Heat Controller Inc Air Conditioner RADS 183J User Manual

REG-183J  
REG-253J  
RADS-151J  
RADS-183J  
RADS-253J  
RAD-283J  
REG-183J-20A  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
Safety Precautions  
7RꢀSUHYHQWꢀLQMXU\ꢀWRꢀWKHꢀXVHUꢀDQGꢀSURSHUWꢀGDPDJHꢂꢀWKHꢀIROORZLQJꢀLQVWUXFWLRQVꢀPXVWꢀEHꢀ  
IROORZHGꢁꢀ,QFRUUHFWꢀRSHUDWLRQꢀGXHꢀWRꢀLJQRULQJꢀLQVWUXFWLRQVꢀPD\ꢀFDXVHꢀKDUPꢀRUꢀGDPDJHꢁꢀ  
7KHꢀVHULRXVQHVVꢀLVꢀFODVVL¿HGꢀE\ꢀWKHꢀIROORZLQJꢀLQGLFDWLRQVꢁ  
This symbol indicates the possibility of death or serious injury.  
WARNING  
!
This symbol indicates the possibility of injury or damage to property.  
!
CAUTION  
Meanings of symbols used in this manual are as shown below.  
Never do this.  
Always do this.  
!
WARNING  
!
Do not open the unit  
Always ensure  
Plug in power cord  
!
!
during operation  
plug properly  
effective grounding  
‡ꢀ2WKHUZLVHꢂꢀLWꢀPD\ꢀFDXVHꢀHOHFWULFꢀ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFN  
.  
‡ꢀ,QFRUUHFWꢀJURXQGLQJꢀPD\ꢀFDXVHꢀ  
VKRFNꢀRUꢀ¿UHꢀGXHꢀWRꢀH[FHVVꢀKHDWꢀ  
HOHFWULFꢀVKRFN  
JHQHUDWLRQ  
-  
Do not operate or stop  
the unit by inserting or  
Unplug the unit if  
Do not modify power  
!
!
strange sounds,  
cord length or share  
pulling out the power  
odors or smoke  
the outlet with other  
p
lu  
g
comes from it.  
appliances.  
‡ꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFNꢀRUꢀ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFNꢀRUꢀ  
¿UHꢀGXHꢀWRꢀKHDWꢀJHQHUDWLRQ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀ¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
¿UHꢀGXHꢀWRꢀKHDWꢀJHQHUDWLRQ  
Do not operate with  
Do not use the power  
Do not allow water  
wet hands or in a  
cord close to heating  
to run in to electric  
damp environment  
appliances  
parts  
‡ꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFN  
‡ꢀ,WꢀPD\ꢀFDXVHꢀIDLOXUHꢀRIꢀPDFKLQHꢀ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀ¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
RUꢀHOHFWULFꢀVKRFN  
Do not use the socket if  
Unplug the unit if  
Always install circuit  
breaker and a dedicated  
strange sounds,  
!
!
it is loose or damaged  
odors or smoke  
power circuit  
comes from it.  
‡ꢀ,QFRUUHFWꢀLQVWDOODWLRQꢀPD\ꢀFDXVHꢀ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀ¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
‡ꢀ,WꢀPD\ꢀFDXVHꢀ¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
Do not use the power  
'RꢀQRWꢀXVHꢀDꢀGDPDJHGꢀRUꢀXQVSHFL¿HGꢀSRZHUꢀFRUG  
FRUGꢀQHDUꢀÀDPPDEOHꢀJDVꢀ  
‡ꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFNꢀRUꢀ¿UH  
or combustiblies, such  
as gasoline, benzene,  
‡ꢀ,IꢀWKHꢀSRZHUꢀFRUGꢀLVꢀGDPDJHGꢂꢀLWꢀPXVWꢀEHꢀUHSODFHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢀRUꢀDQꢀ  
DXWKRUL]HGꢀVHULYFHꢀFHQWHUꢀRUꢀDꢀTXDOL¿HGꢀSHUVRQꢀLQꢀRUGHUꢀWRꢀDYRLGꢀDꢀKD]DUG  
thinner, etc.  
Do not disassemble or modify unit.  
‡ꢀ,WꢀPD\ꢀFDXVHꢀDQꢀH[SORVLRQꢀRUꢀ¿UH  
‡ꢀ,WꢀPD\ꢀFDXVHꢀIDLOXUHꢀDQGꢀHOHFWULFꢀVKRFN  
2
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
CAUTION  
!
Ventilate the room well  
:KHQꢀWKHꢀDLUꢀ¿OWHUꢀLVꢀWRꢀEHꢀ  
Do not allow water to  
!
when used together with  
r
e
m
o
v
e
d
,
d
o
n
o
t
t
o
u
cht  
he  
enter inside the unit  
gas stove or if there is  
a gas leak  
HJUDGHꢀ
G
a
metal parts of the unit  
during cleaning  
‡ꢀ:  
D
WH  
U
PD\  
ꢀH  
QW  
H
Uꢀ  
W
KH  
X
Q
LWꢀD  
Q
G
‡ꢀ,WꢀPD\ꢀFDXVHꢀDQꢀLQMXU\ꢀGXHꢀWRꢀVKDUSꢀ  
WKHꢀLQVXODWLRQꢁꢀ,WꢀPD\ꢀFDXVHꢀDQꢀ  
HGJHVꢀRIꢀFRPSRQHQWVꢁ  
‡ꢀꢀ$QꢀR[\JHQꢀVKRUWDJHꢀPD\ꢀRFFXU  
‡ꢀꢀ0D\ꢀFDXVHꢀH[SORVLRQꢂꢀ¿UHꢀDQGꢄRUꢀ  
EXUQV  
HOHFWULFꢀVKRFN  
Turn off the main power  
When the unit is to be  
Hold the plug by the  
!
!
switch when not using  
cleaned, switch off, and  
head of the power plug  
the unit for a long time  
turn off the circuit breaker  
when taking it out  
‡ꢀꢀ,WꢀPD\ꢀFDXVHꢀHOHFWULFꢀVKRFNꢀDQGꢀ  
‡ꢀꢀ'RꢀQRWꢀFOHDQꢀXQLWꢀZKHQꢀSRZHUꢀLVꢀRQꢀDVꢀ  
‡ꢀꢀ,WꢀPD\ꢀFDXVHꢀIDLOXUHꢀRIꢀSURGXFWꢀRUꢀ¿UH  
GDPDJH  
LWꢀPD\ꢀFDXVHꢀ¿UHꢀDQGꢀHOHFWULFꢀVKRFN  
$OZD\VꢀLQVHUWꢀWKHꢀ¿OWHUVꢀ  
Stop operation and close  
Ensure that the instal-  
!
!
!
VHFXUHO\ꢁꢀ&OHDQꢀ¿OWHUꢀ  
the window in storm or  
lation bracket of the  
once every two weeks  
outdoor appliance is  
hurricane  
not damaged  
‡ꢀꢀ2SHUDWLRQꢀZLWKꢀZLQGRZVꢀRSHQHGꢀPD\ꢀ  
‡ꢀꢀ2SHUDWLRQꢀZLWKRXWꢀ¿OWHUVꢀPD\ꢀFDXVHꢀ  
DOORZꢀUDLQꢀWRꢀHQWHUꢀLQVLGHꢀDQGꢀGDPDJHꢀ  
IDLOXUH  
‡ꢀꢀ,IꢀEUDFNHWꢀLVꢀGDPDJHGꢂꢀWKHUHꢀLVꢀFRQFHUQꢀ  
SURSHUW\  
‡ꢀꢀ2SHUDWLRQꢀZLWKꢀGLUW\ꢄFORJJHGꢀ¿OWHUVꢀ  
RIꢀGDPDJHꢀGXHꢀWRꢀIDOOLQJꢀRIꢀXQLWꢁ  
PD\ꢀFDXVHꢀIDLOXUH  
Do not place obstacles  
Do not drink water  
Do not place heavy ob-  
around air-inlets or inside  
drained from air condi-  
ject on the power cord  
of air-outlet  
tioner  
and ensure that the  
cordisnotcompressed  
‡ꢀꢀ,WꢀFRQWDLQVꢀFRQWDPLQDQWVꢀDQGꢀFRXOGꢀ  
‡ꢀꢀ,WꢀPD\ꢀFDXVHꢀIDLOXUHꢀRIꢀDSSOLDQFHꢀRUꢀ  
PDNHꢀ\RXꢀVLFN  
DFFLGHQW  
‡ꢀꢀ7KHUHLVGDQJHUꢀRIꢀ¿UHRUHOHFWULF
VKRFN  
Do not use strong deter-  
gents such as wax or thin-  
Use caution when un-  
If water enters the unit,  
!
packing and installing  
turn the unit off at the  
power outlet and switch  
ner; use a damp, soft cloth  
off the circuit breaker.  
Isolate supply by taking  
‡ꢀꢀ6KDUSꢀHGJHVꢀFRXOGꢀFDXVHꢀLQMXU\  
‡ꢀꢀ$SSHDUDQFHꢀPD\ꢀEHꢀGHWHULRUDWHGꢀ  
GXHꢀWRꢀFKDQJHꢀRIꢀSURGXFWꢀFRORUꢀRUꢀ  
power-plug out and con-  
VFUDWFKLQJꢀRIꢀLWVꢀVXUIDFH  
WDFWꢀDꢀTXDOL¿HGꢀVHUYLFHꢀ  
technician  
‡ꢀ:DWHUꢀPD\ꢀHQWHUꢀWKHꢀXQLWꢀDQGꢀGHJUDGHꢀ  
WKHꢀLQVXODWLRQꢁꢀ,WꢀPD\ꢀFDXVHꢀDQꢀ  
HOHFWULFꢀVKRFN  
3
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING  
For your safety  
NOTE For some models, the power  
Do not store or use gasoline or other flammable vapors and liquids in  
supply cord with this air conditioner  
contains a current detection device  
designed to reduce the risk of fire.  
the vicinity of this or any other appliance.  
Avoid fire hazard or electric shock. Do not use an extension cord or an  
adaptor plug. Do not remove any prong from the power cord.  
3OHDVHꢀUHIHUꢀWRꢀWKHꢀVHFWLRQꢀ³2SHUDWLRQꢀ  
RIꢀ&XUUHQWꢀ'HYLFH´ꢀIRUꢀGHWDLOVꢁ  
WARNING  
Electrical Information  
In the event that the power supply  
cord is damaged, it cannot be  
Be sure the electrical service is adequate for the model you have  
chosen. This information can be found on the serial plate, which  
is located on the side of the cabinet and behind the grille.  
Be sure the air conditioner is properly grounded. To minimize  
shock and fire hazards, proper grounding is important. The power  
cord is equipped with a three-prong grounding plug for protection  
against shock hazards.  
repaired-it must be replaced with a  
cord from the Product Manufacturer.  
Do not, under any  
circumstances, cut,  
remove, or bypass  
the grounding prong.  
Your air conditioner must be used in a properly grounded wall  
receptacle. If the wall receptacle you intend to use is not adequately  
grounded or protected by a time delay fuse or circuit breaker,  
have a qualified electrician install the proper receptacle.  
Ensure the receptacle is accessible after the unit installation.  
Do not run air conditioner without side protective cover in place.  
This could result in mechanical damage within the air conditioner.  
Do not use an extension cord or an adapter plug.  
Power supply cord  
with 3-prong grounding plug  
and current detection device  
4
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
8QLWꢀPD\ꢀYLEUDWHꢀDQGꢀPDNHꢀQRLVHꢀ  
EHFDXVHꢀRIꢀSRRUꢀZDOOꢀRUꢀZLQGRZꢀ  
FRQVWUXFWLRQꢀRUꢀLQFRUUHFWꢀLQVWDOODWLRQꢁ  
3LQJLQJꢀRUꢀ6ZLVKLQJ  
'URSOHWVꢀRIꢀZDWHUꢀKLWWLQJꢀFRQGHQVHUꢀ  
GXULQJꢀQRUPDOꢀRSHUDWLRQꢀPD\ꢀFDXVHꢀ  
SLQJLQJꢀRUꢀVZLVKLQJꢀVRXQGVꢁ  
*XUJOLQJꢀRUꢀKLVVLQJꢀQRLVHꢀPD\ꢀ  
EHꢀKHDUGꢀGXHꢀWRꢀUHIULJHUDQWꢀ  
SDVVLQJꢀWKURXJKꢀHYDSRUDWRUꢀ  
GXULQJꢀQRUPDOꢀRSHUDWLRQꢁ  
Outdoor Temp:  
64.4-109.4°F (18-43°C) (T1 Environment)  
62.6-89.6°F (17-32°C) (T1 Environment)  
23.0-75.2°F (-5-24°C) (T1 Environment)  
32.0-80.6°F (0-27°C) (T1 Environment)  
69.8-125.6°F (21-52°C) (T3 Environment)  
62.6-89.6°F (17-32°C) (T3 Environment)  
19.4-75.2°F (-7-24°C) (T3 Environment)  
32.0-86.0°F (0-30°C) (T3 Environment)  
Cooling operation  
Heat operation  
Indoor Temp:  
Outdoor Temp:  
Indoor Temp:  
Remote  
signal  
receptor  
NOTEꢃꢀ&OHDUꢀ$LUꢀDQGꢄRUꢀ)ROORZꢀ0HꢀIHDWXUHVꢀRQO\ꢀDSSO\ꢀWRꢀFHUWDLQꢀPRGHOVꢁꢀ<RXUꢀ  
FRQWUROꢀSDQHOꢀPD\ꢀRUꢀPD\ꢀQRWꢀKDYHꢀWKHUHꢀIHDWXUHVꢀDQGꢀGLVSOD\ꢀOLJKWVꢁꢀ  
&KHFNꢀWKHꢀDFWXDOꢀXQLWꢀ\RXꢀSXUFKDVHGꢀWRꢀGHWHUPLQHꢀLIꢀWKHVHꢀRSWLRQVꢀDSSO\ꢁ  
5
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
TO CHANGE TEMPERATURE SETTING:  
3UHVVꢀRUꢀKROGꢀHLWKHUꢀ7HPSꢄ7LPHUꢀ8SꢀꢅꢀꢀꢀꢀꢆꢀRUꢀ'RZQꢀ  
ꢅꢀꢀꢀꢀꢆꢀEXWWRQꢀXQWLOꢀWKHꢀGHVLUHGꢀWHPSHUDWXUHꢀLVꢀVHHQꢀRQꢀ  
WKHꢀGLVSOD\ꢁꢀ7KLVꢀWHPSHUDWXUHꢀZLOOꢀEHꢀDXWRPDWLFDOO\ꢀ  
PDLQWDLQHGꢀDQ\ZKHUHꢀEHWZHHQꢀꢇꢈƒ)ꢀꢅꢉꢊƒ&ꢆꢀDQGꢀꢋꢇƒ)ꢀ  
ꢅꢌꢍƒ&ꢆꢁꢀ,Iꢀ\RXꢀZDQWꢀWKHꢀGLVSOD\ꢀWRꢀUHDGꢀWKHꢀDFWXDOꢀURRPꢀ  
WHPSHUDWXUHꢂꢀVHHꢀWRꢀ³2SHUDWHꢀRQꢀ)DQꢀ2QO\´ꢀVHFWLRQꢁ  
7KHꢀIDQꢀVSHHGꢀEXWWRQꢀLVꢀXVHGꢀWRꢀVHOHFWꢀWKHꢀ)DQꢀ6SHHGꢀ  
LQꢀIRXUꢀVWHSVꢃꢀ$XWRꢂꢀ/RZꢂꢀ0HGꢀRUꢀ+LJKꢁꢀ(DFKꢀWLPHꢀWKHꢀ  
EXWWRQꢀLVꢀSUHVVHGꢂꢀWKHꢀIDQꢀVSHHGꢀPRGHꢀLVꢀVKLIWHGꢁꢀ  
:KHQꢀWKHꢀXQLWꢀLVꢀRSHUDWLQJꢀLQꢀ'U\ꢀPRGHꢂꢀWKHꢀIDQꢀVSHHGꢀ  
LVꢀDXWRPDWLFDOO\ꢀFRQWUROOHGꢀDWꢀ/RZꢀIDQꢀVSHHGꢁ  
6
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
DQGꢀ)DQꢁꢀ7KHꢀLQGLFDWRUꢀOLJKWꢀEHVLGHꢀWKHꢀVHOHFWHGꢀPRGHꢀZLOOꢀ  
LOOXPLQDWHꢀDQGꢀUHPDLQꢀRQꢀRQFHꢀWKHꢀPRGHꢀLVꢀVHOHFWHGꢁ  
To operate in Auto feature:  
:KHQꢀ\RXꢀVHWꢀWKHꢀDLUꢀFRQGLWLRQHUꢀWRꢀ$872ꢀPRGHꢂꢀLWꢀ  
ZLOOꢀDXWRPDWLFDOO\ꢀVHOHFWꢀFRROLQJꢂꢀKHDWLQJꢀRUꢀIDQꢀRQO\ꢀ  
GHSHQGLQJꢀRQꢀZKDWꢀWHPSHUDWXUHꢀ\RXꢀKDYHꢀVHOHFWHGꢀDQGꢀ  
WKHꢀURRPꢀWHPSHUDWXUHꢁ  
7KHꢀDLUꢀFRQGLWLRQHUꢀZLOOꢀFRQWUROꢀURRPꢀWHPSHUDWXUHꢀ  
DXWRPDWLFDOO\ꢀDURXQGꢀWKHꢀWHPSHUDWXUHꢀVHWꢀSRLQWꢀVHOHFWHGꢁ  
To operate in Fan only:  
8VHꢀWKLVꢀIXQFWLRQꢀZKHQꢀFRROLQJꢀLVꢀQRWꢀGHVLUHGꢂꢀVXFKꢀDVꢀ  
IRUꢀURRPꢀDLUꢀFLUFXODWLRQꢀRUꢀWRꢀH[KDXVWꢀVWDOHꢀDLUꢀꢅRQꢀVRPHꢀ  
PRGHOVꢆꢁꢀ5HPHPEHUꢀWRꢀRSHQꢀWKHꢀYHQWꢀGXULQJꢀWKLVꢀIXQFWLRQꢂꢀ  
EXWꢀNHHSꢀLWꢀFORVHGꢀGXULQJꢀFRROLQJꢀIRUꢀPD[LPXPꢀFRROLQJꢀ  
HI¿FLHQF\ꢁꢀ<RXꢀFDQꢀFKRRVHꢀDQ\ꢀIDQꢀVSHHGꢀ\RXꢀSUHIHUꢁ  
To operate in Dry mode:  
,QꢀWKLVꢀPRGHꢂꢀWKHꢀDLUꢀFRQGLWLRQHUꢀZLOOꢀJHQHUDOO\ꢀRSHUDWHꢀLQꢀ  
WKHꢀIRUPꢀRIꢀDꢀGHKXPLGLIHUꢀWRꢀUHPRYHꢀKXPLGLW\ꢀIURPꢀWKHꢀDLUꢁꢀ  
+RZHYHUꢂꢀVRPHꢀGHJUHHꢀRIꢀFRROLQJꢀZLOOꢀFRQWLQXHꢁ  
7
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
AIR CONDITIONER FEATURES (CONTINUED)  
TIMER: AUTO START/STOP FEATURE  
3UHVVꢀRUꢀKROGꢀWKHꢀ7HPSꢄ7LPHUꢀ83ꢀRUꢀ'2:1ꢀEXWWRQꢀWRꢀ  
FKDQJHꢀWKHꢀ$XWRꢀWLPHꢀE\ꢀꢍꢁꢎꢀKRXUꢀLQFUHPHQWVꢂꢀXSꢀWRꢀꢉꢍꢀ  
KRXUVꢂꢀWKHQꢀFRXQWꢀGRZQꢀWKHꢀWLPHꢀUHPDLQLQJꢀXQWLOꢀVWDUWꢁ  
8
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
AIR CONDITIONER FEATURES (CONTINUED)  
THE DISPLAYS  
ꢏꢀ7KHꢀFRQWUROꢀLVꢀFDSDEOHꢀRIꢀGLVSOD\LQJꢀWHPSHUDWXUHꢀLQꢀGHJUHHꢀ  
)DKUHQKHLWꢀRUꢀGHJUHHVꢀ&HOVLXVꢁꢀ7RꢀFRQYHUWꢀIURPꢀRQHꢀWRꢀWKHꢀ  
RWKHUꢂꢀSUHVVꢀDQGꢀKROGꢀWKHꢀ/HIWꢀDQGꢀ5LJKWꢀ7HPSꢄ7LPHUꢀEXWWRQVꢀ  
DWꢀWKHꢀVDPHꢀWLPHꢂꢀIRUꢀꢌꢀVHFRQGVꢁ  
3
9
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
10  
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
11  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
12  
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
13  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
14  
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
15  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
16  
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
17  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
CARE AND CLEANING  
:$51,1*  
CAUTION  
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit  
before cleaning to prevent chock or fire hazards.  
Air Filter Cleaning  
The air filter should be checked at least once a  
month to see if cleaning is necessary. Trapped  
particles in the filter can build up and cause an  
accumulation of frost on the cooling coils.  
Push the vent handle to the Vent Closed position  
(where applicable).  
Open the front panel.  
Grasp the filter, pull up and out.  
Wash the filter using liquid dishwashing deter-  
gent and warm water. Rinse filter thoroughly.  
Gently shake excess water from the filter. Be  
sure the filter is thoroughly dry before replacing.  
Or, instead of washing you may vacuum the  
filter clean.  
ꢉꢍꢐƒ)ꢀꢅꢐꢍƒ&ꢆ  
Note: Never use hot water over to  
clean the air filter. Never attempt to operate the  
unit without the air filter.  
Cabinet Cleaning  
Be sure to unplug the air conditioner to prevent  
shock or fire hazard. The cabinet and front may  
be dusted with an oil-free cloth or washed with  
a cloth dampened in a solution of warm water  
and mild liquid dishwashing detergent. Rinse  
thoroughly and wipe dry.  
Never use harsh cleaners, wax or polish on the  
cabinet front.  
Be sure to wring excess water from the cloth before  
wiping around the controls. Excess water in or around  
the controls may cause damage to the air conditioner.  
Plug in air conditioner.  
Winter Storage  
If you plan to store the air conditioner during the winter,  
remove it carefully from the window according to the  
installation instructions. Cover it with plastic or return it  
to the original carton.  
18  
Owner’s Manual  
Room Air Conditioner with R-410A  
Heat Controller, Inc.  
TROUBLESHOOTING TIPS  
Before calling for service, review this list. It may save you time and expense. This list includes common  
occurrences that are not the result of defective workman-ship or materials in this appliance.  
Problem  
Solution  
Wall plug disconnected. Push plug firmly into wall outlet.  
Air conditioner  
does not start  
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or  
reset circuit breaker.  
Plug Current Device Tripped. Press the RESET button.  
Control is OFF. Turn Control ON and set to desired setting.  
Room temperature below  
62°F (17°C).  
rises above 1
6
2
°F  
(
1
7
°C.. Cooling may not occur until room temperature  
Air from unit does  
not feel cold  
enough  
Temperature sensing element touching cold coil, located behind air filter. Straighten  
tube away from coil.  
Reset to a Lower temperature.  
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for  
compressor to restart when set in the COOL mode.  
Outdoor temperature below 164°F  
(
1
8
°C  
).To defrost the coil, set FAN ONLY mode.  
Air conditioner  
cooling, but room  
is too warm- ice  
forming on cooling  
coil behind  
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost,  
set to FAN ONLY mode.  
Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY  
mode. Then, set temperature to a Higher setting.  
decorative front.  
Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.  
Air conditioner  
cooling, but room  
is too warm- NO  
ice forming on  
Temperature is set too High, set temperature to a Lower setting.  
Air directional louvers positioned improperly. Position louvers for better air distribution.  
cooling coil behind  
decorative front.  
Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution.  
Clear blockage in front of unit.  
Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.  
Unit recently turned on in hot room. Allow additional time to remove Stored heat from  
walls, ceiling, floor and furniture.  
Air conditioner turns on Dirty air filter- air restricted. Clean air filter.  
and off rapidly  
Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past  
cooling coils more frequently.  
Air movement sound. This is normal . If too loud, set to a slower FAN setting.  
Noise when unit is  
cooling  
Window vibration - poor installation. Refer to installation instructions or check with installer.  
the rear/outside to allow water drainage.  
Improper installation. Tilt air conditioner slightly to the
Water dripping  
INSIDE when  
unit is cooling.  
Refer to installation instructions - check with installer.  
19  
Heat Controller, Inc.  
Room Air Conditioner with R-410A  
Owner’s Manual  
Problem  
Solution  
Unit removing large quantity of moisture from humid room. This is normal during  
excessively humid days.  
Water dripping  
OUTSIDE when  
unit is cooling.  
Remote control not located within range. Place remote control within 20 feet & 180 ,  
radius of the front of the unit.  
Remote Sensing  
Deactivating  
Prematurely  
Remote control signal obstructed. Remove obstruction.  
(some models)  
Set temperature too low. Increase set temperature.  
Room too cold  
20  
11/2011  

Acura 2009 TSX 00X31 TL1 8001 User Manual
Brother LASER PRINTER MFC 8700 User Manual
Carrier RTU OPEN 11 808 427 01 User Manual
Cuisinart CWC 1200 User Manual
Epson Stylus C40UX User Manual
Friedrich Air Conditioner MR09C1H User Manual
Friedrich MR12C1H User Manual
Goodman Mfg IO GSH14 SP User Manual
Honda Automobiles HANDSFREELINK ACCORD User Manual
Honda Automobiles HP250 User Manual