GE General Electric Air Conditioner agv18 User Manual

GE Appliances  
Room  
Air  
Conditioners  
Owners Manual &  
Installation Instructions  
AGP18  
AGV18  
Pub. No. 49-7370 CG 1-98  
IMPORTANT SAFETY INFORMATION.  
READ ALL INSTRUCTIONS BEFORE USING.  
SafeyInstr  
WARNING!  
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock  
or personal injury.  
uctions  
SAFETY PRECAUTIONS  
This air conditioner must be properly  
installed in accordance with the Installation  
Instructions before it is used.  
Turn the mode control to OFF and unplug  
your air conditioner before making any  
repairs.  
OpeaigInstr  
Repair or replace immediately all electric  
service cords that have become frayed or  
otherwise damaged.  
NOTE: We strongly recommend that any  
servicing be performed by a qualified  
individual.  
uctions  
Read and follow this Safety Information carefully.  
SAVE THESE INSTRUCTIONS  
laioInstr  
uctions  
T
r
ubleshotingT  
ips  
CustomSer  
vice  
3
 
About the controls on the air conditioner.  
The controls will look like one of the following.  
uctions  
OFF  
3
4
HIGH  
FAN  
HIGH  
COOL  
SafeyInstr  
2
5
LOW  
FAN  
MED  
COOL  
1
6
uctions  
LOW  
COOL  
MODE CONTROL  
TEMP CONTROL  
OpeaigInstr  
Controls  
Mode Controls  
Temp Controls  
HIGH COOL, LOW COOL and MED COOL provide  
The temp control is used to maintain the  
room temperature. The compressor will cycle  
on and off to keep the room at the same level  
of comfort. When you turn the knob to a  
higher number the indoor air will become  
cooler. Turn the knob to a lower number and  
the indoor air will become warmer.  
uctions  
cooling with different fan speeds.  
LOW FAN or HIGH FAN provides air circulation  
and filtering without cooling or heating.  
NOTE: If you move the switch from a cool setting to OFF or to  
a fan setting, wait at least 3 minutes before switching back to  
a cool setting.  
Cooling Descriptions  
laioInstr  
For Normal Cooling—Select HIGH COOL or MED  
COOL with the temp control  at  midpoint.  
ips  
For Maximum Cooling—Select HIGH COOL with the  
temp control at the highest number available on  
your knob.  
For Quieter & Nighttime Cooling—Select LOW COOL  
with the temp control at midpoint.  
ubleshotingT  
r
T
vice  
CustomSer  
4
 
SafeyInstr  
Additional controls and important information.  
uctions  
Vent Control  
The vent control is located above the control knobs.  
When set at CLOSE, only the air inside the room will  
be circulated and conditioned. When set at OPEN,  
some inside air is exhausted outside.  
OpeaigInstr  
To open the vent, pull the lever toward you.  
To close it, push it in.  
uctions  
Air Direction  
laioInstr  
CIRCULAIRE  
Fingertip pressure on the bank of horizontal louvers  
adjusts the air direction up or down.  
For fixed side-to-side air direction, set the  
Circulaire switch to ON until the desired air  
direction is obtained, then move it to OFF.  
For continuous side-to-side air circulation, set the  
Circulaire switch to ON and leave it there.  
uctions  
CIRCULAIRE  
OFF  
ON  
T
r
ubleshotingT  
ips  
CustomSer  
vice  
5
 
Care and cleaning of the air conditioner.  
uctions  
Grille and Case  
Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not  
from the wall outlet before cleaning.  
use bleach or abrasives.  
SafeyInstr  
Outdoor Coils  
The coils on the outdoor side of the air conditioner  
should be checked regularly. If they are clogged  
with dirt or soot they may be professionally steam  
cleaned, a service available through your GE  
service outlet.  
uctions  
OpeaigInstr  
Air Filter  
uctions  
The air filter behind the front grille should be  
checked and cleaned at least every 30 days or more  
often if necessary.  
To remove:  
Open the inlet grille upward by pulling out the  
bottom of the inlet grille.  
1
Using the tab, pull up slightly on the filter to  
release it and pull it down.  
laioInstr  
2
ips  
Clean the filter with warm, soapy water. Rinse and  
let the filter dry before replacing it.  
CAUTION: DO NOT operate the air conditioner without a  
filter because dirt and lint will clog it and reduce performance.  
ubleshotingT  
r
T
vice  
CustomSer  
6
 
SafeyInstr  
Preparing to install the air conditioner.  
Read these instructions completely and carefully.  
uctions  
Before You Begin  
NOTE TO INSTALLER: Leave these instructions with  
CAUTION:  
the air conditioner after installation is completed.  
Do not, under any circumstances, cut or  
remove the third (ground) prong from the  
power cord.  
NOTE TO CONSUMER: Keep this Owners Manual  
and Installation Instructions for future use.  
OpeaigInstr  
Do not change the plug on the power cord  
of this air conditioner.  
IMPORTANT NOTES:  
For personal safety, this air conditioner must be  
properly grounded.  
Aluminum house wiring may present  
special problems—consult a qualified  
electrician.  
It is important to have the wall outlet and circuit  
checked by a qualified electrician if there is any  
doubt as to whether a proper ground exists.  
uctions  
Follow National Electric Codes (NEC) and/or local  
codes and ordinances.  
laioInstr  
Electrical Requirements  
We recommend that this model be installed  
on its own single branch circuit supplying  
230/208-volt a.c., protected with a time  
delay fuse or circuit breaker.  
uctions  
This is recommended for best performance and  
to prevent overloading house or apartment wiring  
circuits, which could cause a possible fire hazard  
from overheating wires.  
T
r
ubleshotingT  
Tools You Will Need  
Phillips-head screwdriver  
Flat-blade screwdriver  
Ruler or tape measure  
Scissors or knife  
Pencil  
Level  
Hammer  
ips  
CustomSer  
vice  
7
 
Window Installation Instructions  
Parts Included  
uctions  
Top mounting rail  
Window  
sash seal  
Left  
SafeyInstr  
accordion  
panel  
Foam top  
window gasket  
Top mounting rail  
seal strip  
uctions  
OpeaigInstr  
Frame guide (2)  
Right  
accordion  
panel  
uctions  
Sill bracket (2)  
Support  
laioInstr  
bracket (2)  
Window locking  
bracket  
ips  
Type A (14)    
Type B (7)  
Type C (5)    
Type D (2)    
Carriage Bolt (2)  
Lock Nut (4)  
ubleshotingT  
r
T
vice  
CustomSer  
8
SafeyInstr  
Read completely, then follow step-by-step.  
uctions  
Window Requirements  
These instructions are for a standard double-  
hung window. You will need to modify them for  
other types of windows.  
1
The air conditioner can be installed without the  
accordion panels if needed to fit in a narrow  
window. See the window opening dimensions to  
the right.  
OpeaigInstr  
18² min.  
29² to 41²  
(With accordion panels)  
All supporting parts must be secured to firm  
wood, masonry or metal.  
The electrical outlet must be within reach of the  
power cord.  
uctions  
26² min.  
(Without accordion panels)  
Window opening dimensions are for a standard double-hung  
window.  
laioInstr  
Storm Window Requirements  
A storm window frame will not allow the air  
conditioner to tilt towards the outside and will keep  
it from draining properly. To adjust for this, attach a  
piece of wood to the stool.  
WOOD PIECES—  
2
WIDTH: 2²  
LENGTH: Long enough to fit inside the window  
frame.  
Wood  
uctions  
1/2² higher  
than frame  
THICKNESS: To determine the thickness, place a  
piece of wood on the stool to make it 1/2² higher  
than the top of the storm window frame.  
Stool  
Storm window  
frame  
Attach securely with nails or screws provided by  
the installer.  
T
r
ubleshotingT  
ips  
CustomSer  
vice  
9
Window Installation Instructions  
uctions  
Remove the Air Conditioner From the Case  
Remove the 2 shipping screws from the back of  
Slide the air conditioner from the case by  
gripping the base pan handle and pulling  
forward while bracing the case.  
3
A
C
the case.  
SafeyInstr  
Remove the 2 screws on each side of the case.  
Keep these for later use.  
B
Shipping screws  
uctions  
OpeaigInstr  
uctions  
Prepare the Window and the Case  
Cut the window sash seal to the proper length.  
Peel off the backing and attach the seal to the  
underside of the window sash.  
Remove the backing from the top mounting  
rail seal strip and attach the seal to the bottom  
of the top mounting rail.  
4
A
C
laioInstr  
ips  
Install the top mounting rail with 3 type A  
screws on the inside of the case. Insert the  
frames for the accordion panels into the top  
mounting rail and the frame guides. Attach  
the accordion panels to the side of the case  
using 5 type A screws.  
D
Carefully insert the plastic frame guides into  
the bottom of the case on each side.  
B
ubleshotingT  
r
T
Top mounting rail  
Bottom of case  
vice  
Frame guide  
CustomSer  
Frame guides  
10  
SafeyInstr  
uctions  
Prepare the Window  
Loosely attach the sill brackets to the support  
Open the window and mark the centerline of  
the window stool. Measure and mark 11² to the  
left and right of the centerline.  
5
6
A
B
brackets using the 2 carriage bolts and 2  
lock nuts.  
Support bracket  
Carriage  
bolt  
OpeaigInstr  
Lock nut  
11²  
Sill bracket  
Centerline  
uctions  
laioInstr  
Install the Case in the Window  
Align the inside edge of the sill brackets with  
the 11² mark from the centerline and attach  
them to the window sill using 2 type B screws  
on each side.  
Secure the case to the window stool by using 3  
type B screws.  
A
E
Carefully place the case on the window stool  
aligning the center front on the bottom with  
B
uctions  
the centerline marked on the window stool.  
Close the window making sure the window sash  
is behind the top mounting rail.  
Sill  
support  
Using the larger diameter hole in the case, attach  
C
the brackets to the case using two type D screws  
T
r
and 2 lock nuts.  
ubleshotingT  
Pull the accordion panels to each window  
sash track. Attach them on each side to the  
window sash and the window stool using  
4 type C screws.  
F
Type D screws  
with nuts  
ips  
Type B screws  
CustomSer  
Adjust the carriage bolts and the lock nuts in  
D
each support so that the case is installed with a  
slight downward tilt (about 1/8²). Tighten the  
bolts.  
CAUTION: DO NOT drill a hole in the base pan. The unit is  
designed to operate with approximately 1/2² of water in the  
base pan.  
vice  
11  
Window Installation Instructions  
uctions  
Install the Window Locking Bracket and the Foam Top Window Gasket  
Attach the window locking bracket with a  
type C screw.  
Cut the foam top window gasket to the window  
width.  
A
B
C
6
7
SafeyInstr  
Stuff the foam between the glass and the  
window to prevent air and insects from getting  
into the room.  
uctions  
OpeaigInstr  
Install the Air Conditioner in the Case  
Slide the air conditioner into the case.  
Attach the front grille to the case by inserting the  
tabs on the grille into the slots on the front of the  
case. Push the grille in until it snaps into place.  
uctions  
A
C
Reinstall the 2 screws removed earlier on each  
side of the case.  
Before installing the front grille, pull out the  
B
vent control lever located above the unit  
control knobs, as shown.  
laioInstr  
ips  
ubleshotingT  
r
T
Lift the inlet grille and secure the front grille  
with a type A screw. Lower the inlet grille into  
place.  
D
vice  
CustomSer  
12  
SafeyInstr  
Before you call for service…  
Troubleshooting Tips  
Save time and money! Review the chart below first and  
you may not need to call for service.  
uctions  
Problem  
Possible Causes  
What To Do  
Air conditioner  
does not start  
The air conditioner  
is unplugged.  
Make sure the air conditioner plug is pushed  
completely into the outlet.  
OpeaigInstr  
The fuse is blown/circuit  
breaker is tripped.  
Check the house fuse/circuit breaker box and replace  
the fuse or reset the breaker.  
Power failure.  
If power failure occurs, turn the mode control to OFF.  
When power is restored, wait 3 minutes to restart the  
air conditioner to prevent tripping of the compressor  
overload.  
uctions  
Air conditioner does  
not cool as it should  
Airflow is restricted.  
Make sure there are no curtains, blinds or furniture  
blocking the front of the air conditioner.  
The temp control may  
not be set high enough.  
Turn the knob to a higher number. The highest setting  
provides maximum cooling.  
laioInstr  
The air filter is dirty.  
Clean the filter at least every 30 days.  
See the Operating Instructions section.  
The room may have been hot.  
Cold air is escaping.  
When the air conditioner is first turned on you need to  
allow time for the room to cool down.  
Check for open furnace floor registers and cold  
air returns.  
uctions  
Set the air conditioner’s vent to the closed position.  
See “Air conditioner freezing up” below.  
Cooling coils have iced up.  
Air conditioner  
freezing up  
Ice blocks the air flow  
and stops the air conditioner  
from cooling the room.  
Set the mode control at HIGH FAN or HIGH COOL  
with the temp at 1 or 2.  
T
r
ubleshotingT  
Normal Operating Sounds  
You may hear a pinging noise caused by water  
being picked up and thrown against the  
Water will collect in the base pan during  
high humidity or on rainy days. The water  
condenser on rainy days or when the humidity is  
high. This design feature helps remove moisture  
and improve efficiency.  
may overflow and drip from the outdoor side  
of the unit.  
ips  
The fan may run even when the compressor  
You may hear the thermostat click when the  
is not.  
compressor cycles on and off.  
CustomSer  
vice  
13  
   
Notes  
uctions  
SafeyInstr  
uctions  
OpeaigInstr  
uctions  
laioInstr  
ips  
ubleshotingT  
r
T
vice  
CustomSer  
14  
SafeyInstr  
Air Conditioner Warranty  
All warranty service provided by our Factory Service Centers,  
or an authorized Customer Care® technician. For service,  
call 800-GE-CARES.  
uctions  
For The Period Of:  
GE Will Replace, At No Charge To You:  
One Year  
From the date of the  
original purchase  
Any part of the air conditioner which fails due to a defect in materials or workmanship.  
During this full one-year warranty, GE will also provide, free of charge, all labor  
and in-home service to replace the defective part.  
OpeaigInstr  
Five Years  
From the date of the  
original purchase  
Any part of the sealed refrigerating system (the compressor, condenser, evaporator  
and all connecting tubing) which fails due to a defect in materials or workmanship.  
During this five-year warranty, GE will also provide, free of charge, all labor and  
in-home service to replace the defective part.  
uctions  
What GE Will Not Cover:  
Service trips to your home to teach you how to use the  
product.  
Replacement of house fuses or resetting of circuit  
breakers.  
laioInstr  
Improper installation. If you have an installation problem, Failure due to corrosion on models not corrosion-  
or if the air conditioner is of improper cooling capacity  
for the intended use, contact your dealer or installer. You  
are responsible for providing adequate electrical  
connecting facilities.  
protected.  
Damage to the product caused by improper power supply  
voltage, accident, fire, floods or acts of God.  
Incidental or consequential damage to personal property  
caused by possible defects with this air conditioner.  
Failure of the product resulting from modifications to the  
product or due to unreasonable use including failure to  
provide reasonable and necessary maintenance.  
uctions  
In commercial locations labor necessary to move the unit  
to a location where it is accessible for service by an  
individual technician.  
T
r
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home  
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.  
ubleshotingT  
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives  
you specific legal rights, and you may also have other rights which vary from state to state. To know what your  
legal rights are, consult your local or state consumer affairs office or your states Attorney General.  
ips  
Warrantor: General Electric Company. Louisville, KY 40225  
CustomSer  
vice  
15  
Service Telephone Numbers.  
GE Answer Center® 800.626.2000  
uctions  
The GE Answer Center® is open 24 hours a day, 7 days a week.  
SafeyInstr  
In-Home Repair Service 800-GE-CARES (800-432-2737)  
Expert GE repair service is only a phone call away.  
uctions  
Special Needs Service 800.626.2000  
800-TDD-GEAC (800-833-4322)  
GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons  
with limited mobility.  
OpeaigInstr  
Service Contracts 800-626-2224  
Purchase a GE service contract while your warranty is still in effect and you’ll receive a  
substantial discount. GE Consumer Service will still be there after your warranty expires.  
uctions  
Parts and Accessories 800-626-2002  
Individuals qualified to service their own appliances can have parts or accessories sent directly  
to their homes (VISA, MasterCard and Discover cards are accepted).  
laioInstr  
Instructions contained in this manual cover procedures to be performed by any user. Other servicing  
generally should be referred to qualified service personnel. Caution must be exercised, since  
improper servicing may cause unsafe operation.  
ips  
Service Satisfaction  
If you are not satisfied with the service you receive from GE:  
First, contact the people who serviced your appliance.  
Next, if you are still not pleased, write all the details—including your phone number—to:  
ubleshotingT  
r
T
Manager, Consumer Relations  
GE Appliances  
Appliance Park  
Louisville, KY 40225  
Finally, if your problem is still not resolved, write:  
vice  
Major Appliance Consumer Action Program  
20 North Wacker Drive  
Chicago, IL 60606  
CustomSer  
Printed in Korea  
16  

Brother Printer DCP 8045D User Manual
Bryant 452 User Manual
Bryant 538MNC User Manual
Cornelius A8542 User Manual
Energizer Battery Charger CHU58 User Manual
Fedders A6X05F2D User Manual
Friedrich Air Conditioner E S12 User Manual
Friedrich CP05 User Manual
Fujitsu Air Conditioner AOU9RL2 User Manual
Honda Automobiles GX610 User Manual