PRODUCT DATASHEET
Asia Pacific Region
+852-31026623
ENERGIZER E10HH
Zinc Air
Specially designed for use in humid climatic conditions.
Specifications
Chemical System:
Tab Color:
Designation:
Zinc Air (ZnO2)
Yellow
IEC-PR70
Nominal Voltage:
Typical Capacity:
1.4 Volts
91 mAh (to 0.9 volts)
(top view) (bottom view)
(Rated at 3k ohms at 21°C/65% RH)
Industry Standard Dimensions
Typical Weight:
Typical Volume:
0.32 grams
0.08 cubic centimeters
(millimeters)
Impedance
The total opposition that a battery offers to the flow of alternating
current. Impedance is a combination of resistance and reactance.
0.25
Minimum
3.18
3.00
The typical impedance of these cells on open circuit and during
useful discharge varies from 5-20 ohms. This applies over a
frequency range of 40-5,000 hertz at the current drains shown
below.
3.60
3.30
1.35R
Typical
0.015
Typical Coining Depth
5.80
5.60
Impedance vs. Frequency
35
00% DoD
25% DoD
50% DoD
80% DoD
30
25
20
15
10
5
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
0.43 & 0.22 milliamperes
Load: 3K & 6K ohms
1.4
1.3
1.2
1.1
1.0
0.9
0
0.1
1
10
100
1000
10000
100000
Frequency (Hz)
Impedance vs. Depth of Discharge
25
20
15
10
5
3K
6K
0.8
0
50 100 150 200 250 300 350 400 450
Service, Hours
Simulated Application Test
40 Hz
1K Hz
Typical Performance at 21°C & 50% RH
Schedule:
Typical Drains:
at 1.3V
(milliamperes)
Load
Cutoff
0.9V
(hours)
(ohms)
0
0%
10%
20%
30% 40%
50% 60%
70%
80% 90% 100%
16 Hours/Day
16 Hours/Day
0.43
0.22
3,000
6,000
211
414
Depth of Discharge
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 8953AP
Page 1 of 1
|