Daewoo DSB F154LH User Manual

OWNER'S MANUAL  
MODEL #:  
DSB-F154LH  
S1  
S/N : 3113909901  
LOCATION OF CONTROLS  
INDOOR UNIT  
Electric Dust Collector  
(Air clean Plasma)  
Removes small dust and  
generates (-) ions.  
Emergency/  
Remote Switch  
Slide to select  
Deodorizing Filter  
the desired position.  
Removes bad  
smells from the air.  
Air In  
O2  
Hose Cover (AH Model Only)  
Sensor Wire  
(LH/PH/AH Model Only)  
Indoor Cover  
Air Cleaning  
Filters  
Remote Sensor  
Removes dust  
and prohibits  
germs.  
Indicators  
Indicate the  
AC setting.  
Fan Direction  
(Up/Down)  
AIR OUT  
Fan Direction  
(Left/Right)  
LCD Remote Controller  
Power Plug  
OUTDOOR UNIT  
AIR IN  
Connection Cover  
Remove cover to access the AC connection  
from this unit to the indoor unit.  
Service Valves  
AIR OUT  
The indoor and outdoor units  
are connected by copper tubes  
which are connected here.  
2
INDOOR UNIT DISPLAY  
Indoor Unit Display  
Switch Panel  
Remote Control Signal Receiver  
This place is the part to receive the signal if it receives the signal, you  
can hear the signal beep. beep.  
EMERGENCY  
REMOTE  
(DSB-F154PH)  
(DSB-F154AH)  
(DSB-F154LH)  
When the remote con-  
troller is lost or out-of-  
order, put the switch  
on the EMERGENCY to  
operate by hand.  
TIMER  
TIMER  
TIMER  
QUICK  
OXYGEN  
QUICK  
AIR CLEAN  
QUICK  
PLASMA  
ON  
ON  
ON  
ON (Red)  
Light-on  
during the  
operation  
ON (Red)  
Light-on  
during the  
operation  
ON (Red)  
Light-on  
during the  
operation.  
Timer (Yellow)  
Light-on during  
the time of  
Timer (Yellow)  
Light-on during  
the time of  
Timer (Yellow)  
Light-on during  
the time of  
Open the front panel on  
emergency operating.  
reservation mode.  
reservation mode.  
reservation mode.  
Oxygen (Green)  
Light-on  
during the  
Air clean (Green)  
Light-on  
during the  
Plasma (Green)  
Light-on  
during the  
Quick (Red)  
Light-on during  
the time of  
Quick (Red)  
Light-on during  
the time of  
Quick (Red)  
Light-on during  
the time of  
Remote mode is used with  
remote controller.  
Oxygen mode  
operation  
Plasma mode.  
Quick Mode.  
Quick Mode.  
Quick Mode.  
3
REMOTE CONTROLLER  
DSB-F154LH  
AUTO  
Display  
Displays information  
pertaining to unit.  
ON/OFF Button  
Press to turn the unit  
on or off.  
TEMPERATURE Buttons  
Press to raise or lower  
the desired temperature.  
FAN SPEED Button  
Press to select the fan speed  
(High " ", Middle " ", Low " ",  
Natural).  
FAN DIR.  
Button  
MODE  
SLEEP  
FAN SPEED  
PLASMA  
FAN DIR.  
Press to select up/down  
direction for fan.  
MODE Button  
FAN DIR.  
TIMER  
FAN DIR.  
Button  
Press to cycle through the modes  
(Auto/Quick/Cool/Fan/Dehumidifier/  
Heat)  
Press to select left/right  
direction for fan.  
ON/OFF  
ENTER/  
TURBO/MILD  
CANCEL  
TURBO/MILD  
Press to select super power  
operation (Turbo) mode.  
SLEEP Button  
Press to set the unit for  
the sleep mode.  
PLASMA Button  
Press to purify the air  
(Only DSB-F154PH)  
TIMER ON/OFF Button  
Press to set the unit off or on time.  
(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8,  
10, 12, 16, 20, 24hr)  
TIMER ENTER/CANCEL Button  
Press to enter a timer setting or  
to cancel timer setting  
COVER  
Slide down to access most  
of the remote buttons.  
Slide down further to  
access the battery  
compartment.  
REMOTE DISPLAY  
MODE Indicator (Auto/Quick/Cool/Fan/Dehumidifier/Heat)  
Light to indicate the mode selected.  
PLASMA Indicator  
Light to indicate the  
AUTO  
plasma mode. (Only DSB-F154PH)  
FAN Indicator  
Light to indicate  
the fan speed.  
FAN DIRECTION Indicator  
Light to indicate the  
fan direction.  
NATURAL Indicator  
Light to indicate the  
speeds simulating a breeze.  
TIMER Indicators (Include sleep)  
Light to indicate the timer function mode.  
TEMPERATURE & RESERVATION TIME lndicator  
Light to indicate the temperature or time.  
4
OPERATION  
CONNECTING THE AC CORD  
The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the  
indoor unit to AC, follow the procedures below:  
1. Insert the attached AC  
plug into a 2-pronged  
Only 220V or  
NOTES:  
Never connect the AC line cord plug to other than the speci-  
fied voltage (Only 220V or 220V~240V).  
Use the attached power cord only.  
AC Outlet  
and Plug  
220V~240V AC outlet.  
If the outlet is a 3-pronged type or other, have an electrician  
install a new outlet.  
The new air conditioner system should be on its own 220V  
circuit. Contact your local electrical installer for installation.  
Plug into Only 220V or 220V~240V AC Outlet.  
INFORMATION:  
1. The plug shall be connected to a ground socket outlet, and the interconnection cord shall be connected by an authorized  
electrician or specialist.  
2. Information for interconnection cable:  
Items  
Specifications  
Under 12K class  
Above 12K class  
AC 250V, 16A, H05VV-Fx1.0m2  
AC 250V, 16A, H05VV-Fx1.5m2  
3. Contact service man for the installation shall be in accordance with national wiring regulation  
HOW TO INSTALL BATTERIES  
To install the batteries, follow the procedures below:  
SLEEP  
TIMER  
1. Slide down the cover to access  
most of the remote buttons.  
Slide down further to access the  
battery compartment.  
2. Insert two AAAsize  
Alkaline batteries following  
the polarity diagram below.  
ON/OFF  
ENTER/  
CANCEL  
TURBO/MILD  
+
+
BATTERY PRECAUTIONS  
The precautions below should be followed when using batteries in this device:  
1. Use only the size and type of batteries specified.  
2. Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment.  
Reversed batteries may cause damage to the device.  
3. Do not mix different types of batteries together (e.g. Alkaline and Carbon-zinc) or old batteries with fresh ones.  
4. If the device is not to be used for a long period of time, remove the batteries to prevent damage or injury from pos-  
sible battery leakage.  
5. Do not try to recharge batteries not intended to be recharged; they can overheat and rupture. (Follow battery manu-  
facturers directions).  
5
SETTING THE UNIT FOR REMOTE OPERATION  
After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation,  
follow the procedures below:  
1. Open the indoor units cover and make sure the EMER-  
GENCY/REMOTE switch  
is set to the REMOTE  
2. Press the ON/OFF button on the remote controller to turn  
on the unit. The On LED will light on the indoor unit and  
ONwill light in the remote display.  
position; this will allow the  
unit to operate with the  
To select the various modes and  
settings, read the following pages.  
remote controller.  
EMERGENCY/REMOTE Switc  
h
THREE MINUTE COMPRESSOR DELAY  
After turning the indoor unit on and setting it for air condi-  
tioner operation, the compressor (outdoor unit) will not  
come on for three minutes. This is a feature that will protect  
the compressor from damage due to quick start and stops.  
REMOCON  
EMERGENCY  
REMOTE  
EMERGENCY  
(DSB-18/24 SERIES)  
(DSB-15 SERIES)  
CELSIUS TO FAHRENHEIT CONVERSION CHART  
CELSIUS  
FAHRENHEIT  
CELSIUS  
FAHRENHEIT  
78.8  
18  
19  
20  
21  
22  
23  
24  
25  
64.4  
66.2  
68  
26  
27  
28  
29  
30  
31  
32  
80.6  
82.4  
69.8  
71.6  
73.4  
75.2  
77  
84.2  
86  
87.8  
89.6  
NOTES: When operating the remote controller, make sure there are no obstructions between the remote  
controller and the remote sensor.  
After a while the display goes blank to conserve battery power. To check the settings, press the  
ON/OFF button once.  
TO SET THE UNIT TO AUTO MODE  
This unit will automatically operate the unit according to its surroundings while in the Auto mode. All you have to set is  
the desired temperature and it will control the fan, coolness and dehumidifier. Follow procedures below:  
1.Press the ON/OFF button on the remote control to  
AUTO  
2. Make sure the  
indicator appears in the remote dis-  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in the  
remote display.  
play. Using the TEMP. or buttons, set the desired  
temperature. The desired temperature can be changed up  
or down 1 degree from the actual room temperature. For  
temperature setting: 24~28°C  
AUTO  
3. Then the unit will automatically  
operate.  
6
SET UNIT TO QUICK MODE  
To set this unit to cool or heat (Heat pump model only) at the highest power, follow the procedures below:  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in the remote display.  
2.Press the MODE button until the Quick (“  
cator blinks.  
) indi-  
3. The unit will then start cooling or heating the room at  
the highest power.  
TO SET UNIT TO COOL MODE  
To set the unit to cool the room to a desired temperature, follow the procedures below:  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in the remote display.  
2.Press the MODE button until the Cool indicator  
appears in the display.  
3. Using the TEMP. or buttons, set the desired tem-  
perature. The desired temperature can be changed up  
to 32°C and down to 18°C.  
4. To select the fan speed, press the FAN SPEED button  
until the desired speed appears in the display (see  
below).  
FAN SPEEDS  
AUTO  
AUTO”  
The fan will automatically select the fan speed.  
The fan will operate on low speed.  
The fan will operate on medium speed.  
The fan will operate on high speed.  
NATURALThe fan will randomly cycle through the  
speeds simulating a cool breeze.  
7
TO OPERATE ONLY FAN  
To operate only the fan so the unit will circulate the air, proceed as follows:  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in the remote display.  
2.Press the MODE button until the Fan indicator  
appears  
in the display. No allowance setting  
temperature  
3. To select a fan speed, press the FAN SPEED button  
until the desired speed appears in the display (see  
below).  
FAN SPEEDS  
The fan will operate on low speed.  
The fan will operate on medium speed.  
The fan will operate on high speed.  
NOTE:  
If NATURALis selected, the NATURALindicator on  
the indoor unit will light.  
NATURALThe fan will randomly cycle through the  
speeds simulating a breeze.  
TO SET UNIT TO DEHUMIDIFIER MODE  
Select this mode when there is high humidity. To select, follow the procedures below.  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in the remote display.  
2.Press the MODE button until the Dehumidifier indica-  
tor appears in the display.  
Using the TEMP.  
perature. The desired temperature can be changed up  
buttons, set the desired tem-  
or ꢀ  
3.  
to 32°C and down to 18°C.  
8
TO SET UNIT TO HEAT MODE (ONLY HEAT PUMP MODEL)  
To set the unit to heat the room to a desired temperature, follow the procedures below:  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will light on the indoor  
unit and ONwill light in  
2.Press the MODE button until the Heat  
indicator appears in the display.  
In the heat mode, the fan direction (UP,  
DOWN) is further downward than that in  
the cool mode for the good circulation.  
the remote display.  
3. Using the TEMP. or buttons, set the desired tem-  
perature. The desired temperature can be changed up  
to 32°C and down to 18°C.  
4. To select the fan speed, press the FAN  
SPEED button until the desired speed  
appears in the display (see below).  
NOTE:  
When the heating orperation is started, hot air deliv-  
ery might be delayed due to warm up period.  
FAN SPEEDS  
AUTO”  
The fan will automatically select the fan  
speed.  
The fan will operate on low speed.  
The fan will operate on medium speed.  
The fan will operate on high speed.  
NATURALThe fan will randomly cycle through the  
speeds simulating a cool breeze.  
TO SELECT THE FAN DIRECTION  
Regardless of the mode the unit is set for, the fan direction can be changed so it moves up and down, left and right or  
both. Follow procedures below to set fan direction.  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will  
2.Press the MODE button to select the desired mode.  
light on the indoor unit and ON”  
will light in the remote display.  
3. Press the FAN DIR. button to select the fan direction.  
See chart below for detailed information on each of  
the two settings.  
FAN DIR.  
FAN DIR.  
First Press  
The air will flow up  
and down.  
FAN DIR.  
First Press  
The air will flow left  
and right.  
Second  
Press  
Second  
Press  
Normal air direction.  
Normal air direction.  
(DSB-15 SERIES)  
9
TO SET THE ON TIMER MODE  
This unit can be set to automatically turn on after a predetermined amount of hours (up to 24) in the order of 0.5, 1, 1.5,  
2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 16, 20, 24.  
1. Press the ON/OFF button of timer on the remote control to set the on timer mode, HOURand ONon the remote  
display will be displayed and TIMERwill be flicked. When you increase to press ON/OFFyou will get desired  
time. Then, if pressing ENTER/CANCELbutton, ON TIMER Mode will be started. If you want to stop ON TIMER  
Mode, please press ENTER/CANCELagain.  
2. While the unit is off, press the TIMER ON button; the  
display will light waiting input for the timer, but the  
actual unit will not turn on.  
Press the ENTER button to input the setting into  
memory; the unit will beep, the TIMER indicator will  
light on the unit and the TIMER indicator on the  
remote will light to indicate the unit is in the timer  
mode.  
3.Repeatedly press the TIMER ON button until the  
desired hour that you want the unit to turn on appears  
on the display.  
For example, if it is 1:00 P.M. and you want the unit  
to turn on at 4:00 P.M., select 3 hours.  
4.  
5. When the desired hour is reached, the unit will turn on  
to the selected mode.  
AUTO  
NOTE:  
Press the ENTER button within 5 seconds of  
selecting the desired time. If mote than 5 seconds  
elapse, steps 3 and 4 must be repeated.  
10  
TO SET THE OFF TIMER MODE  
This unit can be set to automatically turn off after a predetermined amount of hours (up to 12) in the order of 0.5, 1, 1.5,  
2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 7.5, 8, 8.5, 9, 9.5, 10, 11, 12.  
1. Press the ON/OFF button of timer on the remote control to set the off timer mode, HOURand OFFon the remote  
display will be displayed and TIMERwill be flicked. When you increase to press ON/OFFyou will get desired time.  
Then, if pressing ENTER/CANCELbutton, OFF TIMER Mode will be started. If you want to stop OFF TIMER Mode,  
please press ENTER/CANCELagain.  
2. Press the TIMER OFF button once to enter the Timer  
screen.  
AUTO  
Press the ENTER button to input the setting into  
memory; the unit will beep, the TIMER indicator will  
light on the unit and the TIMER indicator on the  
remote will light to indicate the unit is in the timer  
mode.  
3.Repeatedly press the TIMER OFF button until the  
desired hour that you want the unit to shut off  
appears on the display.  
For example, if it is 8:00 P.M. and you want the unit  
to turn off at 10:00 P.M., select 2 hours.  
4.  
5.When the desired hour is reached, the unit will turn  
off.  
AUTO  
NOTE:  
Press the ENTER button within 5 seconds of  
selecting the desired time. If mote than 5 seconds  
elapse, steps 3 and 4 must be repeated.  
11  
TO SET UNIT TO SLEEP MODE  
When you are going to sleep, select this feature and the unit will cool off the room to the desired temperature and then  
increase that temperature throughout the night.  
1.Press the ON/OFF button on the remote control to  
turn the unit on; the On LED will  
light on the indoor unit and ON”  
2.Press the MODE button to select the  
desired mode. Then, set the desired  
temperature using the TEMP. or ꢀ  
buttons.  
will light in the remote display.  
Press the SLEEP button on the remote controller.  
The unit will then be in the sleep mode  
and will cool the room to the desired  
temperature. After a while the unit will  
increase the temperature again.  
3.  
TO CANCEL SLEEP MODE:  
To cancel sleep mode, press  
AUTO  
the SLEEP button again; the  
SLEEP indicator will disappear  
in the display.  
This process will then repeat.  
TO SET TURBO/MILD MODE  
1. The unit is tixed MILDmode on production.  
2. Press the TURBO/MILDbutton for powerful operation.  
After 30 minutes, function returns automatically to MILDmode.  
3. TURBObutton does not operate in a HEATmode  
4. When press the TURBO/MILDbutton one more time, it will be back to MILDmode.  
EMERGENCY OPERATION  
If the remote control is lost, broken or has no batteries, follow the procedures below:  
1.Open the indoor units cover and make sure the  
EMERGENCY/REMOTE switch is set to the EMER-  
GENCY position.  
2.The unit will then turn on and depending on the room  
temperature, it will select the cool or dehumidifier  
mode, fan speed and fan direction automatically.  
EMERGENCY/REMOTE Switch  
To turn the unit off, slide the  
EMERGENCY/ REMOTE  
switch to the REMOTE position.  
3.  
EMERGENCY/REMOTE Switch  
12  
CHANGING/CLEANING THE AIR FILTERS  
To change or clean the two black air filters, follow the procedures below:  
1.Open the indoor units cover and remove both black  
air filters by bending them slightly backward and the  
lifting out.  
2. Remove the two small filters (Deodorizing and  
Electrostatic) from the indoor unit.  
After removing the connection terminal of electric dust  
collector, remove the electric dust collector.  
3. Examine the filters and determine if they need to be  
cleaned or replaced. To clean filters, use a vacuum and  
clean off dust. Use water and mild soap also if necessary.  
4.Insert cleaned or new small filters (Deodorizing and  
Electrostatic) back into the unit.  
After putting the connection terminal into electric dust  
collector, insert the electric dust colloctor into the unit.  
NOTE: The filters should be changed every 6 months. If in  
a climate with cold winters, once a year is adequate.  
5. Insert cleaned or new black filters back into the unit.  
Caution  
When you remove the electric dust collector, you must remove the power plug.  
13  
CHANGING/CLEANING THE AIR FILTERS  
To change or clean the two black air filters, follow the procedures below:  
1. Open the indoor units cover and remove both black  
air filters by bending them slightly backward and the  
lifting out.  
2. Remove the two small filters (Deodorizing and  
Electrostatic) from the indoor unit.  
After removing the connection terminal of electric dust  
collector, remove the electric dust collector.  
(LH/PH/AH Model Only)  
3. Examine the filters and determine if they need to be  
cleaned or replaced. To clean filters, use a vacuum  
and clean off dust. Use water and mild soap also if  
necessary.  
4. Insert cleaned or new small filters (Deodorizing and  
Electrostatic) back into the unit.  
After putting the connection terminal into electric dust  
collector, insert the electric dust colloctor into the unit.  
(Only DSB-F154LH/154PH/154AH)  
NOTE: The filters should be changed every 6 months.  
If in a climate with cold winters, once a year is  
adequate.  
5. Insert cleaned or new black filters back into the unit.  
CautionWhen you remove the electric dust collector, you must remove the power plug.  
INSTALLING THE REMOTE BRACKET  
To install the remote bracket, insert one of the 2 supplied screws into top  
hole of the bracket and into the wall. Level the remote bracket and insert the  
other screw into the bottom hole.  
Insert the remote controller when not using it.  
14  
CARE AND MAINTENANCE  
warning  
Make sure the AC cord is unplugged and the unit is off before cleaning.  
Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged.  
Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth.  
NEVER USE Solvents, harsh chemicals or hot water to clean the unit.  
Some metal edges on the unit are sharp. Be careful when cleaning or handling.  
Internal parts in the outdoor unit may need cleaning or routine maintenance from time to time. Consult your local ser-  
vice center for more details.  
AFTER THE SEASON:  
Operate the fan, then dry the indoor unit.  
Shut off the indoor unit and then unplug it from the wall.  
Clean the air filters.  
Cover the outdoor unit with the supplied cover; this is very important to protect this unit.  
BEFORE THE SEASON:  
Make sure the air filters are clean.  
Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions.  
Make sure the unit is grounded. Consult a serviceman for help.  
PRECAUTIONS:  
Do not use this unit for animal or plant storage.  
In a lightning or thunder storm, immediately unplug it from the wall.  
15  
TROUBLESHOOTING GUIDE  
Before requesting service, please refer to the chart below for possible solutions:  
SYSPTOMS  
POSSIBLE CAUSE  
POSSIBLE SOLUTIONS  
No power.  
Power failure.  
Restore the power  
Line voltage too low.  
Contact electrician to install new outlet.  
Insert plug all the way.  
Unit is unplugged or not completely  
plugged in.  
Unit is off.  
Turn unit on.  
Batteries in remote are weak or dead.  
Replace remotes batteries.  
EMERGENCY/REMOTE  
switch is not set to REMOTE.  
Slide EMERGENCY/REMOTE  
to REMOTE.  
The compressor does  
not turn on.  
(no cool air at cooling)  
(no heat air at heating)  
When the unit is first plugged in  
and turned on, the compressor  
will delay turn on for 3 minutes.  
Wait 3 minutes for the unit to operate.  
If the unit is turned off and then  
immediately back on, the compressor  
will delay for 3 minutes.  
Wait 3 minutes for the unit to operate.  
The air filter(s) is dirty or clogged.  
A door or window is open.  
Clean or replace filter(s).  
Shut door or window.  
Remove obstacle.  
There is an obstacle in front of  
intake or indoor unit.  
The temperature has been set  
improperly.  
Check and reset if necessary.  
This is normal.  
Strange sounds occur.  
During operation, especially after  
turning it on or off, refrigerant flows  
inside the unit.  
Strange smells occur.  
No remote operation.  
The fan is bringing out the  
smells of the carpet, walls, etc.  
The smell should go away shortly.  
Replace batteries.  
Batteries are weak, dead or  
inserted improperly.  
Remote is out of range.  
Move closer to unit.  
Aim remote at sensor.  
Remove obstruction.  
Remote not aimed at sensor.  
There is an obstruction between  
unit and remote.  
16  
INSTRUCTION OF INSTALLATION  
Below is an overview for the connection of the Indoor unit to the Outdoor unit.  
OVERVIEW  
This appliance must be installed according to national power supply acquirement.  
10cm (3.95in)  
from ceiling  
30cm (11.8in) from  
side wall  
10cm (3.95in) from  
Wall  
side wall  
Wall  
Bracket  
Drain  
Hose  
Wall Cap  
Oxygen tube  
At least 30cm  
(11.8in) from unit  
Pipes  
(Not Supplied)  
AC  
Connection  
(Not Supplied)  
AC Outlet  
and Plug  
Wrap with  
Tape  
Plug into 220V~240V  
AC Outlet  
Maximum Height 7M (21Ft)  
Maximum Length 15M (49Ft)  
Any tube length between 7 and 15 meters must  
be precharged with freon using the following calulation:  
(Length 5) x 30 grams  
23.6  
inches  
Adding additonal tubing will decrease efficiency  
3.9 inches  
27.6  
inches  
NOTES:  
After installation it must be  
possible for the user to dis -  
connect the power supply  
plug.  
Copper  
Drain  
Tubing  
Hose  
If the AC outlet is a 3-  
pronged type or other, have  
an electrician install a new  
outlet.  
Ground Wire  
(Not Supplied)  
23.6  
inches  
Contanct service man when  
replace the power cord set.  
The specification of AC con-  
nection is 2.0mm2 x 3C x 6m.  
Gas side piping  
Oxygen tube  
Gas side piping  
Oxygen tube  
Connecting  
cable  
Connecting  
cable  
Liquid side piping  
Liquid side piping  
Drain Hose  
Drain Hose  
Cooling Only  
Heating & Cooling  
* DSB-AH Series model has oxygen tube, but the other models do not.  
17  

Aiphone LAF C CONSOLE MASTER LAF 40C User Manual
Black Decker VP110 User Manual
Brother Printer DCP J140W User Manual
Bryant 599C User Manual
Canon RUNNER C5051 User Manual
Epson Printer R2400 User Manual
Epson Stylus CX7400 User Manual
Friedrich Air Conditioner SV10A10 User Manual
Haier AS072ADAAA User Manual
Honda Automobiles Backup Sensors 4622040M User Manual