Friedrich MR36Y3F User Manual

SPLIT TYPE  
ROOM AIR CONDITIONER  
CEILING TYPE (60Hz)  
Indoor unit Outdoor unit  
MS36Y3F MR36Y3F  
CONTENTS  
SPECIFICATIONS . . . . . . . . . . . . . . . . . .  
OUTLINE AND DIMENSIONS . . . . . . . . .  
REFRIGERANT SYSTEM DIAGRAM. . . .  
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .  
INDOOR PCB CIRCUIT DIAGRAM . . . . .  
OUTDOOR PCB CIRCUIT DIAGRAM . . .  
1
2
4
5
7
8
ERROR CONTENTS . . . . . . . . . . . . . . .11  
DISASSEMBLY ILLUSTRATION . . . . . .13  
PARTS LIST. . . . . . . . . . . . . . . . . . . . . .21  
ACCESSORIES . . . . . . . . . . . . . . . . . . . 23  
OUTLINE AND DIMENSIONS  
INDOOR UNIT  
Unit : inch (mm)  
65-1/2" (1,660)  
9-1/2"  
(240)  
63" (1,600)  
2006.02.28  
2
OUTDOOR UNIT  
Unit : inch (mm)  
1-1/4"  
(31)  
1/2"  
(12)  
3"(77)  
13" (330)  
35-1/2" (900)  
15-3/4" (400)  
Air Flow  
25-5/8" (650)  
5-3/4" (147)  
6-3/4" (170)  
2006.02.28  
3
REFRIGERANT  
SYSTEM DIAGRAM  
OUTDOOR UNIT  
INDOOR UNIT  
Pressure  
Check Valve  
Refrigerant Pipe  
15.88mm (5/8")  
High Pressure  
Switch  
Charging  
Valve  
4-way  
Valve  
Muffler  
Evaporator  
Condenser  
Accumulator  
Compressor  
Expansion  
Valve  
Refrigerant Pipe  
9.52mm (3/8")  
Strainer  
Strainer  
Charging Valve  
: COOL  
: HEAT  
2006.02.28  
4
CIRCUIT DIAGRAM  
INDOOR UNIT  
ROOM THERMISTOR  
PIPE THERMISTOR  
1 2  
1 2  
CN6 CN7  
1 2  
1 2  
CN8  
1
2
3
FAN MOTOR  
CAPACITOR  
WHITE  
WHITE  
1
2
CN201  
BROWN  
RED  
ORANGE  
YELLOW  
WHITE  
BLUE  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
BROWN  
RED  
ORANGE  
YELLOW  
WHITE  
1
2
3
4
5
1
2
3
4
5
STEP MOTOR  
( UP / DOWN )  
M
M
PURPLE  
GRAY  
GRAY  
PURPLE  
BLUE  
1
2
3
1
2
3
BROWN  
RED  
ORANGE  
YELLOW  
WHITE  
1
2
3
4
5
1
2
3
4
5
FAN MOTOR  
F M  
STEP MOTOR  
( LEFT / RIGHT )  
BLACK  
WHITE  
RED  
2
1
3
1
2
3
CN17  
3 2  
CN1  
3 2  
1
1
Use T 3.15A-250V  
Fuse on F101  
POWER SUPPLY PCB  
GREEN  
G
3
2
1
3
2
1
TERMINAL  
2006.02.28  
5
OUTDOOR UNIT  
OUTDOOR THERMISTOR  
COMPRESSOR THERMISTOR  
HEAT SINK THERMISTOR  
BLUE  
BLACK  
PIPE THERMISTOR  
BROWN  
BROWN  
DISCHARGE THERMISTOR  
BLACK  
1
2
1
2
1
2
1
2
1
2
EMI FILTER  
RED1T  
CN21 CN22 CN23  
CN25  
CN26  
CONNECTOR  
RED  
COMPRESSOR  
RED  
RED  
U
1
2
CN37  
CN30  
HIGH PRESSURE SWITCH  
W305  
U
V
W304  
WHITE  
WHITE  
V
FUSE  
F4 T 5A-250V  
SOLENOID COIL  
BLACK  
BLACK  
1
2
3
W
W
W303  
BLACK  
BLACK  
4WV  
BROWN  
RED  
ORANGE  
ACTIVE  
1
2
3
4
5
6
1
2
3
4
5
FILTER  
RED  
CN407  
FAN MOTOR  
1
2
3
4
5
6
MODULE  
TERMINAL  
BLACK  
WHITE  
YELLOW  
BLUE  
YELLOW  
F M  
CN802  
BLACK  
WHITE  
L1  
YELLOW  
CONTROLLER  
PCB ASSY  
P
N
W12  
W13  
BLUE  
BLACK  
BROWN  
L2  
+
EMI FILTER  
2T  
-
CHOKE COIL  
RED  
BROWN  
BLUE  
ORANGE  
YELLOW  
WHITE  
ORANGE  
FUSE  
1
2
3
4
5
6
EXPANSION VALVE COIL  
E V  
W21  
W22  
ORANGE  
F2 T 3.15A-250V  
CN27  
RED  
W16  
W17  
BLACK  
W10  
W11  
POSISTOR  
CN1  
CN34  
W200  
1
2
3
3 4  
1
2
WHITE  
BLACK  
2
CN1  
1
3
TM102  
W9 W8  
POWER SUPPLY PCB ASSY  
TM101 W3  
W7  
W1 W2  
W6  
RED  
G
1
2(N) 3  
L
N
G
EARTH  
EARTH  
2006.02.28  
6
ERROR CONTENTS  
(Indoor unit)  
Operation can be checked by lighting and flashing of the display section OPERATION,  
TIMER, and VERTICAL SWING lamps.  
Perform judgment in accordance with the following.  
VERTICAL SWING lamp (Orange)  
TIMER lamp (Green)  
OPERATION lamp (Red)  
MANUAL  
AUTO  
SWING SWING TIMER OERATION  
TEST RUNNING  
When the air conditioner is run by pressing the remote control unit test run button, the  
OPERATION, TIMER, and VERTICAL SWING lamps flash slowly at the same time.  
ERROR  
The OPERATION, TIMER, and VERTICAL SWING lamps operate as follows  
according to the error contents.  
OPERATION TIMER lamp SWING lamp  
Error contents  
lamp (RED)  
(GREEN)  
(ORANGE)  
Indoor EEPROM abnormal  
Outdoor EEPROM abnormal  
(2 times)  
(2 times)  
(3 times)  
(3 times)  
(4 times)  
(5 times)  
(5 times)  
(6 times)  
Indoor room temperature sensor open  
Indoor room temperature sensor shortcircuited  
Indoor heat exchanger temperature sensor open  
Indoor heat exchanger temperature sensor shortcircuited  
Float switch operated  
Indoor signal abnormal  
Outdoor signal abnormal  
Indoor fan abnormal  
(2 times)  
(3 times)  
(3 times)  
(4 times)  
(4 times)  
Outdoor power source connection abnormal  
Outdoor heat exchanger temperature sensor open  
Outdoor heat exchanger temperature sensor shortcircuited  
Outdoor temperature sensor open  
Outdoor temperature sensor shortcircuited  
Outdoor discharge pipe temperature sensor or compressor  
temperature sensor open  
(5 times)  
Outdoor discharge pipe temperature sensor or compressor  
temperature sensor shortcircuited  
(5 times)  
(6 times)  
(7 times)  
Outdoor high pressure abnormal  
Outdoor discharge pipe temperature or compressor  
temperature sensor abnormal  
: 0.1s ON/0.1s OFF (flash)  
: 0.5s ON/0.5s OFF (flash)  
: OFF  
2006.03.13  
11  
ERROR CONTENTS  
(outdoor unit)  
1. Make a TEST RUN in accordance with the in-  
stallation instruction sheet for the indoor unit.  
2. When the product is operating:  
1
Press the PUMP DOWN switch on the outdoor unit.  
The LED on the outdoor unit circuit board lights, and  
operation stops. At this point, recovery has not been  
completed, so do not close the two- and three-way  
valves.  
2. OUTDOOR UNIT LEDS  
When a malfunction occurs in the outdoor unit, the LED on  
the circuit board lights to indicate the error. Refer to the fol-  
lowing table for the description of each error according to the  
LED.  
2
3
4
The pump down operation (cooling operation) be-  
gins after three minutes. Close the three-way valve  
(liquid) after operation starts.  
LED  
Error contents  
Communication error  
After 2 - 3 minutes, operation stops. Close the three-  
way valve (gas) within one minute after operations  
stops.  
1 flash  
(Indoor unit - Outdoor unit)  
2 flash Discharg pipe temperature sensor  
3 flash Outdoor heat exchanger temperature sensor  
4 flash Outdoor temperature sensor  
7 flash Compressor temperature sensor  
8 flash Heat sink temperature sensor  
9 flash Pressure switch abnormal  
The LED will go out three minutes after it stops. Dis-  
connect the power supply after confirming that the  
LED has gone out.  
*When the pump down operation is repeated, temporarily disconnect  
the power supply after opening the closed valves (both liquid and gas).  
Reconnect the power supply after 2 - 3 minutes and perform the pump  
down operation.  
12 flash IPM error  
*When the start of the operation after pump down operation has been  
completed, temporarily disconnect the power supply after opening the  
closed valves (both liquid and gas).  
Reconnect the power supply after 2-3 minutes and be sure to perform  
a test operation for cooling.  
13 flash Compressor rotor position cannot detect  
14 flash Compressor cannot operate  
15 flash Outdoor fan abnormal (upper fan)  
16 flash Outdoor fan abnormal (lower fan)  
3-way valve  
(Liquid)  
lighting  
No error  
SPECIAL INSTALLATION  
SETTING  
PUMP DOWN (Refrigerant collecting operation)  
3-way valve  
(Gas)  
Perform the following procedures to collect the refrigerant  
when moving the indoor unit or the outdoor unit.  
1. When the product is stopped:  
PUMP DOWN SW  
1
Press the PUMP DOWN switch on the outdoor unit.  
(The LED on the outdoor unit circuit board lights.)  
2
The pump down operation (cooling operation) be-  
gins right away. After oparation starts, close the  
three-way valve (liquid).  
3
4
After 2 - 3 minutes, operation stops. Close the three-  
way valve (gas) within one minute after operations  
stops.  
The LED will go out three minutes after it stops.Dis-  
connect the power supply after confirming that the  
LED has gone out.  
DANGER  
This part (Choke coil) generates high voltages.  
Never touch this part.  
2006.02.28  
12  
DISASSEMBLY ILLUSTRATION  
INDOOR UNIT  
Model : MS36Y3F  
2006.02.28  
13  
Model : MS36Y3F  
506  
407  
505  
408  
69  
435  
434  
876-1  
386  
361  
160  
91  
387  
91  
321  
91  
2006.02.28  
14  
Model : MS36Y3F  
321  
63  
387  
436  
385  
424  
438  
868  
684  
763  
876-2  
227  
2006.02.28  
15  
Model : MS36Y3F  
195  
34  
253-5  
253-3  
253-4  
253-6  
195  
253-7  
253-2  
253-1  
236  
234  
875  
380  
185-1  
625  
381-4  
187  
815-1  
472  
223  
448  
2006.02.28  
16  
Model : MR36Y3F  
1
6
4
7
3
2
5
2006.02.28  
17  
Model : MR36Y3F  
10  
13  
9
17  
18  
15  
14  
8
2006.02.28  
18  
Model : MR36Y3F  
26  
24  
25  
31  
27  
22  
23  
19  
29  
28  
12  
12  
30  
20  
2006.02.28  
19  
Model : MR36Y3F  
38  
37  
36  
35  
33 34  
2006.02.28  
20  
PARTS LIST  
INDOOR UNIT  
Ref. Description  
Part No.  
Ref. Description  
Part No.  
8
12  
34  
56  
63  
69  
74  
91  
109  
122  
Air Filter  
Base Assy  
Capacitor  
Sirocco Fan Assy  
Panel (Front)  
Louver  
Intake Grille  
Hinge  
9359739005  
9359680000  
9900270216  
9359701002  
9359734000  
9359719007  
9359738008  
9359699002  
9359704003  
9357921006  
345-1 Filter Guide-R  
345-2 Filter Guide-L  
9359692003  
9359693000  
9359733003  
9359694007  
313209391403  
0600118075  
9359744009  
9359745006  
9359707004  
9702260019  
361  
379  
380  
Bushing  
Hinge Plate (Grille)  
Locking Spacer KGLS-6S  
381-4 Spacer  
382  
383  
384  
385  
Cover (Decoration)-R  
Cover (Decoration)-L  
Shaft  
Casing  
Bearing-B Assy  
Indicator PCB Assy  
126  
138  
146  
160  
164  
174  
181  
Bracket (Motor)  
Separate Wall  
Evaporator Assy  
Drain Pan Sub Assy  
Fan Motor Assy-IN  
Hanger  
9359681007  
9359700005  
9371073040  
9360429018  
9360457004  
9359742005  
9359691006  
9357376004  
313361271706  
313361275805  
386  
387  
388  
396  
403  
407  
408  
424  
434  
435  
Panel Left Assy  
Kit (Panel Right Assy)  
Joint Assy  
Rfm Bracket Metal  
Fixture (Bearing)  
Rod (Motor)  
Link (Louver)  
Sector Gear  
Base (Louver)  
Louver Spring  
9359685005  
9371361017  
9359706007  
9359697008  
9359687009  
9359723004  
9359726005  
9359729006  
9359718000  
9359720003  
Hole Cover  
185-1 Rubber Bushing  
187  
195  
Clamp No.1219  
Clamp SKB-100  
223  
227  
228  
229  
234  
236  
Control Box Assy  
9362025003  
9359735076  
9359721000  
9359722007  
9703299025  
9705914285  
(K01AL-050RHSE-C1)  
9371190051  
9359690009  
9359689003  
436  
438  
448  
472  
505  
506  
580  
625  
684  
735  
Flap Spring  
Pinion Gear  
9359730002  
9359728009  
9359713005  
9359712008  
9359724001  
9359725008  
9359737001  
9359240006  
9359727002  
9360455000  
Badge "FRIEDRICH"  
Insulation (Louver)-R  
Insulation (Louver)-L  
Thermistor (Room)  
Controller PCB Assy  
Control Box-B  
Control Box-A  
Stopper (Louver)  
Rod (Louver)  
Cover (Top)  
Cord Bushing  
Motor Base  
240  
Remote Control Unit  
240-1 Cover Panel (Pipe)-L  
240-2 Cover Panel (Pipe)-R  
Distributor Assy  
253-1 Wire Assy (Terminal)  
253-2 Wire Assy (Terminal)  
253-3 Wire Assembly  
253-4 Wire Assy (Connector)  
253-5 Wire Assy (Connector)  
253-6 Wire Assy (Connector)  
253-7 Wire Assy (Connector)  
9702321017  
9702322014  
9702311018  
9702323011  
9702319014  
9702317010  
9702318017  
9359686002  
9359731009  
9373038214  
743  
752  
755  
761  
762  
763  
Remote Control Holder Case  
Bracket Panel (Pipe)  
Cover (Casing)  
Kit (Cover Side-R)  
Kit (Cover Side-L)  
Cover (Receiver)  
9305642014  
9359688006  
9359705000  
9371364018  
9371365015  
9359714002  
9703403019  
9359736004  
9704561350  
9360479013  
815-1 Terminal-7P  
868  
875  
286  
321  
329  
Bracket (Bearing)  
Flap Assy  
Coupling Pipe Assy  
PCB Holder  
Power Supply PCB Assy  
876-1 Motor, Step-H  
338-1 Fixture (Motor)  
338-2 Fixture (Motor)-B  
9359702009  
9359703006  
876-2 Motor, Step  
9900362010  
9900022020  
---  
Thermistor (Pipe)  
2006.02.28  
21  
OUTDOOR UNIT  
Ref.  
Description  
Part No.  
1
2
3
4
5
6
7
8
Top Panel Sub Assy  
Front Panel  
9374417025  
9374094066  
9374330010  
9374173013  
9374415038  
9374416073  
9375212025  
9366378020  
Fan Guard  
Grip Side  
Service Panel Sub Assy  
Right Panel Sub Assy  
LABEL (FRIEDRICH)  
Propeller Fan Assy  
9
10  
Motor, Induction  
Condenser-A Assy  
9602114016  
9374433148  
12  
13  
14  
15  
17  
Strainer Assy  
Separate Wall Assy  
Cap Foot  
9372524015  
9375226015  
9374345014  
9374166183  
9372205044  
Base Assy  
3-Way Valve Assy  
18  
19  
20  
22  
23  
24  
25  
26  
3-Way Valve Assy  
Check Joint Assy  
Compressor Assy  
4-Way Valve  
9372205075  
9372802038  
9373711018  
9900164010  
9900165055  
9900186012  
9373461067  
9373463054  
Solenoid  
Pressure Switch  
Inlet Pipe Cond A Assy  
Inlet Pipe Cond B Assy  
27  
28  
29  
30  
31  
33  
34  
35  
Outlet Pipe Cond A Assy  
Expansion Valve Assy  
Coil (Expansion Valve)  
Distributor  
Discharge Pipe A Assy  
Terminal 2P  
9374266050  
9370947113  
9900057039  
9369128004  
9372264140  
9701971015  
9900203023  
9703457012  
Terminal 5P  
ACTPM  
36  
37  
38  
----  
Holder Thermo  
9372797013  
9705642102  
9705647053  
0600239534  
Inverter PCB Assy  
Power PCB Assy  
Fuse 3.15A-250V  
----  
----  
----  
Thermistor (Outdoor Temp.) 9900378035  
Heat Exchanger Thermistor 9900374013  
Thermistor (Discharge)  
9704219114  
----  
----  
----  
----  
----  
----  
----  
----  
Compressor Thermistor  
Thermistor  
Heatsink Thermistor  
Transformer  
Varistor  
9900156022  
9704265012  
9900311018  
9702334024  
0000361224  
0600280147  
9900117016  
9900007010  
Arrester  
Relay  
Relay  
----  
----  
----  
Switch Push  
Switch Slide  
Drain Pipe Assy  
9703476013  
9701392018  
9303029015  
----  
Drain Cap  
313166024302  
2006.02.28  
22  
ACCESSORIES  
INDOOR UNIT  
Name and Shape  
Q'ty  
Application  
Name and Shape  
Q'ty  
Application  
Remote  
control  
Use for air conditioner  
operation  
Coupler heat insulator (large)  
For indoor side pipe joint  
(Gas pipe)  
2
1
Coupler heat insulator (small)  
Nylon fastener  
For indoor side pipe joint  
(Liquid pipe)  
1
Battery (penlight)  
For remote control unit  
2
1
Large  
4
Small  
4
For fixing the coupler heat  
insulator  
Remote control  
unit holder  
For mounting the remote  
control unit  
Special nut A  
(large flange)  
For installing indoor unit  
For installing indoor unit  
4
4
1
Special nut B  
(small flange)  
Tapping screw  
(ø3 x 12)  
For remote control unit  
holder installation  
2
1
1
For positioning the indoor  
unit  
Installation  
template  
Drain hose insulation  
VT wire  
Adhesive type 70 x 230  
For connecting the piping  
Auxiliary pipe assembly  
For fixing the drain hose  
L 280 mm  
1
OUTDOOR UNIT  
Name and Shape  
Q'ty  
Application  
OPTIONAL PARTS  
The following options are available.  
Drain pipe  
1
DRAIN PUMP UNIT : UTR-DPB241 (P/N 9034087001)  
For outdoor unit drain  
piping work (May not be  
supplied, depending on  
the model.)  
WIRED REMOTE CONTROLLER UNIT : UTB-UUB(P/N 9075887004)  
Drain cap  
5
2006.02.28  
23  
0602G3034  

Actron Compression Tester CP7821 User Manual
Bosch Appliances Air Conditioner NDA FMT200 DOME User Manual
Brother Fax Machine MFC J425W User Manual
Carrier 38CKC042 Air User Manual
Danby DAC5110M User Manual
Friedrich Air Conditioner CP10A10 User Manual
Havis Shields Telescoping Computer Base Lock C TCB LOCK User Manual
Hitachi RAS 51CHA3 User Manual
HP Hewlett Packard OFFICEJET 7400 User Manual
Human Touch Automobile Accessories HT 450 User Manual