FPD1000-HP SERIES
HIGH PRESSURE
Positive Displacement Flowmeters
Download from Www.Somanuals.com. All Manuals Search And Download.
To the owner:
INSTALLATION
Thank you for purchasing an OMEGA FPD
Series Flowmeter. Please take a few min-
utes to read through the manual before in-
stalling and operating your meter. If you
have any problems with the meter, refer to
the Maintenance and Troubleshooting sec-
tions of the manual.
1. Use thread sealant on all pipe threads.
2. Ensure the meter is installed so that
rotor shafts are always in a horizontal
plane (See Figure 1). Flow is bi-direc-
tional.
This manual contains connection and op-
erating instructions for the OMEGA FPD
Series meters with pulse outputs. This in-
cludes the following models:
Figure 1
DO NOT install
meter this way.
FPD1202-HP
FPD1203-HP
The OMEGA FPD Series flowmeter has in-
corporated the oval rotor principal into its
design. This has proven to be a reliable and
highly accurate method of measuring flow.
Exceptional repeatability and high accuracy
over a wide range of fluid viscosities and
flowrates are features of the OMEGA FPD
Series flowmeter design. With low pressure
drop and high pressure rating, means the
OMEGA FPD Series flowmeters are suit-
able for both gravity and pump (in-line) ap-
plications.
3. OMEGA recommends use of flexible
connections.
4. Extreme care must be taken when in-
stalling the meter. Pipe strain or over-
tightening meter connections can
cause meter damage.
PULSER DETAILS
Hall Effect Sensor Specifications
IMPORTANT INFORMATION
•
4.5 V to 24 V (4.6 - 9 mA) operation
needs only an unregulated supply.
Please read this information
!
▲
carefully before use!
•
Open collector 25 mA output NPN
(Current Sink) compatible with digital
logic.
Before use, confirm the fluid to be used is
compatible with the meter or consult with
OMEGA for advice.
•
Reverse battery precaution.
To prevent damage from dirt or foreign
matter, OMEGA recommends a Y or bas-
ket type 200 mesh strainer be installed as
close as possible to the inlet side of the
meter. (If required, contact OMEGA for fur-
ther information.)
Figure 2
Supply
Signal
Ground
X
To prevent damage to the meter, slowly fill
the system with fluid. This will prevent dam-
age caused by air purge.
NOTE: Failure to do this could damage the
meter.
Hall Effect Sensor Wiring Details
(HP Models Only)
For pump applications, turn off the pump
at the end of each day.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Reed Relay Specifications
Reassembly:
•
•
Two wire SPST N/O.
1. Replace rotors into the meter body. The
rotors should be at 90 degrees to each
other.
Switching voltage 150 VDC; maximum
current 0.25 Amps.
2. Lightly rotate the rotors by hand. They
must rotate freely.
•
•
Rating 3 watts.
Duty cycle 20% ON, 80% OFF.
3. Install O-ring.
4. Replace the meter cap and tighten the
eight screws uniformly to 35Nm (25 Ft.
Lbs.).
Figure 3
5. Replace the pulser cap and tighten the
four screws.
Reed Switch Wiring Details
(HP Models Only)
MAINTENANCE
Disassembly:
1. Ensure the fluid supply to the meter has
been disconnected, and the line pres-
sure has been released before disas-
sembly.
2. Remove the four screws and remove the
pulser cap.
3. Remove the gasket.
4. Remove eight screws and remove the
meter cap.
5. Remove O-ring and inspect. Replace O-
ring if damaged.
6. Remove rotors, clean and inspect. Re-
place rotors if damaged.
7. To remove the PCB, remove the two
screws.
NOTE: Reed Switch PCB’s cannot be re-
moved.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Symptom
Probable Cause
Corrective Action
FLUID WILL NOT
FLOW THROUGH
THE METER
1. Foreign matter blocking
rotors
Dismantle meter, clean rotors. Strainer must
be fitted in-line.
2. Line strainer blocked
3. Damaged rotors
Clean strainer.
Replace rotors. Strainer must be fitted in-line.
Re-adjust connections.
4. Meter connections over-
tightened
REDUCED FLOW
THROUGH THE
METER
1. Line strainer partially
blocked
Clean strainer.
2. Fluid is too viscous
Maximum viscosity 1000 centipoise.
METER READING 1. Fluid flowrate is too low
See specifications for minimum and
maximum flowrates.
INACCURATE
or too high
2. Air in fluid.
Bleed air from system.
3. Excess wear caused by
incorrect installation
Check meter for damage. Install correctly.
METER NOT
GIVING A PULSE
SIGNAL
1. Faulty Hall Effect sensor
or Reed Switch
Replace meter cap for Reed Switch models,
replace PCB for Hall Effect models.
2. Faulty magnet
Replace rotors.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
DISPLAY PARTS LISTING
Model: FPD1202-HP
3
4
9
TERMINAL
BLOCK
10
6
2
7
8
1
u = Recommended Spare Parts to stock.
Bold Text = Indicates Stainless Steel model parts.
Item
Rec.
Part or Set
No. Qty. Parts (Order from this column only) Part Description
1
2
3
3
4
6
6
7
8
1
8
1
1
4
1
1
2
1
1
1
1
MS1NS
MS367S
MS170H
MS170HN
MS115S
MS3HES
MS3HPS
MS6-1S
BS029V
Meter Body Assembly NPT
Bolt Set - Socket Head
Pulser Cap (BSP)
Pulser Cap (NPT)
Bolt Set - Socket Head
Meter Cap & Hall Effect Assembly
Meter Cap & Reed Switch Assembly
Rotor Set (Stainless Steel)
O-Ring (Viton)
O-Ring (Kalrez)
Gasket
u
u
*
*
u
u
u
8
9
10
BS029TE
MS300HS
MS284S
Screw Sets
Reed Switch & Hall Effect are unavailable without meter cap.
*
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Pulse Meter Models
Flow Ranges (LPM or GPM)
Above 5 centipoise
Below 5 centipoise
Accuracy of Reading
Maximum Viscosity
2 to 100 / 0.53 to 26.4
5 to 100 / 1.32 to 26.4
± 1%
1000 Centipoise
Maximum Operating Pressure
Maximum Operating Temperature
Pulse Type
Pulses per Litre/Gallons
Meter Dimensions
55160 kPa / 8000 PSI / 551 Bar
120°C / 248°F
Hall Effect Sensor / Reed Switch
1000 / 3785
86mm Dia. / 3.4” Dia. (Meter Body)
83mm / 3.25” (Port Face to Face)
3.3 kg / 116 oz.
Weight
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DISPLAY PARTS LISTING
Model: FPD1203-HP
3
4
9
TERMINAL
BLOCK
10
6
2
7
8
1
u = Recommended Spare Parts to stock.
Bold Text = Indicates Stainless Steel model parts.
Item
Rec.
Part or Set
No. Qty. Parts (Order from this column only) Part Description
1
2
3
3
4
6
6
7
7
7
7
8
8
9
10
1
8
1
1
4
1
1
2
2
2
2
1
1
1
1
MS2NS
MS367S
MS170H
MS170HN
MS115S
MS3HES
MS3HPS
MS7-1ES
MS7-1RS
MS7-1HES
MS7-1HRS
BS029V
BS029TE
MS300HS
MS284S
Meter Body Assembly NPT
Bolt Set - Socket Head
Pulser Cap (BSP)
Pulser Cap (NPT)
Bolt Set - Socket Head
Meter Cap & Hall Effect Assembly
Meter Cap & Reed Switch Assembly
Rotor Set (S/Steel) - Hall Effect
Rotor Set (S/Steel) - Reed Switch
Rotor Set (S/Steel) - Hall Effect, High Visc.
Rotor Set (S/Steel) - Reed Switch, High Visc.
u
u
*
*
u
u
u
u
u
u
O-Ring (Viton)
O-Ring (Kalrez)
Gasket
Screw Sets
Reed Switch & Hall Effect are unavailable without meter cap.
*
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Pulse Meter Models
Flow Ranges (LPM or GPM)
Above 5 centipoise
Below 5 centipoise
Accuracy of Reading
15 to 500 / 4.0 to 132
25 to 500 / 6.0 to 132
± 1%
Maximum Viscosity
1000 Centipoise
55160 kPa / 8000 PSI / 551 Bar
120°C / 248°F
Hall Effect Sensor / Reed Switch
400 / 1514
86mm Dia. / 3.4” Dia. (Meter Body)
83mm / 3.25” (Port Face to Face)
3.3 kg / 116 oz.
*
Maximum Operating Pressure
Maximum Operating Temperature
Pulse Type
Pulses per Litre/Gallons
Meter Dimensions
Weight
Unless high viscosity rotors are fitted.
*
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
M-4125 /0405
Download from Www.Somanuals.com. All Manuals Search And Download.
|