Haier Air Conditioner AS12GS1ERA User Manual

SPLIT TYPE ROOM AIR CONDITIONER  
OPERATION MANUAL  
HSU-09CK3W3N  
HSU-09CK6G2N  
HSU-09CK6B2N  
HSU-12CK3W3N  
HSU-12CKCS3N  
HSU-12CK6G2N  
HSU-12CK6B2N  
HSU-12CKAG3N  
HSU-12CKAB3N  
HSU-18CK3W3N  
HSU-18CK6B2N  
HSU-18CK6G2N  
HSU-18CKBS3N  
HSU-15CKBS5N  
HSU-18CKBS5N  
HSU-18CKAB3N  
HSU-18CKAG3N  
HSU-15CKAG5N  
HSU-18CKCS3N  
HSU-24CK6B2N  
HSU-13CXAS5N  
HSU-13CXAS3N  
HSU-13CXAR3N  
HSU-13CXBW3N  
HSU-19CXBW5N  
HSU-24CXAS3N  
HSU-19CXAS5N  
HSU-19CXAS3N  
HSU-09LEK03-Y3  
HSU-12LEK03-Y3  
HSU-18LEK03-Y3  
HSU-24LEK03-Y2  
HSU-09LEK03/R2(DB)  
HSU-24LEK03/R2(DB)  
HSU-10LIN13  
HSU-09LTS14  
HSU-12LTS14  
HSU-18LTS14  
HSU-24LTS14  
HSU-07LEK03  
HSU-10LQA13  
HSU-15LQA13  
AS12GS1ERA  
AS18GS1ERA  
HSU-10LQAB13  
HSU-15LQAB13  
AS12GB2LAA  
HSU-10VEK03  
HSU-13VEK03  
HSU-18VEK03  
HSU-24VEK03  
AS05GA1LAA  
AS09GA1LAA  
AS12GB1LAA  
AS18GD1LAA  
HSU-19CXAR3N  
HSU-19CXBW3N  
Contents  
HSU-09LQA03/R2(DB)  
HSU-12LQA03/R2(DB)  
HSU-09LQA13/R2(DB)-WT  
HSU-09LQA13/R2(DB)-BK  
HSU-12LQA13/R2(DB)-WT  
HSU-12LQA13/R2(DB)-BK  
HSU-12LEK03/R2(DB)  
HSU-18LEK03/R2(DB)  
HSM24HEK03/R2(DB)  
2
3
6
7
8
PARTS AND FUNCTIONS  
OPERATION  
MAINTENANCE  
CAUTIONS  
TROUBLE SHOOTING  
Please read this operation manual before using the air conditioner.  
Keep this operation manual for future reference.  
0010564364  
Operation  
Base Operation  
Emergency operation and test operation  
Emergency Operation:  
Use this operation only when the remote controller is defective  
or lost, and with function of emergency running, air conditoner  
can run automatically for a while.  
TURBO  
/QUIET  
Remote controller  
1
When the emergency operation switch is pressed, the " Pi "  
sound is heard once, which means the start of this operation.  
When power switch is turning on for the first time and  
emergency operation starts, the unit will run automatically in  
2
3
SWING  
4
the following modes:  
Pi  
2
3
SLEEP  
HEALTH  
Room  
Timer  
Designated  
Fan Operation  
mode  
TIME  
ON  
TIME  
OFF  
temperature temperature mode speed  
Above 23oC 26oC  
AUTO COOL  
No  
It is impossible to change the settings of temp. and fan speed,It  
is also not possible to operate in timer or dry mode.  
1. Unit start  
Press ON/OFF on the remote controller, unit starts.  
Test operation:  
Test operation switch is the same as emergency switch.  
Use this switch in the test operation when the room  
temperature is below 16oC, do not use it in the  
2. Select operation mode  
COOL button:Cooling mode  
FAN button: Faning mode  
DRY button: Dehumidify mode  
Pi Pi  
normal operation.  
Continue to press the test operation  
switch for more than 5 seconds. After  
3.Select temp.setting  
you hear the "Pi" sound twice,  
release  
button  
Press  
/
your finger from the switch: the cooling  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
operation starts with the air flow speed "Hi".  
Under this operation mode,the fan motor of indoor  
unit will run in high speed.  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will  
decrease rapidly  
Air Flow Direction Adjustment  
Select a desired temperature.  
1.Status display of air flow  
4.Fan speed selection  
Vertical flap  
Press FAN button. For each press, fan speed  
changes as follows:  
Remote controller:  
Display  
Pos.1  
(Auto swing)  
Initial state  
circulated  
Pos.2 No initial state disaplayed on remote controller, the  
vertical flap will be fixed on the current position  
MED  
HI  
LOW  
AUTO  
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
2.Left and right air flow adjustment  
For each press of  
button, remote controller  
displays as follows :  
remote controller:  
Remote  
Controller  
Operation  
Mode  
Pos.3  
Pos.1  
Pos.5  
Pos.4  
Pos.2  
Pos.6  
Note  
Under the mode of auto operation, air conditioner will  
automatically select Cool or Heat operation according to  
room temperature. When FAN is set to AUTO the air  
conditioner automatically adjusts the fan speed according  
to room temperature.  
AUTO  
Cautions:  
according to room temperature.  
When adjusting the flap by hand,turn off the unit.  
When humidity is high,condensate water might occur  
adjusted to left or at air outlet if all vertical louvers are right.  
It is advisable not to keep horizontal flap at downward  
position for a long time in COOLor DRY  
otherwise, condensate water might occur.  
COOL  
DRY  
In DRY mode, when room temperature becomes lower  
than temp.setting+2o C, unit will run intermittently at LOW  
speed regardless of FAN setting.  
In FAN operation mode , the unit will not operate in COOL or  
HEAT mode but only in FAN mode, AUTO is not available in  
FAN mode. And temp. setting is disabled. In FAN mode,  
sleep operation is not available.  
mode ,  
FAN  
Note:  
When restart after remote turning off, the remote controller  
controller will automatically memorize the previous set swing position.  
3
Operation  
Sleep Operation  
Note  
When TIMER function is set, the sleeping function can’t be  
set up .After the sleeping function is set up, if user resets  
TIMER function, the sleeping function will be cancelled; the  
machine will be in the state of timing-on.  
Before going to bed,you can simply press the SLEEP  
button and unit will operate in SLEEP mode and bring  
you a sound sleep.  
TURBO/QUIET Operation  
TURBO/QUIET  
TURBO/QUIET  
Operation Mode  
When you need fast cool or fast dehumidification,you can  
choose the Turob function; when you sleep, read, you can  
choose Quiet function  
1. In COOL,DRY mode  
1 hours after SLEEP mode starts,temp.will become OC  
1
higher than temp.setting.After another 1 hours,temp.rises  
by 1OC futher.The unit will run for further 6 hours then stops  
T
emp. is higher than temp.setting so that room temperature  
Press the  
bu on, you can switch the “Turbo” and “Quiet”  
TURBO/QUIET  
won’t be too low for your sleep.  
will swith as below  
SLEEP operation starts  
SLEEP operation stops  
Approx.6hrs  
TURBO)  
QUIET)  
cancel  
Rises 1OC  
1 hr  
Rises 1OC  
1 hr  
When running in Turbothe fan speed is the highest,  
Temp.setting  
Unit stop  
when running in Quiet, the fan speed is super slow  
In COOL, DRY mode  
HEALTH Operation  
In AUTO mode  
2.  
The unit operaters in corresponding sleep mode  
Nano-Aqua generator adopt two high voltage  
pole to ionize the water molecule into  
nanometer water ion,and release these ions  
to the air to kill the bacterium and refresh  
the air. as well as the nanometer water inon  
can be easily absorbed by skin,keeping moisture  
anytime.  
adapted to the automatically selected operation mode.  
3. In FAN mode  
It has no SLEEP function.  
4.Set the wind speed change when sleeping  
If the wind speed is high or middle before setting for the  
sleep, set for lowing the wind speed after sleeping.  
If it is low wind, no change.  
4
Operation  
Timer On/Off On-Off Operation  
Health airflow Operation  
1.Press  
to starting  
1.After unit starts, select your desired operation mode.  
Setting the comfort work conditions.  
2.The setting of healthy airflow function  
Press button to select “ Healthy airflow”, the remote  
2.Press TIMER button to change TIMER mode. Every  
time the button is pressed, display changes as follows:  
Remote controller:  
controller will switch as below  
BLANK  
Healthy  
airflow  
Healthy  
airflow  
downwarder  
0.5h  
0.5h  
0.5h  
TIMER ON-OFF  
0.5h  
TIMER OFF-ON  
fixed  
location  
TIMER ON TIMER OFF  
upwarder  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF or TIMER ON-OFF). " "or " "will flash.  
Notice: Do not direct the flap by hand. Otherwise, the  
grille will run incorrectly. If the grille is not run correctly,  
stop for a minute and then start, adjusting by remote  
controller.  
3.Press  
/
button to set time.  
Press the button for each time, setting time in the first  
12 hours increased by 0.5 hour every time, after 12  
hours,increased by 1 hour every time.  
Note:  
1.After setting the healthy airflow function, the position  
Press the button for each time, settiing time in the first  
12 hours decreased by 0.5 hour every time, after 12  
hours,decreased by 1 hour every time.  
grill is fixed.  
2.In cooling, it is better to select the  
mode.  
It can be adjusted within 24 hours.  
3.In cooling and dry, using the air conditioner for a long  
time under the high air humidity, condensate water may  
4.Confirm timer setting  
After adjust the time,press  
button and confirm the  
occur at the grille .  
time ON or OFF button will not flash any more.  
5.Cancel timer setting  
Press the timer button by times until the time display  
eliminated.  
Hints:  
After replacing batteries or a power failure happens, time  
setting should be reset.  
According to the Time setting sequence of TIMER ON or  
TIMER OFF, either Start-Stop or Stop-Start can be  
achieved.  
5
Maintenance  
For Smart Use of The Air Conditioner  
Remote Controller  
Indoor Body  
Setting of proper room  
temperature  
Do not block the air inlet  
or outlet  
Proper  
temperature  
wipe the air conditioner by using a  
soft and dry cloth.For serious stains,  
use a neutral detergent diluted with  
water.Wring the water out of the  
cloth before wiping,then wipe off the  
detergent completely.  
Do not usewater,wipe the controller  
with a dry cloth.Do not use glass  
cleaner or chemical cloth.  
Do not use the following for cleaning  
Close doors and windows  
during operation  
Use the timer effectively  
O
O
Gasoline,benzine, thinner or cleanser Hot water over 40 C(104 F) may  
may damage the coating of the unit.  
cause discoloring or deformation.  
During cooling operation  
prevent the penetration  
of direct sunlight with  
curtain or blind  
Air Filter cleaning  
Open the inlet grille by pulling it upward.  
Remove the filter.  
Push up the filter's center tab slightly until it is  
released from the stopper, and remove the filter downward.  
Clean the filter.  
If the unit is not to be used  
for a long time, turn off the  
power supply main switch.  
Use the louvers effectively  
Use a vacuum cleaner to remove dust, or wash the filter with  
water.After washing, dry the filter completely in the shade.  
Attach the filter.  
Attach the filter correctly so that the "FRONT" indication  
is facing to the front.Make sure that the filter is  
completely  
fixed behind the stopper.If theright  
Once every  
two weeks  
and left filters are not attached correctly, that  
may cause defects.  
OFF  
Close the inlet grille.  
Replacement of Air Purifying Filter  
1.Open the lnlet Grille  
4.Attach the standard air filter  
(Necessary installation)  
Prop up the inlet grille by using a  
small device named grille-support  
which located in the right side of  
the indoor unit.  
ATTENTION:  
The white side of the photocatalyst air purifying filter  
face outside,and the black side face the unit The green  
side of the bacteria-killing medium air purifying filter face  
outside,and the white side face the unit.  
2.Detach the standard air filter  
Slide the knob slightly upward to  
release the filter, then withdraw it.  
5.Close the Inlet Grille  
Close the Grille surely  
NOTE:  
Detach old Air Purifying Filter  
The photocatalyst air purifying filter will be solarized in fixed  
time. In normal family, it will be solarized every 6 months.  
The bacteria-killing medium air purifying filter will be used  
for a long time,no need for replacement. But in the period  
of using them ,you should remove the dust frequently by  
using vacuum cleaner or flaping them lightly,otherwise ,  
its performance will be affected.  
3.Attach Air Purifying Filter  
Put air purifying filter appliances into the  
right and left filter frames.  
Please keep the bacteria-killing medium air purifying filter in  
the cool and dry conditions avoid long time directly sunshine  
when you stop using it,or its ability of sterilization will be  
reduced.  
6
Cautions  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
WARNING  
When abnormality such as burnt-small found,  
immediately stop the operation button and  
contact sales shop.  
Check proper  
installation of the  
drainage securely  
Use an exclusive  
power source  
with a circuit  
breaker  
STRICT  
OFF  
STRICT  
ENFORCEMENT  
ENFORCEMENT  
1.Do not use power supply cord extended  
or connected in halfway  
Connect power supply cord  
to the outlet completely  
Use the proper voltage  
2.Do not install in the place where there is any  
possibility of inflammable gas leakage around the unit.  
3.Do not get the unit exposed  
to vapor or oil steam.  
STRICT  
ENFORCEMENT  
STRICT  
ENFORCEMENT  
PROHIBITION  
Take care not to damage  
the power supply cord.  
Do not use power supply  
cord in a bundle.  
Do not insert objects into the air  
inlet or outlet.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not channel the air flow directly  
at people, especially at infants or  
the aged.  
Do not start or stop the  
operation by disconnecting  
the power supply cord  
and so on.  
Do not try to repair or  
reconstruct by yourself.  
Connect the earth  
cable.  
earthing  
PROHIBITION  
PROHIBITION  
CAUTION  
Take fresh air occasionally especially  
when gas appliance is running at the  
same time.  
Do not operate the switch with  
wet hand.  
Do not use for the purpose of storage of  
food, art work, precise equipment,  
breeding, or cultivation.  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
Do not pour water onto the unit  
for cleaning  
Do not install the unit near a fireplace  
or other heating apparatus.  
Check good condition of the  
installation stand  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not place flower vase or water  
containers on the top of the unit.  
Do not place any objects on or  
climb on the unit.  
Do not place animals or plants in  
the direct path of the air flow  
PROHIBITION  
PROHIBITION  
PROHIBITION  
7
Trouble shooting  
Cautions  
Before asking for service, check the following  
first.  
grille of the air  
Do not obstruct or cover the ventilation  
conditoner.Do not put fingers or any other things into the  
inlet/outlet and swing louver.  
Do not allow children to play with the air conditioner.In no  
case should children be allowed to sit on the outdoor unit.  
Phenomenon  
Cause or check points  
When unit is stopped, it won't restart  
immediately until 3 minutes have  
elapsed to protect the system.  
When the electric plug is pulled out  
and reinserted, the protection circuit  
will work for 3 minutes to protect the  
air conditioner.  
The system  
does not restart  
immediately.  
Specifications  
The refrigerating circuit is leak-proof.  
The machine is adaptive in following situation  
1.Applicable ambient temperature range:  
During unit operation or at stop,  
a swishing or gurgling noise may  
be heard.At first 2-3 minutes after  
unit start, this noise is more noticeable.  
(This noise is generated by  
refrigerant flowing in the system.)  
During unit operation, a cracking  
noise may be heard.This noise is  
generated by the casing expanding  
or shrinking because of  
32oC/23oC  
Noise is heard  
Maximum:D.B/W.B  
Indoor  
21oC/15oC  
Minimum:D.B/W.B  
Maximum:D.B/W.B 46oC/26oC  
Cooling  
Outdoor  
Minimum:  
18oC  
D.B  
Normal  
Performance  
inspection  
temperature changes.  
Should there be a big noise from  
air flow in unit operation, air  
filter may be too dirty.  
2. If the power supply cord is damaged, it must be replaced by the  
or its service agent or a similar  
person.  
manufacturer  
qualified  
This is because the system  
circulates smells from the interior  
air such as the smell of furniture,  
paint, cigarettes.  
Smells are  
generated.  
3.If the fuse of indoor unit on PC board is broken,please change  
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is  
broken,change it with the type of T.25A/250V  
Mist or steam are  
blown out.  
During COOL or DRY operation,  
indoor unit may blow out mist.  
This is due to the sudden cooling  
of indoor air.  
4. The wiring method should be in line with the local wiring standard.  
5. After installation, the power plug should be easily reached.  
6. The waste battery should be disposedproperly.  
In DRY mode, when room temperature  
becomes lower than temp.  
setting+2 oC,unit will run  
intermittently at LOW speed  
regardless of FAN setting.  
fan  
In dry mode,  
7. The appliance is not intended for use  
speed can’t be  
changed.  
by young children or infirm  
without supervision.  
persons  
8.Young children should be supervised to ensure that they do not play  
with the appliance.  
Is power plug inserted?  
Is there a power failure?  
Is fuse blownout?  
9. Please employ the proper power plug,which fit into the power supply  
cord.  
Is the air filter dirty?  
Normally it should be cleaned  
Poor cooling  
every 15 days.  
Multiple  
check  
must have acquired the local  
The power plug and connecting cable  
attestation.  
10.  
Are there any obstacles before  
inlet and outlet?  
Is temperature set correctly?  
11.In order to protect the units,please turn off the A/C first,and at least  
30 seconds later, cutting off the power.  
Are there some doors or  
windows left open?  
Is there any direct sunlight  
through the window during the  
cooling operation?(Use curtain)  
Are there too much heat sources  
or too many people in the room  
during cooling operation?  
Haier  
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China  
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010  
8

Briggs Stratton 8FBC User Manual
Cornelius Agitator Motor Universal 750 User Manual
Curtis FRW218B User Manual
Friedrich Air Conditioner XQ05M10 User Manual
GE AZ85E12EAC User Manual
Grizzly All in One Printer T23094 User Manual
Haier AS072ADAAA User Manual
Haier HSU 07LEK03 User Manual
Honda Automobiles Automobile Accessories User Manual
Honeywell HZ 614 User Manual