All dual gate installations require a minimum of 10 Watts of solar charging power.  
Parts Included:  
A. Solar Panel  
G
D  
F  
B. Lag Screws (4)  
E  
C. Pipe Clamp (4)  
C  
D. Curved Pipe  
1
H
E. /4" Nuts (4)  
C  
1
1
F. /4" x /2" Bolt (4)  
G. Wire Nuts  
B  
H. Compass  
A
Tools Required :  
• Slotted (flat blade) Screwdriver  
7
/16" open end wrench  
©2007 GTO, Inc.  
RB905  
Rev. 11/5/07  
Printed in China for GTO, Inc.  
Step 3: All Mighty Mule and GTO/PRO DC powered gate operators have a POWER IN terminal on their control  
boards marked SOLAR for connecting the solar panel wires. Below are various types of terminals on GTO/PRO  
and Mighty Mule control boards, if your control board doesn't have this terminal, please call the GTO's Technical  
Service Department at (800)543-1236 or (850)575-4144 for assistance.  
Feed the free end of the solar panel wires into the control box and attach them to the SOLAR terminals on the  
POWER IN terminal block on the control board. The RED solar panel wire goes to the (+) POSITIVE Solar ter-  
minal and the BLACK solar panel wire goes to the (–) NEGATIVE Solar terminal. See diagram below.  
IMPORTANT: Improper installation of these wires will damage to the opener's control board.  
J1  
J2  
J9  
~
~
-
+
NC RLY-COM  
NO  
18 VAC SOLAR RELAY OUT  
~
~
+
18VAC  
SOLAR  
Solar Panel Wires  
RED  
BLK  
Solar Panel Wires  
RED  
BLK  
Attach RED solar panel wire to the  
SOLAR terminal marked (+).  
18VAC  
SOLAR  
PANEL  
AUX  
OUT  
Attach BLACK solar panel wire to the  
SOLAR terminal marked (–).  
Solar Panel Wires  
RED  
BLK  
GTO  
TRANSF  
LOCK  
PWR  
AUX  
RLY  
18VAC SOLAR  
18 VAC  
or  
SOLAR  
GTO  
AUX  
~
~
+
LOCK  
~
POWER IN  
Solar Panel Wires  
Solar Panel Wires  
RED  
BLK  
RED  
BLK  
3
Solar Zones and Gate Activity  
Use the table and map to determine the  
Estimated Gate Openings Per Day  
Zone 1 Zone 2 Zone 3  
number of operational cycles* per day  
to expect in your area, using 5 to 30  
Watts of charging power. Figures are  
shown for winter (minimum sunlight)  
and do not account for the use of any  
accessory items.  
Winter Ratings  
Single gate installation with 5 Watts of charging power  
Single gate installation with 10 Watts of charging power  
Single gate installation with 20 Watts of charging power  
Single gate installation with 30 Watts of charging power  
Dual gate installation with 10 Watts of charging power  
Dual gate installation with 20 Watts of charging power  
Dual gate installation with 30 Watts of charging power  
4
8
8
16  
28  
44  
8
13  
26  
38  
54  
13  
27  
41  
14  
20  
4
10  
16  
18  
28  
*An operational cycle is one full  
opening and closing of the gate.  
*Number of openings per day will  
depend on the length, weight, hard-  
ware and environmental conditions.  
All dual gate installations require a minimum of 10 Watts of solar charging power.  
Accessories will draw additional power from the battery; the more  
accessories you connect, the more power your system will require.  
We recommend that you purchase an extra 12V, 7 amp hour battery  
(RB500) for the FM500/502, SW2500/2502, SW3000XL/3200XL,  
SW4000XL/4200XL  
Zone 1  
Zone 3  
Zone 2  
Zone 3  
Zone 3  
Multiple Panel Installations  
Solar Panels connect in PARALLEL  
NOTE: All connections should  
be weather proofed using weather  
proof splice kits avilable at hard-  
ware and electrical supply stores.  
RED  
RED  
BLACK  
BLACK  
attach BLACK to negative (–) solar terminal on control board  
attach RED to positive (+) solar terminal on control board  
4
Other Mighty Mule and GTO/PRO  
Access Controls and Accessories  
Push Button Control (FM132)  
Unlit doorbell button for remote entry or exit control. Wires directly to the control board and  
uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately).  
Pin Lock (FM133)  
The Pin Lock substitutes for the clevis pin at the front end of the Mighty Mule® gate  
operators. Helps prevent theft of the operator from the gate, while allowing quick release of  
the operator.  
Key Chain Two Button Transmitter (FM134)  
The Key Chain Mini Transmitter is a miniature version of the Mighty Mule® entry trans-  
mitter and has the same adjustable code settings. 12 Volt battery included.  
Single Button Transmitter (FM135)  
The Mighty Mule® entry transmitter, with adjustable code settings, is standard equipment  
with all Mighty Mule® systems. 12 Volt battery included.  
Digital Keypad (FM137)  
The specially designed digital keypad can be easily installed as a wireless or wired keypad.  
It can be programmed to use up to 25 different personal identification number (PIN) codes.  
Each code is face programmable with additional security features built in. Wired installa-  
tions require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold  
separately). Requires 3 AA batteries (not included).  
2
5
8
0
3
6
9
1
4
7
Mounting Post (FM100) - In Ground  
This black powder coated pedestal is designed to provide convenient access to your keypad,  
wireless intercom, or other access control device from your vehicle. With its break down  
design it is easy to install and works well in most standard applications. Surface Mount  
Flanges (F102) and Extensions (F103) for added height are available.  
Gate Opening Sensor (FM138)  
The Mighty Mule® Gate Opening Sensor is designed for residential and agricultural applications and  
is compatible with all Mighty Mule® automatic gate operator models. The wand is an electromag-  
netic sensor, which offers 'hands free' operation of the Mighty Mule® Gate Operators with a 12 ft.  
radius of detection of vehicles in motion.  
Automatic Gate Lock Pull-to-Open (FM143)  
A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks  
automatically as gates open and close. Used with Mighty Mule® DC swing gate operating  
systems for maximum stability and security. Comes with a keyed manual release. Recom-  
mended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas.  
C
I
T
A
O
M
K
C
O
T
U
L
A
E
T
A
G
Wireless Entry Intercom / Keypad (FM136)  
Allows owner to screen guest at the gate before allowing access to the property. Keypad  
also allows owner to give up to 25 programmable entry codes to family, friends or approved  
delivery personnel. Codes can be permanent of temporary. Can be wireless up to 500 feet or  
hard wired up to 1000 feet. Additional base stations available (F3101MBC).  
5
Other Mighty Mule and GTO/PRO  
Access Controls and Accessories  
Replacement Battery (FM150)  
Standard 12 volt, 7.0 amp-hour, maintenance-free battery for the Mighty Mule® FM500 & FM502  
gate operator systems. This is the only battery approved for use with the Mighty Mule® FM500 &  
FM502 gate operator systems. Life expectancy is 3-5 years.  
Low Voltage Wire (RB509)  
The 16 gauge, multi-stranded, dual conductor Low Voltage Wire is for connecting the AC powered  
transformer, or the Solar Panel to the control board. Also used for the connection of accessories, such  
as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV  
treated, PVC coated and ready for direct burial. Available in 50, 100, 250, 500 and 1000 foot rolls.  
11" Push to Open Bracket (FM148)  
Required when Mighty Mule® 500/502 gate operator(s) must push the gate open, such as on a sloping  
driveway or where space prevents gate(s) from opening inward (pulled open). Order two PTO brackets for  
conversion of a dual swing gate installation.  
Column Mount Lock Receiver (433IH)  
For mounting the Automatic Gate Lock on brick columns, walls, or for other applications with limited  
space between gate and post.  
Replacement Transformer (RB570)  
Standard 18 volt, 2200 mA, AC transformer for maintaining the battery included with the Mighty Mule®  
gate operator. This is the only transformer approved for use with all UL325 Mighty Mule® gate operator  
systems.  
Garage Door Receiver (RB709U)  
The Garage Door Receiver allows you to use the same Mighty Mule® entry transmitter (see Dual Trans-  
mitter) to operate your gate operator and your garage door operator. Compatible with most garage door  
operators.  
If you have a question about any special order item,  
just call 1-800-543-GATE!  
3121 Hartsfield Road • Tallahassee, Florida, USA 32303  
Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912  
or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950  
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced,  
downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright  
infringement is a violation of federal law.  
Mighty Mule¨, E-Z Gate¨, GTO¨, are registered trademarks of GTO, Inc. America’s DIY Automatic Gate Openers is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”).  
All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.  

Carrier 38HDR018 060 User Manual
Carrier 48HG14 28 User Manual
Carrier 48TM016 028 User Manual
Energizer E95 User Manual
Epson STYLUS NX410 User Manual
Friedrich CP08F10 User Manual
Friedrich CP12F10 User Manual
Friedrich MW24C3E User Manual
GE Zoneline AZ28E12EAC User Manual
Havis Shields C VS 1200 EXPD 1 User Manual