THRU-THE-WALL AIR CONDITIONERS
cool only | heat pumps | electric heat
THRU-THE-WALL units mount flush with
exterior walls for a sleek appearance, as well as
unobstructed window views.
(Wallmaster WSC sleeve shown with architectural
grille. Uni-fit grille has different appearance.)
Universal Fit for Easy Replacement
Chassis installs into existing 26" sleeves
Cooling only & eleCtriC heat
• Rotary compressors provide
quiet, dependable performance
• Auto re-start
• Washable/reusable filter
• Seacoast protection
• Six-way air flow control
• Stale air exhaust
HEAT/COOL MODELS feature mechanical controls,
two cooling speeds, two heating speeds, plus one
fan-only setting.
COOLING MODELS feature electronic controls
with remote control, Money Saver® setting that
saves energy by cycling the fan with the compres-
sor and three cooling/three fan-only speeds.
remote Control features (cool only models)
• 12 hour programmable timer
• Money Saver® setting saves energy by
cycling the fan with the compressor
remote
Control
12-hour money saVer
timer feature
Friedrich
USC Sleeve
Whirlpool/
Fedders
GE
Amana
Frigidaire
Sleeve Dimensions
Height (inches)
15 17/32
25 7/8
15 5/8
26
15 5/8
26
15 3/4
26 3/4
15
15 7/16
25 7/8
18
Width (inches)
tWo energystar models
Depth (inches)
16 23/32
16 7/8
16 7/8
Units are shown without USC sleeve (USC sleeves sold and shipped separately)
CORRECT Vertical Louvers
Exterior Grilles
important:
Operating the air conditioner
with incorrect rear grille or
without Baffle Adapter Kit
(on 19 3/4” deep sleeve) will
recirculate discharge air and
cause compressor overload
to trip.
INCORRECT Horizontal Louvers
WSC Sleeve/Standard Grille WSC Sleeve/Optional Architectural Grille, AG
Installation Accessories (WallMaster only)
DK / Drain Kit
SB / Sub Base
IDK / Internal Drain Kit
Newconstructionapplications where
a condensate drain system has been
built into the wall interior.
BAK / Baffle Adapter Kit
Necessarywheninstallinginasleeve
deeper than 16 3/4" deep, such as
Fedders B sleeve (19 3/4" deep).
Installedatthebackoftheunitandallows
forattachmenttopermanent condensate
disposal system, if disposal is necessary
or desired.
Used as a base for the unit when
it is desired to place the cord and
receptaclewithintheinstallation, or
simply as a base for the unit when
mounted low in the wall.
163/4"
FeddersB
193/4”
Exterior Grilles
stanDarD grille – expanded aluminum
For use with USC sleeve. (Ships with USC sleeve).
*replaCement grille – high-tech plastic
For use on existing sleeves without any grille. (Ships with
chassis).
important note:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a
baffle adapter should be used.
USC Sleeve/Standard Grille
USC Sleeve/Replacement Grille*
Sleeve/Chassis Dimensions
Thru-the-wall
Finished Hole
Depth
Minimum
Minimum
important:
with
Extension Extension
Model
Height Width Depth
Front
Into Room
Outside
Height
Width
•
Sleeves are sold and shipped separately to accommodate
new construction and replacement requirements
WALLMASTER
16 3/4"
15 3/4" 26 1/2"
27"
16 3/4"
21"
23"
–
7 1/2"
–
9/16"
–
17 1/4"
–
27 1/4"
–
WSC Sleeve
Chassis
UNI-FIT
USC Sleeve
US Chassis
UE Chassis
15 1/2" 25 7/8" 16 3/4" 20 1/2"
–
1/2"
–
15 3/4"
–
–
26 1/8"
–
–
14 3/8"
24"
20 1/8"
19 5/8"
3 3/4"
3 1/2"
14 3/8" 24 5/8"
–
EnErgy Star® models
Specifications
Energy
Cooling
Heating
Capacity
BTU/h
Efficiency Moisture
Room
Net
Weight
Lbs.
Capacity
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Ratio
EER
Removal
Side Air
Model
WALLMASTER
BTU/h
Pints/Hr. Circulation
WS08B10A
WS10B10A
WS14B10A
WS10B30A
WS13B30B
WS16B30A
WE10B33C
WE13B33C
WE16B33C
WY10B33C
WY13B33C
UNI-FIT
US08B10A
US10B10A
US10B30A
US12B10A
US12B30B
US14B30A
UE08A13B
UE10A33B
UE12A33B
8000
—
—
115
6.8
762
—
—
—
—
10.5
10.5
1.3
2.4
3.3
2.1
3.3
4.2
2.1
3.3
4.2
2.5
3.2
245
245
295
260
280
290
260
280
290
230
280
93
10000
115
8.7
954
103
112
101
109
119
103
111
121
107
116
13500
—
115
12.0
1415
—
—
9.5
10000/10000
12500/12000
15800/15000
10000/10000
12500/12000
15800/15000
10100/9800
12500/12100
—
230/208
230/208
230/208
230/208
230/208
230/208
230/208
230/208
4.6/5.0
6.3/6.7
7.8/8.5
4.6/5.0
6.3/6.7
7.8/8.5
4.6/4.8
6.4/6.8
1005/996
1404/1379
1756/1705
1005/996
1404/1379
1756/1705
1013/976
1389/1352
—
—
10.0/10.0
8.9/8.7
9.0/8.8
10.0/10.0
8.9/8.7
9.0/8.8
10.0/10.0
9.0/9.0
—
—
—
—
—
—
11000/9100
11000/9100
11000/9100
8100/7800
10400/10000
16.0/14.7
16.0/14.7
16.0/14.7
3.9/4.0
5.4/5.7
3550/2950
3550/2950
3550/2950
857/821
1182/1136
8000
9800
—
—
115
115
7.5
830
—
—
—
—
9.6
8.8
9.4
8.8
8.8
8.5
9.6
9.4
8.8
2.2
3.2
3.2
3.8
3.8
4.0
2.2
3.2
3.8
260
285
285
290
290
300
260
285
290
73
78
78
80
80
84
73
78
80
10.2
1110
10000/9800
11500
—
230/208
115
4.7/5.2
12.0
1060/1040
1310
—
—
—
—
—
11500/11200
13000/12600
8000
—
230/208
230/208
115
6.0/6.4
7.0/7.5
7.5
1310/1270
1530/1480
830
—
—
—
—
—
3850
10.7
1230
3500/2900
3500/2900
10000/9800
11500/11200
11200/9200
11200/9200
230/208
230/208
4.7/5.2
6.0/6.4
1060/1040
1310/1270
15.3/14.0
15.3/14.0
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE
DEFROST CONTROL: Initiated at 20°F (outdoor coil temperature) and termi-
nated at 43°F (outdoor coil temperature). During defrost, the compressor stops
and the electric heat starts, then operates with the fan to maintain indoor
comfort. Below 43°F, the unit remains in electric heat mode. During electric heat
mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7
amps, and 3550/2950 watts.
Change-over from heat pump operation to resistance operation on models
indicated is automatic at a preset outside ambient temperature of approxi-
mately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating per-
formance will be satisfactory.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
Plug Face/ Circuit Rating
Circuit Rating
Wall
Plug Face
WallMaster
Uni-Fit
Breaker
Outlet
Model Number
Model Number
or T-D Fuse
(NEMA#) Appearance
WS08B10A, WS10B10A,
WS14B10A
US08B10A, UE08A13B
US10B10A, US12B10A
125V - 15A
250V - 15A
250V - 20A
5 - 15P
6 - 15P
6 - 20P
WS10B30A, WS13B30A,
WS16B30A
US10B30A, US12B30B,
US14B30A
WE10, WE13, WE16
WY10, WY13
UE10A33B, UE12A33B
As an EnErgy Star® partner, Friedrich Air Conditioning Co.
has determined that the selected EnErgy Star® models ()
meet the EnErgy Star® guidelines for energy efficiency.
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
TTW-08
Printed in USA
|