JMR Part Number  
15-bay  
SBA-05207  
5-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. Power Supply Operation  
This chapter covers all operations of the power supplies. For operation, the AC  
cord (included) must be connected to the AC Inlet on each supply, and the power  
supply must be switched ON. The 'OK LED' will light to indicate the power  
supply is functioning properly. If the power supply experiences a problem and  
cannot operate within its normal specifications, the Fault LED will light and the  
power supply will shut itself off.  
The power supplies also have their own fan included to maintain proper cooling  
within each supply and also provide some additional, but minimal airflow through  
the rest of the enclosure.  
Thumbscrew  
Handle  
On/Off Switch  
Fault LED  
AC Inlet  
OK LED  
Power Supply Removal/Insertion  
Follow the following steps to either remove a power supply in a 15-bay unit.  
1. Unfasten the power supply thumbscrew by  
turning counterclockwise. A Philips head  
screwdriver may be used if the thumbscrew is  
too tight to turn by hand.  
2. Remove by pulling out on the handle.  
Reverse the steps to reinstall the power supply.  
6-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Low Power Mode (Standby Power)  
When both power supplies are turned off, the unit will switch to low power or  
standby mode and the power supply fans will continue to run. The unit blowers  
will remain operational if a single power supply is turned off, not installed, or  
fails, in order to maintain the proper low temperature within the unit. To stop the  
power supply fans and turn the unit off completely, it must be disconnected from  
the AC power source.  
Power Supply Replacement  
If the Power Supply Fault LED indicator is lit, the power supply may need to be  
replaced. Before replacing, the power supply should be turned off, removed from  
the enclosure, and reinstalled. The AC cable connection should be checked to  
ensure that the connector is firmly seated and the power supply should be firmly  
inserted with the thumbscrew tightly securing it. If the Fault LED indicator is still  
coming on, then the power supply should be replaced.  
If the fan in the power supply is not functioning but the power supply still works,  
the power supply unit should be replaced as soon as possible. Leaving the power  
supply running without the fan could cause the power supply to overheat and  
shutdown at any time.  
If you believe a power supply is in a nonfunctional state, please contact the place  
of purchase for repair or replacement.  
JMR part number for a replacement power supply is shown below. The assembly  
includes the power supply installed in the canister.  
Model  
JMR Part Number  
15-bay  
PSS-00766  
SAFETY TIP: Both power supplies should be installed into the unit at all times  
to maintain proper cooling and airflow within the enclosure. In the event  
of a power supply failure, the faulty supply should be left in the enclosure  
until a replacement power supply is available.  
6-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. FR15 Cabinet Installation  
This chapter covers the installation of the Rackmount enclosure into a standard  
19" (483mm) wide and 30" (762mm) to 36" (914mm) deep cabinet that meets the  
EMA/RETMA standards.  
Before beginning rail installation, please take note of the following precautions:  
NOTE: When installing the unit into a cabinet or closed environment, the  
operating ambient temperature of the rack environment may be greater  
than the maximum recommended ambient temperature. Consideration  
must be taken to meet the maximum recommended ambient temperature  
(Tmra) for the best unit operation.  
HINWEIS: Wenn das Gerät in einen Gehäuseschrank oder eine sonstige  
geschlossene Umgebung verbaut wird, kann die Umgebungstemperatur  
über die maximal zulässige Betriebstemperatur ansteigen. Maßnahmen  
bzgl. der maximalen, empfohlenen Betriebstemperatur (Tmra) müssen  
getroffen werden, um eine bestmögliche Funktion des Gerätes zu  
gewährleisten.  
WARNING: Ensure that the front and back of the unit are not blocked when  
installing the unit into a cabinet or closed area. Blocking the front or  
back of the unit can cause reduced air- flow that will compromise the  
safe operating environment within the unit.  
WARNUNG: Vergewissern Sie sich, daß das Gerät an Vorder- und Rückseite  
nicht abgedeckt ist, wenn das Gerät in einem Gehäuseschrank oder  
einer geschlossenen Umgebung verbaut wird. Abdeckung der Vorder-  
und Rückseite kann verminderte Kühlung zur Folge haben und somit  
sichere Betriebsbedingungen negativ beeinflussen.  
WARNING: When loading the unit into a cabinet, ensure that a hazardous  
condition is not achieved due to uneven mechanical loading. To prevent  
injury, remove the power supplies and drives before loading, and re-  
install them after the unit has been secured in the cabinet.  
WARNUNG: Vermeiden Sie während des Einbaus des Gerätes in einen  
Gehäuseschrank jegliche gefährliche Aktionen, selbst wenn diese nur  
mechanischer Art sind. Um Verletzungen zu vermeiden, entfernen Sie  
die Netzteile und Laufwerke vor der Montage und installieren Sie diese  
erst erneut, wenn das Gerät im Gehäuseschrank gesichert  
ist.Vergewissern Sie sich, daß das Gerät an Vorder- und Rückseite nicht  
abgedeckt ist.  
7-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Rail Mounting Kit Hardware  
Ten #10-32 Screws  
Four each #8-32 Screws/Washers/Nuts  
Spare Hardware Parts  
Check with a JMR Sales Representative for pricing and availability of spare  
hardware parts.  
Description  
#10-32 Screw  
#8-32 Screw  
#8-32 Nut  
JMR Part Number  
HDS-01580  
HDS-00350  
HDN-00040  
#8-32 Washer  
HDW-00080  
Rail Installation  
A completed rail assembly without the unit uinstalled would look like this:  
Two #8-32 screw  
Two #10-32  
assemblies  
screws  
Two #10-  
32 screws  
Cabinet/Unit  
Front  
1. Affix the extension brackets to the main rail using the #8-32  
screw/washer/nut assemblies. Adjust to the correct length for the cabinet  
depth being used.  
7-2  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Extension Bracket  
2. Affix the extension bracket to  
the rear of the unit using two  
#10-32 screws. There are 3  
holes in the extension bracket  
for mounting. Depending on the  
hole pattern that is being used in  
the cabinet, two holes should  
always be available for securing  
the extension bracket.  
3. The fronts of the rails  
have three holes. Two of  
the holes (top and  
bottom) are used to  
secure the rail to the  
cabinet. The middle  
hole is used to secure the  
enclosure to the rail and  
cabinet. Secure the front  
of each rail to the  
cabinet vertical rails  
using two #10-32 screws  
for each rail.  
7-3  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Slide the unit into the cabinet and secure it to the cabinet with a single  
#10-32 screw on each side.  
5. Snap the end cap over the screw on each side of the unit to finish the  
installation.  
7-4  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. SES Operation  
For bus management, the FORTRA Fibre channel enclosures have a built-in  
SES processor designed to meet the SFF-8067 specification. By using the SES (S-  
Link) connector on the back of the unit the SES bus management can be expanded  
to other FORTRA Fibre enclosures that don't have a SES processor of their own  
(2/4-bay units).  
In order to communicate with the SES processor, at least one device must be  
present in the enclosure.  
8-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
9. Infortrend 5251F6 Installation  
This model is designed to be used with up to two 5251F6 RAID bridge controllers  
from Infortrend. A total of six loops are provided. The table below indicates the  
possible host and disk combinations. RCC is used for inter controller  
communication when two controllers are installed. RCC occurs on either a  
dedicated loop or shared with a disk loop and is firmware selectable.  
# of Host # of Disk  
RCC  
Ports  
Ports  
4
2
2
4
Shared with drive loop  
Shared with drive loop  
Up to two 5251F6 controllers may be installed into the enclosure. All of the I/O  
and power connections are made at the rear of the unit. Additionally, the controller  
can be removed from the rear of the unit and the power supplies and blowers may  
be hot-swapped from the rear of the unit.  
Installation Steps  
1. Install each controller into the JMR controller canister provided and plug  
into the unit.  
2. Install up to 15, 3.5" hard disk drives into the device canisters using 4 screws  
per device (screws have been provided - JMR P/N HDS-01906) and install  
into the front of the unit. (Refer to Chapter 4)  
3. Plug in the two AC power cords to the AC inlet located on each power  
supply in the rear of the unit. Turn the power supplies on using the on/off  
switch located on each power supply.  
4. Connect the RS-232 port to the unit and configure the RAID set. See  
Chapter 4 for connector location and use.  
5. Connect the host I/O ports to a HBA or hub/switch and connect any  
expansion I/O ports to other devices. (Refer to Chapter 4)  
Default Slot ID  
Refer to Chapter 4 for default slot IDs.  
9-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10. Product Support  
For current information on this product, including updates to the manual and  
technical support related issues, please contact the sales support section of our  
directly at the address below.  
US Corporate Headquarters  
JMR Electronics, Inc.  
ATTN: Technical Support Division  
20400 Plummer St.  
Chatsworth, CA 91311  
Customer Support: (818) 739-1140  
Office Hours: Monday-Friday 8:00 A.M. to 5:00 P.M., Pacific Standard Time  
Manual Changes  
Revision A - Initial Release  
10-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A. Drive and Controller  
Manufacturers  
Drive Manufacturers  
Fujitsu  
Internet Address: www.fcpa.com  
Hitachi Global Storage Technologies  
Internet Address: www.hgst.com  
Maxtor  
Internet Address: www.maxtor.com  
Seagate Technology  
Internet Address: www.seagate.com  
RAID Controller Manufacturers  
Adaptec, Inc.  
Internet Address: www.adaptec.com  
Chaparral Network Storage  
Internet Address: www.chaparralnet.com  
Infortrend Corporation  
Internet Address: www.infortrend.com  
Intel ICP VORTEX (Intelligent Computer Peripherals)  
Internet Address: www.icp-vortex.com  
Mylex Corporation  
Internet Address: www.mylex.com  
Silicon Image, CMD Storage Systems  
Internet Address: www.cmd.com  
Host Bus Adapter Manufacturers  
Adaptec, Inc.  
Internet Address: www.adaptec.com  
Antares Microsystems  
Internet Address: www.antares.com  
Emulex Corporation  
Internet Address: www.emulex.com  
JNI Corporation  
Internet Address: www.jni.com  
QLogic Corp.  
Internet Address: www.qlogic.com  
A-1  
FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Invacare Bicycle XLT User Manual
Ives Door 7212V User Manual
Jenn Air Refrigerator 12642718 User Manual
JVC Camcorder GR AX227 User Manual
JVC Home Theater System GR D360 User Manual
Kambrook Fryer KDF100 User Manual
Kenmore Clothes Dryer HE3 User Manual
Kenmore Dishwasher 58714202 User Manual
Knoll Systems Stereo Amplifier MA1250 User Manual
Koss Switch KS5846 User Manual