Cino FUZZYSCAN F600 User Manual

BARCODE IMAGER  
Programming Manual  
International Edition, Rev. C5  
Revision History  
Rev. No.  
Released Date  
Description  
Rev.B Beta  
Apr. 16, 2009  
First Release  
Page 22  
Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4”  
and ISBT Concatenation On option code to “5”.  
Rev.B  
May 05, 2009  
June 22, 2009  
Page 25  
Page 46  
GS1 Databar Setting – All GS1 databar default values are changed to Enable.  
Add “Symbology ID Table”.  
Page 34  
Page 37  
Add “Presentation Scanning Mode”.  
Add “Time Delay to Low Power Mode”.  
Rev.B1  
Page 9, 11 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code”.  
Page 26  
Add “Composite Code Setting”, “PDF/Micro PDF417 Setting”,  
“Codablock F Setting”, Korea Post Code Setting”.  
Add “SmartStand Power Off Timeout”.  
Page 39  
Page 46  
Rev.B2  
Rev.B3  
Aug. 21, 2009  
Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code” into  
Condensed DataWizard Table.  
Page 48  
Add “PDF417/Micro PDF417”, “Codablock F”, “Composite Code”,  
“Korea Post Code” IDs into Symbology ID Table.  
Page 8  
Add “IBM PS/2, 25-30 series keyboard wedge interface”.  
Oct. 16, 2009  
Page 39 Add “Presentation Scanning Auto-sense”.  
Page 48 Add “Code 128” ID into Symbology ID Table.  
Page 15 Modify UPC-E/EAN-8 expansion and UPC-A standardization  
Page 33 Rename “Time Out Control” to “Serial Response Time-out”.  
Page 35 Rename “Presentation Scanning Mode” to “Presentation Control”.  
Page 38 Rename “Auto Power Off Duration” to “Light Source On Time”.  
Add “Extremely short” option to Good Read Duration.  
Rev.B4  
Rev. B5  
Mar. 05, 2010  
Apr.12, 2010  
Page 39 Rename “Presentation Scanning Auto-sense” to “Presentation Auto-sense”.  
Add “Presentation Sensitivity”  
Page 54 System Commands – Add “Master Default” quick set command.  
Page 38 Hands Free Time-out – Add “Disable”.  
Page 39 Add “Trigger Control” (only available for FuzzyScan F460/F468).  
Revision History  
Rev. No.  
Released Date  
Description  
Rev. B6  
May 27, 2010 Page 33  
Baud Rate – Add 57.6K BPS and 115.2K BPS.  
Page 17  
Add “UPC/EAN Security Level”.  
Rev. B7  
Rev. B8  
Jun 25 , 2010 Page 38  
Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode"  
and change the default value from 5 seconds to immediate.  
Page 15,16  
Page 17  
Add “ Supplement Scan Voting”.  
Add “EAN Supplement Control”.  
Page 28  
Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename  
Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to  
Spain (Latin America, QWERTY).  
Sep 29 , 2010  
Page 37  
Page 38  
Add “Good Read Indicator”.  
“Scan Rate Control”.  
Rev. B9  
Rev. C1  
Nov 10 , 2010 Page 34  
Mar 04, 2011 Page 34  
Baud Rate – Cancel Baud Rate 300/600 BPS.  
Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9.  
Page 13  
Add ”Code 39 Security Level”.  
Add “NAK Retry Count”.  
Rev. C2  
Rev. C3  
Mar 22, 2011 Page 35  
Add “ACK/NAK Transmission Indication”.  
Page 9, 19, 24, 51 UCC/EAN-128 was renamed GS1-128  
Page 35  
Page 36  
Page 44  
Add new parameters to “ACK Indication”  
Modify “Serial Response Time-out” parameters.  
Add “Laser Aiming Control” function.  
Jul 22, 2011  
Rev. C4  
Rev. C5  
Nov 04, 2011 Page 14  
Add “Codabar Check Digit Settings”  
Page 38  
Jan 02, 2012  
Wand/Laser Emulation Control – Cancel “Output Polarity”, “Initial Signal  
State”, “Margin Time”, “Module Time” ,and “Narrow/Wide Ratio”  
Page 38  
Code 39/Code 128 Emulation – Change the default setting to option code 1.  
© Copyright Cino Group  
© Copyright PC Worth Int’l Co., Ltd  
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of  
merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental  
consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains  
proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,  
reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written  
permission of Cino. All product information and specifications shown in this document may be changed without prior notice.  
Warranty  
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the  
product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different  
warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident  
or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized  
representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied  
software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but  
not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA  
procedures to return Cino for inspection.  
Regulatory  
FCC part 15B  
EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2  
CNS13438  
AS/NZS CISPR 22:2009 Class B  
KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)  
LED Eye Safety  
Laser Eye Safety  
IEC62471 Exempt group  
IEC60825-1 Class 1  
Table of Contents  
Getting Started  
Getting Familiar with Your FuzzyScan  
Connecting to Your Host  
Using Accessories  
1
1
2
Configure Your FuzzyScan  
Bar Code Programming Manual  
Programming Procedures  
Host Interface Selection  
Symbology Reading Control  
Keyboard Interface Control  
Serial Interface Control  
3
4
8
9
23  
32  
35  
36  
41  
Wand/Laser Emulation Control  
Operation Control  
Condensed DataWizard  
Appendix  
Symbology ID Table  
48  
49  
50  
51  
52  
53  
54  
Keyboard Function Code Table  
ASCII Input Shortcut  
Host Interface Quick Set  
Operation Mode Quick Set  
Option Codes  
System Commands  
Getting Started  
Getting Familiar with Your FuzzyScan  
Connecting to Your Host  
Thank you for choosing Cino FuzzyScan Imager. All  
FuzzyScan imagers deliver world-class performance for a  
broad range of applications to unleash your productivity. This  
document provides an easy reference for installation and  
operation purposes. A complete documentation is provided  
by the FuzzyScan Programming Manual available at  
FuzzyScan imagers support PS/2(DOS/V) Keyboard  
Wedge, RS-232 Serial, and USB interfaces. Please  
choose your desired interface cable, then plug it into the  
cable interface port of the imager and connect it to the  
host. If you would like to remove the cable, please  
straighten one end of a paper clip, then insert it into the  
cable release hole to pull out the cable.  
F700 & L700 Series  
USB  
F600 & L600 Series  
Power Indicator  
Status Indicator  
Trigger  
RS232 Serial  
Scan Window  
Beeper  
Cable Release Hole  
F400 Series  
PS/2(DOS/V) Keyboard Wedge  
1
Getting Started  
Using Accessories  
You can enhance productivity of your workforce by using  
various accessories to fulfill a wide variety of application  
demand.  
Universal Holder  
A stylish Universal Holder is designed for  
storing your imager when not in use. It  
serves to protect the imager from  
lens-scratched or falling. Moreover, its  
artistic-design enhances the entire value  
of the imager.  
Hand-free SmartStand  
A SmartStand is specifically designed  
for hand-free applications to maximize  
user’s comfort and productivity. You  
can adjust the scanner holder to  
desired  
position  
for  
optimized  
scanning.  
Thanks to the auto-sense design, the  
imager is capable of switching  
between presentation scanning and  
hand-held scanning automatically  
while working with SmartStand.  
Please note that the SmartStand is  
not applicable for F400 Series imager.  
2
Configure Your FuzzyScan  
Bar Code Programming Menu  
The FuzzyScan bar code commands are specially designed  
Proprietary bar code labels which allow you to set the  
FuzzyScan internal programming parameters. There are  
System Command, Family Code and Option Code for  
programming purpose.  
System Command  
The System Command is the highest level bar code  
command which directs FuzzyScan to perform immediate  
operations, such as entering programming mode  
(PROGRAM), exiting programming mode (EXIT), listing  
system information (SYSLIST), recovering to factory  
preset configurations (M_DEFAULT) and so on. Please  
note that all system commands will take a few seconds to  
complete the operations. User must wait for the  
completion beeps before scanning another bar code.  
Each programmable family and bar code command label is  
listed on the same page with major system commands. The  
detailed explanations and special programming flowchart are  
printed on facing or following pages. You can read the  
explanation and set the FuzzyScan concurrently.  
A supplemental bar code command menu incorporates the  
bar code command labels of System Command and Option  
Code. As you set the FuzzyScan, open the bar code  
command menu to find the option code page. You may scan  
the desired family code and option code to set FuzzyScan. If  
you want to change the programming family for multiple  
settings, you need only turn over the programming page to  
find next desired programming family.  
Family Code  
The Family Code is scanned to select the user desired  
programming family. FuzzyScan has already provided  
more than one hundred programming families to meet any  
specific requirements.  
Option Code  
The Option Codes is a set of bar code commands  
represented by “0–9”, “A–F” and finishing selection (FIN).  
For most setting, you must select at least one option code  
following the family code selection to set the desired  
parameter for the selected programming family.  
3
Configure Your FuzzyScan  
Programming Procedures  
As you scan the bar code command to select the desired  
parameters, information about the final selected parameters  
represented by the bar code commands are stored in the  
FuzzyScan’s internal Flash Memory ASIC or non-volatile  
memory. If you turn off the unit, the Flash Memory ASIC or  
non-volatile memory retains all programming options. You  
need not re-program the FuzzyScan if you want to keep the  
existing configurations in the next power on.  
If the programming family must take multiple scans  
selection, cycling scan selection, or dual level selection  
procedures, the family of the programming menu will be  
marked with the matched representing symbol of  
Programming Category (P.C.) in bold font listed in the  
following table. You can easily find the bold mark in the  
programming menu, and refer to their flowcharts for details.  
Before setting the FuzzyScan, please also refer to the  
“Beeping Indications” listed in Appendix to understand the  
details of programming beeping indications. It will be very  
helpful for you to know the existing status while you are  
programming the FuzzyScan.  
The programming procedures of FuzzyScan are designed  
as simple as possible for ease of setting. Most  
programming families take the Single Scan Selection  
programming procedure. But several programming families  
have more complex and flexible programmable options,  
and you must take Multiple Scans Selection, Cycling  
Scan Selection or Dual Level Selection to complete their  
programming procedures. Each kind of programming  
procedure is listed in the following pages for your reference.  
Please give careful attention to become familiar with each  
programming procedure.  
Conventions of Programming Menu  
Conventions  
Descriptions  
Factory Default Value  
Programming Category  
P.C.  
SS : Single scan selection  
MS : Multiple scans selection  
CS : Cycling scan selection  
DS : Dual level scan selection  
(
[
)
]
Necessary Option Code  
Selectable Option Code  
4
Configure Your FuzzyScan  
Program & End  
System List, Group & Master Default  
Scan  
Scan  
PROGRAM”  
SYSLIST  
FuzzyScan will list the product information and  
revision number to host via selected host interface,  
then issue the completion beeping.  
FuzzyScan will enter programming mode,  
and inhibit all non-programming functions.  
Scan  
Scan  
M_DEFAULT”  
END”  
FuzzyScan will exit programming mode, and store all  
parameters in Flash Memory ASIC or non-volatile memory,  
then issue the completion beeping.  
FuzzyScan will recover all programmable  
parameters into factory preset configurations,  
then issue the completion beeping.  
Please note that the FuzzyScan will take 3-4 seconds to  
store parameters in internal Flash Memory ASIC or  
non-volatile memory after you scan the “END”. Please  
don’t turn off the power before the completion beeping. It  
may destroy all configured parameters.  
5
Configure Your FuzzyScan  
Single scan selection  
Multiple scans selection  
Scan  
Scan  
Enter programming mode.  
PROGRAM”  
Enter programming mode.  
PROGRAM  
Select one of desired  
programming families.  
Select one of desired  
programming families.  
Scan  
Scan  
One of Family Codes  
One of  
Codes  
Family  
1. Select one or several  
option codes to select  
desired parameters.  
Select one option code of  
desired parameter.  
Scan One or  
Scan  
Several  
Codes  
Option  
One of Option Codes  
2. If it’s necessary, scan  
“FIN” to terminate  
Yes  
Want to select another  
programming family?  
option code selection.  
Yes  
Repeat  
Repeat  
Selection  
Selection  
Want to select another  
programming family?  
No  
No  
Scan  
Scan  
Exit programming mode.  
Exit programming mode.  
END”  
END  
6
Configure Your FuzzyScan  
Cycling scan selection  
Dual level selection  
Scan  
Scan  
Enter programming mode.  
“PROGRAM”  
Enter programming mode.  
PROGRAM”  
Select one of desired  
programming families.  
Select one of desired  
programming families.  
Scan  
Scan  
One of Family Codes  
One of Family Codes  
Cycling select one or  
several option codes of  
desired parameters as  
“Single” or “Multiple”  
scans selection.  
Select several option codes  
of desired parameters.  
(1st) Scan  
Scan  
Several Option Codes  
One of Option Codes  
1. Select one or several  
option codes of desired  
parameters.  
(2nd) Scan One or  
Scan “FIN”  
Several  
Codes  
Option  
2. If it’s necessary, scan  
“FIN” to terminate  
Finish cycling selection.  
(If necessary)  
option code selection.  
Yes  
Yes  
Repeat  
Repeat  
Selection  
Selection  
Want to select another  
programming family?  
Want to select another  
programming family?  
No  
No  
Scan  
Scan  
Exit programming mode.  
Exit programming mode.  
END  
END  
7
Configure Your FuzzyScan  
Host Interface Selection  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Host Interface Selection  
P.C  
Parameter Selection  
Option Code  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
MS  
IBM PS/2, 25-30 series keyboard wedge interface  
Standard/TTL RS-232 peer-to-peer serial  
Wand emulation  
02  
06  
08  
09  
10  
13  
14  
17  
18  
19  
USB Com Port Emulation  
PS/2 (DOS/V) direct link (keyboard replacement)  
PS/2 (DOS/V) keyboard wedge turbo mode  
PS/2 (DOS/V) keyboard wedge standard mode  
Laser emulation  
USB HID standard mode  
USB HID turbo mode  
8
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
User Defined Symbol ID ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Symbol ID : 1 character  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
DS  
Code 128 (default=B)  
GS1-128 (default=C)  
UPC-A (default=A)  
EAN-13 (default=F)  
Codabar/NW-7 (default=D)  
Code 39/Code 32 (default=G)  
Code 93 (default=H)  
Standard/Industrial 2 of 5 (default=I)  
Interleaved 2 of 5 (default=J)  
Matrix 2 of 5 (default=K)  
China Postal Code (default=L)  
German Postal Code (default=M)  
IATA (default=O)  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
26  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
(1 character)  
Code 11 (default=P)  
MSI/Plessey (default=R)  
UK/Plessey (default=S)  
Telepen (default=T)  
GS1 DataBar (default=X)  
UPC-E (default=E)  
EAN-8 (default=N)  
Trioptic Code 39 (Default=W)  
UCC Coupon Extended Code (Default=Z)  
PDF417/Micro PDF417 (default=V)  
Codablock F (default=Y)  
Korea Post Code (default =a)  
9
                                                                                                                                  
                                                                                                                                                                                             
Configure Your FuzzyScan  
Symbology Reading Control  
Symbology ID Transmission ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Symbology ID Transmission  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable symbology ID transmission  
0
1
2
3
4
5
6
Enable prefix CINO symbology ID transmission  
Enable suffix CINO symbology ID transmission  
Enable both prefix and suffix CINO symbology ID transmission  
Enable prefix AIM symbology ID transmission  
Enable suffix AIM symbology ID transmission  
Enable both prefix and suffix AIM symbology ID transmission  
10  
                                                                                                                                    
                                                                                                                                                                                            
Configure Your FuzzyScan  
Symbology Reading Control  
Readable Bar Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Readable Symbology Setting  
P.C  
Parameter Selection  
Option Code  
SS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
CS  
Auto  
00  
01  
02  
03  
04  
05  
06  
07  
47  
08  
38  
48  
58  
68  
09  
10  
11  
12  
13  
14  
15  
17  
18  
21  
Code 128 *  
UPC-A *  
UPC-E *  
EAN-13 *  
EAN-8 *  
Codabar/NW-7 *  
Code 39 *  
Trioptic Code 39  
Standard/Industrial 2 of 5  
Matrix 2 of 5  
Interleaved 2 of 5 *  
China Postal Code  
German Postal Code  
Code 93 *  
Code 11  
MSI/Plessey  
UK/Plessey  
Telepen  
GS1 DataBar (RSS-14) *  
IATA  
PDF417/Micro PDF417  
Codablock F  
Korea Post Code  
Remember to scan “FIN” to terminate  
this selection. But if you select the  
“ Auto ”, FuzzyScan will terminate this  
selection automatically.  
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add  
the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.  
Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.  
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.  
11  
                                                                                                                                                  
                                                                                                                                                                                                          
Configure Your FuzzyScan  
Symbology Reading Control  
Code 39/Code 32 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 39 Family Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 39  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
Enable Code 39  
Select Standard Code 39 as primary format  
Select Full ASCII Code 39 as primary format  
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format  
Disable start/stop symbol transmission  
Enable start/stop symbol transmission  
Disable Code 32 leading A transmission  
Enable Code 32 leading A transmission  
Disable MOD 43 check digit verification  
Enable MOD 43 check digit verification  
Disable check digit transmission  
Enable check digit transmission  
Disable Code 39 buffering  
Enable Code 39 buffering  
SS  
SS  
Disable Trioptic Code 39  
Enable Trioptic Code 39  
0
1
Trioptic Code 39 Setting  
Code 39 Min. Length  
Code 39 Max. Length  
SS  
MS  
Default (01)  
FIN  
(2 digits)  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.  
12  
                                                                                                                                                           
                                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
Code 39 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 39 Security Level  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
Level 0  
Level 1  
Level 2  
Level 3  
0
1
2
3
Code 39 Security Level  
The scanner offers four levels of decode security for Code39 bar codes:  
Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.  
Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.  
Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.  
Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.  
13  
                                                                                                                                        
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Codabar/NW-7 Setting ♦  
PROGRAM  
Family Code Selection  
Codabar Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Codabar  
Enable Codabar  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
Select Codabar standard format  
Select Codabar ABC format  
Select Codabar CLSI format  
Select Codabar CX format  
Disable start/stop symbol transmission  
Enable ABCD/ABCD start/stop symbol transmission  
Enable abcd/abcd start/stop symbol transmission  
Enable ABCD/TN*E start/stop symbol transmission  
Enable abcd/tn*e start/stop symbol transmission  
Disable check digit verification  
Enable check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Modulus 16  
0
1
2
3
4
5
6
Codabar Check Digit Settings  
Modulus 10/weight 3  
Modulus 11  
Modulus 10/weight 2  
7 check DR  
Weight Modulus 11  
Runes (Modulus 10/weight 2)  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Codabar Min. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
14  
                                                                                                                                        
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Codabar/NW-7 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Codabar Max. Length  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
15  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
UPC-A & UPC-E Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC Family Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable UPC-A  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Enable UPC-A  
Disable UPC-E  
Enable UPC-E  
Disable UPC-E expansion  
Enable UPC-E expansion  
Disable UPC standardization  
Enable UPC standardization  
Disable UPC numeric system  
Enable UPC numeric system  
Disable UPC-A check digit transmission  
Enable UPC-A check digit transmission  
Disable UPC-E check digit transmission  
Enable UPC-E check digit transmission  
Disable UPC “leading 1” portion  
Enable UPC “leading 1” portion  
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric  
system, UPC-A check digit transmission.  
UPC-E & EAN-8 Expansion  
UPC-A Standardization  
UPC Lead 1 Numeric System  
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.  
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.  
: Enable to read UPC leading with the 1 numeric system, you must enable this option.  
WPC Selection  
(UPC/EAN/CAN)  
Disable  
Check Digit  
Disable  
Numeric System  
With 2-digit  
Addendum  
With 5-digit  
Addendum  
Enable  
Standardization  
Enable  
Expansion  
Basic Length  
UPC-A  
UPC-E  
EAN-13  
EAN-8  
12  
8
13  
8
- 1  
- 1  
- 1  
- 1  
- 1  
- 1  
NC  
NC  
+ 2  
+ 2  
+ 2  
+ 2  
+ 5  
+ 5  
+ 5  
+ 5  
+ 1  
+ 1  
NC  
NC  
0
+ 4  
0
+ 5  
16  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Symbology Reading Control  
UPC-A & UPC-E Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC Supplement Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Select UPC without supplement digits  
0
1
2
3
4
5
6
7
Select UPC with only 2 supplement digits  
Select UPC with only 5 supplement digits  
Select UPC with 2/5 supplement digits  
Disable force supplement digits output  
Enable force supplement digits output  
UPC Family Addenda Separator Off  
UPC Family Addenda Separator On  
SS  
SS  
Level 0  
Level 1  
Level 2  
0
1
UPC/EAN Security Level  
Supplement Scan Voting  
SS  
2
Only available for UPC-A & EAN-13  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
Level 8  
Level 9  
Level 10  
Level 11  
Level 12  
Level 13  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
UPC/EAN Security Level  
The scanner offers three levels of decode security for UPC/EAN bar codes:  
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this  
security level may significantly impair the decoding ability of the scanner.  
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.  
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may  
increase the misread.  
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding  
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5  
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,  
low contrast or damage barcode labels.  
17  
                                                                                                                         
                                                                                                                                                                                                       
Configure Your FuzzyScan  
Symbology Reading Control  
EAN Setting, EAN Supplement Setting ♦  
PROGRAM  
Family Code Selection  
EAN Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable EAN-13  
Enable EAN-13  
Disable EAN-8  
0
1
2
3
4
5
6
7
8
9
A
B
Enable EAN-8  
Disable EAN-8 expansion  
Enable EAN-8 expansion  
Disable EAN-13 check digit transmission  
Enable EAN-13 check digit transmission  
Disable EAN-8 check digit transmission  
Enable EAN-8 check digit transmission  
Disable ISBN/ISSN Conversion reading check  
Enable ISBN/ISSN Conversion reading check  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Select EAN without supplement digits  
0
1
2
3
4
5
6
7
EAN Supplement Setting  
Select EAN with only 2 supplement digits  
Select EAN with only 5 supplement digits  
Select EAN with 2/5 supplement digits  
Disable force supplement digits output  
Enable force supplement digits output  
EAN Addenda Separator Off  
EAN Addenda Separator On  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
Level 8  
Level 9  
Level 10  
Level 11  
Level 12  
Level 13  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
Supplement Scan Voting  
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding  
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5  
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,  
low contrast or damage barcode labels.  
18  
                                                                                                                                    
                                                                                                                                                                                            
Configure Your FuzzyScan  
Symbology Reading Control  
EAN Security Level Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UPC/EAN Security Level  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Level 0  
Level 1  
Level 2  
0
1
SS  
2
Only available for UPC-A & EAN-13  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable all specific prefix supplement digital output  
Enable all specific prefix supplement digital output  
Enable 491 Supplement Digit Output  
Enable 978/979 Supplement Digit Output  
Enable 977 Supplement Digit Output  
Enable 378/379 Supplement Digit Output  
Enable 414/419 Supplement Digit Output  
Enable 434/439 Supplement Digit Output  
0
1
2
3
4
5
6
7
EAN Supplement Control  
UPC/EAN Security Level  
The scanner offers three levels of decode security for UPC/EAN bar codes:  
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this  
security level may significantly impair the decoding ability of the scanner.  
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.  
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may  
increase the misread.  
EAN Supplement Control  
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement  
digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.  
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5  
supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.  
19  
                                                                                                                          
                                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
UCC Coupon Extended Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UCC Coupon Extended Code  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable UCC Coupon Extended Code  
Enable UCC Coupon Extended Code  
0
1
UCC Coupon Extended Code  
When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128  
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.  
20  
                                                                                                                              
                                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
IATA & Interleaved 2 of 5 Setting ♦  
PROGRAM  
Family Code Selection  
IATA Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable IATA  
Enable IATA  
0
1
2
3
4
5
6
7
8
9
A
B
C
Select 15-digit fixed length IATA checking  
Select variable length IATA  
Disable check digit verification  
Enable check digit automatic verification  
Enable S/N checking digit verification only  
Enable CPN checking digit verification only  
Enable CPN, Airline and S/N check digit verification  
Disable check digit transmission  
Enable check digit transmission  
Disable start/stop symbol transmission  
Enable start/stop symbol transmission  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Interleaved 2 of 5  
0
1
2
3
4
5
6
7
8
Interleaved 2 of 5 Setting  
Enable Interleaved 2 of 5  
Select Interleaved 2 of 5 as primary format  
Select German Postal Code as primary format  
No check character  
Validate USS check digit  
Validate OPCC check digit  
Disable check digit transmission  
Enable check digit transmission  
21  
                                                                                                                                       
                                                                                                                                                                                        
Configure Your FuzzyScan  
Symbology Reading Control  
Code 25 Family Setting ♦  
PROGRAM  
Family Code Selection  
Code 25 Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Standard/Industrial 2 of 5  
Enable Standard/Industrial 2 of 5  
0
1
2
3
4
5
6
7
8
9
Disable Matrix 2 of 5  
Enable Matrix 2 of 5  
Disable China Postal Code  
Enable China Postal Code  
Disable check digit verification  
Enable check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Code 25 Family Min. Length  
Code 25 Family Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable  
length of Code 25 will increase the possibility of reading error.  
22  
                                                                                                                                    
                                                                                                                                                                                            
Configure Your FuzzyScan  
Symbology Reading Control  
Code 11 & Code 93 Setting ♦  
PROGRAM  
Family Code Selection  
Code 11 Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 11  
Enable Code 11  
0
1
2
3
4
5
6
Disable check digit verification  
Select 1-check digit verification  
Select 2-check digit verification  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Code 11 Min. Length  
Code 11 Max. Length  
Code 93 Setting  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
SS  
SS  
SS  
Disable Code 93  
Enable Code 93  
Disable check digit transmission  
Enable check digit transmission  
0
1
2
3
SS  
MS  
Default (01)  
FIN  
(2 digits)  
Code 93 Min. Length  
Code 93 Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
23  
                                                                                                                                          
                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
MSI/Plessey Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
MSI/Plessey Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable MSI/Plessy  
Enable MSI/Plessy  
0
1
2
3
4
5
6
Select MOD 10 check digit  
Select MOD 10-10 check digit  
Select MOD 11-10 check digit  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
MSI/Plessey Min. Length  
MSI/Plessey Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
24  
                                                                                                                             
                                                                                                                                                                                                  
Configure Your FuzzyScan  
Symbology Reading Control  
Code 128 & UCC/EAN 128 Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 128/EAN-128 Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Code 128 and GS1-128  
0
1
2
3
4
5
Enable Code 128 and GS1-128  
Disable function code conversion  
Enable function code conversion  
ISBT Concatenation Off  
ISBT Concatenation On  
SS  
MS  
Default (01)  
FIN  
(2 digits)  
Code 128/EAN-128 Min. Length  
Code 128/EAN-128 Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
25  
                                                                                                                                           
                                                                                                                                                                                     
Configure Your FuzzyScan  
Symbology Reading Control  
UK/Plessey Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
UK/Plessey Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable UK/Plessey  
Enable UK/Plessey  
0
1
2
3
4
5
6
7
Select UK/Plessey Standard Format  
Select UK/Plessey CLSI Format  
Disable Convert X to A-F  
Enable Convert X to A-F  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
UK/Plessey Min. Length  
UK/Plessey Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
26  
                                                                                                                                              
                                                                                                                                                                                 
Configure Your FuzzyScan  
Symbology Reading Control  
Telepen Setting ♦  
PROGRAM  
Family Code Selection  
Telepen Setting  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable Telepen  
Enable Telepen  
0
1
2
3
4
5
Select Telepen Numeric mode  
Select Telepen Full ASCII mode  
Disable check digit transmission  
Enable check digit transmission  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
Telepen Min. Length  
Telepen Max. Length  
01-Maximum  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (98)  
98-Minimum  
FIN  
(2 digits)  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
27  
                                                                                                                                          
                                                                                                                                                                                      
Configure Your FuzzyScan  
Symbology Reading Control  
GS1 DataBar Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
GS1 DataBar Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
Disable GS1 DataBar (RSS-14)  
0
1
2
3
4
5
Enable GS1 DataBar (RSS-14)  
Disable GS1 DataBar Limited  
Enable GS1 DataBar Limited  
Disable GS1 DataBar Expanded  
Enable GS1 DataBar Expanded  
SS  
MS  
Default (04)  
FIN  
(2 digits)  
GS1 DataBar Min. Length  
GS1 DataBar Max. Length  
01-Maximum  
Only available for Expanded GS1 Databar.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
Default (74)  
74-Minimum  
FIN  
(2 digits)  
Only available for Expanded GS1 Databar.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
28  
                                                                                                                     
                                                                                                                                                                                                           
Configure Your FuzzyScan  
Symbology Reading Control  
Linear-stacked & Korea Post Code Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Composite Codes Setting  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
Disable composite codes  
Enable composite codes  
0
1
2
3
UPC Composite Mode: UPC never linked  
UPC Composite Mode: UPC always linked  
SS  
SS  
SS  
SS  
Disable PDF417  
Enable PDF417  
Disable MicroPDF417  
Enable MicroPDF417  
0
1
2
3
PDF417/Micro PDF417 Setting  
Codablock F Setting  
SS  
SS  
Disable  
Enable  
0
1
SS  
SS  
Disable  
Enable  
0
1
Korea Post Code Setting  
Length fixed in 6 characters.  
Composite Codes Setting  
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.  
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.  
29  
                                                                                                                          
                                                                                                                                                                                                     
Configure Your FuzzyScan  
Keyboard Interface Control  
Keyboard Layout (Language) Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Keyboard Layout  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
USA (QWERTY)  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
France (AZERTY)  
Germany (QWERTZ)  
United Kingdom - UK (QWERTY)  
Canadian French (QWERTY)  
Spain (Spanish, QWERTY)  
Sweden/Finland (QWERTY)  
Portugal (QWERTY)  
Norway (QWERTY)  
Spain (Latin America, QWERTY)  
Italy (QWERTY)  
Netherlands (QWERTY)  
Denmark (QWERTY)  
Belgium (AZERTY)  
Switzerland-Germany (QWERTY)  
Iceland (QWERTY)  
Japan (DOS/V)  
Czech (QWERTY)  
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.  
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.  
Keyboard Interface Message String :  
Preamble  
Data Length  
2-3 digits  
Prefix Symbol ID  
1 or 2 characters  
Scanned Data  
Suffix Symbol ID  
1 or 2 characters  
Postamble  
Record Suffix  
1 character  
1-15 characters  
Variable length  
1-15 characters  
30  
                                                                                                              
                                                                                                                                                                                                                 
Configure Your FuzzyScan  
Keyboard Interface Control  
Record Suffix, Preamble, Postamble & Caps Lock ♦  
PROGRAM  
Family Code Selection  
Record Suffix  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
None  
RETURN  
TAB  
0
1
2
3
4
SPACE  
ENTER (Numeric Key Pad)  
User defined character (1 character)  
5, (00-7F)  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Preamble  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
SS  
SS  
“Caps Lock Off” State  
“Caps Lock On” State  
0
1
2
Caps Lock Control  
Caps Lock Release Control  
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)  
SS  
SS  
“Caps Lock On, Caps Off”  
“Caps Lock On, Shift Off”  
0
1
The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.  
While selecting the other host interfaces, these selections don’t perform the above functions for you.  
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will  
perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission  
handshaking without changing the status of Caps Lock switch.  
31  
                                                                                                                                                 
                                                                                                                                                                               
Configure Your FuzzyScan  
Keyboard Interface Control  
Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Intermessage Delay  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
Intercharacter Delay  
Interfunction Delay  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.  
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data  
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)  
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two  
parameters.  
Interfunction Delay is a time delay between the transmission of each segment of the message string.  
32  
                                                                                                                 
                                                                                                                                                                                                               
Configure Your FuzzyScan  
Keyboard Interface Control  
Emulation Setting & Upper/Lower Case Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Function Key Emulation  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Enable ASCII 00-31 code as keyboard function code output  
Ctrl-Output  
0
1
Refer to Appendix – Keyboard Function Code Table for details.  
SS  
SS  
Disable key pad emulation  
0
1
Key Pad Emulation  
Upper/Lower Case  
Enable numeric output as key pad (Num Lock On) output  
SS  
SS  
SS  
SS  
Normal case (neglect the upper/lower case control)  
0
1
2
3
Inverse case (change all characters output to inverse case)  
Upper case (force all characters output as upper case)  
Lower case (force all characters output as lower case)  
33  
                                                                                                                    
                                                                                                                                                                                                            
Configure Your FuzzyScan  
Serial Interface Control  
Record Suffix, Preamble ,Postamble Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
STX/ETX Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable STX/ETX transmission  
Enable STX/ETX transmission  
0
1
STX/ETX are two characters used to indicate the starting and ending of the total  
data frame transmitted via serial interface.  
SS  
SS  
SS  
SS  
SS  
SS  
MS  
None  
CR (0DH)  
LF (0AH)  
CRLF (0D0AH)  
TAB (09H)  
0
1
2
3
4
5
Record Suffix  
SPACE (20H)  
User defined character (1 character)  
6, (00-7F)  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Preamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
Serial Interface Message String (RS232, USB COM) :  
STX  
Preamble  
Data Length  
2-3 digits  
Prefix Symbol ID Scanned Data  
Suffix Symbol ID  
Postamble  
ETX  
Record Suffix  
1 character  
1 character  
1-15 characters  
1 or 2 characters Variable length 1 or 2 characters 1-15 characters  
1 character  
34  
                                                                                                                                                 
                                                                                                                                                                               
Configure Your FuzzyScan  
Serial Interface Control  
Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Intermessage Delay  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
Intercharacter Delay  
Interfunction Delay  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
SS  
MS  
None  
FIN  
(2 digits)  
1-99 (x5) msec.  
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate  
this selection automatically.  
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.  
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data  
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)  
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two  
parameters.  
Interfunction Delay is a time delay between the transmission of each segment of the message string.  
35  
                                                                                                                                   
                                                                                                                                                                                            
Configure Your FuzzyScan  
Serial Interface Control  
Protocol, ACK/NAK Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Handshaking Protocol  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
None (free running mode)  
0
1
2
3
RTS/CTS (hardware handshaking)  
ACK/NAK (software handshaking)  
Xon/Xoff (software handshaking)  
SS  
SS  
3 times  
FIN  
(3 digits)  
NAK Retry Count  
ACK Indication  
0~255 times  
SS  
SS  
SS  
SS  
Disable ACK Time-out Indication  
Enable ACK Time-out Indication  
Disable ACK Indication  
Enable ACK Indication  
0
1
2
3
USB COM doesn’t support RTS/CTS handshaking protocol.  
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after  
each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.’  
NAK Retry Count  
After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner  
will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner  
issues an error indication and discards the data under following two conditions:  
1) After preset NAK retry counts is received within the preset serial response time-out.  
2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end.  
The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard  
the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.  
This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.  
ACK Indication:  
Disable: There’s neither LED nor beeping indication for this setting.  
Enable: There’s a specific LED and beeping indication for this setting.  
36  
                                                                                                                       
                                                                                                                                                                                                         
Configure Your FuzzyScan  
Serial Interface Control  
Time Out Setting, Baud Rate, Data Frame ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Serial Response Time-out  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
None  
3 seconds  
4 seconds  
5 seconds  
8 seconds  
10 seconds  
15 seconds  
0
1
2
3
4
5
6
7
8
9
A
B
200 mseconds  
500 mseconds  
800 mseconds  
1 second  
2 seconds  
SS  
SS  
SS  
SS  
38.4K BPS  
19.2K BPS  
2400 BPS  
1200 BPS  
57.6K BPS  
115.2K BPS  
0
1
2
3
4
5
8
9
Baud Rate (BPS)  
Data Frame  
9600 BPS  
4800 BPS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
8, None, 1  
8, Odd, 1  
8, Even, 1  
8, Space, 1  
8, Mark, 1  
8, None, 2  
7, Odd, 1  
7, Space, 1  
7, Mark, 1  
7, None, 2  
7, Odd, 2  
7, Even, 2  
7, Space, 2  
7, Mark, 2  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
7, Even, 1  
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data  
communication. This option is very helpful to ensure the reliability of data communication.  
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.  
37  
                                                                                                                                  
                                                                                                                                                                                              
Configure Your FuzzyScan  
Wand/Laser Emulation Control  
Code 39/Code 128 Emulation ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Code 39/Code 128 Emulation  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
Disable standard Code 39 emulation  
0
1
2
3
4
Enable standard Code 39 skip emulation  
Enable standard Code 39 replace emulation  
Enable Full ASCII Code 39 emulation  
Enable Code 128 emulation  
[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,  
they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.  
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.  
38  
                                                                                                                                       
                                                                                                                                                                                         
Configure Your FuzzyScan  
Operation Control  
Operation Mode Setting ♦  
PROGRAM  
Family Code Selection  
Operation Mode  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
Low Power mode  
Force mode  
Toggle mode  
Diagnostic mode  
Level mode  
L680/L780 laser imagers don’t support:  
Flash/ Force/ Toggle/ Diagnostic mode.  
0
1
2
3
4
5
6
7
8
Trigger mode  
Presentation mode  
Alternative mode  
Flash mode  
SS  
SS  
SS  
Presentation mode  
Flash mode  
Force mode  
0
1
2
Presentation Control  
L680/L780 laser imagers don’t support this function.  
Low Power Mode (Low Power Triggering) The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation.  
It is very helpful for mobile data collection and application, which are concerned with power saving.  
Trigger Mode (External Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner  
before scanning the bar code.  
Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is  
similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work  
properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “Presentation Sensitivity”).  
Alternative Mode (Periodic Power Off) The scanner keeps the light source of the scanner turned on till the pre-defined light source on time is up. After the scanner turns  
off the light source, you must press the trigger to turn on the light source again. After each good read, the timer counter of “Light Source on Time” is reset. You do not have  
to press the trigger frequently, it is very convenient for multiple scanning.  
Flash Mode (Pulse Driven Reading) The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar  
code, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.  
Force Mode (Continued Power On) The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for  
high speed bar code reading.  
Toggle Mode (Repeat Reading) The toggle mode is very similar to the Alternative Mode but without the pre-defined light source on time concern. You must press the  
trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again.  
Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the  
scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.  
Level Mode (Auto Power Off) When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined  
“Light Source on Time”. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press  
the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after  
the pre-defined light source on time is up.  
Presentation Control When the scanner is placed on SmartStand, the scanner will be switched from hand-held scanning to hands free scanning automatically. Three  
hands scanning modes are available. You are recommended to use flash mode or force mode while under insufficient ambient light.  
Only Low power mode, Trigger mode, Presentation mode and Level mode are available for FuzzyScan Laser model.  
39  
                                                                                                                    
                                                                                                                                                                                                            
Configure Your FuzzyScan  
Operation Control  
Buzzer, Indicator, Vibrator, Inverse Reading ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Buzzer Tone Adjust  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Buzzer tone – mute  
Buzzer tone – low  
Buzzer tone – medium  
Buzzer tone – high  
0
1
2
3
4
5
6
Buzzer tone - extremely high  
Power-on beep  
No power-on beep  
SS  
SS  
SS  
Disable (LED off)  
0
1
2
Power On Indicator  
Good Read Indicator  
Vibrator Control  
LED steady on  
LED flash  
SS  
SS  
Disable  
0
1
Enable  
SS  
SS  
Disable  
Enable  
0
1
Optional function, only available for vibrator model.  
SS  
SS  
Disable  
Enable  
0
1
Inverse Reading  
40  
                                                                                                                    
                                                                                                                                                                                                            
Configure Your FuzzyScan  
Operation Control  
Dollar Sign, Redundancy, Scan Rate Control♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Dollar Sign Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
SS  
Dollar sign output as “ $ “  
0
1
2
3
4
Dollar sign output as “  
Dollar sign output as “ € “  
Dollar sign output as “ £ “  
Dollar sign output as “ ¢ “  
SS  
SS  
SS  
SS  
SS  
SS  
None  
0
1
2
3
4
5
Redundancy  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
To prevent potential miss reading.  
SS  
SS  
Dynamic  
Fixed  
0
1
Scan Rate Control  
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.  
Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on  
the move. But this may impact to the reading distance.  
41  
                                                                                                                               
                                                                                                                                                                                                
Configure Your FuzzyScan  
Operation Control  
Flash Duty Cycle, Delay Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Flash Duty Cycle  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
SS  
1/2 duty cycle  
2/3 duty cycle  
3/4 duty cycle  
4/5 duty cycle  
0
1
2
3
L680/L780 laser imagers don’t support this function.  
Reread Delay  
(DoubleScan Verification)  
SS  
SS  
SS  
SS  
SS  
SS  
Disable  
Immediate time out  
Short time out  
Medium time out  
Long time out  
Force verification  
0
1
2
3
4
5
SS  
SS  
SS  
SS  
SS  
SS  
SS  
None  
0
1
2
3
4
5
6
Good Read Delay  
200 msec.  
500 msec.  
1 sec.  
1.5 sec.  
2 sec.  
3 sec.  
The Flash Duty Cycle is designed to control the flashing frequency of the light source.  
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification  
will not allow reading of the same bar code twice.  
This Good Read Delay is the minimum amount of time before the imager can read another bar code.  
42  
                                                                                                                         
                                                                                                                                                                                                       
Configure Your FuzzyScan  
Operation Control  
Time-out Setting, Good Read Duration ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Light Source On Time  
P.C  
Parameter Selection  
Option Code  
Medium  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
Long  
Extremely long  
Medium  
SS  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
4
Hands Free Time-out  
Good Read Duration  
Long  
Extremely long  
Disable  
SS  
SS  
SS  
SS  
SS  
Short  
0
1
2
3
4
Medium  
Long  
Extremely long  
Extremely short  
SS  
SS  
SS  
SS  
SS  
SS  
1 sec  
0
1
2
3
4
5
Time Delay to Low Power Mode  
3 secs  
5 secs  
7 secs  
9 secs  
Immediate  
The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on  
till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.  
The Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode  
when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any  
trigger operation), the imager will revert to the original hands free mode.  
The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity. This setting is only available for the scanner is in low  
power mode.  
43  
                                                                                                                 
                                                                                                                                                                                                               
Configure Your FuzzyScan  
Operation Control  
Presentation Scanning Setting , Trigger Control♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
SmartStand Power Off Timeout  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
SS  
3 mins  
5 mins  
0
1
2
10 mins  
Only available for FuuzzyScan Laser model  
Disable  
SS  
SS  
0
1
Presentation Auto-sense  
Presentation Sensitivity  
Trigger Control  
Enable  
SS  
SS  
SS  
SS  
SS  
Level 1  
Level 2  
Level 3  
Level 4  
Level 5  
Level 6  
Level 7  
0
1
2
3
4
5
6
SS  
SS  
SS  
Enable left trigger, disable right trigger  
Enable right trigger, disable left trigger  
0
1
2
Enable left and right triggers  
Only available for FuzzyScan F460/F468  
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on  
SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be  
off when the pre-defined duration is up.  
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the  
SmartStand.  
The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting  
the barcode.  
44  
                                                                                                                                         
                                                                                                                                                                                      
Configure Your FuzzyScan  
Operation Control  
Laser Aiming Control♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Laser Aiming Control  
P.C  
Parameter Selection  
Option Code  
SS  
SS  
Disable  
Enable  
0
1
Only available for L series laser imaging scanner.  
You can disable or enable laser aiming line when you scan PDF barcode.  
45  
                                                                                                         
                                                                                                                                                                                                                      
Configure Your FuzzyScan  
Condensed DataWizard  
Preamble, Postamble, Data Length & Symbol ID Trans. ♦  
PROGRAM  
Family Code Selection  
Preamble  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
MS  
None  
FIN  
[00-7F], [FIN]  
Postamble  
1-15 characters  
Maximum 15-character input; scan “FIN” to terminate this selection.  
SS  
SS  
Disable  
0
1
Data Length Transmission  
Symbology ID Transmission  
Enable 2 digits data length transmission  
If data length exceeds 99, 3-digit data length will be transmitted.  
SS  
SS  
SS  
SS  
SS  
SS  
SS  
Disable symbology ID transmission  
Enable prefix symbology ID transmission  
Enable suffix symbology ID transmission  
Enable both prefix and suffix symbology ID transmission  
Enable prefix AIM symbology ID transmission  
Enable suffix AIM symbology ID transmission  
Enable both prefix and suffix AIM symbology ID transmission  
0
1
2
3
4
5
6
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,  
you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help  
you to arrange the transmission of scanned data to any specific format without software modification.  
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done  
on-screen, under Windows 95/98/NT/2000/XP environment.  
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with  
ease.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.  
46  
                                                                                                                                       
                                                                                                                                                                                       
Configure Your FuzzyScan  
Condensed DataWizard  
Data Formatter Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Formatter Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Insertion  
2nd Insertion  
3rd Insertion  
4th Insertion  
[1-3 characters], [FIN]  
[1-3 characters], [FIN]  
[1-3 characters], [FIN]  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; max. 3 insertion characters  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
[1-3 characters], [FIN]  
2-digits identified position; max. 3 insertion characters  
position  
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.  
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.  
All of the above programmable parameters perform the same function depending on your setting.  
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 45 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
47  
                                                                                                                                         
                                                                                                                                                                                     
Configure Your FuzzyScan  
Condensed DataWizard  
Data Verifier Setting ♦  
PROGRAM  
Family Code Selection  
Verifier Control  
F_DEFAULT  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
Identified Data Length  
1st Identified Character  
2nd Identified Character  
3rd Identified Character  
Determine the identified data length for verification.  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
[00-7F]  
[00-7F]  
[00-7F]  
2-digits checking position; 1 identified character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits checking position; 1 identified character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits checking position; 1 identified character  
position  
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.  
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the  
FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.  
The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 45 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
48  
                                                                                                                                        
                                                                                                                                                                                      
Configure Your FuzzyScan  
Condensed DataWizard  
Data Replacer Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Replacer Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Replacement  
2nd Replacement  
3rd Replacement  
[00-7F]  
[00-7F]  
[00-7F]  
2-digits identified position; 1 replacement character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; 1 replacement character  
position  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
2-digits identified position; 1 replacement character  
position  
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for replacer control, and provides Multiple Position Replacement in the identified position.  
All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it  
arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 45 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.  
49  
                                                                                                                                       
                                                                                                                                                                                       
Configure Your FuzzyScan  
Condensed DataWizard  
Data Organizer Setting ♦  
PROGRAM  
F_DEFAULT  
Family Code Selection  
Organizer Control  
P.C  
Parameter Selection  
Option Code  
2nd Option Code  
SS  
MS  
MS  
Disable  
FIN  
(2 digits)  
00  
Select one bar code symbology  
Select all bar code symbologies  
automatic termination  
automatic termination  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
1st Organization  
2nd Organization  
0 (Forward)  
1 (Backward)  
2-digits identified position;  
Forward/backward data transmission setting  
position  
direction  
SS  
DS  
Disable  
Enable  
FIN  
(2 digits)  
0 (Forward)  
1 (Backward)  
2-digits identified position;  
Forward/backward data transmission setting  
position  
direction  
SS  
DS  
Transmitted data excluded the data of identified position  
Transmitted data included the data of identified position  
0
1
Include/Exclude Control  
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code  
symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data  
including or excluding the data of identification position. Please refer to the application example listed in page 45 for details.  
While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record  
Suffix.  
Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 45 for details.  
Please note that all “Character” input should be referred to the ASCII/HEX Table.  
50  
Configure Your FuzzyScan  
[Data Verifier, Data Replacer, Data Organizer]  
Select a Bar Code Symbology  
If there is a 11-character data string, please refer to the  
following to calculate the actual position for identification.  
You can select one or all types of bar code symbologies to  
use Condensed DataWizard for advanced transmission  
arrangement. If you scan “00” to select all types, the  
FuzzyScan will arrange all incoming data to meet your  
pre-defined format. If you want to select only one type bar  
code, please select one of the option code listed below.  
X
X
X
X
X
X
X
X
X
X
X
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
Application Example  
Code 128 : 01  
EAN-8 : 05  
Code 93 : 09  
If your bar code label is a 16-digit Interleaved 2 of 5 which  
includes the information of 6-digit date code, 6-digit serial  
number and 4-digit unit price, you want the FuzzyScan do  
the following for you without software modification:  
UCC/EAN 128 : 31  
UPC-A : 02  
EAN-8 with 2 supple : 35  
EAN-8 with 5 supple.: 45  
Codabar/NW-7 : 06  
Code 39 : 07  
Code 11 : 10  
MSI/Plessey : 11  
UK/Plessey : 12  
Telepen : 13  
UPC-A with 2 supple.: 32  
UPC-A with 5 supple.: 42  
UPC-E : 03  
Code 32 : 37  
GS1 Data Bar : 14  
IATA : 15  
Apply only Interleaved 2 of 5 to the condensed  
UPC-E with 2 supple.: 33  
UPC-E with 5 supple.: 43  
EAN-13 : 04  
Trioptic Code 39: 47  
Matrix 2 of 5 : 38  
Interleaved 2 of 5 : 48  
DataWizard.  
Coupon Code : 16  
PDF417/Micro PDF417: 22  
Codablock: 23  
Check bar code is actually with 16-digit length.  
EAN-13 with 2 supple. : 34 China Postal Code : 58  
EAN-13 with 5 supple. : 44 German Postal Code : 68  
Allow bar code output whose date code is leading with  
Korea Post Code: 26  
“9”.  
Position Calculation  
[Data Formatter]  
Three outputs with “TAB” suffix.  
The date code output should skip “9” and replaced it by  
“A”.  
If there is a 5-character input data string, refer to the following  
to calculate the actual position for insertion:  
The serial number output should be led with “SN”.  
X
X
X
X
X
The unit price output should be skipped the first 2  
00  
01  
02  
03  
04  
05  
digits.  
Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6  
Actual Output : A81025[TAB]SN123456[TAB]76[TAB]  
51  
Configure Your FuzzyScan  
Programming Procedure  
[Data Verifier]  
[Data Replacer]  
Scan “Program” to enter the programming mode.  
Scan “Replacer Control” and set bar code symbology  
to “48”.  
Scan “Verifier Control” and set bar code symbology to “48”  
(Interleaved 2 of 5).  
Scan “1st Replacement” and set the identified position  
to “00”, then replaced character to “41” (Hex Code of  
Scan “Identified Data Length” and set the length to “16”.  
A).  
Scan “1st Identified Character” and set the identified  
position to “00”, then set the identified character to “39”  
(Hex Code of 9).  
[Data Organizer]  
Scan “Organizer Control” and set bar code symbology  
to “48”.  
[Data Formatter]  
Scan “Formatter Control” and set bar code symbology to Scan “1st Organization” and set the identified position  
48”. to 16”, then set the data transmission to “0” (forward).  
Scan 1st Insertion” and set the identified position to “06”, Scan “2nd Organization” and set the identified position  
then inserted characters to “09” (Hex Code of TAB), “53”  
(Hex Code of S), “4E” (Hex Code of N).  
to “17”, then set the data transmission to “1”  
(backward).  
Scan “2nd Insertion” and set the identified position to “12”,  
then inserted character to “09”. In the final, you must scan  
FIN” (Finish) code to terminate this selection.  
Scan “END” (Exit) to terminate the programming.  
[Important Notice]  
Scan “3rd Insertion” and set the identified position to “16”,  
then inserted character to “09”. In the final, you must scan  
FIN” (Finish) code to terminate this selection.  
Please note that Condensed DataWizard will follow the  
preset working flow as below:  
Verifier  
Formatter  
Replacer  
Organizer  
So when you set the identified position in Data Organizer,  
you must consider the inserted data which you already set  
via Data Formatter.  
52  
Appendix  
Symbology ID Table  
Each AIM Code Identifier contains the three-character string ]cm where:  
] = Flag Character  
c = Code Character  
m = Modifier Character  
Cino ID  
AIM ID  
Cino ID  
AIM ID  
Code Family  
Primary Format  
Code Family  
Primary Format  
Code  
Code  
Modified  
Code  
Code  
Modified  
Character  
Character  
Character  
Character  
Character  
Character  
UPC-A  
m
1
EAN/JAN-8  
4
1
A
E
N
F
E
UPC-A with 2 supple.  
UPC-A with 5 supple.  
UPC-E  
EAN/JAN-8 with 2 supple.  
EAN/JAN-8 with 5 supple.  
EAN/JAN-13  
2
2
E
m
1
m
1
UPC  
EAN/JAN  
E
UPC-E with 2 supple.  
UPC-E with 5 supple.  
EAN/JAN-13 with 2 supple.  
EAN/JAN-13 with 5 supple.  
2
2
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is  
transmitted as ]E0012345678950]E112  
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is  
transmitted as ]E449123562]E212345  
Code 128  
B
C
D
I
m
1
Code 93  
Code 93  
H
P
R
S
T
G
H
M
P
m
m
m
0
Code 128  
Codabar  
C
GS1-128  
Code 11  
Code 11  
Codabar/NW-7  
Standard/Industrial 2 of 5  
Matrix 2 of 5  
F
S
X
I
m
0
MSI/Plessey  
UK/Plessey  
Telepen  
MSI/Plessey  
UK/Plessey  
Telepen  
K
J
0
B
m
Interleaved 2 of 5  
m
GS1 DataBar GS1 Databar  
Code 25  
X
e
0
Composite  
Composite Code  
Code 39  
China Postal Code  
L
X
0
G
W
G
V
A
X
A
L
m
0
0
0
0
0
Code 39  
German Postal Code  
IATA  
M
O
Z
I
3
Code 39 Trioptic  
Code 32  
IATA  
R
m
UCC Coupon Code  
PDF417  
PDF417/Micro PDF417  
Codablock F  
Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar  
code is transmitted as]E0512345678900]C181010123451297  
Example: A EAN-13 9923456789019 + GS1-128 81010123451297 bar  
code is transmitted as ]E09923456789019]C181010123451297  
Codablock  
Korea Post  
Y
O
X
UCC Coupon  
Korea Post Code  
a
Remark: Above examples are given for the transmission of AIM ID.  
53  
Appendix  
Keyboard Function Code Table  
No.  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
ANSI  
NUL  
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
ASCII  
00H  
01H  
02H  
03H  
04H  
05H  
06H  
07H  
08H  
09H  
0AH  
0BH  
0CH  
0DH  
0EH  
0FH  
Key Function  
No.  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
ANSI  
DLE  
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
ETB  
CAN  
EM  
ASCII  
10H  
11H  
Key Function  
RESERVED  
CTRL (Left)  
ALT (Left)  
SHIFT  
F7  
F8  
12H  
13H  
14H  
15H  
16H  
17H  
18H  
19H  
1AH  
1BH  
1CH  
1DH  
1EH  
1FH  
F9  
F10  
F11  
F12  
CAPS LOCK  
NUM LOCK  
ESC  
INS (Insert) (Edit)  
DEL (Delete) (Edit)  
HOME (Edit)  
F1  
BACK SPACE  
HT  
TAB  
END (Edit)  
LF  
F2  
SUB  
ESC  
FS  
PAGE UP (Edit)  
PAGE DOWN (Edit)  
UP (Edit)  
VT  
F3  
12  
13  
14  
15  
FF  
F4  
CR  
ENTER (CR)  
GS  
DOWN (Edit)  
LEFT (Edit)  
SO  
F5  
F6  
RS  
SI  
US  
RIGHT (Edit)  
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the  
Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done  
by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,  
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.  
54  
Appendix  
ASCII Input Shortcut  
To configure the user definable parameters of FuzzyScan via  
programming menu, FuzzyScan will ask you to scan your  
desired ASCII value in HEX form. You have to refer to the  
HEX/ASCII Table” for details.  
HEX/ASCII Reference Table  
H
0
1
2
3
4
5
6
7
L
0
1
NUL  
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
DLE SPACE  
0
1
2
3
4
5
6
7
8
9
:
@
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
`
a
b
c
d
e
f
p
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
ETB  
CAN  
EM  
!
"
q
Example:  
2
r
If you want the scanned data output leading with a Dollar  
Sign, you have to set the “Preamble” to “$”. The configuration  
procedure is listed below for reference.  
3
#
$
%
&
'
s
4
t
5
u
Scan the system command – PROGRAM listed on page  
6
v
3-24 to enter programming mode.  
7
G
H
I
g
h
i
w
Scan family code – PREAMBLE to select this family.  
8
(
x
9
HT  
)
y
Refer to the Hex/ASCII Table, you will find the HEX value  
of “$” is 24.  
A
B
C
D
E
F
LF  
SUB  
ESC  
FS  
*
J
j
z
VT  
+
,
;
K
L
k
l
{
Scan the option code – 2 listed on the fold out back cover.  
Scan the option code – 4 listed on the fold out back cover.  
FF  
<
=
>
?
\
|
}
CR  
GS  
-
M
N
O
]
m
n
o
Scan the system command – FIN (Finish) to terminate  
SO  
RS  
.
^
~
Preamble setting.  
SI  
US  
/
_
DEL  
Scan the system command – End to exit the programming  
Example : ASCII “A” HEX “41”; ASCII “a” “61”  
: High Byte of HEX Value  
mode for normal operation.  
: Low Byte of HEX Value  
55  
Appendix  
Host Interface Quick Set  
RS232 Serial  
PS/2 (DOS/V) KBW Standard Mode  
USB HID Standard Mode  
Keyboard Replacement  
PS/2 (DOS/V) KBW Turbo Mode  
USB HID Turbo Mode  
USB Com Port Emulation  
56  
Appendix  
Operation Mode Quick Set  
Low Power (Low power trigger)  
Force (Continued power on)  
Toggle (Repeat reading)  
Diagnostic (Test reading)  
Alternative (Periodic power off)  
Flash (Pulse driven reading)  
Level (Auto power off)  
Trigger (External triggering)  
Presentation (Auto sensing)  
57  
Appendix  
Option Codes  
0
1
2
3
8
9
4
5
6
7
C
D
E
F
A
B
FIN (Finish)  
END (Exit)  
58  
Appendix  
System Commands  
PROGRAM  
(Enter Programming Mode)  
System Information List  
(SYSLIST)  
Save User Default  
FIN (Finish)  
PowerTool Host Link  
User Default  
END  
(Exit Programming Mode)  
Factory Default  
Master Default  
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.  
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface  
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation  
Control, the rest of parameters will be returned to default value.  
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and  
would like to return to previous setting, please scan “User Default”.  
59  

Briggs Stratton 311700 User Manual
Brother FAX 2840 User Manual
Cecilware Liquid Iced Tea Dispenser TT4 User Manual
Cino FUZZYSCAN L700 User Manual
Epson STYLUS NX410 User Manual
Epson Stylus SX420W User Manual
Friedrich MR24C3G User Manual
Friedrich SC06 User Manual
Honda Automobiles Backup Sensors RL User Manual
HP Hewlett Packard Officejet J4660 User Manual