DWPH365 (WHP36-SHC36)
Rev. 1.1 [12/04]
JOB NAME: _____________________________________ LOCATION: _______________________________________
PURCHASER: _____________________________________________________________________________________
ENGINEER:_______________________________________________________________________________________
SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]
SUBMITTED BY: _________________________________ DATE: ___________________________________________
UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________
CAPACITIES:
Cooling
33,000 Btu
31,000 Btu
18,200 Btu
Heating
– High
– Low
571/2
”
Indoor Design Temp ºF
Cooling
Heating
DB/WB
80/67
70/57
Outdoor Design Temp ºF DB/WB
Cooling
Heating
95/75
47/43
17/15
”
17
– High
– Low
EER
SEER
HSPF
10.0
10.0
6.8
111/4
”
INDOOR UNIT:
Power Supply
Max. Fuse Size
Min. Ampacity
Max. Fuse Size
Min. Ampacity
Sound
208/230/1/60
15 Amps (w/o electric heat)
.70 Amps (w/o electric heat)
30 Amps (w/5kw electric heat)
27.9 Amps (w/5kw electric heat)
54 dBa
115 Lbs
Weight
OUTDOOR UNIT:
Power Supply
Max. Fuse Size
Min. Ampacity
Sound
208/230/1/60
30 Amps
19.8 Amps
67.2 dBa
155 Lbs
Weight
REFRIGERANT PIPING:
Max. Lift
35 Ft
Max. Length
100 Ft
3/8 In
7/8 In
Liquid (OD)
Suction (OD)
STANDARD FEATURES:
• Five-Year Compressor/One-Year Parts Warranty
• I/R Unit Mount Control (w/optional hand-held control)
• Dry Mode for humidity control (when optional electric heat is ordered)
• Auto Restart following a power outage
• Anti-Short Cycle protection
• Freeze Protection
• Test Operation
• Side Discharge/Low Profile Condenser
• Fan Purge
• Manual Reset High Pressure Switch
Enviromaster International LLC
Rome, New York, USA
EMI ENGINEERING SUBMITTAL DWPH365 (WHP36-SHC36)
are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan
speed according to heating or cooling demand; dry mode operates cooling and electric heat simultaneously to remove
humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all timers
are eliminated); non-volatile back-up memory, control settings are maintained for an indefinite period during a power
outage, when power is restored the equipment will resume operation after a three-minute compressor time delay;
optional hand held infra-red controller. The control voltage between the indoor unit and the outdoor unit shall be 24
Volts A.C. The 24 Volts shall be generated from the indoor unit’s 24 Volt 40VA transformer.
PART SIX “OUTDOOR UNIT”
The outdoor unit shall be completely factory assembled, piped and wired. The cabinet shall be fabricated of G60
galvannealed steel, finished in “off-white” with corrosion inhibiting polyester powder-coated paint. The unit shall be
furnished with one (1) direct drive, propeller type fan arranged for horizontal discharge. The motor shall have inherent
protection, be of the permanently lubricated type, and resiliently mounted for quiet operation. The fan shall be provided
with a guard to prevent contact with moving parts. The compressor shall be of the high-performance reciprocating type
with an internal thermal overload. The compressor shall be mounted so as to avoid the transmission of vibration. The
refrigeration system shall be equipped with high pressure switch and have the capability to operate with a maximum
height difference of 35 feet and overall refrigerant tubing length of 100 feet between indoor and outdoor sections
without the need for line size changes or additional oil. The condenser coil shall be of nonferrous construction with
louvered fins bonded to rifled copper tubing. The unit shall be controlled by the microprocessor located in the indoor
matching unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of
satisfactory operation within voltage limits of 208/230 Volts +/- 10%. Heating expansion is controlled by a TXV in
the outdoor unit.
PART SEVEN “OPTIONAL EQUIPMENT”
• Hand Held Infrared Remote Controller – used to command the unit-mounted controls.
• 24V Wall Thermostat Control – anti-short cycle compressor protection; fan purge, fan remains on for 60 seconds
after heat/cool call is dropped for improved efficiency; integral heating relay ensures that the fan operates whenever
electric heat is energized; two stage heating capable when matched up with an EMI heat pump and an appropriate
two stage thermostat.
• 5KW Electric Heat – shall be factory installed; automatic reset high temperature cutout and redundant high
temperature fuse link.
• Internal Condensate Pump – shall be field installed or factory installed and shall have 4 ft of head.
• Low Ambient Control – shall consist of a fan cycle switch and a lock-out relay, field installed.
• Hard Start – shall be field installed.
• Sea Coast Style Coated Coils – shall be factory installed; coating shall protect against corrosion due to acids,
solvents and salt.