Haier Air Conditioner HPU 90CA03T3 User Manual

Cabinet unit  
Operation Manual  
CONTENTS  
HPU-90CA03T3  
Name of Parts  
1
(Cooling Unit)  
Parts and Functions  
Operation points  
Safety Precautions  
Operation  
2
3
4
5-6  
7
Users' Attention  
Maintenance  
8-9  
10  
Trouble shooting  
When problems occur  
When troubles occur  
Installation instruction  
Installation procedure  
Others  
11  
12  
13-14  
15-26  
27-28  
No.0150504455  
A
Parts and Functions  
6
7
TEMP  
TEMP  
FAN  
ON/OFF  
MODE  
2
1
8
5
4
3
1.Power ON/OFF Button  
Used for unit start or stop  
2.FAN Button  
Used to select fan speed:AUTO,LOW,MID,HIGH.  
3.TEMP Setting Button  
Used to set temperature. (Setting ranges: 16 C to 30 C)  
4.MODE Button  
Used to select operation mode: AUTO COOL DRY FAN HEAT  
5.Operation MODE Display  
Mode  
AUTO  
COOL  
DRY  
Panel  
FAN  
HEAT  
6.FAN SPEED Display  
AUTO(Flash) LOW  
MID  
HIGH  
7.LOCK State Display  
8.TEMPERATURE Display  
Used to display set temperature and room temperature.  
2
Operation points  
Anti-cold air blowing out  
Operation of air conditioner  
During Heating operation, after starting the  
unit, the indoor fan motor will not rotate  
When the ambient humidity is too high,  
in COOLING or DEHUMIDIFYING  
MODE  
F
AN  
SWING  
TEMP  
CLOCK  
SET  
TIMER  
SLEEP  
F
I
L
T
E
R
R
E
R
S
E
SET  
ON/OFF  
MODE  
F
A
N
SWING  
TEMP  
CLOCK  
SET  
TIMER  
SLEEP  
RESET  
FILTER RESET  
ON/OFF  
immediately to prevent cold air from blowing  
out.  
mode, there may be water dropped in the  
air outlet.  
?
Defrosting function  
3-minute protection function  
If start the unit immediately only During Heating operation, when frost formed on the  
after it is turned off, the compressor  
will start after 3 minutes have  
elapsed to protect the compressor.  
heat exchanger of outdoor unit, the air conditioner  
will defrost automatically for several minutes. During  
defrosting, both the fan of indoor and outdoor unit  
do not run. After finishing defrosting, the air  
conditioner will automatically resume operation.  
MODE  
F
A
N
SWING  
TEMP  
CLOCK  
SET  
TIMER  
SLEEP  
F
I
L
T
E
R
R
E
S
RESET  
ON/OFF  
Change of fan speed  
Hint  
When the air conditioner  
is in Heating mode, it  
absorbs heat from  
outside and release to  
indoors. So the outdoor  
temperature may affect  
the Heating effect.  
In COOLING mode, the air sending is set at AUTO,  
when the indoor temperature is near the set temperature,  
the fan speed will lower automatically.In HEATING  
mode, when room temperature reaches the set temperature,  
the compressor will stop running, and the fan will change  
to LOW FAN or stop.In DEHUMIDIFYING mode, the fan  
speed will change automatically.  
MODE  
F
A
N
SWING  
TEMP  
CLOCK  
SET  
TIMER  
SLEEP  
F
I
L
T
E
R
R
E
R
S
E
SET  
ON/OFF  
3
Safety Precautions  
Notice  
Do not put the fire  
devices in the places,  
which the air from  
the air conditioner  
can directly blow.  
Do not put or use any  
spray near the air  
conditioner, and do not  
directly spray to the air  
conditioner.  
The system should never be  
used for any other purposes  
than intended such as for  
preservation of food, flora  
and fauna, precision devices  
or work of art.  
It may cause the fire  
devices cannot burn  
completely.  
It may cause deterioration of  
the articles.  
Otherwise it may cause  
fire.  
Only use the proper specified fuse.  
Do not install the system where the air  
outlet may directly reach the flora and  
fauna.  
If use metal wire or copper wire to  
replace the fuse, it may cause trouble  
and fire accident.  
It will not be good for their health.  
Do not use the pow-  
er switch to turn on  
or off the air condit-  
ioner.  
When operating the system sim-  
When cleaning, please  
stop the unit and cut o-  
ff the power first.  
Do not perform  
cleaning, when the  
indoor fan motor is  
rotating in high  
speed.  
ultaneously with a combustion  
apparatus, indoor air must be v-  
entilated frequently.*  
ON  
OFF  
It may cause fire or  
Creepage.  
Insufficient ventilation may ca-  
use the danger of lack of oxygen.  
Do not use such equipment as a water heater,  
etc., around the indoor unit  
or the wire controller.  
Do not put the water containers,  
such as vase, on the unit.  
If the water enters  
If the system is operated at the vicinity of such  
equipment that generates steam, condensed  
water may drip during cooling operation or it  
may cause Creepage or short-circuit.  
into the unit and damages  
the electric insulation material,  
it may cause electric shock.  
Safety precautions when moving, reinstalling and repairing the air conditioner  
Warning  
Do not refit the air conditioner.  
When repair is needed, please  
contact your dealer.  
When moving the air conditioner to another  
installation place, please contact the dealer  
or the professional installer.  
Improper repair may  
cause water leakage,  
Improper moving and reinstallation may cause  
water leakage, electric shock and fire accident.  
electric shock and fire accident.  
Applicable ambient temperature range:  
Maximum:  
Minimum:  
32 / 23  
18 / 14  
D.B / W.B  
D.B / W.B  
Indoor  
Cooling  
Maximum:  
Minimum:  
D.B / W.B  
D.B  
52 / 32  
21  
Outdoor  
4
Operation  
AUTO, COOL , HEAT and DRY Operation  
LOCK  
TEMP  
TEMP  
FAN  
ON/OFF  
MODE  
5
4
1. Unit start  
Press ON/OFF button,unit starts.  
Previous operation status appears on LCD (except for TIMER,SLEEP and SWING setting)  
2.Select operation mode  
Press MODE button. At each press, operation mode changes as follows:  
AUTO  
COOL  
DRY HEAT  
FAN  
Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation  
or select FAN operation  
3.Temperature setting  
Press TEMP button.  
Every time the button is pressed, temp. setting increases 1 C; if the button is kept pressed, temp. setting will  
increase quickly.  
Every time the button is pressed, temp. setting decreases 1 C, if the button is kept pressed, temp. setting will  
decrease quickly.  
Set proper temperature  
4.Adjust FAN button  
Press FAN button. At each press, fan speed changes as follows:  
COOL operation starts  
when room temp.is  
higher than temp.  
setting.  
Ultra-low air flow  
AUTO(Flash)  
MID  
HIGH  
LOW  
Temp. setting +2 C  
Temp.setting  
Air conditioner will run at the selected fan speed.  
On reaching temp.setting  
+2 C, unit will run in mild  
DRY mode.  
5. Unit stop  
Press ON/OFF button,unit stops.  
In FAN mode, the temperature setting is not displayed on LCD,and "Auto Fan" not available.  
In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit will run intermittently  
at LOW speed regardless of FAN setting. When room temperature is lower than temperature setting, unit will  
only run FAN operation.  
In HEAT mode,warm air will blow out after a short period of time due to cold-draft prevention function.  
In Auto mode,unit will adjust fan speed according to room temperature automatically.  
5
Operation  
Fan Operation  
LOCK  
TEMP  
TEMP  
FAN  
ON/OFF  
MODE  
4
1.Unit start  
Press ON/OFF button to start your air conditioner.  
Previous operation status appears on LCD (except for TIMER, SLEEP, and SWING setting).  
2.Select operating mode  
Press MODE button. At each press, operation mode changes as follows:  
AUTO  
COOL  
DRY HEAT  
FAN  
Then select FAN  
3. Adjust fan speed  
Press FAN button. At each press, fan speed changes as follows:  
Air conditioner will run at the selected fan speed.  
4. Unit stop  
Press ON/OFF button to stop unit.  
About FAN mode  
When the air conditioner runs in FAN mode, it is not possible to select  
AUTO FAN or to set temperature.  
5.  
Warning:cooling only types are not with functions in heating mode.  
6
Users’ Attention  
If do not use the air conditioner  
for a long time, it is necessary to  
cut off power.  
Do not press tightly with the LCD part of  
the wire controller to avoid damage of it.  
Set proper room temperature  
If do not cut  
Cut off  
Not too low or high and make every peop-  
power  
off power, the  
unit may consume  
le in the  
Heating is  
18~23¡  
room  
Cooling is  
power. In order to protect the unit,  
before using the air conditioner  
again, turning on the power at least  
12 hours in advance.  
The windows should be hung  
with curtains or blinds.  
Do not let the sun  
26~28¡  
feel  
comfortable.  
Do not let the cold air blows directly to  
human body for a long time and do not  
make the room temperature drop too  
low.  
Otherwise, it may  
shine directly shine  
in the room; do not  
let the outdoor air  
cause uncomfortable  
or bad to your health.  
The airflow cannot directly blow  
to the pets and plants.  
Otherwise, pets  
enter room.  
The articles must keep dry cannot  
be put under the indoor unit.  
When the humidity  
and plants  
may be hurt.  
The room should often ventilate.  
After a long-time  
of using air  
conditioner, the  
room must be  
ventilated.  
is over 80% or  
the drainage  
outlet is blocked,  
the indoor unit may drop water.  
Do not put articles around the  
air inlet and outlet.  
This kind of obstacle can lower the  
efficiency of the air conditioner or  
cause unit trouble.  
Do not keep the doors and windows  
open  
Otherwise, it  
may lower the  
efficiency of  
the air conditioner.  
Television, radio and acoustics, etc.  
equipment should keep over 1m from  
indoor unit and wire controller.  
Otherwise, they may  
disturb the image  
The air conditioner can only be used  
in air conditioning. It can not be  
used in other purpose.  
Do not use the air conditioner in some  
specific purpose, such as storage or  
protect food, animals, plants, precise  
instrument and  
and cause noise.  
Do not put any drying  
artwork,  
devices under  
otherwise,  
the indoor unit.  
the quality  
The heat may cause  
of them may  
the deformation of  
be declined.  
indoor unit.  
7
Maintenance  
Disconnect power supply  
Don't touch it with wet  
hand  
Don't wash with hot water  
or solvent to clean the unit  
Remove air inlet grille  
First cut off the power supply, then turn  
the embedded part of air inlet grille  
upwards, finally use cross-shaped  
screwdriver to screw off the screw.  
Air filter cleaning  
Use water or vacuum cleaner to clean it.  
If it is extremely dirty, wash it with  
neutral detergent or soap water.  
Wash it with clean water and install  
it after complete dry.  
Caution:  
Don't use hot water over 40 C,  
as this may cause damage to air filter.  
Wipe air filter carefully.  
40¡  
Indoor and outdoor cleaning  
Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with  
clean and soft cloth.  
If air conditioner is very dirty, clean it with cloth  
soaked in neutral detergent,then wipe off the  
detergent with clean water.  
Don't use water higher than 40 C , which will cause  
discoloring and deformation.  
Don't use insecticide or other chemical detergents.  
40¡  
8
Maintenance  
After season maintenance  
Let the unit run in Fan mode for half a day in a  
fine weather to dry completely the unit inside.  
Turn off the unit and pull out power plug.  
There might be certain power consumption even  
if unit is stopped.  
Clean air filter and indoor unit, cover outdoor  
unit after cleaning.  
Before season maintenance  
Check if there are obstacles at inlet  
and outlet of indoor and outdoor unit,  
whick will reduce unit efficiency.  
Don't fail to attach air filter after making sure it is cleaned.  
Dust will enter into unit causing damages or faults if it is running without air filter.  
To protect compressor at start, please connect  
external power supply to the unit 12 hrs prior  
to starting. Also please keep the power supply  
switch ON during the whole season.  
9
Trouble shooting  
Followings are not problems  
During unit start and operation or at stop, a swishing or  
gurgling noise may be heard. This noise is generated by  
refrigerant flowing in the system.  
Sound of water flowings are not  
problems.  
During unit operation, a cracking noise may be heard.  
This noise is generated by the casing expanding or  
shrinking because of temperatuer changes.  
Sound of cracking is heard.  
Smells are generated.  
This is because the system circulates smells from the  
interior air such as the smell of cigarettes or the painting  
on the unit.  
During operation, white fog or steam  
comes out of indoor unit.  
When unit is running at places like restaurant where dense  
edible oil fumeis always exist, this will happen.  
To prevent frost from accumulating on indoor heat  
exchanger, unit will switch to fan operation for a while  
then resume cooling operation.  
In cooling operation, unit switches to fan  
operation.  
Unit will not restart after stop.  
Won't start?  
Though ON/OFF button is set to  
ON, unit won't resume cooling,dry  
or heating operation in 3 min after  
it is stopped, this is because of 3-  
min-delay protection circuit.  
Please wait 3 minutes  
No outlet air or fan speed can't be changed in  
dry mode.  
Unit will reduce fan speed repeatedly and automatically  
if room temp. is too low in dry operation.  
In heating operation, water or  
steam are blown out of indoor  
unit.  
This occurs when frost  
accumulated on the outdoor unit  
is removed.  
(during defrosting operation)  
In heating operation, indoor fan won't stop even After unit stops, indoor fan will go on running until indoor  
unit cools down.  
if unit is stopped.  
10  
When problems occur?  
Before ask for services, please first check your unit against following.  
Air conditioner won't start.  
Is city power supply normal?  
Is leakage current breaker  
activated?  
Is power supply switch  
turned on?  
This is very dangerous, please  
disconnect power supply  
immediately and contact your  
dealer.  
Power  
failure?  
Power supply  
switch is not set  
at ON.  
Poor cooling or heating  
Are there any obstacles at inlet  
or outlet grill?  
Are operation controlls  
adjusted correctly  
as specified?  
Is air filter too dirty?  
Proper  
temp  
Are horizontal louvers  
at up position (in  
heating mode)?  
Any doors or windows left  
open?  
Poor cooling  
If there are unexpected heat  
sources in the room?  
Too many people in the room?  
Is there any direct sunlight  
in the room?  
If your unit still can't work properly after above mentioned checks, or following problems occur,  
please stop it immediately and contact your dealer.  
Fuses or circuit breakers often blow out.  
Water comes out in cooling/dry operation.  
Operation is abnormal or sound is heard.  
If the fuse on PC board is broken please change it with the type of T.6.3A/250VAC.  
11  
When Troubles Occur ?  
Find the following troubles occur, please stop the unit and cut off power, then  
contact the after-sales service worker.  
Warning  
If finding any abnormal phenomena (e.g. smell of burnt), please cut off power and ask help for after-sales  
service personnel.  
If still use the air conditioner under this condition, the unit may be damaged and maybe cause electric shock  
or fire, etc. accidents.  
After taking the following measure,  
please contact the commissioned  
service center.  
Symptom  
Cut off power  
The fuse and creepage breaker are often blown out;  
or the operation switch works abnormally.  
In Cooling or Dehumidifying operation, there is  
water leakage;  
Cut off power and inform your  
commissioned service center.  
Malfunction  
Error display  
Failure description  
Code on wired controller  
Room temp. sensor abnormal  
Indoor coil temp. sensor abnormal  
Outdoor temp. sensor abnormal  
E1  
E2  
E3  
Outdoor coil temp. sensor abnormal or compressor discharge  
temperature protection abnormal  
E4  
Over-current malfunction  
E5  
E6  
E8  
E9  
High / Low pressureabnormal  
Communication malfunction between indoor PCB and wired controller  
Communication malfunction between indoor PCB and outdoor PCB  
The float switch malfunction  
E0  
12  
Installation instruction  
Before installing, do read this “Safety precautions” carefully to guarantee the proper installation.  
The below attentive matters are divided into “ Warning” and “ Note” two parts. When the wrong  
installation occur, it is very possible death and severe injury and other serious accidents will happen. For  
those items are listed in “ Warning” part. But even the items listed in “ Note” part can also cause serious  
accidents. Above all, both the two parts are very important contents related to safety, so they must be obeyed.  
After finishing the installation work, do test run to verify everything is normal. After that please explain the  
using and maintenance methods to the user. Additionally, give this installation manual and operation manual  
to the user and ask them to keep it properly.  
The commissioned repair center shall do the installation work. If you do the installation work by yourself,  
the improper installation will cause water leakage, electric shock fire and other accidents.  
The installation work shall be in line with what the installation manual specified. If installation is not  
proper, water leakage, electric shock, fire and other accidents will occur.  
Install the air conditioner to a place where can definitely stand its weight. The air conditioner can not be  
installed on a nonmetal bracket (such as theft guard net). Places not firm enough will cause drop down of  
unit resulting in body hurt.  
The installation work shall be preventive to typhoon and earthquake. If the installation work is not met  
with the requirements, overturn of the unit will occur resulting in accidents.  
Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part  
of the terminals to prevent it from the external force. Improper connection and fixing will cause heating  
and fire etc. accidents.  
Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the  
external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents.  
When setting or moving the air conditioner do not let the air and things alike get into the refrigeration  
system except the specified refrigerant (R22). If air and other things enter, abnormal high pressure will  
occur, which easily cause break and body injuries etc. accidents.  
When installing, do use the accessories or specified parts. If not using the parts specified by our company,  
water leakage, electric shock, fire and refrigerant leakage will occur.  
Do not lead the drain hose to drain where the sulfur gas may be involved. Otherwise, the poisonous gas  
will enter into the indoor.  
During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the  
refrigerant gas meets fire, poisonous gas will be produce.  
After installation, confirm there is no leakage of refrigerant. If the refrigerant gas enters into room and  
meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced.  
Do not install the unit in a place where the combustible gas may be leaked. In any case the combustible gas  
leaks and accumulated around the unit, fire accident will occur.  
The drain hose should be correctly installed according to the installation manual to ensure smooth drainage,  
and take proper heat preservation measure to prevent from dew. Improper pipe installation may cause water  
leakage result in wet the indoor articles.  
Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation.  
If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet  
the floor and indoor articles.  
Do grounding work. Do not connect the grounding wire to gas pipe, tap, lighting rod or telephone line.  
Improper grounding will cause electric shock.  
In some places the creepage breaker shall be installed. If do not install the breaker, electric shock may occur.  
After electric installation, power on them to do electric leakage test.  
13  
Installation instruction  
Notice  
This manual can not include all kinds of conditions, if you have new  
requirements and questions, please contact with local Haier Sales Center.  
Warning  
Before installing the unit, please read this manual carefully. Improper  
installation may cause accidents and make unit damage or death.  
Installation tools  
1. Screw driver  
2. Hacksaw  
3. 70mm dia. hole core drill  
5. Spanner (14, 17, 27mm)  
7. Flaring tool  
4. Spanner (dia. 17, 27mm)  
6. Pipe cutter  
8. Knife  
9. Nipper  
11. Measuring tape  
13. Refrigerant oil  
10. Gas leakage detector or soap water  
12. Reamer  
14. Lead-solder tool  
Standard accessories  
Following parts shall be field  
supplied  
Parts name  
Adhesive tape  
Pipe clip  
Mark  
A
B
C
Connecting hose  
Drain hose  
D
E
Insulation material  
Putty  
F
14  
Installation procedure  
1. Before installation  
[Before finishing installation, do not throw the attached installation parts away.]  
Confirm the route to carry the units to the installation place.  
Do not remove the package of the unit, before carrying it to the installation place.  
When have to remove the package, use a soft material or protection board with rope to lift  
the unit to prevent the unit from damage or bumping scrape.  
2. Selection of installation place  
Select the firm place that will not influenced by vibration and can bear the weight of the unit  
Select the place with easy drainage and place can perform outdoor unit pipe connecting.  
Select the place far away from heat source, vapor source and direct sunshine to avoid the  
causing of the trouble in operation parts and the deformation of the casing.  
Select the place where the cool air or warm air can evenly spread to every corner of the room.  
Select the place near power receptacle leaving sufficient space around the unit. (Referring to  
installation diagram)  
Avoid the following installation places  
Place with oil fog splash and much vapor (e.g. mechanical plant and kitchen, etc.) to prevent  
heat exchanger from performance lowering and plastic parts from corroding to damage.  
Place may generate or keep corrosive gas (sulfur dioxide, etc.), flammable gas (diluent, gasoline,  
etc.) to prevent heat exchanger from corroding, plastic parts from damage and flammable gas from  
causing fire accident.  
Hospital, etc. places near the machine generates electromagnetic wave or high frequency signal to  
prevent the mixed wave from causing wrong action of the control parts.  
Place can be blown by the sea wind (coastal area) to prevent the casing and heat exchanger from  
corroding.  
3. Installation space  
(Indoor unit) please keep the spaces larger than the following dimension.  
Unit (mm)  
1000  
50  
600  
600  
15  
Installation procedure  
indoor unit  
Installation of indoor unit  
Selection of installation place  
Place where it is easy to route drainage pipe and outdoor piping.  
Place away from heat source and with less direct sunlight.  
Place where cool and warm air could be delivered evenly to every corner of the room.  
Place near power supply socket. Leave enough space around the unit (refer to installation  
drawings).  
Fixing of the unit  
Position of the wall hole  
1.  
Wall hole should be decided according to installtion place and piping direction. (refer  
to installation drawings)  
Making a wall hole  
2.  
Drill a hole of 70mm dia. with a little slope towards outside.  
Install piping hole cover and seal it with putty after installation.  
INDOOR  
OUTDOOR UNIT  
wall thinkness  
wall hole  
70mm  
( Cross section of wall hole )  
Fixing of indoor unit  
To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and  
L-shaped metal at floor.  
Self-tapping  
screw  
all-prevention fitting metal (accessory)  
Wood screw  
Please install the whole  
unit horizontally,with a slop  
of 1 degree at front and  
rear,left and right.  
L-shaped metal  
(accessory)  
16  
Installation procedure  
indoor unit  
Installation of fall-prevention fitting metal:  
Fix the fitting metal to the wall by screws so that there is no clearance between them.  
With the unit set up vertically, fix the fitting metal to the unit with screws while making an  
adjustment at the long portion of the hole so that there is no clearance between the upper surface  
and the fitting metal.  
Installation of L-shaped metal  
Fix to the unit by screws so that there is no clearance between the fitting metal and the unit.  
After confirming that the unit has been set up vertically to the floor, fix it to the floor by bolt.  
Piping connection  
Connecting method  
1.  
Apply refrigerant oil at half union and flare nut.  
To bend a pipe, give the roundness as large as possible not to crash the pipe.  
When connecting pipe, hold the pipe centre to centre then screw nut on by hand,refer to Fig.  
Be careful not to let sundries, such as sands enter the pipe.  
Forced fastening without centering may  
damage the threads and cause a gas leakage.  
Pipe dia  
Fastening torque  
.
42N m  
Liquid pipe 12.7mm(1/2")  
17  
Installation procedure  
Indoor unit  
2. Piping connection of indoor unit  
Arrangement of piping and drainage pipe  
After opening inlet grill, you will see a control  
box as shown in the Fig.  
Remove the cover before working.  
Cut away, with a hammer or a saw, the lid for piping according to piping direction.  
Insulation material  
Drain hose  
Connecting electric cable  
for indoor and outdoor unit  
Copper tube  
According to the piping method, connect the piping on indoor unit with union of connecting pipe.  
Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping  
together with polyethylene tape.  
Insert the bound piping connecting electric cable and drain hose through wall hole to connect with  
outdoor unit.  
Arrangement of drain hose  
Drain hose shall be placed in under place.  
There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.  
Indoor unit  
Up  
Down  
Bad  
Slope  
Good  
If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with  
insulation material.  
18  
Installation procedure  
Indoor unit  
Main points of installation refrigerant pipe  
Please install the gas pipe and liquid pipe according to the following shown method.  
Please remove the cover piece on the gas pipe and the screw cap on the liquid pipe.  
A
B
¢ Please connect the connecting pipes between indoor and outdoor unit according to the  
following method.  
a) When introducing the pipe from right side  
Use attached accessory <A> to connect the on-the-spot connecting pipe and gas  
pipe.  
A B  
b) When introducing pipe from rear side or left side  
Use attached accessory <A> to connect the on-the-spot connecting pipe and gas  
pipe.  
¢ After finishing connection of connecting pipe, please do thermal insulation treatment  
by using the attached thermal insulation material. Otherwise, it may cause water  
leakage.  
19  
Installation procedure  
Outdoor unit  
Outdoor unit  
1.GENERAL  
They can be mounted on a slab or rooftop. It is important to consult your local  
code authorities at the time the first installation is made.  
Check following points before attempting any installation:  
Structural strength of supporting members.  
Clearances and provision for servicing.  
Power supply and wiring.  
Location for minimum noise, where operating sounds will not disturb owner or  
neighbors.  
Location where there is no risk of combustible gas leakage.  
Location where external water drainage cannot collect around the unit.  
Location where roof runoff water does not pour directly on the unit. Provide  
gutter or other shielding at roof level. Don't locate unit in an area where excessive  
snow drifting may occur or accumulate.  
Provide a level concrete slab. To prevent transmission of noise or vibration, slab should  
not be connected to building structure. Some sort of sound-absorbing material should be  
placed between the condenser and the slab. A good material to use is rubber and cork pad.  
For rooftop application, make sure the building construction can support the weight  
and that proper consideration is given to the weather-tight integrity of the roof. The  
condensing unit contains moving parts and can vibrate. Therefore, sound is also a  
consideration in rooftop applications.  
! WARNING - Install the unit securely in a place that can bear the weight of the unit.  
When installed in an insufficiently strong place, the unit could fall causing injury.  
20  
Installation procedure  
Outdoor unit  
2.UNIT CLEARANCES  
10" Min.  
Service Access  
18" Min.  
10 "Min.  
Service Access  
18 Min.  
10"  
"
"
10  
Figure 1  
The minimum clearances for the unit are illustrated in Figure 1. Condenser air enters from  
three sides. Air discharges upward from the top of the unit. Refrigerant tube and electrical  
connections are made from the service access area. The most common application will  
find the unit best located about 10" from back wall with connection side facing the wall.  
This application minimizes exposed tubing and wiring, minimizing the space for  
youngsters to run around the unit with subsequent damage to the tubing or wiring.  
In more confined application spaces, such as corners provide a minimum of 10" clearance  
on all air inlet sides. For service access to the compressor and control box, allow 18"  
minimum clearance. Ensure top is unobstructed. If units are to be located under an  
overhang, there should be a minimum of 36" clearance and provision made to deflect  
the warm discharge air out from the overhang.  
In order to have an unrestricted air flow, owners should be advised to avoid lawn mower  
discharge toward the unit depositing debris on the fin coil surface reducing the unit  
efficiency.  
.3.REFRIGERANT PIPING  
The refrigerant piping is very important as it affects the proper operation and efficiency  
of the air conditioning system. Note the following guidelines:  
OUTDOOR UNIT  
ADDITIONAL SUCTION LINE  
OIL TRAP FOR EACH 20 FOOT  
PITCH SUCTION LINE TOWARD OUTDOOR  
UNIT 1/2" FOR EVERY 10' OF LINE  
RISE OF PIPE  
INDOOR UNIT ABOVE OR  
LEVEL TO OUTDOOR UNIT  
30m  
LIQUID LINE  
SUCTION LINE OIL  
TRAP WHEN INDOOR  
UNIT IS 4 FEET OR  
MAX.  
INDOOR UNIT  
OUTDOOR UNIT  
M O R E  
B E L O W  
OUTDOOR UNIT  
INDOOR UNIT  
LIQUID LINE  
INDOOR UNIT BELOW OUTDOOR UNIT  
6'  
A
B-1  
INVERTED LOOP  
LIQUID LINE  
INDOOR UNIT  
SUCTION LINE  
30m  
OUTDOOR UNIT  
MAX.  
B-2  
21  
Installation procedure  
Outdoor unit  
Only refrigeration-grade copper piping (dehydrated and sealed) should be used. Take extreme  
care to keep the refrigerant tubing clean and dry prior to and during installation.  
If in doubt, blow out the tubing with dry nitrogen to remove any chips or debris before  
connection. Always keep tubing sealed until it is in place and the connections are to be made.  
Refrigerant piping should be as short as possible, with a minimum of elbows or bends, to avoid  
capacity loss and increased operating costs.  
Refrigerant lines must be adequately supported. If metal strapping is used to secure the tubing,  
do not allow the strapping to directly contact the tubing. Use a closed cell insulation to separate  
the strapping from the tubing.  
Do not kink or twist the tubing.  
Refrigerant piping should not be installed in a cement slab, as this limits access to the  
refrigerant should a leak be suspected.  
To ensure good oil return to the compressor, it is important to pitch the horizontal suction  
line toward the compressor, approximately 1/2" for every 10' of line.  
The maximum connection pipe is 50m ,the maximum drop different between indoor unit and  
outdoor unit is 30 m  
Line Insulation  
Suction line requires insulation in order to prevent condensation from forming on the  
piping and to prevent heat gain caused by surrounding air. Generally 3/8" wall thickness  
of Armflex or equivalent is satisfactory. In severe application (hot, high humidity areas)  
greater thickness may be required. Apply the line insulation by sliding it on the sealed  
tuing before cutting and making connections.  
Liquid line does not necessarily need insulation, however, if they are exposed to high  
ambient temperatures (i.e. kitchen, boiler rooms, hot attics & rooftop surface), then,  
they should be insulated. Make sure to use the proper size tubing for the liquid line to  
prevent liquid refrigerant flashing to a vapor within the liquid line.  
Do not allow the vapor line and liquid line to touch together. This would cause an  
undesirable heat transfer resulting in capacity loss and increased power consumption.  
Tubing connection  
! CAUTION - Use extreme caution in removing the caps from the suction and liquid line  
fittings, as there is pressure present. A fitting is on the liquid line to remove pressure.  
! CAUTION - Condensing units are charged with refrigerant. Condensing unit liquid  
and suction valves are closed to contain the charge within the unit. Do not force the valve  
stem against the retaining ring. If the valve stem is backed out past the retaining ring,  
system pressure could force the valve stem out of the valve body and possibly cause  
personal injury.  
22  
Installation procedure  
Outdoor unit  
Matters needing attention  
Never use oxygen,flamable and poisonous gases for the leak test.  
High-pressure  
gauge  
Low-pressure  
gauge  
Three-way valve fully  
closed(gas side)  
VL VH  
Indoor  
Outdoor  
Gauge distributor  
Solder joint  
Solder joint  
Access hole  
Access hole  
6.4  
Copper  
pipe  
Tightly  
closed  
Solder  
joint  
Relief valve  
6.4  
Copper pipe  
Indoor unit  
Outdoor unit  
Three-way valve fully closed  
liquid side  
Detailed diagram of the  
three-way valve  
To the gauge  
distributor  
(Gas side)three-way valve  
(Liquid side)three-way valve  
(Gas side )  
access hole  
To the unit  
(Liquid side)access hole  
To the unit  
Field tube  
installation  
Field tube  
installation  
2
Step 1:Charge for more than 3 minutes under 0.3MPa(3.0kg/cm g)  
2
Step 2:Charge for more than 3 minutes under 1.5MPa(15kg/cm g)  
--Serious leakage may be found.  
2
Step 3:Charge for more than 24 hours under 3.0MPa(30kg/cm g)  
--Small leakage may be found.  
Check for pressure decrease  
Without pressure decrease-Pass  
With pressure decrease-Check for leakge.  
There will be a 0.01MPa(0.1kg/cm2g) pressure change for every 1 C ambient temperature change during  
the 24-hour pressure charge.It should be corrected during the test.  
23  
Installation procedure  
Outdoor unit  
Check for leakage  
In the case of pressure decrease during steps 1 to 3 ,check the joints with the ear,hand or soapsuds for  
leakage.Repair it by welding or tighten the connecting nut up.  
Vacuum Pumping  
Use vacuum pump to evacuate the air.Never use the refrigerant for the evacuation.  
Drain off the nitrogen gas after the leak test and then connect the vacuum pump as shown in the figure  
below.  
The vacuum pumping must be done from both the liquid and gas inlets.  
High-pressure  
Low-pressure  
gauge  
gauge  
Three-way valve fully  
closed(gas side)  
VL VH  
Indoor  
Outdoor  
Gauge distributor  
Solder joint  
Solder joint  
Access hole  
Access hole  
6.4  
Copper  
pipe  
Tightly  
closed  
Solder  
joint  
Relief valve  
6.4  
Copper pipe  
Indoor unit  
Outdoor unit  
Three-way valve fully closed  
liquid side  
Detailed diagram of the  
three-way valve  
To the gauge  
distributor  
(Gas side)three-way valve  
(Liquid side)three-way valve  
To the unit  
(Gas side )  
access hole  
(Liquid side)access hole  
To the unit  
Field tube  
installation  
Field tube  
installation  
Use a vacuum pump with high degree of vacuum(below-755mmHg) and large volume displacement  
(above 40L/min)  
The pumping time depends on the length of the connecting pipe.Generally,it takes about 2-3 hours.  
Make sure that the Y-shaped valves on both the gas and liquid sides are closed before pumping.  
If the vacuum can no reach-755mmHg within 2 hours,continue pumping for another 1 hour.  
If the vacuum can no reach-755mmHg after more than 2 hour's pumping,close the valves VL and VH  
onthe gauge distributor and stop pumping.One hour later,check the vacuum again.If the vacuum has  
changed,it means there is a leakage.Repair it.  
After the above steps,replace the vacuum pump with the refrigerant pump and refill refrigerant.  
24  
Installation procedure  
Outdoor unit  
Adding refrigerant  
Containers for R22 refrigerant must be marked  
Refrigrant must be added in liquid state.  
Refrigerant bottle swith or without a siphon  
tube can be refilled with refrigerant upright  
or upside down,Respectively.  
with R22  
R22 refrigerant cannot share the same  
instrument distributor and filling pipes.  
Refrigerant charge  
After finished vacuum the system,charge the vacuum to the refrigerant pump,chargeing the refrigerant.  
Calculation of the refrigerant charge  
Note:when unit shipping out of the factory,charge the refrigerant not including the connstruction  
procedure charged parts.  
The calculation of the refrigerant charging:  
When the connection pipe(L)<=5 meters, not need to add refrigerant;If the connection pipe  
(L)> 5 meters,we need recharge the 60g refrigerant per add 1 meter.  
That is :the quantity of refrigerant charging=(L-5)*60(g)  
Refill refrigerant  
When the outdoor valve is shut,fill the refrigerant from the access hole at the gas and liquid sides.  
If the required filling is impossible,open all the gas and liquid valves,then slightly shut the gas valve,  
run the compressor and fill the refrigerant from the access hole at the gas side.Now adjust the gas  
valve to control the refrigerant flow,which will be gasified during absorption by the system.  
If there is insufficient refrigerant in the system caused by leaks,refill it after the remaining refrigerant  
is recollected.  
Open all valves  
Open all the valves of the outdoor unit.  
Heat isolation of the pipes  
Separate isolation should be made for the liquid and gas pipes.  
Materials used for the pipe isolation at the gas side must withstand above 120 C temperature.  
25  
Installation procedure  
Note:  
All the wires should be copper core wires.  
Electric wiring  
The power cable of indoor unit should be equipped according to the operation manua of indoor unit.  
Before finishing vacuumizing the refrigerant pipe system, do not supply power to indoor unit.  
When connecting the indoor & outdoor wire, check the number of the indoor & outdoor terminals,  
the terminals with the same number connected together with one wire.  
Incorrect wiring will damage the controller of the air conditioner or make the unit work abnormally.  
The air conditioner must use special power circuit and special air switch (40A), groundign wire. The  
wiring work should be done by a qualified electrician according to the national wiring rule.  
The creepage breaker must be installed. The grounding line and the neutral line of the receptacle  
must be strictly separated. It is incorrect to connect the neutral line with the grounding line.  
The connection type of power cord is Y connection. If the soft power cord is damaged, to avoid  
risk, it must be replaced by the manufacturer or their specific repair department or similar professional  
worker.  
Wiring method  
1.The wiring method of orbicular terminal  
For the connection wire which end is orbicularterminal,  
its wiring method is as the right figure shown.  
Dismantle the screw and put it through the ring at the end  
of the connection wire, then connect it to the terminal block  
and tighten the screw.  
The wiring method of orbicular terminal  
Wrong pressing  
Correct pressing  
2.The wiring method of straight terminal For those  
connection wires whose end are not orbicular terminals,  
their wiring method is: Loosen the connecting screw,  
insert the end of the wire directly into the terminal block,  
and then tighten screw. Pull the wire outwards slightly  
to confirm it is held tightly.  
Terminal block  
Wire holding clamp  
(Sketch map)  
Y/G  
Terminal block of  
indoor unit  
3.Pressing method of connection wire:  
After wiring, the connection wire must be pressed with  
wire holding clamp. The wire holding clamp should press  
on the out cover of the connection wire. As the right  
figure shown:  
Connect wire between indoor & outdoor unit  
As the wiring diagram show to arrange the connection  
wire.  
Power supply:  
380-400V~,3N,50Hz  
2
3
1
N
L1 L2 L3  
Y/G  
2
3
1
Terminal block of  
outdoor unit  
Terminal block of  
outdoor unit  
The power cable and connecting cable are self-  
2
provided. The power cable shoule be 5x6.0mm ;  
2
the connecting cable should be 4x1.0mm .  
Note: The terminal block's mark at the two ends of the  
connection wire should be corresponding one by one,  
otherwise the air conditioner cannot work normally.  
Selection of size of power supply and interconnecting wires.  
Circuit breaker  
Item  
Earth leakage breaker  
Power source  
wire size  
(minimum)  
Switch breaker  
(A)  
Switch  
breaker  
Leak  
current  
Overcurrent protector  
rated capacity (A)  
Phase  
Model  
6.0mm2  
40  
30mA  
HPU-90CA03T3  
3
30  
40  
26  
Others  
1. Power supply  
The parameter of power cord is over 2.5mm2.  
Air conditioner must use an exclusive line (over 30A)  
When installation air conditioner in a wet place, try to use a circuit breaker against  
Current leakage.  
For installation in other places, use circuit breaker as far as possible.  
The breaker of the air conditioner should be all-pole switch ; and the distance between  
its two contacts should be no less 3 mm.  
Such means for disconnection must be incorporation in the fixed wiring  
2. Pipe cutting and flaring  
Be sure to carry out deburring after pipe cutting with a pipe cutter.  
Insert flaring tool to make a flare.  
Pipe dia.  
Dimension A(mm)  
1.2 ~ 2.0  
A
Flaring tool  
Liquid pipe  
12.7mm (1/2")  
Correct  
Incorrect  
Lean Damaged flare Crack  
Partial Too outside  
Installation inspection and test run:  
Please operate unit according to this Manual.  
Items to be checked during test run. Please made a " "in " "  
Are there any gas leakage?  
How is insulation at piping connection carried out?  
Are electric wires of indoor and outdoor unit firmly inserted into terminal block?  
Is electric wiring of indoor and outdoor securely fixed?  
Is drainage securely carried out?  
Is earth line ( grounding ) securely connected?  
Is power supply voltage abided by the code?  
Is there any noise?  
Is control display normal?  
Is cooling operation normal?  
Is room temp. regulator normal?  
27  
Others  
1.Calculation of refrigerant density  
Calculation will be made according to the following methods:  
1) Total refrigerant content of each system (kg) =content of 1 outdoor system + refilled refrigerant  
Content of 1 outdoor system:Factory filled refrigerant  
Refilled refrigerant:Filled content during installation according to the diameter and length of the  
liquid piping.  
3
2) Calculation of the minimum room space (m ).  
3) Calculation of refrigerant density  
Total refrigerant content  
3
Refrigerant density:0.3(kg/m )  
Minimum room space  
2.Preventive measures against excess of critical value  
1) Make ventilation holes  
Ventilation holes should be built above and under the door.The area of each hole should not be smaller  
than 0.15% of the room space.Holes can be made directly in the wall.  
2) Reduce the filling content of refrigerant  
Filling content of refrigerant can be reduced by shortening the distance between the indoor and  
outdoor units.  
By reducing the capacity of the outdoor unit.  
When outdoor unit be made up of several units.the outdoor capacity of each system should reduce.So  
the refrigerant content of system reduce.  
3) Install ventilation fans.  
Users can install uninterrupted ventilation fans to keep the refrigerant density under the critical value.  
If uninterrupted ventilation is impossible,a combined fanning and alarming device should be installed  
in its stead (through which immediate ventilation is possible when leak occurs).  
(See the figure below)  
An example  
Ventilation fan and gas leak alariming device  
Vertilation opening  
The gas leak alarming  
device should be installed  
at refrigerant gas  
stagnation areas  
28  

AllerAir 8000 D Vocarb User Manual
Burley BABY CARE SCD589 User Manual
Bushnell Battery Charger PP1085 User Manual
Canon PIXMA MP490 Multifunction Photo Printer MP490 User Manual
Carrier KH_123P User Manual
Danby DESIGNER DAC9003D User Manual
Friedrich KUHL R 410A User Manual
Fujitsu Air Conditioner R410A User Manual
Haier Air Conditioner HPU 48HK03 User Manual
HP Hewlett Packard All in One Printer C9309A User Manual