Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
1.Driver
5.Torque wrench(17mm,22mm,26mm)
9.Nipper
12.Reamer
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
Accessory parts
Number
of
No. Accessory parts
articles
Remote controller
1
1
2
1
Optional parts for piping
Mark
Parts name
2
R-03 dry battery
A
Non-adhesive tape
Adhesive tape
B
C
D
3
Saddle(L.S) with screws
Mounting plate
Connecting electric cable
for indoor and outdoor
Drain hose
1
E
F
4
Drain hose
Heating insulating material
Piping hole cover
4X50
Steel nail, cement
G
5
6
4
Attention must be paid to
the rising up of drain hose
A
6
4X25
Screw
Plastic cap
1
1
7
8
Drain-elbow
Cover
Arrangement of piping directions
Rear left
C
Rear
right
Left
Cushion
4
1
9
Right
Below
10
11
Pipe supporting plate
Connecting cable
1
D
Note:Cooling only units don't have Drain-elbow
E
A
G
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
No.0010518787
500
140
113.5
113.5
140
583
140
415
140
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-24LEK13
HSU-18LEK03/(DB)
HSU-09LEK03/(DB)
HSU-12LEK03/(DB)
HSU-18LEK13
HSU-108CH09
HSU-138CH09
HSU-12LEK13-M
HSU-09LEK13
HSU-12LEK13
HSU-07LEK03
HSU-07HEK03
HSU-09LEK03
HSU-12LEK03
HSU-09HEK03
HSU-12HEK03
HSU-18HEK03
HSU-24HEK03
Selection of pipe
For 07 09 108
For 12 18 138
6.35mm(1/4")
12.7mm(1/2")
For 24
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
9.52mm(3/8")
15.88mm(5/8")
Liquid pipe (
Gas pipe
)
6.35mm(1/4")
9.52mm(3/8")
(
)
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 60mm
B= 60mm
HSU-24HEK03
HSU-24LEK13
A=145mm
B= 60mm
HSU-12LEK13-M
HSU-09LEK13
HSU-12LEK13
HSU-07LEK03
HSU-07HEK03
A=145mm
HSU-09LEK03
HSU-12LEK03
HSU-09HEK03
HSU-12HEK03
HSU-108CH09
HSU-138CH09
HSU-18HEK03
HSU-18LEK13
HSU-18LEK03/(DB)
HSU-09LEK03/(DB)
HSU-12LEK03/(DB)
A=145mm
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Indoor side
Wall hole
60mm
Outdoor side
Make a hole of 60 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
Thickness
of wall
G
Piping hole pipe
(Section of wall hole)
2
Indoor unit
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which
the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wi
is not correct, proper operation can not be carried out and will cause defect.
ring
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
Power cable:
3G1.0mm
Power cable:
5G1.0mm
3G1.0mm
3G1.0mm
Indoor unit
HSU-12HE K03
Outdoor unit
HSU-07HE K03
Indoor unit
Indoor unit
Outdoor unit
Outdoor unit
HSU-09HE K03
HSU-18HEK03
HSU-12LEK13-M
HSU-108CH09
HSU-138CH09
HSU-09LEK03
HSU-12LEK03
/
(DB)
/(DB)
Power cable:
3G1.5mm
connecting wiring:
3G1.5mm +1X0.75mm
Power cable:
3G2.5mm
3G2.0mm
Power cable:
3G1.0mm
4G0.75mm
HSU-18LEK13
Indoor unit
Outdoor unit
Indoor unit
HSU-24LEK13
Power cable:
3G1.5mm
Power cable:
3G2.5mm
Outdoor unit
4G0.75mm2
6G0.75mm
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
POWER
HSU-24HEK03
Outdoor unit
HSU-09LEK13
{
HSU-09LEK03
HSU-12LEK03
HSU-12LEK13
HSU-07LEK03
connecting wiring:
HSU-18LEK03/(DB)
BR
BL
POWER
SUPPLY
Outdoor unit
Y/G
-mod 07-12: 3G1.0mm
Power cable:
-mod 07-12: 3G1.0mm
3
Outdoor unit
Outdoor unit
1.Connection of pipes
To bend a pipe, give the roundness as large as possible not to crush the pipe
Connecting the pipe of gas side first makes working easier.
The max vertical distance between the indoor unit and the outdoor unit is 5 m.
Forced fastening without careful centering
may damage the threads and cause a
leakage of gas.
Half union
Flare nut
Fastening torque
Pipe Diameter (
)
Spanner
Liquid side 6.35mm(1/4")
Liquid side 9.52mm(3/8")
18N.m
40N.m
Torque wrench
Gas side 9.52mm(3/8")
Gas side 12.7mm(1/2")
40N.m
50N.m
Be careful that matters, such as wastes of sands, etc.
shall not enter the pipe.
Gas side 15.88mm(5/8")
60N.m
2.Attaching Drain-Elbow
If the drain-elbow is used, please attach it as
figure. (Note: Only for heat pump unit.)
3.Purging Method:
Push the air out of the indoor unit and piping as followes:
Tighten the caps on the valves with specified torque.
Tighten torque N.m
7-9
Valve rod
Valve cap
20-25
When connecting pipe exceeds 5 meters, 20g or 60g(only for 22k 24k) refrigerant shall be
added per exceeding meter. Charge according to the following list.
for 22k 24k
for 5k 7k 9k 10k 12k 13k 18k
10m
Piping length
Piping length
5m
7m
5m
7m
10m
20m
Additional amount No need
40g
100g
300g
Additional amount
120g
No need
900g
Outdoor unit
Indoor unit
A
A
A
Outdoor unit
Oil trap
Indoor unit
B
C
Outdoor unit
B
Indoor unit
B
for 5K 7K 9K 10K 12K 13K: B=5m
for 18K 22K 24K: B=10m
Max.Elevation:
Max. Length:
CAUTION
C
In case more than 5 metres,oil trap
for 5K 7K 9K 10K: A=7m
should be installed every 5~7m.
for 12K 13K:
A=10m
for 18K 22K 24K: A=20m
4
|