		 Installation & Operation Manual   
					Portable Air Conditioner   
					Models P09A and P12A   
					PAC-IO (10-07)   
				Unit Identification and Function   
					1.   
					2.   
					3.   
					4.   
					5.   
					6.   
					7.   
					8.   
					9.   
					10.   
					Control panel   
					Air outlet   
					Signal receptor   
					Handle   
					Caster   
					Air outlet hose   
					Air filter   
					Air intake hose   
					1/2" water outlet drain   
					Power supply cord   
					3 
				Control Panel Operation   
					Dehumidifying and cooling operation   
					Mode control   
					The operating range for cooling operation is 60°F - 90°F,   
					and the operating range for dehumidifying is 68°F-88°F.   
					The mode control has three settings– Cool, Dehumidify and   
					Fan. The settings are adjusted with the Mode Control button.   
					A light will indicate which setting is currently being used.   
					Power source   
					• The AC socket must be firm and reliable.   
					Cooling operation   
					1. Press MODE button to choose the cooling mode, LCD   
					window will show “cool”.   
					• Don’t connect the portable air conditioner to a multiple socket   
					outlet which is also being used for other electrical appliances.   
					During the cooling operation, always place the air exhaust   
					hose through an open window.   
					• Insert the AC power plug securely into the AC socket before   
					using the unit, when it beeps after two seconds, press ON/   
					OFF button, the unit begins to run.   
					2. Repeatedly press TEMP+ or TEMP- button to set a proper   
					room TEMP. between 60°F - 90°F.   
					LCDI power cord information   
					3. Press FAN SPEED button to choose between low and high   
					speeds.   
					All Friedrich portable air conditioners are shipped from the   
					factory with a Leakage Current Detection Interrupter (LCDI)   
					equipped power cord. The LCDI device meets the UL and   
					NEC requirements for cord connected air conditioners effec-   
					tive August 2004.   
					NOTE:   
					In order to improve the cooling efficiency:   
					a) If your room is directly exposed to the sun, draw the curtains.   
					b) Do not place near other heat source.   
					To test your power supply cord:   
					1. Plug power supply cord into a grounded 3 prong outlet.   
					2. Press RESET (See drawing below).   
					Dehumidifying Operation   
					1. Keep the windows and the doors closed to aid in effectively   
					dehumidifying the room.   
					3. Press TEST (listen for click; Reset button trips and pops out).   
					4. Press and release RESET (listen for click; Reset button   
					latches and remains on). The power supply cord is ready   
					for operation.   
					2. Press MODE button to choose the dehumidifying mode, LCD   
					window will show “DRY”, the fan speed cannot be adjusted.   
					When used as dehumidifier only it is not necessary to install   
					the exhaust hose.   
					NOTE: LCDI device is not intended to be used as a switch.   
					Once plugged in the unit will operate normally without the   
					need to reset the LCDI device.   
					Time Set Function   
					To set the time to start the machine, with the unit off (but power   
					supplied), press TIMER button, the LCD window will show “   
					”, continually press the TIMER button, set the preferred   
					start time. The setting range is 1-24 hours.   
					If the device fails to trip when tested or if the power supply   
					cord is damaged it must be replaced with a new supply cord   
					from the manufacturer. We recommend you contact our Tech-   
					nical Assistance Line at (800) 541-6645. To expedite service,   
					please have your model and serial number available.   
					To set the time to stop the machine, with the unit running,   
					press TIMER button, the LCD window will show “   
					”, con-   
					tinually press the TIMER button ,set the preferred time to stop   
					the machine. The setting range is 1-24 hours   
					WARNING: NEVER   
					CUT OR REMOVE   
					THE GROUNDING   
					PRONG FROM   
					NOTE: During timer mode if the TIMER button is pressed   
					again it will cancel the timer operation.   
					PLUG. NEVER USE   
					EXTENSION CORDS   
					TO OPERATE AN   
					Warning Light   
					Condensed water may accumulate in the unit. If the internal   
					tank becomes full, the Warning Light will come on and the unit   
					will not operate until the unit has been drained.   
					AIR CONDITIONER.   
					Test Button   
					Reset Button   
					4 
				Remote Control Identification and Function   
					Time/Temperature Set Control   
					Used for adjusting the timer and temperature   
					The default display on control panel is room   
					temperature.   
					When the "   
					" or the "   
					" button is pressed   
					in cool mode, the set temperature is displayed   
					and may be adjusted. After 15 seconds the   
					display will revert back to room temperature.   
					Power Control   
					Timer setting is available from 1-24 hours by   
					On/Off   
					pressing the button "   
					" on "   
					".   
					Fan Speed Control   
					Mode Control   
					: HIGH   
					: MED   
					:LOW   
					Press this button to change the operation   
					mode in the order of:   
					Cool → Dry → Fan   
					Farenheit/Celscius Control   
					Press this button to change back   
					and fourth from Farenheit to   
					Celcius temperature readings   
					Timer control   
					In running mode:   
					Auto switch off   
					In standby mode:   
					Auto switch on   
					Press the "   
					" or the "   
					" button to   
					adjust the time setting for 1 hour interval.   
					5 
				Window installation   
					Window adapter kit   
					An installation parts kit is packed with your unit in a separate   
					carton. Before you discard the packaging that your unit came   
					in, please locate the carton that contains these parts and   
					ensure that all parts are present.   
					Window panel extensions   
					Window panel   
					Window panel Attaches to window opening to   
					allow air exchange for system air   
					transfer.   
					Window panel extensions Extends window panel to fit   
					Screws   
					windows of various dimensions.   
					Tube Adapters   
					Tube adapters Connect Air exchange tubes to   
					window panel.   
					Screws 12 screws are included for   
					assembling the window adapter   
					kit. Some screws may be partially   
					assembled onto window panel.   
					Air exchange tubes Exchanges air between the unit   
					and outdoors.   
					Minimum window extension   
					Maximum window extension   
					Minimum hose extension   
					Maximum hose extension   
					26"   
					46"   
					20"   
					60"   
					Air Exchange Tubes   
					Instructions for assembling the window adapter kit   
					Back of   
					window panel   
					1. Insert tube adapters through the back of the window panel.   
					2. Secure each tube adapter with four screws through the   
					front of the window panel.   
					3. Insert window panel extensions into window panel. Lightly   
					tighten the screws in the window panel to hold the   
					extensions in place.   
					Tube Adapters   
					Window Panel   
					Extension screws   
					Window Panel   
					Extension   
					Window Panel   
					6 
				Installing the window adapter kit   
					Note: The window adapter kit must be installed and con-   
					nected for the air conditioner to work properly in Cool mode.   
					The window adapter kit is not required when using the unit   
					in Dehumidify or Fan modes.   
					Your window adapter kit has been designed to fit most stan-   
					dard vertical and horizontal window applications. However,   
					it may be necessary for you to modify some aspects of the   
					installation procedures for certain types of windows.   
					1. Open window.   
					2. Place window panel with extensions into windowframe   
					and adjust to width of window.   
					Window adapter kit may be installed vertically aswell as   
					horizontally. This installaton may also be used for crank   
					style windows.   
					3. Tighten the four screws on the window panel to secure   
					the window panel extensions.   
					4. Close window.   
					5. The window adapter kit should now fit securely within   
					the window frame and you can now attach the air ex-   
					change tubes. If you are having trouble attaching the air   
					exchange tubes, you may attachthe tubes prior to install-   
					ing the window adapter kit.   
					Attaching the air exchange tubes to the air   
					conditioner   
					1. Attach the tubes to the window adapter kit.   
					2. Attach the other end to the air conditioner.   
					To attach air exchange tubes: push tube onto tube adapter   
					and twist until the tab is in place in the hole on the tube.   
					To remove air exchange tubes: twist the end until the tab is   
					clear of the hole in the tube and pull off.   
					Do not attach the tubes if using the unit in dehumidify   
					mode.   
					Maintain a clear distance (from walls, furniture, etc.)   
					of at least 10 inches around the unit to allow proper   
					air circulation and prevent damage to the unit.   
					Important: Do not over-stretch the exhaust tube or-   
					make any unnecessary bends in it.   
					7 
				Condensation Handling   
					Draining Water   
					The water can be drained from the unit by removing the base   
					stopper and letting the water drain by gravity.   
					Your ZoneAire® Portable Air Conditioner is designed to evapo-   
					rate the condensation removed from the interior space through   
					the exhaust hose. Under certain conditions it is possible that   
					the unit will not evaporate 100% of the removed moisture.   
					1. When the WATER FULL lamp is on unplug the unit and move   
					the unit to a suitable location for draining the condensation.   
					The unit is designed with a built-in reservoir to accumulate   
					excess condensate and help dispose of it.   
					2. Using the gravity drain method, ensure that the base stop-   
					per is located above a suitable area for draining the conden-   
					sate and remove the stopper. Re-install the stopper once all   
					water has drained.   
					Internal Water Level   
					1. Under any mode if the water level is in the “low” area the   
					3. Return the unit to the original location and restore power   
					and duct connections.   
					unit will function normally.   
					2. If the water level is in the “normal” area the unit will con-   
					tinue to function normally while internally evaporating the   
					condensate.   
					4. The WATER FULL indicator should be off and the unit will   
					return to normal operating mode.   
					3. If the unit cannot evaporate all of the condensate internally,   
					the tank may become full. If the tank becomes full, the unit   
					will turn off, and the Water Full light will illuminate.   
					Permanent Drainage   
					For permanent and continuous drainage, a 1/2" hose may be   
					attached to the unit and led down a drain.   
					Drain Valve   
					8 
				Maintenance /Service   
					WARNING   
					• 
					• 
					Disconnect the power before cleaning.   
					! 
					Make sure there is no power to the unit before   
					beginning to maintain or repair the unit in order   
					to prevent accidents caused by electrical shock.   
					Cleaning the air filter   
					If the air filter is blocked with a lot of dust, the air flow volume   
					will be reduced. Clean the filter once every two weeks.   
					Open and clean the air filter:   
					1. Pull the filter out as shown in the drawing.   
					2. Take out the air filter from the filter cover.   
					3. Wash the air filter by immersing it gently into warm (about   
					40°C or 104°F) water with a neutral detergent or vacuum   
					the filter clean.   
					4. Rinse the filter and dry it thoroughly in a shaded place.   
					5. Install the air filter back to its original place.   
					Cleaning the air conditioner   
					Clean the surface of the unit with a damp cloth, then dry using   
					a duster or similar.   
					Preparation for storage   
					1. Turn off the air conditioner, disconnect the power.   
					2. Perform proper maintenance to the air filter and other parts.   
					CAUTION   
					! 
					3. Open the base stopper to drain out all of the water from the   
					base. Operating the unit in fan only mode for 12 hours will   
					help ensure there is no moisture within the unit.   
					Do not use chemical solvent (like benzene or alcohol) to clean the   
					surface of the unit. If you do so, the surface may be scratched,   
					damaged or even cause the case to become deformed.   
					4. Cover the unit to prevent dust or filth from entering the unit.   
					Prior to operating seasons   
					1. Check to ensure that the air inlets and outlets of the unit   
					Drain valve   
					are not blocked.   
					2. Make sure that air filter is properly in place before operat-   
					ing the machine. If the machine is operated with air filter   
					removed, dust and foreign objects will result in faulty per-   
					formance of the air conditioner.   
					CAUTION   
					WARNING   
					Power Sources   
					! 
					! 
					Safety Precautions   
					• Do not use a damaged or improper AC socket.   
					• Make sure the unit is installed in an accessible location.   
					• When unplugging the unit, hold the power plug securely   
					and pull it out carefully.   
					• Do not locate the unit in direct sunlight so as to avoid discol-   
					oration of the plastic.   
					• Never use an extension cord with this air conditioner.   
					• Do not use the unit in water or near water to avoid electrical   
					shock.   
					Other Warnings   
					• Keep the unit one meter away from TV sets or radios to   
					avoid the risk of electromagnetic interference.   
					• Do not use near gas appliances, fires or in the vicinity of   
					flammable liquids.   
					• Only operate the unit in the appropriate upright position.   
					• Ensure that the discharge air outlet is free from obstruc-   
					tions and not impeded by walls or other structures.   
					9 
				Troubleshooting   
					Before seeking repair or service, please check the following first:   
					Trouble   
					Check   
					Action   
					Is there power?   
					Is it plugged in?   
					Is the fuse or circuit breaker switch off?   
					Is timer on?   
					Push the plug into the wall socket   
					Change the fuse or reset breaker   
					Pres TIMER button   
					Air conditioner does   
					not operate   
					Is air inlet or outlet blocked?   
					Is there any other heat source in the room?   
					Are air filters dirty?   
					Clear the air path   
					Move the unit away from heat source   
					Clean the air filter   
					Set to a suitable temperature   
					Set to a suitable fan speed   
					The sound may be normal   
					Move unit to a level location   
					Cooling efficiency   
					is not good   
					Is SET TEMP suitable?   
					Is indoor fan speed set at low?   
					Is the sound part of the refrigeration cycle?   
					Is unit leveled?   
					Too much noise and   
					vibration   
					Is the voltage of the power source correct and continuous? Repair the power source   
					Is the air exhaust bent? Try to keep the air exhaust horizontal   
					The machine starts   
					and stops frequently   
					WARNING   
					In case of major malfunction, disconnect power immediately and call for service.   
					! 
					10   
				Friedrich Air Conditioning Company   
					P.O. Box 1540   
					San Antonio, TX 78295   
					210.357.4400   
					
					PORTABLE AIR CONDITIONERS   
					LIMITED WARRANTY   
					FIRST YEAR   
					ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from   
					date of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich   
					Authorized Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly   
					agreed to be the exclusive remedy within twelve months from the date of the original purchase.   
					SECOND THROUGH FIFTH YEAR   
					SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser   
					coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in   
					your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase,   
					FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will   
					not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the   
					Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the   
					sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the   
					original purchase.   
					APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District   
					of Columbia, and Canada. This warranty is not applicable to:   
					1. Air filters or fuses.   
					2. Products on which the model and serial numbers have been removed.   
					3. Products which have defects or damage which results from improper installation, wiring, electrical current   
					characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication   
					of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war,   
					government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.   
					OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service   
					Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write   
					to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.   
					LIMITATIONS:   
					THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty   
					notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY   
					SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND   
					EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR   
					IMPLIED WARRANTY.   
					NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of   
					consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.   
					OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.   
					PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.   
					All service calls for explaining the operation of this product will be the sole responsibility of the consumer.   
					All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to   
					repairs being made.   
					11   
				Friedrich Air Conditioning Co.   
					Post Office Box 1540 • San Antonio, Texas 78295-1540   
					4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212   
					(210) 357-4400 • FAX (210) 357-4480   
					
					PAC-IO (10-07)   
				 |