EMI DWPH365 WHP36 SHC36 User Manual

DWPH365 (WHP36-SHC36)  
Rev. 1.1 [12/04]  
JOB NAME: _____________________________________ LOCATION: _______________________________________  
PURCHASER: _____________________________________________________________________________________  
ENGINEER:_______________________________________________________________________________________  
SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]  
SUBMITTED BY: _________________________________ DATE: ___________________________________________  
UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________  
CAPACITIES:  
Cooling  
33,000 Btu  
31,000 Btu  
18,200 Btu  
Heating  
– High  
– Low  
571/2  
Indoor Design Temp ºF  
Cooling  
Heating  
DB/WB  
80/67  
70/57  
Outdoor Design Temp ºF DB/WB  
Cooling  
Heating  
95/75  
47/43  
17/15  
17  
– High  
– Low  
EER  
SEER  
HSPF  
10.0  
10.0  
6.8  
111/4  
INDOOR UNIT:  
Power Supply  
Max. Fuse Size  
Min. Ampacity  
Max. Fuse Size  
Min. Ampacity  
Sound  
208/230/1/60  
15 Amps (w/o electric heat)  
.70 Amps (w/o electric heat)  
30 Amps (w/5kw electric heat)  
27.9 Amps (w/5kw electric heat)  
54 dBa  
115 Lbs  
Weight  
OUTDOOR UNIT:  
Power Supply  
Max. Fuse Size  
Min. Ampacity  
Sound  
208/230/1/60  
30 Amps  
19.8 Amps  
67.2 dBa  
155 Lbs  
Weight  
REFRIGERANT PIPING:  
Max. Lift  
35 Ft  
Max. Length  
100 Ft  
3/8 In  
7/8 In  
Liquid (OD)  
Suction (OD)  
STANDARD FEATURES:  
• Five-Year Compressor/One-Year Parts Warranty  
• I/R Unit Mount Control (w/optional hand-held control)  
• Dry Mode for humidity control (when optional electric heat is ordered)  
• Auto Restart following a power outage  
• Anti-Short Cycle protection  
• Freeze Protection  
Test Operation  
• Side Discharge/Low Profile Condenser  
• Fan Purge  
• Manual Reset High Pressure Switch  
Enviromaster International LLC  
Rome, New York, USA  
EMI ENGINEERING SUBMITTAL DWPH365 (WHP36-SHC36)  
are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan  
speed according to heating or cooling demand; dry mode operates cooling and electric heat simultaneously to remove  
humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all timers  
are eliminated); non-volatile back-up memory, control settings are maintained for an indefinite period during a power  
outage, when power is restored the equipment will resume operation after a three-minute compressor time delay;  
optional hand held infra-red controller. The control voltage between the indoor unit and the outdoor unit shall be 24  
Volts A.C. The 24 Volts shall be generated from the indoor unit’s 24 Volt 40VA transformer.  
PART SIX “OUTDOOR UNIT”  
The outdoor unit shall be completely factory assembled, piped and wired. The cabinet shall be fabricated of G60  
galvannealed steel, finished in “off-white” with corrosion inhibiting polyester powder-coated paint. The unit shall be  
furnished with one (1) direct drive, propeller type fan arranged for horizontal discharge. The motor shall have inherent  
protection, be of the permanently lubricated type, and resiliently mounted for quiet operation. The fan shall be provided  
with a guard to prevent contact with moving parts. The compressor shall be of the high-performance reciprocating type  
with an internal thermal overload. The compressor shall be mounted so as to avoid the transmission of vibration. The  
refrigeration system shall be equipped with high pressure switch and have the capability to operate with a maximum  
height difference of 35 feet and overall refrigerant tubing length of 100 feet between indoor and outdoor sections  
without the need for line size changes or additional oil. The condenser coil shall be of nonferrous construction with  
louvered fins bonded to rifled copper tubing. The unit shall be controlled by the microprocessor located in the indoor  
matching unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of  
satisfactory operation within voltage limits of 208/230 Volts +/- 10%. Heating expansion is controlled by a TXV in  
the outdoor unit.  
PART SEVEN “OPTIONAL EQUIPMENT”  
• Hand Held Infrared Remote Controller – used to command the unit-mounted controls.  
• 24V Wall Thermostat Control – anti-short cycle compressor protection; fan purge, fan remains on for 60 seconds  
after heat/cool call is dropped for improved efficiency; integral heating relay ensures that the fan operates whenever  
electric heat is energized; two stage heating capable when matched up with an EMI heat pump and an appropriate  
two stage thermostat.  
• 5KW Electric Heat – shall be factory installed; automatic reset high temperature cutout and redundant high  
temperature fuse link.  
• Internal Condensate Pump – shall be field installed or factory installed and shall have 4 ft of head.  
• Low Ambient Control – shall consist of a fan cycle switch and a lock-out relay, field installed.  
• Hard Start – shall be field installed.  
• Sea Coast Style Coated Coils – shall be factory installed; coating shall protect against corrosion due to acids,  
solvents and salt.  
5780 Success Drive, Rome, NY 13440  
Phone: 1-800-228-9364  
FAX: 1-800-232-9364  
Enviromaster International LLC  
Rome, New York, USA  

Amcor 000E AL 10 User Manual
Black Decker Univolt 98014 User Manual
Brother USUARIO MFC J415W User Manual
Canon PIXMA MP990 Multifunction Photo Printer 3749B002 User Manual
Canon Printer H12 4605 User Manual
Carrier 48EY024 068 User Manual
Cornelius Flavorfusion TP01070 User Manual
Fujitsu Air Conditioner AOU24CXQ User Manual
Hitachi UC 18YG User Manual
HP Hewlett Packard PHOTOSMART WIRELESS B109 User Manual