Friedrich WallMaster US08B10A User Manual

THRU-THE-WALL AIR CONDITIONERS  
cool only | heat pumps | electric heat  
THRU-THE-WALL units mount flush with  
exterior walls for a sleek appearance, as well as  
unobstructed window views.  
(Wallmaster WSC sleeve shown with architectural  
grille. Uni-fit grille has different appearance.)  
Universal Fit for Easy Replacement  
Chassis installs into existing 26" sleeves  
Cooling only & eleCtriC heat  
• Rotary compressors provide  
quiet, dependable performance  
Auto re-start  
• Washable/reusable filter  
• Seacoast protection  
• Six-way air flow control  
• Stale air exhaust  
HEAT/COOL MODELS feature mechanical controls,  
two cooling speeds, two heating speeds, plus one  
fan-only setting.  
COOLING MODELS feature electronic controls  
with remote control, Money Saver® setting that  
saves energy by cycling the fan with the compres-  
sor and three cooling/three fan-only speeds.  
remote Control features (cool only models)  
• 12 hour programmable timer  
• Money Saver® setting saves energy by  
cycling the fan with the compressor  
remote  
Control  
12-hour money saVer  
timer feature  
Friedrich  
USC Sleeve  
Whirlpool/  
Fedders  
GE  
Amana  
Frigidaire  
Sleeve Dimensions  
Height (inches)  
15 17/32  
25 7/8  
15 5/8  
26  
15 5/8  
26  
15 3/4  
26 3/4  
15  
15 7/16  
25 7/8  
18  
Width (inches)  
tWo energystar models  
Depth (inches)  
16 23/32  
16 7/8  
16 7/8  
Units are shown without USC sleeve (USC sleeves sold and shipped separately)  
Commercial  
and residential  
applications  
ROOM AIR CONDITIONER  
Blocked side vents restrict air flow  
FRIEDRICH THRU-THE-WALL  
Solid-side sleeve (no side vents)  
When should you  
install a solid side  
sleeve?  
SOLID SIDE wall sleeve  
allows for installation in thick  
exterior walls where the  
installation of room air units  
with side vents would effect  
performance and may even  
void the warranty.  
CORRECT Vertical Louvers  
important:  
Operating the air conditioner  
with incorrect rear grille or  
without Baffle Adapter Kit  
(on 19 3/4” deep sleeve) will  
recirculate discharge air and  
cause compressor overload  
to trip.  
INCORRECT Horizontal Louvers  
WSC Sleeve/Standard Grille  
Installation Accessories (WallMaster only)  
DK / Drain Kit  
SB / Sub Base  
IDK / Internal Drain Kit  
Newconstructionapplications where  
a condensate drain system has been  
built into the wall interior.  
BAK / Baffle Adapter Kit  
Necessarywheninstallinginasleeve  
deeper than 16 3/4" deep, such as  
Fedders B sleeve (19 3/4" deep).  
Installedatthebackoftheunitandallows  
forattachmenttopermanent condensate  
disposal system, if disposal is necessary  
or desired.  
Used as a base for the unit when  
it is desired to place the cord and  
receptaclewithintheinstallation, or  
simply as a base for the unit when  
mounted low in the wall.  
163/4"  
FeddersB  
193/4”  
stanDarD grille – expanded aluminum  
For use with USC sleeve. (Ships with USC sleeve).  
*replaCement grille – high-tech plastic  
For use on existing sleeves without any grille. (Ships with  
chassis).  
important note:  
When installing into an existing sleeve, consult Installation  
Section of your Installation/Operation Manual to determine  
whether or not the grille needs to be replaced and/or a  
baffle adapter should be used.  
USC Sleeve/Standard Grille  
USC Sleeve/Replacement Grille*  
EnErgy Star® models  
Specifications  
Energy  
Cooling  
Heating  
Capacity  
BTU/h  
Efficiency Moisture  
Room  
Net  
Weight  
Lbs.  
Capacity  
Volts  
Rated  
Cooling  
Amps  
Cooling  
Watts  
Heating  
Amps  
Heating  
Watts  
Ratio  
EER  
Removal  
Side Air  
Model  
WALLMASTER  
BTU/h  
Pints/Hr. Circulation  
WS08B10A  
WS10B10A  
WS14B10A  
WS10B30A  
WS13B30B  
WS16B30A  
WE10B33C  
WE13B33C  
WE16B33C  
WY10B33C  
WY13B33C  
UNI-FIT  
US08B10A  
US10B10A  
US10B30A  
US12B10A  
US12B30B  
US14B30A  
UE08A13B  
UE10A33B  
UE12A33B  
8000  
115  
6.8  
762  
10.5  
10.5  
1.3  
2.4  
3.3  
2.1  
3.3  
4.2  
2.1  
3.3  
4.2  
2.5  
3.2  
245  
245  
295  
260  
280  
290  
260  
280  
290  
230  
280  
93  
10000  
115  
8.7  
954  
103  
112  
101  
109  
119  
103  
111  
121  
107  
116  
13500  
115  
12.0  
1415  
9.5  
10000/10000  
12500/12000  
15800/15000  
10000/10000  
12500/12000  
15800/15000  
10100/9800  
12500/12100  
230/208  
230/208  
230/208  
230/208  
230/208  
230/208  
230/208  
230/208  
4.6/5.0  
6.3/6.7  
7.8/8.5  
4.6/5.0  
6.3/6.7  
7.8/8.5  
4.6/4.8  
6.4/6.8  
1005/996  
1404/1379  
1756/1705  
1005/996  
1404/1379  
1756/1705  
1013/976  
1389/1352  
10.0/10.0  
8.9/8.7  
9.0/8.8  
10.0/10.0  
8.9/8.7  
9.0/8.8  
10.0/10.0  
9.0/9.0  
11000/9100  
11000/9100  
11000/9100  
8100/7800  
10400/10000  
16.0/14.7  
16.0/14.7  
16.0/14.7  
3.9/4.0  
5.4/5.7  
3550/2950  
3550/2950  
3550/2950  
857/821  
1182/1136  
8000  
9800  
115  
115  
7.5  
830  
9.6  
8.8  
9.4  
8.8  
8.8  
8.5  
9.6  
9.4  
8.8  
2.2  
3.2  
3.2  
3.8  
3.8  
4.0  
2.2  
3.2  
3.8  
260  
285  
285  
290  
290  
300  
260  
285  
290  
73  
78  
78  
80  
80  
84  
73  
78  
80  
10.2  
1110  
10000/9800  
11500  
230/208  
115  
4.7/5.2  
12.0  
1060/1040  
1310  
11500/11200  
13000/12600  
8000  
230/208  
230/208  
115  
6.0/6.4  
7.0/7.5  
7.5  
1310/1270  
1530/1480  
830  
3850  
10.7  
1230  
3500/2900  
3500/2900  
10000/9800  
11500/11200  
11200/9200  
11200/9200  
230/208  
230/208  
4.7/5.2  
6.0/6.4  
1060/1040  
1310/1270  
15.3/14.0  
15.3/14.0  
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)  
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.  
WALLMASTER HEAT PUMP  
HEATING PERFORMANCE  
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and termi-  
nated at 43°F (outdoor coil temperature). During defrost, the compressor stops  
and the electric heat starts, then operates with the fan to maintain indoor  
comfort. Below 43°F, the unit remains in electric heat mode. During electric heat  
mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7  
amps, and 3550/2950 watts.  
Change-over from heat pump operation to resistance operation on models  
indicated is automatic at a preset outside ambient temperature of approxi-  
mately 35°F.  
Calculate the heat loss of the space to be heated. As long as the heat loss does  
not exceed the resistance heating capacity rating of the unit, the heating per-  
formance will be satisfactory.  
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent  
condensate from freezing inside drain pan.  
Note: all models will produce condensate. If condensate disposal is desired, an  
optional drain kit is available.  
Plug Face/ Circuit Rating  
Circuit Rating  
Wall  
Plug Face  
WallMaster  
Uni-Fit  
Breaker  
Outlet  
Model Number  
Model Number  
or T-D Fuse  
(NEMA#) Appearance  
WS08B10A, WS10B10A,  
WS14B10A  
US08B10A, UE08A13B  
US10B10A, US12B10A  
125V - 15A  
250V - 15A  
250V - 20A  
5 - 15P  
6 - 15P  
6 - 20P  
WS10B30A, WS13B30A,  
WS16B30A  
US10B30A, US12B30B,  
US14B30A  
WE10, WE13, WE16  
WY10, WY13  
UE10A33B, UE12A33B  
As an EnErgy Star® partner, Friedrich Air Conditioning Co.  
has determined that the selected EnErgy Star® models ()  
meet the EnErgy Star® guidelines for energy efficiency.  
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com  
TTW-08  
Printed in USA  

Agilent Technologies All in One Printer 03561 90010 User Manual
Briggs Stratton 243400 User Manual
Brother IntelliFAX 1960C User Manual
Epson Stylus TX400 User Manual
Ferris Industries 5600056 User Manual
Friedrich WallMaster UE12A33B User Manual
Hand Held Products Dolphin 7200 User Manual
Havis Shields 1996 2008 Crown Victoria Swing Out Dash Monitor Mount S DMM XXX CV SO User Manual
HoMedics Massaging Lumbar Support Rest LUV 100 User Manual
Honda Automobiles GXV50 User Manual