GE Zoneline AZ28E09DAB User Manual

GE Appliances  
AZ28E09D – GE Zoneline® Deluxe Series Cooling and Electric Heat Unit  
Wall Case Dimensions  
Maximum Cord Extension (in inches)  
Electrical Wiring  
All wiring, including installation of receptacle, must be made in  
accordance with local electrical codes and regulations.  
A
Note: Aluminum wiring may pose special problems – consult  
a qualified electrician.  
Grille Options  
Stamped Aluminum Grille – RAG60  
Exterior Architectural Louvers Durable Polycarbonate:  
C
RAG61 or RAG64 (Beige)  
RAG63 or RAG66 (Bittersweet)  
21  
58  
RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)  
Retrofit Kits:  
B
RAK901L – Wall Case Insulation for use with heat pumps.  
RAK40 – Deflector Kit to adapt chassis for use with existing  
exterior architectural louvered grilles.  
RAB71 Wall Sleeve  
Wall Opening Dimensions  
Heavy-gauge galvanized steel, with insulation.  
A – 42", B – 13-3/4", C – 16"  
Add 1/4" to A and C dimensions for all cut-out size.  
RAB71 16-1/4" Min. H x 42-1/4" Min. W  
Ducted Applications  
2800 and 3800 series can be used with ductwork to heat or  
cool more than one room. RAK6052 Duct Adaptor is applied  
to top of case over air discharge/RAK601 Duct Extension is  
applied to right or left of adaptor. Locally fabricated ductwork  
may be added to extend to maximum recommended distance  
of 15 feet.  
RAB71 available in 16", 24", 28" and 31" depths  
RAB77 16-1/2" Min. H x 42-3/8" Min. W  
RAB77 Wall Sleeve  
Molded SMC fiberglass-reinforced polyester compound.  
A – 42-1/8", B– 13-7/8", C – 16-1/4  
230/208 Volt Line Cord Connected Units  
Min. Circuit  
Protection  
(Amps)  
Line Cord  
Kit  
Electric Heat  
(Btuh)  
Electric  
Heater Watts Heat Amps  
2,550/2,090  
3,450/2,820  
5,000/4,090  
Electric  
Electrical Connection  
230/208 volt units may be plugged into a receptacle. 265 volt  
units are provided with a junction box and require direct  
connection. (NEC Requires 265V Direct Connection) See  
Architects and Engineers Design Data Manual for electrical  
connection information including use of sub-base for direct  
connected units. Installation must comply with local electrical  
codes and regulations.  
RAK3153  
RAK3203  
RAK3303  
8,600/7,100  
11,700/9,600  
17,000/13,900  
11.6/10.6  
15.5/14.1  
22.3/20.3  
15  
20  
30  
230/208 Volt Sub-Base Connected Units  
Min. Circuit  
Protection  
(Amps)  
Electric Heat  
(Btuh)  
Electric  
Heater Watts Heat Amps  
Electric  
Power Connection kits required on all Zoneline chassis.  
Sub-Base  
RAK204D15P  
RAK204D20P  
RAK204D30P  
8,600/7,100  
11,700/9,600  
17,000/13,900  
2,550/2,090  
3,450/2,820  
5,000/4,090  
11.6/10.6  
15.5/14.1  
22.3/20.3  
15  
20  
30  
For answers to your Monogram,® GE Profileor  
GE® appliance questions, visit our website at  
ge.com or call GE Answer Center® service,  
800.626.2000.  
Specification Revised 4/06  
390506  

Briggs Stratton 129800 User Manual
Briggs Stratton VANGUARD 522447 User Manual
Briggs Stratton WI User Manual
Danby DWC612BLP User Manual
Danby Products Air Conditioner DPAC 12099 User Manual
GE ASV08FL User Manual
Haier HSU 119M07 User Manual
Honda Power Equipment iGX440 User Manual
Honeywell NIAGARA WEB 700 User Manual
HP Hewlett Packard LaserJet M1120n MFP User Manual