Carrier 50TFF004 014 User Manual

50TFF-4SB  
50TFF004-014  
SINGLE-PACKAGE ELECTRIC  
COOLING UNITS WITH  
FIELD-INSTALLED ELECTRIC HEAT  
— PERFORMANCE DATA  
— CERTIFIED DIMENSION PRINTS  
— CERTIFIED ROOF CURB  
DIMENSION PRINTS  
© Copyright 2005 Carrier Corporation • Syracuse, New York 13221  
Form 50TFF-4SB  
Replaces: 50TFF-3SB  
Printed in U.S.A.  
11-05  
Catalog No. 04-51500003-01  
OPTIONS AND ACCESSORIES  
FACTORY-INSTALLED OPTIONS  
EconoMi$er IV with Controller  
Non-Fused Disconnect Switch (factory wired)  
115-Volt Convenience Outlet (factory wired, load side)  
PremierLink Control  
EconoMi$er2 with 4-20 mA Actuator Only  
(PremierLink™ or 3rd Party EMS System  
Control)  
25% Manual Air Damper  
Copper/Copper Coils — Evaporator,  
Condenser, Both  
Pre-Coated Condenser Coil  
E-Coat (Post-Coated) Condenser Coil  
Alternate Motor and Drive  
(except 007 and 009 size)  
High-Static Motor (except size 014)  
Novar 3051 Control  
FIELD-INSTALLED ACCESSORIES  
EconoMi$er IV with Controller  
EconoMi$er2 with 4-20 mA Actuator and No Microproces-  
sor — Vertical or Horizontal  
PremierLink Control  
CO Sensor (IAQ Control)  
2
Power Exhaust  
25% Open Two-Position Damper  
25% Open Manual Air Damper  
50% Open Manual Outdoor Air Damper  
100% Open Two-Position Damper  
Outdoor Air/Return Air Temperature  
Sensor  
Outdoor Air/Return Air Enthalpy Sensor  
Roof Curb (14 or 24-in. Height)  
Thru-the-Bottom/Roof Curb Electrical  
Connection Kit  
Horizontal Power Exhaust Module (Single Fan)  
–20 F Motormaster® Low Ambient Control Kit  
Programmable Setback Thermostat  
Electrical Mechanical Thermostat and Subbase  
Indoor Fan/Filter Status Indicator  
Electric Resistance Heat Coils  
62AQ Energy$Recycler™ Mounting Kit  
62AQ Energy$Recycler Supply Air Blower  
62AQ Energy$Recycler 460-V Transformer  
62AQ Energy$Recycler 575-V Transformer  
Humidistat  
Time Guard II Compressor Anti-Cycle Control  
Condenser Coil Hail Guard  
Condenser Coil Grille  
Light Commercial Thermidistat™ Device  
UV-C Lamps  
Other ____________________  
Room Temperature Sensor  
BLANKET QUOTE CONTROLS  
115-Volt Field Powered GFI Convenience Outlet  
(line side)  
Low Ambient Controller (Motormaster® I)  
Smoke Detector — Return Air  
115-Volt GFI Convenience Outlet (field powered)  
E-Coated Aluminum/Copper Condenser and Evaporator Coils  
Fused Disconnect  
Hinged Acess Panels  
Lockout of High Fire Stage for Heating  
Smoke Detector — Return and Supply Air  
Smoke Detector — Supply Air  
Split Power (transfer switch NOT included)  
UV-C Lamps (installed and powered with door interlock  
switch and disconnect switch)  
3
4
5
6
7

Actron CP9087 User Manual
AllerAir 9900 User Manual
Briggs Stratton Automobile Parts 50000 User Manual
Brookstone Mobile 2600 mAh Power Charger 802217 User Manual
Brother VERSION 0 MFC 250C User Manual
Bryant 764A User Manual
BT PC Scanner User Manual
Dakota Digital LED Tail Lights for 1968 Chevelle LAT NR180 User Manual
GE ASV08FK User Manual
Honeywell MS8120S User Manual