Heat Controller Inc Air Conditioner SMA 18 User Manual

INSTALLATION  
INSTRUCTIONS  
SMA/SMH 18/24  
Version C  
Single Zone Ductless Mini-Split System  
A/C and Heat Pump  
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
Installation Parts  
Please install the accessories attached with unit correctly according to this installation manual.  
**Cautions on remote  
Part No. Name of Part  
Quantity  
controller installation  
• Keep the remote controller at  
least 3 feet from the nearest  
TV set or stereo equipment  
to advoid possible electronic  
interference.  
• Do not leave the remote  
controller in a place exposed  
to direct sunlight or close to  
a heating source, such as a  
stove.  
1
2
3
4
5
6
Installation Plate  
1
8
8
1
1
2
Anchor  
Mounting Screw A (ST3.9x25-C-H)  
Remote Controller  
Remote Controller Holder  
Mounting Screw B (ST2.9x10-C-H)  
o 1/4" (<24,000 Btu/h)  
Liquid side  
• Ensure that the positive and  
negative poles are correct  
when inserting batteries into  
the remote controller.  
o 3/8" (≥24,000Btu/h)  
o 1/2" (<24,000 Btu/h)  
o 5/8" (≥24,000 Btu/h)  
7
Refrigerant Pipe  
Gas Side  
8
Seal*  
1
1
9
Drain Elbow*  
* See outdoor installation instructions  
9
Drain  
8
Seal  
Elbow  
Anchoring the Outdoor Unit  
• The outdoor unit should not be exposed  
to strong winds  
o
• Anchor the outdoor unit with 5/16"  
anchor bolts  
Remove the water receiver first  
before connecting the piipes  
U Bend example  
NOTICE: There should be at least two of the air flow inlets/  
oulets labeled “A”, “B”, “C” above free from blockage.  
2
SMA/SMH 18/24  
INSTALLATION INSTRUCTIONS  
Heat Controller, Inc.  
INDOOR UNIT INSTALLATION  
1. Mounting Installation Plate and creating a Wall opening  
Installation Plate and its measurements (inches):  
Clearance:  
Clearance:  
5 inches or more  
Clearance:  
5 inches or more  
Clearance:  
Clearance:  
Clearance:  
2. Creating a wall opening  
A.  
1. Attach the installation plate  
A.  
B.  
C.  
B.  
3
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
2. Line Set and Condensate Drain Line  
1. Condenstate Drain  
2. Line Set  
A. Run the drain hose sloping downward. DO  
NOT install the drain hose as illustrated below.  
Left rear piping  
Right rear piping  
A.  
B.  
B. When extending the drain hose, insulate  
appropriately.  
left-rear-hand piping,  
C.  
• Connect the indoor unit first, then the outdoor  
unit. Bend and arrange the piping carefully.  
• Do not allow the piping to loosen from the  
indoor unit during installation.  
• Be sure not to let the drain hose slack.  
• Insulate both pipes.  
• Do not allow the power cable and control cable  
to be crossed.  
4
SMA/SMH 18/24  
INSTALLATION INSTRUCTIONS  
Heat Controller, Inc.  
3. Indoor Unit Installation  
A.  
B.  
Place the upper lip at the back  
of the indoor unit onto the up-  
per hook of the installation plate.  
Move the indoor unit from side to  
side to see that is is secured onto  
the hook of the installation plate.  
C.  
Push the lower part of the indoor  
unit up to the wall. Then move  
the indoor unit from side to side  
and up and down to ensure it is  
secured to the installation plate.  
D. Piping can easily be installed by  
placing a piece of foam between  
the unit and the wall to assist in  
holding the unit away from the  
wall during installation.  
4. Electrical Work  
• Connect unit to a dedicated circuit.  
• Refer to the unit’s rating plate from proper supply voltage.  
A.  
B.  
C.  
D.  
E. All wiring to the unit and interconnecting between indoor and out-  
door units must comply with local and national electrical codes.  
F. Do not exceed the power code by splicing.  
G. Voltage should be in range of 90%~110% of unit’s voltage.  
H. The indoor unit is powered through the interconnecting cable. The  
indoor unit requires no separate power source.  
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
5. Connecting Cables  
A. Lift the panel, loosen the screw, then open the Electric Box Cover.  
B.  
C. Wrap cables not connected to terminals with electrical tape so that  
they will not touch any electrical components.  
6
SMA/SMH 18/24  
INSTALLATION INSTRUCTIONS  
Heat Controller, Inc.  
6. Piping and Wrapping  
A. For the left-hand and right-hand piping, remove the rear  
plate bushing from the left side of the rear plate.  
B. Wind the line set, drain hose and wiring with tape se-  
curely and evenly. Consult local and national electrical  
codes for proper routing and placement of electrical  
wiring.  
C. When installing the indoor unit lower than the outdoor  
unit, make a “u-bend” trap to prevent rain water from  
running along the connecting pipe to the inside of the  
building/room where the indoor unit is located.  
wrap  
line set.  
Before wrapping electrical wiring with line set, consult local and  
national codes for proper installation of line voltage wiring.  
7
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
OUTDOOR UNIT INSTALLATION  
1. Outdoor Installation Precaution  
• Install the outdoor unit on a rigid base to prevent noise and vibration.  
• Locate the air outlet direction where the discharged air is not blocked.  
Ensure there are no obstacles blocking the unit’s air flow.  
• If the installation location is exposed to strong winds, place the unit length  
wise along a wall or use shield plates to protect against high winds.  
• If suspending the unit, the installation wall should be solid brick, concrete or of similar construction. If  
not, reinforce the supporting wall. The connections between the bracket and wall and the bracket and  
the air conditioner must be firm, stable and reliable. Consult all local and national building codes.  
• If suspending the unit, follow the instructions provided by the bracket manufacturer.  
2. Drain Elbow Installation  
Fit the seal into the drain elbow,  
then insert the drain elbow into the  
outdoor unit’s base pan hole, rotate  
90° to securely assemble them. To  
discharge excessive condensate  
from the outdoor unit when in heating  
mode, connect the drain elbow to a  
drain hose (locally purchased).  
9
8
8
SMA/SMH 18/24  
INSTALLATION INSTRUCTIONS  
Heat Controller, Inc.  
3. Refrigerant Piping Connection  
1. Flaring  
2. Tightening Connection  
A.  
A.  
B.  
Hand tighten the flare nut and then tighten it  
with a spanner and torque wrench as shown.  
B.  
Excessive torque can break the flare nut. Ensure  
the proper torque is adhered to in the chart below.  
.04  
9
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
4. Wiring Connection  
A.  
B.  
C.  
D.  
E.  
F.  
Use a dedicated circuit. Use HACR break sized per  
unit’s rating plate. Size wires according to minimum  
circuit ampacity shown on the unit’s rating plate.  
• Be sure to comply with local and national electri-  
cal codes while running the wire from the indoor  
unit to the outdoor unit.  
• Install disconnects fro the outdoor and indoor  
units as required by national and local electrical  
codes.  
• Every wire must be connected firmly. Loose wir-  
ing may cause the terminal to overheat or result  
in unit malfunction. A fire hazard may also exsist.  
NOTE: To prevent wire from loosening, secure  
wires and/or cords under cord clamp.  
10  
SMA/SMH 18/24  
INSTALLATION INSTRUCTIONS  
Heat Controller, Inc.  
AIR PURGE AND TEST OPERATION  
1. Air Purge  
A.  
B.  
Completely tighten the flare nuts A, B, C, D.  
Connect the manifold valve charge hose to the  
charge port of the packed valve on the gas pipe  
side.  
Connect the charge hose to the vacuum  
pump.  
C.  
D.  
where L=Length  
is entering.  
E.  
F.  
• Open the valve stem until it hits against the stop.  
Do not try to open it further.  
• Securely tighten the valve stem cap with a  
spanner or wrench.  
-29.92 inHg.  
Torque the valve properly:  
Gas pipe side (0.38"): 23.5 N-cm (300 kgf-cm)  
Liquid pipe side (0.25"): 12.56 N-cm (160 kgf-cm)  
G.  
H.  
-
Hi Handle  
Lo Handle  
11  
Heat Controller, Inc.  
INSTALLATION INSTRUCTIONS  
SMA/SMH 18/24  
2. Gas Leak Check  
3. Test Operation  
Test the unit’s operation after completing gas leak  
check at all flare nut connections and complete  
an electrical safety check.  
Make sure connections do not leak  
with leak detector or soapy water.  
A.  
B.  
C.  
D.  
E.  
controlled by the remote controller to run in  
cooling mode. Manual operation must be used  
when the remote controller is disabled or when  
maintenance is necessary.  
A. Lo packed valve  
B. Hi packed valve  
C. End of indoor unit connection  
D. End of indoor unit connection  
F. The test operation should last about 30 minutes.  
12  
08/2010  

Agilent Technologies 6843A User Manual
AllerAir 8000 D Vocarb User Manual
Brother IntelliFAX 885MC User Manual
Carrier 50SX User Manual
Danby DPAC5009 User Manual
Danby DPAC10010 User Manual
Faria Instruments Commander User Manual
Hitachi RAS 80YHA User Manual
Honda Automobiles GX22 User Manual
Honda Power Equipment Automobile Parts GXV120 User Manual