SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HEA03/(BP)
HSU-12HEA03/(BP)
Please read this operation manual before using the air conditioner.
0010518526
Cautions
7. The appliance is not intended for use
by young children or infirm persons
without supervision.
Do not obstruct or cover the ventilation
grille of the air conditoner.Do not put fingers
or any other things into the inlet/outlet and
swing louver.
8.Young children should be supervised
to ensure that they do not play with
the applience.
Do not allow children to play with the air
conditioner.In no case should children be
allowed to sit on the outdoor unit.
9.Please employ the proper power plug,
which fit into the power supply cord.
Specifications
10 .The power plug and connecting cable
must have acquired the local attestation.
The refrigerating circuit is leak-proof.
The machine is adaptive in following
situation
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds
later, cutting off the power.
1.Applicable ambient temperature range:
32oC/23oC
18oC/14oC
Maximum:D.B/W.B
Indoor
Minimum:D.B/W.B
Cooling
43oC/26oC
Maximum:D.B/W.B
Outdoor
Indoor
18oC
Minimum:D.B
27oC
15oC
Maximum:D.B
Minimum:D.B
Heating
24oC/18oC
-7oC/-8oC
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
3. If the fuse of indoor unit on PC board is
broken,please change it with the type of
T. 3.15A/ 250V.
4. The wiring method should be in line with
the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
2
Parts and Functions
Indoor Unit
Outlet
Display board
Inlet
Air filter(inside)
Air Purifying Filter
(inside)
Power plug
Inlet grille
Horizontal flap
(adjust up and down air flow.
Don't adjust it manually)
Anion generator
(inside)
Vertical blade
(adjust left and right air flow)
Actual inlet grille may vary from the one shown in the manual according to
the product purchased
Outdoor Unit
HSU-09HEA03/(BP)
HSU-12HEA03/(BP)
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
3
Parts and Functions
Display board
Remote controller
1
6
7
8
9
10
11
5
2
3
4
ON
OFF
A
U
T
O
AM
PM
oC
4
25
26
9
1
1
8
5
7. SIGNAL SENDING display
8. TIMER OFF display
9. TIMER ON display
10. CLOCK display
ON/OFF
TEMP
11. TEMP display
12
13
12. POWER ON/OFF
19
20
Used for unit start and stop.
MODE
FAN
SET
13. MODE
Used to select
COOL,DRY,HEAT operation
14. FAN
TIMER
Used to select fan speed AUTO, HI, MED, LO
21
22
15. HOUR
14
15
Used to set clock and timer setting.
16. SWING
CLOCK
POWER/SOFT
RESET
SWING
Used to set auto fan direction.
16
17. POWER/SOFT button
HEALTH
18. LOCK
17
24
Used to lock buttons and LCD display.
19. TEMP.
Used to select your desired temp.
LOCK
20. SET
18
23
Used to confirm timer and clock settings.
21. TIMER
Used to select TIMER ON, TIMER OFF,
1. Operation mode display
COOL DRY
HEAT
Operation mode
Remote controller
Display board
22. CLOCK
Used to set correct time
23. RESET
Used to reset the controller back to
normal condition.
24. HEALTH
2. SWING display
Used to operate the healthy function
3. FAN SPEED display
4. HEALTH display
5. POWER/SOFT display
MED
LO
AUTO
HI
25.
Singal receiver hole
26. Ambient temp.display
When receiving the remote control signal, display the set
temperature and in the rest time the room temperature is
displayed and this room temperature is only for reference.
6. LOCK display
Clock set
When unit is started for the first time and after replacing batteries in remote controller,
clock should be adjusted as follows:
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press will increase or decrease 1min. If the
button is kept depressed, time will change quickly.
After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
The unit do not have functions related with healthing.
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying
all information on LCD. Then, it will become normal.
4
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the
receiver hole on the indoor unit.
The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receivering the signals
so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú
7#
µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·Àֹ©ҹÇ뽫µç³ØÈ¡
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú
7#
µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·Àֹ©ҹÇ뽫µç³ØÈ¡
³ö¡£
ÔÚʹÓÃÖÐÈçÓöÒì³£,Çë
³ö¡£
ÔÚʹÓÃÖÐÈçÓöÒì³£,Çë
½«µç³ØÈ¡³ö,6·ÖÖÓºóÔÙ
×°Èëеç³Ø¡£
½«µç³ØÈ¡³ö,6·ÖÖÓºóÔÙ
×°Èëеç³Ø¡£
º£¶û¼¯ÍÅÇൺº£¶û
º£¶û¼¯ÍÅÇൺº£¶û
¿Õµ÷Æ÷ÓÐÏÞ×ܹ«Ë¾
¿Õµ÷Æ÷ÓÐÏÞ×ܹ«Ë¾
Load the battery:
Be sure that the loading is in line with the" + "/"-"
pole request as illustrated.
Put on the cover again
Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading.
If the remote controller can't run normally or doesn't work at all,
use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display after taking-out just need to press reset key.
5
Operation
Cool Operation
(1) Unit start
Press ON/OFF button, unit starts.
Previous operation status appears on display. (Not Timer setting)
(2) Select operation mode
Press MODE button. For each press, operation
mode changes as follows:
ON/OFF
TEMP
COOL
DRY
HEAT
1
4
MODE
SET
Unit will run in operation mode displayed on LCD.
Stop display at your desired mode.
2
FAN
TIMER
3
(3) Select temp. setting
SWING
CLOCK
Press TEMP button.
Every time the button is pressed, temp. setting increases 1oC
Every time the button is pressed, temp. setting decreases 1oC
Unit will start running to reach the temp. setting on LCD.
HEALTH
POWER/SOFT
RESET
LOCK
(4) Fan speed selection
Press FAN button. For each press, fan speed changes
as follows:
Remote controller:
HI
MED
LO
AUTO
Air conditioner is running under displayed fan speed.
Air conditioner is running under displayed fan speed.
(5) Unit stop
Press ON/OFF button, the unit stops.
Hints
On cooling only unit, heating mode is not available.
Remote controller can memorize each operation status. When starting it next time,
just press ON/OFF button and unit will run in previous status.
No reelecting is needed.(TIMER ON/OFF、SWING needs reelecting)
6
Operation
Heat Operation
(1) Unit start
Press ON/OFF button, unit starts.
Previous operation status appears on display. (Not Timer setting)
(2) Select operation mode
Press MODE button. For each press, operation
mode changes as follows:
HEAT
COOL
DRY
ON/OFF
TEMP
Unit will run in operation mode displayed on LCD.
Stop display at your desired mode.
3
1
5
3
MODE
SET
2
(3) Select temp. setting
Press TEMP button.
FAN
TIMER
Every time the button is pressed, temp. setting increases 1oC
Every time the button is pressed, temp. setting decreases 1oC
Unit will start running to reach the temp. setting on LCD.
4
SWING
CLOCK
POWER/SOFT
RESET
HEALTH
(4) Fan speed selection
Press FAN button. For each press, fan speed changes
LOCK
as follows:
Remote controller:
HI
MED
LO
AUTO
IN HEAT mode, warm air will blow out after a short period
prevention function.
of the time due to cold-draft
(5) Unit stop
Press ON/OFF button, the unit stops.
Hints
Remote controller can memorize each operation status. When starting it next time,
just press ON/OFF button and unit will run in previous status.
7
Operation
Dry Operation
(1) Unit start
Press ON/OFF button, unit starts.
(2) Select operation mode
Press MODE button. For each press, operation
mode changes as follows:
HEAT
COOL
DRY
ON/OFF
TEMP
Unit will run in operation mode displayed on LCD.
Stop display at your desired mode.
3
1
6
3
MODE
SET
(3) Select temp. setting
Press TEMP button.
2
FAN
TIMER
Every time the button is pressed, temp. setting increases 1oC
Every time the button is pressed, temp. setting decreases 1oC
Unit will start running to reach the temp. setting on LCD.
4
SWING
CLOCK
5
POWER/SOFT
HEALTH
(4) Fan speed selection
Press FAN button. For each press, fan speed changes
as follows:
LOCK
RESET
HI
MED
LO
AUTO
COOL operation starts when room
temp. is higher than temp. setting.
Ultra-low air flow
Temp. setting+2oC
Temp. setting
Unit runs at the speed displayed on LCD.
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
On reaching temp. setting, unit
will run in mild DRY mode.
Hints
Remote controller can memorize each operation status. When starting it next time,
just press ON/OFF button and unit will run in previous status.
8
Operation
(5) Air flow direction adjustment
After operation mode is selected, horizontal flap will open automatically according to the mode.
Referring to the Fig.
COOL
About 10o
Up and down (Use remote controller)
Press SWING button, horizontal flap will move
within the range shown in the Fig. Press SWING
button stop it at a fixed position.
Left and right air flow adjustment
(manual)
Move the vertical blade by a knob on air
conditioner to adjust left and right direction
referring to Fig.
About 10o
About 45o
COOL
Cautions:
It is advisable not to keep horizontal flap at
Cautions:
When humidity is high, condensate water
might occur at air outlet if all vertical
louvers are adjusted to left or right.
downward position for a long time in COOL
or DRY mode, otherwise, condensate
water might occur.
Cautions:
(6) Unit stop
Unit won't restart until 3 minutes have
elapsed, due to system protection.
Press ON/OFF button.
Only time remains on LCD.
All indicators on indoor unit go out.
Horizontal flap closes automatically.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more
helpful for a better air circulation.
Be careful not to catch a cold when cold air blows downward.
It is harmful to your health in summer to go frequently in and out of places where temp.
difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue.
More than this, unit's load can be reduced and power consumption cut down as well. So, you'd
better set a temp. difference of 3-5oC between indoor and outdoor temp. in COOL mode.
9
Operation
TIMER Operation
Set Clock correctly before starting Timer operation
You can let unit start or stop automatically at following times: Before you wake up in the
morning, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1)After unit start, select your desired operation mode.
Operation mode will be displayed on LCD.
Power indicator on indoor unit lights up.
(2)TIMER mode selection
ON
Press TIMER button to change TIMER mode.
Every time the button is pressed, display changes as follows:
blank
ON/OFF
TEMP
ON
OFF
TIMER ON TIMER OFF
1
MODE
Select your desired TIMER mode (TIMER ON or TIMER
OFF) ON or OFF will flash.
SET
3
4
FAN
TIMER
(3)Timer setting
3
Press HOUR
/
button.
2
SWING
CLOCK
Every time the button is pressed, time increases 1 hour.
If button is kept depressed, time will change quickly.
Every time the button is pressed, time decreases 1 hour.
If button is kept depressed, time will change quickly. Time
will be shown on LCD. It can be adjusted within 24 hours.
HEALTH
POWER/SOFT
LOCK
RESET
(4)Confirming your setting
After setting correct time, press SET button to confirm, "ON"
or "OFF" stops flashing
Time displayed: Unit starts or stops at x hour . (TIMER ON or
TIMER OFF).
Timer mode indicator on indoor unit lights up.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints
After replacing batteries or a power failure happens, Time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time, just
press SET button after mode selecting if timer setting is the same as previous one.
10
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use
this funciton.
ON/OFF
TEMP
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is
pressed,display
MODE
FAN
SET
changes as follows:
BLANK
TIMER
SOFT
POWER
Stop the display at
SWING
CLOCK
In POWER operation status:
In COOL mode, fan speed automatically runs in HI mode
for 15 min then returns to original status setting.
HEALTH
POWER/SOFT
To cancel POWER operation
LOCK
RESET
Press POWER/SOFT button twice ,POWER/SOFT disappears.
SOFT Operation
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
BLANK
SOFT
POWER
Stop the display at
In SOFT operation mode, fan speed automatically takes"LOW"
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
Hints:
During POWER operation, in rapid COOL mode, the roor
will show inhomogeneous temperature distribution.
Long period SOFT operation will cause effect of not too cool.
11
Operation
Emergency operation and test operation
Emergency Operation:
Carry out this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed, a" Pi "sound starts once, which
means the start of this operation.
In this operation, it is not possible to change the
settings of temperature and air flow speed, it is
also impossible to do an operation by the timer.
Follow the requirements below.
Pi
Room
Timer
mode
Designated
temperature
Air flow Operation
temperature
speed
mode
COOL
HEAT
More than 23oC
Less than 23oC
26oC
23oC
CONTINUOUS AUTO
CONTINUOUS AUTO
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23oC.
Heating when the room temperature at the start of operation is below 23oC
Test operation:
Pi Pi
Use this switch in the test operation when the room
temperature is less 16oC, do not use it in the normal
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch, the cooling
operation starts with the air flow speed setting "Hi".
Removal of the restriction of emergency or test operation:
Press once more the emergency operation switch, or manipulate through the remote
controller, a "Pi" sound causes the restriction of emergency or test operation to be
removed.
When the remote controller is manipulated for the removal, then the selected operation
by the remote controller.
12
Maintenance
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a small device named
grille-support which located in the right side of the ind-
oor unit.
2.Detach the standard air filter
Slide the knob slightly upward to release the
filter, then withdraw it.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessary installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,
and the black side face the unit.
The green side of the bacteria-killing medium air purifying filter face outside,
and the white side face the unit.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
it will be solarized every 6 months.
The bacteria-killing medium air purifying filter will be used for a long time,no need for
replacement. But in the period of using them ,you should remove the dust frequently
by using vacuum cleaner or flaping them lightly,otherwise ,its performance will be
affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions
avoid long time directly sunshine when you stop using it,or its ability of sterilization will
be reduced.
13
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room
temperature
Do not block the air inlet
or outlet
Proper
temperature
Close doors and windows Use the timer effectively
during operation
During cooling operation
prevent the penetration of
direct sunlight with
curtain or blind
If the unit is not to be used Use the louvers effectively
for a long time, turn off the
power supply main switch.
OFF
14
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to
the seriousness of possible risks and damages as follows. Compliance to the
instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Do not install in the
place where there is
any possibility of
inflammable gas
leakage around the
unit.
Do not get the unit
exposed to vapor
or oil steam.
Connect the earth
cable.
Check proper
installation of the
drainage securely
earthing
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
15
Cautions
WARNING
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
Use an exclusive power source with a
circuit breaker
STRICT
ENFORCEMENT
OFF
Connect power supply cord
to the outlet completely
Use the proper voltage
Do not use power supply cord
extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
ENFORCEMENT
PROHIBITION
Do not insert objects into the air
inlet or outlet.
Take care not to damage
the power supply cord.
Do not use power supply cord
in a bundle.
PROHIBITION
PROHIBITION
PROHIBITION
Do not channel the air flow directly
at people, especially at infants or
the aged.
Do not start or stop the
operation by disconnecting
the power supply cord and so on.
Do not try to repair or reconstruct
by yourself.
PROHIBITION
PROHIBITION
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
Do not operate the switch with
wet hand.
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
Do not pour water onto the unit
for cleaning
Do not install the unit near a fireplace
or other heating apparatus.
Check good condition of the
installation stand
PROHIBITION
PROHIBITION
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
Do not place flower vase or water
containers on the top of the unit.
Do not place any objects on or
climb on the unit.
PROHIBITION
PROHIBITION
PROHIBITION
16
Trouble shooting
Before asking for service, check the following first.
Phenomenon
Cause or check points
The system does not restart
immediately.
When unit is stopped, it won't restart
immediately until 3 minutes have elapsed
to protect the system.
When the electric plug is pulled out and
reinserted, the protection circuit will work
for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing
or gurgling noise may be heard. At first 2-3
minutes after unit start, this noise is more
noticeable. (This noise is generated by
refrigerant flowing in the system.)
Noise is heard
Normal
Performance
inspection
During unit operation, a cracking noise may
be heard. This noise is generated by the
casing expanding or shrinking because of
temperature changes
Should there be a big noise from air flow in
unit operation, air filter may be too dirty.
This is because the system circulates smells
from the interior air such as the smell of
furniture, cigarettes.
Smells are generated.
Mist or steam are blown out.
During COOL or DRY operation, indoor unit
may blow out mist. This is due to the sudden
cooling of indoor air.
Does not work at all.
Poor cooling
Is power plug inserted?
Is there a power failure?
Is fuse blown out?
Multiple
check
Is the air filter dirty? Normally it should be
cleaned every 15 days.
Are there any obstacles before inlet and outlet?
Is temperature set correctly?
Are there some doors or windows left open?
Is there any direct sunlight through the
window during the cooling operation?(Use
curtain)
Are there too much heat sources or too many
people in the room during cooling operation?
Application temp. range of air conditioner -7oC~43oC.