ULTRA-2 PAF
ULTRA-2 PAFA
USE & CARE INSTRUCTIONS for ULTRA-2 COLD DRINK DISPENSER WITH PAF DISPENSER
NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual!
DISASSEMBLY & CLEANING
EMPTY ALL PRODUCT FROM THE ULTRA HOPPERS INTO A BUCKET OR CONTAINER BEFORE PROCEEDING!
1. Open the Cabinet Door and 2. Place the power switch in
allow the support arms to lock the OFF position. Slide the gate
in place. Door must remain shut on the powder hopper and
open during the entire cleaning remove the hopper. Wipe the
3. Pull the Mixing Chamber out 4. Twist the Whipper Chamber
of the Whipper Chamber.
clockwise and pull it off the
Whipper Chamber Receptacle.
procedure.
hopper tray clean of powder
residue.
5. Pull the Frother off the Motor 6. Twist Whipper Chamber Re-
Shaft. Notice the flat keyway on ceptacle clockwise and pull it off
the shaft and the matching key- the Motor Shaft. Wipe down all
way inside the Frother. It is im- inside surfaces.
portant that these two keyways
7. Slip the O-ring off the Whip- 8. Wash components in a mild
per Chamber Receptacle and solution of dish detergent using
remove the shaft seal.
a bristle brush. Rinse and dry
each item thoroughly before
reassembling.
are lined up when reassembling.
NOTE: Parts must be thoroughly
dry before adding powder to the
hopper.
(Page 1 of 4, Continued)
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
43553.0000A 07/10 ©2010 Bunn-O-Matic Corporation
ASSEMBLY
1. Replace the auger nose bush- 2. Install the hopper seal over the 3. Align the auger shafts with the 4. Install the hopper over the
ing inside the front of the hopper. flange at the rear of the cooling augers. Push the augers as far as auger and cooling drum and
drum as shown.
they will go and rotate them so slide it into place. Push down
the flat face of the auger shaft is until the hopper lock plunger
aligned with the flat face of the snaps into place.
auger nose.
5. Position the faucet seal and 6. Slide the faucet valve assem-
the return spring in the faucet bly into place on the hopper.
valve.
7. Press down on the valve to 8. Install the drip tray and cover.
compress the spring. Position
the faucet handle over the faucet
valve one side at a time and snap
into place on the hopper.
10. Slide PAF assembly forward. 11. Reassemble and install all
PAF parts. Return power switch
9. Turn ON augers and cooling NOTE: Whether liquid concen-
function to desired settings.
trate or granulated powder, all
product must be thoroughly
mixed BEFORE adding it to the
hoppers.
to the ON position. Close Door.
43553 071410
3
THOROUGH CLEANING OF THE PAF HOPPER (Once a week)
1. Open the Cabinet Door and 2. Slide the gate shut on the 3. Pull the Ejector Elbow off the 4. Remove the Wiper Blade and
allow the support arms to lock powder hopper and remove the Hopper Base. Remove the Slide Drive Gear by removing the
in place.
hopper. Remove the Cover and Gate from the Ejector Elbow.
empty the contents.
Retaining Ring from the Wiper
Blade Shaft. Remove Auger by
pulling it out the front of Hop-
per Base.
6. Wash all components in a mild
solution of dish detergent using
a bristle brush when needed.
Rinse and dry each item thor-
oughly before reassembling.
NOTE: Parts must be thoroughly
dry before adding powder to the
hopper.
5. Remove the Auger Drive Shaft
by turning the screw of the Au-
ger Drive Bracket in a clockwise
direction.
43553 071410
4
|